1 minute read

OPERATING INSTRUCTIONS RH 340 Electric OPeration

Fire extinguisher

The excavator is equipped with two four extinguishers. The conventional one is located near the drivers cab (Fig. 2-39:), the carbon dioxide fire extinguishers are located near the electric motor and switching cabinets.

Handling

The excavator driver and the maintenance personnel must informthemselves about how to handle the fire-extinguisher in order to be able to act fast and efficiently in case of beginning fires. Such instruction should be given by a qualified instructor.

Extinguishing agent

The conventional fire-extinguisher is filled with 12 kg (26.4lb) Glutex. This extinguishing agent is used for fighting fires of classes A, B and C. Fires are extinguished fast, perfectly and without residues.

The carbon dioxide fire extinguishers are intended for fighting fires of electrical parts.

 Pull out securing pin (2, Fig. 2-40:).

 Strike knob (3) hard, then release again.

 Operate the extinguishing gun.

After fire-fighting, the extinguisher must be refilled Immediately and prepared ready for use.

Inspection

Have the extinguisher inspected at regular intervals by an expert. This is required by local authorities and insurance companies and is in the interest of your own safety.

Have the fire-extinguisher checked at the prescribed intervals by authorized testing agencies.

This article is from: