Skip to main content

FSM Ultraflex Flexible Flue Liner

Page 1

Flexible Flue Liner Products

Wood & Multi Fuel Appliances


About FSM Group FSM is one of the leading Chimney & Flue manufacturers in Uk, producing around half a million quality steel products every year. FSM Group is a family-run company with over 40 years direct experience of selling chimney products to the UK chimney trade and retail sector. All our products have been selected from quality manufacturers and are trusted by trade installers across the UK. We believe our products should give you both value for money as well as peace of mind. .

Good quality. Good price. What more could I want. Fitted next day, easily.

We have manufacturing

2


Why Choose ULTRAFLEX? Our ULTRAFLEX liners are all of stainless steel twin-lined grade 1 quality and produced to the highest of standards. The liners are designed to withstand high temperatures and has a good resistance to corrosion. We produce different liners; 316L/316L and 904/904, each designed to perform under various circumstances depending on the types of fuel used. We also stock a wide range of fittings to use in the installation of our liners. All of our flexible liner products are of the highest quality and a variety are available to suit the individual needs of the customer.

OUR COMMITMENT WE NEVER COMPROMISE ON QUALITY

THINK QUALITY THINK ULTRAFLEX Originally designed as just a liner, the huge success meant we were asked to develop a wider range. So, we listened to our customers and expanded our product range. The Ultraflex brand now includes: • Flexible Chimney Flue Liner • Flue / Chimney Adaptors • Register Plates • Supports • Terminals • Cowls

facilities across the UK , supplying premium products around the country.

3


Ultraflex Specification Designation EN 1856

Standard No. Temperature Rating

T600

Corrosion Resistence

L500

Liner Material

P1

Pressure Rating

VM

Condensation Resistence

Material Thickness

W

Soot Fire Resistence

12 G

Specification Specification Materials

Product 316/316L

904/904

Stainless Steel 316L Inner and Outer

Stainless Steel 904 Inner and Outer

Construction

The inner wall is of smooth bore construction giving extremely low resistence to the flue gas flow. The outer wall has a convoluted profile with a crimp and locked seam. The two walls are seamed together throughout the length to ensure its stability and integrity.

Performance

Normal Operating temperature of upto 450°C for solid fuel and 250°C for gas and oil.

Fuels

Gas, Oil, Coke, Cured Dry Logs, Cured Dry Peat and Smokeless Fuels.

Gas, Oil, Coke, Cured Dry Logs and Cure Dry Peat.

Recommended for slumbering or for boiler models.

Operation

The liner will withstand thermal shock at 1000°C for a short duration in emergencies. However, int the event of a chimney fire, the product will need to be checked by a competent person before re-use. Such high temperatures can have a detrimental effect on the product life.

Installation

The product must be installed and commissioned by a competent professional installer.

Maintenance

The chimney must be swept at least once a year by a professional sweep. Do not use chimney cleaners and only non-metallic brushes.

Life Expectancy Guarantee

Lifetime Warranty* The lifetime you own the property In order to register for the guarantee you will need to complete a product registration form, subject to condition. The life expectancy is based on normal operation with correctly set and operated appliances using the appropriate fuels of recognised quality and low sulphur content. Please Note: if “slumbering”, the 904 liner should be used.

Designation

EN1856-T600-P1-W-VM-L500-12-G

EN1856-T600-P1-W-VM-L700-12-G

Curvature The liner’s flexibility allows it to be handled and installed with a minimum curvature radii whilst avoiding any damage to the inside of the liner. Do not overbend or kink the liner. Internal Diameter

125 150 175 200

Minimum Curvature Radius

315 360 420 470

When installing the liner, please note that the arrows marked on the liner need to face up the chimney, indicating the direction of the flue gases. Incorrect installation can result in faster build-up of deposits and a greater chance of a chimney fire.

4


Ultraflex Quality Our liners and products have all been quality tested. liner has been tested by BSRIA and has a designation number of EN1856- T600-P1-W-VM-L500-12-G.

Dimensions Diameter

4”

5”

6”

7”

8”

10”

Internal Diameter (mm)

100

125

150

175

200

250

External Diameter

107

131

156

181

206

258

Coil length

40

40

40

30

30

30

5


Installation Guide Before you install your liner:

Introduction

Ensure your brick chimney stack has been thoroughly swept, cleaned and is clear of any debris. Carry out any rectification work on the exposed section of the chimney stack prior to installing your flexible flue liner e.g. re-pointing.

Unpacking the liner: When unpacking the liner, remove packaging and uncoil from the outside. Uncoiling from the inside will potentially exceed the maximum curvature radii of the liner, cause damage to its structure and void the warranty.

The nominal size of the liner: A minimum of 25mm between the flue liner and the wall of the chimney stack must be maintained along the full length of the liner. For example, in a 9”x 9” chimney, a maximum of a 7” liner should be used.

Test-pull your installation: To ensure your flexible liner will pass cleanly through the chimney, we would advise a “test-pull”. This means using a test piece (we suggest a minimum of 1mtr) of the correct diameter flexible liner that you wish to install. Connect a nose cone to both ends of the test piece with drawstrings attached, long enough for the length of the chimney, then pass the liner through your chimney in the direction you intend to install it. If your test-pull is successful, whereby the diameter liner fits your chimney stack and you do not encounter any blockages, you should continue your installation without any problems.

Alternative top fixings diagram Top Sleeve Top Plate

Top Clamp

Site preparation and cutting the liner: Please wear heavy-duty gloves when handling the flexible liner as it has very sharp edges and could injure at ease if handled incorrectly. Using a hacksaw is the most common way to cut flexible liner. Ensure you secure the liner on a solid and secure flat surface, using tin snips to tidy up any rough ends. Once your liner has been cut, tape the ends using duct tape which will help ensure you do not cut yourself whilst installing the liner. Remove the tape once it has been installed. (See Figure 3). Please ensure you have the appropriate working platform in place on the roof to enable a safe installation of your liner. Health and safety must be at the forefront of your mind when installing and handling your flexible liner.

Fitting your flexible liner: You can install your flexible liner either from the top or bottom of the brick chimney stack. Whichever way you choose to install the liner, please ensure that you have sufficient clearance around the outside of the liner to ensure the least amount of friction, or possibility of catching any bricks within the chimney stack, does not occur. Unpack your flexible liner and, attaching a drawstring to the nose cone, (making sure it is long enough to reach the bottom of the stack), connect the nose cone to the end of the liner using gaffer tape. Ensure the arrows marked on the liner are facing an upward direction (representing the direction of flue gases). (See “Completed install” diagram). The inside of a flue liner is designed to be like weather-boarding on a building, with each board overlapping the next. The idea of the lap on the inside is so that any soot/tar/creosote that runs back down the liner will run over the joints. The diagram on the left shows how the liner is designed to do this. You will need two people to install your liner successfully, one at either end of the chimney stack. From the top of the roof, start to push the liner, nose cone first, down the stack. The person at the bottom of the stack should hold the string and take up the slack. Work in tandem to feed the liner down the chimney stack, ensuring you leave enough liner at the bottom to secure your adaptor and enough at the top to secure the top fixings. (See “Completed install” diagram).

6


Suspending Cowl

Chimney Pot

Insulation materials: FSM recommends you back fill your chimney with either Vermiculite or alternatively, Rockwall insulation. Rockwall comes in fixed 1mtr lengths, 25mm thick, whilst the Vermiculite is a loose-fill material which is much easier to install with your liner. Both materials increase the efficiency of your chimney and will help avoid any corrosion of your liner. Another alternative is air-gap venting. This is a simple way to maintain the air gap simply by inserting 2x 15mm copper pipes horizontally at the top of the chimney stack. You must not however, exceed a venting area of 52cm.

Annual maintenance:

Flexible Liner

Insulation (Optional)

Adaptor Register Plate

All chimneys should be swept and inspected by a competent person at least once every year (often more depending on the fuel you are burning). Your chimney could suffer from soot build-up within the flexible liner, especially if wet, unseasoned wood, coal or low grade fuels have been used. To ensure your liner is safe to use, a yearly sweep (using a polypropylene brush not a metal wire brush which can potentially damage the liner) and the annual inspection reduces the chance of soot build-up and therefore reduces the chance of a chimney fire. Any chimney fire could affect the structural strength of your liner and should be inspected after any chimney fire occurs. The correct type and size of brush for the liner must be used when cleaning; a brush too big could potentially get stuck. FSM recommends a polypropylene brush not a metal wire brush as this could actually damage the liner. You must not use chemical cleaners.. Your flexible liner is constructed from either 316 or 904 stainless steel and has been tested to EN-1856 (CE Approved) and will withstand constant operating temperatures of 540° C, and 760°C on short fire operation.

Legal requirements: Access Door (For Cleaning)

On completion of the installation it should be commissioned with appropriate requirements, including a smoke test. This will check for any leaks or substantial spillages from the liner which will need rectifying before the appliance is used. It is a legal requirement to fit a chimney notice plate on any installation or modification to your existing installation. Your notice plate should be fitted either in your utility meter cupboard or close to the fire or woodstove. You should never cover this plate.

Completed Installation Diagram

Also, a carbon monoxide detector and an air vent should be installed in the same room as the appliance. Please refer to the Document J Building Regulations for more details.

Please note: The liner should not be fitted directly to the appliance. A short length of either vitreous or 316 stainless steel (preferably with a clean-out door for sweeping) should be fitted from the appliance to the liner adaptor.

7


FLUE LINER ADAPTORS

We Are Commited To Our Customers FSM Group will only provide the higest quality products to our customers and constantly check they are of the highest standard.

8


Adaptors Stove Adaptor B

B

Adaptor to attach flexible liner to vitreous/316 stove pipe.

50mm A

A

B

B

5”

6”

7”

8”

10”

ø

100

125

150

175

200

250

A

96

121

148

172

195

245

B

112

140

170

200

215

265

50 mm

100 mm

4” D

B

Screw Adaptor 60 mm

B

5”

A

160mm

200 mm 90mm 250 mm

160mm

80mm

Screw adaptor to attach flexible liner to vitreous /316 stove pipe. 7”

8”

ø

125

150

175

200

A

121

148

173

198

B

136

160

186

214

C

A

A

A

Wingnut Adaptor A

AB

B

Adaptor to attach flexible liner to vitreous/316 stove pipe.

450mm

300 mm

A

22 0m m

980mm

980mm

200 mm

250 mm

A

A

B

195

245

112

140

170

200

215

265

600mm

ø C

A

A

5”

6”

7”

8”

125

150

175

200

121

148

170

190

5” - 6”

100

125

95

123 200 mm

ø A

340 mm

240mm

4” - 5”

6” - 7”

7” - 8”

150

175

148

173

B

140

170

200

215

D

115

120

120

120

B

Screw Adaptor / Increasing

Increasing screw adaptor to attach flexible liner to smaller diameter vitreous/316 stove pipe.

ø A A

A

A

A B

300mm

B

160mm

80mm

C

22 0m m

B

160mm

60 mm

mm 300

A

250 mm

172

300mm

A 300 mm

B

200 mm

148

Long-tail adaptor to attach flexible liner to vitreous /316 stove pipe. Used when adjustment is required.

340mm

200 mm

50 mm

100 mm

A

30 0m m

121

Increasing adaptor to attach flexible liner to smaller diameter vitreous/316 stove pipe.

mm 300

B

96

A

D

A

10” 250

Stove Adaptor / Increasing

A

50mm

8” 200

980mm

mm 300

B

A

7” 175

B

A

B

6” 150

4” - 5”

5” - 6”

6” - 7”

7” - 8”

100

125

150

175

98

120

-

-

135

163

-

-

90mm

190mm

135mm

300mm

5” 125

Stove Adaptor / Adjustable

B

A

B

A

4” 100

60 mm

30 0m m

A

120mm

A

B

300mm

A

200 mm

A

155mm

135mm

300mm

340mm

50mm

50mm

m

ø

D

340 mm

100 mm

310mm

200 mm

100mm

50 mm

B

B

A

6”

9


9

80m

Adaptors

A

A

310mm

A

121 140

120mm

90mm

A

B

148

176

173

170

200

215

Top hat adaptor to attach flexible liner to vitreous stove pipe.Can be adjusted in the sleeve up or down by 130mm B 310mm

ø 155mm

135mm

300mm

mm 300 AA 300 mm

mm 300

A

5”

6”

7”

8”

125

150

175

200

A

120

146

170

196

B

142

170

192

215

A

Register Plate / Increasing Adaptor A 300 mm

160mm

B

Register plate adaptor with plate 300mm X 300mm to attach flexible liner to vitreous/316 stove pipe.

300 mm

190mm

90mm

8” 200

240mm

190mm

135mm

300mm

190mm

7” 175

Top Hat Adaptor

300 mm

240mm

190mm

6” 150

120mm

B

B

4” - 5”

5” - 6”

6” - 7”

7” - 8”

100

125

150

175

A

98

121

148

173

B

140

170

200

215

ø

B

240mm

135mm

300mm

A

5” 125

A

B

B

ø

A

A

300 mm

155mm

160mm

135mm

300mm

A

Register310mm plate adaptor with plate 300mm X 300mm to attach flexible liner to vitreous/316 stove pipe.

B

160mm

120mm

300 mm

80mm

190mm

155mm

135mm

B

300 mm

mm

A

mm 300

Sump Adaptor / Clay Liner Adaptor A 300 mm

310mm

used to connect from single skin stove pipe to clay, pumice or concrete flue liners.

120mm

155mm D

50mm

A A

7”

8”

150

175

200

A

121

148

170

190

Connect adaptor allows two length of Flexible Flue liner to be joined together. 60 mm

300 mm

4”

B

A

250 mm

6”

125

Connect Adaptor B

240mm

C

10

5” ø

50 mm

100 mm

135mm

B

200 mm

190mm

Register Plate / Adaptor

B

300mm

mm 300

A

5”

6”

7”

8”

10”

ø

100

125

150

175

200

250

A

154

154

154

154

154

154

B

112

136

167

186

211

265

C

96

123

150

170

195

245


Gather Hoods & Register Plates

BESPOKE SERVICE AVAILABLE We offer a quick 5-10 working day service for making gathers to your dimensions and specifications.

We offer a quick 2 - 3 working day service for making register plates to your dimensions and specifications.

11


A

100 mm

C

D

50 mm

250 mm

200 mm

B

B

50mm

A

A A

A

A

m m

mm 300

Gather Hood 300 x 220mm 60 mm

Fitted at the base of the chimney where an open fire is used. Please call for prices if other sizes are required.

340 A mm

200 mm

200 mm

250 mm

B

340mm

200 mm

B

5”

C

22 0m m

A

6”

7”

8”

ø

125

150

175

200

A

121

148

172

195

300mm

A

A

30 0m m

mm 300

340mm

5”

22 0m m

340 mm

Fitted at the base of the chimney where an open fire is used. Please call for prices if other sizes are required. 200 mm

200 mm

Gather Hood 300 x 300mm

6”

7”

8”

ø

125

150

175

200

A

121

148

176

173

Register Plate 36” x 12” 300mm

300mm

A

Register Plate 36” x 12” complete with adjustable plate for ease of installation. Plate can be lowered for inspection of chimney liner. Comes with 2 x angle brackets for fixing. * Also available without hole Please Note: Adjustable plate is only front and back movement.

7”

8”

150

175

200

A

121

148

170

190

B

Register Plate / 36” x 18” 50mm

100mm

50mm

Register Plate 36” x 18” complete with adjustable plate for ease of installation. Plate can be lowered for inspection of chimney liner. Comes with 2 x angle brackets for fixing. * Also available without hole B

A

100mm

A

100mm

450mm

Please Note: Adjustable plate is only front and back movement. 50mm

450mm

A

600mm

A A

600mm

600mm

A

980mm

6”

125

ø

980mm 980mm

5” ø

5”

6”

7”

8”

125

150

175

200

121

148

170

190

Register Plate / 36” x 24” Register Plate 36” x 24” complete with adjustable plate for ease of installation. Plate can be lowered for inspection of chimney liner. Comes with 2 x angle brackets for fixing. * Also available without hole Please Note: Adjustable plate is only front and back movement.

5” 980mm 980mm

12

B

A

450mm

A

A

980mm

980mm

A

300mm

A

980mm

300mm

A

980mm

6”

7”

8”

ø

125

150

175

200

A

121

148

170

190


SUPPORT COMPONENTS

British Design British Made FSM customers can be rest assured that we never cut corners in our manufacturing process and never will.

13


Support Components

200mm

120mm A A 300mm

Base Support Bracket Used to secure flexible liner to the base of the chimney stack. A

200mm

Productss

120mm 135mm A

5”

6”

7”

8”

ø

125

150

175

200

A

130 330mm

155

180

210

A

300mm A

250mm 135mm

300mm A

Top Plate A

The top plate is fitted at the top of the chimney stack and is constructed to allow the liner to pass through it. Used in conjunction with the top clamp. 80mm

330mm

380 mm

4” 5” 300mm A

200mm

120mm 380mm

380 mm

10”

125

150

175

200

250

115 140 300mm

165

190

213

265

160mm 300mm 80mm

The top clamp is used to secure the liner to the top A of the chimney stack, above the top plate at point of A 300mm termination.

A 330mm 120mm 160mm

8”

Top Clamp

A

35mm

7”

250mm

300mm

A

ø A

6”

A 100

300mm

380mm A 300mm 330mm

200mm

4”

5”

6”

ø

100

125

150

A

107

130

155

300mm

7”

8”

10”

175

200

250

180160mm 210

258

175mm A

Top Sleeve AA

A

300mm

250mm

Used to strengthen the flue liner at the top stack. A Slides inside the liner to give added strength.

330mm 135mm

380 mm

4”

80mm

160mm

A A A 300mm

250mm

A A 300mm

14

150

175

200

250

96300mm 121

148

171

195

245

A

Nose Cone

A A

380mm

175mm

10”

Liner nose cone to help install the chimney liner. 80mm These are made from plastic or aluminium. (Available in 4” - 10” Diameters)

380 mm

330mm

7”175mm 8”

ø

200mm

120mm

6”

A

300mm

160mm

5”

330mm 100 125

300mm


CHIMNEY COWLS

Manufactured In The UK By FSM All our Ultraflex cowls are engineered, designed and manufactured by FSM for the best quality product.

15


Chimney Cowl

160mm

200mm

120mm A

Rain Cap

300mm A

330mm

Fits to the top of the flexible liner preventing any rain ingress into the chimney.

175mm A

mm

A 330mm

6”

7”

8”

10”

ø

100

125

150

175

200

250

A

112

135

165

190

210

260

Rain Cap With Mesh 300mm

Fits to the top of the flexible flue liner preventng any rain ingress into the chimney. 200mm

200mm 120mm 200mm

A

120mm 380 mm

5”

300mm

300mm 300mm

250mm

4”

80mm

5”

6”

7”

8”

ø

125

150

175

200

A

135

165

A A 300mm

Pot Hanger

A

Fits to the A top of the flexible flue liner.

A 135mm

A

5mm

This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install).

160mm

330mm 300mm

330mm

ø A

A 330mm A 300mm 300mm

mm

175mm 250mm A 80mm A

380 mm

380 mm

250mm

A 380mm 300mm 300mm

6”

7”

8”

150

175

200

300mm

148

171

195

121

Used as a one piece system to secure the liner at the top of the stack.

This product is mainly used where the clay pot is being used (as there is 80mm no need to remove the pot to install). Also available in terracotta.

5”

6”

7”

8”

ø

125

150

175

200

A

300mm 121

148

-

-

A

Star Clamp Suspending Cowl 160mm

160mm 160mm

This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta.

A

A

300mm

300mm A

330mm

300mm 160mm

5”

125

330mm

Supending Cowl Screw Type

80mm

A 300mm

330mm

5”

6”

7”

8”

ø

125

150

175

200

A

121

148

171

195

175mm

175mm 175mm

A

16

A

A

A

A


Suspending Cowl

300mm

Used as a one piece system to secure the liner at 300mm the top of the stack.

300mm

This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta.

330mm

5”

6”

7”

8”

ø

125

150

175

200

A

121

148

171

195

330mm

330mm

160mm

160mm

330mm

160mm A A

Supending Cowl Mini A

300mm 225mm

Used as a one piece system to secure the liner at the top of the stack.

This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta.

225mm

5”

6”

7”

8”

ø

125

150

175

200

A

121

148

171

195

125mm

A

Suspending Cowl 300mm

300mm

Square Based Used as a one piece system to secure the liner at the top of the stack.

This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta. The Base Plate of the cowl is 335mm x 335mm.

330mm

160mm

330mm

160mm

A

5”

6”

7”

8”

ø

125

150

175

200

A

121

148

171

195

A

300mm

225mm 125mm

A

17


Information General Notes 1. Ensure your liner is fitted and swept by a professional installer and/ or sweep. 2. It is essential the liner is installed with the arrows facing an upward direction. 3. Flue Supplies recommends that the chimney is swept and inspected at least twice a year, ideally at the middle and end of the heating season. Failure to maintain a clean chimney can potentially cause a chimney fire and the emission of toxic gases. Keep all sweeping certificates and invoices for any possible claims. 4. In the event of a chimney fire, all products need to be inspected by a competant person to ensure the system is safe to use. 5. Do not burn household refuse.

6. Do not block or cover the appliance or chimney outlets. 7. Slumbering the fire for prolonged periods of time will decrease the life expectancy of the liner. It is recommended to run the appliance at a controlled high fire temperature within each firing for at least 30mins if slumbering overnight. Using a thermometer will allow you to monitor flue gas temperatures. 8. Do not use chemical cleaners or metal brushes. 9. It is advised to use only the fuel recommended by the appliance manufacturer and a liner suitable for burning that fuel. Using the wrong fuel for the liner will decrease the life of the product. 10. It is a legal requirement to fit a chimney notice plate on any installation, either by the fire itself or in a utility cupboard. A carbon monoxide detector and air vent must also be fitted in the same room as the appliance.

Component Installation Flue Liner Adaptor Push the bottom end of ultraflex liner into the cavity between the inner and outer skin of the stainless steel adaptor, then drill through the outer skin, and secure with three self tapping screws,(not supplied)now fill any gaps between the liner and outer skin of adaptor with fire cement, (note: do not push fire cement inside the cavity before liner is inserted as will block the drainage holes) lastly push the bottom of the adaptor inside the flue pipe and seal with fire cement.

Register Plate Adaptor Push the bottom end of ultraflex liner into the cavity between the inner and outer skin of the stainless steel adaptor, then drill through the outer skin, and secure with three self tapping screws,(not supplied)now fill any gaps between the liner and outer skin of adaptor with fire cement,(note do not push fire cement inside the cavity before liner is inserted as will block the drainage holes, the attached square plate can now be secured in place, now attach your single skin pipe to the underside of the adaptor and seal with fire cement.

Sump Adaptor Drill some holes through the circular ring and abut to underside of clay liner, (normally cast in concrete slab) mark positions of fixing holes to concrete and drill. Now apply sealant to circular ring and secure adaptor to underside of clay liner. (Fixings not supplied) now attach your single skin pipe to the underside of the adaptor and seal with fire cement.

Gather Unit Push the bottom end of ultraflex liner into the cavity between the inner and outer skin of the stainless steel adaptor, then drill through the outer skin, and secure with three self tapping screws, (not supplied) now fill any gaps between the liner and outer skin of adaptor with fire cement, (note do not push fire cement inside the cavity before liner is inserted as will block the drainage holes) lastly push the bottom of the adaptor inside the flue pipe and seal with fire cement. Now the liner will need to be pulled up the chimney whilst the gather unit is positioned, and secured in place.

18


Base Support Bracket Normally fixed at base of liner above register plate, and secured to wall. (fixings not supplied)

Register Plate The metal plate and supporting angle brackets will need cutting to size. Secure the brackets to the inside of the chimney (fixings not supplied) the single skin pipe from the appliance will need to pass through the adjustable centre plate.

Top plate Fitted with a top sleeve and clamp. With the flexible liner protruding from the top of the masonry chimney, feed the plate over the end of liner and place on top of brickwork cut the liner approximately 125 mm above the plate, insert the top sleeve. Now fit the clamp around the liner on top of the plate and tighten, (optional rain cap can be fitted) the plate will then need to be made watertight with sand and cement. Or finished off with a traditional chimney pot.

Top Insert i.e. protection sleeve, protects the flue liner termination, and should be fitted when supporting the liner from a top clamp, Basic cowl with or without mesh, first fit a top insert, then place rain cap base over outside of liner ,drill through the base and secure to liner with self tapping screws (not supplied)

Pot Hanger normally fitted to a chimney pot. With the liner protruding from the pot push the sleeve inside the liner, the three straps attached to the sleeve are then secured to the flexible liner with a fastening strap, now continue pushing the liner inside the pot until the base of the hanger rests on top, now bend the three outer straps down the outside of pot and secure with the second fastening strap, an optional anti downdraught cowl can be fitted, now or at a later date

Suspending Cowl With the liner protruding from the chimney pot push the sleeve inside the liner, the three straps attached to the sleeve are then secured to the flexible liner with a fastening strap, now continue pushing the liner inside the pot until the base of the suspending cowl rests on top, now bend the three outer straps down the outside of pot and secure with the second fastening strap,

Nose Cone tie a knot to your draw string (not supplied) pass string through hole in nose cone, tie a suitable weight to the end of draw string, now secure the cone to the bottom end of liner with duck tape etc, drop the draw string down the chimney and feed liner down .the nose cone will protect the end of liner and assist the installation.

Chimney Notice Plate The installer shall enter the information required with a permanent marker pen, the plate should be left close to the appliance or by consumer unit.

19


ISO 9001 FS 576960

FSM Group, Unit 6-7, Link 20, Bellingham Way, Aylesford, Kent, ME20 7HD Tel: 0344 800 6586 Email: info@fsmgroup.co.uk Copyright fsm group 2021 ©


Turn static files into dynamic content formats.

Create a flipbook
FSM Ultraflex Flexible Flue Liner by FSM Group - Issuu