Air Conditioning High Pressure Switch
from Cat C-10 C-12 C-15 C-16 Truck Engines Electrical &Electronic Application & Installation Guide Manual
17.2.2 Slip Mode Operation will occur under the following conditions:
17.2.3 Brake Mode Operation (Fan OFF) will occur if engine rpm exceeds 2300 rpm or when all of the following conditions are met:
Slip Mode Operation for C-15 and C-16 Slip Mode Operation for C-10 and C-12
Coolant Sensor Temperature increasing > 194°F (90°C). Coolant Sensor Temperature increasing > 194°F (90°C).
NOTE: If the cooling fan is operating in Slip Mode the fan will continue to operate in Slip Mode until coolant sensor temperature is < 178°F (81°C).
Intake Air Sensor Temperature increasing > 127°F (53°C). NOTE: If the cooling fan is operating in Slip Mode the fan will continue to operate in Slip Mode until coolant sensor temperature is < 178°F (81°C).
Intake Air Sensor Temperature increasing > 127°F (53°C).
NOTE: If the cooling fan is operating in Slip Mode the fan will continue to operate in Slip Mode until intake air sensor temperature is < 34°F (1°C).
NOTE: If the cooling fan is operating in Slip Mode the fan will continue to operate in Slip Mode until intake air sensor temperature is < 34°F (1°C). *A/C High Pressure Switch Input is Open or ECM is Counting. *A/C High Pressure Switch Input is Open or ECM is Counting.
Brake Mode Operation for C-15 and C-16 Brake Mode Operation for C-10 and C-12
Coolant Sensor Temperature < 196°F (91°C). Coolant Sensor Temperature < 196°F (91°C).
NOTE: If the cooling fan is operating in Slip Mode the fan will not transition to Brake Mode until the coolant sensor temperature decreases to < 178°F (81°C).
NOTE: If the cooling fan is operating in Slip Mode the fan will not transition to Brake Mode until the coolant sensor temperature decreases to < 178°F (81°C). The fan has been ON for at least 20 seconds. The fan has been ON for at least 20 seconds.
Intake Manifold Air Temperature < 129°F (54°C). Intake Manifold Air Temperature < 129°F (54°C).
NOTE: If the cooling fan is operating in Slip Mode the fan will not transition to Brake Mode until the coolant sensor temperature decreases to < 34°F (1°C). NOTE: If the cooling fan is operating in Slip Mode the fan will not transition to Brake Mode until the coolant sensor temperature decreases to < 34°F (1°C).
Engine Retarder ON Strategy is not Active. Engine Retarder ON Strategy is not Active.
A/C High Pressure Switch not Active. A/C High Pressure Switch not Active.
PTO On/Off Switch in OFF Position. PTO On/Off Switch in OFF Position.
Manual Fan Override Switch in OFF position Manual Fan Override Switch in OFF position
17.3 Air Conditioning High Pressure Switch
Input #11 to the ECM is available for connection of a normally closed high pressure A/C switch. The ECM has a timer available to prevent excessive cycling of the cooling fan clutch due to successive cycling of the A/C switch input. The timer is programmable from 0 to 600 seconds, with 0 seconds indicating the feature is OFF (the default). Typical programming is 30 seconds, with 1 second recommended for systems connecting this input to other controls with their own built in timers.
HighPress.
LowPress.
Refrigerant Pressure
SwitchOpen
SwitchClosed
FanOn
FanOff
A/CPressure SwitchCircuit
CoolingFan
A/C Fan Switch On Time
Output#5On
Output#5Off
Output#5
Output#4On
Output#4Off
*Output #4
*Output #4 only used when Fan Control Type is programmed to Three Speed Fan
Figure 33 - A/C High Pressure Switch Operation
OEM provided and installed components required: 1) Normally closed high pressure A/C switch. 2) Cooling fan connection to Output #5, and Output #4 (if Fan Control Type is programmed to On-Off or Three Speed Fan). Customer Parameter programming required: 1) Fan Control Type programmed to On-Off or Three Speed Fan. 2) A/C Pressure Switch Fan-On Time programmed in the 1 - 600 second range (0 = disabled).
17.3.1 A/C High Pressure Switch Operation
This switch must be a normally closed switch, opening when the refrigerant pressure exceeds the desired level. The ECM input is monitored only if the Customer Programmable Parameter for A/C Pressure Fan On Time is programmed in the 1-600 second range. Figure 33 illustrates the fan operation due to this input. The A/C Pressure Switch Fan-On Time is programmable from 0 to 600 seconds. If the Parameter is at 0 seconds, the ECM will not respond to the input. Figure 33 - “A/C High Pressure Switch Operation” indicates the ECM A/C High Pressure Switch operation.