GENERAL CONTRACT REQUIREMENTS AFFECTING ALL TRADES

1. ALL WORK IS TO BE DONE IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THE LOCAL JURISDICTION. UNLESS OTHERWISE AGREED UPON, THE GENERAL CONTRACTOR IS RESPONSIBLE FOR SECURING ALL BUILDING PERMITS AS REQUIRED FOR WORK HE IS TO PERFORM AND WILL RETAIN AND PAY FOR ALL REQUIRED INSPECTIONS DURING THE COURSE OF THE WORK.

2. ANY DISCREPANCIES FOUND IN THE PLANS, DIMENSIONS, EXISTING CONDITIONS, CONSULTANT DRAWINGS, OR ANY APPARENT ERROR IN CLASSIFYING OR SPECIFYING A PRODUCT OR ITS USE IS TO BE POINTED OUT TO THE ARCHITECT PRIOR TO COMMENCEMENT OF WORK. ADDENDA WILL BE ISSUED AS NECESSARY AND WILL BECOME PART OF THE CONTRACT DOCUMENTS. FOR THOSE DISCREPANCIES NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT, IT WILL BE ASSUMED THAT THE CONTRACTOR HAS BID THE MORE EXPENSIVE METHOD OF CONSTRUCTION.

3. ANY DAMAGE TO NEW OR EXISTING CONSTRUCTION CAUSED BY THE CONTRACTOR'S NEGLIGENCE OR INADEQUATE PROTECTIVE OR SECURITY MESASURES DURING CONSTRUCTION ARE TO BE CORRECTED AT HIS EXPENSE.

4. THE CONTRACTOR FOR A PERIOD OF ONE YEAR FROM THE DATE OF COMPLETION AND ACCEPTANCE BY TENANT, SHALL ADJUST, REPAIR, OR REPLACE AT NO COST TO THE TENANT ANY ITEM OF EQUIPMENT, MATERIAL, OR WORKMANSHIP FOUND TO BE DEFECTIVE, INCLUDING OR AFFECTED WITHIN THE SCOPE OF THE CONTRACT.

OCCUPANCY CLASSIFICATION:

OCCUPANCY LOAD FACTOR:

BUILDING OCCUPANCY

WOMEN:

BUSINESS: GROUP B

ONE OCCUPANT PER 150 SQUARE FEET

(9,700 SQ. FT. PER FLOOR = 65 PERSON MAX OCCUPANCY PER FLOOR)

48 TOTAL EMPLOYEES

ADA WATER CLOSET STANDARDS

3

24

3

ABBREVIATIONS

@ AT

A.B. ANCHOR BOLT

AHU AIR HANDLER UNIT

APRX APPROXIMATE

BD BOARD

BLDG. BUILDING

BOH BACK OF HOUSE

B.O. BOTTOM OF

B.O.S. BOTTOM OF SLAB

B.O.B. BOTTOM OF BEAM

CAB CABINET

CLR CLEAR

COL COLUMN

CONC CONCRETE

DTL DETAIL

DIA DIAMETER

DWG DRAWING

EA EACH

EL. ELEVATION

EQ EQUAL

F.F. FINISH FLOOR

F.V. FIELD VERIFY

FACP FIRE ALARM CONTROL

PANEL

F.D. FLOOR DRAIN

FOH FRONT OF HOUSE FRP FIBERGLASS REINFORCED

PLASTIC

GA GAUGE GYP GYPSUM

HDW HARDWARE

HOR. HORIZONTAL

JT. JOINT

LF LINEAR FEET

MAX MAXIMUM

MECH MECHANICAL

MTL METAL

MIN MINIMUM

N/A NOT APPLICABLE

N.I.C. NOT IN CONTRACT

N.F.C. NOT FOR CONSTRUCTION

N.T.S. NOT TO SCALE

#/NO. NUMBER

O.C. ON CENTER

O.D. OUTSIDE DIMENSION

RM ROOM

REQD REQUIRED

R.O. ROUGH OPENING

SF SQUARE FOOT

SIM SIMILAR

SPEC SPECIFICATION

STL STEEL

SUSP SUSPEND

T.O. TOP OF

T.O.B. TOP OF BEAM

T.O.S. TOP OF SLAB

TYP TYPICAL

VERT. VERTICAL

VIF VERIFY IN FIELD W/ WITH

LEVEL

A100 TITLE

A101 INDEX

A102 CODE PLANS

A103 ACCESSIBILITY

A104 ACCESSIBILITY SCHEDULE

A105 EXISTING LEVEL 6 FLOOR PLAN

A106 EXISTING LEVEL 7 FLOOR PLAN

A110 NEW LEVEL 6 FLOOR PLAN

A111 NEW LEVEL 7 FLOOR PLAN

A120 NEW LEVEL 6 REFERENCE PLAN

A121 NEW LEVEL 7 REFERENCE PLAN

A130 NEW LEVEL 6 RCP

A131 NEW LEVEL 7 RCP

A301 BUILDING SECTIONS

A400 EXISTING 7F PLAN CALLOUT BRAND POP-UP

A401 STAIR PLAN

A402 STAIR DETAIL SECTION

A403 STAIR DETAIL DRAWINGS

A404 STAIR RENDERED AXONOMETRIC

A410 POP UP PLAN

A411 POP UP RCP

A412 POP UP DETAIL SECTION (E-W)

A413 POP UP DETAIL SECTION (N-S)

A414 POP UP INTERIOR ELEVATIONS

A415 POP UP CASEWORK DETAILS

A416 POP UP RENDERED AXONOMETRIC

A601 ROOM FINISH SCHEDULE

A610 WALL SCHEDULE

A611 DOOR SCHEDULE

E101 ELECTRICAL PLAN - BRAND POP-UP

FP101 FIRE PROTECTION

M101 MECHANICAL PLAN - LEVEL 6

M102 MECHANICAL PLAN - LEVEL 7

M103 MECHANICAL DETAILS

BEYOND ADVERTISING AGENCY

ACCESSIBILITY PLAN LEGEND

4' - 0" CLEAR ACCESSIBILITY PATH

3' - 0" CLEAR ACCESSIBILITY PATH

3' - 0" 4'4" 36" x 52" FLOOR CLEARANCE/APPROACH

5' - 0" CLEAR SPACE FOR TURNING RADIUS x x DOOR APPROACH CLEARANCE

CATEGORY

ALTERATION

ACCESSIBLE ROUTE

AREAS OF RESCUE ASSISTANCE

CURB RAMPS

RAMPS

STAIRS

ELEVATOR

DOORS

ACCESSIBILITY REQUIREMENTS

REFERENCE REQUIREMENT(S)

CHAPTER 11

ACCESSIBLE ENTRANCE AS REQUIRED

DRINKING FOUNTAIN KITCHENETTE

RECEPTION COUNTER

CHAPTER 11

CHAPTER 11

CHAPTER 11

CHAPTER 11

CHAPTER 11

CHAPTER 11

CHAPTER 11 / ANSI 404

CHAPTER 11

CHAPTER 11

CHAPTER 11 SEC. 804

CHAPTER 11 SEC. 904.2

COMPLIANCE AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED N/A N/A N/A N/A

& 18" ON PULL

COUNTER

TOILET ROOMS AS REQUIRED

CHAPTER 11

CONTROLS & OPERATING MECH. REACH RANGE 15" & 48" AFF

CHAPTER 11 / ANSI 308/309

ALARMS AS REQUIRED

CHAPTER 11 / ANSI 702

SIGNAGE AS REQUIRED

DOOR THRESHOLD/FLOOR TRANSITION

BEYOND ADVERTISING AGENCY

CHAPTER 11 / ANSI 703

CHAPTER 11 / ANSI 302 AS REQUIRED

COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES COMPLIES EXISTING BUILDING EXISTING BUILDING EXISTING BUILDING

CLEAR FLOOR SPACE

SIGNAGE

BEYOND ADVERTISING AGENCY

1 Level 6 Existing

3/32" = 1'-0"

BEYOND ADVERTISING AGENCY

WALL DEMO
WALL DEMO

3/32" = 1'-0" 1 Level 7 Existing

BEYOND ADVERTISING AGENCY

BEYOND ADVERTISING AGENCY

BEYOND ADVERTISING AGENCY

BEYOND ADVERTISING AGENCY

BEYOND ADVERTISING AGENCY

BEYOND

Transverse Section Facing East

3/32" = 1'-0" 2 Longitudinal Section Facing North 3/32" = 1'-0"

Brand Pop-Up Existing Plan Callout

1/4" = 1'-0"

BEYOND ADVERTISING AGENCY

EXISTING CONCRETE FINISH

LIGHTING SECURED TO SURROUNDING BEAMS

EXISTING CONCRETE STRUCTURAL COLUMN

REQUIRED STRUCTURAL BEAMCONCRETE ENCASED STEEL BEAM

OPENINGS IN FLOOR SLAB

BEYOND ADVERTISING AGENCY

PRECAST CONCRETE STAIRCASE REF: A403-1

TRANSVERSE STEEL REINFORCEMENT

PRECAST CONCRETE STAIR RISER AND TREAD

BOTTOM STAIR SLAB LONGITUDINAL STEEL REINFORCEMENT TOP STAIR SLAB LONGITUDINAL STEEL REINFORCEMENT

EMT CONDUIT

THREADED COMPRESSION EMT FITTING

CAST BOX WITH 1/2" THREADED HUB NEOPRENE GASKETING GFI

BEYOND ADVERTISING AGENCY

Stair Axon

EXPERIENCE:

CORK

BEYOND ADVERTISING AGENCY

RECCESSED LIGHTING INTEGRATED INTO POP-UP "TREES"

FABRIC SUSPENDED FROM METAL GRILL, REFER TO A415 -1

PENDANT LIGHTS SUSPENDED THROUGH METAL GRID

TRANSLUCENT SUSPENDED FABRIC REFERENCE: A414-4

INTERACTIVE "TREE" CYLINDERS

ILLUMINATED PENDANT LIGHTING

BEYOND ADVERTISING AGENCY

EXISTING CONRETE CEILING FINISH ABOVE

SATIN PAINT FINISH BASED ON INSTALLATION: SPEC: SHERWIN WILLIAMS - SW 6774 EVERGREEN

METAL GRILL SUSPENSION HEIGHT RETAIL GWB CEILING HEIGHT

MAPLE WOOD VENEER

Pop-Up Display Elevation

= 1'-0"

LASER CUT PLYWOOD LETTERING, SANDED NO FINISH

SHERWIN WILLIAMSSW 6774 EVERGREEN

Pop-Up "Tree" Cylinder Elevation

- 3" 3 LAYERS OF 3/8" MOLDED/CURVED PLYWOOD

BEYOND ADVERTISING AGENCY

GWB CEILING

SUSPENDED METAL GRILL

SUSPENDED PENDANT LIGHITING

WOOD WITH WOOD VENEER' BUILT-IN RECESSED LIGHTING

BEYOND ADVERTISING AGENCY

2"

8

Brushed Stainless Steel Passage Set

Brushed Stainless Steel Privacy Set/Interior Lock

Brushed Stainless Steel Privacy Set/Interior Lock

Brushed Stainless Steel Privacy Set/Interior Lock

Brushed Stainless Steel Privacy Set/Interior Lock

Brushed Stainless Steel Vertical Handle Passage Set

Brushed Stainless Steel Vertical Handle Passage Set

Brushed Stainless Steel Passage Set

Brushed Stainless Steel Passage Set

Brushed Stainless Steel Passage Set

Brushed Stainless Steel Passage Set

Brushed Stainless Steel Passage Set

Brushed Stainless Steel Passage Set

Brushed Stainless Steel Sliding Door Handle As Specified by Manufacturer

Sliding Glass Door on Track with Glass Paneling Surround

BEYOND ADVERTISING AGENCY

BEYOND ADVERTISING AGENCY

BEYOND ADVERTISING AGENCY

ROOM NAME

LOBBY

PRIVACY POD/PHONE

TEAM MEETING WELLNESS

LACTATION

HUDDLE

PRIVATE OFFICE

OPEN OFFICE

WORK CAFE/MULTI PURPOSE

BRAND RETAIL POP-UP CORRIDORS

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HEAT/COOL

HVAC SUPPLY SPACES

PARTIALLY ENCLOSED

SINGLE SLIDING DOOR & CURTAIN WALL SINGLE DOOR

SINGLE SLIDING DOOR

SINGLE SLIDING DOOR

MEDIUM NATURAL LIGHT

MEDIUM NATURAL LIGHT

HIGH NATURAL LIGHT

NO NATURAL LIGHT

NO NATURAL LIGHT

MEDIUM NATURAL LIGHT

MEDIUM NATURAL LIGHT

HIGH NATURAL LIGHT

HIGH NATURAL LIGHT

HIGH NATURAL LIGHT

VARIOUS

MULTI-ZONE SYSTEM

MULTI-ZONE SYSTEM

MULTI-ZONE SYSTEM

MULTI-ZONE SYSTEM

MULTI-ZONE SYSTEM

MULTI-ZONE SYSTEM

MULTI-ZONE SYSTEM

GENERAL NOTES HVAC SECTION LEGEND

The decisions for the placement of the HVAC systems correlates to the placement of the users within the space as well as the proposed lighting design. Supply was strategically placed in each space needing cooling and heating, but never directly over a desk or long term seating area for user comfort. Returns are only placed in enclosed spaces and the kitchen/food prep areas where air needs increased circulation. Each diffuser is placed on the ceiling plane in a way that it will not interupt the electric and lighting design elements. The condition of abundant fenestration from exterior windows lining the space means increased natural light and therefore, heat. This was also taken into consideration with placement of supplies around those areas.

HVAC specialists, contractors, architects, and lighting designers would collaborate to successfully coordinate these systems to be the most efficient.