Inspection and servicing
Other Maintenance
Heating and air conditioning
Change the filter mats in the air suction regulary. The filter mats are located under the driver`seat.
Before starting servicing works on the air conditioner system close ball valves (1, Fig. 3-107:) in the feeding- and the return pipeline to the air conditioner unit (levers are in transvers direction)
The ball valves (1) are accessible from the bottom.
" Remove cover (1, Fig. 3-106:)-
" Change filter mats (2)
" Fasten cover (1) again.
Open ball valves (1, Fig. 3-108:) after finishing service works on the air conditioner system (levers are in longitudinal direction)