Fire Cable Range



FireSense is a specialist supplier of Fire Alarm Systems and Fire Cable to installers, wholesalers and service companies. With decades of experience, FireSense is an expert in the fire industry.
Our mission is to keep society safe through quality fire solutions. We are 100% Australian owned and operated, priding ourselves on Quality, Expertise and the highest levels of Service.
We have been independently audited and awarded Triple ISO accreditation and certification in Quality, Environment and OH&S.
We partner to deliver excellence when & where it counts. Making Complex Easier.













The FireSense Difference
FireSense promises quality, expertise and the highest level of service. With over 90 staff across three branches, FireSense focuses on our customers’ needs to make delivering projects easier.




Large Stock Holdings
We hold substantial inventory of the FireSense cable range across the country, and in each of our branches, to ensure that we can supply quickly and efficiently to meet our customers’ needs.
Fire Cable Specialists
With decades of industry experience and knowledge, FireSense Cables are designed by experts to meet the current and future needs of the fire, electrical, and mechanical industries. We provide relevant, expert advice - not just a sales service.
Technical Knowledge
We have a team of experienced cable specialists providing personalised support for every customer, offering guidance on product selection, technical specifications, understanding project requirements, and expertise in compliance standards.
Project Coordination
Our team focuses on all details and creates personalised plans to meet project requirements, ensuring high levels of service and ease on site, i.e. document control, project summaries, custom drum labels, and personalised delivery schedules.





Cable Cutting Service
Many of our cables can be cut in our Sydney warehouse to the exact lengths your project requires, helping to streamline installation, reduce material waste, and save time on site.

High Quality Cable Drums
We utilise high quality timber and plastic drums that protect cables with exceptional strength and durability, ensuring safe delivery and easy management on site.
State Branches & Warehouses
FireSense have branches in Sydney, Melbourne & Brisbane to ensure local staff are available to assist customers with a personalised service and to ensure easy and reliable access to stock.
Direct Delivery to Site
FireSense owns & operates a large fleet of GPS tracked specialist delivery vehicles, offering multiple deliveries per day from all branches directly to any metro warehouse or site.
End of Life Recycling
Committed to comply with the Green Building Council Guidelines and cable recycling, at end of life, we will accept used FireSense TPS cables and will process both the PVC and the copper for recycling.



Fire Cable Project Highlights




75km of FireSense Fire Rated cable supplied. Halogen Free TPS, 2HR FR Fire Alarm, Control, Single Core & Multicore Servicing Fire Alarm, EWIS/PA, 240 VAC essential services, VSDs & tunnel PA systems
Custom made Screened Steel Wire Armour Fire Rated Cable supplied for rodent protection in tunnels
175km of 2HR Fire Rated Detection Cable used for tunnel detection systems
51km of custom made 2 and 4 Pair Individually and Overall Screened to meet signalling requirements
10km of 2HR Fire Rated LSZH Multicore and Single Core Cable supplied for power distribution & lighting applications
Project supplied across three years
Custom made 2HR Fire Rated 0.75mm 4 Core Screened cable with black sheath and white numbered cores
Requirements included specific core colour configuration, WS51W approvals, and application of end caps
Coordinated delivery was supported through detailed cable drum labelling, and scheduling across multiple stations

58km of FireSense 2HR Fire Rated LSZH Multicore and e Power Cable, custom made in black sheath ed lead times contributed to contractor meeting adlines and schedules set by NSW Government Structured delivery programs, detailed cable drum labelling supported installation across multiple tunnel sections
Total supply exceeding $1M

of FireSense 2HR Fire Rated LSZH Multicore and Core Power cable
uted to contractor meeting Greenstar project ments via FireSense PVC Free third party certificates rovided on bulk high quality timber drums, enabling cutting to maximise usage and reduce wastage coordination with Tier 1 Contractor, included specific um labelling, scheduled deliveries to site to suit access over 6 months
Compliance
TPS FIRE ALARM
Mechanical protection - AS/NZS 3013
AS/CA S008 compliant
Conductors - AS/NZS 1125
Insulation & Sheath - AS/NZS 3808
Markings - AS/NZS 1670:2018
Bureau Veritas - PVC Best Practice certified
Vinyl Council of Australia / Green Building Council of Australia
*Refer to technical datasheet for certificate numbers








WSX1
WSX1
WSX1
WSX1
Fire&MechanicalProtection-AS/NZS3013,AS/NZS4507(RHE-3)
CableConstruction-AS/NZS5000.2
TPS FIRE ALARM - HALOGEN FREE
ACMACompliance-AS/CAS008
Conductors,Insulation&Sheath-AS/NZS1125,AS/NZS3808
VerticalFlameSpread-AS/NZS1660.5.1(Sec6-CatC-AS/NZSIEC603
SmokeDensity-AS/NZS1660.5.2,AS/NZSIEC61034
HalogenGas-AS/NZS1660.5.3,AS/NZSIEC60754-1
AcidityofGases-AS/NZS166054,AS/NZSIEC60754-2
VerticalFlamePropagation-AS/NZS1660.5.6,AS/NZSIEC60332-1
BureauVeritas-PVCFree
*Refer to technical datasheet for certificate numbers



TPS FIRE ALARM - HALOGEN FREE



Available on 500m drums
WSX1
WSX1
WSX1
2HR FIRE RATED FIRE ALARM
Compliance
Fire & Mechanical Protection - AS/NZS 3013, AS/NZS 4507 (RHE-3)
Cable Construction - AS/NZS 5000.2
ACMA Compliance - AS/CA S008
Conductors, Insulation & Sheath - AS/NZS 1125, AS/NZS 3808
Vertical Flame Spread - AS/NZS 1660.5.1 (Sec 6 - Cat C - AS/NZS IEC 60
Smoke Density - AS/NZS 1660.5.2, AS/NZS IEC 61034
Halogen Gas - AS/NZS 1660.5.3, AS/NZS IEC 60754-1
Acidity of Gases - AS/NZS 1660.5.4, AS/NZS IEC 60754-2
Vertical Flame Propagation - AS/NZS 1660.5.6, AS/NZS IEC 60332-1
Bureau Veritas - PVC Free
RCM / Global Mark Certificate of Suitability





2HR FIRE RATED FIRE ALARM









Available on 250m or 500m drums. Can be cut to length for project.
WS51W
WS52W
WS52W
2HR FIRE RATED FIRE ALARM
The below cables were custom made for infrastructure road tunnel and rail projects, and are now available as a standard FireSense cable stock item - MOQ’s may apply.



Cable is cut to length per project.
Compliance
Fire & Mechanical Protection - AS/NZS 3013, AS/NZS 4507 (RHE-3)
2HR FIRE RATED CONTROL
Cable Construction - AS/NZS 5000.2
ACMA Compliance - AS/CA S008
Conductors, Insulation & Sheath - AS/NZS 1125, AS/NZS 3808
Vertical Flame Spread - AS/NZS 1660.5.1 (Sec 6 - Cat C - AS/NZS IEC 6
Smoke Density - AS/NZS 1660.5.2, AS/NZS IEC 61034
Halogen Gas - AS/NZS 1660.5.3, AS/NZS IEC 60754-1
Acidity of Gases - AS/NZS 1660 5 4, AS/NZS IEC 60754-2
Vertical Flame Propagation - AS/NZS 1660.5.6, AS/NZS IEC 60332-1
Bureau Veritas - PVC Free
RCM / Global Mark Certificate of Suitability





2HR FIRE RATED CONTROL




Cable is cut to length per project.

Approvals&Compliance
2HR FIRE RATED MULTICORE
Fire & Mechanical Protection - AS/NZS 3013, AS/NZS 4507 (RHE-3)
Cable Construction - AS/NZS 5000.1
ACMA Compliance - AS/CA S008
Conductors, Insulation & Sheath - AS/NZS 1125, AS/NZS 3808
Vertical Flame Spread - AS/NZS 1660.5.1 (Sec 6 - Cat C - AS/NZS IEC 6
Smoke Density - AS/NZS 1660.5.2, AS/NZS IEC 61034
Halogen Gas - AS/NZS 1660.5.3, AS/NZS IEC 60754-1
Acidity of Gases - AS/NZS 1660.5.4, AS/NZS IEC 60754-2
Vertical Flame Propagation - AS/NZS 1660.5.6, AS/NZS IEC 60332-1
Bureau Veritas - PVC Free
RCM / Global Mark Certificate of Suitability





* Indent item
2HR FIRE RATED MULTICORE




0 6/1kV voltage rating
-25°C to +110°C operating temperature
2HR FIRE RATED SINGLE CORE
10 x cable diameter minimum bending radius
Approvals&Compliance
Fire & Mechanical Protection - AS/NZS 3013, AS/NZS 4507 (RHE-3)
Cable Construction - AS/NZS 5000.1
ACMA Compliance - AS/CA S008
Conductors, Insulation & Sheath - AS/NZS 1125, AS/NZS 3808
Vertical Flame Spread - AS/NZS 1660.5.1 (Sec 6 - Cat C - AS/NZS IEC 60
Smoke Density - AS/NZS 1660.5.2, AS/NZS IEC 61034
Halogen Gas - AS/NZS 1660.5.3, AS/NZS IEC 60754-1
Acidity of Gases - AS/NZS 1660.5.4, AS/NZS IEC 60754-2
Vertical Flame Propagation - AS/NZS 1660.5.6, AS/NZS IEC 60332-1
Bureau Veritas - PVC Free
RCM / Global Mark Certificate of Suitability





* Indent item
2HR FIRE RATED SINGLE CORE


Lug Selection
FireSense Single Core cables use Class 6 flexible conductors When selecting lugs, the overall conductor diameter must be considered—particularly for cable sizes ≥240 mm² where strand counts increase significantly.

Cable is cut to length per project.
LSZH FLEXIBLE EARTH
Suited to meet Green Building Council of Australia (GBCA) requirements where cable being installed must be halogen free.
Features
PVC Free - Low Smoke Zero Halogen 110°C continuous operation
Flame retardant
Flexible, easy to strip, install & terminate
Class 6 Flexible conductors (≥10mm)
RCM certified
Environmentally friendly meeting GBCA requirements
PVC Free certified - Bureau Veritas & GECA
Technical Specifications
Stranded annealed copper conductors
Flame retardant PVC Free LSZH
X-HF-110 insulation
0.6/1kV voltage rating
Green and yellow sheath
-25°C to +110°C operating temperature
Compliance
Conductors & Insulation - AS/NZS 1125, AS/NZS 3808, AS/NZS 1660.1, 1660.2, 1660.3, 1660.4
Cable Construction - AS/NZS 5000.1, AS/NZS 3000:2007
Vertical Flame Spread - AS/NZS 1660.5.1 (Sec 6, Cat C, AS/NZS 60332-3-24)
Smoke Density - AS/NZS 1660.5.2, AS/NZS IEC 61034
Halogen Gas - AS/NZS 1660.5.3, AS/NZS IEC 60754-1
Acidity of Gases - AS/NZS 1660.5.4, AS/NZS IEC 60754-2
Vertical Flame Propagation - AS/NZS 1660.5.6, AS/NZS IEC 60332-1
Bureau Veritas - PVC Free
RCM / Global Mark Certificate of Suitability




* Indent item


Cable is cut to length per project.
2HR FIRE RATED CUSTOM CABLE
FireSense can produce high quality custom cables to meet your project needs. Our specialist team will work with you to understand your cable and project requirements and will oversee the development and manufacturing process, ensuring the most stringent quality standards are achieved.
Custom cables are indent items and lead times will apply. FireSense cables have all relevant certifications and approvals and are independently certified.





2HR FIRE RATED CUSTOM CABLE
FireSense custom cables are specified to meet your project requirements. Each option is designed to enhance performance, durability, and protection in real-world conditions. Examples of custom made cables include:-
Individually Screened Pairs & Overall Screened
Reduces electrical interference for sensitive systems
Ideal for audio, data, or signalling applications requiring high noise immunity
Sheath Colour
Alternate colours to suit project requirements & specifications eg black
Option to include identification markings eg white stripe
Steel Wire Armour Protection
Protects against rodents and mechanical damage
Ideal for areas of high concern & where cable integrity is critical
Black Nylon Protection
Provides termite and insect resistance
To manufacture the Steel Wire Armour and/or Black Nylon cable, the base cable is first selected, then the protective layer is applied, followed by a final outer layer of Low Smoke Zero Halogen sheath.




ACCESSORIES











materialsreleaseminimalsmokeandnotoxicgases,providingclearvisibilityan highriskareassuchasundergroundtunnels.
Terms & Definitions
WSX1-theminimummechanicalprotectionacablemustadheretoinorderto firealarminstallations.AdoptedinAS/NZS1670.1:2024tosetabaserequirem cablesandtheirmechanicalprotection.
V-90-PVCmaterialwithmaximum90ºCoperatingtemperature Applicableto cableinsulation&sheath.
X-HF-110-LSZHmaterialwithmaximum110ºCoperatingtemperature Applica FireRatedinsulation.
HFS-110-TP-LSZHmaterialwithmaximum110ºCoperatingtemperature App ourFireRatedsheath.
UVStabilised-Astabiliserisaddedtotheresinofasubstanceiecablesheathw protectsitfromlongtermdegradationfromUVlightegsunlight.
functionfor2hoursinafiresituation.Theoutersheathisformechanicalprotec
IsyourFRcableUVstabilised?
Yes.Theoutersheathofthefireratedcableisconstructedwithhalogenfreec polymersthatareUVstabilised.Theconstructionofthecableisinaccordance relevantstandards Fadingcanoccurwhenexposedtodirectsunlight,however doesn’taffectthemechanicalpropertiesofthecable.
WhatdoesWS52Wmean?*
AS/NZS3013coverstheFire&Mechanicalperformanceofwiringsystemelem electricalinstallations.AWS52WratingindicatesthatALLelementsofacablin havebeentested,andhavepassedthetests,definedinAS/NZS3013relatingt Resistance,ImpactResistance&WaterSprayResistance Thesetestsensure systemwillmaintaincircuitintegrityunderfireconditionsforaspecifiedtimep frommechanicalimpactsduringnonfireconditions. *Seediagramandexplanationonpage32.
What is WS52W?
AS 1670.1 calls for cable with increased fire and mechanical protection. AS/NZS 3013 covers the fire and mechanical performance of wiring systems for electrical installations and stipulates the tests required to achieve compliance.
These tests ensure that a cabling system will maintain circuit integrity under fire conditions for a specified time period and from mechanical impacts during non-fire conditions.
Tests classify 3 elements with a rating, ‘WSxxx’, e.g. WS51W or WS52W measuring:
• Fire Resistance
• Impact Resistance
• Water Spray Resistance
5 Fire Resistance
The fire resistance test subjects cables to intense heat and flame conditions designed to simulate real fire scenarios.
2 Impact Testing
This represents the degree of mechanical impact and cutting force that a cable can be subjected to without failure when operating a maximum allowable continuous operating temp (i.e. 110°C).
Most mechanical services standards will require a WS52W cable as a minimum. WS51W cables cannot be used in applications where WS52W is required.
W Water Spray Resistance
Once the cable has been tested in the fire resistance test for 120mins/2hrs, the cable is then subjected to simulate a sprinkler in a true condition.


Certifications
Product certifications are essential to ensure compliance. You can trust the team at FireSense understands this, and work hard to ensure all products have best in class certifications.




FireSense 2HR Fire Rated Cables are ActivFire certified and are the only FULL range of ActivFire certified cable in Australia.
FireSense is Triple ISO accredited and certified in Quality, Environment and OH&S.
FireSense cables have RCM / Global Mark Certificates of Suitability and are compliant with all electrical regulations.