Gustavo Trochez-SAMPLE DRAWING SET

Page 1

DISCLAIMER

PUBLIC TRANSPORATION WITHIN 0.5 MILES

DESIGN CRITERIA

M CAD SERVICESL

LUIS MAURICIO

9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com

MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.

ADDITION TO (E) S.F.D. R.F.A. =460

B. AREA

15'-7"

SMART IRRIGATION CONTROLLER

PORTION OF (E) S.F.D. TO BE ADDED TO (N) A.D.U. R.F.A. =154

TO BE REMODELED "NO EXISTING FIRE-SPRINKLER SYSTEM" (E) GARAGE TO BE CONVERTED TO (N) A.D.U. R.F.A.

AREA=251

LEGAL DESCRIPTION

Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail:

PROJECT ANALYSIS

Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 6128-6130 Case avenue, North Hollywood, Ca 91606

RESIDENTAIL FLOOR AREA

MAX. ALLOWED R.F.A. =

R.F.A.

X

+75

2,699.14

Zoning R1-1 SCALE: 1/8":1-0" PROPOSED SITE PLAN ALL FRAMING CONNECTORS TO BE SIMPSON STRONG TIE OR EQUAL TIMBER: DOUGLAS FIR LARCH (PER GRADING RULES 16) 2X4 AND 4X4 STANDAR GRADE (VERTICAL MEMBERS) NO. 2 (HORIZONTAL MEMBERS) 2X6 AND LARGER NO. 2 GRADE (HORIZ. AND VERT. MEMBERS) 4X6 AND LARGER NO. 1 GRADE (HORIZ. AND VERT. MEMBERS) PLYWOOD PS-1-95 PER APA STANDARD. PL 32/16 STRENGTH @ 28 DAYS PER ACI 318 SPECIFICATIONS FOUNDATION : f'c=2500 psi CONCRETE NON CONTINUOUS INSPECTION REQUIRED SOIL: ALLOWABLE SOIL BEARNING VALUE (FBRG) = 1500psf. PER SOILS REPORT BY: CBC TABLE 1804.2
WRITTEN DIMENSIONS SHALL BE VERIFIED ON THE JOB SITE. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE DRAFTER PRIOR TO THE COMMENCEMENT OF ANY WORK.
(EXPANSIVE SOIL CONDITION) LARR#: 25744 (WITH CONDITIONS OF APPROVAL) EPOXY BOLTS LOT AREA: 5,998.1 SF EXISTING S.F.D. 1,000.0 SF EXISTING FRONT PORCH 75.0 SF R.F.A. BUILD. AREA EXISTING S.F.D. AREA 1,000 PROPOSED ADDITION TO S.F.D. 460 480 PORTION OF S.F.D. TO CONVERT TO AN A.D.U. -154 TOTAL S.F.D. AREA 1,306 SF GARAGE CONVERSION TO AN A.D.U. 231 251 CONVERSION OF S.F.D. TO A.D.U. 154 TOTAL A.D.U. AREA 385 SF APPLICABLE CODES: 2019 CALIFORNIA RESIDENTIAL BUILDING CODE, CMC, CEC & CPC 2019 CALIFORNIA ENERGY STANDARDS 2020 LOS ANGELES GREEN BUILDING CODE 2020 CITY OF LOS ANGELES BUILDING CODE Site Address 6130 N CASE AVE ZIP Code 91606 PIN Number 177B173 625 Lot/Parcel Area (Calculated) 2,999.1 (sq ft) Thomas Brothers Grid PAGE 533- GRID A7 Assessor Parcel No. (APN) 2336-035-019 Tract TR 5847 Map Reference M B 60-83/84 Block B Lot 37 & 38 Arb (Lot Cut Reference) None Map Sheet 177B173 25.00' CASE AVE. 25.00'25.00' 120.00'120.00' 25.00' (E) 1-STORY S.F.D. (E) COVERED PORCH 75 SF (E) DRIVEWAY (E) PLANTER (E) LANDSCAPING (E) WALKWAY (E) 6FT HIGH GATE (E) LANDSCAPING DOWNSPOUT 55 GAL RAIN BARREL TRIBUTARY ROOF AREA 1 = 346 SF TRIBUTARY ROOF AREA 2 = 346 SF TOTAL ROOF AREA= 692 SF PROVIDE (4) 55 GAL RAIN BARRELS PROVIDE (1) 15 GAL. SHADE TREE
=231 SQ FT B.
SF
SQ FT (N)
SF
=480 SF 20'-0" 5'-3" 24'-0" 20'-9" 31'-11"
5'-2" 51'-11" 30'-11" 37'-2" 5'-2"12'-1"32'-9" 5% 5% 5%5% 5% 5% 5% 5% 5% 5% 5% 5% 5% 5%
5998.1
0.45 =
SF PROPOSED
= 1306
+ 385 = 1,766.00 SF SCHOOL FEE AREA(S) = N/A (A.D.U < 750 SF, ADDITION <500 SF) 15 GAL SHADE TREE
DRAWN SHEET SCALE JOB NO. DATE OF SHEETS CHECKED BYREVISIONS A-1
11/30/2020

EXISTING ROOF PLAN

KITCHEN TO BE RELOCATED TO (N)

EXISTING FLOOR PLAN

M CAD

SERVICESL

LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com

MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.

Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606

Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U.

SCALE: 1/4"= 1'-0" 4:12 4:12
SCALE: 1/4"= 1'-0"= (E) WALL (2X4 WOOD STUD @ 16" O.C.) TO REMAIN = (E) WALL/WINDOW/DOOR (2X4 WOOD STUD @ 16" O.C.) TO REMOVE 2X4 4X3 4X3 3X3 GARAGE TO BE CONVERTED TO NEW A.D.U. (2) 3X6 COVERED PORCH SCREEN WALL LIVING BEDROOM BEDROOM CLOSET BATHROOM CL. 4X3 3X3 2X2 3X3 3X3 PONY WALL PONY WALL 4:12 4:12 CL.
ADDITION
DRAWN SHEET SCALE JOB NO. DATE OF SHEETS CHECKED BYREVISIONS A-2
11/30/2020

construction

F. MEANS OF EGRESS

1.Provide emergency egress from sleeping rooms and basement. Show details on plans. Required minimum dimensions are 24" clear height, 20" clear width, 5.7 sq. ft. (5.0 sq. ft. at grade level) and 44" max to bottom of opening.(1030.2, R310.2)

not be

ten feet of any power lines-whether or not the lines are located on the property.

to comply may cause construction

and/or additional

b. An approved Seismic Gas Shutoff Valve will be installed on the fuel gas line on the downstream side of the utility meter and be rigidly connected to the exterior of the building or structure containing the fuel gas piping. (Per Ordinance 170,158) (Separate plumbing permit is required).

c. Plumbing fixtures are required to be connected to a sanitary sewer or to an approved sewage disposal system (R306.3).

d. Kitchen sinks, lavatories, bathtubs, showers, bidets, laundry tubs and washing machine outlets shall be provided with hot and cold water and connected to an approved water supply (R306.4).

e. Bathtub and shower floors, walls above bathtubs with a showerhead, and shower compartments shall be finished with a nonabsorbent surface. Such wall surfaces shall extend to a height of not less than 6 feet above the floor (R307.2).

f. Provide ultra-low flush water closets for all new construction. Existing shower heads and toilets must be adapted for low water consumption.

g. Unit Skylights shall be labeled by a LA City Approved Labeling Agency. Such label shall state the approved labeling agency name, product designation and performance grade rating. (Research Report not required). (R308.6.9)

h. Water heater must be strapped to wall. (Sec. 507.3, LAPC)

l. Smoke detectors shall be provided for all dwelling units intended for human occupancy, upon the owner's application for a permit for alterations, repairs, or additions, exceeding one thousand dollars ($1,000). (R314.6.2)

m. Where a permit is required for alterations, repairs or additions exceeding one thousand dollars ($1,000), existing dwellings or sleeping units that have attached garages or fuel-burning appliances shall be provided with a carbon monoxide alarm in accordance with Section R315.2. Carbon monoxide alarms shall only be required in the specific dwelling unit or sleeping unit for which the permit was obtained. (R315.2.2)

n. Every space intended for human occupancy shall be provided with natural light by means of exterior glazed openings in accordance with Section R303.1 or shall be provided with artificial light that is adequate to provide an average illumination of 6 foot-candles over the area of the room at a height of 30 inches above the floor level. (R303.1)

o. A copy of the evaluation report and/or conditions of listing shall be made available at the job site

p. Heater shall be capable of maintaining a minimum room temperature of 68°f at a point 3 feet above the floor and 2 feet from exterior walls in all habitable rooms at the design temperature. (r303.9)

D. FIRE-RESISTANCE RATED CONSTRUCTION

1.Provide 1-hr fire-resistance rating for exterior walls for R-3 and/or U occupancy less than 5' from property line or assumed property line. (Table 602, 706.1.1, & 706.4, R302.1) (1207)

2.Projections beyond exterior walls shall not extend any closer to the line used to determine the fire separation distance than shown in (Table 705.2) (Table R302.1(1)) (Table R302.1(2)). (705.2, R302.1)

E. FIRE PROTECTION

1. Smoke detectors shall be provided in each sleeping room, on the ceiling or wall immediately outside of each sleeping room, and on each story and basement for dwellings with more than one story. (907.2.11.2, R314.3)

2.The power source for smoke detectors shall be as follows:

a. In new construction smoke detectors shall receive their primary power from the building wiring and shall be equipped with a battery backup. (907.2.11.4, R314.4)

b. In existing SFD, smoke detectors may be battery operated. (907.2.11.6, R314.4)

3. Carbon monoxide alarm is required per 420.4 & R315.

4. Sprinkler system shall be required for the ADU if the existing dwelling has a sprinkler system.

2.Landing at a door shall have a length measured in the direction of travel of no less than (36") (44"). (1008.1.6, R311.3)

3.Provide 42" high guards with less than 4" spacing opening between rails. For R-3 occupancies and within individual units in R-2 occupancies, guards whose top rail also serves as a handrail shall have a height between 34" to 38" measured vertically from the leading edge of the stair nosing tread. (1015.3 & 1015.4, R312.1)

LIGHTING MEASURES:

A. Kitchens. All luminaries in kitchens shall be high efficacy.

B. Lighting in Garages, Laundry Rooms and Utility Rooms. All luminaries shall be high efficacy and shall be controlled by a vacancy sensor.

C. Other Rooms. All luminaries shall either be high efficacy and shall be controlled by a vacancy sensor or dimmer. Closets that are less than 70 square foot are exempt from this requirement.

D. Outdoor Lighting. All luminaries mounted to the building or to other buildings on the same lot shall be high efficacy luminaries and shall be controlled by a photocontrol/motion sensor combination (with override). See IS0(k)9 for requirements.

· Lighting in bathrooms shall have at least 1 luminaries controlled by vacancy sensor.

· Exhaust fans shall be switched separately from lighting system.

· High efficacy luminaries must be pin based.

ELECTRICAL SYMBOLS

D A-5

H. BUILDING ENVELOPE

1.Provide a Class A, B or C fire-retardant cool roof labeled and certified by the CRRC. (1505.1 & Table 1505.1., R902.1, R327)

2.Glazing in hazardous locations shall be tempered (2406.4, R308.4):

a. Ingress and egress doors b. Panels in sliding or swinging doors c. Doors and enclosure for hot tub, bathtub, showers (Also glazing in wall enclosing these compartments within 5' of standing surface)

d. If within 2' of vertical edge of closed door and within 5' of standing surface e. In wall enclosing stairway landing f. Guards and handrails

4. Window sill of openable windows more than 72 inches above finished grade or other surface below shall not be less than 24/42 inches from finished floor of the room it is located in. (1015.1, R312.2.1)

5. Details of the guards at the floor and roof openings, occupied roofs and balconies or porches more than 30" above grade are required. Guards shall be 42" in height, have intermediate rails or balusters spaced at 4" maximum and be designed for (50 lbs/ft) (20 lbs/ft) (200 lb. concentrated) lateral load. (1015.3 & 1607.8.1, 2407, R312.1)

GREEN BUILDING NOTES

Each appliance provided and installed meets ENERGY STAR if an ENERGY STAR designation is applicable for that appliance.

Newly installed bathroom exhaust fans shall be ENERGY STAR compliant and be ducted to terminate to the outside of the building. Provide the manufacturer’s cut sheet for verification. (4.506.1, 9.506.1)

Newly installed bathroom exhaust fans, not functioning as a component of a whole house ventilation system, must be controlled by a humidistat which shall be readily accessible.

DESCRIPTIONSYMBOL

SD SMOKE DETECTOR HARDWIRED,INTERCONNECTED W/ BATTERY BACK-UP. 120 V

CO CARBON MONOXIDE DETECTOR (INTERCONECTED TO SMOKE ALARMS)

EXHAUST FAN. 50 CFM (ENERGY STAR, HUMID STAT)EF

LAUNDRY ROOM

A MIN. 4" EXHAUST DUCT MUST BE PROVIDED. A FLEXIBLE DUCT CANNOT EXTEND MORE THAN 6' AND CANNOT BE CONCEALED. DRYER EXHAUST CANNOT EXCEED 14' W/ MAX OF TWO 90° ELBOWS.

All branch circuits that supply 125 volt, single phase, 15 and 20 ampere outlets installed in dwelling units shall be protected by an arc-fault circuit interrupter(s). (CEC 210.12) for entire circuit, not just the outlets.

MIN.

MIN. 24" MIN.

MIN.

TYPICAL TOILET CLEARANCE

M CAD SERVICESL

LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com

MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.

A-5

A-5

Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606

A-5

Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 11/30/2020

EXISTING FLOOR PLAN SCALE: 1/4"= 1'-0" (2) 3X6 COVERED PORCH (E) SCREEN WALL LIVING BEDROOM BEDROOM CLOSET BATHROOM CL. 4X3 11'-3" GREAT RM 5'-0" 14'-0" 20'-0" 11'-4" BATHROOM CLOSET KITCHEN 14'-1" 5'-0" BEDROOM 7'-8" 4'-8" W/D BATHRM CL. 4'-0" 5'-4" 2'-0" 12'-9" 15'-2" 3'-0" 3'-1" 5'-0" 2'-11" 11'-10" 24'-0" 7'-9" 3'-6" 11'-4" BEDROOM DINING W/D 5'-6"5'-4" 2'-6" 9'-11" 2'-8" 5'-0" 7'-10" 3'-0" GENERAL REQUIREMENTS a. The construction shall not restrict a five-foot clear and unobstructed access to any water or power distribution facilities (Power poles, pull-boxes, transformers, vaults, pumps, valves, meters, appurtenances, etc.) or to the location of the hook-up. The
shall
within
Failure
delays
expenses.
15"
15"
30"
WINDOWS AND DOORS SCHEDULE SIZE DESCRIPTIONSYMBOL U-FACTOR SGHC 4'-0" x 5'-0"A 0.320 0.25 1 NOTE: ALL DOORS AND WINDOWS ARE DUAL GLAZED. 2 36"x80" HOLLOW CORE DOOR B 0.320 0.25 32"x80" SOLID CORE DOOR VINYL FRAME HORIZONTAL SLIDING WINDOW 1 VINYL FRAME HORIZONTAL SLIDING WINDOW = (E) WALL (2X4 WOOD STUD @ 16" O.C.) TO REMAIN = (N) WALL (2X4 WOOD STUD @ 16" O.C.) = (E) WALL (2X4 WOOD STUD @ 16" O.C.) TO REMOVE = 1-HR FIRE RATED WALL 3 SLIDING PATIO DOOR (TEMPERED)72"x80" C 0.320 0.25VINYL FRAME HORIZONTAL SLIDING WINDOW 4 60"x80" SLIDING CLOSET DOOR D 0.320 0.25VINYL FRAME HORIZONTAL SLIDING WINDOW (TEMPERED)6'-0" x 3'-0" G. INTERIOR ENVIRONMENT 1.Required ceiling height is 7'-6", 7'-0" min., 7'-0" min. in kitchen, bathrooms, laundry rooms and storage rooms. (1208.2, R305.1) 5.Provide 15" min between center line of water closet to any side wall or obstruction and 24" clear space in front of water closet. (LAPC 407.5) 7.Provide (20") (22") x 30" min. attic access, clearance and ventilation. Attic ventilation shall be not less than 1/150 of attic area. (1203.2 & 1209.2, R807.1) 8.In residential buildings, every interior door through which occupants pass shall have a minimum width of 32". (6304.1) E 0.320 0.255'-0" x 2'-0" 11'-1" 14'-9" 14'-10" Ø2'-6" Ø2'-6" SD EF CO SD Ø2'-6" EF SD SD CO SD CO SDSD EF EF 1 3'-0" MIN. 4'-0" 1.5" 7.75" MAX 7.75" MAX 2 EF 2 2 2 2 1 1.5" 7.75" MAX 7'-0"3'-0" MIN. 1.5" 7.75" MAX 3 TEMPERED 4 5 5 48"x80" SLIDING CLOSET DOOR 3'-0" A B 2'-0" x 2'-0" 14'-1" 9'-9" C 3'-0" x 4'-0" D TEMPERED E VINYL FRAME HORIZONTAL SLIDING WINDOW F F 0.320 0.253'-0" x 5'-0" VINYL FRAME SINGLE-HUNG WINDOW G F G 0.320 0.254'-0" x 4'-0" VINYL FRAME HORIZONTAL SLIDING WINDOW A-3 1 4'-0" 4'-0" (36" MIN.) C A-6 B
A
22"X30" ATTIC ACCESS EGRESS E
SEE ASSOCIATED NOTES ON SHEET A-6 H 0.320 0.253-0" 2'-0" VINYL FRAME HORIZONTAL SLIDING WINDOW (TEMPERED) H TEMP. C
DRAWN SHEET SCALE JOB NO. DATE OF SHEETS CHECKED BYREVISIONS A-3

M CAD

SERVICES

LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com

MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.

ROOFING

PROVIDE

DOWNSPOUT

Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail:

Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U.

Case avenue, North Hollywood, Ca 91606

EXISTING ROOF PLAN SCALE: 1/4"= 1'-0" 4:12 4:12 4:12 4:12 3:12 3:12 =NEW ROOF AREA 26'-0" 33'-1" 20'-1" 13'-0" 20'-1" OPENINGS SHALL HAVE 1/8" CORROSION 555.6 SQIN PROPOSED > 460.80 SQIN REQUIRED PROVIDE (2) 24"X12" DIA. HALF ROUND DORMER VENTS =228 SQIN114 SQIN EA. RESISTANT METAL MESH COVERING. ATTIC VENTILATION (ADDITION TO S.F.D.) (4) 14"X6" VENT. = 201.6 SQIN50.4 SQIN.EA. PROVIDE (1) 14" x18" TOP GABLE LOUVRE = 126 SQIN126 SQIN EA 480 SQFT /150 = 3.2 SQFT X (144 SQ.IN.) = 460.80 SQIN OPENINGS SHALL HAVE 1/8" CORROSION 428.4 SQIN PROPOSED > 400.32 SQIN REQUIRED RESISTANT METAL MESH COVERING. ATTIC VENTILATION (A.D.U.) (6) 14"X6" VENT. = 302.4 SQIN50.4 SQIN.EA. PROVIDE (2) 14" x18" TOP GABLE LOUVRE = 126 SQIN126 SQIN EA 417 SQFT /150 = 2.78 SQFT X (144 SQ.IN.) = 400.32 SQIN
55 GAL RAIN BARREL TRIBUTARY ROOF AREA 1 = 346 SF TRIBUTARY ROOF AREA 2 = 346 SF TOTAL ROOF AREA= 692 SF
(4) 55 GAL RAIN BARRELS PROVIDE (1) 15 GAL. SHADE TREE
MATERIAL BY: GAF (30 YRS ASPHALT SHIGNLES) ESR-1475 (CLASS A) Timberline Cool Antique Slate (gray) INITIAL SRI: 29, 3-YR SRI: 22 TRIBUTARY AREA 1= 346 SF TRIBUTARY AREA 2= 346 SF 13'-0"13'-0"
DRAWN SHEET SCALE JOB NO. DATE OF SHEETS CHECKED BYREVISIONS A-4
L
6130 CASE AVENUE 4-55 GAL A-4 A-5 1 A-1 11/30/2020
6128-6130

ABOVE PAVED AREAS. (CBC 2512.1.2)

NORTH(LEFT) ELEVATION

PROVIDE

A

M CAD SERVICESL

LUIS MAURICIO

9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com

EAST(REAR) ELEVATION

SCALE:

ROOFING MATERIAL BY:

(30 YRS ASPHALT SHIGNLES)

(CLASS

Antique Slate (gray)

MC DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.

PROVIDE (2) 24"X12" DIA. HALF ROUND DORMER VENTS

REQUIRED

SQIN PROPOSED >

OPENINGS SHALL HAVE 1/8" CORROSION

Building address shall be provided on the

the street.

with their background, 4" high

width of 0.5 (Section R319.1)

a

as to be plainly visible and legible

and with a

shall

SOUTH(RIGHT)

Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606

Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 11/30/2020

WEST(FRONT) ELEVATION

5'-0" A.L.G. N.G. 6'-8" F.F. 6'-8" (N) 7 8 STUCCO TO MATCH (E) F.F. 5'-0" A.L.G. N.G. (E) STUCCO TO REMAIN (E) STUCCO TO REMAIN N.G.N.G. (E) (N) (N) 7 8 STUCCO TO MATCH (E) 6'-8" 7.75" MAX 6'-8" 44" MAX 6'-8" (E) STUCCO TO REMAIN (N) 7 8 STUCCO TO MATCH (E) F.F. (E) ROOF TO REMAIN 15'-8" EXISTING (E) STUCCO TO REMAIN 5'-0" A.L.G. 5'-0" A.L.G. 7.75" MAXF.F. 12 4 (N) ROOF TO MATCH (E) 13'-5" PROPOSED
SCALE: 1/4"= 1'-0" 6'-8"
ELEVATION SCALE: 1/4"= 1'-0" N.G. 5'-0" A.L.G. N.G. 5'-0" A.L.G. TEMPERED 6'-8" TEMPERED (E) (N) (N) 7 8 STUCCO TO MATCH (E) 12 3 (E) ROOF TO REMAIN (E) STUCCO TO REMAIN 15'-8" EXISTING13'-5" PROPOSED 7.75" MAX N.G. 5'-0" A.L.G. N.G. 5'-0" A.L.G. (E) (N) 12 4 6'-8" 44" MAX 15'-8" EXISTING (N) 7 8 STUCCO TO MATCH (E) 6'-8" N.G. N.G. (N) 7 8 STUCCO TO MATCH (E) (E) STUCCO TO REMAIN (N) ROOF TO MATCH (E) 13'-5" PROPOSED 15'-8" EXISTINGROOFING MATERIAL BY: GAF (30 YRS ASPHALT SHIGNLES) ESR-1475 (CLASS A) Timberline Cool Antique Slate (gray) INITIAL SRI: 29, 3-YR SRI: 22
CORROSION RESISTANT WEEP SCREED IS REQUIRED BELOW THE STUCCO A MIN OF 4" ABOVE EARTH OR 2" ABOVE PAVED AREA. WHERE STUCCO SIDING IS APPLIED OVER PLY SHEATING, GRADE "D" PAPER UNDER LATH SHALL BE PROVIDED. NO. 26 GALVANIZED SHEET GAGE WEEP SCREED WITH 3-1/2" FLANGE AT STUCCO SIDING PLACED A MINIMUM OF 4-INCHES ABOVE EARTH OR 2-INCHES
building in such
position
from
Address numbers
contrast
minimum
minimum stroke
555.6
460.80 SQIN
=228 SQIN114 SQIN EA. RESISTANT METAL MESH COVERING. ATTIC VENTILATION (ADDITION TO S.F.D.) (4) 14"X6" VENT. = 201.6 SQIN50.4 SQIN.EA.
(1) 14" x18" TOP GABLE LOUVRE = 126 SQIN126 SQIN EA 480 SQFT /150 = 3.2 SQFT X (144 SQ.IN.) = 460.80 SQIN OPENINGS SHALL HAVE 1/8" CORROSION 428.4 SQIN PROPOSED > 400.32 SQIN REQUIRED RESISTANT METAL MESH COVERING. ATTIC VENTILATION (A.D.U.) (6) 14"X6" VENT. = 302.4 SQIN50.4 SQIN.EA. PROVIDE (2) 14" x18" TOP GABLE LOUVRE = 126 SQIN126 SQIN EA 417 SQFT /150 = 2.78 SQFT (144 SQ.IN.) = 400.32 SQIN 511.0 SQIN > 499.2 SQIN REQUIRED CRAWL SPACE VENTILATION FOR 481 S.F. (1) 24"x18" VENTS = 259 SQIN . (5) 14"X6" VENT. = 252 SQIN . 259 SQIN. EA. 50.4 SQIN.EA. 480 SQFT /150 = 3.20 SQFT (144 SQ.IN.) = 460.8 SQIN
1/4"= 1'-0"
SCALE: 1/4"= 1'-0" 6'-8" TEMP.
GAF
ESR-1475
A) Timberline Cool
INITIAL SRI: 30, 3-YR SRI: 27 INITIAL T. E.: .92, 3-YR T.E.: .91 ROOFING MATERIAL BY: GAF (30 YRS ASPHALT SHIGNLES) ESR-1475 (CLASS A) Timberline Cool Antique Slate (gray) INITIAL SRI: 30, 3-YR SRI: 27 INITIAL T. E.: .92, 3-YR T.E.: .91
DRAWN SHEET SCALE JOB NO. DATE OF SHEETS CHECKED BYREVISIONS A-5

(E) FRAMING TO REMAIN

(E)

(E) LIVING (E) FLR FRAMING TO REMAIN

8'-0"

7 8 STUCCO (WHERE OCCURS) (N)2X4 STUD @ 16" O.C. (WHERE OCCURS)

R-15 INSULATION

FRAMING

5'-0" A.L.G.

R-38 BATT INSULATION

(E)2X4 STUD @ 16" O.C. 18"

R-15 INSULATION

R-15 INSULATION

SECTION E

SCALE: 1/4":1'-0"

NG 5%

SECTION D

SCALE: 1/4":1'-0"

M CAD

SERVICESL

LUIS MAURICIO 9819 Beachy Ave. Arleta, CA 91331 (818) 433-9805 / 590-3125 lmcadservices@gmail.com

DRAFTING SERVICES SHALL NOT BE RESPONSIBLE FOR COMPLETENESS OF DRAWINGS FOR BIDDING PURPOSES PRIOR TO ISSUANCE OF BUILDING PERMITS. THE DRAWING(S) ONLY AND CONFIDENTIAL DISCLOSURE THAT MAY NOT BE USED OR THIS DESIGN AND DRAWINGS ARE SUBMITTED AS RESTRICTIVE OF THE OWNER NOTED AT THE EXCLUSIVE SITE INDICATED IN AS DEFINED BY THE CALIFORNIA ADMINISTRATIVE CODE. THEY THESE DRAWINGS ARE COPYRIGHTED INSTRUMENTS OF SERVICE ARE OWNED BY LM CAD. THEY ARE FOR THE EXCLUSIVE USE REPRODUCED WITHOUT THE WRITTEN CONSENT OF MC. THIS DRAWING REPRESENTS A PRELIMINARY DESIGN UNTIL SUCH LEGAL DISCLAIMER TIME THE ARCHITECT HAS AFFIXED HIS SEAL AND SIGNATURE.

MC

12 4 (N) A.D.U. GREAT RM BEDROOMW/D BATHRM

(E) 4" CONCRETE SLAB W/ REDGUARD MOISTURE BARRIER

(E) RAISED FLOOR 9'-0"

SECTION C

8'-0"

SCALE: 1/4":1'-0"

7 8 STUCCO (E)2X4 STUD @ 16" O.C.

R-15 INSULATION

5'-0" A.L.G.

SECTION B

SCALE: 1/4":1'-0"

AREA CAVITY BATT INSULATION R-VALUE ROOF CEILING

WALL FLOOR

ATTIC C.J. PER PLAN = 1-HR FIRE RATED WALL

R-38 (PROVIDE RADIANT BARRIER FOR ROOF SHEATHING) R-15 N/A

0.05 emmitance min.

ROOF PLY 1/2" CDX PLYWOOD OR OSB SHEATING W/8d @ 6-6-12 O/C P.I. 32/16 (RADIANT BARRIER)

SECTION A

SCALE: 1/4":1'-0"

Owner: Stonefarm Enterprises 6130 Case Ave. North Hollywood, CA 91606 Phone #: 323-803-8243 E-mail: 6128-6130 Case avenue, North Hollywood, Ca 91606

Scope of Work: (E) S.F.D. to be Remodeled, (N) Addition to S.F.D., and (E) Attached Garage and Portion of S.F.D. to become (N) A.D.U. 11/30/2020

1'-6"
R-15 INSULATION (E)2X4 STUD @ 16" O.C. 18" (E) LIVING (E) FLR FRAMING TO REMAIN 8'-0" NG 5% (E) FRAMING TO REMAIN R-15 INSULATION (E) STUCCO (E)2X4 STUD @ 16" O.C. 1-HR FIRE AND STC 50 WALL 9'-0" CJ PER PLAN (E) FRAMING TO REMAIN (E) 4" CONCRETE SLAB W/ REDGUARD MOISTURE BARRIER (N) A.D.U.
R-15 INSULATION (N) 7 8 STUCCO R-15 INSULATION (N) 7 8 STUCCO (N)2X4 STUD @ 16" O.C. 1/2" CDX PLYWOOD SHEATING W/8d @ 6-6-12 O/C RR PER PLAN 12 3 18" FJ PER PLAN 8'-0" NG 5% NG 5% (N)2X4 STUD @ 16" O.C. R-38 BATT INSULATION CJ PER PLAN KITCHENBEDROOM
R-15 INSULATION (N) 7 8 STUCCO (N)2X4 STUD @ 16" O.C. 1/2" CDX PLYWOOD SHEATING W/8d @ 6-6-12 O/CRR PER PLAN 12 4 (N) BEDROOM FJ PER PLAN 8'-0" NG 5% (E)2X4 STUD @ 16" O.C. R-38 BATT INSULATION CJ PER PLAN FJ PER PLAN (E) FRAMING TO REMAIN (N) BEDROOM (N) CLOSET (E) (N)
(E)
(E)
TO REMAIN
NG
5% NG
5%
(N)
STUCCO (E)2X4 STUD @ 16" O.C. 1-HR FIRE AND STC 50 WALL 8'-0" CJ PER PLAN (E) FRAMING TO REMAIN (E) RAISED FLOOR (N) A.D.U. BEDROOM SEE ASSOCIATED NOTES ATTACHED
DRAWN SHEET SCALE JOB NO. DATE OF SHEETS CHECKED BYREVISIONS A-6