RIGHT CONSOLE
RIGHT CONSOLE
13. DC GROUND LOOP - A red light which indicates an armature circuit ground in the hoist, crowd, or swing motors. An alarm will be set off when the light comes on, to eliminate the alarm, stop the machine and push the LE stop button. The light(s) will remain on until the problem is corrected.
14.AUX. TRANSFORMER OVERTEMP. - Indicates a malfunction in one or more auto lube systems. Stop the machine and check the lube control panels. DO NOT operate the machine without correcting the problem.
15. MOTOR BLOWERS - Indicates one or more of the blowers on the D.C. drive motors for the hoist, swing or crowd machinery has malfunctioned. The blower(s) at fault will have to be determined.
16. FILTER FANS - Indicates a malfunction in one or both of the house air intake filter fans located on the house roof. The fan at fault will have to be determined.
17. MASTER SWITCH FAULT - A red light which indicates a problem with either or both masterswitches. An alarm will be set off when the light comes on, to eliminate the alarm, stop the machine and push the LE stop button. The light(s) will remain on until the problem is corrected.
18. CPU FAULT - (Central Processing Unit) Indicates a malfunction in the RX3I Central Processing Unit and that the machine has been shut down.
19. TEST - A gray pushbutton which tests all 11 fault lights on the right hand control module. Replace any lamp which does not turn on. These lights should be tested at the beginning of each shift.
CAUTION: In the event an announced fault is experienced in any of the fault lights, THE MACHINE MUST BE SHUT DOWN IMMEDIATELY, the fault investigated, and the problem eliminated BEFORE continuing to operate. Continued operation after a fault is announced could result in damage to the machine.
20. SILENCE - Gray pushbutton used to silence a fault alarm.