Super Caddy Specifications
Process Fluid Type: Hydraulic and lubricating oils having a minimum flash point of 200 F (93 C) per ASTM D92 or 180 F (82 C) per ASTM D93.
Advertisement
Seal Compatibility: Nitrile seals: compatible with most mineral based oils.
Inlet Fluid Temperature: +160 F (66 C) MAX
Inlet Pressure: 14 HG to 15 PSIG (a positive inlet pressure may damage pump shaft seals and cause fluid loss)
Fluid Circulation Rate: 0-13 GPM (0-49 LPM)
Operating Viscosity: 1300 SUS (260 cSt) MAX
Electrical Power Requirements: 120 VAC, 1 Phase, 60 Hz, 19.5 Amp
Hose Connections:
Inlet: 1 NPT, Hose 15 with 3 x 1 304 SS wand
Outlet: ¾ NPT, Hose 15 with 3 x ¾ 304 SS wand
Electrical Control Box: NEMA 12 consolette containing PLC, variable speed drive, operation controls, indicator lights, particle counter display, water sensor display, USB connection
Motor: 1 HP, 90 VDC Variable Speed
Pump: Marzocchi external gear pump, 1.713 cubic inch displacement; flow rate to 13 gpm at 1750 rpm; 125 psi internal relief valve
Wheels: 10-inch pneumatic wheels
Particle Filter: Pall Ultipleat® SRT filter particle removal filter assembly. Particle filter removal rating: x(c)=1000
Water Removal Filter: Pall PallSorbTM water removal filter assembly. Filter element removes free water.
Particle Counter: Laser particle transducer and display for measuring particle contamination; reports data (at 5 minute intervals) as ISO 4406 cleanliness code. Download results to a PC via USB connection.
Water Sensor: Monitors dissolved water content in system fluid and displays measurement as percent of fluid saturation.