MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.
ADDITION TO (E) S.F.D. R.F.A. =460
B. AREA
15'-7"
SMART IRRIGATION CONTROLLER
PORTION OF (E) S.F.D. TO BE ADDED TO (N) A.D.U. R.F.A. =154
TO BE REMODELED "NO EXISTING FIRE-SPRINKLER SYSTEM" (E) GARAGE TO BE CONVERTED TO (N) A.D.U. R.F.A.
AREA=251
LEGAL DESCRIPTION
Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail:
PROJECT ANALYSIS
Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 6128-6130 Case avenue, North Hollywood, Ca 91606
RESIDENTAIL FLOOR AREA
MAX. ALLOWED R.F.A. =
R.F.A.
X
+75
2,699.14
EXISTING ROOF PLAN
KITCHEN TO BE RELOCATED TO (N)
EXISTING FLOOR PLAN
M CAD
SERVICESL
LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com
MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.
Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606
Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U.
construction
F. MEANS OF EGRESS
1.Provide emergency egress from sleeping rooms and basement. Show details on plans. Required minimum dimensions are 24" clear height, 20" clear width, 5.7 sq. ft. (5.0 sq. ft. at grade level) and 44" max to bottom of opening.(1030.2, R310.2)
not be
ten feet of any power lines-whether or not the lines are located on the property.
to comply may cause construction
and/or additional
b. An approved Seismic Gas Shutoff Valve will be installed on the fuel gas line on the downstream side of the utility meter and be rigidly connected to the exterior of the building or structure containing the fuel gas piping. (Per Ordinance 170,158) (Separate plumbing permit is required).
c. Plumbing fixtures are required to be connected to a sanitary sewer or to an approved sewage disposal system (R306.3).
d. Kitchen sinks, lavatories, bathtubs, showers, bidets, laundry tubs and washing machine outlets shall be provided with hot and cold water and connected to an approved water supply (R306.4).
e. Bathtub and shower floors, walls above bathtubs with a showerhead, and shower compartments shall be finished with a nonabsorbent surface. Such wall surfaces shall extend to a height of not less than 6 feet above the floor (R307.2).
f. Provide ultra-low flush water closets for all new construction. Existing shower heads and toilets must be adapted for low water consumption.
g. Unit Skylights shall be labeled by a LA City Approved Labeling Agency. Such label shall state the approved labeling agency name, product designation and performance grade rating. (Research Report not required). (R308.6.9)
h. Water heater must be strapped to wall. (Sec. 507.3, LAPC)
l. Smoke detectors shall be provided for all dwelling units intended for human occupancy, upon the owner's application for a permit for alterations, repairs, or additions, exceeding one thousand dollars ($1,000). (R314.6.2)
m. Where a permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel-burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.2. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. (R315.2.2)
n. Every space intended for human occupancy shall be provided with natural light by means of exterior glazed openings in accordance with Section R303.1 or shall be provided with artificial light that is adequate to provide an average illumination of 6 foot-candles over the area of the room at a height of 30 inches above the floor level. (R303.1)
o. A copy of the evaluation report and/or conditions of listing shall be made available at the job site
p. Heater shall be capable of maintaining a minimum room temperature of 68°f at a point 3 feet above the floor and 2 feet from exterior walls in all habitable rooms at the design temperature. (r303.9)
D. FIRE-RESISTANCE RATED CONSTRUCTION
1.Provide 1-hr fire-resistance rating for exterior walls for R-3 and/or U occupancy less than 5' from property line or assumed property line. (Table 602, 706.1.1, & 706.4, R302.1) (1207)
2.Projections beyond exterior walls shall not extend any closer to the line used to determine the fire separation distance than shown in (Table 705.2) (Table R302.1(1)) (Table R302.1(2)). (705.2, R302.1)
E. FIRE PROTECTION
1. Smoke detectors shall be provided in each sleeping room, on the ceiling or wall immediately outside of each sleeping room, and on each story and basement for dwellings with more than one story. (907.2.11.2, R314.3)
2.The power source for smoke detectors shall be as follows:
a. In new construction smoke detectors shall receive their primary power from the building wiring and shall be equipped with a battery backup. (907.2.11.4, R314.4)
b. In existing SFD, smoke detectors may be battery operated. (907.2.11.6, R314.4)
3. Carbon monoxide alarm is required per 420.4 & R315.
4. Sprinkler system shall be required for the ADU if the existing dwelling has a sprinkler system.
2.Landing at a door shall have a length measured in the direction of travel of no less than (36") (44"). (1008.1.6, R311.3)
3.Provide 42" high guards with less than 4" spacing opening between rails. For R-3 occupancies and within individual units in R-2 occupancies, guards whose top rail also serves as a handrail shall have a height between 34" to 38" measured vertically from the leading edge of the stair nosing tread. (1015.3 & 1015.4, R312.1)
LIGHTING MEASURES:
A. Kitchens. All luminaries in kitchens shall be high efficacy.
B. Lighting in Garages, Laundry Rooms and Utility Rooms. All luminaries shall be high efficacy and shall be controlled by a vacancy sensor.
C. Other Rooms. All luminaries shall either be high efficacy and shall be controlled by a vacancy sensor or dimmer. Closets that are less than 70 square foot are exempt from this requirement.
D. Outdoor Lighting. All luminaries mounted to the building or to other buildings on the same lot shall be high efficacy luminaries and shall be controlled by a photocontrol/motion sensor combination (with override). See IS0(k)9 for requirements.
· Lighting in bathrooms shall have at least 1 luminaries controlled by vacancy sensor.
· Exhaust fans shall be switched separately from lighting system.
· High efficacy luminaries must be pin based.
ELECTRICAL SYMBOLS
D A-5
H. BUILDING ENVELOPE
1.Provide a Class A, B or C fire-retardant cool roof labeled and certified by the CRRC. (1505.1 & Table 1505.1., R902.1, R327)
2.Glazing in hazardous locations shall be tempered (2406.4, R308.4):
a. Ingress and egress doors b. Panels in sliding or swinging doors c. Doors and enclosure for hot tub, bathtub, showers (Also glazing in wall enclosing these compartments within 5' of standing surface)
d. If within 2' of vertical edge of closed door and within 5' of standing surface e. In wall enclosing stairway landing f. Guards and handrails
4. Window sill of openable windows more than 72 inches above finished grade or other surface below shall not be less than 24/42 inches from finished floor of the room it is located in. (1015.1, R312.2.1)
5. Details of the guards at the floor and roof openings, occupied roofs and balconies or porches more than 30" above grade are required. Guards shall be 42" in height, have intermediate rails or balusters spaced at 4" maximum and be designed for (50 lbs/ft) (20 lbs/ft) (200 lb. concentrated) lateral load. (1015.3 & 1607.8.1, 2407, R312.1)
GREEN BUILDING NOTES
Each appliance provided and installed meets ENERGY STAR if an ENERGY STAR designation is applicable for that appliance.
Newly installed bathroom exhaust fans shall be ENERGY STAR compliant and be ducted to terminate to the outside of the building. Provide the manufacturer’s cut sheet for verification. (4.506.1, 9.506.1)
Newly installed bathroom exhaust fans, not functioning as a component of a whole house ventilation system, must be controlled by a humidistat which shall be readily accessible.
DESCRIPTIONSYMBOL
SD SMOKE DETECTOR HARDWIRED,INTERCONNECTED W/ BATTERY BACK-UP. 120 V
CO CARBON MONOXIDE DETECTOR (INTERCONECTED TO SMOKE ALARMS)
EXHAUST FAN. 50 CFM (ENERGY STAR, HUMID STAT)EF
LAUNDRY ROOM
A MIN. 4" EXHAUST DUCT MUST BE PROVIDED. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6' AND CANNOT BE CONCEALED. DRYER EXHAUST CANNOT EXCEED 14' W/ MAX OF TWO 90° ELBOWS.
All branch circuits that supply 125 volt, single phase, 15 and 20 ampere outlets installed in dwelling units shall be protected by an arc-fault circuit interrupter(s). (CEC 210.12) for entire circuit, not just the outlets.
MIN.
MIN. 24" MIN.
MIN.
TYPICAL TOILET CLEARANCE
M CAD SERVICESL
LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com
MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.
A-5
A-5
Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606
A-5
Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 11/30/2020
M CAD
SERVICES
LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com
MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.
ROOFING
PROVIDE
DOWNSPOUT
Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail:
Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U.
Case avenue, North Hollywood, Ca 91606
ABOVE PAVED AREAS. (CBC 2512.1.2)
NORTH(LEFT) ELEVATION
PROVIDE
A
M CAD SERVICESL
LUIS MAURICIO
9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com
EAST(REAR) ELEVATION
SCALE:
ROOFING MATERIAL BY:
(30 YRS ASPHALT SHIGNLES)
(CLASS
Antique Slate (gray)
MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.
PROVIDE (2) 24"X12" DIA. HALF ROUND DORMER VENTS
REQUIRED
SQIN PROPOSED >
OPENINGS SHALL HAVE 1/8" CORROSION
Building address shall be provided on the
the street.
with their background, 4" high
width of 0.5 (Section R319.1)
a
as to be plainly visible and legible
and with a
shall
SOUTH(RIGHT)
Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606
Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 11/30/2020
WEST(FRONT) ELEVATION
(E) FRAMING TO REMAIN
(E)
(E) LIVING (E) FLR FRAMING TO REMAIN
8'-0"
7 8 STUCCO (WHERE OCCURS) (N)2X4 STUD @ 16" O.C. (WHERE OCCURS)
R-15 INSULATION
FRAMING
5'-0" A.L.G.
R-38 BATT INSULATION
(E)2X4 STUD @ 16" O.C. 18"
R-15 INSULATION
R-15 INSULATION
SECTION E
SCALE: 1/4":1'-0"
NG 5%
SECTION D
SCALE: 1/4":1'-0"
M CAD
SERVICESL
LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com
DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.
MC
12 4 (N) A.D.U. GREAT RM BEDROOMW/D BATHRM
(E) 4" CONCRETE SLAB W/ REDGUARD MOISTURE BARRIER
(E) RAISED FLOOR 9'-0"
SECTION C
8'-0"
SCALE: 1/4":1'-0"
7 8 STUCCO (E)2X4 STUD @ 16" O.C.
R-15 INSULATION
5'-0" A.L.G.
SECTION B
SCALE: 1/4":1'-0"
AREA CAVITY BATT INSULATION R-VALUE ROOF CEILING
WALL FLOOR
ATTIC C.J. PER PLAN = 1-HR FIRE RATED WALL
R-38 (PROVIDE RADIANT BARRIER FOR ROOF SHEATHING) R-15 N/A
0.05 emmitance min.
ROOF PLY 1/2" CDX PLYWOOD OR OSB SHEATING W/8d @ 6-6-12 O/C P.I. 32/16 (RADIANT BARRIER)
SECTION A
SCALE: 1/4":1'-0"
Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606
Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 11/30/2020