Operator Display & Keystrokes
The locking push is a manual push function initiated by the operator to lock the push on. There will be a 3 second prewarning before the valve will activate. The beeper will continue to beep while the valve is active. Usually the only limit is the Conveyor Push Timeout. The display will show "Lock Push: time:xxx" where xxx is the time (in seconds) remaining for the push.
In-shield Locking Push
To activate the conveyor push on only one shield the operator can press the Locking Push key (3-key). There will be a 3 second prewarning before the valve will activate. The beeper will continue to beep while the valve is active. There are two different modes of operation for this push Target Stroke or Time.
Target Stroke If parameter “Locking Push Key” is set to “For Stk”, then the conveyor push function will attempt to push to the target stroke set by parameter “Locking Push Tgt Stk”. Both of these parameters are under Configuration->Conveyor Push. Line2 will continue to show sensor values; line1 will show "# 87 LockPush tgt: 98” for example.
to make single shield push (3s prewarn)
Parameters “Locking Push Key” “Locking Push Tgt Stk”
Time If parameter “Locking Push Key” is set to “For Time” then the conveyor push function will attempt to push for a time period set by parameter “Max Time” under Configuration->Conveyor Push.
Parameter “Max Time”
Endgate Push
The operator can trigger a push of the gate shields by pressing the Bank Push key twice and then pressing start. B a n k P u s h G a t e E n d . . . p r e s s S t a r t
This only works from the first twenty shields for the Headgate and the last twenty for the Tailgate push. The active display will show "Gate Push: delta >", "Gate Push: < delta", or "Gate Push: active" as appropriate.