A2L Compatible Line Up

Page 1

The HVACR industry is making the transition to more environmentally friendly (lower GWP) refrigerants. With this transition, HFCs are being phased down and there has been a growing acceptance of the use of A2L refrigerants due to their lower flammability and toxicity.

Just like A1 refrigerants, some A2L refrigerants are blends and some are pure. Here are a few A2L refrigerants and what HFCs refrigerants they replace. Please refer to flammable refrigerant safety guides, regional codes and legislation for more information about handling these refrigerants.

Fieldpiece has you covered. Pick up your A2L compatible tool today.

Conditioning Contractors of America
Safety Group Higher Flammability A3 B3 Flammable A2 B2 Lower Flammability A2L B2L No Flame Propagation A1 B1 Lower Toxicity Higher Toxicity I N C R E A S I N G F L A M M A B I L I T Y INCREASING TOXICITY
Air
https://hvac-blog.acca.org/staying-frosty-with-a2l-refrigerants/
Fieldpiece Instruments Inc. 1636 West Collins Ave Orange, CA 92867 www.fieldpiece.com © Fieldpiece Instruments Inc. 2023, v16 HFCs Refrigerants Global Warming Potential (AR4 - 100 YR.) A2L Replacements Global Warming Potential (AR4 - 100 YR.) R-134a 1,430 R-123yf 4 R-123ZE (E) 7 R-516a 128 R-22 / R-404A 1,810 / 3,922 R-454A 239 R-454C 148 R-410A 2,088 R-32 675 R-454B 466
DEFINING A2L A2L REFRIGERANT REPLACEMENT

PLATINUM BEAST

DV-340N 12 CFM Vacuum Pump

Made in the USA

F6-BOOST

BLDC Ignition-Proof Refrigerant Recovery Machine

Provides over 20% faster vapor recovery rates than the competition

A2L Gauges

M2-861 Compound/ M2-862 Pressure

A2L refrigerants, R32 and R454B, with 410A

3-1/8" Illuminating, Class 1, 1% metal gauges with high impact clear view Lexan lens

Made in the USA

PLATINUM DC 8.4

DV-240DC 8.4 CFM Vacuum Pump

The DC motor pump is tough, versatile, and powerful enough to pull a deep vacuum on virtually any size system

Made in the USA

A2L PRODUCTS

ELIMINATOR DC 6E

DV-6EDC 6 CFM Vacuum Pump

Made in the USA

F6-DP Refrigerant Recovery Machine

Full one horsepower motor and powerful dual piston compressor

PATRIOT 22633

Rugged 2-Valve Manifold

A2L Gauges and KOBRA CCLE-60" Hose Set

Made in the USA

PLATINUM/ ELMINATOR

Spark-Proof Pumps

LD-5000 PROWLER & LD-3000 QUEST

Electrochemical Refrigerant

Leak Detectors

Detect all HFC, HCFC, HFO and blended refrigerants

Spark-proof, dual voltage motor with switch and removable, interchangeable power cord

Made in the USA

A2L Reverse Thread Adapters

QC-A2L-LH Left-handed ¼" female flare x ¼" male flare to be used for non-automotive A2L applications such as R454B/R32 tanks

QC-1234-LH Left-handed thread ½" ACME for automotive

Made in the USA

JB INDUSTRIES 800.323.0811 JBIND.COM SALES@JBIND.COM
0423
MOTOR DC MOTOR DC MOTOR
DC

RITCHIE ENGINEERING - YELLOW JACKET®

A2L Compatible Products

Vacuum Pumps:

p/n 93740 SuperEvac® PLUS II 4 CFM

p/n 93760 SuperEvac® PLUS II 6 CFM

p/n 93780 SuperEvac® PLUS II 8 CFM

p/n 93870 BULLET®DC 7 CFM

Leak Detectors:

p/n 69320 AccuProbe™ IR Leak Detector

Series 41 Manifolds w/ Digital Gauges:

p/n 46060 Series 41 Manifold with Digital Gauges

p/n 46062 Series 41 Manifold with Digital Gauges w/ hoses

p/n 49017 Digital Replacement Gauge

P51 TITAN® Digital Manifolds:

p/n 40860 P51-860 TITAN® Digital Manifold Kit

p/n 40870 P51-870 TITAN® Digital Manifold Kit

p/n 40875 P51-870 TITAN® Digital Manifold Kit with 5/16" Ball Valve Hoses

p/n 40877 P51-870 TITAN® Digital Manifold Kit with 5/16" Ball Valve Hoses and YJACK™ Clamps

YJACK™ Wireless BLE HVAC Sensors:

p/n 67063 YJACK DEW™ Psychrometer

p/n 67060 YJACK PATH™ Range Extender

p/n 67061 YJACK™ Temperature Clamp

p/n 67062 YJACK™ Temperature Strap

p/n 67065 YJACK PRESS™ Pressure Gauge

p/n 67066 YJACK VAC™ Vacuum Gauge

p/n 67067 YJACK AMP™ Current Probe

YJACK™ Wireless BLE HVAC KITS:

p/n 67070 YJACK™ Temperature Clamp Kit

p/n 67071 YJACK™ Temperature/Humidity Ki

p/n 67072 YJACK™ Charging Kit

p/n 67073 YJACK™ Charging & Air Kit

p/n 67074 YJACK™ Charging & Evacuation Kit

*ALL Series 41 and TITAN™ Analog R32/410A Manifolds and Gauges

A2L, What You Need To Know

Specific tools that can be certified to service A2L equipment are recovery machines, vacuum pumps, and leak detectors.

The UEi RLD15B Refrigerant Leak Detector is “A2L Certified” to the SAE 2913 standard, which includes “Component Ignition Testing”, that meets the A2L Certification.

UEi’s other Refrigeration products outside that product category are designed to work with equipment using A2L refrigerants and categorized as “A2L Compatible”.

Refrigerant Leak Detector

RLD15B

UPC: 053533507430

Refrigerant Leak Detector

w/ Solid Electrolyte Sensor

• A2L certified (SAE J2913)

• 3 Sensitivity levels

• Digital numeric leak size indicator

• 2-Year limited warranty

The HUB Wireless Refrigeration Probes

HUB8 053533508598

Smart Refrigeration Probes Deluxe Kit

• 1 Wireless vacuum gauge probe

• 1 Wireless outdoor temperature probe

• 2 Wireless hygrometer probes

• 2 Wireless pressure probes

• 2 Wireless pipe clamp probes

HUB6 053533508246

Smart Refrigerant Complete Kit • 2 Wireless hygrometers

2 Wireless pressure probes

2 Wireless pipe clamps

HUB4 053533508239

Smart Refrigerant Charging Kit

2 Wireless pressure probes

clamps

WVG2 053533508604

Wireless Vacuum Gauge Probe

WOT2 053533508611

Wireless Outside Temperature Probe

Refrigeration Scales & Refrigeration Test Instruments

WRS110

UPC: 053533507584

WRS220

UPC: 053533507577

Wireless Charging Scale 220lb

Wireless Charging Scale 110lb DMG150

WRSX

UPC: 053533581195

Wireless Charging Scale 330lb w/ Display

UPC: 053533507720

Digital Vacuum Micron Gauge

RLD10

UPC: 053533503937

Refrigerant Leak Detector

HA1

UPC: 053533500752

Hermetic Compressor Analyzer

A2L
UEiTEST.COM • 1-800-547-5740 • SALES@UEITEST.COM Copyright ©2023 KANE USA, Inc. All rights reserved. L758 11/23
Refrigerant Product Guide
2 Wireless pipe
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.