About FSM Group FSM is one of the leading Chimney & Flue manufacturers in Uk, producing around half a million quality steel products every year. FSM Group is a family-run company with over 40 years direct experience of selling chimney products to the UK chimney trade and retail sector. All our products have been selected from quality manufacturers and are trusted by trade installers across the UK. We believe our products should give you both value for money as well as peace of mind. .
Good quality. Good price. What more could I want. Fitted next day, easily.
We have manufacturing
2
Why Choose ULTRAFLEX? Our ULTRAFLEX liners are all of stainless steel twin-lined grade 1 quality and produced to the highest of standards. The liners are designed to withstand high temperatures and has a good resistance to corrosion. We produce different liners; 316L/316L and 904/904, each designed to perform under various circumstances depending on the types of fuel used. We also stock a wide range of fittings to use in the installation of our liners. All of our flexible liner products are of the highest quality and a variety are available to suit the individual needs of the customer.
OUR COMMITMENT WE NEVER COMPROMISE ON QUALITY
THINK QUALITY THINK ULTRAFLEX Originally designed as just a liner, the huge success meant we were asked to develop a wider range. So, we listened to our customers and expanded our product range. The Ultraflex brand now includes: • Flexible Chimney Flue Liner • Flue / Chimney Adaptors • Register Plates • Supports • Terminals • Cowls
facilities across the UK , supplying premium products around the country.
3
Ultraflex Specification Designation EN 1856
Standard No. Temperature Rating
T600
Corrosion Resistence
L500
Liner Material
P1
Pressure Rating
VM
Condensation Resistence
Material Thickness
W
Soot Fire Resistence
12 G
Specification Specification Materials
Product 316/316L
904/904
Stainless Steel 316L Inner and Outer
Stainless Steel 904 Inner and Outer
Construction
The inner wall is of smooth bore construction giving extremely low resistence to the flue gas flow. The outer wall has a convoluted profile with a crimp and locked seam. The two walls are seamed together throughout the length to ensure its stability and integrity.
Performance
Normal Operating temperature of upto 450°C for solid fuel and 250°C for gas and oil.
Fuels
Gas, Oil, Coke, Cured Dry Logs, Cured Dry Peat and Smokeless Fuels.
Gas, Oil, Coke, Cured Dry Logs and Cure Dry Peat.
Recommended for slumbering or for boiler models.
Operation
The liner will withstand thermal shock at 1000°C for a short duration in emergencies. However, int the event of a chimney fire, the product will need to be checked by a competent person before re-use. Such high temperatures can have a detrimental effect on the product life.
Installation
The product must be installed and commissioned by a competent professional installer.
Maintenance
The chimney must be swept at least once a year by a professional sweep. Do not use chimney cleaners and only non-metallic brushes.
Life Expectancy Guarantee
Lifetime Warranty* The lifetime you own the property In order to register for the guarantee you will need to complete a product registration form, subject to condition. The life expectancy is based on normal operation with correctly set and operated appliances using the appropriate fuels of recognised quality and low sulphur content. Please Note: if “slumbering”, the 904 liner should be used.
Designation
EN1856-T600-P1-W-VM-L500-12-G
EN1856-T600-P1-W-VM-L700-12-G
Curvature The liner’s flexibility allows it to be handled and installed with a minimum curvature radii whilst avoiding any damage to the inside of the liner. Do not overbend or kink the liner. Internal Diameter
125 150 175 200
Minimum Curvature Radius
315 360 420 470
When installing the liner, please note that the arrows marked on the liner need to face up the chimney, indicating the direction of the flue gases. Incorrect installation can result in faster build-up of deposits and a greater chance of a chimney fire.
4
Ultraflex Quality Our liners and products have all been quality tested. liner has been tested by BSRIA and has a designation number of EN1856- T600-P1-W-VM-L500-12-G.
Dimensions Diameter
4”
5”
6”
7”
8”
10”
Internal Diameter (mm)
100
125
150
175
200
250
External Diameter
107
131
156
181
206
258
Coil length
40
40
40
30
30
30
5
Installation Guide Before you install your liner:
Introduction
Ensure your brick chimney stack has been thoroughly swept, cleaned and is clear of any debris. Carry out any rectification work on the exposed section of the chimney stack prior to installing your flexible flue liner e.g. re-pointing.
Unpacking the liner: When unpacking the liner, remove packaging and uncoil from the outside. Uncoiling from the inside will potentially exceed the maximum curvature radii of the liner, cause damage to its structure and void the warranty.
The nominal size of the liner: A minimum of 25mm between the flue liner and the wall of the chimney stack must be maintained along the full length of the liner. For example, in a 9”x 9” chimney, a maximum of a 7” liner should be used.
Test-pull your installation: To ensure your flexible liner will pass cleanly through the chimney, we would advise a “test-pull”. This means using a test piece (we suggest a minimum of 1mtr) of the correct diameter flexible liner that you wish to install. Connect a nose cone to both ends of the test piece with drawstrings attached, long enough for the length of the chimney, then pass the liner through your chimney in the direction you intend to install it. If your test-pull is successful, whereby the diameter liner fits your chimney stack and you do not encounter any blockages, you should continue your installation without any problems.
Alternative top fixings diagram Top Sleeve Top Plate
Top Clamp
Site preparation and cutting the liner: Please wear heavy-duty gloves when handling the flexible liner as it has very sharp edges and could injure at ease if handled incorrectly. Using a hacksaw is the most common way to cut flexible liner. Ensure you secure the liner on a solid and secure flat surface, using tin snips to tidy up any rough ends. Once your liner has been cut, tape the ends using duct tape which will help ensure you do not cut yourself whilst installing the liner. Remove the tape once it has been installed. (See Figure 3). Please ensure you have the appropriate working platform in place on the roof to enable a safe installation of your liner. Health and safety must be at the forefront of your mind when installing and handling your flexible liner.
Fitting your flexible liner: You can install your flexible liner either from the top or bottom of the brick chimney stack. Whichever way you choose to install the liner, please ensure that you have sufficient clearance around the outside of the liner to ensure the least amount of friction, or possibility of catching any bricks within the chimney stack, does not occur. Unpack your flexible liner and, attaching a drawstring to the nose cone, (making sure it is long enough to reach the bottom of the stack), connect the nose cone to the end of the liner using gaffer tape. Ensure the arrows marked on the liner are facing an upward direction (representing the direction of flue gases). (See “Completed install” diagram). The inside of a flue liner is designed to be like weather-boarding on a building, with each board overlapping the next. The idea of the lap on the inside is so that any soot/tar/creosote that runs back down the liner will run over the joints. The diagram on the left shows how the liner is designed to do this. You will need two people to install your liner successfully, one at either end of the chimney stack. From the top of the roof, start to push the liner, nose cone first, down the stack. The person at the bottom of the stack should hold the string and take up the slack. Work in tandem to feed the liner down the chimney stack, ensuring you leave enough liner at the bottom to secure your adaptor and enough at the top to secure the top fixings. (See “Completed install” diagram).
6
Suspending Cowl
Chimney Pot
Insulation materials: FSM recommends you back fill your chimney with either Vermiculite or alternatively, Rockwall insulation. Rockwall comes in fixed 1mtr lengths, 25mm thick, whilst the Vermiculite is a loose-fill material which is much easier to install with your liner. Both materials increase the efficiency of your chimney and will help avoid any corrosion of your liner. Another alternative is air-gap venting. This is a simple way to maintain the air gap simply by inserting 2x 15mm copper pipes horizontally at the top of the chimney stack. You must not however, exceed a venting area of 52cm.
Annual maintenance:
Flexible Liner
Insulation (Optional)
Adaptor Register Plate
All chimneys should be swept and inspected by a competent person at least once every year (often more depending on the fuel you are burning). Your chimney could suffer from soot build-up within the flexible liner, especially if wet, unseasoned wood, coal or low grade fuels have been used. To ensure your liner is safe to use, a yearly sweep (using a polypropylene brush not a metal wire brush which can potentially damage the liner) and the annual inspection reduces the chance of soot build-up and therefore reduces the chance of a chimney fire. Any chimney fire could affect the structural strength of your liner and should be inspected after any chimney fire occurs. The correct type and size of brush for the liner must be used when cleaning; a brush too big could potentially get stuck. FSM recommends a polypropylene brush not a metal wire brush as this could actually damage the liner. You must not use chemical cleaners.. Your flexible liner is constructed from either 316 or 904 stainless steel and has been tested to EN-1856 (CE Approved) and will withstand constant operating temperatures of 540° C, and 760°C on short fire operation.
Legal requirements: Access Door (For Cleaning)
On completion of the installation it should be commissioned with appropriate requirements, including a smoke test. This will check for any leaks or substantial spillages from the liner which will need rectifying before the appliance is used. It is a legal requirement to fit a chimney notice plate on any installation or modification to your existing installation. Your notice plate should be fitted either in your utility meter cupboard or close to the fire or woodstove. You should never cover this plate.
Completed Installation Diagram
Also, a carbon monoxide detector and an air vent should be installed in the same room as the appliance. Please refer to the Document J Building Regulations for more details.
Please note: The liner should not be fitted directly to the appliance. A short length of either vitreous or 316 stainless steel (preferably with a clean-out door for sweeping) should be fitted from the appliance to the liner adaptor.
7
FLUE LINER ADAPTORS
We Are Commited To Our Customers FSM Group will only provide the higest quality products to our customers and constantly check they are of the highest standard.
8
Adaptors Stove Adaptor B
B
Adaptor to attach flexible liner to vitreous/316 stove pipe.
50mm A
A
B
B
5”
6”
7”
8”
10”
ø
100
125
150
175
200
250
A
96
121
148
172
195
245
B
112
140
170
200
215
265
50 mm
100 mm
4” D
B
Screw Adaptor 60 mm
B
5”
A
160mm
200 mm 90mm 250 mm
160mm
80mm
Screw adaptor to attach flexible liner to vitreous /316 stove pipe. 7”
8”
ø
125
150
175
200
A
121
148
173
198
B
136
160
186
214
C
A
A
A
Wingnut Adaptor A
AB
B
Adaptor to attach flexible liner to vitreous/316 stove pipe.
450mm
300 mm
A
22 0m m
980mm
980mm
200 mm
250 mm
A
A
B
195
245
112
140
170
200
215
265
600mm
ø C
A
A
5”
6”
7”
8”
125
150
175
200
121
148
170
190
5” - 6”
100
125
95
123 200 mm
ø A
340 mm
240mm
4” - 5”
6” - 7”
7” - 8”
150
175
148
173
B
140
170
200
215
D
115
120
120
120
B
Screw Adaptor / Increasing
Increasing screw adaptor to attach flexible liner to smaller diameter vitreous/316 stove pipe.
ø A A
A
A
A B
300mm
B
160mm
80mm
C
22 0m m
B
160mm
60 mm
mm 300
A
250 mm
172
300mm
A 300 mm
B
200 mm
148
Long-tail adaptor to attach flexible liner to vitreous /316 stove pipe. Used when adjustment is required.
340mm
200 mm
50 mm
100 mm
A
30 0m m
121
Increasing adaptor to attach flexible liner to smaller diameter vitreous/316 stove pipe.
mm 300
B
96
A
D
A
10” 250
Stove Adaptor / Increasing
A
50mm
8” 200
980mm
mm 300
B
A
7” 175
B
A
B
6” 150
4” - 5”
5” - 6”
6” - 7”
7” - 8”
100
125
150
175
98
120
-
-
135
163
-
-
90mm
190mm
135mm
300mm
5” 125
Stove Adaptor / Adjustable
B
A
B
A
4” 100
60 mm
30 0m m
A
120mm
A
B
300mm
A
200 mm
A
155mm
135mm
300mm
340mm
50mm
50mm
m
ø
D
340 mm
100 mm
310mm
200 mm
100mm
50 mm
B
B
A
6”
9
9
80m
Adaptors
A
A
310mm
A
121 140
120mm
90mm
A
B
148
176
173
170
200
215
Top hat adaptor to attach flexible liner to vitreous stove pipe.Can be adjusted in the sleeve up or down by 130mm B 310mm
ø 155mm
135mm
300mm
mm 300 AA 300 mm
mm 300
A
5”
6”
7”
8”
125
150
175
200
A
120
146
170
196
B
142
170
192
215
A
Register Plate / Increasing Adaptor A 300 mm
160mm
B
Register plate adaptor with plate 300mm X 300mm to attach flexible liner to vitreous/316 stove pipe.
300 mm
190mm
90mm
8” 200
240mm
190mm
135mm
300mm
190mm
7” 175
Top Hat Adaptor
300 mm
240mm
190mm
6” 150
120mm
B
B
4” - 5”
5” - 6”
6” - 7”
7” - 8”
100
125
150
175
A
98
121
148
173
B
140
170
200
215
ø
B
240mm
135mm
300mm
A
5” 125
A
B
B
ø
A
A
300 mm
155mm
160mm
135mm
300mm
A
Register310mm plate adaptor with plate 300mm X 300mm to attach flexible liner to vitreous/316 stove pipe.
B
160mm
120mm
300 mm
80mm
190mm
155mm
135mm
B
300 mm
mm
A
mm 300
Sump Adaptor / Clay Liner Adaptor A 300 mm
310mm
used to connect from single skin stove pipe to clay, pumice or concrete flue liners.
120mm
155mm D
50mm
A A
7”
8”
150
175
200
A
121
148
170
190
Connect adaptor allows two length of Flexible Flue liner to be joined together. 60 mm
300 mm
4”
B
A
250 mm
6”
125
Connect Adaptor B
240mm
C
10
5” ø
50 mm
100 mm
135mm
B
200 mm
190mm
Register Plate / Adaptor
B
300mm
mm 300
A
5”
6”
7”
8”
10”
ø
100
125
150
175
200
250
A
154
154
154
154
154
154
B
112
136
167
186
211
265
C
96
123
150
170
195
245
Gather Hoods & Register Plates
BESPOKE SERVICE AVAILABLE We offer a quick 5-10 working day service for making gathers to your dimensions and specifications.
We offer a quick 2 - 3 working day service for making register plates to your dimensions and specifications.
11
A
100 mm
C
D
50 mm
250 mm
200 mm
B
B
50mm
A
A A
A
A
m m
mm 300
Gather Hood 300 x 220mm 60 mm
Fitted at the base of the chimney where an open fire is used. Please call for prices if other sizes are required.
340 A mm
200 mm
200 mm
250 mm
B
340mm
200 mm
B
5”
C
22 0m m
A
6”
7”
8”
ø
125
150
175
200
A
121
148
172
195
300mm
A
A
30 0m m
mm 300
340mm
5”
22 0m m
340 mm
Fitted at the base of the chimney where an open fire is used. Please call for prices if other sizes are required. 200 mm
200 mm
Gather Hood 300 x 300mm
6”
7”
8”
ø
125
150
175
200
A
121
148
176
173
Register Plate 36” x 12” 300mm
300mm
A
Register Plate 36” x 12” complete with adjustable plate for ease of installation. Plate can be lowered for inspection of chimney liner. Comes with 2 x angle brackets for fixing. * Also available without hole Please Note: Adjustable plate is only front and back movement.
7”
8”
150
175
200
A
121
148
170
190
B
Register Plate / 36” x 18” 50mm
100mm
50mm
Register Plate 36” x 18” complete with adjustable plate for ease of installation. Plate can be lowered for inspection of chimney liner. Comes with 2 x angle brackets for fixing. * Also available without hole B
A
100mm
A
100mm
450mm
Please Note: Adjustable plate is only front and back movement. 50mm
450mm
A
600mm
A A
600mm
600mm
A
980mm
6”
125
ø
980mm 980mm
5” ø
5”
6”
7”
8”
125
150
175
200
121
148
170
190
Register Plate / 36” x 24” Register Plate 36” x 24” complete with adjustable plate for ease of installation. Plate can be lowered for inspection of chimney liner. Comes with 2 x angle brackets for fixing. * Also available without hole Please Note: Adjustable plate is only front and back movement.
5” 980mm 980mm
12
B
A
450mm
A
A
980mm
980mm
A
300mm
A
980mm
300mm
A
980mm
6”
7”
8”
ø
125
150
175
200
A
121
148
170
190
SUPPORT COMPONENTS
British Design British Made FSM customers can be rest assured that we never cut corners in our manufacturing process and never will.
13
Support Components
200mm
120mm A A 300mm
Base Support Bracket Used to secure flexible liner to the base of the chimney stack. A
200mm
Productss
120mm 135mm A
5”
6”
7”
8”
ø
125
150
175
200
A
130 330mm
155
180
210
A
300mm A
250mm 135mm
300mm A
Top Plate A
The top plate is fitted at the top of the chimney stack and is constructed to allow the liner to pass through it. Used in conjunction with the top clamp. 80mm
330mm
380 mm
4” 5” 300mm A
200mm
120mm 380mm
380 mm
10”
125
150
175
200
250
115 140 300mm
165
190
213
265
160mm 300mm 80mm
The top clamp is used to secure the liner to the top A of the chimney stack, above the top plate at point of A 300mm termination.
A 330mm 120mm 160mm
8”
Top Clamp
A
35mm
7”
250mm
300mm
A
ø A
6”
A 100
300mm
380mm A 300mm 330mm
200mm
4”
5”
6”
ø
100
125
150
A
107
130
155
300mm
7”
8”
10”
175
200
250
180160mm 210
258
175mm A
Top Sleeve AA
A
300mm
250mm
Used to strengthen the flue liner at the top stack. A Slides inside the liner to give added strength.
330mm 135mm
380 mm
4”
80mm
160mm
A A A 300mm
250mm
A A 300mm
14
150
175
200
250
96300mm 121
148
171
195
245
A
Nose Cone
A A
380mm
175mm
10”
Liner nose cone to help install the chimney liner. 80mm These are made from plastic or aluminium. (Available in 4” - 10” Diameters)
380 mm
330mm
7”175mm 8”
ø
200mm
120mm
6”
A
300mm
160mm
5”
330mm 100 125
300mm
CHIMNEY COWLS
Manufactured In The UK By FSM All our Ultraflex cowls are engineered, designed and manufactured by FSM for the best quality product.
15
Chimney Cowl
160mm
200mm
120mm A
Rain Cap
300mm A
330mm
Fits to the top of the flexible liner preventing any rain ingress into the chimney.
175mm A
mm
A 330mm
6”
7”
8”
10”
ø
100
125
150
175
200
250
A
112
135
165
190
210
260
Rain Cap With Mesh 300mm
Fits to the top of the flexible flue liner preventng any rain ingress into the chimney. 200mm
200mm 120mm 200mm
A
120mm 380 mm
5”
300mm
300mm 300mm
250mm
4”
80mm
5”
6”
7”
8”
ø
125
150
175
200
A
135
165
A A 300mm
Pot Hanger
A
Fits to the A top of the flexible flue liner.
A 135mm
A
5mm
This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install).
160mm
330mm 300mm
330mm
ø A
A 330mm A 300mm 300mm
mm
175mm 250mm A 80mm A
380 mm
380 mm
250mm
A 380mm 300mm 300mm
6”
7”
8”
150
175
200
300mm
148
171
195
121
Used as a one piece system to secure the liner at the top of the stack.
This product is mainly used where the clay pot is being used (as there is 80mm no need to remove the pot to install). Also available in terracotta.
5”
6”
7”
8”
ø
125
150
175
200
A
300mm 121
148
-
-
A
Star Clamp Suspending Cowl 160mm
160mm 160mm
This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta.
A
A
300mm
300mm A
330mm
300mm 160mm
5”
125
330mm
Supending Cowl Screw Type
80mm
A 300mm
330mm
5”
6”
7”
8”
ø
125
150
175
200
A
121
148
171
195
175mm
175mm 175mm
A
16
A
A
A
A
Suspending Cowl
300mm
Used as a one piece system to secure the liner at 300mm the top of the stack.
300mm
This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta.
330mm
5”
6”
7”
8”
ø
125
150
175
200
A
121
148
171
195
330mm
330mm
160mm
160mm
330mm
160mm A A
Supending Cowl Mini A
300mm 225mm
Used as a one piece system to secure the liner at the top of the stack.
This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta.
225mm
5”
6”
7”
8”
ø
125
150
175
200
A
121
148
171
195
125mm
A
Suspending Cowl 300mm
300mm
Square Based Used as a one piece system to secure the liner at the top of the stack.
This product is mainly used where the clay pot is being used (as there is no need to remove the pot to install). Also available in terracotta. The Base Plate of the cowl is 335mm x 335mm.
330mm
160mm
330mm
160mm
A
5”
6”
7”
8”
ø
125
150
175
200
A
121
148
171
195
A
300mm
225mm 125mm
A
17
Information General Notes 1. Ensure your liner is fitted and swept by a professional installer and/ or sweep. 2. It is essential the liner is installed with the arrows facing an upward direction. 3. Flue Supplies recommends that the chimney is swept and inspected at least twice a year, ideally at the middle and end of the heating season. Failure to maintain a clean chimney can potentially cause a chimney fire and the emission of toxic gases. Keep all sweeping certificates and invoices for any possible claims. 4. In the event of a chimney fire, all products need to be inspected by a competant person to ensure the system is safe to use. 5. Do not burn household refuse.
6. Do not block or cover the appliance or chimney outlets. 7. Slumbering the fire for prolonged periods of time will decrease the life expectancy of the liner. It is recommended to run the appliance at a controlled high fire temperature within each firing for at least 30mins if slumbering overnight. Using a thermometer will allow you to monitor flue gas temperatures. 8. Do not use chemical cleaners or metal brushes. 9. It is advised to use only the fuel recommended by the appliance manufacturer and a liner suitable for burning that fuel. Using the wrong fuel for the liner will decrease the life of the product. 10. It is a legal requirement to fit a chimney notice plate on any installation, either by the fire itself or in a utility cupboard. A carbon monoxide detector and air vent must also be fitted in the same room as the appliance.
Component Installation Flue Liner Adaptor Push the bottom end of ultraflex liner into the cavity between the inner and outer skin of the stainless steel adaptor, then drill through the outer skin, and secure with three self tapping screws,(not supplied)now fill any gaps between the liner and outer skin of adaptor with fire cement, (note: do not push fire cement inside the cavity before liner is inserted as will block the drainage holes) lastly push the bottom of the adaptor inside the flue pipe and seal with fire cement.
Register Plate Adaptor Push the bottom end of ultraflex liner into the cavity between the inner and outer skin of the stainless steel adaptor, then drill through the outer skin, and secure with three self tapping screws,(not supplied)now fill any gaps between the liner and outer skin of adaptor with fire cement,(note do not push fire cement inside the cavity before liner is inserted as will block the drainage holes, the attached square plate can now be secured in place, now attach your single skin pipe to the underside of the adaptor and seal with fire cement.
Sump Adaptor Drill some holes through the circular ring and abut to underside of clay liner, (normally cast in concrete slab) mark positions of fixing holes to concrete and drill. Now apply sealant to circular ring and secure adaptor to underside of clay liner. (Fixings not supplied) now attach your single skin pipe to the underside of the adaptor and seal with fire cement.
Gather Unit Push the bottom end of ultraflex liner into the cavity between the inner and outer skin of the stainless steel adaptor, then drill through the outer skin, and secure with three self tapping screws, (not supplied) now fill any gaps between the liner and outer skin of adaptor with fire cement, (note do not push fire cement inside the cavity before liner is inserted as will block the drainage holes) lastly push the bottom of the adaptor inside the flue pipe and seal with fire cement. Now the liner will need to be pulled up the chimney whilst the gather unit is positioned, and secured in place.
18
Base Support Bracket Normally fixed at base of liner above register plate, and secured to wall. (fixings not supplied)
Register Plate The metal plate and supporting angle brackets will need cutting to size. Secure the brackets to the inside of the chimney (fixings not supplied) the single skin pipe from the appliance will need to pass through the adjustable centre plate.
Top plate Fitted with a top sleeve and clamp. With the flexible liner protruding from the top of the masonry chimney, feed the plate over the end of liner and place on top of brickwork cut the liner approximately 125 mm above the plate, insert the top sleeve. Now fit the clamp around the liner on top of the plate and tighten, (optional rain cap can be fitted) the plate will then need to be made watertight with sand and cement. Or finished off with a traditional chimney pot.
Top Insert i.e. protection sleeve, protects the flue liner termination, and should be fitted when supporting the liner from a top clamp, Basic cowl with or without mesh, first fit a top insert, then place rain cap base over outside of liner ,drill through the base and secure to liner with self tapping screws (not supplied)
Pot Hanger normally fitted to a chimney pot. With the liner protruding from the pot push the sleeve inside the liner, the three straps attached to the sleeve are then secured to the flexible liner with a fastening strap, now continue pushing the liner inside the pot until the base of the hanger rests on top, now bend the three outer straps down the outside of pot and secure with the second fastening strap, an optional anti downdraught cowl can be fitted, now or at a later date
Suspending Cowl With the liner protruding from the chimney pot push the sleeve inside the liner, the three straps attached to the sleeve are then secured to the flexible liner with a fastening strap, now continue pushing the liner inside the pot until the base of the suspending cowl rests on top, now bend the three outer straps down the outside of pot and secure with the second fastening strap,
Nose Cone tie a knot to your draw string (not supplied) pass string through hole in nose cone, tie a suitable weight to the end of draw string, now secure the cone to the bottom end of liner with duck tape etc, drop the draw string down the chimney and feed liner down .the nose cone will protect the end of liner and assist the installation.