HLD Plastic anchors Economical plastic anchor for drywall Anchor version
Benefits - Plastic undercut anchor - Simple setting HLD (M10)
- Drywall application
Base material
Drywall
Basic loading data All data in this section applies to: Correct setting (See setting instruction) No edge distance and spacing influence Base material as specified in the table Load data given in the tables is independent of load direction
Characteristic resistance Anchor size Anchoring principle Gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 2x12,5mm Hollow clay brick Concrete ≥ C16/20 a)
HLD 4
FRk
[kN]
0,4
0,4
0,4
A
FRk
[kN]
0,3
-
-
A
FRk
[kN]
-
0,6
-
A/B C
FRk FRk
[kN] [kN]
0,75 1,25
0,75 2
2,5
HLD 2
HLD 3
HLD 4
See setting details
Anchoring principle Gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 12,5mm Fibre reinforced gypsum board Thickness 2x12,5mm Hollow clay brick Concrete ≥ C16/20
1
HLD 3
B
Design resistance Anchor size
a)
HLD 2 a)
a)
B
FRd
[kN]
0,11
0,11
0,11
A
FRd
[kN]
0,08
-
-
A
FRd
[kN]
-
0,17
-
A/B C
FRd FRd
[kN] [kN]
0,21 0,35
0,21 0,56
0,70
See setting detail
Updated: Dec-17