1 minute read

DIPPER

Next Article
RUNNING ROPES

RUNNING ROPES

A single-line automatic lubrication system applies open gear lubricant (OGL) and grease via a programmable logic controller (PLC). The system has four lube pumps (two for OGL and two for grease), each feeding individual PLC controlled circuits. Lincoln 75:1 air powered pumps are mounted on each of the two 85 gallon reservoirs. High pressure hoses with reusable fittings are utilized.

Lubrication Room

The four separately controlled lube circuits provide selective distribution frequency and quantity resulting in reduced lubricant usage and cost.

This article is from: