18th Edition Multifunction & other associated Test Equipment including EV-Test100 PAT Testers & associated Accessories Safe Isolation Test Equipment & associated Accessories including Voltage Testers and Proving Units
Product Catalogue
Thermal Image & Boroscope Equipment Digital Multimeters & Accessories Digital Clamp Meters & Accessories Phase, Fuse Socket & Specialised Test Equipment Voltage Detectors Environmental Test Equipment Various Test Leads & Carrying Cases Electrical Certificate Forms & Electrical Warning Labels Solar Photovoltaic Test Equipment Power Quality Analysers Earth Resistance Test Equipment Data Loggers Single & 3 Phase Version V010
Power Harmonic Clamp Meters Network Cable Wire Mappers
Click any of the above links to follow TIS on Social Media
Web: www.testinstrumentsolutions.co.uk
Calibration Service In House or On Site for Test Equipment of most manufacturers
Product Index
Non Contact Voltage Detectors
Multifunction Test Equipment MFT-PRO MFT-ECO TIS EV-TEST100 TIS Checkbox TIS 1835 TIS Checkbox HT7051 HT7052 Accessories
Professional TRMS Multifunction Installation Tester Multifunction Installation Tester with 2 Wire Loop Test EV Testing Adapter / Complete EV Testing Kit Calibration Checkbox Digital Insulation and Continuity Tester Calibration Checkbox Professional Insulation Meter Professional Insulation Meter Range of Multifunction Test Equipment Accessories
4 6 7 6 8 8 76 77 9
PAT Testing Equipment TIS 700 TIS 600 Accessories
SafetyPat Elite Downloading Portable Appliance Tester SafetyPat Plus Portable Appliance Tester Range of PAT Testing Accessories
11 11 12
Safe Isolation Equipment TIS 859 SIKIT TIS 849 SIKIT TIS 851 SIKIT TIS 819 SIKIT TIS 859 PKIT TIS 849 PKIT TIS 851 PKIT TIS 819 PKIT TIS 851 TIS 819 TIS PU1 TIS 849, 859 TIS 829 TIS BKIT, TISEKIT Accessories
Voltage & Continuity Safe Isolation Kit Voltage & Continuity Safe Isolation Kit Voltage & Continuity Safe Isolation Kit Voltage & Continuity Safe Isolation Kit Voltage, Continuity & Proving Kit Voltage, Continuity & Proving Kit Voltage, Continuity & Proving Kit Voltage, Continuity & Proving Kit LCD and LED Voltage and Continuity Tester Voltage Tester Proving Unit Range of Voltage and Continuity Testers Replacement Lead Set Safety Lockout Kits Safe Isolation Accessories
14 14 15 15 16 16 16 16 17 17 17 18 18 20 20
Digital Thermal Imaging Equipment TIS 1900 THT70, THT60 THT46 THT33 HTB500 BP36
Digital Thermal Image Camera Advanced Infrared Thermal Cameras Compact Infrared Thermal Camera Infrared Thermal Camera Boroscope with Rechargeable Battery 3 meter IP67 probe
21 70 71 72 73 73
Digital Multimeter Test Equipment TIS 258 TIS 201 TIS 280 TIS E217 TIS E227
Digital Multimeter with Temperature Pocket Size Digital Multimeter with Temperature Auto-Ranging Digital Multimeter Elite Range Electrical Multimeter Elite Range Professional Multimeter
23 23 23 24 24
Auto-Ranging Clamp Meter Auto-Ranging Clamp Meter TRMS Auto-Ranging Clamp Meter with Inrush Reading Elite Range Digital Clamp Meter with Amp™Tip Jaws Elite Range Digital Clamp Meter with Amp™Tip Jaws Elite Range Digital Clamp Meter with Amp™Tip Jaws Earth Leakage Clamp Meter AC Line Splitter Clamp Meter with Flexible Jaws
27 27 27 28 28 28 30 30 75
Phase, Fuse, Socket & Specialised Test Equipment TIS 415 TIS 870 TIS 1000 TIS 1005 TIS USB1 TIS 888 TIS 1040 TIS LD80 TIS 880 TIS 1100
2
Phase Rotation / Motor Rotation Tester Circuit Fuse / Breaker Finder Socket Tester with Sounder Socket Polarity Checker with Loop and RCD USB Tester Multifunction Tone Generator & Cable Tracker Lamp and Control Gear Tester Laser Distance Meter Network Cable Tester R2, R1 + R2 Socket Adapter
01274 752 407
Optical / Accoustical Non-Contact Voltage Detector Optical / Accoustical Non-Contact Voltage Detector Non-Contact Voltage Detector with IP65 Rubber Housing
36 36 36
Environmental Test Equipment TIS 1309 TIS 1310 TIS 770 TIS 82 TIS 720 Probes TIS BODYIR
Digital Anemometer Digital LED Light Meter Digital Sound Level Meter Non-ContactInfrared Thermometer Dual Input K-Type Digital Thermometer Range of K-Type Probes Dual Forehead & Ear Medical Infrared Thermometer
38 38 39 39 40 40 41
Various Test Leads & Carrying Cases TIS JUMPTL TIS 172ML TIS 173DB TIS 50 TIS 2FLK TIS 3TLK TIS 4TL TIS 25 TIS PUK TIS 15
Jump Leads with Crocodile Clips Universal Mains Lead Distribution Board Lead Set with Probes & Crocodile Clips 50M Earth Wander Reel Fused Test Lead Set Fused Test Kit (unfused) Test Leads Large Test Instrument Pouch Dual Instrument Pouch Small Test Instrument Pouch
43 43 43 43 44 44 44 45 45 45
Various Certificate Pads, Books & Electrical Safety Labels TIS 1901 - 1710 TIS 1814 - 1817 TIS 1908 Labels
Electrical Installation and Inspection Certificate Pads Fire Alarm and Emergency Lighting Books EVSE Test Report Various Testing Labels and Electrical Safety Labels
46 46 46 47
Solar Photovoltaic Equipment PV-ISOTEST I-V500w I-V400w PVCHECKs
Multifunction Photovoltaic System Tester I-V Curve Measurement Photovoltaic Tester I-V Curve Measurement Photovoltaic Tester Multifunction Photovoltaic System Tester
49 50 52 54
Power Quality Analysers PQA824 PQA823 VEGA78 PQA820
Three-Phase Power Quality Analyser Three-Phase Power Quality Analyser Three-Phase Power Quality Analyser Three-Phase and Single-Phase Power Quality Analysers
57 57 57 59
Earth Resistance Test Equipment T2000 T2100
Earth Resistance Clamp Meter Earth Resistance Clamp Meter
61 61
Single & 3 Phase Data Loggers
Digital Clampmeter Test Equipment TIS 518 TIS 418 TIS 438 TIS E237 TIS E247 TIS E257 TIS 560 TIS 455 F3000
TIS 958 TIS 934 TIS 950
01274 870 175
32 32 32 33 33 33 34 34 35 35
XL421 XL422 XL423 XL424
TRMS Single-Phase Current Data Logger TRMS Three-Phase Current Data Logger TRMS Single-Phase Voltage Data Logger TRMS Three-Phase Voltage Data Logger
63 64 65 66
Power Harmonic Clamp Meters HT9023 HT9020
Professional Clamp Meter with Power Harmonics Professional Clamp Meter with Power Harmonics
68 69
Network Cable Wire Mappers QUICKLAN6050 Wire Mapper for Cable Tests QUICKLAN6055 Wire Mapper for Cable Tests
74 74
Calibration Service Full Details of our Service and Instruments that we can Calibrate Pages 78 - 79
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Multifunction Test Equipment MFT-PRO
Page 4
MFT-ECO
Page 6
EV-TEST100
Page 7
MFT-PRO / EV-TEST100 Set
Page 7
TIS 1835
Page 8
TIS Checkbox
Page 8
HT7051 & HT7052
Pages 76/77
Multifunction Accessories
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1901
Domestic & Similar Premises Electrical Installation Certificate Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
For Certification of:
New Installation Rewire Addition of one or more new circuits to existing installation Replacement of consumer unit
18th E D I T I O N
TIS 172ML
Page 9
TIS 173DB
Page 9
TIS 50
Page 9
TIS 1901
Page 9
TIS 1903
Page 9
TIS 1905
Page 9
TIS 1906
Page 9
TIS 1908
Page 9
TIS JUMPTL
Page 9
TIS LIGHTAD
Page 9
Printing errors and omissions excepted
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1903
Domestic & Similar Premises Electrical Condition Report Up to 100A Requirements for Electrical Installations BS 7671: 2018
For completion reporting on the condition of an existing electrical installation
18th E D I T I O N
Printing errors and omissions excepted
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1905
Schedule of Test & Circuit Details Continuation Sheets Requirements for Electrical Installations BS 7671: 2018
For completion reporting on the condition of an electrical installation
18th E D I T I O N
Printing errors and omissions excepted
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1906 Minor Works Electrical Installation Certificate Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
To be used for minor electrical work only, which does not include the provision of a new circuit
18th E D I T I O N
Printing errors and omissions excepted
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
3
MFT-PRO
Professional TRMS Multifunction Installation Tester with EVSE Testing Capabilities SPECIAL FUNCTIONS
NEW EVSE Testing Capabilities, Full Auto-Sequence using TIS EV-TEST100
NEW 6mA DC RCD & Ramp Test for EVSE Charging Points
NEW Auto Sequence performs Loop, RCD & both cycles of the Ramp Test from pressing the test button once.
TFT Large Colour LCD Display, 320 x 240 pixels
Phase to Phase Loop Testing
TRMS for accurate measurements on noisy and distorted circuits
Resistive Touch Screen, works even with gloves on!
Full Help Schematic Display
Built in Fuse Characteristic Table, OK and Fail Display
Measurement of Continuity > 200mA
Supplied withsystems Neck Strap & Harness for Hands Free Use COMBIG2 is used for checking the safety of domestic and industrial electric (IEC/EN61557-1). Displays both L-N, L-PE with PFC & PSC Simultaneously on No TripasTest Thanks to its building characteristics, the type of setting and the multiple applications with BSEN regards the documentation it is capable of producing, this device can satisfy even the61557-1-2-3-4-5-6-7 most Compliant 17th Amendment 3 & 18th Edition demanding technician and the most rigorous verifier. Accurate PRO-LOCK No Trip Its TFT colour display with touch-screen allows using this device in a completely newLoop Test Phase SequencetoMeasurement manner. COMBIG2 makes available on its display all possible variables obtain a Selection of RCD type and tripping current perfect measurement; your task will only be to “touch” what reallyand wantReliable, to measure: you Accurate ‘No Trip’ Loop Testing then, simply leave the rest to COMBIG2’s micro-processor! For Video Demonstration Line / Loop Impedance, Phase - Phase Phaseof - Neutral, - PE The device complies with all requirements as regards the safety electricPhase systems: test of RCDs type A, AC also up to 1000 mA and type B;insulation, earth Insulationcontinuity, Test at 50, 100, 250, 500 and 1000V resistance tests directly on the power outlet without causing RCDs’ tripping. the RCD Testing up to 1A, or 10A with optional adapter GENERAL CHARACTERISTICS With the appropriate programming guided by the touch-screen system, this device test x 1 x 5 x ½, Contact Voltage Automatic RCD Test,can 0o 180o, Power 6 x 1.5V AA alkaline batteries theSupply: breaking capacity, tripping current, I2t relevant to magneto-thermal switches Ramp Test in one visit Battery Life: > 550 test (alkaline) (MCB) with curves B, C, D, K and fuses type gG and aM! Display: Resistive touch screen, colour LCD resolution 320x240 pxl Tripping time of General, Selective out and record measureCombined with optional clamp HT96U it is capable to carry 3negative YEAR * Memory: 999 locations, 3 levels of markers and Delayed RCDs A, AC and B Measurement result WARRANT Y ments ofoptical/USB leakage and current, PC Interface: WiFi power, cosphi, harmonics, THD% and frequency. This deMeasurement of Voltage, Current, Active Safety: double viceIEC/EN61010-1, has been devised forinsulation use together with optional accessories which widen its operating Reactive, Apparent Power Operating <80%RHfor measuring lux, HT52/05 for measuring temperature and humidity fields:Humidity: e.g. HT53/05 Fully Compliant Measurement of Cosphi, Power Factor Operating Temperature: 0 ÷ 40°C and RCDX10 for testing earth leakage relays up to 10A. BS EN 61557 Storage Humidity: <80%RH Optional adapters for measuring PQA, at the Cutting-edge management of measurement with indication, end of each safety test, Storage Temperature: -10 ÷ 60°C Earth Leakage, Lux & Temperature Fully Compliant of compliance or non-compliance with requirements symbols OK o NOT OK. Measurement Category: CAT IV 300V, Max 415V between inputswith simple IET 18th Edition Memory 999 Locations, 3 Level Markers Pollution Level: 2 to the brand new HTAnalysis App, free to download for iOS and Android Finally, thanks interface integrated WiFi communication Reference Standard: IEC/EN61557-1-2-3-4-5-6-7 systems, COMBIG2 is capable of transferring measured and PC recorded data onto tablets CAT III and CATIV Size (LxWxH): 225 x 165 x 75 mm Softwareand Included and smartphones, thus giving the operator the possibility to customize share through Selection of measurement type of Weight (inc. batteries):1.2 kg phase sequence HtCloud the result of their tests. Accessories (Supplied): Neck Strap with Harness
HT ANALYSIS APP
CARRIES OUT
4
01274 752 407
C2033X
01274 870 175
Cable with 3-terminal Shuko plug
Selection with exter
Measureme with option
(Important Extracts from BS7671 : 2018, IET 18th Edition)
Harmonic Current Measurements
Power Factor Measurements in line with chapter 33, 331.1 page 51 BS7671 : 2018 (IET 18th Edition)
Voltage Drop Measurements
Power Factor V, A, Hz, kW, kVAr, kVa, COS as recommendation in Appendix 17
and PF
*Energy Efficiency, Page 513 BS7671 :General 2018 (IET 18th Edition) screen Thanks to the brand new HT Analysis App which is free to Advanced Loop Power measurement, using the HTAnalysis™ App on tablet. *It is intended that Appendix 17 will be developed into Lux measurement with accessory download for IOS and Android systems, the unit is capable of HT53/05. Part 8 of BS7671 in a future amendment transferring measured and recorded data onto smart phones or tablets. This provides the operator the possibility to customise and share through HT Cloud the results and information of the * Provided the instrument is calibrated by TIS/TIC in year 2 and 3. tests, producing a complete solution to your testing needs.
Accessories provided
Selection minimum urement
Negative re capacity tes
Optional accessories
This also includes free software updates.
sales@tis-tic.co.uk Please contact your local wholesaler for pricing HT96U
AC clamp for leakage current, 1-100
Professional TRMS Multifunction Installation Tester with Power Quality Analysis & Wifi AT last, a true ‘All in One’ Tester for the professional electrician with phase to phase loop testing, a large TFT colour LCD display, Trms for accurate measurements on noisy and distorted circuits. Auto mode allows loop PE, PN, PSC, PFC, RCD 00, 1800 x ½ x 1 x5 and both cycles of the ramp test from one connection and one press of the text button, accurate prolock, no-trip testing. Accurate and easy to use nulling of all your test leads, power quality analysis, harmonics to the 25th, full help schematic colour display, resistive touch screen works even with gloves on. Fully compliant with BS EN 61557, BS 7671 17th and 18th Editions of the IET Regulations, plus much more!
AUTO AUTO TN-50V TN-50V
AUTO AUTO TN-50V TN-50V
20-05-2018 20-05-2018 14:32 14:32
00 VV Complete set of test results having
conducted a Power Quality Analysis 10mA 10mA LL
00 VV
00 VV
IIPSC PSC
-- -- --
IIPFC PFC
-- -- --
Min Min
30mA 30mA
20-05-2018 20-05-2018 14:32 14:32 20-05-201 AUTO AUTO TN-50V TN-50V Results from Earth Leakage Test carried out using the optional 20-05-201
clamp adapter as featured on the back cover of this brochure
A A ZZL-N L-N
-- -- --
IIPSC PSC
1437 1437 A A
ZZL-N L-N
0.16 0.16
IIPFC PFC
1277 1277 A A
ZZL-PE L-PE
0.18 0.18
0.0 0.0
V V
Min Min
A A ZZL-PE -- -- -L-PE
Min Min
-- -- -- V V 30mA 30mA
Outcome of No Trip Loop Test displaying Z L-N, Z L-PE Results and IPSC & IPFC results AUTO AUTO TN-50V TN-50V
0° 0° mA 22.5 22.5 mA X X1 1
ms ms
38 38
20-05-2018 20-05-2018 14:32 14:32
180° 180° mA 24.0 24.0 mA 35 35
ms ms
X X5 5
22 22
ms ms
27 27
ms ms
X½ X½
>999 >999
ms ms
>999 >999
ms ms
30mA 30mA
Temperature measurement taken using the optional temperature adapter AUTO AUTO TN-50V TN-50V
AU AU
20-05-2018 20-05-2018 14:32 14:32
IIPSC PSC
1437 1437 A A
ZZL-N L-N
0.16 0.16
IIPSC PSC
IIPFC PFC
1277 1277 A A
ZZL-PE L-PE
0.18 0.18
IIPFC PFC
Min Min
Min Min
-- -- --
Min Min
Min Min
V V
30m 30m
30mA 30mA
30mA 30mA
Outcome of Auto RCD Test showing x1, x5, x½, 0o and 180o
Allows you to perform No Trip Loop Test, Ramp Test, Auto RCD Test (30mA) and both cycles of Ramp Test. From pressing the test button once. Results shown are from the No Trip Loop Test which show L-N, L-PE, PSC and PFC
TIS EV-TEST100 (optional extra)
PR400
01274 752 407
HT96U
(optional extra)
01274 870 175
Outcome of EVSE Pod Set up screen
R R
30mA 30mA
30mA 30mA
Min Min
(optional extra)
N N
6mA 6mA
Outcome of Continuity Test with actual result and current injected N N PE PE
AUTO AUTO TN-50V TN-50V Outcome of an Insulation Test showing passed result
NECK STRAP WITH HARNESS (SUPPLIED)
20-06 20-06
Outcome of EVSE Continuity Auto Sequence Set up screen
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
5
Multifunction Installation Tester with accurate & reliable 2 Wire Loop Test SPECIAL FUNCTIONS
For Video Demonstration
2* and 3 Wire Loop Test (*European patent pending)
Automatic Testing of 3 Insulation Tests from one connection
TRMS for accurate measurements on noisy and distorted circuits
LPE/LN with PFC/PSC results displayed on single test
New Auto Start Mode, On or Off for easy testing
Dual Test Button for Left or Right hand use
Neck Strap and Safety Harness
Built in Fuse Characteristic Table, OK and Fail Display
Accurate and Reliable ‘No Trip’ Testing, Line / Loop Impedance Phase - Phase, Phase - Neutral, Phase - PE with 2 Wire Mode
Phase to Phase Loop Test
Full Help Schematic Display
Large COG Graphic LCD Display 128 x 128 pixels
Compliant with BSEN 61557-1-2-3-4-5-6-7, 18th Edition
RCD Testing 6mA to 1A
Fast Automatic RCD Test, 00 1800 x 1 x 5 x ½ with Ramp & Contact Voltage Tests
Auto Mode Loop and RCD Tests in a single test
Tripping of General, Selective RCDs A, AC
Continuity Test of Earth Conductors with Test Current >200mA
Phase Sequence Measurement
Insulation Test at 50, 100, 250, 500 and 1000V DC
Safety Compliance with IEC EN 61010-1
Built in Pass / Fail Levels
Measurement Category CAT IV 300V
SUPPLIED WITH
Neck Strap and Safety Harness
PR400 Remote Switch
Test Leads, Probes and Crocodile Clips
6 x Alkaline Batteries
Soft Padded Carrying Case
12 Month Calibration Certificate
Guarantee upgradeable to 3 years
3 YEAR *
WARRANT Y
* Provided the instrument is calibrated by TIS/TIC in year 2 and 3. This also includes free software updates.
6
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS EV-TEST100
EV Testing Adapter
For Fully Automated Results please use in conjunction with the MFT-PRO MAIN FEATURES
Charging Modes
MFT-PRO - EV
Tests Mode 2 and Mode 3 Charging Stations
Tests Type A-30mA, B-6mA and B-30mA RCDs
CAT III 300V Measurement Category
Fault Simulation ( PE and E )
Phase Presence Indication
Type 2 Connection
IP40 Protection
Data Saving using the TIS MFT-PRO
Data Export using the Top View Software
External Load - Fused Max 10A/230V
Vehicle Status Simulation (CP) A,B,C,D
Guided AUTO Test Sequence using the TIS MFT PRO
Cable Coding Simulation (PP) Open, 13A, 20A, 32A and 63A
Standards, IEC/EN61010-1, IEC/EN61851-1 and IEC/EN60364-7-722
The TIS EV-TEST100 can be used with Most Multi Function Testers
2 YEAR *
WARRANT Y
EVSE Test Report also available (page 9)
Complete EV Testing Kit For Video Demonstration
Please see individual functions of the MFT-PRO on page 4
EVSE Test Report also available (page 9)
Both Products can be purchased separately
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
7
TIS 1835
Handheld TRMS Insulation Resistance Tester with Multimeter Features
The TIS 1835 Digital Insulation Tester meets all the requirements of the 18th Edition and is packed full of features which are listed below and includes all the features of a digital multimeter and a high end digital insulation tester, with 0.01 of an ohm at 200mA.
SPECIAL FUNCTIONS
Insulation Range 50, 100, 250, 500 & 1000 Volt, (Stepping 10%) 99 - Group Data Storage Measuring Range 50MΩ up to 20.0GΩ With 0.01 of an ohm at 200mA High Voltage Output Alarm Continuity R1 R2 Testing 20.00KΩ, >200mA with Buzzer EN: 61010-1 2 YEAR TRMS CAT III 1000V WARRANT Y AC Voltage Range 0 - 600V, 0.1V ± 2% + 3 DC Voltage Range 0 - 600V, 0.1V ± 2% + 3 DAR + P1 / Timing Measurment Frequency DC 50Hz - 400Hz Step Voltage Compliance Standards EN61557-1-2007, EN61557-2-2007, EN61557-4-2007 Compliance Standards EN61326-1-2013, EN61326-2-2-2013, EN61010-2-030-2010 Compliance Standards EN61010-2-033-2012 and IET 18th Edition Display with Max Reading being 9999 Data Hold Low Battery Alarm Analogue Bar Graph CAT IV 600V Battery Life Expected on new set of Alkaline Batteries 800 Insulation Tests Uses 6 x AA, 1.5V Batteries Automatic Discharge of Voltage Back Lit Display Lock Timer Feature Complete with Test Leads, Aligator Clip, Batteries & Padded Case
TIS CHECKBOX
Calibration Checkbox
The TIS Checkbox is a very useful tester which ensures on a weekly, monthly basis that all your multifunction testers or individual loop, RCD, insulation and continuity testers are within specification. This unit does not replace your annual calibration procedures.
EN: 61010-1 CAT IV 600V
EMC & LVD EN: 61010-1
COMPLETE WITH Calibration Certificate COMPLIANT WITH BSEN 61326
CALIBRATION CHECKS ON All types and makes of Multifunction Tester All types and makes of separate Loop, RCD & Insulation / Continuity Tester 2 YEAR WARRANT Y Checks Continuity 0 - 10Ω Checks Insulation Resistance 1 - 200Ω RCD Test checks at 30mA and 150mA Checks Loop at socket +0.50Ω, +2.00Ω and 50Ω Can be used to check Voltage & Resistance on Multimeters Easy to Use Compact Design Complete with Padded Case
8
01274 752 407
01274 870 175
“Please note a Checkbox does not replace your annual Calibration Certificate”
For Video Demonstration
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 172ML
Universal Mains Lead
The TIS 172ML is a universal mains lead that can be used with most multifunction testers and our own MFT-PRO & MFT-ECO.
TIS 173DB
Distribution Board Lead Set with Probes and Crocodile Clips
The TIS 173DB is a rugged constructed distribution board lead set, constructed with silicone cable, making it extremely flexible, the set comes complete with probes and rugged strong crocodile clips and is fitted with standard 4mm terminals making it suitable for our own MFT-PRO & MFT-ECO, plus most other test instrumentation, no matter what manufacturer.
TIS 50
50M Earth Wander Reel
The 50m earth wander reel is to enable performance of r2 testing and is easy to use, on a quick and simple rewindable reel it has a 4mm terminal to fit the majority of test equipment no matter what manufacturer.
TIS LIGHTAD
Lamp Adapters
The TIS LIGHTAD Lamp Adapters are ideal for all types of lamp holder connectors, enabling simple and easy testing of all lighting circuits.
TIS JUMPTL
Jump Leads with Crocodile Clips
Ideal for use when carrying out insulation testing or continuity testing at a distribution board. Length of leads: 2 x 170mm & 2 x 450mm.
TIS 1901 - 1710
Range of Electrical Installation and Inspection Certificates & TIS 1908 EVSE Test Report
TIS 1901
Domestic & Industrial Electrical Installation Certificate Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1901
Domestic & Similar Premises Electrical Installation Certificate Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
For Certification of: New Installation Rewire Addition of one or more new circuits to existing installation Replacement of consumer unit
TIS 1903
Domestic & Industrial Electrical Condition Report Up to 100A Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
18th E D 18th I TIS 1903 E T Domestic & Similar Premises Electrical Condition Report D Up I to 100A I O TIS 1905 T Schedule of Test N & Circuit Details Continuation Sheets I O N Tel: 01274 752 407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
Tel: 01274 752 407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
Requirements for Electrical Installations BS 7671: 2018
For completion reporting on the condition of an existing electrical installation
Printing errors and omissions excepted
Requirements for Electrical Installations BS 7671: 2018
For completion reporting on the condition of an electrical installation
TIS 1905
TIS 1906
E D I TIS 1906 T Minor Works Electrical Installation Certificate I O N
Tel: 01274 752 407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
Printing errors and omissions excepted
Schedule of Test & Circuit Details Continuation Sheets Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
18th
To be used for minor electrical work only, which does not include the provision of a new circuit
Printing errors and omissions excepted
18th E D I T I O N
Printing errors and omissions excepted
Minor Works Electrical Installation Certificate Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
TIS 1908
EVSE Test Report
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
9
PAT Testing Equipment TIS 700
Page 11
TIS 600
Page 11
PAT Testing Accessories TIS 110
Page 12
TIS IEC
Page 12
TIS 164
Page 12
TIS 165
Page 12
TIS 324
Page 12
TIS 325
Page 12
TIS 455
Page 12
TIS 1710
Page 12
Various PAT Test Labels
Page 12
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1710 Portable Appliance Inspection and Test Records
Printing errors and omissions excepted
Re-Test Due:
FAILED
Test Date:
ID:
Amp
Test Engineer:
DO NOT USE
01274 752 407
ELECTRICAL SAFETY TEST
10
FUSE
Test Engineer:Appliance
RATING
PASSED
Test Date:
ELECTRICAL SAFETY TEST
Appliance ID:
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 700
SafetyPat Elite Downloading Portable Appliance Tester
The TIS 700 Safety Pat Elite is a unique downloading pat tester being the first pat tester with built in and removeable SD card, which can store up to 1 million test results. Then you simply remove the SD card and put it into your PC, the SD card will download all its information into Excel, producing smart pass and fail certification with client details, etc. All this without the need for an expensive software package!
For Video Demonstration
SPECIAL FUNCTIONS
Full QWERTY Keypad Stores up to 1 million Results onto SD Card Appliance Description Entry Next Due Test Date Stores minimum of 3000 Test Results SD Card formatted as Excel File Automatically creates Test Result Certificates SD Card ensures your tester is always testing Mains Adapter User Name Entry Client Name Entry Location Entry Battery Operated Plus All the normal Testing Features
TIS 600
2 YEAR
WARRANT Y
BASIC FUNCTIONS
RANGE
Earth Continuity up to 0.5Ω Insulation Test 250V / 500V True Reading of Leakage 110V & 230V Polarity Test Surge Protected Equipment
SafetyPat Plus Portable Appliance Tester
The TIS 600 Safety Pat Plus is a very simple and easy to use portable appliance tester that works from batteries or an AC/DC power adapter, it will also test ALL portable equipment, 110V, 230V or 415V (110V and 415V with optional adapters). Built in memory stores 300 results which can be written down later, it’s as simple as A, B, C, press the button and the tester does the rest. Complete with a padded carrying case, batteries and AC/DC adapter.
SPECIAL FUNCTIONS
Tests 230V, 110V & 415V Appliances Battery & Mains operation Simple and very easy to use Fully Portable Automatically Stores Test Results Tests long Extension Leads Tests I.T. Equipment, Computers, etc 250V & 500V Insulation Test Stores up to 300 Test Results 110V and 230V True Leakage Results Tests up to 0.5Ω Indicates if appliance is on or off Complete with free 12 month calibration certificate Will even test equipment that does not conform to EN60950 Single press of the button from start to finish Large LCD Display Rugged Case with Rubber Boot Carry Strap and Harness
01274 752 407
01274 870 175
2 YEAR
WARRANT Y
BASIC FUNCTIONS
RANGE
Earth Continuity up to 0.5Ω Insulation Test 250V / 500V True Reading of Leakage 110V & 230V Polarity Test Surge Protected Equipment
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
11
TIS 110
230V to 110V Adapter
This Adapter allows you to test all your 110V equipment using the 230V output socket on your PAT Tester.
TIS IEC
110V to IEC Adapter
This Adapter allows you to test all your 110V extension leads by connecting into the end of the uncoiled cable and placing the IEC end into the appropriate socket at the rear of your PAT Tester.
TIS 164
16A 415V 4pin Adapter
This Adapter allows you to test all your 415V equipment using the 230V output socket on your PAT Tester.
TIS 165
16A 415V 5pin Adapter
This Adapter allows you to test all your 415V equipment using the 230V output socket on your PAT Tester.
TIS 324
32A 415V 4pin Adapter
This Adapter allows you to test all your 415V equipment using the 230V output socket on your PAT Tester.
TIS 325
32A 415V 5pin Adapter
This Adapter allows you to test all your 415V equipment using the 230V output socket on your PAT Tester.
TIS 455
For further details please see Page 30
AC Line Splitter with Earth Leakage Measurement
The TIS 455 Line Splitter is an ideal accessory when using a clamp meter to measure AC current as it splits the live conductor from the neutral and earth. Ideal when PAT testing to measure loads of individual equipment, including Earth Leakage
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1710
TIS 1710
Certificate Book
Portable Appliance Inspection and Test Records
Portable Appliance Inspection and Test Records. In compliance with IET Code of Practice 4th Edition.
01274 752 407
01274 870 175
49mm x 25mm - Pack of 200
FAILED
Amp
TIS 1613-200 Standard Failed Labels
Appliance ID: Test Date:
Test Engineer:
DO NOT USE
ELECTRICAL SAFETY TEST
12
Test Engineer:
Re-Test Due: RATING
49mm x 25mm - Pack of 500
Test Date:
FUSE
Standard Passed Labels
Appliance ID:
ELECTRICAL SAFETY TEST
TIS 1612-500
PASSED
Printing errors and omissions excepted
Full Range of PAT Test Labels on Page 47
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Safe Isolation Equipment TIS 859 & 849 SIKITs
Page 14
TIS 819 & 851 SIKITs
Page 15
TIS 849, 859, 851, 819 PKITs
Page 16
TIS 851
Page 17
TIS 819
Page 17
TIS PU1
Page 17
TIS 849
Pages 18/19
TIS 859
Pages 18/19
Safe Isolation Accessories
01274 752 407
TIS 829
Page 18
TIS BKIT
Page 20
TIS EKIT
Page 20
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
13
TIS 859 SIKIT
Voltage & Continuity Complete Safe Isolation Kit
Kit Contains: TIS 859 1000V AC/DC Digital Voltage & Continuity Tester (full details on page 18/19)
TIS PU1 Proving Unit (full details on page 17)
TIS PUK Dual Instrument Pouch (full details on page 45)
TIS BKIT Lockout Kit inc. Hasp, Padlocks, Tag, etc (full details on page 20)
A TRUE Complete Safe Isolation Kit
TIS 849 SIKIT
Voltage & Continuity Complete Safe Isolation Kit
Kit Contains: TIS 849 1000V AC/DC Digital LCD LED Voltage & Continuity Tester (full details on page 18/19)
TIS PU1 Proving Unit (full details on page 17)
TIS PUK Dual Instrument Pouch (full details on page 45)
TIS BKIT Lockout Kit inc. Hasp, Padlocks, Tag, etc (full details on page 20)
A TRUE Complete Safe Isolation Kit
For further information please see the below pages: TIS 859 & 849 pages 18 & 19, TIS PU1 page 17, TIS PUK page 45, TIS BKIT page 20
14
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 851 SIKIT
Voltage & Continuity Complete Safe Isolation Kit
Kit Contains: TIS 851 Voltage & Continuity Tester (full details on page 17)
TIS PU1 Proving Unit (full details on page 17)
TIS PUK Dual Instrument Pouch (full details on page 45)
TIS BKIT Lockout Kit inc. Hasp, Padlocks, Tag, etc (full details on page 20)
A TRUE Complete Safe Isolation Kit
TIS 819 SIKIT
Voltage Only Complete Safe Isolation Kit
Kit Contains: TIS 819 Voltage Tester 12V 690V AC/DC (full details on page 17)
TIS PU1 Proving Unit (full details on page 17)
TIS PUK Dual Instrument Pouch (full details on page 45)
TIS BKIT Lockout Kit inc. Hasp, Padlocks, Tag, etc (full details on page 20)
A TRUE Complete Safe Isolation Kit
For Video Demonstration
For further information please see the below pages: TIS 851 page 17, TIS 819 page 17, TIS PU1 page 17, TIS PUK page 45, TIS BKIT page 20
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
15
TIS 859 PKIT
Voltage, Continuity & Proving Kit
KIT CONTAINS
TIS 859 - please see page 18/19 for a full list of features
1000V AC/DC Digital Voltage & Continuity Tester, with Built In Resistance, Capacitance, 3-Phase Rotation Detection 30mA RCD Test, Contact / Non Contact Voltage
2 YEAR
WARRANT Y
COMPLIANT WITH
TIS PU1 - please see page 17 for a full list of features
BSEN 61243-3: 2014
Proving Unit
COMPLIANT WITH H. S. E. GS38
TIS PUK - please see page 45 Dual Instrument Pouch
TIS 849 PKIT
Voltage, Continuity & Proving Kit
KIT CONTAINS
2 YEAR
TIS 849 - please see page 18/19 for a full list of features
1000V AC/DC Digital LCD LED, Audible & Shaker Voltage & Continuity Tester, with Built In Voltage Detector, 30mA RCD Test & 3-Phase Rotation Detection
COMPLIANT WITH BSEN 61243-3: 2014
TIS PU1 - please see page 17 for a full list of features Proving Unit
WARRANT Y
COMPLIANT WITH H. S. E. GS38
TIS PUK - please see page 45 Dual Instrument Pouch
TIS 851 PKIT
Voltage, Continuity & Proving Kit
KIT CONTAINS
2 YEAR
TIS 851 - please see page 17 for a full list of features
WARRANT Y
TIS PU1 - please see page 17 for a full list of features
BSEN 61243-3: 2014
Voltage & Continuity Tester, with Built In Non-Contact / Contact Voltage Detector
COMPLIANT WITH
Proving Unit
COMPLIANT WITH H. S. E. GS38
TIS PUK - please see page 45 Dual Instrument Pouch
TIS 819 PKIT
Voltage Tester and Proving Kit
2 YEAR
KIT CONTAINS
TIS 819 - please see page 17 for a full list of features Voltage Tester 12V 690V AC/DC
TIS PU1 - please see page 17 for a full list of features Proving Unit
WARRANT Y
COMPLIANT WITH BSEN 61243-3: 2014
COMPLIANT WITH H. S. E. GS38
TIS PUK - please see page 45 Dual Instrument Pouch
16
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 851
LCD and LED Voltage / Continuity Tester with Phase Rotation & Built In Proving Test
The TIS 851 is an exclusive voltage and continuity tester, with phase rotation test and a built in proving test that conforms fully to BSEN 61243-3: 2014 and HSE GS38 12B. The TIS 851 is packed with many outstanding features which include will not trip any rcd when testing between live and earth, digital LCD and LED voltage indication, indicates the presence of voltage even if the battery is dead or missing, built in two pole phase rotation test, AC / DC voltage 0 - 690V, single pole phase test, all this plus much more. Please see the full list of outstanding features in the section below marked ‘special functions’.
BASIC FUNCTIONS RANGE
ACCURACY
AC/DC Voltage
12V/24V/50V/120V/230V/400V/690V
Continuity Test Phase Rotation Test Phase Range Response Time Peak Current Internal Battery Consumption
0 - 1MΩ 3 Phase 4-wire system AC 50/60Hz 120±5 degree <2s at 90% of each Voltage <3.5mA (at 690V) Approx. 33mA (Battery 3V, measuring 690V AC)
±(3%+3d) or 5V
2 YEAR
WARRANT Y
Compliant To
EN: 61010-1
BSEN 61243-3 : 2014
GENERAL CHARACTERISTICS Power: 1.5V x 2 AAA Batteries Weight: 180g Size: 245mm x 70mm x 30mm Accessories: Padded Case
EN: 61010-1
EN: 61010-1
GS38
CAT III 1000V
CAT IV 600V
COMPLIANT
SPECIAL FUNCTIONS
AC/DC Voltage 0V - 690V, LED 12V - 690V Cat III 1000V, CAT IV 600V Will Not Trip RCDs when connected Live to Earth Loud Continuity Buzzer 2 Pole Phase Rotation Test Built in Proving Test to Comply with HSE GS38, 12b Conforms fully to BSEN 61243-3 : 2014 LCD and LED Voltage Indication Polarity Test
TIS 819
Single Pole Live Side Test Fast Single handed Testing on 13A Sockets Auto Power On / Off, Torch Light & IP64 Low Battery Warning Complete with Padded Case Heavy Duty Lead Rugged Rubberised Case and Grip
Indicates presence of Voltage with Dead or Missing Battery
Voltage Tester 12V - 690V AC / DC
SPECIAL FUNCTIONS
2 YEAR
Voltage Range: 12, 24, 50, 120, 230, 400 & 690 Volts Automatic Polarity Indication Frequency Range 0-60Hz IP 54 & Shock proof Conforms to BSEN 61243-3:2014 Conforms to H.S.E. GS 38 Works without batteries CAT lll 600V & CAT lV 300V
TIS PU1
WARRANT Y
COMPLIANT WITH BSEN 61243-3: 2014 COMPLIANT WITH H. S. E. GS38
Proving Unit for all Voltage Testers 0 - 690V
The TIS PU1 is a new product we have introduced at a very competitive price, to ‘prove’ AC/DC voltage testers from 0 - 690 Volts, this includes our very own range of voltage testers. The unit is very easy to use, simply connect the probes onto the two connectors of the PU1 and press the voltage tester down and all the lights will illuminate including any accoustical tone for voltage / continuity. A low battery warning device is fitted to the PU1. The unit is fully compliant to the GS38 requirements.
SPECIAL FUNCTIONS
Compliant to GS38 Proves all Voltage Testers 0 - 690V Ideal for use with all TIS Voltage Testers and any other Voltage Tester Low Battery Indication Supplied with 6 x AA Alkaline Batteries Built in On / Off Switch Rugged Housing with easy opening battery cover
01274 752 407
01274 870 175
2 YEAR
WARRANT Y
GS38 COMPLIANT
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
17
High Performance, High Precision & High Accuracy TIS 849
1000V AC/DC LCD, LED, Audible & ‘Shaker’ Voltage and Continuity Tester with Built-in Non-Contact / Contact Voltage Detector, 30mA RCD Test & RST 3-Phase Rotation Detection, Trms
For Full List of Features please see page 19
TIS 859
EN: 61010-1-2-031
CONFORMS TO
CAT III 1000V
CAT IV 600V
BSEN 61243-3: 2014
2 YEAR
WARRANT Y
1000V AC/DC LCD, LED, Audible & ‘Shaker’ Voltage and Continuity Tester with Built-in Non-Contact / Contact Voltage Detector, 30mA RCD Test & RST 3-Phase Rotation Detection, Trms with Built-in Resistance & Capacitance
For Full List of Features please see page 19
TIS 829
EN: 61010-1-2-031
EN: 61010-1-2-031
EN: 61010-1-2-031
CONFORMS TO
CAT III 1000V
CAT IV 600V
BSEN 61243-3: 2014
2 YEAR
WARRANT Y
Replacement Test Lead Set for the TIS 849 and TIS 859
TIS 849
TIS 859
For Video Demonstration
TIS 829
18
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 849
TIS 859
Removable and fully replaceable shuttered test leads (TIS 829)
Trms sensing of voltage
Indicates by LED with or without battery power up to 1000V AC / DC
Built in non-contact and contact voltage detector with signal strength indication
Will not trip RCDs even when testing with or without battery power
ACV frequency response 45Hz - 65Hz
IP65 rated, in compliance with BSEN 61243-3: 2014
Conforms fully with HSE GS38
Low battery warning
Complete with padded carrying case and batteries
Audible continuity function with LED indication
30mA RCD Test button
LCD and LED 1000V AC/DC indication of Voltage
Built in backlight and flashlight
RST, 3 phase rotation detection
Shaker, vibration to indicate presence of voltage, above 50V
Audible LED and LCD indication of continuity
Resistance range 1.99Ω, 19.99Ω, 199.9kΩ, and 1000kΩ
-
Capacitance range 199.9ɥF and 1999ɥF
-
FEATURES
See our online video demonstration
Simply scan the QR code to the right Or search for ‘Test Instrument Solutions’ on 01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
19
TIS BKIT
Safety Lockout Kit
KIT CONTENTS
Lockout Pouch Lockout Dielectric Hasp Lockout Padlock Pin Out MCB Lockout Pin In MCB Lockout MCB Lockout-Red Writing Pen with Eraser For Tags Lockout Tag
TIS EKIT
2 YEAR
WARRANT Y
Safety Lockout Kit
KIT CONTENTS
Lockout Pouch Lockout Dielectric Hasp Dielectric Lockout Padlock Pin Out MCB Lockout Pin In MCB Lockout MCB Lockout-Red / with thumb screw Writing Pen with Eraser For Tags Lockout Tag
2 YEAR
WARRANT Y
TIS TAG Pack of 10 Lock off Tags
TIS NT1 No Tool MCB Lock
TIS NH1 Nylon Hasp
20
01274 752 407
TIS SH1 Steel Hasp
01274 870 175
TIS PEN Pack of 2 Pens
TIS UL3 Universal 3 Phase Lock
TIS PO MCB Pin Out
TIS PI MCB Pin In
TIS LY1 Yellow Steel Lock
TIS LB1 Blue Steel Lock
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 1900
Digital Thermal Image Camera
Thermal image cameras are designed to make your work easier, more productive and effective. 80 X 80 resolution at 50Hz for real-time capture; temperature range from -20°C to 350°C (-4°F to 662°F), 32x continuous zoom, picture-in-picture, voice comment recording and text annotation on images. Hot/cold spot marker automatically finds the hottest and coldest spots. It includes memory card, lithium polymer battery & power supply and usb cable. All this and one hour video recording too!
BASIC FUNCTIONS
RANGE
-20°C to +150°C 0°C to +350°C >6000 Pictures Standard Mpeg-4 encode 1280 x 960 @ 30fps
Object Temperature Storage Jpeg Video Storage
ACCURACY
±2°C or 2% of rdg ±2°C or 2% of rdg Full Infrared
Colour Alarms
Picture-in-Picture
Full Visible Light
*For a comprehensive list of all the specification please see the TIS 1900 4 page flyer
SPECIAL FUNCTIONS High Resolution IR Images 6,400 pixels (80 x 80) infrared resolution Visible Light Digital Camera 5 Megapixels digital camera resolution with flash provides sharp images regardless of lighting conditions Picture in Picture Displays thermal image super-imposed over a digital image LED Flashlight Allows the visual camera and fusion to be used in poorly lit environments Wide Temperature Range From -20°C to +350°C targeting electrical and industrial applications
2 YEAR
WARRANT Y
±2% Accuracy Reliable temperature measurement Thumbnail view Easy to view and analyze images quickly Audio recorded with the video images A speaker to listen to audio recorded with the video image up to one hour video recording
EMC EN: 61326-1 EN: 61010-1
Complete with Free Reports Software
GENERAL CHARACTERISTICS Weight: 500g Size: 224mm x 77mm x 96mm STANDARD ACCESSORIES Infrared Camera with Lens Micro SD Card Earphone Adapter Battery USB Cable Software HDMI Cable Gift Box
Li-ion Rechargeable Battery Lasts >4 hours continuous use; replaceable HDMI High resolution video output 8GB Micro SD Card Stores >6000 images Copy to USB Easy upload images from camera to USB memory card Area (Min/Max) Mode Shows the minimum or maximum temperature reading in the selected area
Other Digital Thermal Imaging & Boroscope Cameras
01274 752 407
THT 70
Page 70
THT 60
Page 70
THT 46
Page 71
THT 33
Page 72
HTB500
Page 73
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
21
Multimeter Selection Guide FEATURES
part of
ELITE - RANGE
TIS 258
TIS 201
TIS 280
TIS E217
TIS E227
-
-
-
-
-
-
-
-
-
-
-
2000
4000
4000
6000
20000
-
-
-
-
-
-
-
-
DC Voltage AC Voltage DC Current AC Current Resistance Ω Capacitance Frequency Duty Cycle Temperature Auto Ranging Manual Ranging TRMS Bar Graph Back Light Display Count Max / Min Peak Hold Data Hold NCV Auto Power Off
For Full Specification, Features and Accuracy please see pages:
22
TIS 258
Page 23
TIS 201
Page 23
TIS 280
Page 23
TIS E217
Pages 24/25
TIS E227
Pages 24/25
Feature Chart (E217 & E227)
Page 25
TIS 2FLK
Page 44
TIS 3TLK
Page 44
TIS 4TL
Page 44
TIS 15 & TIS 25
Page 45
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 258
Digital Multimeter with Temperature
2 YEAR
Robust “pocket size” digital multimeter with AC/DC voltage 500V AC/DC current 200µA to 10A, resistance to 20MΩ, -20˚C to 750˚C, data hold, diode test, continuity buzzer, rubber boot and built in stand, 2000 count LCD display, with backlight.
BASIC FUNCTION Maximum Display Basic Accuracy DC Voltage AC Voltage DC Current AC Current Resistance Temperature Range
TIS 201
RANGE
2000 Counts 0.5% 200mV - 500V 200mV - 500V 200µA - 10A 200µA - 10A 200Ω - 20MΩ -20°C - 750°C, -4°F - 1382°F
WARRANT Y
SPECIAL FUNCTIONS
IEC 61010
Diode Test Continuity Data Hold Back Light Auto Power Off Manual Range Power by 9V Battery x 1
CAT II 600V EMC & LVD EN: 61010-1
EN: 61326 EN: 61010-2-031
Pocket Size, Auto-Ranging Multimeter and Temperature
The TIS 201 is a pocket size auto-ranging digital multimeter which is packed with features which include temperature °C / °F, -20°C to 1000°C, -4°F to 1832°F, a thermocouple and measuring ranges which include AC/DC voltage, AC/DC current, resistance, capacitance, frequency, duty cycle, diode test, plus a 4000 count digital display, data hold, backlit display, continuity buzzer all in a rugged protected case and fused on all ranges.
BASIC FUNC. RANGE DC Voltage AC Voltage
400mV/4V/40V/400V/600V 4V/40V/400V/600V 400µA/4000µA/40mA DC Current 400mA/10A 400µA/4000µA/40mA AC Current 400mA/10A 400Ω/4kΩ/40kΩ/400kΩ Resistance 4MΩ/40MΩ 5nF/50nF/500nF/5uF/50uF Capacitance 100uF Frequency 0 ~ 10MHz Duty Cycle 1% - 99% Temperature ˚C -20˚C to 1000˚C Temperature ˚F -4˚F to 1832˚F
TIS 280
2 YEAR
WARRANT Y
SPECIAL FUNCTIONS
ACCURACY
±(0.5%+3d) ±(1.2%+5d) ±(1.0%+5d) ±(2.0%+10d) ±(1.2%+5d) ±(2.5%+10d)
±(0.8%+5d)
4000 Count Display Auto-Ranging AC / DC Voltage AC / DC Current Resistance Capacitance Frequency EMC & LVD EN: 61010-1
±(3.0%+5d) ±(1.5%+5d) ±(2.0%+2d) ±(2.0%+2d) ±(2.0%+2d)
Temperature Duty Cycle Diode Test Continuity Buzzer Backlit Display Rugged Rubberised Case Data Hold
EN: 61326 EN: 61010-2-031
EN: 61010-1-2-031 CAT III 600V
GENERAL CHARACTERISTICS Power: 2 x 1.5V AAA Batteries Weight: 202g Size: 150mm x 74mm x 41mm
Auto-Ranging Digital Multimeter with Capacitance, Frequency and Temperature
The TIS 280 is packed with features at a very affordable price which includes resistance up to 40M ohm, autoranging, bar graph display, 4000 count display, capacitance to 4000µF, frequency to 10MHz, temperature -20˚C to 1000˚C, cat iv 600V, non contact voltage detector, full overload protection, rel function, max/min function, auto power off, back lit display. All this in a rugged rubberised double injection moulded case with a built in stand.
BASIC FUNC. RANGE DC Voltage AC Voltage
DC Current AC Current Resistance Capacitance Frequency Duty Temperature
400mV/4V/40V/400V/1000V 400mV/4V/40V/400V/750V 400µA/4mA/40mA/400mA 10A 400µA/4mA/40mA/400mA 10A 400Ω/4kΩ/40kΩ/400kΩ 4MΩ/40MΩ 40nF/400nF/4µF/40µF/400µF/4000µF 0.1Hz - 10MHz 0.1% - 99.9% -20˚C to 1000˚C
GENERAL CHARACTERISTICS Power: 9V Battery Weight: 350g Size: 92mm x 188mm x 50mm
01274 752 407
ACCURACY SPECIAL FUNCTIONS ±(0.5%+2d) ±(0.8%+2d) ±(0.8%+2d) ±(1.2%+2d) ±(1.5%+2d) ±(3.0%+2d) ±(1.2%+2d)
Auto & Manual Ranging Auto Power Off Bar Graph Display 4000 Count LCD Display 600V CAT IV Non Contact Voltage Low Battery Indication
±(3.0%+5d)
01274 870 175
Max / Min Rel Function Backlight Display Data Hold Diode Test hfe Test Overload Protected
2 YEAR
±(0.5%+2d) ±(2.0%+2d) ±(2.0%+2d)
STANDARD ACCESSORIES Test Leads Thermocouple
WARRANT Y
EN: 61010-1
EN: 61010-1
CAT IV 600V
CAT III 1000V
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
23
TIS E217
Electrical Multimeter
SPECIAL FUNCTIONS
3 - 5/6 Digits, 6000 Counts, Large easy to read LCD Display EMC: EN 61326-1 Fast Measurements, 5/Sec; Fully Auto-Ranging (EN55022, EN61000-3-2/-3 True RMS AC Conversion & Intelligent Auto Power Off & EN61000-4-2/-3/-4/-5/-6/-8/-11) Data Hold, Diode Tester & Relative Zero Mode Records Max/Min Readings & Calculates Average Readings over time VFD V & Hz Fundamental Readings of most Variable-Frequency-Drives Paper white Back-Lit LCD Display BeepLitTM Continuity. Features Audible Beep & Visible Backlight Effects WARRANT Y Non-Contact EF-Detection (NCV) with Hi/Lo Selectable Sensitivities Probe-Contact EF-Detection for more precise indication of Live 3φ-Rotation-R (Regular-sensitivity mode) for Supply Systems (Probe-contact) 3φ-Rotation-M (Hi-sensitivity mode) for Motors (Probe-contact)
5 YEAR
AutoV LoZ Feature. Automatic DC & AC 1000V Selection with Low Initial Impedance to Drain Ghost Voltages
Please see page 25
DC/AC V Ranges: 600.0mV to 1000V opposite for a full Ohms Ranges: 600.0Ω to 60.00MΩ specification of the TIS E217 Cx Ranges 2000nF to 10.00mF for Start & Run Motor Capacitors Line Level Frequency Ranges 99.99Hz to 50.00kHz DC/AC A Ranges 6.000A to 10.00A (20A for 30s / 5 mins cool down) DC/AC µA Ranges 200.0µA to 2000µA Type-K Temperature Readings -400C to 4000C or -400F to 7520F Beep-Jack™ Input Warning against improper A-Terminal Plug In Rugged Fire Retarded Housing COMPLETE WITH Replaceable Protective Holster with Probe-Holders & Tilt-Stand Calibration Certificate Batteries and Fuses Access Door with Optional Magnetic Hanger Transient Protection up to 6kV 1.2/50µs Lightning Surge LVD: EN61010-1/-2-030/-2-033, CAT-II 1kV, CAT-III 600V & CAT-IV 300V EMC: EN61326-1: 2013
TIS E227
part of
ELITE - RANGE
Professional Multimeter
SPECIAL FUNCTIONS
3 - 5/6 Digits & 4 - 1/2, 20,000 Counts Max, Large easy to read LCD Display Nominal 5/Sec Fast Measurements; Fully Auto-Ranging 61 Segment Analog Bar-graph Updates 60/Sec EMC: EN 61326-1 Paper white Back-Lit LCD Display (EN55022, EN61000-3-2/-3 Dual Digital Display AC + Hz Readings & EN61000-4-2/-3/-4/-5/-6/-8/-11) AC True RMS Conversion & Intelligent Auto Power Off Data Hold, Diode Tester & Relative Zero Mode Crest (Peak Hold) Max/Min Readings COMPLETE WITH High-Update Record Max/Min Readings Update Intervals DC’s 100ms / AC’s 120ms Calibration Certificate BeepJackTM Input Warning against improper plug in to µAmA/A Terminals VFD V & VFD-Hz Measures Fundamental V & Hz of most Variable-Frequency-Drives AC/DC Voltage Ranges 200.00mV to 1000.0V Best Basic DCV accuracy up to 0.09% Please see page 25 ACV Bandwidth up to 5kHz opposite for a full Ohms Ranges 200.00Ω to 20.000MΩ specification of the TIS E227 nS Range 60.00nS TM BeepLit Continuity. Features Audible Beep & Visible Backlight Effects Frequency Ranges 9.999Hz to 100.0kHz AC/DCµA, mA & A Ranges 200.00µA to 10.000A Capacitance Ranges 20.00nF to 20.00mF Type-K Temperature Readings -40.00C to 1090.00C; Selectable 0F Readings Optional Purchase Magentic Hanger Rugged Fire Retarded Casing with Battery and Fuse Access Door Replaceable Protective Holster with Probe-Holders & Tilt-Stand WARRANT Y HBC 1kV Fuses Protected on µAmA/A Terminals Transient Protection up to 8kV 1.2/50µs Lightning Surge LVD Meets: EN61010-1/-2-030/-2-033, CAT-III 100V & CAT-IV 600V EMC: EN61326-1: 2013
5 YEAR
part of
ELITE - RANGE
High Performance, High Precision & High Accuracy 24
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
E217 & E227 MULTIMETER FEATURE CHART ELITE - RANGE
TIS E217
TIS E227
3 - 5/6 6000 Count
4- 1/2 20,000 Count
61 Segment Analog Bar-graph Updates 60/Sec
-
Dual Digital Display AC + Hz Readings
-
AC TRMS Conversion
Intelligent Auto Power Off
Date Hold
Relative Zero Mode
A only
-
Auto V LoZ Feature. Auto DC & AC 1000V Selection with low initial to drain ghost voltages
-
Records Max/Min Readings & Calculates Avg Reading
-
High-Update Record Max/Min Readings, Update Intervals DC’s 100ms / AC’s 120ms
-
VFD V & VFD-Hz Measures Fundamental V & Hz of most Variable-Frequency-Drives
Back Lit Display
-
Ohms Range 200.00Ω to 20.000MΩ
-
Ohms Range 600.00Ω to 60.000MΩ
-
600mV to 1000V
3phase Mains Rotation
-
3phase Motor Rotation
-
Non Contact Voltage (NCV) Hi/Lo Sensitivity Probe Contact for precise detection
-
Best Basic DCV accuracy up to 0.09%
-
ACV Bandwidth up to 20kHz
-
-
Capacitance Ranges 20.00nF to 20.00mF
-
BeepLitTM Continuity. Features Audible Beep & Visible Backlight Effects
-
99.99Hz to 50Hz
200µA to 2000µA
-
6kV
CAT-II 1kV CAT-III 600V CAT-IV 300V
EMC: EN61326-1: 2013
Diode Test
FEATURES
3 - 5/6 Digits & 4 - 1/2, 6000 / 20,000 Count, Large LCD Display Nominal 5/Sec Fast Measurement; Fully Auto-Ranging
BeepJackTM Input Warning against improper plug in to µAmA/A Terminals Crest (Peak-Hold) Max / Min Readings
nS Range 60.00nS
AC/DC Voltage Ranges 200.00mV to 1000.0V
CX Ranges 2000nF - 10mF for Start & Run Motor Capacitors
Frequency Ranges 9.999Hz to 100.0kHz AC/DC µA, mA & A Ranges 200.00µA to 10.000A Temperature Readings -400C to 4000C or 0F Transient Protection up to 8kV
LVD Meets EN61010-1/61010-2-032/61010-2-033 to Measurement: CAT-III 1000V & CAT-IV 600V
High Performance, High Precision & High Accuracy 01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
25
part of
Clamp Meter Selection Guide FEATURES
DC Current AC Current DC Voltage AC Voltage Earth Leakage Resistance Ω Display Count Capacitance Frequency Hall - Effect Jaw Size Amp Tip™ In Rush Current TRMS Crest Mode Phase Rotation Motor Rotation Temperature Max / Min Peak Hold Data Hold Record Max Min Avg Back Light Flash Light HVAC Flame Sensor
ELITE - RANGE
TIS 418
TIS 438
TIS 518
TIS 560
TIS E237
TIS E247
TIS E257
-
-
-
-
-
-
-
-
-
-
-
-
6000
6000
2000
6000
6000
6000
6000
-
-
-
-
-
-
-
-
Ø26mm
Ø40mm
Ø26mm
Ø31mm
Ø30mm
Ø35mm
Ø51mm
-
-
-
-
-
-
-
-
-
-
AC
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
-
Max
-
-
-
-
-
-
-
-
-
-
-
-
-
-
For Full Specification, Features and Accuracy please see pages: TIS 418
Page 27
TIS 438
Page 27
TIS 518
Page 27
TIS 560
Page 30
TIS E237
Pages 28/29
TIS E247
Pages 28/29
TIS E257
Pages 28/29
F3000 26
01274 752 407
Page 75 01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 518
600A AC Auto-Ranging Clamp Meter
The TIS 518 is part of our range of digital auto ranging clamp meters. This unit has many features, including a non contact voltage detector, plus AC/DC voltage, AC current, resistance, continuity buzzer, max hold, data hold, diode test, auto power off, jaw work light and display light. The TIS 518 is an ideal instrument for the everyday electrician / maintenance man.
BASIC FUNCTIONS RANGE
200mV/2V/20V/200V 600V 2V/20V/200V 600V 2A/20A 200A 600A 200Ω/2kΩ/20kΩ/200kΩ/2MΩ 20MΩ
DC Voltage AC Voltage AC Current Resistance
GENERAL CHARACTERISTICS Power: 3 x 1.5V AAA Batteries Weight: 238g Size: 218mm x 78mm x 35mm
TIS 418
ACCURACY ±0.8%+2d ±1.0%+2d ±1.0%+5d ±1.2%+5d ±3.0%+10d ±2.5%+10d ±1.5%+5d ±1.2%+2d ±2.0%+5d
SPECIAL FUNCTIONS
2000 Count Display Jaw Opening Ø26mm Auto / Manual Ranging Auto Power Off Diode Test Continuity Buzzer Max Hold Data Hold Backlit Display Work Light Non Contact Voltage
STANDARD ACCESSORIES Carrying Case Test Leads
2 YEAR
WARRANT Y
EMC & LVD EN: 61010-1
EN: 61326 EN: 61010-2-031
EN: 61010-1-2-031 CAT III 600V
600A AC/DC Auto-Ranging Clamp Meter
The TIS 418 is a 600A AC/DC clamp meter which is supplied with a host of features, for the everyday electrician or maintenance electrician. These include AC/DC current, frequency, capacitance, resistance, duty cycle, temperature -20°C to 1000°C, complete with thermocouple. Other features include max/min hold, auto power off, auto ranging, continuity buzzer, data hold, work light, back light and non contact voltage test.
BASIC FUNC. RANGE DC Voltage AC Voltage DC Current AC Current Resistance Capacitance Frequency Duty Cycle
Temperature
600mV/6V/60V/600V 6V/60V/600V 60A/600A 60A/600A 600Ω/6kΩ/60kΩ/600kΩ/6MΩ/60MΩ 40nF/400nF/4uF/40uF/400uF/4000uF 0 ~ 10MHz 0.1% ~ 99.9% -20°C ~ 1000°C -4°F ~ 1832°F
GENERAL CHARACTERISTICS Power: 3 x 1.5V AAA Batteries Weight: 239g Size: 218mm x 78mm x 35mm
TIS 438
SPECIAL FUNCTIONS
ACCURACY ±0.7%+2d ±0.8%+3d ±3.0%+6d ±2.5%+6d ±1.2%+2d ±4.0%+5d ±1.5%+5d ±3.0% ±2.0%
STANDARD ACCESSORIES Carrying Case Test Leads Thermocouple
6000 Count Display Jaw Opening Ø26mm Auto / Manual Range Auto Power Off Max / Min Hold Data Hold Non Contact Voltage Test AC/DC Current and Voltage Continuity Buzzer Resistance Capacitance Frequency Temperature -20°C - 1000°C Duty Cycle and Diode Test
2 YEAR
WARRANT Y
EMC & LVD EN: 61010-1
EN: 61326 EN: 61010-2-031
EN: 61010-1 CAT II 1000V
1000A AC/DC TRMS Auto-Ranging Clamp Meter with Inrush Reading
Our TIS 438 is designed and manufactured to the very latest standards and features 1000A AC/DC current, AC/DC voltage, resistance, capacitance, frequency from the clamp, logic frequency and duty cycle, 6000 count display, TRMS, inrush current reading, continuity buzzer, work light, back light, non contact voltage detection, relative measurement and auto power off. The TIS 438 is packed with features for the professional electrician.
BASIC FUNCTIONS DC Voltage AC Voltage DC Current AC Current
RANGE
60mV/600mV/6V/60V/600V 60mV/600mV/6V/60V/600V 60A/600A/1000A 60A/600A/1000A 600Ω/6kΩ/60kΩ/600kΩ Resistance 6MΩ/60MΩ 10nF/100nF/10uF/100uF/1mF Capacitance 10mF/100mF Frequency (from Clamp) 0 ~ 10MHz Frequency (AC Voltage) 0 ~ 10MHz Logic Frequency 0 ~ 10MHz Duty Cycle 10% ~ 90% STANDARD ACCESSORIES Carrying Case Test Leads
01274 752 407
ACCURACY ±0.7%+3d ±0.8%+3d ±2.5%+6d ±2.5%+6d ±0.8%+3d ±4.0%+5d ±1.5%+5d ±1.5%+5d ±0.5%+3d ±3.0%
GENERAL CHARACTERISTICS Power: 1 x 9V 6F22 Battery Weight: 386g Size: 238mm x 92mm x 50mm
01274 870 175
SPECIAL FUNCTIONS
6000 Count Display Jaw Opening Ø40mm Auto / Manual Range Auto Power Off Relative Mode Diode Test Continuity Buzzer Max / Min Hold Data Hold Backlit Display Work Light TRMS Inrush Current Non Contact Voltage
2 YEAR
WARRANT Y
EMC & LVD EN: 61010-1
EN: 61326 EN: 61010-2-031
EN: 61010-1-2-031 CAT III 1000V
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
27
TIS E237
Digital Clamp Meter 600A AC with Amp™Tip Jaws
SPECIAL FUNCTIONS
VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives AmpTipTM Low-Current-Range Calibrated at Jaw-Tip for Slim-Conductors AC True RMS Voltage and Current Functions Fast 80ms PEAK-RMS Mode to Capture In-Rush Currents 3φ-Rotation-R for MAINS Supply (Probe-contact) 3φ-Rotation-M (Hi-sensitivity mode) for Motors (Probe-contact) DCµA Ranges 200.0µA to 2000µA (via leads) for HVAC Flame Sensors Cx Ranges 200.0µF to 2500µF for Start & Run Motor Capacitors
part of
VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives 3 - 5/6 Digits, 6000 Counts, Large LCD Display 35mm Conductor Size Hall-Effect 600A DC/AC Jaws AC + DC, AC True RMS Voltage and Current Functions Fast 80ms PEAK-RMS Mode to Capture In-Rush Currents DCµA Ranges 200.0µA to 2000µA (via leads) for HVAC Flame Sensors DC + ACA Ranges 60.00A to 600.0A + AmpTipTM DC + ACA 60.00A Range Cx Ranges 200.0µF to 2500µF for Start & Run Motor Capacitors
part of
WARRANT Y
COMPLETE WITH Calibration Certificate
ELITE - RANGE
Digital Clamp Meter 1000A AC/DC with Amp™Tip Jaws
SPECIAL FUNCTIONS
5 YEAR
EMC: EN 61326-1 (EN55022, EN61000-3-2/-3 & EN61000-4-2/-3/-4/-5/-6/-8/-11)
Please see page 29 opposite for a full specification of the TIS E247
TIS E257
ELITE - RANGE
Digital Clamp Meter 600A AC/DC with Amp™Tip Jaws
SPECIAL FUNCTIONS
COMPLETE WITH Calibration Certificate EMC: EN 61326-1 (EN55022, EN61000-3-2/-3 & EN61000-4-2/-3/-4/-5/-6/-8/-11)
Please see page 29 opposite for a full specification of the TIS E237
TIS E247
5 YEAR
WARRANT Y
VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives 51mm Conductor Size Hall-Effect 1000A AC/DC Jaws 51mm Conductor Size Ultra-Slim 1000A AC Jaws Record Max/Min/Avg Mode (Auto-Ranging) Fast 80ms PEAK-RMS Mode to Capture In-Rush Currents 5ms Crest Mode to capture instantaneous +Peak & -Peak DCµA Ranges 200.0µA to 2000µA (via leads) for HVAC Flame Sensors DC + ACA Ranges 60.00A to 1000A + AmpTipTM DC + ACA 60.00A Range
5 YEAR
WARRANT Y
COMPLETE WITH Calibration Certificate EMC: EN 61326-1 (EN55022, EN61000-3-2/-3 & EN61000-4-2/-3/-4/-5/-6/-8/-11)
Please see page 29 opposite for a full specification of the TIS E257
part of
ELITE - RANGE
High Performance, High Precision & High Accuracy 28
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
CLAMP METER FEATURE CHART ELITE - RANGE
FEATURES
VFD-V & Hz for fundamental V/Hz of most Variable-Frequency-Drives Fast Measurement updates 3 - 5/6 Digits, 6000 Count, Large LCD Display
TIS E237
TIS E247
TIS E257
5/Sec
5/Sec
3/Sec
-
35mm 600A DC/AC
51mm 1000A DC/AC
30mm 600A
30mm 600A
-
AmpTipTM Low-Current-Range Calibrated at Jaw-Tip for Slim-Conductors
True RMS Voltage and Current Functions
AC
AC + DC, AC
AC + DC, AC
600V AC/DC
600V AC/DC
1000V AC/DC
Auto Power Off
Data Hold
Record Max/Min/Avg Mode (Auto-Ranging)
Relative Mode (Auto-Ranging) with DC-Zero Mode on DCA, DC + ACA Ranges
Fast 80ms PEAK-RMS Mode to Capture In-Rush Currents
Back-Lit, Easy to Read LCD Display
5ms Crest Mode to capture instantaneous +Peak & -Peak
-
-
Flash Light for easy operation in dim areas
-
-
Non-Contact EF-Detection (NCV)
Probe-Contact EF-Detection for more precise indication of Live
3φ-Rotation-R for MAINS Supply (Probe-contact)
3φ-Rotation-M (Hi-sensitivity mode) for Motors (Probe-contact)
Type-K Temperature Readings -40.00C to 4000C or -40.00F to 7520F selectable
DCµA Ranges 200.0µA to 2000µA (via leads) for HVAC Flame Sensors
60.00A to 1000.0A 60.00A to 1000.0A 60.00A to 1000.0A
Conductor Size Hall-Effect DC/AC Jaws Conductor Size Ultra-Slim AC Jaws
Input Protection on General Functions
DC + ACA Range
-
DCA Range
-
ACA Range
60.00A to 600.0A
60.00A to 600.0A 60.00A to 600.0A 60.00A to 600.0A
-
600.0V
1000V
DCV Range
600.0V
600.0V
1000V
ACV Range
600.0V
600.0V
1000V
Ohms Ranges 60.00kΩ
Cx Ranges 200.0µF to 2500µF for Start & Run Motor Capacitors
Diode Test & Fast Audible Continuity
Line Level ACV Frequency 5.00Hz to 999.9kHz
Soft Carrying Pouch
Rugged Fire Retarded Casing with Battery Access Door
Transient Protection up to 8kV 1.2/50µs Lightning Surge
6kV
6kV
8kV
CATIII 600V CATIV 300V
CATIII 600V CATIV 300V
CATIII 1000V CATIV 600V
DC + ACV Range
LVD: EN61010-1/61010-2-032/61010-2-033 to CAT-III 1000V & CAT-IV 600V EMC: EN61326-1 (EN55022, EN61000-3-2/-3 & EN61000-4-2/-3/-4/-5/-6/-8/-11)
High Performance, High Precision & High Accuracy 01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
29
TIS 560
Earth Leakage Clamp Meter 0.001mA to 60A AC
The TIS 560 is a highly sensitive earth leakage clamp meter from 0.001Ma which will also read up to 60A AC, having a large jaw opening of ø31mm for such a compact, pocket size clamp meter. For a full list of features and specifications please see the sections below, marked ‘basic functions’ and ‘special functions’.
BASIC FUNCTIONS RANGE AC Current Resolution AC Current Resolution AC Current Frequency Max permitted input
GENERAL CHARACTERISTICS Power: 2 x 1.5V AAA Batteries Weight: 136g Size: 176mm x 59mm x 29mm
TIS 455
ACCURACY
2mA ±2% + 5d 0.001mA ±2% + 5d 20mA ±2% + 5d 0.01mA ±2% + 5d 60A <50A ±2% + 5d 50 to 60Hz >50A ±3% + 5d 120% full range for 60 seconds
2 YEAR
EN: 61010-1 CAT III 600V
SPECIAL FUNCTIONS
High Sensitivity from 0.001mA Data Hold Jaw Opening Ø31mm Measures up to 60A AC 2000 Count LCD Display Low Battery Warning Pocket Size Zipped Padded Case
For Video Demonstration
WARRANT Y
AC Line Splitter with Earth Leakage Measurement
The TIS 455 Line Splitter is an ideal accessory when using a clamp meter to measure AC current as it splits the live conductor from the neutral and earth. Ideal when PAT testing to measure loads of individual equipment, including Earth Leakage
2 YEAR
SPECIAL FUNCTIONS
WARRANT Y
Allows for Easy AC Current Measurement using a Clamp Meter on 2 or 3 Wire Power Cords AC Voltage to 250 Volts, AC Current to 13A Allows Measurement of Earth Leakage Enables safe measurement of Current without the need to separate conductors
For Video Demonstration
Ideal for use with the TIS 518, 418, 438, 237, 247 & 257 Clamp Meters. Plus TIS 560 Earth Leakage Clamp Separates the Live Conductor from the Neutral and Earth Allows Voltage Measuring on 13A Sockets
EMC & LVD EN: 61010-1
EN: 61326 EN: 61010-2-031
Various Test Leads, see Page 44
Various Carrying Cases, see Page 45
30
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Phase, Fuse, Socket & Specialised Test Equipment
01274 752 407
TIS 415
Page 32
TIS 870
Page 32
TIS 1000
Page 32
TIS 1005
Page 33
TIS USB1
Page 33
TIS 888
Page 33
TIS 1040
Page 34
TIS LD40
Page 34
TIS 880
Page 35
TIS 1100
Page 35
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
31
TIS 415
Phase Rotation Plus Non Contact/Contact Motor Rotation Tester
The TIS 415 determines the rotary field of three Phase systems and rotational direction of three Phase motors, using non-contact or contact technology. Simply place the TIS 415 on top of the motor with the base of the instrument facing the shaft of the motor, press the “green” button and the magnetic field of the motor will be detected along with its clock wise or anti-clock wise rotation. Alternatively connect the TIS 415 with the test leads to the motor terminals, give the shaft a quarter turn to the right and the rotational field will also be displayed.
SAFETY SPECIFICATIONS
Meets DIN VDE0411, IEC61010, VDE0413-7 Maximum Operating Voltage 400V for All Ranges CAT III, 300V Current Consumption Max 20mA
GENERAL CHARACTERISTICS Power: 6F22 / 9V Weight: 150g Size: 124mm x 61mm x 27mm STANDARD ACCESSORIES 2 x AA Batteries Test Leads 3 x Crocodile Clips Zipped Padded Case Rubber Housing
TIS 870
SPECIAL FUNCTIONS Determines Rotary Field of 3 Phase Systems Non-Contact Motor Rotation Contact Motor Rotation Clear and Precise LED Indication Wireless Rotational Chart
EN: 61010-1
2 YEAR
WARRANT Y
EN: 61010-1 CAT III 300V
Circuit Fuse / Breaker Finder with NCV and Socket Test
The TIS 870 features the very latest technology in fuse/breaker location. The advanced microprocessor locates the fuse/breaker with pin-point accuracy by using the very latest second pass technology. Simply plug the transmitter into the circuit to test then pass the receiver over the fuses / breakers. You will hear several tones on various breakers, etc. Then pass over them for a second time when only one of the fuse/breakers will cause the TIS 870 to light up, indicating by tone which is protecting the circuit under test. The TIS 870 also features a non contact voltage tester and the transmitter also acts as a socket tester with “buzzer“.
2 YEAR
WARRANT Y
For Video Demonstration SPECIAL FUNCTIONS Quickly, Easily and Accurately Identifies the Fuse/Breaker Built-in Non Contact Voltage Test “Very cost Built-in Socket Test effective way of Fully Automatic Operation identifying Very Latest 2nd Pass Technology for accurate circuits / breakers” Fuse / Breaker Detection
Rugged Design Two Part Kit: Transmitter and Receiver Verifies presence of AC Voltage Can Locate Breaks in Cables Buzzer and LED Indication
TIS 1000
GENERAL CHARACTERISTICS Power: 1 x 9V MN1604 Battery Weight: 95g Size: 175mm x 45mm x 30mm
13A Socket Tester with Sounder
Designed to test 230V 13A sockets to international standards 61010-1 CATIII 600V in one easy step, simply plug in for visual and audible indication, reliable and easy to use wiring conditions that are included; correct, missing earth, live earth reversal, live neutral reversal, missing neutral*. Simple and easy to use with no maintenance or batteries. *this unit will not indicate neutral/earth reversal
32
01274 752 407
01274 870 175
2 YEAR
WARRANT Y
EN: 61010-1
EN: 61010-1 CAT III 600V
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 1005
Loop Impedance, RCD 30mA Socket Polarity Checker 230V/110V
The TIS 1005 is a pocket size checker for indicating loop impedance, socket polarity and rcd 30mA are all ok. Indication is by led’s and buzzer. It is an ideal unit for initial ‘checking out’ of a 13A socket and will advise if the circuit is ok, needs attention or needs urgent attention, an ideal product for housing associations, landlords, council property departments, shopping centers, electricians, etc.
BASIC FUNCTIONS Nominal Voltage Frequency Range Contact Voltage Range Overload Protection
RANGE 230V AC 110V AC 50Hz - 60Hz <50V AC (Relative to Ground) AC / DC 300V
ACCURACY ±10% ±10%
SPECIAL FUNCTIONS
Earth Loop Check at mains frequency Checks condition of Earth Loop Loop Detection Ranges <1.8Ω, 1.8Ω - 92Ω, >92Ω 30mA RCD Test 3 Coloured LEDs (Green, Amber, Red) give indication of condition Socket Checked against 17 possible fault conditions Microprocessor controlled, with built in self check First Socket Tester to indicate actual fault - Live, Neutral or Earth Simple and Easy to Use, plug in and switch the socket on GENERAL CHARACTERISTICS Weight: 40g Size: 72mm x 78mm x 80mm
TIS USB1
Tests 110V Sockets with Adapter
2 YEAR
For Video Demonstration
WARRANT Y
USB Tester
SPECIAL FUNCTIONS
Input & Output Ports Type A Tests Load at 0.5a, 1a, 2a & 3a Resolution: 0.01mAh Energy: 0 - 1000WH Voltage Range: 4 - 24.00V DC Current Range: 0.05 - 3.00A DC Operational Resistance Measurements Capacity: 0 - 99999mAh CE Approved Q.C. USB 1.0, 2.0, 3.0 Fast Charge Protocol
TIS 888
2 YEAR
WARRANT Y
Multi-function Tone Generator, Cable Tracker and Continuty Tester
SPECIAL FUNCTIONS
Tracks the cables or wires and diagnoses the breaking point Receives the tone signal on the cables or wires (telephone lines) Checks the condition of the working telephone line (clear, ringing or busy) Checks continuity of the cables or wires Sends a Single Solid or a Dual Alternating Tone Complete with Zipped Padded Case 2 YEAR WARRANT Y
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
33
TIS 1040
Lamp and Control Gear Tester
The TIS 1040 ignites all gas filled lamps including low/high pressure vapour lamps, flourescent, low/ high pressure sodium, neon, mercury and metal halide. Other tests carried out include voltage and a unique continuity test using single pole technology. The TIS 1040 also tests ballasts, capacitors, starters, resistors, diodes and photo-cells. A very handy unit for testing new lamps to ensure they are ok before climbing ladders, scaffolding, platforms or cherry pickers!
BASIC FUNCTIONS
RANGE
LAMP TEST Voltage with New Battery Field Strength
approx. 3kV/160kHz 150-170kHz approx. 100µv/m
VOLTAGE TEST Test Range Frequency Test Current
60-250V CA 40-60Hz <200mA
CONTINUITY TEST Dielectric Strength Test Range Test Current
250V CA/CC approx. 0-5MΩ <7µA
GENERAL CHARACTERISTICS Power: 9V MN1604 Alakline Weight: 170g Size: 255mm x 60mm x 40mm STANDARD ACCESSORIES Carrying Case Battery Instruction Manual
2 YEAR
WARRANT Y
EN: 61010-1 CAT III 300V
For Video Demonstration
SPECIAL FUNCTIONS Test Gas Filled Lamps, including: Flourescent Low/High Pressure Sodium Neon Tubes Mercury Lamps Metal Halide Metal Halogen Tests photo-Cells, Ballasts & Starters Voltage Tester Single Pole Single Pole Continuity Test Audible / Visual LEDs Torch Light
TIS LD40
40 Metre Laser Distance Meter
SPECIAL FUNCTIONS
Pythagoras Measurement Single Length, Area and Volume Measurements 0.05M - 40M Measurement Resolution: 0.001M Accuracy: ± 1.5mm Measuring Speed: 0.5 seconds Laser Type: 650nm, Class 2 <1mW 2 YEAR Laser Beam Size: 25mm @ 30M WARRANT Y Battery Life: 10,000 Measurements Auto Power Off Highly Accurate SX10V2 Software Low Battery Warning & Back Lit Display Option to measure from the front or base of the unit Metric or Feet and Inches Measurement Class 2 Laser Product EN 60825-1 : 2007
GENERAL CHARACTERISTICS Power: 2 x AA Alakline Batteries Weight: 45g Size: 122mm x 53mm x 35mm STANDARD ACCESSORIES Carrying Case 2 x AA Batteries Safety Strap Instruction Manual
34
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 880
Network Cable Tester with Built In De-Bug Mode
BASIC FUNCTIONS RANGE (Plaster Board) Minimum 1 Metre Maximum 300 Metre
Cable Length
SPECIAL FUNCTIONS Tests UTP Cable, STP Cable and Coaxial Cable Checks Continuity and Configuration of Wiring with RJ45 Plugs Tests for Open Circuits, Shorts, Miswires, Reversal and Split Pairs Shield detection, Tests a Cables Shield Integrity De-bug Mode Main and Remote Unit allow one person Testing Low Battery Indication Tests T568A, T568B 10 Base-T and Token Ring Cables Identification Plugs (1 & 2) supplied, optional plugs 3-8 available, TIS 880/1D
2 YEAR
WARRANT Y
EMC & LVD EN: 61010-1
TIS 1100
R2, R1 + R2 Socket Adapter
Our TIS 1100 is a must have accessory for any electrician who carries out testing. It eliminates the need to remove the faceplate of the socket from the wall when testing R2, R1 + R2, saving valuable time and expense. The adapter also allows voltage testing from the socket, without having to open the ‘shutters’ of the wall socket.
BASIC FUNCTIONS
Rated Voltage Rated Current Operating Environment Relative Humidity
RANGE
2 YEAR
230V Max 2A Temperature 0oC - 40oC <80%
WARRANT Y
SPECIAL FUNCTIONS
EN: 61010-1
Eliminates the need to remove socket faceplate from wall ‘Speeds Up’ testing of R2, R1 + R2 Enables voltage testing at the wall socket Saves time and money when testing A ‘must have’ for all electricians Robust and Rugged design
01274 752 407
01274 870 175
GENERAL CHARACTERISTICS Weight: 66g Size: 68mm x 62mm x 62mm
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
35
TIS 958
Optical / Accoustical Non-Contact Voltage Detector
The TIS 958 is a multipurpose detector which indicates phase sequence L1, L2, L3 rotation on a 3 phase system without the need to connect test leads to L1, L2 & L3. This is a very safe tester to use, will indicate magnetic field and is a non-contact voltage tester.
“Quick and simple way of checking 3 phase sequence before and after working on a 3 phase system”
GENERAL CHARACTERISTICS Power: 2 x AAA Batteries (supplied) Weight: 55g Size: 155mm x 25mm x 23mm
TIS 934
EN: 61010-1 CAT IV 1000V
IP65
2 YEAR
WARRANT Y
Optical / Accoustical Non-Contact Voltage Detector
The TIS 934 is an optical and accoustical non contact voltage detector that detects ac voltage from 50V - 1000V, HSE recommends that voltages over 50V must not be touched, therefore a voltage detector that detects voltage from 50V is a neccessary purchase. For all other features see special functions below.
SPECIAL FUNCTIONS
Detects 50V - 1000V Built in Self Audible Test Bright LED Light, Loud Buzzer On / Off Button Checks for Cable Breaks Uses Advanced Digital Filter Technology for reliable results CAT IV for Indoor / Outdoor Use, IP65
GENERAL CHARACTERISTICS Power: 2 x AAA Batteries (supplied) Weight: 55g Size: 155mm x 25mm x 23mm
TIS 950
EN: 61010-1 CAT IV 1000V
IP65
2 YEAR
WARRANT Y
Non-Contact Voltage Detector with IP65 Rubber Housing, Vibration and LED Indication
The TIS 950 is a simple, yet very accurate indicator of AC voltage by LED and vibration, having a built in pocket clip and having IP65 approval, a simple screw off cap for battery replacement
GENERAL CHARACTERISTICS Power: 2 x AAA Batteries (supplied) Weight: 45g Size: 150mm x 20mm x 20mm
36
01274 752 407
EN: 61010-1 CAT III 1000V
01274 870 175
IP65
2 YEAR
For Video Demonstration
WARRANT Y
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Environmental Test Equipment
01274 752 407
TIS 1309
Page 38
TIS 1310
Page 38
TIS 770
Page 39
TIS 82
Page 39
TIS 720
Page 40
TIS AP2
Page 40
TIS LP2
Page 40
TIS NP2
Page 40
TIS SP2
Page 40
TIS PC1
Page 40
TIS BODYIR
Page 41
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
37
TIS 1309
Digital Anemometer
Our TIS 1309 digital anemometer will measure a wide range of air velocity including metre per second, feet per minute, kilometer per hour, mile per hour and nautical mile per hour. Plus air flow at cfm, cmm and cms, plus flow area settings. The TIS 1309’s other features include max/min, display backlight, auto power off and low battery indication.
BASIC FUNCTIONS
RANGE
Air Velocity:
ACCURACY
m/s (metre per second) ft/m (feet per minute) km/h (kilometer per hour) mile/h (mile per hour) Knots (nautical miles per hour)
0.40 ~ 30.0 80 ~ 5900 1.4 ~ 108.0 0.9 ~ 67.0
±3.0% ±3.0% ±3.0% ±3.0%
0.8 ~ 58.0
±3.0%
CFM CMM CMS
0 to 99990 0 to 99990 0 to 9999
0 to 9.999ft2 0 to 9.999m2 0 to 9.999m2
Air Flow:
GENERAL CHARACTERISTICS Power: 1 x 9V 6F22 Battery Weight: 200g Size: 165mm x 85mm x 38mm
TIS 1310
STANDARD ACCESSORIES Padded Case Battery User Manual
SPECIAL FUNCTIONS Large LCD Display Built in Vane Backlit Display Max / Min Measurement Data Hold Auto Power Off Measures Air Velocity Measures Air Flow Flow Area Settings Conforms to Part F (Ventilation) of Building Regs
CONFORMS TO Ventilation of Building Regulations : Part F
2 YEAR
WARRANT Y
Digital LED Light Meter & Standard Lux Levels
The TIS 1310 is an LED light meter which will measure LED, daylight, red light, amber, yellow, green, blue and purple light, as well as measuring standard lux/light levels from 0.01 lux (emergency light levels) up to 200,000 lux. The unit has a built in opto-sensor and features max/min/relative value/ peak hold/lux/foot candle measurements with a 3½ digit LCD display with both digital and analogue bar graph readings in a compact hand held housing with tripod capability and zero calibration function. The ideal instrument for the lighting professional, maintenance engineer or electrician.
BASIC FUNCTIONS Max Range Max Resolution Measuring Rate
RANGE
0.01 - 200,000 Lux 0 - 999900 CD (LED) 0.01 Lux / 0.01Fc 0.01 CD 2 times / second
ACCURACY ±3.0% ±(3% + 2d)
2 YEAR
SPECIAL FUNCTIONS
WARRANT Y
LED Measurement Selection:
L1 LED Daylight, L2 LED Red Light L3 LED Amber (Yellow) Light, L4 LED Green Light L5 LED Blue Light, L6 LED Purple Light L7 - L9 Default Standard Lighting
Enables Testing of LED Red Strobe Light 3½ Digit Display Measures Emergency Light Levels 0.01 Lux Measuring Range 0.01 - 200,000 Lux Digital and Bar Graph Readings Auto / Manual Ranging Max / Min Function & Peak Hold Relative Measurement Auto Power Off & Data Hold Compact with Built In Sensor Backlit Display & Low Battery Warning Cosine Corrected & Calibration Zero Function
38
01274 752 407
01274 870 175
EMC & EN
GENERAL CHARACTERISTICS Power: 1 x 9V 6F22 Battery (200 Hour Life) Weight: 200g Size: 165mm x 85mm x 38mm Accessories: Padded Case
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 770
Digital Sound Level Meter
The TIS 770 meets the very latest regulations including IEC 61672-1 Type 2, IEC 651 Type 2 and ANSI S1.1 Type 2. A & C weighting, LCD display with analogue bar graph, fast response, slow response, max hold feature, backlit display, auto-ranging, auto power off. Complete with padded carrying case and sensor muffler.
BASIC FUNCTIONS Measurement Frequency Resolution
RANGE
ACCURACY
30dB - 130dB 30Hz - 8kHz 0.1dB
±1.5dB
2 YEAR
WARRANT Y
SPECIAL FUNCTIONS
LCD Display Analogue Bar Graph A & C Weighting Fast / Slow Response Max Hold Data Hold Auto Power Off Auto & Manual Ranging Low Battery Display Over Range Display Backlit Display 30dB - 130dB 6 Measurement Gears
TIS 82
IEC 61672-1
GENERAL CHARACTERISTICS Power: 4 x 1.5V AAA Batteries Weight: 200g Size: 193mm x 60mm x 29mm
Type 2
IEC 651 Type 2
STANDARD ACCESSORIES Instruction Book Sensor Muffler Padded Case
Non-Contact Infrared Thermometer
The TIS 82 is an ideal 12:1 ratio, Non-Contact Infrared Thermometer which can measure in 0C or 0F, -500C - 8500C or -560F - 15620F with a fast response time of 500ms, large Laser Circular Sight, Hi / Lo Alarm, plus many more outstanding features.
SPECIAL FUNCTIONS
Temperature Range: -50°C - 850°C, -56°F - 1562°F Best Accuracy: ±1.5%, ±1.5°C or ±1.5°F, ±0.5%, ±0.5°C or ±1°F Display Resolution: 0.1 Distance to Spot Size Ratio: 12:1 Response Time (95% Reading): 500ms Spectral Response: 8µm - 14µm
Laser Power: Class 2 (II) operation; Output < 1mW, Wavelength 630 - 670nm
2 YEAR
WARRANT Y
Laser Sighting: Circular Emissivity: 0.10 to 0.95 Adjustable Emissivity (from 0.10 to 0.95) °C / °F Selection Temperature Data Hold Search Max / Min Room Temperature Hi / Lo Alarm Display Back Light Sleep Mode Power by 9V (6F22) x 1
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
39
TIS 720
T1 and T2 Dual Input K-Type Digital Thermometer -200oC to 1372oC
The TIS 720 is a dual input, T1 and T2 k-type digital thermometer that has a temperature range of -200°C up to 1372°C, -328°F up to 1999°F. The extremely low/high temperature range means it is ideal for refridgeration, cold store or high temperature environments such as paint plants / steel production and maintenance applications. For a list of the features please see ‘special functions’ section below.
BASIC FUNCTIONS Centigrade Scale Fahrenheit Scale
RANGE
-60°C to 1372°C -60°C to 200°C -76°F to 1999°F -76°F to -328°F
ACCURACY
2 YEAR
0.1% rdg +1°C 0.1% rdg +2°C 0.1% rdg +2°F 0.1% rdg +4°F
WARRANT Y
GENERAL CHARACTERISTICS Power: 4 x 1.5V AAA Batteries Weight: 240g Size: 160mm x 83mm x 38mm
SPECIAL FUNCTIONS
-200°C to 1372°C / -328°F to 1999°F Dual Input T1 & T2 K-Type (supplied with 2 x Oven Probes) High Accuracy 0.1% reading +1°C Fast Response Time Large LCD Display Max / Min Temerature Readings T1 Measurement, T2 Measurement, T1-T2 Measurement
TIS AP2 K-Type Air Probe
01274 752 407
Adj. Button for Self Checking Calibration Relative Mode to Zero Display Data Hold Back Lit Display Rugged, Rubberised Housing with Stand APO Function Auto Ranging / Auto Power Off
TIS LP2 K-Type Liquid Probe
TIS SP2 K-Type Gas / Air Probe
40
01274 870 175
TIS NP2 K-Type Needle Probe
TIS PC1 K-Type Pipe Clamp
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS BODYIR
Dual Forehead & Ear Medical Infrared Thermometer
The TIS BODYIR Infrared Thermometer is a very simple and non-invasive way to measure a persons temperature and is ideal for pin pointing high temperatures.
SPECIAL FUNCTIONS
Ear Mode Forehead Mode Room / Surface Mode 1 Second Reading C° / F° Fever Alarm Silent Mode Child Mode Recall Last 20 Readings Magnetic Head Cover
For Video Demonstration
BASIC FUNCTIONS
RANGE
ACCURACY
Forehead Mode
35°C to 42.2°C 95°F to 108°F
±0.2°C ±0.4°F
Ear Mode
35°C to 42°C 95°F to 107.6°F
±0.2°C ±0.4°F
Object Mode
0°C to 100°C 32°F to 212°F
±0.1°C ±0.2.0°F
0482
FDA EC REP Wellkang Ltd Suite B, 29 Harley Street London, W1G 9QR, UK
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
41
Various Test Leads & Carrying Cases
42
TIS JUMPTL
Page 43
TIS 172ML
Page 43
TIS 173DB
Page 43
TIS 50
Page 43
TIS 2FLK
Page 44
TIS 3TLK
Page 44
TIS 4TL
Page 44
TIS 25
Page 45
TIS PUK
Page 45
TIS 15
Page 45
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS JUMPTL
Jump Leads with Crocodile Clips
Ideal for use when carrying out insulation testing or continuity testing at a distribution board. Lead Length: 2 x 170mm & 2 x 450mm
TIS 172ML
Universal Mains Lead
The TIS 172ML is a universal mains lead that can be used with most multifunction testers and our own MFT-PRO & MFT-ECO. We have priced this lead set very competitively against other manufacturers prices.
TIS 173DB
Distribution Board Lead Set with Probes and Crocodile Clips
The TIS 173DB is a rugged constructed distribution board lead set, constructed with silicone cable, making it extremely flexible, the set comes complete with probes and rugged strong crocodile clips and is fitted with standard 4mm terminals making it suitable for our own MFT-PRO & MFT-ECO, plus most other test instrumentation.
TIS 50
50M Earth Wander Reel
The 50m earth wander reel is to enable performance of r2 testing and is easy to use, on a quick and simple rewindable reel it has a 4mm terminal to fit the majority of test equipment no matter what manufacturer.
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
43
TIS 2FLK
Fused Test Lead Set
Comprises of test leads, probes, crocodile clips and fuses ideal for all test instruments having 4mm sockets. TEST LEADS MEET VERY LATEST BSEN STANDARDS
TIS 3TLK
Test Lead Kit (unfused)
Comprises of test leads, probes, crocodile clips. Ideal for all test instruments having 4mm sockets, most manufacturers. TEST LEADS MEET VERY LATEST BSEN STANDARDS
TIS 4TL
Test Leads (unfused)
Test leads complete with probes. Ideal for all test instruments having 4mm sockets, most manufacturers. TEST LEADS MEET VERY LATEST BSEN STANDARDS
44
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 25
Large Test Instrument Pouch
The TIS 25 is suitable for our general range of test equipment that does not exceed the following dimensions: 230mm x 170mm x 50mm This case includes a carrying handle and a removeable shoulder strap.
TIS PUK
Dual Instrument Pouch
The TIS PUK is suitable for our range of voltage testers with space for a proving unit or any instrument that does not exceed the following dimensions: 280mm x 80mm x 40mm This Case includes a removeable shoulder strap
TIS 15
Small Test Instrument Pouch
The TIS 15 is suitable for our range of voltage testers or any instrument that does not exceed the following dimensions: 250mm x 70mm x 40mm
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
45
TIS 1901 - 1710
Range of Electrical Installation and Inspection Certificates & TIS 1908 EVSE Test Report TIS 1901
Tel: 01274 752 407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
Domestic & Industrial Electrical Installation Certificate Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
18th
E Domestic & Similar Premises Electrical D Installation Certificate I T 18th I TIS 1903 E O Domestic & Similar Premises Electrical Condition Report D Up to 100A N I T I TIS 1905 O Schedule of Test & Circuit Details NSheets Continuation TIS 1901
Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
For Certification of: New Installation Rewire Addition of one or more new circuits to existing installation Replacement of consumer unit
Tel: 01274 752 407 Fax: 01274 870 175
TIS 1903
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
Domestic & Industrial Electrical Condition Report Up to 100A Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
Requirements for Electrical Installations BS 7671: 2018
Printing errors and omissions excepted
For completion reporting on the condition of an existing electrical installation
Tel: 01274 752 407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
18th
E D I T I TIS 1906 O Minor Works Electrical InstallationN Certificate
TIS 1905
Requirements for Electrical Installations BS 7671: 2018
Printing errors and omissions excepted
For completion reporting on the condition of an electrical installation
Tel: 01274 752 407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
18th
E D I T I TIS 1710 O N
Schedule of Test & Circuit Details Continuation Sheets Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
Printing errors and omissions excepted
To be used for minor electrical work only, which does not include the provision of a new circuit
Tel: 01274 752 407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
Portable Appliance Inspection and Test Records
Printing errors and omissions excepted
TIS 1906
Minor Works Electrical Installation Certificate Requirements for Electrical Installations BS 7671: 2018 (IET Wiring Regulations)
TIS 1710 Printing errors and omissions excepted
Portable Appliance Inspection and Test Records In compliance with IET Code of Practice 4th Edition
TIS 1908
EVSE Test Report
TIS 1814 - 1817
Range of Fire Alarm and Emergency Lighting Books TIS 1816 - Fire Alarm Log Book Compliant to BS5839-1: 2017
Tel: 01274 752407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
CONFORMS TO
TIS 1816
BS 5839, BS 5839-1, H.2, H.3, H.4, H.5, H.7 : 2017
Fire Alarm Log Book BS 5859-1 : 2017
Tel: 01274 752407 Fax: 01274 870 175 Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk
TIS 1817 - Fire Alarm Certificate Book Compliant to BS5839-1: 2017
TIS 1817 Fire Alarm Certificate Book BS 5859-1 : 2017
CONFORMS TO BS 5839, BS 5839-1, H.2, H.3, H.4, H.5, H.7 : 2017
Tel: 01274 752407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk Printing errors and omissions excepted INCLUDES:
2 x Design Certifcates 4 x Installation Certifcates 4 x Commissioning Certifcates 4 x Acceptance Certifcates 3 x Modification Certifcates 1 x Verification Certifcate
TIS 1814 Emergency Lighting Log Book
TIS 1814 - Emergency Lighting Log Book Tel: 01274 752407 Fax: 01274 870 175
Email: testinstruments@btinternet.com - www.testinstrumentsolutions.co.uk Printing errors and omissions excepted
TIS 1815
COMPLIES WITH BS 5266-1, BS 5266 Part 1 Clause 12.1, BSEN 50172 / bs 5266-8 BSEN 1838 : 1999 / BS 5266 : 1999, BS 5266-1 : 2016
Emergency Lighting Certificate Book
TIS 1815 - Emergency Lighting Certificate Book
Printing errors and omissions excepted
COMPLIES WITH BS 5266-1, BS 5266 Part 1 Clause 12.1, BSEN 50172 / bs 5266-8 BSEN 1838 : 1999 / BS 5266 : 1999, BS 5266-1 : 2016
Printing errors and omissions excepted
46
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
TIS 1612-500
TIS 1612/4ED
Test Date:
Re-Test Due: Amp
RATING
Test Engineer:
4th Edition Passed Labels
Tested: Re-Test: Engineer:
49mm x 25mm - Pack of 500
TIS 1616-250 Tuff Tag Passed Labels
FAILED
DO NOT USE
DANGER 230 VOLTS
Tested:
Engineer:
39mm x 25mm - Pack of 200
DANGER TIS VL110V
DANGER 400 VOLTS
TIS VL400VB
49mm x 25mm - Pack of 250
DANGER 33 kV
TIS VL33KV SAFETY ELECTRICAL CONNECTION DO NOT REMOVE
WARNING Live Connection
TIS CLLC
01274 752 407
TIS CLSEC
DANGER Live Busbars
TIS WLLB
WARNING
Fire Alarm Supply
Earth Do Not Remove
TIS CLEDR
TIS 1617-200 Plug Top Failed Labels
App ID:
BETWEEN
TIS VL230V
75mm x 23mm - Pack of 250
TIS 1615-200 Medium Failed Labels
110 VOLTS
TIS CLMS
TIS 1620-250 Passed Pat Wrap Labels
Tuff Tag Failed Labels also available at same price
49mm x 25mm - Pack of 200
Electrical Danger Labels
Amp
RATING
Test Engineer:
ELECTRICAL SAFETY TEST
Test Engineer:
Re-Test Due: FUSE
PASSED
Test Date:
23mm x 25mm - Pack of 500
ELECTRICAL SAFETY TEST
Appliance ID:
TIS 1613-200 Standard Failed Labels
Main Switch
39mm x 25mm - Pack of 500
4th Edition Tuff Tag Labels Also Available
125mm x 25mm Pack of 250
Test Date:
Plug Top Passed Labels
App ID:
49mm x 25mm - Pack of 500
Appliance ID:
TIS 1616-500
Medium Passed Labels
ELECTRICAL SAFETY TEST
Appliance ID:
FUSE
PASSED
Standard Passed Labels
TIS 1614-500
TIS WLFAS
01274 870 175
DANGER 220 VOLTS
TIS VL220V
DANGER 3.3 kV
TIS VL3300V
DANGER High Voltage
TIS VLHV
WARNING Fibre Optic Cables
TIS WLFOC
CAUTION
This installation has wiring colours to two versions of BS 7671. Great care should be taken before undertaking extension, alteration or repair that all conductors are correctly identified.
23mm x 25mm - Pack of 500
DANGER 240 VOLTS
TIS VL240V
DANGER 6.6 kV
TIS VL6600V
DANGER DIFFERENT VOLTAGES EXIST
TIS VLDVE
WARNING Automatic Start
TIS WLAS
DANGER 400 VOLTS
TIS VL400V
DANGER 11 kV
TIS VL11KV
DANGER
Isolate Before Opening
TIS WLIBO
WARNING More Than One Supply
TIS WLMTOS
DANGER 440 VOLTS
TIS VL440V
DANGER 22 kV
TIS VL22KV
WARNING Isolate Elsewhere
TIS WLIE
For Equipment Outdoors
TIS WLFEO
OTHER LABELS AVAILABLE ON REQUEST
TIS CWIR250
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
47
Solar Photovoltaic Test Equipment
PV-ISOTEST
48
Page 49
I-V500W
Pages 50/51
I-V400W
Pages 52/53
PVCHECKs
Pages 54/55
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
ORDER CODE HV0PVISO
PV-ISOTEST MULTIFUNCTION DEVICE FOR CHECKING ELECTRIC SAFETY AND PERFORMANCE OF A PHOTOVOLTAIC SYSTEM Multifunction instrument for electrical safety testing and troubleshooting of photovoltaic systems up to 1,500V DC. - Insulation measurement up to 1,500V DC even on live systems - Localization of the faulty module through the new GFL function - Continuity of the protective conductor with 200mA PV-ISOTEST represents a real innovation in the panorama of PV verification and testing instrumentation. PV-ISOTEST measures the insulation resistance of a single module, a string or even an entire photovoltaic field up to 1,500 V DC according to IEC/EN62446 standard. Traditional insulation meters would require a DC-rated switch-box to short-circuit the positive and negative terminals of the module/string/PV field under test. With PV-ISOTEST the use of any external device is not required, PV-ISOTEST carries out the measurements in full autonomy and self-sufficiency. In addition, through the new GFL (Ground Fault Locator) function, PV-ISOTEST indicates the position of any poor insulation on a string of the photovoltaic system, due, for example, to water or humidity leakage.
Functions • • • • • • • • • •
Guideline Conformity
Measurement category: CAT III 1500V DC / CAT III 1000V AC AC TRMS voltage measurement: 3 ÷ 1000V DC voltage measurement: 3 ÷ 1500V Insulation resistance: 250, 500, 1000, 1500V GFL function to locate the fault position in the string Measurement of polarization index P.I. Dielectric absorption ratio D.A.R Continuity of protective conductors with 200mA Size (LxWxH) (mm): 235 x 165 x 75mm Weight: 1.2kg
01274 752 407
01274 870 175
• • • • • • • • •
IEC/EN61010-031 IEC/EN61010-1 IEC/EN61010-2-030 IEC/EN61010-2-033 IEC/EN61010-2-034 IEC/EN61326-1 IEC/EN61557-2 IEC/EN61557-4 IEC/EN62446-1
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
49
I-V500w 1500V MULTI
1500V
STRING
128PTS
128PTS
I-V Curve Measurement MULTI
I-V1500V Curve Measurement 128PTS
› I-V Curve measurement › STRING up to 1500V and 15A* › Power measurement of modules and strings › › Open-circuit (Voc)with upPT300N to 1500V I-V Curve measurement up to 1500V and 15A* › Ambient and Panel voltage temperature probe** › Short-circuit current (Isc) up to 15A › with Solar 02 Power measurement of modules and strings › Wireless environmental measurements › Irradiance measurement with HT304N Open-circuit voltage (Voc) up to 1500V remote unit** remotelimits sensor › No distance for environmental measurements with Short-circuit current (Isc) up to 15A Irradiance measurement with HT304N Solar 02 remoteand unitPanel temperature with PT300N probe** › I-V Curve measurement up to 1500V and 15A* › Ambient remote sensor › Power measurement of modules and strings › Wireless environmental measurements with Solar 02 * 1000V/15A or 1500V/10A ** Check standard and optional accessories › Open-circuit voltage (Voc) up to 1500V remote unit** › Short-circuit current (Isc) up to 15A › No distance limits for environmental measurements with › Irradiance measurement with HT304N Solar 02 remote unit remote sensor * 1000V/15A or 1500V/10A ** Check standard and optional accessories
› › › › ›
I-V Curve Measurement
Ambie Wirele remote No dis Solar 0
* 1000V/1
MULTI
1500V
STRING
128PTS
I-V Curve Measurement › › › › ›
› Ambient and Panel temperature with PT300N probe** › Wireless environmental measurements with Solar 02 Irradiance sensor HT304N. remote unit** › No distance limits for environmental measurements with Solar 02 remote unit
I-V Curve measurement up to 1500V and 15A* Power measurement of modules and strings Open-circuit voltage (Voc) up to 1500V Short-circuit current (Isc) up to 15A Irradiance measurement with HT304N remote sensor
* 1000V/15A or 1500V/10A
Irradiance sensor HT304N.
** Check standard and optional accessories
Solar02 remote unit.
1500V
Why I-V500w? Irradiance sensor HT304N.
Solar02 remote unit.
Only one person needed to measure.
Why I-V500w? 128PTS
MULTI STRING
› 1500V & 15A: Suitable for needed new PV plants with 1500VDC str Only also one person to measure.
I-V Curve Measurement › Compact, lightweight and On-board screen: I-V500w needs
Solar02 remote unit.
returns immediate test results with OK or NOT OK outcome. › 1500V & 15A: Suitable also for new PV plants with 1500VDC string voltage. › I-V Curve measurement up to 1500V and 15A* › seconds Ambient and Panel temperature wit › Multi-String Autothanks Start: Just to measure, › Compact, lightweight and On-board screen: I-V500w needs only one person to thefew on-board screen and save dat › Power measurement of modules and strings › Wireless environmental measurem › Wi-Fi Connection: Connect your smartphone or tablet to do returns immediate test results with OK or NOT ›OKOpen-circuit outcome. voltage Why I-V500w? (Voc) up to 1500V remote unit** exclusive features Troubleshooting Assistant, Jump function a › Multi-String Auto Start: Just few seconds to measure, save current data and move to15A nextlike string. › No distance limits for environmen › Short-circuit (Isc) up to › 1500V & 15A: Suitable also for new PV plants with 1500VDC string voltage. ›› Compact, Wi-Fi Connection: Connect your smartphone or tablet to download and analyze in details your measures with › lightweight 1500V & 15A: Suitable also for new PV plants with 1500VDC string voltage. and On-board screen: I-V500w needs only one person thanks the on-board screen and › toIrradiance measurement with HT304N Solar 02 remote unit returns immediate test results with OK or NOT OK outcome. remotefunction sensor and * 1000V/15A or 1500V/10A ** Checkand standard and optio exclusive features like Troubleshooting Assistant, Jump others onlythanks on thetoAPP HTANALYSIS. › Compact, and On-board screen: I-V500w needs onlyavailable one person the on-board screen Auto Start: Just fewlightweight seconds to measure, save data and move to next string. › Multi-String › Wi-Fi Connection: Connect your smartphone or tablet to download and analyze in details your measures with returns immediate test results with OK or NOT OK outcome. exclusive features like Troubleshooting Assistant, Jump function and others available only on the APP HTANALYSIS. › Multi-String Auto Start: Just few seconds to measure, save data and move to next string. › Wi-Fi Connection: Connect your smartphone or tablet to download and analyze in details your measures with exclusive features like Troubleshooting Assistant, Jump function and others available only on the APP HTANALYSIS. Irradiance sensor HT304N.
Solar02 remote unit.
Only one person needed to measure.
Why I-V500w?
Irradiance sensor HT304N.
Solar02 remote unit.
Only one person nee
Why I-V500w? 50
01274 752 407
› 1500V & 15A: Suitable also for new PV plants with 1500VDC string voltage. › Compact, lightweight and On-board screen: I-V500w needs only one person thanks to returns immediate test results with OK or NOT OK outcome. › Multi-String Auto Start: Just few seconds to measure, save data and move to next string. Please contact your localtowholesaler for pricing 01274 870 175 › Wi-Fisales@t is-tic.co.uk Connection: Connect your smartphone or tablet download and analyze in det exclusive features like Troubleshooting Assistant, Jump function and others available only on
Multi-String Auto Start Dramatically decrease your PV String testing time with the NEW KITKELVIN. KITKELVIN provides an Auto Sequence function to HT Curve Tracers to reduce testing time up to 75%! KITKELVIN provides 2 leads for a single operator to move from string to string in a combiner box for fast testing. The Auto-sequence is Start, Acquire, Manual store, Rearm. The Start command is automatically initiated when the operator connects the probes across a string or panel, with Voc triggering the next acquisition sequence. All that you need is KITKELVIN Test Leads Accessory.
Memory and Module Database
12/07/17 15:34:26 FLD 021 022 023 024 025 026 027 028
STR 001 002 003 004 005 006 007 008
Select
MOD 134 135 136 137 138 139 140 141
No need for external storage. The Internal Memory can store up to 249 I-V Curves (128 test points) and up to 999 Quick Checks of Voc & Isc. The intuitive User Interface (UI) provides easy access to all of your stored data including I-V Curves, power curves and numerical values in the table while in use. To ease measurement set up, HT Solar instruments store up to 30 modules to ensure you have all panels in the field being tested. When you get to the field, you are ready to go for the entire day!
MEM I-V
Measurement Results (OPC & STC) The acquired I-V data or the operating conditions (OPC) is the true data acquired during I-V curve test. Taking the panel characteristics, the environmental measures (Irradiance & Temp) the instrument transforms these data points (OPC) to create the equivalent STC (Standard Test Condition) curve to evaluate if the panel or string is operating to specification. 12/07/17 15:34:26 Voc Vmpp Impp Isc Pmax FF DPmax
65.0 52.9 10.58 11.33 560 0.76 76.1
12/07/17 15:34:26
12/07/17 15:34:26
12.5 A
V V A A W
616.1 W
%
Results Select
@ STC - NO I-V
I-V Graph Select
65 V
@ STC - NO I-V
PWR Graph Select
65 V
@ STC - NO I-V
Report creation with TopView Software Measuring Solar Field is often only the beginning of your project. Customers want to see proof their fields are working as promised. HT’s Copyrighted Software, TopView makes the business of report generation a breeze. Easy download, customized naming of data fields, File storing and sharing trough HT Cloud, analyzing capabilities and display options to your preference. You can compare Strings, Combiner boxes even Farms year over year to make describing the state of the field intuitive and obvious. In addition, TopView incorporates standard templates for professional-looking reports customizable with your logo and company information.
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
51
PHOTOVOLTAIC TESTERS ORDER CODE HV00400W
CAT II 1000VDC MAX 1000VDC BETWEEN INPUTS
I-V400w
CAT III 300VAC MAX 265VAC BETWEEN INPUTS
MULTIFUNCTION DEVICE FOR MAINTENANCE AND TROUBLESHOOTING OF PHOTOVOLTAIC SYSTEMS
› Measurement of I-V Curve of a module or of a string › Measurement of open-circuit voltage and of short-circuit current Voc/Isc › Database of 30.000 selectable photovoltaic modules I-V400w allows field detection of I-V Curve an of the main characteristic parameters both of a single module and of a string for PV installations up to a maximum of 1000V and 15A. For measuring I-V Curve, I-V400w manages an internal database modules, (which can be updated at any time by the user) to compare the measured data with the rated values, thus allowing the immediate evaluation whether the string or the module fulfills the efficiency parameters declared by the manufacturer. I-V400w carries out irradiance and temperature measurement directly or under remote mode trough the optional unit SOLAR 02, synchronized with main unit I-V400w. Also for I-V400w, the display at the end of the test of I-V Curve is a clear indication about the compliance with the specifications declared by the panel manufacturer.
Functions
Main features
Maintenance of photovoltaic system • Measurement of PV module/string output voltage up to 1000V DC • Measurement of PV module/string output current up to 15A DC • 128 points per I-V Curve in STD or Capacitive mode • Measurement of Voc-Isc-Pmax-Vmpp-Impp-Fill Factor • Measurement of cell temperature through external probe • Measurement of irradiation [W/m 2] through reference cell • Measurement of DC and rated power at module/string output • Detection of I-V Curve with direct measurement of Irr/Temp parameters • Detection of I-V Curve using the remote unit SOLAR02 • Measurement of resistance of series Rs of panels • Measuring method with 4 terminals • Direct comparison with reference conditions (STC – 1000W/m 2, 25°C) • Test result OK / NO • Internal database for managing up to 30 PV modules (30.000 modules by software) • Internal memory for data saving • Recalling measured data on the display • Optical/USB interface for transferring data onto the PC • Help on line on the display
Display:
LCD custom, 128x128pxl, with backlight
Power supply:
6x1.5V alkaline batteries type AA LR06
Automatic power off:
after 5 minutes in stand-by
Duration for I-V Curve:
> 200 curves
PC interface:
opto-isolated optical / USB
Safety:
IEC/EN61010-1
Safety and measuring accessories: Measurement of I-V Curve: Insulation:
IEC/EN61010-031, IEC/EN61010-032
Pollution level:
2
Measurement category: Size:
CAT II 1000V DC, CAT III 300V (to earth) Max 1000V between inputs 235x165x75 mm
Weight (batteries included):
1.3 kg
IEC/EN60891, IEC/EN62446 double insulation
14
52
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Result of I-V Curve: OK
Measuring a I-V Curve on a string through remote synchronization of irradiation and temperature Manual insertion of a module
Detail of the single results of I-V Curve: OK
Measuring Curve IV with environmental sensors connected to I-V400w General Menu
Optional accessories
Accessories provided KITGSC4
Set of 4 cables + 4 alligator clips
PT300N
PT1000 probe for PV modules temperature
KITPVMC3
Set of 2 adapters with connectors MC3
SP-0400
Shoulder strap to use the device with free hands
KITPVMC4
Set of 2 adapters with connectors MC4
SOLAR02
Remote unit for Irradiation and Temperature
HT304N
Sensor for irradiation measurement
KITPVEXT25M
Set of 2 banana cables 4mm, Green/Black, 25m
M304
Mechanical inclinometer
TOPVIEW2006
Windows software + optical/USB C2006 cable
VA500
Rigid carrying case User Manual ISO9000 calibration certificate
01274 752 407
01274 870 175
15
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
53
PHOTOVOLTAIC TESTERS ORDER CODE HV00PVCS
PVCHECKs
CAT III 300V MAX 1000V BETWEEN INPUTS
MULTIFUNCTION DEVICE FOR COMMISSIONING TESTS OF ELECTRIC SAFETY AND PERFORMANCE OF A PHOTOVOLTAIC SYSTEM
Automatic test in a sequence of: › Measurement of insulation up to 1000VDC › Open-circuit voltage and short-circuit current Voc/Isc › Continuity of protective conductors with 200mA The multifunction device PVCHECKs allows quickly and safely carrying out the commissioning tests provided for a PV system (section in DC) and the functional test of modules/strings the system consists of according to the requirements of Standard IEC/EN62446. When testing safety, PVCHECKs is a real innovation, since it is capable of measuring insulation of a module, string or of a whole photovoltaic field (IEC/EN62446) with no need to use an external switch to short-circuit the positive and negative terminals. PVCHECKs also allows checking the functionality of the connections and of the strings in a photovoltaic field, according to the provisions of standard IEC/EN62446 by measuring the open circuit voltage and the short-circuit current at operating conditions (OPC) and referred to STC (via the optional measurement of irradiation, also with the use of optional accessories SOLAR02 and HT304N), providing an immediate result as regards the measurement just carried out, both in absolute terms and by comparison with the previously tested strings. Finally, PVCHECKs also allows analyzing the performance of the photovoltaic field (DC) under operating conditions (therefore connected to the inverter) with the use of optional accessories SOLAR02 and HT304N, providing an indication of the generated power and of the performance of the field itself.
Functions
Main features
Maintenance of photovoltaic system • Continuity of protective conductors with test current 200mA • Insulation measurement with test voltage 250,500 and 1000VDC • Open-circuit voltage (VOC) measurement up to 1000V DC • Short-circuit current (ISC) measurement up to 15A DC • DC voltage - DC current - DC power measurement • Measurement of irradiation [W/m 2] through reference cell HT304N • Environmental and photovoltaic module temperature measurement through PT300N probe • Use of compensation relationships Cells/Environment on Pdc • Measurements always compared to the values declared by the module’s manufacturer • Internal database for managing up to 30 PV modules (30.000 modules by software) • Test measurement of string operation • Mechanical inclinometer for verifying the correct inclination of sun rays • Result for every measurement OK/NO • Internal memory and USB output for PC connection • Help on line on the display Efficiency measurements of the photovoltaic system • Efficiency measurement of the photovoltaic field (DC side)
Display:
LCD, 128x128pxl, with backlight
Power supply:
6x1.5V alkaline batteries type AA LR06
Auto power off:
after 5 minutes
Internal memory:
256kBytes
PC interface:
optical/USB
Safety:
IEC/EN61010-1
Safety of accessories:
IEC/EN61010-031
Measurements:
IEC/EN 62446
Insulation:
Double insulation
Pollution level:
2
Overvoltage category:
CAT III 1000VDC (to earth) Max 1000V between inputs 235x165x75mm
Size: Weight (batteries included):
1.2kg
18
54
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Continuity test result with 200mA OK
Insulation measurement with method “whole photovoltaic field”
Continuity test result with 200mA NOT OK
Insulation measurement result at 1000V OK
Efficiency measurement of the photovoltaic field
Automatic sequence test result OK
Optional accessories
Accessories provided Standard 10-100A DC clamp, diameter 30mm
PT300N
PT1000 probe for PV modules temperature
KITGSC4
Set of 4 cables + 4 alligator clips
SOLAR02
Remote unit for Irradiation/Temperature measurement
KITPCMC3
Set of 2 adapters with connectors MC3
HT304N
Reference cell for irradiation measurement
KITPCMC4
Set of 2 adapters with connectors MC4
M304
Mechanical inclinometer
TOPVIEW2006
Windows software + optical/USB C2006 cable
SP-0400
Shoulder strap to use the device with free hands
BORSA2051
Soft carrying bag
KITPVEXT25M
Set of 2 banana cables 4mm, Green/Black, 25m
606-IECN
Connectors with magnetic terminal
HT4004
ISO9000 calibration certificate User manual and quick guide
01274 752 407
01274 870 175
19
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
55
Power Quality Analysers
56
PQA824
Pages 57/58
PQA823
Pages 57/58
VEGA78
Pages 57/58
PQA820
Pages 59/60
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
POWER QUALITY ANALYZERS ORDER CODE HV000824 | HV000823 | HV000078
PQA824|PQA823|VEGA78
CAT III 600V MAX 1000V BETWEEN INPUTS
THREE-PHASE POWER QUALITY ANALYZERS
Functions •
• • • • • • • •
• • • • • • • •
Main features
Simultaneous measurement of power parameters on single-phase and three-phase 3-wire and 4-wire systems 5 input channels for voltages and 4 input channels for currents Numerical and graphic display (waveforms) Voltage and current vector diagram Voltage and current harmonic analysis up to the 49th with THD% Recording of voltage anomalies (dips, peaks) with 10ms resolution Flicker analysis in compliance with EN50160 (only PQA823 - PQA824) Recording of fast transients (spikes) with resolution 5µs (only PQA824) Recording of motor starting currents with resolution 10ms (INRUSH) (only PQA823 - PQA824) Voltage unbalance (NEG%, ZERO%) Integration period selectable from 1s to 60min Preset and custom recordings Touchscreen colour display Power supply with rechargeable Li-ION battery Memory extension with external Compact Flash card Possibility of connecting an external pen drive PC interface with USB port
Memory extension:
TFT, 65536 colours, (320x240pxl) with high contrast, touch screen 1x3.7V rechargeable Li-ION battery, with external adapter, duration >3h, auto power of after 5 minutes’ idling 15Mbyes (duration approx. 3 months @ IP=15min and 251 selectable parameters) external Compact Flash card (ca. 32Mb)
PC interface:
USB 2.0
Safety:
IEC/EN61010-1
Insulation:
double insulation
Measurement category:
CAT IV 600V (Phase – Neutral) CAT IV 1000V (between inputs) EN50160
Display: Power supply: Internal memory:
Power quality and Flicker: Electric energy quality:
EN61000-4-30, class B
Unbalance:
EN61000-4-7, EN50160
Size:
235x165x75mm
Weight (battery included): approx 1kg
28
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
57
PQA824, PQA823 and VEGA78 are three-phase and singlephase power analyzers. They allow for the analysis of all electric parameters which can be measured nowadays, elaborating them easily and quickly. These devices can be easily programmed thanks to the new colour touchscreen display with icon menu, which guarantees the selection of internal parameters in a simple and intuitive way. The Help online function available on each screen is a valid and concrete help for the operator in understanding how the devices are used. Each internal parameter is easily reached through the typical tree structure, widely known to Windows system users. The devices allow displaying the parameters in numerical and graphic mode, both for periodical analysis and for harmonic analysis. The graphic function “vector diagram” allows, among other things, to immediately evaluate the phase angle between input voltage and current signals, thus defining the loads’ nature. The 15MB internal memory allows saving recorded data for a remarkable number of consecutive days. Model PQA824, compared to PQA823 and VEGA78, also allows detecting spikes on input voltages with a minimum resolution of 5µs (200kHz), setting different trigger thresholds which are very useful when solving typical problems on installations (monitoring atmospheric charges, commutations of switching suppliers, disturbance frequencies, etc.)
Current harmonics’ display in real time
Display of recorded power graph
Voltage and current vector diagram
Energy consumption display
Waveform display (voltage)
General Menu
Optional accessories
Accessories provided HTFLEX33E
Flex clamp 3000A, diameter 174mm, 4 pieces
HTFLEX35
Flex 3000A AC clamp, diameter 274mm
KIT800
Set of 5 cables + alligator clips
HT96U
Standard 1-100-1000A AC clamp, diameter 54mm
A0055
AC/DC battery charger power supply 230V 50/60Hz*
HT97U
Standard 10-100-1000A AC clamp, diameter 54mm
HT98U
Standard 1000A DC clamp, diameter 50mm
YABAT0003HT1
Rechargeable 3.7V Li-ION battery
HP30C2
Standard 200-2000A AC clamp, diameter 70mm
PT400
Touch-screen pen
HP30C3
Standard 3000A AC clamp, diameter 70mm
TOPVIEW2007
Windows software + USB cable
HT4005N
Standard 5-100A AC clamp, diameter 20mm
VA500
Rigid Soft carrying bag
HT903
3x1-5A/1V box for external TA connection
A0056
External power supply 110VAC-60Hz /12VDC
CF800
1GB Compact Flash Card
MCR800
Compact flash card reader
606-IECN
Connector with magnetic terminal
SP-0400
Set of straps for slinging the instrument over one’s shoulder
User manual on CD-ROM Quick user guide ISO9000 calibration certificate (*) Please check accessory line to find the correct power adapter for your country
58
01274 752 407
01274 870 175
29
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
ORDER CODE HV000820 | HV000819
PQA820
CAT IV 300V
THREE-PHASE AND SINGLE-PHASE POWER QUALITY ANALYZERS
Functions
MAX 415V BETWEEN INPUTS
Main features
•
AC TRMS voltage in single-/three-phase systems
•
AC TRMS current in single-/three-phase systems
•
Active, Reactive and Apparent Power/Energy
Power supply:
rechargeable Li-ION battery
External power supply:
100 ÷ 415V, 50/60Hz > 30 days (@ PI = 10min)
•
Cosphi and Power Factor
Recording duration
•
Voltage, Current, DC Power
Recording period:
5, 10, 30s, 1, 2, 5, 10, 15, 60min)
•
Neutral current
PC interface:
USB 2.0 and Wi-Fi
•
Voltage dips and peaks on 10ms
Safety:
IEC/EN61010-1, double insulation
•
Voltage unbalance (NEG%, ZERO%)
Mechanical protection:
IP65 (closed case)
•
Measurements using external CT and VT
Measurement category:
CAT IV 300V, max 415V between inputs
•
Voltage/current waveforms
Reference standards:
EN50160
•
Histograms of voltage/current harmonics and THD%
Operating temperature:
0 ÷ 40°C
•
Voltage/current vector diagram
Operating humidity:
<80%RH
•
Periodical recording with selectable PI
-10 ÷ 60°C
•
Maximum number of simultaneously recorded quantities 383
•
Voltage and current harmonic analysis up to the 49th
Storage temperature: Storage humidity:
Calculation and recording of voltage/current THD%
Size:
235x165x75mm
• •
Indication of recording duration
01274 752 407
01274 870 175
<80%RH
Weight (battery included): approx 0.7 kg
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
59
PQA820 is are the innovative proposal by HT to easily analyze all involved components on a three-phase or single-phase electric system. When designing them, HT has taken particular care of three aspects: setting, the operating or storage environment and data transfer. • PQA820 does not need to be set . It simply needs to be connected, started and they respectively record 383 quantities simultaneously. • They are provided with a comfortable IP65 case, which allows working in any kind of environment. • When recording has finished, thanks to the WI-Fi connection, the devices are capable of transferring all data onto a tablet, smart phone or PC. Further to the Wi-Fi connection, PQA devices are provided with USB connection for transferring data via cable to the PC through the provided TopView software. They do not need any batteries since they are auto powersupplied from the power they are analyzing. The internal battery is automatically recharged by the input voltage and will provide the necessary energy to go on recording in case power supply is interrupted.
to understand what happened in that spot and in that particular moment! PQA820 records 383 quantities which can be recalled and dragged onto the screen to be compared between each other; for example, if you are displaying the trend of voltages and you want to check for the possible presence of harmonic distortion, it will be sufficient to scroll through the list of recorded measures and drag the one relevant to harmonics to the screen. The same can be done for all other quantities: power, cosphi, current, energy, etc. Everything can then be shared on HT Cloud, the web database created by HT to archive recordings and share them quickly with anyone around the world. Through HTCLOUD™ you will be able to share all measurements with you colleagues and/or download them from any PC/Mobile device connected on the web.
To make the most of the technology used by PQA820 we recommend using the HTanalysis App (available for free download on AppStore and Google Play) on a tablet or smart phone. Here are some of the functions of HTanalysis: • Display of measured data on high-definition screen. • Possibility of “scrolling” through a determined waveform and immediately detecting its critical “moments”: it will be sufficient to “touch” a certain spot of the screen in which the measured signal is proposed to immediately obtain all necessary information in order
IP65 - Waterproof and resistant to extreme conditions.
Optional accessories
Accessories provided KITMPPACW
Set of 4 measuring cables
HT96U
AC clamp for leakage current, 1-100-1000A/1V, diameter 54mm
KITMPPACC
Set of 4 alligator clips
HT97U
Standard 10-100-1000A AC clamp, diameter 54mm
606-IECN
Adapters with magnetic terminal (4x)
HT98U
HTFLEX33L
Flex 1000A AC clamp, diameter 174mm (4x)
HP30C2
TOPVIEW2007
PC Windows software + USB cable
HP30D1
Standard DC 1000A/1V clamp, diameter 83 mm
BORSA2051
Soft carrying bag for accessories
HT903
3x1-5A/1V box for connection to external CT
Quick user guide
ACONBIN
Adapter for the connection of standard clamps
DC clamp for leakage current, 1000A/1V, diameter 50mm Standard AC 200-2000A/1V clamp, diameter 70 mm
ISO9000 calibration certificate User manual on CD-ROM
60
01274 752 407
01274 870 175
31
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Earth Resistance Test Equipment T2000|T2100 T2000|T2100 ORDER CODE HP002000 | HP002100
CAT III 150V CAT III 150V
ORDER CODE HP002000 | HP002100
CLAMP METERS FOR MEASURING EARTH RESISTANCE WITH STAKELESS TESTING METHOD AND LEAKAGE CURRENT UP TO 20A AC CLAMP METERS FOR MEASURING EARTH RESISTANCE WITH STAKELESS TESTING METHOD AND LEAKAGE CURRENT UP TO 20A AC
T2000 e T2100 are professional voltammetric clamps specially developed to evaluate resistance of earth rods with no neede to disconnect any part voltammetric of the system. The speinner T2000 T2100 are professional clamps part of the device is made of 2 jaws, one for current reading cially developed to evaluate resistance of earth rods with and the other for voltage generation. Thethe voltage jawsThe generate no need to disconnect any part of system. inner apart potential (E) on the loop during resistance (R) measurement. of the device is made of 2 jaws, one for current reading A current (I) is for consequently generated onvoltage the loopjaws andgenerate is meaand the other voltage generation. The Based on the value of parameters sured by the current jaws. a potential (E) on the loop during resistance (R) measurement.E I, the(I)instrument displays Aand current is consequently generated on the loop and is meathe resistance R value calcuBased on the value of parameters E sured by the current jaws. lated ratio. The value and I,asthetheir instrument displays measured by the device can the resistance R value calcube in case latedused as their ratio. the The single value rods do not influence measured by the deviceeach can other. T2000 also measures be used in case the single AC to 20Aeach and rodscurrent do not up influence leakage current with resoother. T2000 also measures lution 0.05mA. AC current up to 20A and This devices complywith withresostanleakage current dard IEC/EN61010-1 in lution 0.05mA. CAT III 150Vcomply and they the This devices witharestanideal solution for measuredard IEC/EN61010-1 in ments be carried CAT III to 150V and theyoutareboth the in domestic and in industrial ideal solution for measureenvironments. ments to be carried out both in domestic and in industrial environments.
Functions • • • • • • • • • • • • • • • •
Technical Specifications
Earth resistance with stakeless testing method Functions Measurement of leakage current on earth systems (only T2000) Setting of alarm thresholds on measurements Earth resistance with stakeless testing method Storage of measurement results Measurement of leakage current on earth systems (only T2000) Detection of disturbance currents on measurement Setting of alarm thresholds on measurements Data HOLD, Backlight, Auto Power OFF Storage of measurement results Maximum diameter for clamp 32mm Detection of disturbance currents on measurement Serial interface RS-232 for connection to devices of MacrotestG series (only T2100) Data HOLD, Backlight, Auto Power OFF Maximum diameter for clamp 32mm Serial interface RS-232 for connection to devices of MacrotestG series (only T2100)
Main features
Main Power supply:
Resistance measurementSpecifications Technical • Measuring range Ω: 0.010 ÷ 1000 • Resolution Ω: 0.001 ÷ 20 Resistance measurement • Basic accuracy Ω: ± (1%reading + 0.01) • Measuring range Ω: 0.010 ÷ 1000 TRMS current measurement (only T2000) • Resolution Ω: 0.001 ÷ 20 • Measuring range: 0.00mA ÷ 20A • Basic accuracy Ω: ± (1%reading + 0.01) • Resolution: 0.05mA ÷ 0.01A TRMS current measurement (only T2000) • Basic accuracy: ± (2.5%reading + 1mA) • Measuring range: 0.00mA ÷ 20A • Resolution: 0.05mA ÷ 0.01A • Basic accuracy: ± (2.5%reading + 1mA)
Accessories provided
features batteries type AA 4x1.5V
Accessories provided Resistive test loop
Memory: Power supply: Display:
99 locations batteries typedisplay AA 4x1.5V LCD 4-digit + decimal point, backlight
Memory: level: Pollution Display: Safety:
99 2 locations LCD 4-digit display + decimal point, backlight IEC/EN61010-1-2-032
Pollution level:category: 2 CAT III 150V Measurement IEC/EN61010-1-2-032 Safety: 293x90x66mm Size (LxWxH): III 150V Measurement category: CAT 1320g Weight (batteries included): 293x90x66mm Size (LxWxH): Weight (batteries 01274included): 752 407
Batteries Resistive test loop User Manual C2100 C2100
Batteries calibration certificate ISO9000 User Manualcable Hypertac / Jack 3,5mm Connection RS-232 T2100)certificate ISO9000(only calibration Rigid Carrying case Connection cable Hypertac / Jack 3,5mm RS-232 (only T2100) Rigid Carrying case
1320g
01274 870 175
81
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
61 81
Data Loggers Single & Three Phase
62
XL421
Page 63
XL422
Page 64
XL423
Page 65
XL424
Page 66
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
DATA LOGGERS ORDER CODE HV000421
ORDER CODE HV000421
XL421
CAT IV 600V
CAT IV 600V
XL421
TRMS SINGLE-PHASE CURRENT DATA LOGGER
TRMS SINGLE-PHASE CURRENT DATA LOGGER
XL421 is a Data Logger capable of measuring and recording the true root mean square(TRMS) value of AC current up to 2500A in single-phase electric systems for different applications (evaluation of load currents, rated powers of transformers, etc.). The device is enclosed in a pratical waterproof plastic case with integrated flex clamp jaws able to surround also a big-sized cable or bar. Thanks to an advanced memory management algorithm it is possible to monitor a system even for a long time. The device starts recording with a sampling period which can be selected through software among 1, 6, 30 and 60 seconds and, when memory is almost full, the previously recorded values are “re-sampled” according to the subsequent value of the sampling period, thus freeing part of the memory; the device then goes on recording new values, using the new measuring interval. In this way, it is possible to keep the device recording up to approximately 1 year. Each recording is kept stored in the internal memory and can be downloaded and managed by PC always through a dedicated software. Data Logger XL421 is also provided with a special adhesive strap which makes it possible to place it in any place in the installation where measuring is needed. The high protection rating (IP65) makes this device fully reliable also under extreme operating conditions.
XL421 is a Data Logger capable of measuring and recording the true root mean square(TRMS) value of AC current up to 2500A in single-phase electric systems for different applications (evaluation of load currents, rated powers of transformers, etc.). The device is enclosed in a pratical waterproof plastic case with integrated flex clamp jaws able to surround also a big-sized cable or bar. Thanks to an advanced memory management algorithm it is possible to monitor a system even for a long time. The device starts recording with a sampling period which can be selected through software among 1, 6, 30 and 60 seconds and, when memory is almost full, the previously recorded values are “re-sampled” according to the subsequent value of the sampling period, thus freeing part of the memory; the device then goes on recording new values, using the new measuring interval. In this way, it is possible to keep the device recording up to approximately 1 year. Each recording is kept stored in the internal memory and can be downloaded and managed by PC always through a dedicated software. Data Logger XL421 is also provided with a special adhesive strap which makes it possible to place it in any place in the installation where measuring is needed. The high protection rating (IP65) makes this device fully reliable also under extreme operating conditions.
Functions and characteristics Accessories provided • • • • • • • • • • •
• • • • • • • • • • • •
38
Accessories provided
TRMS measurement VELCROsingle-phase current Adhesive strap 50x70mm Measuring range: 1 ÷ 2500A AC TOPVIEW2004 Windows software for PC + serial cable C2004 Accuracy: ±(1.0%reading+1 digit)
VELCRO
Adhesive strap 50x70mm
TOPVIEW2004
Windows software for PC + serial cable C2004
Resolution: BORSA 20001A Soft carrying bag Operating frequency: 50±6Hz, 60±6Hz Bandwidth: 3200Hz Batteries Sampling frequency: 64User spotsManual in 20ms Integration period: 1s, 6s, 30s, 60s, 5min Memory capacity: 1Mbyte Serial interface: RS-232 Integration period...........duration in days: 1s ...........5 6s ...........34 30s .........170 Optional accessories 60s .........364(*) 5min .......1820(*) Front panel indication: LED diodes Power batteriesadapter type AA LR6 C2009 supply: 2x1.5V RS232-USB Battery life: >6months (with loaded batteries) Safety: IEC/EN 61010-1 Measurement category: CAT IV 600V (to earth) Insulation: Double insulation Pollution level: 2 Mechanical protection index: IP65 Max height: 2000m Max diameter of flex clamps: 174mm Size (LxWxH): 120x80x43 mm Weight (batteries included): approx. 0.5kg
BORSA 2000
Soft carrying bag Batteries User Manual
Optional accessories C2009
RS232-USB adapter
*according to battery duration
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
63
ORDER CODE HV000422ORDER CODE HV000422
CAT IV 600V
XL422 XL422 CAT IV 600V
TRMS THREE-PHASE TRMSCURRENT THREE-PHASE DATA LOGGER CURRENT DATA LOGGER
GER
XL422 is a Data Logger XL422 capable is a Data of measuring Logger capable and recording of measuring the and recording true root mean square(TRMS) true root mean valuesquare(TRMS) of AC current up value to 2500A of AC current up to 250 in three-phase 3-wire in three-phase electric systems 3-wire for different electric systems applications for different applicat (evaluation of load currents, (evaluation rated of load powers currents, of transformers, rated powers etc.).of transformers, e The device is enclosed Theindevice a pratical is enclosed waterproof in aplastic praticalcase waterproof with plastic case integrated flex clampintegrated jaws able flex to surround clamp jaws alsoable big-sized to surround cablesalso big-sized ca or bars. Thanks to anoradvanced bars. Thanks memory to anmanagement advanced memory algorithm management algori it is possible to monitor it isapossible system even to monitor for a long a system time. even The device for a long time. The de starts recording with starts a sampling recording period with awhich sampling can beperiod selected which can be selec through software among through 1, 6, software 30 andamong 60 seconds 1, 6, 30and, andwhen 60 seconds and, w memory is almost full, memory the previously is almost recorded full, the previously values arerecorded “revalues are sampled” according sampled” to the subsequent according value to theofsubsequent the sampling value of the samp period, thus freeing part period, of the thusmemory; freeing part the device of the memory; then goesthe on device then goes recording new values,recording using thenew newvalues, measuring usinginterval. the newInmeasuring this way, interval. In this w it is possible to keepit the is possible device recording to keep the up device to approximately recording up to approxima 90 days. 90 days. Each recording is kept Eachstored recording in theis internal kept stored memory in the andinternal can memory and be downloaded and be displayed downloaded on and the PC displayed always through on the aPC always throug dedicated software. dedicated Data Logger software. XL422Data is also Logger provided XL422 withis also provided a special adhesive strap a special whichadhesive makes itstrap possible whichtomakes place it possible in to place any place in the installation any place where in the measuring installation is needed. where measuring The high is needed. The h protection rating (IP65) protection makes rating this device (IP65)fully makes reliable thisalso device under fully reliable also un extreme operating conditions. extreme operating conditions.
Functions and Functions characteristics and characteristics • • • • • • • • • • •
• • • • • • • • • • • •
TRMS three-phase• current TRMS measurement three-phase current measurement Measuring range: •1 ÷Measuring 2500A AC range: 1 ÷ 2500A AC Accuracy: ±(1.0%reading+1 • Accuracy:digit) ±(1.0%reading+1 digit) Resolution: 1A • Resolution: 1A Operating frequency: • Operating 50±6Hz, frequency: 60±6Hz 50±6Hz, 60±6Hz Bandwidth: 3200Hz • Bandwidth: 3200Hz Sampling frequency: • Sampling 64 spots in frequency: 20ms 64 spots in 20ms Integration period:• 1s,Integration 6s, 30s, 60s, period: 5min 1s, 6s, 30s, 60s, 5min Memory capacity:•1Mbyte Memory capacity: 1Mbyte Serial interface: RS-232 • Serial interface: RS-232 Integration period...........duration • Integration period...........duration in days: in days: 1s ...........1.5 1s ...........1.5 6s ...........8 6s ...........8 30s .........42 30s .........42 60s .........91 60s .........91 5min .......455(*) 5min .......455(*) Front panel indication: • Front LED panel diodes indication: LED diodes Power supply: 2x1.5V • Power batteries supply: type 2x1.5V AA LR6 batteries type AA LR6 Battery life: >6months • Battery (with life: loaded >6months batteries) (with loaded batteries) Safety: IEC/EN 61010-1 • Safety: IEC/EN 61010-1 Measurement category: • Measurement CAT IV 600V category: (to earth) CAT IV 600V (to earth) Insulation: Double • insulation Insulation: Double insulation Pollution level: 2• Pollution level: 2 Mechanical protection • Mechanical index: IP65 protection index: IP65 Max height: 2000m • Max height: 2000m Max diameter of• flex Max clamps: diameter 174mm of flex clamps: 174mm Size (LxWxH): 120x80x43 • Size (LxWxH): mm 120x80x43 mm Weight (batteries• included): Weight (batteries approx. 0.5kg included): approx. 0.5kg *according to battery duration *according to battery duration
64
01274 752 407
01274 870 175
AccessoriesAccessories provided provided
VELCRO
VELCRO Adhesive strap 50x70mm Adhesive strap 50x70mm
TOPVIEW2004
TOPVIEW2004 Windows software forWindows PC + serial software cable for C2004 PC + serial cab
BORSA75
BORSA75 Soft carrying bag
Soft carrying bag
Batteries
Batteries
User Manual
User Manual
Optional accessories Optional accessories C2009
C2009 RS232-USB adapter RS232-USB adapter
39
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
DATA LOGGERS ORDER CODE HV000423
CAT IV 600V
XL423 TRMS SINGLE-PHASE VOLTAGE DATA LOGGER XL423 is a Data Logger capable of measuring and recording the true root mean square (TRMS) value of AC voltage up to 600V in single-phase electric systems for different applications (evaluation of power voltage, load unbalance, etc.). The device is enclosed in a pratical waterproof plastic case with integrated flex clamp jaws able to surround also a big-sized cable or bar. Thanks to an advanced memory management algorithm it is possible to monitor a system even for a long time. The device starts recording with a sampling period which can be selected through software among 1, 6, 30 and 60 seconds and, when memory is almost full, the previously recorded values are “resampled” according to the subsequent value of the sampling period, thus freeing part of the memory; the device then goes on recording new values, using the new measuring interval. In this way, it is possible to keep the device recording up to approximately 1 year. Each recording is kept stored in the internal memory and can be downloaded and displayed on the PC always through a dedicated software. Data Logger XL423 is also provided with a special adhesive strap which makes it possible to place it in any place in the installation where measuring is needed. The high protection rating (IP65) makes this device fully reliable also under extreme operating conditions.
Functions and characteristics • • • • • • • • • • •
• • • • • • • • • • •
TRMS single-phase voltage measurement Measuring range: 0 ÷ 600VAC Accuracy: ±(1.0%reading+1 digit) Resolution: 0.1V Operating frequency: 50±6Hz, 60±6Hz Bandwidth: 3200Hz Sampling frequency: 64 spots in 20ms Integration period: 1s, 6s, 30s, 60s, 5min Memory capacity: 1Mbyte Serial interface: RS-232 Integration period...........duration in days: 1s ...........5 6s ...........34 30s .........170 60s .........364(*) 5min .......1820(*) Front panel indication: LED diodes Power supply: 2x1.5V batteries type AA LR6 Battery life: >6months (with loaded batteries) Safety: IEC/EN 61010-1 Measurement category: CAT IV 600V (to earth) Insulation: Double insulation Pollution level: 2 Mechanical protection index: IP65 Max height: 2000m Size (LxWxH): 120x80x43 mm Weight (batteries included): approx. 0.5kg
Accessories provided KITXL423C
Set of 2 alligator clips
VELCRO
Adhesive strap 50x70mm
TOPVIEW2004
Windows software for PC + serial cable C2004
BORSA2000
Soft carrying bag Batteries and user manual
Optional accessories C2009
RS232-USB adapter
606-IECN
Connector with magnetic terminal
*according to battery duration
40
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
65
ORDER CODE HV000424
CAT IV 600V
XL424
TRMS THREE-PHASE VOLTAGE DATA LOGGER XL424 is a Data Logger capable of measuring and recording the true root mean square(TRMS) value of AC voltage up to 600V in three-phase 3-wire electric systems for different applications (evaluation of power voltage, load unbalance, etc.). The device is enclosed in a pratical waterproof plastic case with integrated flex clamp jaws able to surround also a big-sized cable or bar. Thanks to an advanced memory management algorithm it is possible to monitor a system even for a long time. The device starts recording with a sampling period which can be selected through software among 1, 6, 30 and 60 seconds and, when memory is almost full, the previously recorded values are “resampled” according to the subsequent value of the sampling period, thus freeing part of the memory; the device then goes on recording new values, using the new measuring interval. In this way, it is possible to keep the device recording up to approximately 90 days. Each recording is kept stored in the internal memory and can be downloaded and displayed on the PC always through a dedicated software. Data Logger XL424 is also provided with a special adhesive strap which makes it possible to place it in any place in the installation where measuring is needed. The high protection rating (IP65) makes this device fully reliable also under extreme operating conditions.
Functions and characteristics • • • • • • • • • • •
• • • • • • • • • • •
AC TRMS three-phase voltage measurement Measuring range: 0 ÷ 600VAC Accuracy: ±(1.0%reading+1 digit) Resolution: 0.1V Operating frequency: 50±6Hz, 60±6Hz Bandwidth: 3200Hz Sampling frequency: 64 spots in 20ms Integration period: 1s, 6s, 30s, 60s, 5min Memory capacity: 1Mbyte Serial interface: RS-232 Integration period...........duration in days: 1s ...........1.5 6s ...........8 30s .........42 60s .........91 5min .......455(*) Front panel indication: LED diodes Power supply: 2x1.5V batteries type AA LR6 Battery life: >6months (with loaded batteries) Safety: IEC/EN 61010-1 Measurement category: CAT IV 600V (to earth) Insulation: Double insulation Pollution level: 2 Mechanical protection index: IP65 Max height: 2000m Size (LxWxH): 120x80x43 mm Weight (batteries included): approx. 0.5kg
Accessories provided KITXL424C
Set of 4 alligator clips
VELCRO
Adhesive strap 50x70mm
TOPVIEW2004
Windows software for PC + serial cable C2004
BORSA2000
Soft carrying bag Batteries and user manual
Optional accessories C2009
RS232-USB adapter
606-IECN
Connector with magnetic terminal
*according to battery duration
66
41
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Power Harmonic Clamp Meters HT9023
Page 68
HT9020
Page 69
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
67
ORDER CODE HP009023
CAT IV 600V CAT III 1000V
DYNAMIC INRUSH HT9020
Functions • • • • • • • • • •
• • • • •
• • • • • • •
68
PROFESSIONAL CLAMP METERS WITH POWER/HARMONIC MEASUREMENT AND BLUETOOTH CONNECTION Power clamp meter HT9023 has been designed for measuring DC, AC+DC TRMS current up to 1000A to obtain CAT IV 600V in compliance with standard IEC/EN61010-1. They also measure Active, Reactive and Apparent Power, Energy, voltage/current harmonic analysis up to the 25th with THD% calculation in balanced single-phase or three-phase systems. They also allow testing phase sequence and concordance with the 1-terminal measuring method. It is also possible to detect the events linked to motor starting (INRUSH) currents. HT9023, also allows recording each measured electric parameter over time, with the possibility of transferring data via Bluetooth to Android devices through the HTAnalysis App or onto PC through the TOPVIEW software. The clamps are provided with a wide graphic dot-matrix screen (128x128pxl) with backlight, in order to allow reading data even in poorly lit environments. Auto power off function preserves internal battery.
Main features
DC, AC + DC TRMS current up to 1000A DC, AC + DC TRMS voltage up to 1000A Frequency with test leads and clamp jaws Phase sequence / phase concordance Resistance and Continuity test Measurement/recording of DC power and energy Active, reactive, apparent power meas./rec. on single-phase systems Active, reactive, apparent energy meas./rec. on single-phase systems Power factor measurement/recording on single-phase systems Voltage/current harmonic meas./rec. up to the 25th and THD% Measurement of DC power and energy Active, reactive, apparent power measurement on single-phase systems Active, reactive, apparent energy measurement on single-phase systems Power factor measurement on single-phase systems Voltage/current harmonic measurement up to the 25th and THD% Motor starting (INRUSH) current detection Data logger function with programmable PI Autorange Backlight Auto Power OFF Data HOLD, MAX/MIN/CREST Bluetooth for connection to PC and Android devices
01274 752 407
HT9023
01274 870 175
Display: Power supply: Duration: Internal memory: PC interface: Safety: Insulation: Pollution level: Measurement category: Max diameter of cable: Size (LxWxH): Weight (batteries included):
dot-matrix 128x128pxl with backlight 2x1.5V batteries type AAA > 50 hours 2MBytes (approx. 2 days @ IP=15min and 60 parameters) Bluetooth IEC/EN61010-1 Double insulation 2 CAT IV 600V to earth, max 1000V between inputs 45mm 252x88x44mm 0.42kg
Accessories provided YAAMK0000HT0 YAAMK0001HT0 TOPVIEWS YABRS0000NN0
Pair of test leads Pair of alligator clips Windows software for PC connection Bluetooth/USB adapter for PC connection Soft carrying bag Batteries User manual on CD-ROM ISO9000 calibration certificate Quick user guide
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
ORDER ORDER CODE CODE HP009020 HP009020
CAT CAT IV IV 600V 600V CAT CAT III III 1000V 1000V
DYNAMIC DYNAMIC INRUSH INRUSH
Functions Functions • • • • • • • • • • • • • •
HT9020 HT9020 PROFESSIONAL PROFESSIONAL CLAMP CLAMP METERS METERS WITHWITH POWER/HARMONIC POWER/HARMONIC ANDAND INRUSH INRUSH MEASUREMENT MEASUREMENT
HT9020 HT9020 have have been been designed designed for measuring for measuring DC, AC+DC DC, AC+DC TRMS TRMS current current up up to 1000A to 1000A to obtain to obtain CAT IV CAT 600V IV 600V in compliance in compliance with withstandard standard IEC/EN61010-1. IEC/EN61010-1. It also It also measures measures Active,Active, Reactive Reactive andand Apparent Apparent Power, Power, Energy, Energy, voltage/current voltage/current with THD% calculation calculation harmonic harmonic analysis analysis up to upthe to 25 theth with 25 th THD% in insingle-phase single-phase or balanced or balanced three-phase three-phase systems. systems. It allows It allows testing testing phase phase sequence sequence and and concordance concordance with the with 1-terminal the 1-terminal measuring measuring method. method. It is Italso is also possible possible to detect to detect the events the events linked linkedto to motor motor starting starting (INRUSH) (INRUSH) currents. currents. HT9020 HT9020 is is provided provided withwith a wide a wide graphic graphic dot-matrix dot-matrix screenscreen (128x128pxl) (128x128pxl) with withbacklight, backlight, in order in order to allow to allow reading reading data even data ineven poorly in poorly lit litenvironments. environments. AutoAuto power power off function off function preserves preserves internalinternal battery. battery.
Main Main features features
DC,• AC DC,+AC DC+TRMS DC TRMS current current up up to 1000A to 1000A DC,• AC DC,+AC DC+TRMS DC TRMS voltage voltage up up to 1000V to 1000V Frequency • Frequency with with test test leads leads andand clamp clamp jaws jaws Phase • Phase sequence sequence / phase / phase concordance concordance Resistance • Resistance and Continuity and Continuity testtest Measurement • Measurement of DC of power DC power andand energy energy Active, • Active, reactive, reactive, apparent apparent power power measurement measurement ononsingle-phase single-phasesystems systems Power • Power factorfactor measurement measurement on on single-phase single-phasesystems systems Voltage/current • Voltage/current harmonic harmonic measurement measurement upuptotothe the25 25ththand and THD% THD% Motor • Motor starting starting (INRUSH) (INRUSH) current current detection detection Autorange • Autorange Backlight • Backlight Auto • Power Auto Power OFF OFF Data • HOLD, Data HOLD, MAX/MIN/CREST MAX/MIN/CREST
Display: Display: Power Power supply: supply: Duration: Duration: Safety: Safety: Insulation: Insulation: Pollution Pollution level: level: Measurement Measurement category: category:
dot-matrix dot-matrix 128x128pxl 128x128pxl with backlight with backlight 2x1.5V 2x1.5V batteries batteries type AAA type AAA > 50>hours 50 hours IEC/EN61010-1 IEC/EN61010-1 Double Double insulation insulation 2 2 CAT IVCAT 600V IV 600V to earth, to earth, max 1000V max 1000V between between inputs inputs Max Max diameter diameter of cable: of cable: 45mm45mm Size Size (LxWxH): (LxWxH): 252x88x44mm 252x88x44mm Weight Weight (batteries (batteries included): included): 0.42kg 0.42kg
Included Included accessories accessories Pair testofleads test leads YAAMK0000HT0 YAAMK0000HT0 Pair of Pair alligator of alligator clips clips YAAMK0001HT0 YAAMK0001HT0 Pair of carrying carrying bag bag YABRS0000NN0 YABRS0000NN0 Soft Soft Batteries Batteries User User manual manual on CD-ROM on CD-ROM ISO9000 ISO9000 calibration calibration certificate certificate QuickQuick user guide user guide
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
117
69
117
INFRARED INFRARED THERMAL THERMAL CAMERAS CAMERAS INFRARED THERMAL CAMERAS
THT70
384 384xx288 288
ORDER ORDER CODE CODEHN000070 HN000070| HN000600 | HN000600
THT70|THT60 THT70|THT60 THT70|THT60 160 120
pp i i xx ee l
384 x 288 ORDER CODE HN000070 | HN000600 i x e l 160 160xpx120 120 ADVANCED ADVANCEDINFRARED INFRAREDTHERMAL THERMAL CAMERA CAMERA WITH WITH TOUCH TOUCH SCREEN SCREEN THT60
pp i i xx ee p
i
l
x x
WITH WITH RESOLUTION RESOLUTION384x288pxl 384x288pxl (THT70) (THT70) AND AND 160x120pxl 160x120pxl (THT60) (THT60) ADVANCED INFRARED THERMAL CAMERA WITH TOUCH SCREEN e THT70 l THT70 andTHT60 THT60are areprofessional professional thermal cameras provided IR sensor with high and thermal cameras provided with with an IRan sensor with high WITH RESOLUTION 384x288pxl (THT70) AND 160x120pxl (THT60)
resolution 384x288pxl 384x288pxl(THT70) (THT70) and 160x120 (THT60) suitable resolution and 160x120 (THT60) whichwhich makemake them them suitable both for forTHT70 useininindustrial industrial environments in the construction sector, thus allowing both use andand in the construction sector, thus and THT60environments are professional thermal cameras provided with anallowing IR sensor with high them totoresolution beused usedforfor384x288pxl energetic certification tests. peculiarity iswhich their internal iconsuitable them be energetic certification TheirTheir peculiarity is their internal iconthem (THT70) tests. and 160x120 (THT60) make structure with acapacitive capacitive colour touch-screen brightness. structure colour touch-screen withwith high high brightness. bothwith for ause in industrial environments anddisplay in display the construction sector, thus allowing possible save thermal visual images in tests. standard format the internal It isis possible totobe save thermal andand visual images in standard JPG format in theisininternal them to used for energetic certification TheirJPG peculiarity their internal icon memory onthe thewith appropriate Micro-SD and transfer thethrough PC through memory ororon appropriate Micro-SD cardcard and transfer datadata ontoonto thewith PC structure a capacitive colour touch-screen display high brightness the USB USB cansave used record IR videos. THT70 and THT60 have ain wide the It Itcan bebeused to to record videos. THT70 and THT60 haveformat a wide It interface. isinterface. possible to thermal and IRvisual images in standard JPG the interna temperature range (max. 400°C) thanks to which is possible to data carry out advanced temperature range 400°C) thanks to which it is itpossible to carry out advanced memory or on(max. the appropriate Micro-SD card and transfer onto the PC through analyses including spots,lines, isotherm lines on every image. Thermal analyses spots, andand on every image. Thermal theincluding USB interface. It lines, can areas beareas used toisotherm record IRlines videos. THT70 and THT60 have a wide cameras arethe theideal idealsolution solution detecting electric problems, checking mechanical cameras are forfor detecting problems, mechanical temperature range (max. 400°C)electric thanks to which it checking is possible to carry out advanced parts, analyses analyzingincluding hydraulic systems, forced ventilation, etc. camerasTherma parts, analyzing hydraulic systems, ventilation, Thermal cameras spots, lines, forced areas and isothermetc. lines onThermal every image. are completed completed andmade made particularly by the possibility ofchecking using optional are particularly by electric the possibility of using optional camerasand are the ideal solution performing forperforming detecting problems, mechanica interchangeable optics,the theFlash Flash LED laser pointer. Inetc. order to make interchangeable optics, LED andand the the laser pointer. In order to Thermal make parts, analyzing hydraulic systems, forced ventilation, cameras thermographic analysesmore more immediate, these thermal cameras been provided thermographic analyses immediate, these thermal cameras been provided are completed and made particularly performing byhave thehave possibility of with usingwith optiona the technology technology PictureininPicture Picture (possibility ofLED overlapping thermographic visual the Picture (possibility of overlapping thermographic and visual interchangeable optics, the Flash and the laser pointer. Inand order to make images), with the SPAN function (creation of a temperature range of interest) and with images), with the SPAN function (creation of a temperature range of interest) and thermographic analyses more immediate, these thermal cameras have been provided with the thethe automatic setting with a preset table of materials. with visua with automatic setting ofof emissivity a preset of materials. Finally,Finally, with and technology Picture inemissivity Picturewith (possibility oftable overlapping thermographic the provided provided software THTLink is possible to analyze IR photos, change colour and the software THTLink it isit possible to analyze photos, change colour images), with the SPAN function (creation of a IR temperature range of interest) palettes, prepare advancedreports reports much more. palettes, advanced and much more. withprepare the automatic setting ofand emissivity with a preset table of materials. Finally, with the provided software THTLink it is possible to analyze IR photos, change colour palettes, prepare advanced reports and much more.
THT70 384x288pxl THT70 384x288pxl THT70 384x288pxl
Functions Functionsand andcharacteristics characteristics THT60 THT70 THT60 Functions andTHT70 characteristics
THT70 THT60 THT60 THT70 Datasaving saving Data Standardformat formatof of saved images Standard saved images JPEGJPEG THT70 JPEGJPEG THT60 THT70 160x120pxl THT60 384x288pxl 384x288pxl 160x120pxl IR sensor resolution IR sensor resolution 25µm 25µm 25µm SavingofData ofIRIRvideos videos MPEG4 format • Saving in in MPEG4 format • • • saving Characteristics of IR image Voice and text annotation • • JPEG Voice and text annotation • • Temperature range -20°C a 400°C Temperature range -20°C a 400°C Standard format of saved images JPEG 384x288pxl 160x120pxl IR sensor resolution Additional characteristics Additional characteristics 25µm 25µm Saving of IR videos in MPEG4 format • • Thermal sensitivity <<0,06° 30°C Thermal sensitivity 0,06°@@30°C 30°C <<0,08° 0,08° @ 30°C Capacitive touch-screen colour display • • Capacitive touch-screen colour display • • Voice and text annotation • • Temperature range -20°C a 400°C NETD <<60mK < NETD 60mK < 80mK Power supply with rechargeable battery • • Power supply with rechargeable battery • • Additional characteristics Thermal sensitivity <••0,06° @ 30°C <• 0,08° @ 30°C Spectrum range 8÷14µm Spectrum range 8÷14µm USBinterface interface • USB to toPCPC Capacitive touch-screen colour display • • • • • NETD < 60mK 3.33mrad < 80mK IFOVIFOV (@1m) 1.14mrad (@1m) 1.14mrad 3.33mrad PAL/NTSC video output • PAL/NTSC video output Power supply with rechargeable battery • • • • • 8÷14µm • • TypeType ofSpectrum sensor IRrange UFPA •• • of sensor IR UFPA USB interface to PC • • IFOV50Hz (@1m) Frequency ••1.14mrad • 3.33mrad Frequency 50Hz PAL/NTSC video output • • Included accessories Included accessories Type of sensor UFPA • Characteristics of of IRIRIR and integrated Characteristics and integratedoptics optics • Optics 22mm f/1.0 (THT70) Optics 7,5 f/1.0 mm f/1.0 (THT60) Optics 22mm f/1.0 (THT70) Optics 7,5 mm (THT60) Frequency 50Hz • • 24.6° 29.8° 22.6° 24.6°x x18.6° 18.6° 29.8° x 22.6° Included Micro Card Micro SDSD Card 4GB4GB accessories FieldField of view (FOV) of view (FOV) (lens 22mm) (lens 7.5mm) (lens 22mm) (lens 7.5mm) Characteristics of IR and integrated optics Rechargeable Li-ION battery Rechargeable Li-ION battery (2x) (2x) BAT7X BAT7X Optics 22mm f/1.0 (THT70) Optics 7,5 mm f/1.0 (THT60) FocalFocal length of standard lens 22mm 7.5mm length of standard lens 22mm 7.5mm USB cable connection and Video USB cable for for PC PC connection and Video cablecable 24.6° x 18.6° 29.8° x 22.6° Micro SD Card 4GB Field of view (FOV) 22mm) Manual focusing of IR •(lens •(lens 7.5mm) A007X Manual focusing of optics IR optics • AC/DC power supply +Li-ION universal power supply + universal plugsplugs A007X BAT7X AC/DC Rechargeable battery (2x) Headset with microphone Headset with microphone Focal length of standard lens 22mm 7.5mm Integrated photo-camera resolution 640x480pxl Integrated photo-camera resolution 640x480pxl USB cable for PC connection and Video cable User manual onpower CD-ROM + Quick guide for use manual on CD-ROM + Quick for use Manual focusing of IR optics • • AC/DC supply +guide universal plugs A007XUser Functions Functions Rigid Carrying Rigid Carrying casecase VA6070 VA6070 Headset with microphone Integrated photo-camera resolution •• 640x480pxl Fusion PiP PiP function • Fusion function Recharging base Recharging base BRC7X BRC7X User manual on CD-ROM + Quick guide for use Adapter for tripod Adapter for tripod TRIPO7X TRIPO7X Functions 3 cursors: Central, Min, Max. •• • 3 cursors: Central, Min, Max. Rigid Carrying case VA6070SunSun screen screen SSHIELD7X SSHIELD7X Fusion PiP function • • Recharging BRC7XWindows Advanced analysis Advanced analysis Windows software base software THTLink THTLink •• • Adapter for tripod (Line,(Line, Areas, Spots) Areas, Spots) TRIPO7X 3 cursors: Central, Min, Max. • • ISO9000 calibration certificate ISO9000 calibration certificate Sun screen SSHIELD7X Correction functions Correction functions Advanced analysis • • • Windows software THTLink • • (%RH,Distance) (%RH,Distance) (Line, Areas, Spots) ISO9000 calibration certificate Availabe palettes 8 standard + 10 custom Availabe palettes 8 standard + 10 custom Correction functions Optional accessories Optional accessories • • Integrated table withwith emissivity Integrated table emissivity (%RH,Distance) • • • values of common materials values of common materials Availabe palettes 8 standard + 10 custom Optional optics 11mm (THT70) optics 11mm (THT70) RL-11-70 Optional RL-11-70 Optional accessories Alarm thresholds •• • Alarm thresholds Integrated table with emissivity Optional optics 38mm (THT70) Optional optics 38mm (THT70) • • RL-38-70 RL-38-70 values of °C, common Readings in °C, °F, °F, °K °K materials •• • Readings in Optional optics 11mm (THT60) Optional optics 11mm (THT60) RL-11-60 RL-11-60 Optional optics 11mm (THT70) RL-11-70 thresholds • • ClassClass 2Alarm laser pointer •• • 2 laser pointer Optional optics 22mm Optional optics 22mm (THT60) RL-22-60 RL-22-60 Optional optics (THT60) 38mm (THT70) RL-38-70 Readings in °C, °F, °K • • Optional optics 33mm (THT60) Optional optics 33mm (THT60) Integrated white light illuminator •• • Integrated white light illuminator RL-33-60 RL-33-60 Optional optics 11mm (THT60) RL-11-60 Class 2 laser pointer • • Optional optics 22mm (THT60) 142142 RL-22-60 Optional optics 33mm (THT60) Integrated white light illuminator • • RL-33-60 Characteristics of of IR IR image Characteristics image
70 142
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
INFRARED THERMAL CAMERAS CODE HN000070 | HN000600 CODE HN000046 384 x 288 ORDERORDER p 160 i x x e 120 l
p
i
x
e
l
160 x 120 p
i
x
e
l
THT70|THT60 THT46 ADVANCED INFRARED THERMAL CAMERA COMPACT INFRARED THERMAL CAMERAWITH TOUCH SCREEN WITHWITH RESOLUTION (THT70) AND 160x120pxl (THT60) FUNCTION384x288pxl PiP THT70THT46 and THT60 thermal cameras is are an professional absolute innovation in theprovided sector with of an IR sensor with high resolution 384x288pxl (THT70) 160x120 (THT60) which them suitable thermal cameras, both for theand advanced performance typicalmake of a highboth for usethermal in industrial and in thesize. construction sector, thus allowing level cameraenvironments and for it’s reduced them to be used for energetic certification tests. Their peculiarity is their internal icon structure withwhich a capacitive colour touch-screen with high brightness. THT46, a resolution of 160x120pxl , hasdisplay an advanced It is possible to save thermal anda visual in standard JPG format in the internal performance which allows betterimages definition of the infrared image memory or are on the appropriate card display and transfer databrightness onto the PC through They provided with anMicro-SD LCD colour with high the USB It can bemenu used very to record THT70 andforTHT60 have a wide easyIRtovideos. use, which allow a andinterface. by a drop-down temperature range (max. 400°C) thanks to which it is possible to carry out advanced simple programming by means of a keypad. analyses spots, lines, areas isotherm lines on The including temperature range is very wideand (-20°C at 350°C) andevery it is image. Thermal cameras are thetoideal for detecting problems, mechanical possible savesolution both thermal imageselectric and visual imageschecking in a standard parts,JPG analyzing Thermal format onhydraulic a micro systems, SD card. ITforced is alsoventilation, possible to etc. transfer data cameras are completed made particularly by isthealso possibility using onto the and PC via USB. Recordingperforming of IR videos available.ofTHT 46 optional interchangeable thefor Flash LED and the laser pointer. In order to make is the idealoptics, partner detecting electric problems, checking thermographic analyses immediate, these thermal cameras have been mechanical parts, more analyzing hydraulic systems, forced ventilation, etc. provided with the technology Picture in Picture (possibility of overlapping thermographic and visual This thermal camera is completed by the SPAN function images), with the functionrange (creation of a temperature range of interest) and (creation of aSPAN temperature of interest) and the automatic with the automatic setting ofwith emissivity table of materials. Finally, with setting of emissivity a preset with tablea ofpreset materials. the provided software THTLink it is possible to analyze IR photos, change colour palettes, prepare advanced reports and much more.
160x120pxl THT70 384x288pxl
Functions and Functions and characteristics characteristics
FRARED HERMAL Characteristics of IR image AMERAS IR image features
THT70
THT70 THT60 Data savingfeatures Additional Standard format of saved images JPEG JPEG 160x120pxl ORDER CODE HN000070 | HN000600 IR sensor resolution 160x120pxl/25µm384x288pxl • Powering with rechargeable battery IR• sensor resolution x 25µm 25µm Saving of IR videos in MPEG4 format • • • Temperature range -20°C a 350°Cp • USB port for PC connection i x e l Voice and text annotation • • Temperature range -20°C a 400°C • Thermal sensitivity < 0,1° @ 30°C • HDMI output Additional characteristics Thermal sensitivity < 0,06° @ 30°C < 0,08° @ 30°C • NETD: < 100mK Capacitive touch-screen colour display • • x NETD < 60mK < 80mK INFRARED ADVANCED THERMAL WITH TOUCH SCREEN Power supply withCAMERA rechargeable battery • • p i x e l • Spectral range 8÷14µm Spectrum range 8÷14µm • WITH •RESOLUTION 384x288pxl AND 160x120pxl (THT60) USB interface to(THT70) PC • • • IFOV (@1m) 2.78mrad IFOV (@1m) 1.14mrad 3.33mrad PAL/NTSC video output • • THT70•and THT60 are professional thermal cameras provided with an IR sensor with high • Sensor type IR UFPA Type of sensor IR UFPA • resolution 384x288pxl (THT70) and 160x120 (THT60) which make them suitable • Frequency 50Hz Frequency 50Hz • • Included both for use in industrial environments and in the accessories construction sector, thus allowing IR and integrated features Characteristics of optical IR and system integrated optics them to be used for energetic certification tests. Their is their7,5internal icon Optics 22mm f/1.0peculiarity (THT70) Optics mm f/1.0 (THT60) • Field of view 25° x 19° 24.6° x 18.6° 29.8° x 22.6° Micro SD Card 4GB structure with a capacitive colour touch-screen display with high brightness. Field of view (FOV) (lens 22mm) (lens 7.5mm) Li-ION battery • Standard lens focal length 9 mm BAT7Xand visualRechargeable It is 7.5mm possible to save thermal images in standard JPG(2x) format in the internal Focal length of standard lens 22mm USB cable for PC connection Video • Manual IR optical system focus memory or on the appropriate Micro-SD card and transfer dataand onto thecable PC through Manual focusing of IR optics • • AC/DC power supply + universal plugs A007X the USB interface. It can be used to record IR videos. THT70 and THT60 have a wide Functions Headset withaccessories microphone Integrated photo-camera resolution 640x480pxl Included temperature range (max. 400°C) thanks to which it is possible to carry out advanced • PiP Fusion function to mix thermal User manual on CD-ROM + Quick guide for use Functions images with visual images analyses including spots, lines, areasRigid and Carrying isotherm caselines on every image. Thermal VA6070 • 3 cursors: Central, Min, Max. Fusion PiP function • • are the ideal solution Recharging base Micro SD Card 8GB cameras electric problems, checking mechanical BRC7Xfor detecting Adapter for tripod TRIPO7X parts, analyzing hydraulic systems, forced ventilation, 3•cursors: Central, Min, Max. • • Reflected temperature correction BAT45N Rechargeable Li-ION batteryetc. Thermal cameras Sun screen SSHIELD7X are completed and made particularly performing by the possibility of using optional Advanced analysis • 4 color palettes Windows THTLink USB cablesoftware for PC connection • • (Line, Areas, Spots) interchangeable optics, the Flash LED and the laser pointer. In order to make • Integrated emissivity table of ISO9000 calibration certificate HDMI Video Cablecameras have been provided with Correction functions thermographic analyses more immediate, these thermal common materials • • (%RH,Distance) Universal Mini USB adapter + AC/DC plugand visual the technology Picture inA0045U Picture (possibility of overlapping thermographic • Readout in °C, °F, °K Availabe palettes 8 standard + 10 custom with the SPAN function (creation of a temperature range of interest) and images), Optional accessories Headset with microphone • Laser pointer Class 2 Integrated table with emissivity with the• automatic setting of emissivity with a preset table of materials. Finally, with • User manual on CD-ROM + quick guide • Built-in white light lamp values of common materials the provided software RL-11-70 THTLink it is possible to analyze IR photos, change colour Optional optics 11mm (THT70) Alarm • • Data thresholds saving B45 reports and Soft bag more. for transport palettes, prepare advanced much Optional optics 38mm (THT70) RL-38-70 384x288pxl Readings °C, °F, °K • • • Imagesinsaved in standard JPEG format THTLink Windows software Optional optics 11mm (THT60) RL-11-60 Class 2 laser • • Saving IR pointer video and audio in MPEG4 format• Optional optics 22mm (THT60) RL-22-60 Calibration certificate ISO9000 Optional optics 33mm (THT60) Integrated white light illuminator • • RL-33-60
384 288
160 120
HT70
THT60
THT70|THT60
142
Functions 01274 870 175 01274 752and 407 characteristics
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
71
COD.COD. METEL METEL HN000033 HN000033
80 80xx80 80
pp i i x x e e l l
THT33 THT33 INFRARED INFRARED THERMAL THERMAL CAMERA CAMERA WITH WITH RESOLUTION RESOLUTION 80x8080x80 AND BLUETOOTH AND BLUETOOTH CONNECTION CONNECTION
Model THT33 is a thermal cameracamera with reduced size provided IR Model THT33 is a thermal with reduced size with provided with IR sensor with with resolution 80x80pxl, which makes the ideal device for device fo sensor resolution 80x80pxl, which itmakes it the ideal maintenance operations and everyday analysis. THT33 has an LCD maintenance operations and everyday analysis. THT33 has an LCD colour display and aand verya simple menu which a simple colour display very simple menuallows whichforallows for a simple programming. The temperature range isrange very wide (-20°C 380°C)to 380°C programming. The temperature is very wideto(-20°C andand it is itpossible to save imagesimages in a BMPinformat in the internal is possible to thermal save thermal a BMP format in the interna memory, or toortransfer the captured snapshots to mobiletodevices memory, to transfer the captured snapshots mobilethrough devices through the the dedicated APP APP HTMercury using the Bluetooth connection. Within dedicated HTMercury using the Bluetooth connection. Within the the APP,APP, it is itpossible to carry advanced is possible to out carry out advanced analyses and and createcreate PDF reports which can which can analyses PDF reports be be shared shared by mail by mail and/orand/or via social via networks. social networks. Thermal Thermal camera camera THT33 THT33 is theisideal the solution ideal solution for fordetecting detecting electric electric problems, problems, checkingchecking mechanical mechanical parts,parts, analyzing analyzing hydraulic hydraulic systems systems andand forced forced ventilation ventilation systems. systems.
App HT Mercury33 App HT Mercury33
Funzioni Funzionie ecaratteristiche caratteristiche Characteristics Characteristics of IR of and IR and integrated integratedoptics optics • Field • Field of view of view (FOV): (FOV): 21°x 21°x 21° 21° • Automatic focusing • Automatic focusing Functions Functions • 3 •cursors: 3 cursors: Central, Central, Max, Max, MinMin • Emissivity • Emissivity adjustable adjustable from from 0.10 0.10toto1.00 1.00 • 5 •colour 5 colour palettes palettes • Reading in °F °C, °F • Reading in °C, • HOLD • HOLD function function Data Data saving saving • BMP • BMP format format of saved of saved images images • Saving • Saving in thein internal the internal memory memory (max (max20 20images) images) • Download of images to mobile devicesvia via • Download of images to mobile devices Bluetooth HTMercury Bluetooth and and APPAPP HTMercury Additional characteristics Additional characteristics • Power • Power supply supply withwith rechargeable rechargeableLi-ION Li-IONbattery battery • USB • interface USB interface for battery for battery recharge recharge • Built-in white-light torch • Built-in white-light torch • Automatic/Manual • Automatic/Manual temperature temperaturespan span • D/S • ratio: D/S ratio: 74:174:1 Characteristics Characteristics of IR of image IR image • Resolution • Resolution of IRofsensor: IR sensor: 80x80pxl 80x80pxl • Temperature • Temperature range: range: -20°C -20°C ÷÷ 380°C 380°C • Thermal • Thermal sensitivity: sensitivity: <0.1°C <0.1°C @@30°C 30°C • NETD: • NETD: <100mK <100mK • Spectrum • Spectrum range: range: 8 ÷814µm ÷ 14µm • Type • Type of IRofsensor: IR sensor: UFPA UFPA • Frequency: • Frequency: 50Hz 50Hz
72
01274 752 407
01274 870 175
Included accessories Included accessories Built-in Built-in rechargeable rechargeable Li-IONLi-ION battery battery Battery Battery charger charger powerpower supplysupply USBUSB cablecable for battery for battery recharge recharge Carrying Carrying bag bag Non-slip Non-slip strapstrap UserUser Manual Manual
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
ORDER CODE HN000108
HTB500 BOROSCOPE WITH RECHARGEABLE BATTERY AND INTERCHANGEABLE PROBE HIGH RESOLUTION 640 x 480 PIXELS
Model HTB500 is a portable digital borescope which allows carrying out inspections inside parts of objects not physically accessible (typically rotating equipment) and not visible to the naked eye. The instrument uses a waterproof external feeler with 4 LEDs with high brightness and a photo camera, in order to obtain a highresolution image on the display.
ORDER CODE HA000036
BP36 IP67 PROBE FOR INSPECTIONS UP TO 3 METERS DEEP
Functions
Optional Accessories
•
Sensor size: ¼in (CMOS), 300.000pxl
•
Max sensor resolution: 640 x 480pxl
•
Max sampling frequency: 30FPS/S
•
Colour depth: 24bit
•
Full Colour Display
•
Image focus: fixed (5cm ÷ 15cm) (2.0in ÷ 5.9in)
•
Zoom image: 1.0x ÷ 2.0x
•
External probe length: 1m (39in)
•
Probe diameter: 6mm (0.2in)
•
Illumination: 4 LED white light
•
Brightness adjustment: 10 levels
•
Rechargeable battery: Li-ION, 2000mAh
•
Low battery indication
•
Battery Duration: 5 hours approximately
•
Size (LxWx H) (mm): 250 x 100 x 95mm
•
Weight in grams (batteries included): 345g
•
Colour LCD display: 640 x 320pxl
•
Mechanical protection: IP54 (instrument), IP67 (external probe)
•
PAL / NTSC video output
01274 752 407
01274 870 175
BP36
IP67 probe 3 meters long
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
73
ORDER CODE HV006050 | HV006055
QUICKLAN6050 Network Cable Wire Mappers QUICKLAN6055 QUICKLAN6050 QUICKLAN6050 QUICKLAN6055 QUICKLAN6055 QUICKLAN6050 QUICKLAN6055
LAN LAN TESTERS TESTERS
ORDER ORDERCODE CODEHV006050 HV006050 | HV006055 | HV006055
WIRE MAPPERS FOR CABLE TESTS IN LOCAL AREA NETWORKS
LAN TESTERS
ORDER HV006050 | HV006055 MobileCODE devices QUICKLAN6050
and QUICKLAN6055 are capable
WIRE WIRE MAPPERS MAPPERS FOR FORCABLE CABLE TESTS of detecting and indicating at the TESTS display the presence of incorrect IN IN LOCAL LOCALAREA AREA NETWORKS NETWORKS connections on LAN cables (crossed, reversed, split, open, short-
circuited , pairs, etc.) both of type UTP (not screened) and of type STP or devices FTP (shielded or failed). Model allowsaremeasuring Mobile Mobile devices QUICKLAN6050 QUICKLAN6050 andandHT6050also QUICKLAN6055 QUICKLAN6055 are capable capable cable lengthand saving theatresults ofdisplay the tests in its internal ofof detecting detecting andindicating indicating atthethedisplay thethe presence presence of incorrect ofmemory. incorrect Each model on isonprovided with(crossed, more remote unitssplit, and is open, capable of connections connections LAN LANcables cables (crossed, reversed, reversed, split, open, shortshortrecognizing further (optional) ones, in(not order to create circuited circuited , ,pairs, pairs, etc.) etc.) both both of oftype type UTP UTP (not screened) screened) andand ofantype ofefficient type WIRE MAPPERS FOR CABLE TESTS localization action NETWORKS on different spots inside a patch panel, carrying STP STP ororFTP FTP(shielded (shielded ororfailed). failed). Model Model HT6050also HT6050also allows allows measuring measuring IN LOCAL AREA out tests veryand quickly withthethe the aid ofof aof HT6050 and cable cable length length and saving saving results results thesingle the tests tests inoperator. its in internal its internal memory. memory. HT6055 areisthe ideal solution for any installer whoand needs simple and Each Each model model isprovided provided with withmore more remote remote units units and is are capable is capable of of Mobile devices QUICKLAN6050 and QUICKLAN6055 capable efficient devices to carry outat ones, preliminary checks andcreate verifications on recognizing recognizing further further (optional) (optional) ones, in inorder order to create an incorrect an efficient efficient of detecting and indicating the display the to presence of installations of LAN cables with connectors type RJ45. localization localization action action on on different different spots spots inside inside a patch a patch panel, panel, carrying carrying connections on LAN cables (crossed, reversed, split, open, shortout outtests testsvery very quickly quickly withthe aid ofUTP of a single a(not single operator. operator. HT6050 circuited , pairs, etc.)with both oftheaid type screened) and ofHT6050 type and and HT6055 HT6055 are are the the ideal ideal solution solution for for any any installer installer who who needs needs simple simple and and STP or FTP (shielded or failed). Model HT6050also allows measuring efficient efficient devices devices tocarry carryout preliminary preliminary checks andinternal and verifications verifications on on cable length andtosaving theout results of the checks tests in its memory. installations installations LAN cables cables with with connectors connectors type type RJ45. RJ45. Each modelofofisLAN provided with more remote units and is capable of recognizing further (optional) ones, in order to create an efficient localization action on different spots inside a patch panel, carrying out tests very quickly with the aid of a single operator. HT6050 and HT6055 are the ideal solution for any installer who needs simple and efficient devices to carry out preliminary checks and verifications on installations of LAN cables with connectors type RJ45.
Functions HT6050 Cable mapping on LAN networks • ChecksFunctions on twisted pair cables RJ45 Functions • type UTP, STP and FTP HT6050 HT6050 Verification on COAX cables • Cable Cable mapping mapping onon LAN LANnetworks networks ••• Errors of open pairs Checks Checks on twisted twistedpair paircables cables RJ45 Errorsonof short-circuited pairsRJ45 ••• type type UTP, UTP, STP STP and andFTP FTP Errors of exchanged pairs • Verification Verification onFunctions on COAX COAXcables cables •• Errors of inverted pairs • Errors Errors of of open open pairs pairs •• Errors of split pairs • HT6050 Errors Errors of of short-circuited short-circuitedpairs pairs •• Generic errors (MISWIRE) Cable mapping onpairs LAN Errors Errors of of exchanged exchanged pairsnetworks ••• Display indication ofpair error type RJ45 • Checks on twisted cables Errors Errors of of inverted invertedpairs pairs ••• Indication of test • type UTP, STP andpassed/failed FTP Errors Errors of of split split pairs pairs •• Remote unitonrecognition •(4) Verification COAX cables • Generic Generic errors errors (MISWIRE) (MISWIRE) Measurement cable length Errors of open of pairs • Display Display indication indicationof oferror errortype type •• Cable of length measuring pairs range 1 ÷ •350m Errors short-circuited Indication Indication of of testtest passed/failed passed/failed •• Internalofmemory for measured Errors exchanged pairs data saving • Remote Remote unitunit recognition recognition •(4) •(4) Memory locationspairs 99 Errors of inverted • Measurement Measurement of of cable cablelength length •• Recalling and pairs deletion of saved data Errors of split • Cable Cable length length measuring measuringrange range 11÷÷350m 350m AutoPowerOFF • Generic errors (MISWIRE) Internal Internal memory memory forfor measured measureddata datasaving saving •• Low battery indication Display indication of error type • Memory Memory locations locations 99 99 Indication of test passed/failed • 126 Recalling Recalling andand deletion deletionofofsaved saveddata data •• Remote unit recognition •(4) AutoPowerOFF AutoPowerOFF •• Measurement of cable length • Low Low battery battery indication indication •• Cable length measuring range 1 ÷ 350m 126 126 Internal memory for measured data saving • Memory01274 locations 752 407 0127499870 Recalling and deletion of saved data •
74
Main features HT6055 • • HT6055 •• •• • • • • HT6055 • • •• • •• • • •(8) • •• •• ••(8) •-•-• -• -• •(8) • •
175 -
HT6050
HT6055
Input connectors RJ45, BNC RJ45 Main Mainfeatures features Protection: (50V) (30V) against voltages HT6050 HT6050 HT6055 HT6055 Power supply 6x1.5V type AAA 1x9V type 6F22 Input Input connectors connectors RJ45, RJ45, BNC BNC RJ45 RJ45 (alkaline batteries) Protection: Protection: Size (LxWxH): 150x72x35mm 128x672x39mm (50V) (50V) (30V) (30V) against againstvoltages voltages Weight (batteries 215g 165g Main features Power Powersupply supply included): 6x1.5V 6x1.5V type type AAAAAA 1x9V 1x9V typetype 6F22 6F22 (alkaline (alkalinebatteries) batteries) HT6050 HT6055 Size Size(LxWxH): (LxWxH): 150x72x35mm 150x72x35mm 128x672x39mm 128x672x39mm Input connectors RJ45, BNC RJ45 Weight Weight(batteries (batteries Accessories215g provided 215g 165g 165g Protection: included): included): (50V) (30V) against voltages Remote unit #1 (only HT6050) 6050MARKER01 Power supply 6x1.5V type AAA 1x9V type 6F22 CH1, CH2 batteries)Remote unit #1 and #2 (only HT6055) (alkaline Accessories Accessories provided provided(only HT6050) 2 patch cables FTP RJ45-RJ45, 20cm Size (LxWxH): 150x72x35mm 128x672x39mm 3 patch cables FTP RJ45-RJ45, 20cm (only HT6055) Weight (batteries 215g 165g Remote Remote unitunit #1bag #1 (only (only HT6050) HT6050) 6050MARKER01 6050MARKER01 Soft carrying included): Remote Remote unit unit #1 #1 and and #2 #2 (only (only HT6055) HT6055) CH1, CH1,CH2 CH2 User Manual 2Batteries patch 2 patch cables cables FTPFTP RJ45-RJ45, RJ45-RJ45, 20cm 20cm (only(only HT6050) HT6050) 3For patch 3 patch cables cables FTP FTP RJ45-RJ45, RJ45-RJ45, 20cm 20cm (only (only HT6055) HT6055) optional accessories, please refer to the table here toSoft the side. bagbag Soft carrying carrying
Accessories provided User User Manual Manual
Remote unit #1 (only HT6050) 6050MARKER01 Batteries Batteries Remote unitaccessories, #1accessories, and #2 (only HT6055) CH1, CH2 For For optional optional please please referrefer to the to table the table here here to2to the the side. side. patch cables FTP RJ45-RJ45, 20cm (only HT6050) 3 patch cables FTP RJ45-RJ45, 20cm (only HT6055) carrying bag contact your local wholesaler for pricing sales@tis-tic.co.uk PleaseSoft User Manual
ORDER CODE HP030000
CAT IV 600V CAT III 1000V
F3000 CLAMP METER WITH FLEXIBLE CLAMP JAWS AC 3000A Professional clamp meter F3000 has been designed to measure AC current up to 3000A in TRMS in total autorange to reach CAT IV 600V, CAT III 1000V according to standard IEC/EN61010-1. The clamp is provided with innovative flexible jaws capable of reaching a maximum diameter of 110mm and allowing for an easy reading in any condition. The clamp is provided with a wide display with 3000 measuring spots, Data HOLD function and Backlight to allow for a simple reading even in poorly lit environments. The clamp is also provided with the auto power off function to preserve its own battery.
Technical Specifications
Functions • • • • • • • •
AC TRMS current • Measuring range: 0.1A ÷ 3000A • Resolution: 0.01 ÷ 1A • Frequency range: 45Hz ÷ 500Hz • Basic accuracy: ±(3%reading + 5digits)
TRMS measurements AC TRMS current up to 3000A Flexible jaws with big diameter Autorange Data HOLD MAX/MIN Backlight Auto Power OFF
Accessories provided
Main features Display: Conversion type: Power supply: Auto Power OFF: Max diameter of clamp: Safety: Measurement category: Insulation: Pollution level: Size (LxWxH): Weight (batteries included):
01274 752 407
LCD, 4 digits, 3000 dots TRMS 2x1.5V alkaline batteries type AAA LR03 after 20 minutes’ idling 110mm IEC/EN61010-1 CAT IV 600V – CAT III 1000V double insulation 2 280x120x25mm 170g
01274 870 175
Batteries Soft carrying bag User Manual
187
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
75
ORDER ORDER ORDERORDER CODE CODE CODEHV007051 HV007051 CODE HV007051 HV007051
CAT CAT CAT IVIV CAT IV IV 600V 600V 600V600V CAT IV 600V
HT7051 HT7051 HT7051 HT7051 HT7051
ORDER CODE HV007051
PROFESSIONAL PROFESSIONAL PROFESSIONAL PROFESSIONAL INSULATION INSULATION INSULATION INSULATION METER METER METER METER WITH WITH WITHWITH PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE PROGRAMMABLE TEST TEST TESTVOLTAGE TEST VOLTAGE VOLTAGE VOLTAGE UP UP TO TO TO UP 5KV 5KV 5KV TO 5KV PROFESSIONAL INSULATION METER WITH PROGRAMMABLE TEST VOLTAGE HT7051 HT7051 HT7051 has has hasbeen been been has developed developed been developed developed tototomeasure measure measure to measure insulation insulation insulation insulation resistance resistance resistance resistance UP TOHT7051 5KV
with withtest test test with voltage voltage voltage test voltage programmable programmable programmable programmable up up up tototo 5kVDC 5kVDC up 5kVDC to 5kVDC and and and measuring measuring measuring and measuring range range rangerange up up to to to 10TΩ up 10TΩ 10TΩ to 10TΩ which which which which makes makes makes it it it very very very useful it useful useful very in useful in any in any any industrial in industrial industrial any industrial application application application application HT7051 has been developed to measure insulation resistance (tests (tests (tests (tests on on on electric electric electric on programmable electric machines, machines, machines, machines, power power power power transformers, transformers, transformers, transformers, electric electric cables, electric cables, cables, cables, with test voltage up to 5kVDC andelectric measuring range electric electric electric electric boards, boards, boards, boards, generic generic generic generic devices, devices, devices, devices, etc.). etc.). etc.). The The etc.). The device device device The allows device allows allows carrying allows carrying carrying carrying up to 10TΩ which makes it very useful in any industrial application out outtests tests tests out tests inFIX FIX FIXin(with (with (with FIX fixed (with fixedtest test fixed test voltages), voltages), voltages), test transformers, voltages), ADJUST ADJUST ADJUST ADJUST (programmable (programmable (programmable (programmable (tests on inin electric machines, power electric cables, test testvoltage) voltage) voltage) test voltage) and and and RAMP RAMP RAMP and RAMP mode mode mode(programmable mode (programmable (programmable test test test voltage voltage voltage testcarrying voltage and and and and electric boards, generic devices, etc.).(programmable The device allows application application application application time time time with time with selection selection with selection selection of of of 3 3 3 available available of available 3 available ramp ramp ramp types) ramp types) types) out tests in FIX (with fixed test voltages), ADJUST (programmabletypes) which which which define which define definedefine aaakind kind kind aofof kind operation operation operation of operation suitable suitable suitable suitable for forfor any any any situation. for situation. situation. anyvoltage situation.and test voltage) and RAMP mode (programmable test Measurement Measurement Measurement Measurement of of of parameters parameters parameters of parameters such such such as as such as Polarization Polarization Polarization as Polarization Index Index Index (PI) Index (PI) (PI) andand and (PI) and application time with selection of 3 available ramp types) Dielectric Dielectric Dielectric Dielectric Absorption Absorption Absorption Absorption Ratio Ratio Ratio (DAR), (DAR), Ratio (DAR), (DAR), are are are duration duration duration are duration tests tests tests which which tests which allow allow which allow allow which define a kind of operation suitable for any situation. defining defining defining defining the the thequality quality quality quality ofofinsulation. insulation. insulation. of such insulation. HT7051 HT7051 HT7051 HT7051 isissupplied issupplied supplied isIndex supplied with with with NiMH NiMH with NiMH Measurement oftheparameters as Polarization (PI) and NiMH rechargeable rechargeable rechargeable rechargeable battery battery battery battery with with withintegrated integrated integrated with integrated battery battery battery charger, battery charger, charger, charger, which which which allows allows which allowsallows Dielectric Absorption Ratio (DAR), are duration tests which allow forforaaaremarkable for remarkable remarkable a remarkable duration duration when when whencarrying carrying when carrying carrying out out measurements, measurements, measurements, out measurements, isit itisis it is defining the qualityduration of insulation. HT7051 isout supplied with itNiMH provided provided provided provided with with withinternal internal internal with internal memory memory memory memory for forforsaving saving saving for measurements saving measurements measurements measurements and and and it it itand it rechargeable battery with integrated battery charger, which allows is is also also also is possible possible also possible possible to to to connect connect connect to connect for a remarkable duration when carrying out measurements, it is itprovided ittotothe the the it to PC PC PC the tototointernal PC download download download to download the the the thefor saving measurements and it with memory measured measured measured measured results. results. results. results. The The whole whole whole The is also possible to connect whole structure structure structure has has has been been has inserted inserted been inserted inserted it structure to the PC to been download the into into into aaa comfortable comfortable comfortable a comfortable and and and and measured results. The whole resistant resistant resistant resistant transport transport transport transport case, case, solid solid case, solid solid structure has been inserted and andsafe safe safe and for for safe “on-site” “on-site” “on-site” for “on-site” use. use. into a for comfortable anduse. resistant transport case, solid and safe for “on-site” use.
Included Included Included Included accessories accessories accessories accessories
Functions Functions Functions Functions and and and and characteristics characteristics characteristics characteristics •• •• •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • •• • • •
Functions and characteristics Insulation Insulation •• Insulation Insulation with withtest with test with voltage test voltage testvoltage voltage from fromfrom 100V 100V from 100V to 100V to5kVDC 5kVDC to 5kVDC to 5kVDC Measuring Measuring •• Measuring Measuring range rangerange up range uptotoup 10TΩ up 10TΩ toto10TΩ 10TΩ Measurement Measurement •• Measurement Measurement with withfixed with fixed withfixed test test fixed voltages test voltages testvoltages voltages Insulation with test voltage from 100V to and 5kVDC 33test •test • 3 ramps, 3ramps, test test ramps, ramps, programmable programmable programmable programmable inintime time in in time and and time voltage voltage and voltage voltage Measuring range up to 10TΩ SMOOTH SMOOTH •• SMOOTH SMOOTH function function function function for forsteady steady forforsteady steady measurement measurement measurement measurement results results results results Measurement with fixed test voltages Measurement Measurement •• Measurement Measurement ofofdielectric dielectric ofofdielectric dielectric discharge discharge discharge discharge current current current current 3 test ramps, programmable inindex time and(P.I.) voltage Measurement Measurement •• Measurement Measurement ofofpolarization polarization ofofpolarization polarization index index (P.I.) index (P.I.) (P.I.) SMOOTH function for measurement results Measurement Measurement •• Measurement Measurement ofofdielectric dielectric ofofsteady dielectric dielectric absorption absorption absorption absorption ratio ratio ratio (D.A.R.) (D.A.R.) ratio (D.A.R.) (D.A.R.) Measurement of dielectric discharge current Measurement Measurement •• Measurement Measurement ofofdischarge discharge ofofdischarge discharge capacity capacity capacity capacity Measurement ofvoltage polarization index (P.I.) DC/AC DC/AC •• DC/AC DC/AC TRMS TRMS TRMS TRMS voltage voltage voltage up uptoto up 600V up 600V to to600V 600V Measurement of dielectric absorption ratio (D.A.R.) Rechargeable Rechargeable •• Rechargeable Rechargeable internal internal internal internal NiMH NiMH NiMH battery NiMH battery battery battery Measurement of discharge capacity GUARD GUARD •• GUARD GUARD terminal terminal terminal terminal DC/AC TRMS voltage tooftest 600V Automatic Automatic •• Automatic Automatic discharge discharge discharge discharge ofup ofthe the of the test the object test object test object object Rechargeable internal NiMH Display: Display: •• Display: Display: Custom Custom Custom Custom LCD LCD LCD with with LCDbattery with backlight with backlight backlight backlight and and and bargraph bargraph and bargraph bargraph GUARD terminal External External •• External External supply: supply: supply: supply: power power power power 220-240V, 220-240V, 220-240V, 220-240V, 50/60Hz, 50/60Hz, 50/60Hz, 50/60Hz, 20VA 20VA 20VA 20VA Automatic discharge ofrechargeable the test object Internal Internal •• Internal Internal supply: supply: supply: supply: rechargeable rechargeable rechargeable internal internal internal internal NiMH NiMH NiMH NiMH battery battery battery battery Display: Custom LCD and bargraph Protection Protection •• Protection Protection fuse: fuse:fuse: Tfuse: T200mA 200mA Twith T200mA 200mA Hbacklight H250V 250V HH 250V 250V External supply: 220-240V, 50/60Hz, 20VA Battery Battery •• Battery Battery life: life:>1000 life: >1000 life:power >1000 >1000 tests tests tests (@ tests (@5kV (@ 5kV (@ 5kV on on 5kV 5MΩ) on 5MΩ) on 5MΩ) 5MΩ) Internal supply: rechargeable internal NiMH AutoPowerOFF: AutoPowerOFF: •• AutoPowerOFF: AutoPowerOFF: after afterafter 5after 5minutes’ minutes’ 5 5minutes’ minutes’ idling idling idling idling battery Protection fuse: T 700 200mA Hlocations 250V Internal Internal •• Internal Internal memory: memory: memory: memory: 700locations 700 locations 700 locations Battery life:interface: >1000 tests (@ 5kV on 5MΩ) Serial Serial •• Serial Serial interface: interface: interface: RS-232 RS-232 RS-232 RS-232 optically optically optically optically insulated insulated insulated insulated AutoPowerOFF: after 5 minutes’ idling Safety: Safety: •• Safety: Safety: IEC/EN61010-1, IEC/EN61010-1, IEC/EN61010-1, IEC/EN61010-1, IEC/EN61557-1 IEC/EN61557-1 IEC/EN61557-1 IEC/EN61557-1 Internal memory: 700 locations Insulation: Insulation: •• Insulation: Insulation: double double double double insulation insulation insulation insulation Serial interface: Pollution Pollution •• Pollution Pollution level: level: level: 2 level: 2RS-232 2 2 optically insulated Safety: IEC/EN61010-1, IEC/EN61557-1 Mechanical Mechanical •• Mechanical Mechanical protection: protection: protection: protection: IP53 IP53 IP53 (closed IP53 (closed (closed (closed case) case) case) case) Insulation: double insulation Measurement Measurement •• Measurement Measurement category: category: category: category: CAT CATCAT IVIV CAT 600 600 IV IV 600 (to (to 600 earth), (to earth), (to earth), earth), Pollution 2 weight: Size Size •• (LxWxH) Size (LxWxH) Sizelevel: (LxWxH) (LxWxH) and and and weight: andweight: weight: 360x310x195 360x310x195 360x310x195 360x310x195 mm, mm, mm, approx. mm, approx. approx. approx. 3.5kg 3.5kg 3.5kg 3.5kg Mechanical protection: IP53 (closed case) Measurement category: CAT IV 600 (to earth), Size (LxWxH) and weight: 360x310x195 mm, approx. 3.5kg
76
01274 752 407
01274 870 175
Included Set Set Setofaccessories of3Set 3cables cables cables of 3 with cables with with alligator alligator alligator with alligator clips clips clips clips
KIT14000 KIT14000 KIT14000 KIT14000
C7051 C7051 C7051C7051 KIT14000 BORSA2000 BORSA2000 BORSA2000 BORSA2000 C7051 TOPVIEW TOPVIEW TOPVIEW TOPVIEW BORSA2000 TOPVIEW
+ ++22cables cables cables + 2 cables with with with leads leads leads with leads Power Power Power supply supply Power supply cable supply cable cable Europlug-Schuko Europlug-Schuko cable Europlug-Schuko Europlug-Schuko with with nonono with no Set of 3 cables with alligator clips with earthing earthing earthing earthing + 2 cables with leads Transport Transport Transport Transport bag bag bag for forfor bag accessories accessories accessories for accessorieswith no Power supply cable Europlug-Schuko earthing Windows Windows Windows Windows software software software software for forfor PC PC PC +for +cable +cable PC cable + RS-232 RS-232 cable RS-232 RS-232 Transport bag forcalibration accessories ISO9000 ISO9000 ISO9000 ISO9000 calibration calibration calibration certificate certificate certificate certificate Windows software User User UserManual Manual Manual User Manualfor PC + cable RS-232 ISO9000 calibration certificate User Manual
Optional Optional Optional Optional accessories accessories accessories accessories C2009 C2009 C2009C2009 RS232-USB RS232-USB RS232-USB RS232-USB adapter adapter adapter adapter Optional accessories C2009
RS232-USB adapter
6565 65 6
sales@tis-tic.co.uk Please contact your local wholesaler for pricing 65
INSULATION INSULATION ANDCONTINUITY CONTINUITY AND MEASURING MEASURING DEVICES DEVICES
ORDER ORDER CODE CODE HV007052 HV007052
HT7052 HT7052
CAT CATIVIV 600V 600V
PROFESSIONAL PROFESSIONAL INSULATION INSULATION METER METER WITH WITH TEST TEST VOLTAGE VOLTAGE UP TO UP 10KV TO 10KV DC DC HT7052 hashas beenbeen developed to measure insulation resistance HT7052 developed to measure insulation resistance withwith testtest voltage programmable up to up 10kVDC and measuring voltage programmable to 10kVDC and measuring range up up to 10TΩ which makes it veryit useful in any inindustrial range to 10TΩ which makes very useful any industrial application (tests on electric machines, powerpower transformers, application (tests on electric machines, transformers, electric cables, electric boards, generic devices, etc.). The device electric cables, electric boards, generic devices, etc.). The device allows measuring parameters such such as Polarization Index Index allows measuring parameters as Polarization (PI)(PI) andand Dielectric Absorption RatioRatio (DAR)(DAR) and Dielectric Dielectric Absorption and Dielectric Discharge (DD), diagnostic tests tests whichwhich allow allow determining the the Discharge (DD), diagnostic determining quality of an material. It carries out “ramp” insulation quality of insulating an insulating material. It carries out “ramp” insulation tests andand dielectric strength test test in DC. is supplied tests dielectric strength inHT7052 DC. HT7052 is supplied withwith NiMH rechargeable battery with integrated batterybattery charger,charger, NiMH rechargeable battery with integrated which allows for for a remarkable duration when when carrying out out which allows a remarkable duration carrying measurements, it is itprovided with internal memory for saving measurements, is provided with internal memory for saving measurements and and it is italso possible to connect it to the PCthe to PC to measurements is also possible to connect it to download the the measured results. The device has been download measured results. The device has inserted been inserted intointoa acomfortable and and comfortable resistant transport case,case, solidsolid resistant transport andand safesafe for “on-site” use. use. for “on-site”
ATION CONTINUITY URING ES
ORDER CODE HV007052
CAT IV 600V
HT7052 PROFESSIONAL INSULATION METER WITH TEST VOLTAGE UP TO 10KV DC
• • • • • • • • • • • • • • • • • • • • • • • • • •
HT7052 has been developed to measure insulation resistance with test voltage programmable up to 10kVDC and measuring range up to 10TΩ which makes it very useful in any industrial application (tests on electric machines, power transformers, generic devices, etc.). The device Functionsand and characteristics characteristicselectric cables, electric boards,Included Functions Included accessories accessories allows measuring parameters such as Polarization Index (PI) and Dielectric Absorption Ratio (DAR) and Dielectric •Insulation Insulation with withtest testvoltage voltagefrom from500 500 to to 10kVDC 10kVDC inin steps stepsofof25VDC 25VDC terminal, protection 10kV, 2m 2m Red terminal, protection Discharge (DD), diagnostic tests Red which allow determining the 10kV, •Measuring Measuring range rangeupuptoto10TΩ 10TΩ quality of an insulating material. It carries out (red/black), “ramp” insulation Terminals protection 10kV, 2m, 2 pieces Terminals (red/black), protection 10kV, 2m, 2 pieces •Timer Timer programmable programmablefrom from1s1stoto30min 30min •Diagnostic Diagnostic tests testsononmaterials materials(PI, (PI,DAR, DAR, DD) DD) tests and dielectric strength testTerminals in Terminals DC. HT7052 is supplied (red/black), protection 10kV, 210kV, pieces (red/black), protection 2 pieces •Insulation Insulation resistance resistancewith withprogrammable programmable “ramp” “ramp” with NiMH rechargeable battery with integrated battery charger, Green guard terminal Green guard terminal •Dielectric Dielectric strength strengthupuptoto10kVDC 10kVDC which allows for a remarkable duration when carrying out •Measurement Measurement DC/ACvoltage voltageup up toto 600V 600V of ofDC/AC 5004-IECV Green alligator clip 5004-IECV Green alligator clipsaving measurements, it is provided with internal memory for •Measurement Measurement capacityofofthe thetarget target of ofcapacity Power supply cable supply measurements and it is also possible toPower connect it tocable the PC to •GUARD GUARD terminalforforsurface surfacecurrent current compensation compensation terminal download the measured results. The has been inserted USBdevice cablecable USB •Automatic Automatic dischargeofoftest testobject object discharge into a comfortable and •Backlight Backlight display display Cable RS-232 Cable RS-232 •Internal Internal memoryforforsaving savingresults results memory resistant transport case, solid Software “TeraView” on CD-ROM Software “TeraView” on CD-ROM •Recalling Recalling thedisplay displaythe thesaved saved results results onon the and safe for “on-site” use. •RS-232 RS-232 and USBserial serialinterface interfacefor for transferring transferring data and USB dataonto ontothe thePC PC •Power Power supplywith withrechargeable rechargeable battery battery supply
from power from power •Display: Display: CustomLCD LCDwith withbacklight backlight and and bargraph Custom bargraph •External External powersupply: supply:90-260V 90-260V AC, AC, 45-65Hz, 45-65Hz, 70VA power 70VA •Internal Internal powersupply: supply:rechargeable rechargeable batteries batteries power •Duration: Duration: 4 hours(test (testwith with10kV) 10kV) 4 hours •Internal Internal memory:1000 1000locations locations memory: •PC PC interface: RS232and andUSB USB interface: RS232 •Insulation: Insulation: doubleinsulation insulation double •Pollution Pollution level:2 2 level: •Mechanical Mechanical protection:IP53 IP53(closed (closed case) case) protection: •Measurement Measurementcategory: category:CAT CATIVIV 600V 600V •Size Size (LxWxH)and andweight: weight:330x360x160mm, 330x360x160mm, 5.5kg (LxWxH) 5.5kg
6 x 1.2V rechargeable batteries NiMH IEC LR20 6 x 1.2V rechargeable batteries NiMH IEC LR20 UserUser Manual Manual ISO9000 calibration certificate ISO9000 calibration certificate
Optional Optional accessories accessories ForFor further information on optional accessories, pleaseplease contactcontact HT. HT. further information on optional accessories,
64 64
unctions and characteristics 01274 752 407
01274 870 175
Included accessories
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
77 Fu
Test Instrument Calibrations Instruments must be calibrated in line with the manufacturers recommendations and the requirements of BS EN 61557 and in line with the New IET Legislation, which in most instances is a “12 month” re-calibration cycle.
78
01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
Our Calibration Service Our service includes full certified calibration, traceable to UKAS Standards and ISO 9001; together with a computerised recall service which will log all your instruments by type, manufacturer, serial number and remind you of when they are due for re-calibration. We are able to calibrate most instruments from any manufacturer including:
Insulation, Loop Or RCD Testers
Multi-Functional All In One Testers
Portable Appliance Testers
Digital Thermometers
Multimeters
Microwave Testers
Earth Resistance Testers
Sound Level Meters
Phase Rotation Testers
Check Boxes
Light Meters & Voltage Testers
Torque Screwdrivers
Plus Much More - Please Ask!
“Mini” On-Site Calibration Service and On Site Calibration Service available 01274 752 407
01274 870 175
sales@tis-tic.co.uk Please contact your local wholesaler for pricing
79
Telephone: 01274 752 407 Fax: 01274 870 175 Email: sales@tis-tic.co.uk Web: www.testinstrumentsolutions.co.uk Test Instrument Solutions
Unit 12/14 Luddite Way Business Park, Rawfolds Way, Rawfolds, Cleckheaton, BD19 5DQ
Click any of the above links to follow TIS on Social Media © Copyright Test Instrument Solutions 2021. Printing errors and omisissions excepted.