316 0.6mm Stainless Steel
Condensing Appliances
Superior Grade Condensing Pipe
About FSM Group FSM is one of the leading Chimney & Flue manufacturers in the UK, producing around half a million quality steel products every year. FSM Group is a family-run company with over 40 years direct experience of selling chimney products to the UK chimney trade and retail sector. All our products have been selected from quality manufacturers and are trusted by trade installers across the UK. We believe our products should give you both value for money as well as peace of mind.
Good quality. Good price. What more could I want. Fitted next day, easily.
We have manufacturing
Quality Assurance All products are controlled by a Quality Assurance System certified to ISO 9001:2000. 2
Product Designation and Testing BSRIA Test report no. 19193/5 316 0.6mm product designations:
Designation EN 1856-1 T600 N1 D V2L50040 G100 EN 1856-1 T400 N1 W V2L50040 G50 EN 1856-1 T200 P1 W V2L50040 O00
The 316 flue pipe has been independently tested at BSRIA and complies with the specific requirements of BS EN 1856-1 and BS EN 1856-2 in accordance with the general requirements of BS EN 1443-2003.
OUR COMMITMENT WE NEVER COMPROMISE ON QUALITY
Product The 316 flue pipe is a range of prefabricated Stainless Steel Single Wall flue and vent systems. The 316 grade stainless steel 0.6mm product has a dull 2B finish. Lengths and fittings have a quick and easy to use socket and spigot jointing system. Optional locking bands are used to secure the joints on site.
Size Range Available in 100mm (4”) - 750mm (30”). All products can be powder coated to most BS or RAL Colour Code.
Condensing With Joint Condensing Seal added (T<200°C)
facilities across the UK , supplying premium products around the country.
Applications The 316 stainless steel is designed primarily for solid fuel boilers and stoves. This product is also suitable for use on commercial applications. 3
LengthsEW-ECO
e 1000
Length Módulo recto Élément droit Length Elemento lineare Módulo recto 1000mm 1000 mm Élément 500 mm droit 500mm Elemento 250 mm lineare
1000
ø
ø
ø 500
250mm
250
500
Plain Lengths
250
500
1000
250
1000 mm EWEC13 150 500 180 mm 200 250 300 350 400 450 500 550 600 650 700 750 800 ø EWEC14 ø 250 mm ø EWEC15
EWEC1380 100 130 150 180 200 250 300 350 400 450 500 550 600 650 700 750 800 Ø ø EWEC14 ø 4” 5” 6” 7” 8” 10” 12”ø 14” 16” 18” 20” 22” EWEC15
ø
Ø
80
100
100
130
130
150
150
180
200
250
300
350
400
450
500
550
180 200 250 300 350 400 450 500 550 600 650 700 750 800
24”
26”
28”
30”
600
650
700
750
24”
26”
28”
30”
600
650
700
750
ral drain Lengthlateral with lateral drain n desagüe Módulo recto con desagüe lateral ec purge latérale Élément droit avec purge latérale o condensa laterale Length with lateralcondensa drain Elemento scarico laterale
Length With Drain G
250
250
Módulo recto con desagüe lateral 250 mm droit avec purge latérale Élément Elemento scarico condensa laterale
G
Ø
130
G
150
180 200 250 300 350 400 450 500 550 600 650 700 750 800
1/2“
1“
ø
180 200 250 300 350 400 450 500 550 600 650 700 750 800 Ø G
80
ø
4” 130 5”150 180 6” 2007”250 300 8” 350 10” 14” 16” 18” 20” 22” 1“ 400 12” 450 500 550 600 650 700 750 800 100 130 150 180 200 250 300 350 400 450 500 550 1/2“ 1“
100
G
12.7
25.4
Adjustable length Módulo recto regulable Élément droit réglable Adjustable length regolabile Elemento lineare th Módulo recto regulable 400 – 560droit mm réglable gulable Élément 560 – 920 mm Elemento lineare regolabile églable 400 - 560mm
400-560
Adjustable length
400-560
EWEC544 e regolabile 400 – 560 560 - mm 920mm EWEC545
400-560
ø
ø
560-920
560 – 920 mm
Designed to fit into a standard length to form an adjustable length. It is NON load EWEC544 bearing EWEC545 80 100 130 150 180 200 250 300 Ø
560-920
2“
ø 100
560-920
150
80
350 400 450 500 550 600 650 700 750 800 ø
Ø
2
80
ø
150
G
ø 95
EWEC15D
250
250 mm
95
95
EWEC15D
2180 4
100
4”
100
130
150
5”
130
ø
180 200 250 300 350 400 450 500 550 600 650 700 750 800
6”
7”
8”
150
180
200
ø
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
250
300
350
400
450
500
550
600
650
700
750
ø
200 250 300 350 400 450 500 550 600 650 700 750 800
Lengths & Inspection Length
With Measuring Adaptor Length With Measurement Adaptor is used for checking the chimney draught, flue temperature & combustion efficiency of the heating appliance.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Inspection Length
With Door 200 pa (P)
Length to be used internally to achieve required height and easy access for cleaning.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
100
100
130
130
130
130
130
130
200
200
200
200
200
200
200
200
B
360
360
360
360
360
360
360
360
500
500
500
500
500
500
500
500
Draft Damper Length to be used to control the draft within the chimney.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
101
107
111
117
121
132
142
152
163
173
184
194
204
214
225
235
5
Elbows 15° Elbow To provide a 15° change in direction.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
87
89
90
92
93
97
100
103
106
110
113
116
120
123
126
130
30° Elbow To provide a 30° change in direction.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
93
98
100
104
107
114
120
127
134
140
147
154
161
168
175
182
45° Elbow To provide a 45° change in direction.
6
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
101
107
111
117
121
132
142
152
163
173
184
194
204
214
225
235
Elbows & Regulator 90° Elbow To provide a 90° change in direction.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
-
-
A
158
174
183
198
208
233
258
283
308
333
358
383
408
-
-
-
87° Elbow To provide a 87° change in direction.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
-
-
-
A
155
169
179
193
203
227
250
274
298
322
345
369
393
-
-
-
Draft Stabiliser The adaptor fits into the branch of the 90° Tee, It is used to control excess draft for oil/solid fuel/ biomass.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
7
Tee’s 87° Tee The tee pieces come complete with locking bands, allowing access to the system for sweeping and inspection.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
330
330
330
380
380
450
500
600
600
610
660
710
760
810
860
910
B
162
162
161
185
185
218
242
291
290
293
317
341
364
389
413
437
C
168
168
169
195
195
232
258
309
310
317
343
369
396
422
448
475
90° Tee The tee pieces come complete with locking bands, allowing access to the system for sweeping and inspection.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
300
330
350
380
400
450
500
550
600
650
700
750
800
850
900
950
24”
26”
28”
30”
135° Tee The tee pieces come complete with locking bands, allowing access to the system for sweeping and inspection.
8
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
361
404
432
475
503
574
644
715
786
856
927
998
1068
1138
1208
1278
B
130
137
141
147
151
162
172
182
193
203
214
224
234
245
255
265
C
231
267
291
328
352
412
472
533
593
653
713
774
834
894
954
1015
Tee Caps Tee Cap Allows access to the system for sweeping and inspection.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Tee Cap With Drain
Allows access to the system for sweeping and inspection and drainage.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Tee Cap With Side Drain Allows access to the system for sweeping and inspection and drainage.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
9
Adaptors Male Boiler Adaptor
Used to increase from biomass system to 316 0.6mm flue system.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Female Boiler Adaptor
Used to increase from biomass system to 316 0.6mm flue system.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Single to Twin
Adaptor
Used to adapt from single skin stove pipe to the twin-wall system.
9
10
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
-
-
-
-
-
-
-
-
-
-
-
A
150
180
200
230
250
-
-
-
-
-
-
-
-
-
-
-
Adaptors & Supports Twin Wall To Single
Adaptor
Used to adapt from the twin-wall system to 316 0.6mm flue system.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
-
-
-
-
-
-
-
-
-
-
Swivel Ring Used to attach to the ceiling for additional support..
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Wall Support
Adjustable
Used for additional support at any point of the external installation.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
B
215
225
245
275
295
345
395
445
495
545
595
645
695
745
795
845
C
295
305
325
355
375
425
475
525
575
625
675
725
775
825
875
925
D
325
265
265
295
310
360
410
460
510
560
610
660
710
760
810
860
11
Supports Wall Bracket
Adjustable 50 - 75mm Used to provide lateral support for a 316 0.6mm system can be used for internal and external walls.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
-
-
-
-
-
-
A
110
130
146
164
181
217
252
287
346
358
-
-
-
-
-
-
-
-
-
-
-
-
65
70
85
95
115
150
185
220
280
292
-
-
-
-
-
-
B C
50-80
Wall Band
Adjustable 50 - 150mm Used to provide lateral support for a 316 0.6mm system can be used for internal and external walls.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
-
130
150
180
200
250
300
350
400
450
500
550
600
650
700
-
A
-
240
260
285
310
340
360
410
460
510
560
610
660
710
760
-
B
-
225
225
225
265
265
265
325
325
325
400
400
400
430
475
-
Wall Band
Adjustable 150 - 250mm Used to provide lateral support for a 316 0.6mm system can be used for internal and external walls.
12
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
-
130
150
180
200
250
300
350
400
450
500
550
600
650
700
-
A
-
240
260
285
310
340
360
410
460
510
560
610
660
710
760
-
B
-
325
325
325
365
365
365
425
425
425
500
500
575
575
575
-
Supports Wall Band
Adjustable 250 - 350mm Used to provide lateral support for a 316 0.6mm system can be used for internal and external walls.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
-
130
150
180
200
250
300
350
400
450
500
550
600
650
700
-
A
-
240
260
285
310
340
360
410
460
510
560
610
660
710
760
-
B
-
425
425
425
465
465
465
525
525
525
600
600
675
675
675
-
Wall Support Bracket Used for additional support at any point of the external installation.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
A
-
-
-
260
280
330
380
430
480
530
580
630
680
730
780
-
B
-
-
-
140
150
175
200
225
250
275
300
325
350
375
400
-
C
-
-
-
180
190
215
240
265
290
315
340
365
390
415
440
-
Wall Sleeve Wall Sleeve designed to go straight through the wall to shield the flue from coming into contact with combustible material.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
130
160
180
210
230
280
330
380
430
480
530
580
630
680
730
780
13
Flashings Flashing
5° - 25° (Lead Based) The lead-based flashings (with stainless steel upstand) act as weatherproofing for the system when used externally through a roof.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
130
160
180
210
230
280
330
380
430
735
785
480
535
585
635
685
B
750
1000
1100
1200
1300
1400
1500
B’
1000
1200
1200
1300
1400
1400
1500
Flashing
25° - 45° (Lead Based) The lead-based flashings (with stainless steel upstand) act as weatherproofing for the system when used externally through a roof.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
130
160
180
210
230
280
330
380
430
480
535
585
635
685
735
785
1000
1100
1200
1300
1400
1500
1200
1200
1300
1400
1400
1500
B
750
B’
750
1000
Flat Flashing
Steel
The stainless steel flashings act as weatherproofing for the system when used externally through a roof.
14
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
130
160
180
210
230
280
330
380
430
480
535
585
635
685
735
785
B
390
420
440
470
490
540
590
640
690
740
795
845
895
945
1000
1050
Terminals Storm Collar Storm collars deflect rain from the top of the lead flashing. Seal with silicone sealant.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Top Stub
With or Without Mesh The top stub will close off the installation at the top of the system.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
140
170
190
220
240
290
340
390
440
490
540
590
640
690
740
790
Rain Cap
With or Without Mesh These terminals are especially designed to fit the 316 0.6mm system providing protection against rain and other elements.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
200
230
250
300
350
500
600
700
800
-
-
-
-
-
-
-
B
75
125
200
-
-
-
-
-
-
-
H
155
205
280
-
-
-
-
-
-
-
15
Terminals All Weather Cowl These terminals are especially designed to fit the 316 0.6mm system providing protection against rain and other elements.
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
ø
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
øA
160
190
240
290
340
430
480
580
600
-
-
-
-
-
-
-
øB
200
250
300
350
400
500
550
650
700
-
-
-
-
-
-
-
C
185
235
310
-
-
-
-
-
-
-
D
105
155
230
-
-
-
-
-
-
-
Horizontal Terminal
With Or Without Mesh
Used to fit to the the flue system as a horizontal outlet and is secured by way of a locking band
ø
16
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Components Condensing Seal Used for condensing systems.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
Locking Band Gives additional support and secures the joints.
ø
4”
5”
6”
7”
8”
10”
12”
14”
16”
18”
20”
22”
24”
26”
28”
30”
100
130
150
180
200
250
300
350
400
450
500
550
600
650
700
750
17
Installation Guide Installing Your Product The 316 should be installed (a minimum of 3 x diameter) from any combustible materials, e.g. 125mm pipe should be 375mm from combustible materials. Can be used as a substitute for a flexible flue liner. The 316 stainless steel must only be used to connect from the appliance to an existing liner or twin wall insulated system. It must NOT be used externally and where there is a risk of combustibles being placed next to the chimney, the minimum distances to combustibles must be maintained whether by a permanent enclosure or shield. Please refer to the Document J Building regulations for more information. The 316 should be fitted with socket uppermost, spigot (male end) downward to avoid condensate escaping. Each joint should be sealed with fire cement or high temperature silicone sealant to ensure a gas tight fit. Where 316 single wall flue passes through a brick internal wall, it is recommended a wall sleeve is used around the pipe. Provision for sweeping and inspections must be made. The chimney diameter should never be reduced to less than the diameter specified by the appliance manufacturer. An increase in size may be required. Ensure that adequate air is available for combustion. Components must NOT be modified for safety reasons. A chimney notice plate and carbon monoxide detector must be installed in the building, preferably in the same room as the appliance. The installation must be commissioned by a registered installer in-line with the Building Regulations (Document J). If there are any leaks or issues with the system, it must not be used until the problems have been rectified. Provisions must be made for condensate drainage where appropriate. Please refer to the Document J Building regulations for more information.
18
19
ISO 9001 FS 576960
FSM Group, Unit 6-7, Link 20, Bellingham Way, Aylesford, Kent, ME20 7HD Tel: 0344 800 6586 Email: info@fsmgroup.co.uk Copyright 2021 FSM Group ©