VE
RS
IO
N
1.0
20 21
INSULATION FIXINGs GUIDE
WE HAVE A RANGE OF PROMOTIONAL FLYERS AND INFORMATIVE HAND OUTS also AVAILABLE
Sales and Customer Service Tel: +44 (0) 141 647 7100 Fax: +44 (0) 141 647 5100 Email: sales@evolutionfasteners.co.uk
C O N T E N T S
INSULATION FIXINGS
PAGE
SELF DRILLING INSULATION SCREWS - PHILLIPS/TORX
6
SELF-DRILLING INSULATION SCREWS – A4 STAINLESS STEEL
7
INSULATION ANCHORS
8
HEAVY DUTY ROOFING SCREWS
9
COMPOSITE PANEL - TEK® 3
10
A2/A4 STAINLESS COMPOSITE SCREWS
11
A4 BI-METAL MASONRY SCREW
12-13
SELF TAPPING MASONRY SCREW
14-15
CEMENTITIOUS BOARD SCREWS
16
TIMBER TEK
17
A2 STAINLESS BI-METAL WING-DRILL TEK SCREW
18
SELF-DRILLING CEMENTITIOUS BOARD SCREW
19
STRESS PLATES
20
INSULATION RETAINING WASHERS
21
PANEL-FIX
22
4
C O N T E N T S
TECHNICAL INFORMATION SPECIFICATIONS AND LABORATORY SERVICES
FIXING FINDER FIXING INSULATION PRODUCTS TO STEEL AND TIMBER SUBSTRATES IN INTERNAL AND EXTERNAL APPLICATIONS
PIR, PUR, XPS, EPS, PF AND PE INSULATION BOARDS GLASS, ROCK, STONE AND MINERAL WOOL ROLLS, BATTENS, MATTRESSES AND BOARDS FIXING STRUCTURAL, TRAPEZOIDAL, INSULATION PANELS WITH STEEL OR ALUMINIUM FASCIA’S FOR WALLS, ROOFING AND CLADDING
INDEX
PAGE
24-25
PAGE
26-44
26-31 32-33 34-44
46-47
E&OE
HOW TO USE THIS GUIDE
ICON KEY
BRICK
CONCRETE
STEEL
TIMBER
SOFFIT INSULATION RETENTION
GLASS AND MINERAL WOOL INSULATION SYSTEMS
WARM ROOF AND DEEP INSULATION SYSTEMS
EXTERNAL WALL INSULATION (EWI) SYSTEMS 5
INSULATION FIXINGS
Self Drilling Insulation - Phillips/Torx
Product Range Designed For:
Fixing insulation to steel and timber purlins
Head Style:
Phillips 2/Torx 25
Drive:
Single
Thread Form:
AISI C1022
Material Grade:
500hr Evoshield®
Coating:
Steel drilling capacity 0.7-2.0 mm
Recommended Drill Speed:
1,500 - 2,500 RPM
Technical Data Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
4.8mm
611.7HV
492.0HV
Ultimate Mechanical Performance Diameter
Tensile Strength
Shear Strength
4.8mm
11.23kN
7.7kN
Ultimate pull out values Diameter
Drill point
4.8mm
Tek 2
Steel Thickness 0.6mm
1.2mm
2.5mm
0.85kN
2.25kN
5.38kN
Ultimate pull out values (C16 grade timber) Diameter
Drill point
4.8mm
Tek 2
6
Phillips CODE
SIZE
BOX
IS60 IS80 IS100 IS110 IS120 IS130 IS140 IS150 IS160 IS170 IS180 IS190 IS200 IS220 IS240 IS260 IS280 IS300
4.8 x 60mm 4.8 x 80mm 4.8 x 100mm 4.8 x 110mm 4.8 x 120mm 4.8 x 130mm 4.8 x 140mm 4.8 x 150mm 4.8 x 160mm 4.8 x 170mm 4.8 x 180mm 4.8 x 190mm 4.8 x 200mm 4.8 x 220mm 4.8 x 240mm 4.8 x 260mm 4.8 x 280mm 4.8 x 300mm
200 200 200 200 200 200 200 200 200 200 200 100 100 100 100 100 100 100
4.8 x 120mm 4.8 x 140mm 4.8 x 160mm 4.8 x 180mm 4.8 x 200mm
200 200 200 200 100
Torx T25IS120 T25IS140 T25IS160 T25IS180 T25IS200
Fixing Finder Pages - 28,29,32
Embedment depth 25.0mm
35.0mm
1.90kN
4.00kN
Tel: +44 (0)141 647 7100
Fax: +44 (0)141 647 5100
INSULATION FIXINGS
Self-Drilling Insulation Screws Bi-metal – A4 Stainless Steel Product Range Designed For:
Fixing insulation to light gauge steel or timber substrates. Also suitable where dissimilar metals are being used or superior corrosion resistance is required
Head Style:
Philips No. 2/ Bugle Head
Thread Form:
Coarse thread (Pitch = 1.8mm (approx.)
Material Grade:
SAE C1022 Carbon Steel – Drilling point AISI 316/ EN 1.4401 (A4) Stainless Steel – shank and head
Coating:
5µm electroplated Zinc.
Recommended Steel drilling capacity 0.7-2.0 mm Drill Speed: 1,500 - 2,500 RPM z
CODE
SIZE
BOX
A4IS45 A4IS60 A4IS80 A4IS100 A4IS120 A4IS140
4.8 x 45mm 4.8 x 60mm 4.8 x 80mm 4.8 x 100mm 4.8 x 120mm 4.8 x 140mm
100 100 100 100 100 100
A4IS160
4.8 x 160mm
100
A4IS180 A4IS200 A4IS240
4.8 x 180mm 4.8 x 200mm 4.8 x 240mm
100 100 100
1
Technical Data Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
4.8mm
492.8HV
482.3HV
2
Ultimate Mechanical Performance Diameter
Tensile Strength
Shear Strength
4.8mm
7.90kN
5.41kN
3
Ultimate pull out values Diameter
Drill point
4.8mm
Tek 2
Steel Thickness 0.6mm
1.2mm
2.5mm
0.78kN
2.07kN
4.71kN
Ultimate pull out values (timber) Diameter
4.8mm
Embedment depth
Drill point
25.0mm
35.0mm
Tek 2
1.76kN
3.83kN
sales@evolutionfasteners.co.uk
Fixing Finder Pages - 30,31,33
www.evolutionfasteners.co.uk
7
INSULATION FIXINGS
Insulation Anchors Galvanised Insulation Anchors / A2 Stainless Steel Insulation Anchors
Product Range CODE
SIZE
BOX
80mm 90mm 110mm 140mm 170mm 200mm 240mm
50 50 50 50 50 50 50
Galvanised GIA 880 GIA 890 GIA 8110 GIA 8140 GIA 8170 GIA 8200 GIA 8240
Designed For:
Fixing rigid insulation boards and mineral wool insulation to blockwork, brickwork or concrete substrates in C1 and C2 internal corrosion environments
Head Style:
40mm ØD compression disk
Material Grade:
SAE 1080 spring steel (non-hardened)/ AISI 304 / EN 1.4301/ A2-70 stainless steel
Coating:
HD Galvanised - Z140 (pursuant to EN 10346)/None
Fire Classification:
A1 (pursuant to EN 13501-1)
A2 Stainless Steel A2GIA110 A2GIA140 A2GIA170
110mm 140mm 170mm
50 50 50
Technical Data Pull Out Data Embedment Depth (Mm)
8
Product code
Nominal Diameter (mm)
35.00
40.00
45.00
GIA80
08.00
0.7kN
0.7kN
1.0kN
GIA90
08.00
0.7kN
0.7kN
1.0kN
GIA110
08.00
0.7kN
0.7kN
1.0kN
GIA140
08.00
0.7kN
0.7kN
1.0kN
GIA170
08.00
0.7kN
0.7kN
1.0kN
GIA240
08.00
0.7kN
0.7kN
1.0kN
A2GIA110
08.00
0.7kN
0.8kN
1.0kN
A2GIA140
08.00
0.7kN
0.8kN
1.0kN
A2GIA170
08.00
0.7kN
0.8kN
1.0kN
Tel: +44 (0)141 647 7100
Fixing Finder Pages - 28 - 33 Fax: +44 (0)141 647 5100
INSULATION FIXINGS
Heavy Duty Roofing Screw
Product Range
Designed For:
Fixing insulation and single ply membrane to plywood, timbers, steel decking and concrete. *
Head Style:
Dome Head (Pan)
Drive:
PH3
Thread Form:
Coarse single thread
Material Grade:
AISI C1022
Coating:
500hr Evoshield®
Technical Data
CODE
SIZE
BOX
ERS76 ERS100 ERS127 ERS152 ERS176 ERS200 ERS225 ERS250
76 mm 100 mm 127 mm 152 mm 176 mm 200 mm 225 mm 250 mm
100 100 100 100 50 50 50 50
H EAVY DUTY, M ULTI-PURPOSE ROOFI NG SCREW
Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
5.5mm
581.1 HVO.3
438.8 HVO.3
Ultimate Mechanical Performance Diameter
Tensile Strength
Shear Strength
6.3mm
18.6kN
7.3kN
Ultimate pull out values (unfactored) Substrate Steel
Concrete (C35)
Thickness (mm)
Timber (C16)
Embedment (mm)
0.6
1.2
25.0
35.0
25.0
35.0
2.4kN
4.3kN
8.7kN
13.9kN
7.1kN
10.5kN
sales@evolutionfasteners.co.uk
CALL TO PLACE ORDER T: +44 (0)141 647 7100 E: sales@evolutionfasteners.co.uk
www.evolutionfasteners.co.uk
9
INSULATION FIXINGS
Composite Panel - TEK® 3 – 16mm/19mm Washer 1.2mm - 3.5mm Steel Thickness
Product Range CODE Designed For -
Fixing cladding and roofing applications to hot and cold rolled purlins/rails Fastening liner panels and general components to steel
Head Style -
Hexagonal
Drive -
5/16” hexagonal
Washer -
16mm/ 19mm Ø bonded EPDM
Thread Form -
Coarse thread (Tek 3)
Shank Material -
Carbon steel
Material Grade -
SAE C1022
Coating -
500Hr EvoShield®
Hardness Rating (Vickers scale) Surface Hardness
Core Hardness
5.5mm
550.0HV
465.0HV
16mm washer TSBWHT5.5-80-3
5.5 x 80mm
100
16mm
TSBWHT5.5-105-3
5.5 x 105mm
100
16mm
TSBWHT5.5-115-3
5.5 x 115mm
100
16mm
TSBWHT5.5-135-3
5.5 x 135mm
100
16mm
TSBWHT5.5-150-3
5.5 x 150mm
100
16mm
TSBWHT16-5.5-185-3
5.5 x 185mm
100
16mm
TSBWHT19-5.5-80-3
5.5 x 80mm
100
19mm
TSBWHT19-5.5-105-3
5.5 x 105mm
100
19mm
TSBWHT19-5.5-135-3
5.5 x 135mm
100
19mm
TSBWHT19-5.5-150-3
5.5 x 150mm
100
19mm
TSBWHT19-5.5-185-3
5.5 x 185mm
50
19mm
TSBWHT19-5.5-225-3
5.5 x 225mm
50
19mm
TSBWHT19-5.5-240-3
5.5 x 240mm
50
19mm
TSBWHT19-5.5-275-3
5.5 x 275mm
50
19mm
TSBWHT19-5.5-300-3
5.5 x 300mm
50
19mm
Composite Panel for Timber CODE
SIZE
BOX
TSBWHT6.3-80-GP
6.3 X 80mm
100
TSBWHT6.3-100-GP
6.3 X 100mm
100
TSBWHT6.3-125-GP
6.3 X 125mm
100
TSBWHT6.3-150-GP
6.3 X 150mm
100
Unfactored Mechanical Performance Diameter
Tensile Strength
Shear Strength
5.5mm
16.5kN
10.3kN
Pullover Performance Diameter
In 0.6mm steel
In 1.2mm steel
5.5mm
3.1kN
6.0kN
Ultimate pull out values
Fixing Finder Pages - 35 - 39
Steel Thickness
Diameter
Drill point
1.2mm
1.6mm
2.0mm
2.5mm
3.0mm
4.0mm
5.5mm
Tek 3
1.7kN
2.1kN
2.7kN
4.6kN
4.8kN
5.5kN
10
BOX WASHER SIZE
19mm washer
Technical Data
Diameter
SIZE
Tel: +44 (0)141 647 7100
Fax: +44 (0)141 647 5100
INSULATION FIXINGS
A2/A4 Stainless Steel Bi-metal Composite Panel 1.2mm - 3.5mm Steel Thickness
Product Range CODE
SIZE
BOX
WASHER SIZE
A2 BMHT12-5.5-105-3
5.5 x 105mm
100
12mm
Use in brick-tie channel systems and for fastening aluminium sheeting and panels
BMHT12-5.5-135-3
5.5 x 135mm
100
12mm
BMHT12-5.5-150-3
5.5 x 150mm
100
12mm
BMHT12-5.5-185-3
5.5 x 185mm
100
12mm
Head Style -
Hexagonal
BMTSBWHT5.5-80-3
5.5 x 80mm
100
16mm
Drive -
5/16” hexagonal
BMTSBWHT5.5-105-3
5.5 x 105mm
100
16mm
Washer -
16mm Ø bonded EPDM
BMTSBWHT5.5-135-3
5.5 x 135mm
100
16mm
BMTSBWHT5.5-150-3
5.5 x 150mm
100
16mm
Thread Form -
Coarse thread
Shank Material -
Stainless steel
Material Grade -
AISI 304/ EN 1.4301
Coating -
(A2) or AISI 316/ EN 1.4401 (A4) Electroplated zinc
Designed For -
BMTSBWHT5.5-165-3
5.5 x 165mm
100
16mm
BMTSBWHT16-5.5-185-3
5.5 x 185mm
50
16mm
BMTSBWHT5.5-185-3
5.5 x 185mm
50
19mm
BMTSBWHT5.5-235-3
5.5 x 235mm
50
19mm
BMTSBWHT5.5-275-3
5.5 x 275mm
50
19mm
A4BMHT105-3
5.5 x 105mm
100
16mm
A4BMHT135-3
5.5 x 135mm
100
16mm
A4BMHT150-3
5.5 x 150mm
100
16mm
A4BMHT185-3
5.5 x 185mm
100
19mm
A4
Technical Data Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
A2 Heavy Section Bi-Metal
5.5mm
465.6 HV0.3
323.7 HV0.3
BMTSBWHT5.5-105-5
5.5 x 105mm
100
16mm
BMTSBWHT5.5-125-5
5.5 x 125mm
100
16mm
BMTSBWHT5.5-150-5
5.5 x 150mm
100
19mm
BMTSBWHT5.5-185-5
5.5 x 185mm
50
19mm
BMTSBWHT5.5-245-5
5.5 x 245mm
50
19mm
Pullover Performance Diameter
In 0.6mm steel
In 1.2mm steel
5.5mm
2.4kN
8.1kN
Tek 5 range – unfactored pull out values Steel Thickness
Diameter
Drill point
4mm
5mm
6mm
8mm
10mm
12.5mm
5.5mm
Tek 5
6.4kN
7.7kN
10.1kN
11.4kN
12.3kN
12.8kN
Tek 3 range – unfactored pull out values
Fixing Finder Pages - 40 - 44
Steel Thickness
Diameter
Drill point
1.2mm
1.6mm
2.0mm
2.5mm
3.0mm
4.0mm
5.5mm
Tek 3
1.7kN
2.1kN
2.5kN
3.3kN
4.1kN
5.4kN
sales@evolutionfasteners.co.uk
www.evolutionfasteners.co.uk
11
INSULATION FIXINGS
A4 Bi-Metal Stainless Steel Masonry Screw Product Range CODE Designed For:
Fixing timber battens, trunking, track and general components into concrete, masonry and timber
SIZE
BOX QUANTITY
Hexagonal Headed A4HH6.3-32-GP
6.3mm x 32mm
100
Head Style:
5/16” hexagonal head/ Countersunk
A4HH6.3-45-GP
6.3mm x 45mm
100
A4HH6.3-57-GP
6.3mm x 57mm
100
Shank Material:
Stainless Steel
A4HH6.3-70-GP
6.3mm x 70mm
100
A4HH6.3-82-GP
6.3mm x 82mm
100
AISI 316/ A4
A4HH6.3-100-GP
6.3mm x 100mm
100
A4HH6.3-125-GP
6.3mm x 125mm
100
A4HH6.3-140-GP
6.3mm x 140mm
100
Material Grade:
Countersunk Headed
Technical Data
A4CSK6.3-45-GP
6.3mm x 45mm
100
A4CSK6.3-57-GP
6.3mm x 57mm
100
A4CSK6.3-75-GP
6.3mm x 75mm
100
Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
6.3mm
577.4 HV0.3
465.1 HV0.3
1
Unfactored Mechanial Performance Diameter
Tensile Strength
Shear Strength
6.3mm
18.7kN
8.9kN
Ultimate pull out loading from steel
2
Steel substrate (S275 JR mild steel) Major diameter
Steel thickness
Steel thickness
Steel thickness
6.3mm
0.7mm
1.0mm
1.2mm
Force
1.0kN
1.4kN
2.0kN
3
Ultimate pull out loading from timber Major diameter
Timber grade
Embedment depth
Load
6.3mm
C16
25.0mm
2.3kN
6.3mm
C16
35.0mm
3.7kN
Fixing Finder Pages - 30,33 12
Tel: +44 (0)141 647 7100
Fax: +44 (0)141 647 5100
INSULATION FIXINGS
Technical Data Ultimate Loading: Withdrawal Resistance (Concrete and Masonry Substrates) Embedment Depth (mm)
C25/30 Concrete (30N/mm2)
Aerated Concrete Block (7N/mm2)
Class A Engineering Brick (75 N/mm2)
25.0
2,850 N
650 N
3,690
35.0
6,890 N
1,010 N
9,670
Characteristic/ Safe Loading: Withdrawal Resistance (Concrete and Masonry Substrates, γ = 3.0) Embedment Depth (mm)
C25/30 Concrete (30N/mm2)
Aerated Concrete Block (7N/mm2)
Class A Engineering Brick (75 N/mm2)
25.0
950 N
210 N
1,230
35.0
2,290 N
330 N
3,220
Concrete and masonry setting information Substrate type
Category
Data
All
Nominal embedment depth
35.0mm
Non cracked concrete (>30N/mm2)
Minimum base material thickness Minimum screw spacing Minimum edge distance
100.0mm 55.0mm 55.0mm
Cracked concrete (>30N/mm2)
Minimum base thickness Minimum screw spacing Minimum edge distance
100.0mm 40.0mm 55.0mm
Influence of Compressive Strength on Withdrawal Resistance (Reduction Factors) Nominal Anchor Diameter (mm)
Drill Hole Diameter (mm
Embedment Depth (mm)
6.3
5.15
6.3
5.15
Compressive Strength – Cube (EN 1992) C20/25
C25/30
C30/37
C35/45
C40/50
C45/55
≥C50/60
25/0
0.6
1.0
1.0
1.0
1.2
1.2
1.3
35.0
0.7
1.0
1.1
1.2
1.3
1.4
1.5
Influence of edge distance on loadings (reduction factor) Percentage of stated minimum
10%
20%
30%
40%
50%
60%
70%
80%
90%
100%
Reduction factor
N/A
N/A
N/A
N/A
N/A
0.75
0.80
0.85
0.90
1.00
sales@evolutionfasteners.co.uk
www.evolutionfasteners.co.uk
13
INSULATION FIXINGS
Self Tapping Masonry Screw
Designed For:
Fixing timber battens, trunking, track and general components to concrete and masonry substrates
Head Style:
Countersunk or slotted hexagonal.
Material Grade:
SAE C1022 Carbon steel.
Coating:
EvoShield® 500Hr NSST resistant (Aluminium/ Zinc flake bound in resin).
Drive bit:
Phillips No. 2 or No.3 female socket, or, 5/16” hexagonal male socket (with slot).
Point:
Nail (pyramidal).
2
3 MSCSK
MSHH
1
Product Setting Details Substrate Type
Parameter
All types
Non-Cracked Concrete (> 20 MPa < 80 MPa)
Screw Nominal Diameter, dnom (mm) 4.8
6.3
Nominal Embedment Depth, h1 (mm)
25
25
Nominal Drill Hole Diameter, d0 (mm)
4.35
5.15
Clearance Hole Diameter, df (mm)
6
8
Installation Torque, τinst (Nm)
< 3.0
< 7.0
Minimum Member Thickness, hc (mm)
100
100
50
55
Minimum Member Thickness, hmin (mm)
100
100
Minimum Edge Distance, cmin (mm)
50
40
Minimum Spacing, smin (mm)
50
55
Minimum Edge Distance, cmin (mm) Minimum Spacing, smin (mm)
Cracked Concrete (> 20 MPa < 80 MPa)
14
Tel: +44 (0)141 647 7100
Fax: +44 (0)141 647 5100
INSULATION FIXINGS
Product Range Fixture Limitations CODE
Nominal Dimensions (mm)
Min. Thickness, tmin (mm)
Max. Thickness, tmax (mm)
6.3 x 32 6.3 x 45 6.3 x 57 6.3 x 70 6.3 x 82 6.3 x 100 6.3 x 125 6.3 x 140 6.3 x 160 6.3 x 180 6.3 x 200 6.3 x 254
0 0 0 30 45 55 75 80 100 120
7 20 32 45 57 75 100 105 125 145
140 190
165 215
4.8 x 32 4.8 x 45 4.8 x 57 4.8 x 70 4.8 x 82 4.8 x 100 6.3 x 32 6.3 x 45 6.3 x 57 6.3 x 70 6.3 x 82 6.3 x 100 6.3 x 125 6.3 x 150
0 0 0 30 45 55 0 0 0 30 45 55 75 100
7 20 32 45 57 75 7 20 32 45 57 75 100 125
Hexagonal Headed MSHH6.3-32-516 MSHH6.3-45-516 MSHH6.3-57-516 MSHH6.3-70-516 MSHH6.3-82-516 MSHH6.3-100-516 MSHH6.3-125-516 MSHH6.3-140-516 MSHH6.3-160-516 MSHH6.3-180-516 MSHH6.3-200-516 MSHH6.3-254-516 Countersunk Headed MSCSK4.8-32-2 MSCSK4.8-45-2 MSCSK4.8-57-2 MSCSK4.8-70-2 MSCSK4.8-82-2 MSCSK4.8-100-2 MSCSK6.3-32-3 MSCSK6.3-45-3 MSCSK6.3-57-3 MSCSK6.3-70-3 MSCSK6.3-82-3 MSCSK6.3-100-3 MSCSK6.3-125-3 MSCSK6.3-150-3
Fixing Finder Pages - 28 - 29
sales@evolutionfasteners.co.uk
www.evolutionfasteners.co.uk
15
INSULATION FIXINGS
Cementitious Board Screws
Product Range Designed For:
Fixing cementitious and other dense boards to timber and metal substrates
Head Style:
Double countersunk with nibs
Recess type:
Phillips No. 2
Thread Type:
Patent (pending) Evolution Universal Thread Carbon steel
Material Grade:
C1022
Coating:
1,000Hr EvoShield®
CODE
SIZE
EVOSHIELD COATING
BOX
WHX32
4.2 x 32 mm
200
WHX42
4.2 x 42 mm
200
WHX60
4.2 x 60 mm
200
WHX80
4.2 x 80 mm
200
WHX100
4.2 x 100 mm
200
WHL08114
4.2 x 32 mm
200
WHL08158
4.2 x 42 mm
200
Technical Data Bi-metal tip for attaching board to wood stud or metal stud
Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
4.2mm
553.6HV
414.0HV
Unfactored Mechanical Performance Diameter
Tensile Strength
Shear Strength
4.2mm
6.9kN
5.0kN
Unfactored pull out values (metallic substrate) Diameter 4.2mm
Drill Point Tek 2
Steel Thickness 1.2mm
1.8mm
2.5mm
1.6kN
1.9kN
3.8kN
High and low thread for stable driving Large wafer head with ribs allows good countersink and clamps the board firmly
Ultimate Pull Out Loads (kN) in C16 Timber Diameter 4.2mm
16
Embedment Depth 15mm
30mm
50mm
1.9 kN
2.7 kN
3.2 kN
Tel: +44 (0)141 647 7100
Fixing Finder Pages - 28
Fax: +44 (0)141 647 5100
INSULATION FIXINGS
Timber Tek
Product Range
Designed For:
Fixing timber or composites to steel
Head Style:
Countersunk ot countersunk with nibs
Drive:
Phillips® No. 2 or No. 3
Thread Form:
Coarse thread (Tek 3)
Shank Material:
Carbon steel
Material Grade:
SAE C1022
Coating:
Wing drill Tek 3 range - for light steel
500Hr EvoShield®
Technical Data Tek 3 range – Unfactored pull out values
CODE
SIZE
EFFECTIVE THREAD LENGTH
TSTF4.2-38-3
4.2x38mm
22mm
TSTF4.8-38-3
4/8x38mm
22mm
TSTF4.8-45-3
4.8x45mm
27mm
TSTF5.5-50-3
5.5x50mm
30mm
TSTF5.5-62-3
5.5x62mm
40mm
TSTF5.5-80-3
5.5x80mm
60mm
TSTF5.5-100-3
5.5x100mm
80mm
TSTF5.5-120-3
5.5x120mm
100mm
TSTF5.5-150-3
5.5x150mm
130mm
TSTF5.5-180-3
5.5x180mm
155mm
Wing drill Tek 4 range for medium gauge steel
Steel Thickness
4.2mm
Drill point Tek 3
1.0kN
1.2kN
1.9kN
3.5kN
3.9kN
4.8kN
4.8mm
Tek 3
1.1kN
1.5kN
2.5kN
3.6kN
3.9kN
4.4kN
5.5mm
Tek 3
TSTF6.3-60-4
6.3x60.0mm
FULL
1.2kN
2.3kN
3.0kN
4.0kN
4.6kN
5.7kN
TSTF6.3-85-4
6.3x85.0mm
FULL
Diameter
1.2mm
1.6mm
2.0mm
2.5mm
3.0mm 4.0mm
CODE
SIZE
EFFECTIVE THREAD LENGTH
Tek 4 range – Unfactored pull out values Diameter
Drill point
6.3mm
Tek 4
Steel Thickness 2.5mm
3.0mm
4.0mm
5.0mm
6.0mm
4.1kN
4.7kN
5.9kN
6.4kN
7.2kN
CODE
SIZE
EFFECTIVE THREAD LENGTH
TSTF5.5-42-5
5.5x42mm
13mm
Steel Thickness
TSTF5.5-65-5
5.5x65mm
28mm
TSTF5.5-85-5
5.5x85mm
50mm
TSTF5.5-100-5
5.5x100mm
65mm
Tek 5 range – Unfactored pull out values Diameter
Drill point
4.0mm
5.0mm
6.0mm
8.0mm 10.0mm 12.5mm
5.5mm
Tek 5
4.2kN
9.8kN
10.4kN
11.7kN
Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
4.2mm
582.6HV
477.8HV
4.8mm
570.0HV
474.1HV
5.5mm
592.1Hv
478.8HV
6.3mm
587.4 HV0.3
468.9 HV0.3
Wing drill Tek 5 range - for heavy steel
12.5kN
13.8kN
Ultimate Mechanical Performance Diameter
Tensile Strength
Shear Strength
4.2mm
10.4kN
5.2kN
4.8mm
12.4kN
6.4kN
5.5mm
20.1kN
10.3kN
6.3mm
22.7kN
15.2kN
sales@evolutionfasteners.co.uk
TSTF5.5-110-5
5.5 x 110mm
75mm
TSTF5.5-135-5
5.5x135mm
100mm
TSTF5.5-150-5
5.5x150mm
115mm
TSTF5.5-180-5
5.5x180mm
145mm
Fixing Finder Pages - 28,29,32
www.evolutionfasteners.co.uk
17
INSULATION FIXINGS
A2 Stainless Bi-Metal Wing-Drill Tek Screw
Product Range Designed For:
Bi-metal wing drill tek screw range – for light steel
Fastening when stainless steel product is required, e.g. in aluminium sheeting and panels
Head Style:
Countersunk
Drive:
Phillips® No. 2 or No. 3 or Torx® 25
Thread Form:
Coarse thread (Tek 3)
Shank Material:
Stainless steel
Material Grade:
AISI 304/ EN 1.4301 (A2) or AISI 316/ EN 1.4401 (A4)
Recommended Drill Speed:
1,500 - 2,500 RPM
CODE
SIZE
EFFECTIVE THREAD LENGTH
BMWD4.8-38-3
4.8x38mm
24.0mm
BMWD5.5-50-3
5.5x50mm
FULL
BMWD5.5-62-3
5.5x62mm
40.0mm
BMWD5.5-80-3
5.5x80mm
60.0mm
BMWD5.5-100-3
5.5x100mm
60.0mm
BMWD5.5-120-3
5.5x120mm
60.0mm
Bi-metal wing drill tek screw range– for heavy steel
Technical Data
CODE
SIZE
EFFECTIVE THREAD LENGTH
BMWD5.5-65-5
5.5x65mm
FULL
BMWD5.5-85-5
5.5x85mm
50.0mm
BMWD5.5-110-5
5.5x110mm
50.0mm
BMWD5.5-135-5
5.5x135mm
50.0mm
Head
Hardness Rating (Vickers scale) Diameter
Surface Hardness
Core Hardness
4.8mm
390.0HV
270.0HV
5.5mm
390.0HV
270.0HV
Pullover Performance
Ultimate Mechanical Performance Diameter
Tensile Strength
Shear Strength
Diameter
Substrate50mm timber
4.8mm
9.8kN
8.2kN
4.8mm
1.6kN
5.5mm
11.6kN
9.8kN
5.5mm
3.0kN
Threads
Wings
Tek 3 range – Unfactored pull out values
Point
Steel Thickness
Diameter
Drill point
1.2mm
1.6mm
2.0mm
2.5mm
3.0mm
4.0mm
4.8mm
Tek 3
1.9kN
2.7kN
3.5kN
4.5kN
5.0kN
6.3kN
5.5mm
Tek 3
2.0kN
2.4kN
3.6kN
4.3kN
5.1kN
6.7kN
Tek 5 range – Unfactored pull out values
Wings ream hole larger than threads so threads will not engage board.
Steel Thickness
Diameter
Drill point
4.0mm
5.0mm
6.0mm
8.0mm
10.0mm
12.5mm
5.5mm
Tek 5
4.5kN
5.9kN
7.3kN
8.9kN
10.7kN
11.9kN
18
Tel: +44 (0)141 647 7100
Winged Reamer
Wings break off when they hit steel, then threads engage to elevate board jacking
Fixing Finder Pages - 30,33
Fax: +44 (0)141 647 5100
Self-drilling Cementitious Board Screw
Product Range Designed For:
Fixing cementitious and other dense boards to timber and metal substrates
Head Style:
Double countersunk with nibs
Drive:
Phillips® No. 2
Thread Form:
Patent (pending) Evolution Universal Thread
Shank Material:
A2 / Carbon Steel
CODE
SIZE
BOX
BMDW4832
4.8 x 32 mm
200
BMDW4842
4.8 x 42 mm
200
BMDW4850
4.8 x 50 mm
200
BMDW4870
4.8 x 70 mm
200
Technical Data Bi-metal tip for attaching board to wood stud or metal stud
Ultimate Pull Out Loadings (kN) Steel Substrates (S275 JR Mild Steel) Major Diameter 4.8 mm
Steel Thickness (mm) 0.70
1.00
1.20
1.50
2.00
2.50
1.10 kN
1.20 kN
1.60 kN
1.80 kN
2.20 kN
3.60 kN
Timber Substrates Major Diameter
4.8 mm
Timber Grade C16 (soft wood)
Embedment Depth (mm)
Load (kN)
27.0
2.60
35.0
3.00
High and low thread for stable driving Large wafer head with ribs allows good countersink and clamps the board firmly
Fixing Finder Pages - 30
sales@evolutionfasteners.co.uk
www.evolutionfasteners.co.uk
19
INSULATION FIXINGS
Stress Plates
Galvanised / Stainless Steel
Product Range Galvanised Steel Designed For:
Spreading the loading when fixing membrane, insulation and single ply materials in roofing applications, preventing the material being fastened from pulling over the head of the fastener.
CODE
SIZE
BOX
SPR70
Round 70mm
100
SPR90
Round 90mm
100
SP082
Oval 82 x 40mm
100
SSSPR70
A2 Stainless Steel Round 70mm
100
A2PIW80
Round 80mm
100
Stainless Steel
Technical Data Stress Plate Nominal Dimensional Information Part Number
Form
Nominal Thickness (mm)
Nominal Dimensions (mm)
SPR70
Round
0.7
70.0 (diameter)
SPO82
Oval
0.7
82.0 x 40.0
Stress Plate Companion Fixing Finder Fixture Type
Rigid Insulation/ Single Ply Membrane
Substrate Type Masonry Thin Metal Purlin (<1.2mm) Thick Metal Purlin
Companion Product Range ERS
IS
(>1.2mm<3.5mm)
Fixing Finder Pages - 28 - 33 20
Tel: +44 (0)141 647 7100
Fax: +44 (0)141 647 5100
INSULATION FIXINGS
Insulation Retaining Washers
Product Range
CODE
Designed For: For securing insulation to timber and sheet steel when used with Evolution drywall, IS etc Product Nominal Technical Data
SIZE
DIAMETER
BOX
RW5
5 mm Recess
46 mm
500
RW18
18 mm Recess
46 mm
500
RW65
65 mm Recess
50 mm
400
RW105
105 mm Recess
50 mm
200
RW165
165 mm Recess
50 mm
200
EVNW35
35mm polyprop
35mm
1000
EVPPW50
50mm polyprop
50mm
1000
Head Diameter (mm)
Nominal Body Length (mm)
Extension to Fixing Length (mm)
Colour
RW5
46.0
5.0
2.0
White
ECW60
12 mm Recess
60 mm
100
RW18
46.0
18.0
13.0
Black
ECW90
Fits ECW60
90 mm
100
RW35
50.0
35.0
20.0
White
RW65
50.0
65.0
50.0
White
RW105
50.0
105.0
80.0
Red
RW165
50.0
165.0
140.0
Red
EVNW35
35.0
N/A
N/A
Black
EVPPW50
50.0
N/A
N/A
Black
ECW60
60.0
12.0
10.0
White
ECW90 * Used with ECW60
90.0
N/A
N/A P
White
code
Fixing Finder Pages - 28 - 31
sales@evolutionfasteners.co.uk
www.evolutionfasteners.co.uk
21
INSULATION FIXINGS
Panel-Fix
Insulation Fixing
Product Range Designed For:
Quick through-fix for insulation boards into masonry/ aerated concrete/ brick/ concrete/ stone
Head Style:
Flat
Shank Material:
Polypropylene
Material Grade:
Thermoplastic Polymer
Colour:
CODE
SIZE
FIXTURE THICKNESS
BOX
EVPF50
8.0 x 50 mm
10.0 - 20.0 mm
500
EVPF70
8.0 x 70 mm
10.0 - 40.0 mm
500
EVPF90
8.0 x 90 mm
10.0 - 60.0 mm
500
EVPF110
8.0 x 110 mm
10.0 - 80.0 mm
500
EVPF130
8.0 x 130 mm 10.0 - 100.0 mm
500
White
Technical Data Ultimate Pull Out Values Concrete
Solid Brick
Concrete Block
0.25kN
0.23kN
0.18kN
50mm
70mm
90mm
110mm
130mm
22
Tel: +44 (0)141 647 7100
Fax: +44 (0)141 647 5100
OUR NEW BOARD FIXING GUIDE IS ALSO AVILABLE NOW
CALL TO PLACE ORDER T: +44 (0)141 647 7100 23 sales@evolutionfasteners.co.uk www.evolutionfasteners.co.uk E: sales@evolutionfasteners.co.uk
S
SPECIFICATIONS AND LABORATORY SERVICES
SPECIFICATIONS AND LABORATORY SERVICES To support our various commercial and technical partners, as well as support specifiers and end users of our products, the Company provides testing services in our captive UKAS (United Kingdom Accreditation Service) accredited laboratory on system components or entire system mock-ups for the purposes of supporting the use of our products in conjunction with such a component or system by empirical
Where applicable, we will always perform such empirical testing pursuant to tests included on our schedule of accreditation.
Where empirical tests fall out with the scope of our schedule of accreditation, we will always apply the provisions of our accredited ISO/ IEC 17025 quality management system to ensure that the results of such testing are validated. Our schedule of accreditation can be viewed on the UKAS website, www.ukas.com.
This service is generally provided on a pro gratis basis, contingent ultimately on the specification and use of the Companies’ products for the application. The Company has significantly invested in creating a centre of excellence not only by purchasing research grade analytical equipment, but also in the creation of an exceptionally highly skilled multi-disciplinary team of civil, chemical, mechanical and structural engineers. The Company urges readers of this document to make use of our technical resources as they are generally provided on a pro gratis basis.
SPECIFICATIONS AND LABORATORY SERVICES
The testing and analytical services we offer include, but are not limited to:
Mechanical properties of fasteners and systems including tensile strength, compressive strength, material yield strength, shear strength, bending capacity, torque capacity, surface/ core hardness, depth of case hardening, etc -
Mechanical interaction properties of fastener assemblies including withdrawal resistance, pry-out resistance, pull-through resistance, torque behaviour, delamination strength, lap-shearing/ block-tearing resistance, etc, -
Corrosion resistance properties of fasteners and fastener assemblies including neutral salt spray resistance, cyclic corrosion resistance, wetting and humidity resistance, coating thickness measurement, etc,
Failure analysis techniques utilising light metallurgical microscopy or SEM (Scanning Electron Microscope) microscopy, high speed videography, metrology, etc, Chemical composition and PMI (Positive Material Identification)utilising our extensive spectrometrysuite of XRF (X-Ray Fluorescence), FTIR (Fourier Transform Infrared), UV-Vis (Ultraviolet-visible) and OES (Optical Emission Spectrometry) spectrometry techniques.
If you want to discuss how we can support you using our extensive laboratory and technical capabilities, contact the Evolution Technical Team for further assistance by e-mail to technical@evolutionfasteners.co.uk or by telephone call to +44 (0) 141 647 7100.
25
FIXING FINDER
PIR, PUR, XPS, EPS, PF AND PE INSULATION BOARDS
PIR
PIR boards are the most popular type of rigid insulation boards currently available.
BRANDS
PUR
Ballytherm®
Kingspan®
Celotex®
Quinn Therm®
EcoTherm®
Recticel®
Icopal®
U-Value Insulated Products®
IKO®
Warmline®
PUR insulation can be injected into wall cavities to create an energy efficient barrier. The foam is able to reach small spaces to create an air-tight seal. Dow®
BRANDS
XPS
XPS is a closed cell insulation product commonly used in remodeling and new construction applications.
BRANDS
26
Fibran®
Cellecta®
Jackson Insulation®
Danosa®
Kay-Metzeler®
Dow®
Kingspan®
Fibran®
Ravatherm®
Jablite®
Stylite®
PIR, PUR, XPS, EPS, PF AND PE INSULATION BOARDS
EPS
EPS insulation board is high-performing thermal insulation. It upgrades the thermal properties of a building, improving U-values, reducing the risk of water penetration and condensation.
BRANDS
PF
Jackson Insulation®
Danosa®
Kay-Metzeler®
Dow®
Kingspan®
Fibran®
Ravatherm®
Jablite®
Stylite®
Phenolic foam is considered one of the best material for thermal insulation.
BRANDS
PE
Cellecta®
Cellecta®
Jackson Insulation®
Danosa®
Kay-Metzeler®
Dow®
Kingspan®
Fibran®
Ravatherm®
Jablite®
Stylite®
PE exhibits stable thermal properties which save energy and offset pipe freezing over the entire life of a domestic heating system.
BRANDS
Cellecta®
Jackson Insulation®
Danosa®
Kay-Metzeler®
Dow®
Kingspan®
Fibran®
Ravatherm®
Jablite®
Stylite®
27
FIXING FINDER BOARDS BETWEEN
0mm to 50mm
For use in C1, C2 and C3 (internal) corrosivity category applications
Fixing Required by Substrate Type Insulation Thickness (mm)
Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Washer/ Stress Plate Detail
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
Non-Fire Rated
A1 Fire Rated
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
10
WHX32 PAGE16
TSTF4.8-38-3 PAGE17
TSTF5.5-42-5 PAGE17
WHX42 PAGE16
GIA801 PAGE8
MSHH6.3-45-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
20
WHX42 PAGE16
TSTF5.5-50-3 PAGE17
TSTF5.5-65-5 PAGE17
IS60 PAGE6
GIA801 PAGE8
MSHH6.3-57-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
25
WHX42 PAGE16
TSTF5.5-50-3 PAGE17
TSTF5.5-65-5 PAGE17
IS60 PAGE6
GIA801 PAGE8
MSHH6.3-57-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
30
WHX42 PAGE16
TSTF5.5-50-3 PAGE17
TSTF5.5-65-5 PAGE17
IS60 PAGE6
GIA801 PAGE8
MSHH6.3-57-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
35
IS60 PAGE6
TSTF5.5-62-3 PAGE17
TSTF5.5-85-5 PAGE17
IS60 PAGE6
GIA801 PAGE8
MSHH6.3-70-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
40
IS60 PAGE6
TSTF5.5-62-3 PAGE17
TSTF5.5-85-5 PAGE17
IS60 PAGE6
GIA801 PAGE8
MSHH6.3-70-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
45
IS80 PAGE6
TSTF5.5-80-3 PAGE17
TSTF5.5-85-5 PAGE17
IS80 PAGE6
GIA901 PAGE8
MSHH6.3-82-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
50
IS80 PAGE6
TSTF5.5-80-3 PAGE17
TSTF5.5-85-5 PAGE17
IS80 PAGE6
GIA901 PAGE8
MSHH6.3-82-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
BOARDS BETWEEN
50mm to 100mm
For use in C1, C2 and C3 (internal) corrosivity category applications
Fixing Required by Substrate Type Insulation Thickness (mm)
Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Washer/ Stress Plate Detail
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
Non-Fire Rated
A1 Fire Rated
IS100 PAGE6
GIA1101 PAGE8
MSHH6.3-100-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
TSTF5.5-110-5 PAGE17
IS100 PAGE6
GIA1101 PAGE8
MSHH6.3-100-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
TSTF5.5-100-3 PAGE17
TSTF5.5-110-5 PAGE17
IS100 PAGE6
GIA1101 PAGE8
MSHH6.3-100-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
IS100 PAGE6
TSTF5.5-100-3 PAGE17
TSTF5.5-110-5 PAGE17
IS120 PAGE6
GIA1101 PAGE8
MSHH6.3-100-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
80
IS100 PAGE6
TSTF5.5-120-3 PAGE17
TSTF5.5-110-5 PAGE17
IS120 PAGE6
GIA1401 PAGE8
MSHH6.3-125-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
85
IS100 PAGE6
TSTF5.5-120-3 PAGE17
TSTF5.5-110-5 PAGE17
IS120 PAGE6
GIA1401 PAGE8
MSHH6.3-125-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
90
IS100 PAGE6
TSTF5.5-120-3 PAGE17
TSTF5.5-135-5 PAGE17
IS120 PAGE6
GIA1401 PAGE8
MSHH6.3-125-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
95
IS120 PAGE6
TSTF5.5-120-3 PAGE17
TSTF5.5-135-5 PAGE17
IS140 PAGE6
GIA1401 PAGE8
MSHH6.3-140-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
100
IS120 PAGE6
TSTF5.5-120-3 PAGE17
TSTF5.5-135-5 PAGE17
IS140 PAGE6
GIA1401 PAGE8
MSHH6.3-140-516 PAGE14
ECW602 PAGE21
SPR703 PAGE20
28
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
60
IS80 PAGE6
TSTF5.5-80-3 PAGE17
TSTF5.5-100-5 PAGE17
65
IS80 PAGE6
TSTF5.5-100-3 PAGE17
70
IS80 PAGE6
75
PIR, PUR, XPS, EPS, PF AND PE INSULATION BOARDS BOARDS BETWEEN
100mm to 200mm
For use in C1, C2 and C3 (internal) corrosivity category applications
Fixing Required by Substrate Type Insulation Thickness (mm)
Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Washer/ Stress Plate Detail
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
Non-Fire Rated
A1 Fire Rated
IS140 PAGE6
GIA1701 PAGE8
MSHH6.3-140-516 PAGE14
ECW602 PAGE21
SPR704 PAGE20
TSTF5.5-150-5 PAGE17
IS160 PAGE6
GIA1701 PAGE8
MSHH6.3-160-516 PAGE14
ECW602 PAGE21
SPR704 PAGE20
TSTF5.5-180-3 PAGE17
TSTF5.5-180-5 PAGE17
IS180 PAGE6
GIA1701 PAGE8
MSHH6.3-160-516 PAGE14
ECW602 PAGE21
SPR704 PAGE20
IS160 PAGE6
TSTF5.5-180-3 PAGE17
TSTF5.5-180-5 PAGE17
IS180 PAGE6
GIA2001 PAGE8
MSHH6.3-180-516 PAGE14
ECW602 PAGE21
SPR704 PAGE20
150
IS160 PAGE6
TSTF5.5-180-3 PAGE17
TSTF5.5-180-5 PAGE17
IS180 PAGE6
GIA2001 PAGE8
MSHH6.3-180-516 PAGE14
ECW602 PAGE21
SPR704 PAGE20
160
IS180 PAGE6
TSTF5.5-180-3 PAGE17
None
IS200 PAGE6
GIA2001 PAGE8
MSHH6.3-200-516 PAGE14
ECW602 PAGE21
SPR704 PAGE20
180
IS200 PAGE6
None
None
IS220 PAGE6
GIA2401 PAGE8
None
ECW602 PAGE21
SPR704 PAGE20
190
IS200 PAGE6
None
None
IS220 PAGE6
GIA2401 PAGE8
None
ECW602 PAGE21
SPR704 PAGE20
200
IS220 PAGE6
None
None
IS220 PAGE6
GIA2401 PAGE8
None
ECW602 PAGE21
SPR704 PAGE20
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
110
IS120 PAGE6
TSTF5.5-150-3 PAGE17
TSTF5.5-150-5 PAGE17
120
IS140 PAGE6
TSTF5.5-150-3 PAGE17
130
IS140 PAGE6
140
NOTE: Telescopic tube washers are available for use in warm roof/ flat roof applications along with a smaller fastener please refer to RW product range (Page 21)
1Diameter can be increased to resist pull-over failure using GIW80 (Page 20), 2Diameter can be increased to resist pull-over failure using ECW90 (Page 21), 3Diameter can be increased to resist pull-over failure using SPR90 (Page 20).
4Diameter can be increased to resist pull-over failure using SSSPR90 (Page 20).
29
FIXING FINDER BOARDS BETWEEN
0mm to 50mm
For use in C3 and C4 (internal) corrosivity category applications
Fixing Required by Substrate Type Insulation Thickness (mm)
Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Washer/ Stress Plate Detail
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
Non-Fire Rated
A1 Fire Rated
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
10
BMDW4842 PAGE19
BMDW5.5-50-3 PAGE19
BMDW5.5-65-5 PAGE19
A4IS45 PAGE7
A2GIA801 PAGE8
A4HH6.3-45-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
20
BMDW4842 PAGE19
BMDW5.5-50-3 PAGE19
BMDW5.5-65-5 PAGE19
A4IS60 PAGE7
A2GIA801 PAGE8
A4HH6.3-57-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
25
BMDW4842 PAGE19
BMWD5.5-62-3 PAGE18
BMDW5.5-65-5 PAGE19
A4IS60 PAGE7
A2GIA801 PAGE8
A4HH6.3-57-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
30
BMDW4842 PAGE19
BMWD5.5-62-3 PAGE18
BMDW5.5-65-5 PAGE19
A4IS60 PAGE7
A2GIA801 PAGE8
A4HH6.3-57-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
35
A4IS60 PAGE7
BMWD5.5-62-3 PAGE18
BMWD5.5-85-5 PAGE18
A4IS60 PAGE7
A2GIA801 PAGE8
A4HH6.3-70-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
40
A4IS60 PAGE7
BMWD5.5-62-3 PAGE18
BMWD5.5-85-5 PAGE18
A4IS60 PAGE7
A2GIA801 PAGE8
A4HH6.3-70-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
45
A4IS80 PAGE7
BMWD5.5-80-3 PAGE18
BMWD5.5-85-5 PAGE18
A4IS80 PAGE7
A2GIA801 PAGE8
A4HH6.3-82-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
50
A4IS80 PAGE7
BMWD5.5-80-3 PAGE18
BMWD5.5-85-5 PAGE18
A4IS80 PAGE7
A2GIA901 PAGE8
A4HH6.3-82-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
BOARDS BETWEEN
50mm to 100mm
For use in C3 and C4 (internal) corrosivity category applications
Fixing Required by Substrate Type Insulation Thickness (mm)
Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
Non-Fire Rated
A1 Fire Rated
Washer/ Stress Plate Detail
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
60
A4IS80 PAGE7
BMWD5.5-80-3 PAGE18
BMWD5.5-110-5 PAGE18
A4IS100 PAGE7
A2GIA1101 PAGE8
A4HH6.3-100-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
65
A4IS80 PAGE7
BMWD5.5-100-3 PAGE18
BMWD5.5-110-5 PAGE18
A4IS100 PAGE7
A2GIA1101 PAGE8
A4HH6.3-100-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
70
A4IS80 PAGE7
BMWD5.5-100-3 PAGE18
BMWD5.5-110-5 PAGE18
A4IS100 PAGE7
A2GIA1101 PAGE8
A4HH6.3-100-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
75
A4IS100 PAGE7
BMWD5.5-100-3 PAGE18
BMWD5.5-110-5 PAGE18
A4IS120 PAGE7
A2GIA1101 PAGE8
A4HH6.3-100-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
80
A4IS100 PAGE7
BMWD5.5-120-3 PAGE18
BMWD5.5-110-5 PAGE18
A4IS120 PAGE7
A2GIA1401 A4HH6.3-125-516 PAGE8 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
85
A4IS100 PAGE7
BMWD5.5-120-3 PAGE18
BMWD5.5-135-5 PAGE18
A4IS120 PAGE7
A2GIA1401 A4HH6.3-125-516 PAGE8 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
90
A4IS100 PAGE7
BMWD5.5-120-3 PAGE18
BMWD5.5-135-5 PAGE18
A4IS120 PAGE7
A2GIA1401 A4HH6.3-125-516 PAGE8 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
95
A4IS120 PAGE7
BMWD5.5-120-3 PAGE18
BMWD5.5-135-5 PAGE18
A4IS140 PAGE7
A2GIA1401 A4HH6.3-140-516 PAGE8 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
100
A4IS120 PAGE7
BMWD5.5-120-3 PAGE18
BMWD5.5-135-5 PAGE18
A4IS140 PAGE7
A2GIA1401 A4HH6.3-140-516 PAGE8 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
30
PIR, PUR, XPS, EPS, PF AND PE INSULATION BOARDS BOARDS BETWEEN
100mm to 200mm
For use in C3 and C4 (internal) corrosivity category applications
Fixing Required by Substrate Type Insulation Thickness (mm)
Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Washer/ Stress Plate Detail
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
Non-Fire Rated
A1 Fire Rated
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
110
A4IS120 PAGE7
None
None
A4IS140 PAGE7
A2GIA1701 PAGE8
A4HH6.3-140-516 PAGE12
ECW602 PAGE21
SSSPR70 PAGE20
120
A4IS140 PAGE7
None
None
A4IS160 PAGE7
A2GIA1701 PAGE8
None
ECW602 PAGE21
SSSPR70 PAGE20
130
A4IS140 PAGE7
None
None
A4IS180 PAGE7
A2GIA1701 PAGE8
None
ECW602 PAGE21
SSSPR70 PAGE20
140
A4IS160 PAGE7
None
None
A4IS180 PAGE7
None
None
ECW602 PAGE21
SSSPR70 PAGE20
150
A4IS160 PAGE7
None
None
A4IS180 PAGE7
None
None
ECW602 PAGE21
SSSPR70 PAGE20
160
A4IS180 PAGE7
None
None
A4IS200 PAGE7
None
None
ECW602 PAGE21
SSSPR70 PAGE20
180
A4IS180 PAGE7
None
None
A4IS200 PAGE7
None
None
ECW602 PAGE21
SSSPR70 PAGE20
190
A4IS200 PAGE7
None
None
A4IS220 PAGE7
None
None
ECW602 PAGE21
SSSPR70 PAGE20
200
A4IS200 PAGE7
None
None
A4IS220 PAGE7
None
None
ECW602 PAGE21
SSSPR70 PAGE20
NOTE: Telescopic tube washers are available for use in warm roof/ flat roof applications along with a smaller fastener please refer to RW product range (Page 21)
1 Diameter can be increased to resist pull-over failure using A2PIW80 (Page 20), 2 Diameter can be increased to resist pull-over failure using ECW90 (Page 21).
31
FIXING FINDER
GLASS, ROCK, STONE AND MINERAL WOOL ROLLS, BATTENS, MATTRESSES AND BOARDS For use in C1, C2 and C3 (internal) corrosivity category applications
Fixing Required by Substrate Type Insulation Thickness (mm)
Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Washer/ Stress Plate Detail
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
IS80 PAGE6
GIA901 PAGE8
MSHH6.3-82-516 PAGE14
SPR702 PAGE20
TSTF5.5-100-5 PAGE17
IS100 PAGE6
GIA1101 PAGE8
MSHH6.3-100-516 PAGE14
SPR702 PAGE20
TSTF5.5-100-3 PAGE17
TSTF5.5-110-5 PAGE17
IS120 PAGE6
GIA1101 PAGE8
MSHH6.3-100-516 PAGE14
SPR702 PAGE20
IS120 PAGE6
TSTF5.5-120-3 PAGE17
TSTF5.5-135-5 PAGE17
IS140 PAGE6
GIA1401 PAGE8
MSHH6.3-140-516 PAGE14
SPR702 PAGE20
110
IS120 PAGE6
TSTF5.5-150-3 PAGE17
TSTF5.5-150-5 PAGE17
IS140 PAGE6
GIA1701 PAGE8
MSHH6.3-140-516 PAGE14
SPR702 PAGE20
125
IS140 PAGE6
TSTF5.5-180-3 PAGE17
TSTF5.5-180-5 PAGE17
IS180 PAGE6
GIA1701 PAGE8
MSHH6.3-160-516 PAGE14
SPR702 PAGE20
150
IS160 PAGE6
TSTF5.5-180-3 PAGE17
TSTF5.5-180-5 PAGE17
IS180 PAGE6
GIA2001 PAGE8
MSHH6.3-180-516 PAGE14
SPR702 PAGE20
180
IS200 PAGE6
None
None
IS220 PAGE6
GIA2401 PAGE8
None
SPR702 PAGE20
190
IS200 PAGE6
None
None
IS220 PAGE6
GIA2401 PAGE8
None
SPR702 PAGE20
200
IS220 PAGE6
None
None
IS240 PAGE6
GIA2401 PAGE8
None
SPR702 PAGE20
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
50
IS80 PAGE6
TSTF5.5-80-3 PAGE17
TSTF5.5-85-5 PAGE17
60
IS80 PAGE6
TSTF5.5-80-3 PAGE17
75
IS100 PAGE6
100
GLASS
Glass wool insulation, also known as fibreglass, is made from glass fibres. Glass is heated to very high temperatures until it melts, andis then spun quickly to create fibres.
ROCK
Rock wool has excellent sound-deadening properties and higher insulating value than fiberglass.
32
GLASS, ROCK, STONE AND MINERAL WOOL ROLLS For use in C3 and C4 (internal) corrosivity category applications
Fixing Required by Substrate Type Cold or Hot Rolled Mild Structural Steel (S235 to S480)
Insulation Thickness (mm)
Kiln Dry Structural Timber (≥ C16)
Blockwork, Masonry and Concrete
Washer/ Stress Plate Detail
Masonry (≥ 7N)
Concrete (≥ C25 ≤ C50)
A4IS80 PAGE7
A2GIA903 PAGE8
A4HH6.3-82-516 PAGE12
SSSPR70 PAGE20
BMWD5.5-110-5 PAGE18
A4IS100 PAGE7
A2GIA1103 PAGE8
A4HH6.3-100-516 PAGE12
SSSPR70 PAGE20
BMWD5.5-100-3 PAGE18
BMWD5.5-110-5 PAGE18
A4IS120 PAGE7
A2GIA1103 PAGE8
A4HH6.3-100-516 PAGE12
SSSPR70 PAGE20
A4IS120 PAGE7
BMWD5.5-120-3 PAGE18
BMWD5.5-135-5 PAGE18
A4IS140 PAGE7
A2GIA1403 PAGE8
A4HH6.3-140-516 PAGE12
SSSPR70 PAGE20
110
A4IS120 PAGE7
None
None
A4IS140 PAGE7
A2GIA1703 PAGE8
A4HH6.3-140-516 PAGE12
SSSPR70 PAGE20
125
A4IS140 PAGE7
None
None
A4IS180 PAGE7
A2GIA1703 PAGE8
None
SSSPR70 PAGE20
150
A4IS160 PAGE7
None
None
A4IS180 PAGE7
None
None
SSSPR70 PAGE20
180
A4IS180 PAGE7
None
None
A4IS200 PAGE7
None
None
SSSPR70 PAGE20
190
A4IS200 PAGE7
None
None
A4IS220 PAGE7
None
None
SSSPR70 PAGE20
200
A4IS200 PAGE7
None
None
A4IS220 PAGE7
None
None
SSSPR70 PAGE20
≥ 0.5 ≤ 2.5mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
50
A4IS80 PAGE7
BMWD5.5-80-3 PAGE18
BMWD5.5-85-5 PAGE18
60
A4IS80 PAGE7
BMWD5.5-80-3 PAGE18
75
A4IS100 PAGE7
100
1 Diameter can be increased to resist pull-over failure using GIW80 (Page 20),
2 Diameter can be increased to resist pull-over failure using SPR90 (Page 20).
3 Diameter can be increased to resist pull-over failure using A2PIW80 (Page 20).
NOTE: Telescopic tube washers are available for use in warm roof/ flat roof applications along with a smaller fastener please refer to RW product range (Page 21)
MINERAL
STONE
Mineral Wool insulation products are designed and produced to ensure healthy, safe and environmentally-friendly places to live and work.
Stone wool delivers unique benefits as an insulation solution and effectively reduces airflow and sound transmission, while providing higher airflow resistivity for improved sound attenuation.
33
FIXING FINDER
FIXING STRUCTURAL, TRAPEZOIDAL, INSULATION PANELS WITH STEEL OR ALUMINIUM FASCIA’S FOR WALLS, ROOFING AND CLADDING IN THIS SECTION, THE 3 MOST POPULAR BRANDS FOR TRAPEZOIDAL INSULATION ARE SPLIT INTO TWO SECTIONS:
EVOSHIELD® C1, C2 AND C3 CORROSIVITY ENVIRONMENTS AND A2 STEEL STAINLESS FOR C3 AND C4 CORROSIVITY ENVIRONMENTS
34
TRAPEZOIDAL PANELS IN C1,C2 AND C3
KINGSPAN® INSULATED PANELS
C1, C2
C3
EvoShield® For use in and (internal) corrosivity category applications
Composite Panel Fasteners for Kingspan KS1000RW & KS2000RW Type Panels
CORE (TROUGH) FIXINGS Insulation CORE Thickness (mm)
40 53 60 73 80 91 100 115 120 137 150
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
TSBWHT5.5-80-3 PAGE10 TSBWHT5.5-80-3 PAGE10 TSBWHT5.5-105-3 PAGE10 TSBWHT5.5-105-3 PAGE10 TSBWHT5.5-105-3 PAGE10 TSBWHT5.5-135-3 PAGE10 TSBWHT5.5-135-3 PAGE10 TSBWHT5.5-150-3 PAGE10 TSBWHT5.5-150-3 PAGE10 TSBWHT5.5-185-3 PAGE10 TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-85-5 PAGE10 TSBWHT5.5-105-5 PAGE10 TSBWHT5.5-105-5 PAGE10 TSBWHT5.5-125-5 PAGE10 TSBWHT5.5-125-5 PAGE10 TSBWHT5.5-150-5 PAGE10 TSBWHT5.5-150-5 PAGE10 TSBWHT5.5-185-5 PAGE10 TSBWHT5.5-185-5 PAGE10 TSBWHT5.5-185-5 PAGE10 TSBWHT+5.5-235-5 PAGE10
TSBWHT6.3-80-GP PAGE10 TSBWHT6.3-100-GP PAGE10 TSBWHT6.3-100-GP PAGE10 TSBWHT6.3-120-GP PAGE10 TSBWHT6.3-120-GP PAGE10 TSBWHT6.3-150-GP PAGE10 TSBWHT6.3-150-GP PAGE10 TSBWHT6.3-150-GP PAGE10 None None None
35
FIXING FINDER CROWN (PEAK) FIXINGS Insulation CROWN Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
71
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
84
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
91
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
104
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
111
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
TSBWHT6.3-150-GP PAGE10
122
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
131
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
146
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
151
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
168
TSBWHT5.5-225-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
181
TSBWHT5.5-225-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
Composite Panel Fasteners for Kingspan® KS1000TS® Type Panels
CORE (TROUGH) FIXINGS Insulation CORE Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
40
TSBWHT5.5-80-3 PAGE10
TSBWHT5.5-85-5 PAGE10
TSBWHT6.3-80-GP PAGE10
50
TSBWHT5.5-80-3 PAGE10
TSBWHT5.5-105-5 PAGE10
TSBWHT6.3-100-GP PAGE10
60
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-105-5 PAGE10
TSBWHT6.3-100-GP PAGE10
70
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
80
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
100
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
115
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
TSBWHT6.3-150-GP PAGE10
120
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
137
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
150
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
36
TRAPEZOIDAL PANELS IN C1,C2 AND C3 CROWN (PEAK) FIXINGS Insulation CROWN Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
71
TSBWHT5.5-105-3
TSBWHT5.5-125-5
TSBWHT6.3-120-GP
81
TSBWHT5.5-135-3
TSBWHT5.5-125-5
TSBWHT6.3-120-GP
91
TSBWHT5.5-135-3
TSBWHT5.5-150-5
TSBWHT6.3-150-GP
101
TSBWHT5.5-135-3
TSBWHT5.5-150-5
TSBWHT6.3-150-GP
111
TSBWHT5.5-150-3
TSBWHT5.5-185-5
TSBWHT6.3-150-GP
131
TSBWHT5.5-185-3
TSBWHT5.5-185-5
None
146
TSBWHT5.5-185-3
TSBWHT5.5-185-5
None
151
TSBWHT5.5-185-3
TSBWHT5.5-235-5
None
168
TSBWHT5.5-225-3
TSBWHT5.5-235-5
None
181
TSBWHT5.5-225-3
TSBWHT5.5-235-5
None
PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10
PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10 PAGE10
PAGE10 PAGE10 PAGE10 PAGE10 PAGE10
Composite Panel Fasteners for Kingspan® KS1000AWP® Type Panels
TONGUE FIXINGS Insulation CORE Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
45
TSBWHT5.5-80-3 PAGE10
TSBWHT5.5-85-5 PAGE10
TSBWHT6.3-80-GP PAGE10
50
TSBWHT5.5-80-3 PAGE10
TSBWHT5.5-105-5 PAGE10
TSBWHT6.3-100-GP PAGE10
60
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-105-5 PAGE10
TSBWHT6.3-100-GP PAGE10
70
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
80
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
100
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
120
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
140
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
150
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
37
FIXING FINDER
EUROBOND INSULATED PANELS Composite Panel Fasteners for Eurobond® Europanel® Type Panels
Insulation CORE Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Timber Substrate
Steel Substrates ≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
75
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
100
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
125
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
150
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
175
TSBWHT5.5-225-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
200
TSBWHT5.5-225-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
240
TSBWHT5.5-275-3 PAGE10
None
None
Composite Panel Fasteners for Eurobond® Rockspan® & Rainspan® Type Panels
Insulation CORE Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
75
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
100
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
125
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
150
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
175
TSBWHT5.5-225-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
200
TSBWHT5.5-225-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
240
TSBWHT5.5-275-3 PAGE10
None
None
38
TRAPEZOIDAL PANELS IN C1,C2 AND C3
TATA INSULATED PANELS Composite Panel Fasteners for TATA® Trisomet® Type Panels
CORE (TROUGH) FIXINGS Insulation CORE Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
40
TSBWHT5.5-80-3 PAGE10
TSBWHT5.5-85-5 PAGE10
TSBWHT6.3-80-GP PAGE10
60
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-105-5 PAGE10
TSBWHT6.3-100-GP PAGE10
80
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
100
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
120
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
135
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
CROWN (PEAK) FIXINGS Insulation CROWN Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
72
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
92
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
112
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
TSBWHT6.3-150-GP PAGE10
132
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None
152
TSBWHT5.5-185-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
167
TSBWHT5.5-225-3 PAGE10
TSBWHT5.5-235-5 PAGE10
None
Composite Panel Fasteners for TATA® Trimapanel® Type Panels Insulation Thickness (mm)
EvoShield® for C1, C2 and C3 (internal) Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
70
TSBWHT5.5-105-3 PAGE10
TSBWHT5.5-125-5 PAGE10
TSBWHT6.3-120-GP PAGE10
90
TSBWHT5.5-135-3 PAGE10
TSBWHT5.5-150-5 PAGE10
TSBWHT6.3-150-GP PAGE10
120
TSBWHT5.5-150-3 PAGE10
TSBWHT5.5-185-5 PAGE10
None 39
FIXING FINDER
For use in
C3 and C4 (internal) corrosivity category applications
KINGSPAN® INSULATED PANELS
Composite Panel Fasteners for Kingspan KS1000RW & KS2000RW Type Panels
CORE (TROUGH) FIXINGS Insulation CORE Thickness (mm)
40
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
40
BMTSBWHT5.5-80-3 PAGE11
BMTSBWHT5.5-85-5 PAGE11
None
53
BMTSBWHT5.5-80-3 PAGE11
BMTSBWHT5.5-105-5 PAGE11
None
60
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-105-5 PAGE11
None
73
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
80
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
91
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
100
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
115
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
120
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
137
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
150
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
TRAPEZOIDAL PANELS IN C3 AND C4 CROWN (PEAK) FIXINGS Insulation CROWN Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates
Timber Substrate
≥ 4.0 ≤ 12.0 mm
≥ 1.2 ≤ 4.0 mm
71
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
81
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
91
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
104
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
111
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
122
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
131
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
146
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
151
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-235-5 PAGE11
None
168
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-235-5 PAGE11
None
181
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-235-5 PAGE11
None
≥ 4.0 ≤ 12.0 mm
Composite Panel Fasteners for Kingspan® KS1000TS® Type Panels
CORE (TROUGH) FIXINGS Insulation CORE Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
BMTSBWHT5.5-80-3 PAGE11
BMTSBWHT5.5-85-5 PAGE11
None
50
BMTSBWHT5.5-80-3 PAGE11
BMTSBWHT5.5-105-5 PAGE11
None
60
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-105-5 PAGE11
None
70
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
80
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
100
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
115
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
120
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
137
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
150
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
40
41
FIXING FINDER CROWN (PEAK) FIXINGS Insulation CROWN Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates
Timber Substrate
≥ 4.0 ≤ 12.0 mm
≥ 1.2 ≤ 4.0 mm
71
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
81
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
91
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
101
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
111
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
131
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
146
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
151
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
168
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
181
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
≥ 4.0 ≤ 12.0 mm
Composite Panel Fasteners for Kingspan® KS1000AWP® Type Panels
TONGUE FIXINGS Insulation CORE Thickness (mm)
42
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
45
BMTSBWHT5.5-80-3 PAGE11
BMTSBWHT5.5-85-5 PAGE11
None
50
BMTSBWHT5.5-80-3 PAGE11
BMTSBWHT5.5-105-5 PAGE11
None
60
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-105-5 PAGE11
None
70
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
80
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
100
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
120
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
140
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
150
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
TRAPEZOIDAL PANELS IN C3 AND C4
EUROBOND INSULATED PANELS
Composite Panel Fasteners for Eurobond® Europanel® Type Panels
Insulation CORE Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environmentss Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
100
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
125
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
150
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
175
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
200
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
240
BMTSBWHT5.5-275-3 PAGE11
None
None
75
Composite Panel Fasteners for Eurobond® Rockspan® & Rainspan® Type Panels
Insulation CORE Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environmentss Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
1BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
100
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
125
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
150
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
175
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
200
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-245-5 PAGE11
None
240
BMTSBWHT5.5-275-3 PAGE11
None
None
75
43
FIXING FINDER
TATA INSULATED PANELS Composite Panel Fasteners for TATA® Trisomet® Type Panels
CORE (TROUGH) FIXINGS Insulation CORE Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates
Timber Substrate
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0mm
(≥ C16)
BMTSBWHT5.5-80-3 PAGE11
BMTSBWHT5.5-85-5 PAGE11
None
60
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-105-5 PAGE11
None
80
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
100
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
120
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
135
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
40
CROWN (PEAK) FIXINGS Insulation CROWN Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates
Timber Substrate
≥ 4.0 ≤ 12.0mm
≥ 1.2 ≤ 4.0mm
≥ 4.0 ≤ 12.0 mm
72
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
92
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
112
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
132
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
152
BMTSBWHT5.5-185-3 PAGE11
BMTSBWHT5.5-235-5 PAGE11
None
167
BMTSBWHT5.5-235-3 PAGE11
BMTSBWHT5.5-235-5 PAGE11
None
Composite Panel Fasteners for TATA® Trimapanel® Type Panels
Insulation Thickness (mm)
A2 Stainless for C3 and C4 Corrosivity Environments Steel Substrates ≥ 1.2 ≤ 4.0mm
(≥ C16)
BMTSBWHT5.5-105-3 PAGE11
BMTSBWHT5.5-125-5 PAGE11
None
90
BMTSBWHT5.5-135-3 PAGE11
BMTSBWHT5.5-150-5 PAGE11
None
120
BMTSBWHT5.5-150-3 PAGE11
BMTSBWHT5.5-185-5 PAGE11
None
70
44
≥ 4.0 ≤ 12.0mm
Timber Substrate
Visit our website www.evolutionfasteners.co.uk for latest product information offers and Evolution news Sales and Customer Service sales@evolutionfasteners.co.uk Tel: +44 (0) 141 647 7100 Fax: +44 (0) 141 647 5100
INDEX Products CODE
PAGE
IS
Fixing insulation to steel and timber
6
A4IS
Fixing insulation to light gauge steel or timber substrates.
7
GIA/ A2GIA
Fixing rigid insulation boards and mineral wool insulation to blockwork, brickwork or concrete substrates
8
Fixing insulation and single ply membrane to plywood, timbers, steel decking and concrete.
9
TSBWHT
Fixing cladding and roofing applications to hot and cold rolled purlins/ rails
10
BMTSBWHT
Use in brick-tie channel systems and for fastening aluminium sheeting and panels
11
A4HH
Fixing timber battens, trunking, track and general components into concrete, masonry and timber
MSHH/MSCSK
Fixing timber battens, trunking, track and general components to concrete andmasonry substrates
14-15
Fixing cementitious and other dense boards to timber and metal substrates
16
TSTF
Fixing timber or composites to steel
17
BMWD
Fastening when stainless steel product is required
18
BMDW
Fixing cementitious and other dense boards to timber and metal substrates
19
Spreading the loading when fixing membrane, insulation and single ply materials in roofing...
20
For securing insulation to timber and sheet steel when used with Evolution drywall, IS etc
21
ERS
WHX/WHL
SPR/SSSPR
RW//EVNW/ EVPPW/ECW
EVPF 46
Quick through-fix for insulation boards into masonry/ aerated concrete/ brick/ concrete/ stone
12-13
22
Technical INSULATION
PAGE
PIR, PUR, XPS, EPS, PF AND PE INSULATION BOARDS
26-31
GLASS, ROCK, STONE AND MINERAL WOOL ROLLS, BATTENS, MATTRESSES AND BOARDS
32-33
FIXING STRUCTURAL, TRAPEZOIDAL, INSULATION PANELS WITH STEEL OR ALUMINIUM FASCIA’S FOR WALLS, ROOFING AND CLADDING
34-44
47
This document is wholly authored and published by Evolution Fasteners UK Ltd (herein referred to as “the company” or “Evolution") This document is intended to be a training tool and educational in nature only. The contents of this document do not constitute any form of warranty or guarantee. The Company provides an industry leading warranty which is detailed in a separate document. The use of this document does not alleviate, mitigate or otherwise change the legal obligations, or, statutory and regulatory burdens or undertakings of the reader apropos any law, statute, act, regulation, directive, standard, inter alia. This includes, but is not limited to the requirements under the Building Regulations and/ or the Construction (Design and Management) Regulations, amongst others. The Company recommends that on every occasion, the reader of this document undertakes their own research and determination as to whether a product or products are suitable for their specific application. Readers of this document are implored to seek the advice of the third parties mentioned in this document on their components and inter-compatibility with other parties’ components. Where references or citations are made, it is in the ‘Harvard Style’ pursuant to the guidance laid out by Imperial College London (Imperial College London, 2017).
ACKNOWLEDGEMENTS, LICENSES, TRADEMARKS AND COPYRIGHT Unless otherwise noted or referenced: all information, text, illustrations and content herein remain the intellectual property of the Company. Throughout this document, various third-party logos, brand names and trademarks are used under the fair dealings’ provisions of the Copyright, Designs and Patents Act 1988, herein referred to as “the 1988 Act”, specifically pursuant to Sections 29, 29A and 30 of the 1988 Act. The use of such logos, brand names or trademarks is not intended to convey any commercial relationship, or otherwise, between the Company and the third party concerned. The use of such logos, brand names or trademarks is solely intended to benefit and aid the reader in the initial visual recognition of such third party. This document is strictly published and provided without prejudice, without recourse, non-assumptist, errors and omissions excepted, no assured value, no liability and all rights reserved. The use of the UKAS logo and ILAC logo relates only to accredited tests pursuant to our schedule of accreditation, tests out with our schedule are marked “NC”. For the most current version of our schedule please visit www.ukas.com.
TERMS AND CONDITIONS OF SALE GENERAL
DEFECTIVE GOODS
TITLE AND RISK
1. (a) All orders placed with Evolution Fasteners UK Limited (”the Company”) by the Company’s customer (“the Buyer”) for the sale and the purchase of goods (“the Goods”)are subject to the terms and conditions set out below which shall constitute the contract between the Company and the Buyer (“the Contract”). No modifications or variations to these terms and conditions and no other terms and conditions shall be valid or effective unless expressly accepted in writing by a director of the Company. (b) Any subsequent orders placed with the Company shall be deemed to be placed subject to these terms and conditions unless expressly agreed otherwise in writing by a Director of the Company.
14. The Company shall at their option repair or replace any goods which are defective as to materials or workmanship provided that:
20.1The risk in the Goods shall pass to the Buyer on completion of delivery.
QUOTATIONS 2. A quotation by the Company does not constitute an offer and the Company reserves the right to withdraw or amend the same at any time prior to the Company’s acceptance of the Buyer’s order. The Buyers purchase order is binding and the Buyer is responsible for
PRICE 3. The price of any goods shall be the Company's list price of the goods prevailing at the date of acceptance of the order by the Company (less any agreed discount). 4. Unless otherwise stated all prices are exclusive of V.A.T. 5. The Company shall be entitled from time to time to vary list price or list prices without prior notice.
PAYMENT 6. Unless otherwise specified in writing by the Company, payment is due on or before the end of the month following that in which the goods were invoiced. 7. Failure by the Buyer to pay for any goods on the due date shall entitle the Company: (a) to cancel the balance (if any) of the contract under which the Buyer has failed to pay for the goods and to recover from the Buyer damages for any loss suffered by the Company as a result of such cancellation, and/or (b) to cancel any other contract or the balance of any other contract which the Company may have with the Buyer and to recover from the Buyer damages for any loss suffered by the Company as a result of such cancellation, and/or (c) to charge the Buyer interest at the rate of 2.5% per month calculated on a day-today basis on the amount due from the date of invoice to the date of actual payment thereof (both before and after any judgement) such interest to be paid on demand.
ACCOUNTS 8. The Company reserves the right to close a credit account at any time without prior notice whereupon the whole of the amount outstanding on such account shall become immediately due and payable in full.
COLLECTION AND DELIVERY 9. Where the Company agrees to deliver any goods to the Buyer: (a) The Buyer shall pay the Company's delivery charges therefore at the rate or rates prevailing at the date of acceptance of the order by the Company or at such other rate or rates as may be agreed between the Company and the Buyer prior to the date of acceptance of the order by the Company. (b) Delivery of the goods shall be made to such place or places as agreed between the Company and the Buyer. (c) The Buyer will ensure that there is adequate access to the place of delivery and that there is made available at the place of delivery adequate labour and other facilities in order to enable the goods to be unloaded promptly and safely and the Buyer will indemnify the Company in respect of any losses costs and expenses incurred by the Company as a consequence thereof and (without prejudice to the generality of the foregoing) the Company shall be entitled to charge the Buyer for the storage of the goods whether at the Company's premises or otherwise. (d) If the Buyer shall refuse for any reason whatsoever to accept delivery of the goods the Buyer will indemnify the Company in respect of all losses costs and expenses incurred by the Company as a consequence thereof and (without prejudice to the generality of the foregoing) the Company shall be entitled to charge the Buyer for the storage of the goods whether at the Company's premises or otherwise. (e) The Company shall be entitled to make part deliveries of the goods and for the purposes of these terms and conditions each such part delivery shall be treated as a separate and independent contract for the sale of goods to the Buyer. 10. (a) Any times stated for collection or delivery shall be a bona fide estimate only and whilst the Company will use all reasonable endeavours to meet any such times stated the Company shall not be liable for any delay howsoever caused. (b) Where no times are stated for collection or delivery the Company will use all reasonable endeavours to make the goods available for collection or to deliver the goods (as the case may be) as soon as reasonably practicable. (c) The Company shall be entitled to stop collection by or to withhold delivery to the Buyer of any goods where at the time collection or delivery payment is due to the Company in respect of any goods supplied to the Buyer under any contract whatsoever.
DAMAGE OR LOSS IN TRANSIT 11. Where the Company is responsible for delivering the goods to the Buyer the Company will at its option repair or replace free of charge any goods lost or damaged in transit provided that: (a) (save in respect of a total loss or non-delivery of the goods) details of any loss or damage have been marked on the copy of the consignment note or delivery documents signed by the Buyer and advised to the Company within 48 hours of delivery and confirmed in writing to the Company with full particulars within 3 days of delivery, and (b) in respect of a total loss or non- delivery of the goods details are advised to the Company in writing (otherwise than on a consignment note or delivery document) with full particulars within (7 days) of the date of the Company's invoice in respect of the goods.
SHORT DELIVERY 12. The Company shall not be responsible for any short delivery unless details thereof are marked on the consignment note or delivery document signed by the Buyer and in the case of loss in transit all the requirements set out in Condition 11(b) above are fulfilled.
STORAGE 13. Where the Company has notified the Buyer that the goods are ready for delivery, the Buyer shall take delivery or arrange for storage. If the Buyer does not so take delivery or arrange for storage within 7 days of notification the Company shall be entitled to invoice and be paid for the goods as though the goods had been duly delivered in accordance with these instructions and the Company may arrange storage either at the Company’s own premises or elsewhere on the Buyer’s behalf and all charges for storage, insurance and demurrage shall be payable by the Buyer.
(a) where any alleged defect is discoverable on an inspection of the goods (whether or not the Buyer shall actually inspect the goods) notification of the alleged defect with full particulars thereof is received by the Company in writing within 7 days of the date of collection or delivery of the goods and in any other case notification of the alleged defect is received by the Company in writing with full particulars thereof within 10 days of the date of collection or delivery of the goods, and (b) the Company is notified in writing with full particulars immediately upon discovery of the alleged defect and is afforded the opportunity of inspecting the goods at the premises of the Buyer or if so required by the Company the Buyer immediately returns the goods to the Company's premises carriage paid (but refundable insofar as the goods are repaired or replaced), and (c) any defect is not due to wear and tear neglect abnormal use misuse or improper adjustment. (d) The Company shall not be liable for transportation or installation charges, for expense of the Buyers for repairs or replacements or for damages for delay or loss of use or other indirect, incidental or consequential damage of any kind. 15. (a) As against a person dealing as a consumer as defined by Section 2(3) of the Consumer Rights Act 2015 the following provisions apply. The Company is under a legal duty to supply products that are in conformity with its obligations. The box below contains a summary of the Buyer’s key legal rights in relation to the Goods. Nothing in these terms will affect the Buyer’s legal rights.
Summary of the Buyer’s key legal rights This is a summary of the Buyer’s key legal rights. These are subject to certain exceptions. For detailed information please visit the Citizens Advice website www. adviceguide.org.uk or call 03454 04 05 06 . The Consumer Rights Act 2015 says the Goods must be as described, fit for purpose and of satisfactory quality. During the expected lifespan of the Goods the Buyer’s legal rights entitle the Buyer to the following: a)Up to 30 days: if the Goods are faulty, then the Buyer can obtain an immediate refund. b) Up to 6 months: if the Goods cannot be repaired or replaced, then the Buyer is entitled to a full refund, in most cases. c) Up to 6 years: if the Goods do not last a reasonable length of time the Buyer may be entitled to some money back.
20.2 Title to the Goods shall not pass to the Buyer until the earlier of: (a) the Company receiving payment in full (in cash or cleared funds) for the Goods and any other goods that the Company has supplied to the Buyer, in which case title to the Goods shall pass at the time of payment of all such sums; and (b) the Buyer reselling the Goods, in which case title to the Goods shall pass to the Buyer at the time specified in clause 20.4. 20.3 Until title to the Goods has passed to the Buyer, the Buyer shall: (a) store the Goods separately from all other goods held by the Buyer so that they remain readily identifiable as the Company's property; (b) not remove, deface or obscure any identifying mark or packaging on or relating to the Goods; (c) maintain the Goods in satisfactory condition and keep them insured against all risks for their full price from the date of delivery; (d) notify the Company immediately if it becomes subject to any of the events listed in clause 21; and (e) give the Company such information relating to the Goods as the Company may require from time to time. 20.4 Subject to clause 20.5, the Buyer may resell or use the Goods in the ordinary course of its business (but not otherwise) before the Company receives payment for the Goods. However, if the Buyer resells the Goods before that time: (a) it does so as principal and not as the Company’s agent; and (b) title to the Goods shall pass from the Company to the Buyer immediately before the time at which resale by the Buyer occurs. 20.5 If before title to the Goods passes to the Customer the Customer becomes subject to any of the events listed in clause 21, then, without limiting any other right or remedy the Company may have: (a) the Buyer's right to resell the Goods or use them in the ordinary course of its business ceases immediately; and (b) the Company may at any time: (i) require the Buyer to deliver up all Goods in its possession that have not been resold, or irrevocably incorporated into another product; and (ii) if the Buyer fails to do so promptly, enter any premises of the Buyer or of any third party where the Goods are stored in order to recover them. 20.6 Each and every sub-clause of this clause shall be deemed to be separate from the remainder of the contract and severable accordingly.
See also Exercising your right to change your mind (Consumer Contracts Regulations 2013).
TERMINATION
If the Buyer wishes to exercise its legal rights to reject the Goods the Buyer must either return them in person, or post them back, to the Company. The Company will pay the costs of postage or collection. Please telephone the Company for a return label or to arrange collection. The provisions contained in this condition 15(a) do not affect the Buyer’s legal rights in relation to faulty or mis-described products
21.1 Without limiting its other rights or remedies, the Company may terminate this Contract with immediate effect by giving written notice to the Buyer if: (a) the Buyer commits a material breach of any term of the Contract and (if such a breach is remediable) fails to remedy that breach within 7 days of that party being notified in writing to do so; (b) the Buyer takes any step or action in connection with its entering administration, provisional liquidation or any composition or arrangement with its creditors (other than in relation to a solvent restructuring), being wound up (whether voluntarily or by order of the court, unless for the purpose of a solvent restructuring), having a receiver appointed to any of its assets or ceasing to carry on business or, if the step or action is taken in another jurisdiction, in connection with any analogous procedure in the relevant jurisdiction; (c) the Buyer suspends, threatens to suspend, ceases or threatens to cease to carry on all or a substantial part of its business; or (d) the Buyer's financial position deteriorates to such an extent that in the Company's opinion the Buyer's capability to adequately fulfil its obligations under the Contract has been placed in jeopardy.
(b)As against a person dealing otherwise than as a consumer as defined by Section 2(3) of the Consumer Rights Act 2015 the provisions contained in Condition 14 above shall be accepted in substitution for and to the entire exclusion of all conditions and warranties and liabilities whatsoever whether express or implied by statute (save those implied by virtue of Section 12 of the Sale of Goods Act 1979) common law usage or otherwise. 16. Save and except as expressly stated in Conditions 14 and 15 above the Company shall not be liable for any defect in the Goods or for any injury or loss resulting from the Goods or any defect therein or from any work done in connection therewith whether such liability is due to the negligence of any servant employee or agent of the Company or otherwise. 17. As against a person dealing otherwise than as a consumer as defined by Section 2(3) of the Consumer Rights Act 2015 in the event that the Company shall be liable to repair or replace the Goods, in no circumstances shall the Company’s liability extend beyond the cost of repair or replacing the Goods. In any event, notwithstanding anything contained in the contract, as against such person in no circumstances shall the Company be liable in contract, tort (including negligence or breach of statutory duty) or otherwise howsoever and whatsoever the cause thereof: i.For any increased costs or expenses ii. For any loss or profit, business contracts, revenues or anticipated savings or iii. For any special direct or consequential damage of any nature whatsoever said to have occurred consequent on the supply or the circumstances of the supply of the Goods.
RETURNED GOODS 18. (a) Where returned Goods are found to be damaged due to the Buyer's fault the Buyer will be liable for the cost of remedying such damage (b) The Company will not accept Goods for credit or rectification unless such return has been pre-authorised by the Company, and the Goods are received by the Company in stock condition, with original packaging and the Company retains the right at its sole discretion whether to accept the return of the Goods or whether to rectify the Goods or whether to issue a credit note in respect thereof. (c) The Buyer shall unless otherwise stated be responsible for the cost of outward and return carriage and insurance of all Goods returned by the Buyer to the Company for rectification or credit which Goods shall be at the risk of the Buyer until actual receipt of the Goods by the Company. The onus of proof of safe delivery shall rest with the Buyer. (d) All Goods returned to the Company by prearrangement and found to contain no fault, will be subject to a 30% restocking charge, providing the Goods are in original stock condition. Any downward variation of this restocking charge shall be at the sole discretion of the Company. (e) No credit shall be allowed for Goods until they have been received complete.
FORCE MAJEURE 19. (a) The Company shall not be responsible for any loss damage delay or nonperformance of any contract arising whether directly or indirectly from any cause outside the control of the Company including (but without prejudice to the generality of the foregoing) any cause arising from or attributable to strike lock-out shortage of labour or materials governmental action civil commotion riots wars sabotage storm flood earthquake drought machinery breakdown failure of plant collapse of structures voluntary or mandatory compliance with any direction request or order of any person having or appearing to have authority whether for defence or other governmental or national purposes inability to obtain raw materials equipment fuel power components or transportation. (b) In the event of any delay or non- performance of any contract arising whether directly or indirectly from any cause referred to in Condition 19(a) above the Company shall be entitled to cancel any contract without payment to the Buyer in respect of any loss or damage or otherwise.
21.2 Without limiting its other rights or remedies, the Company may suspend provision of the Goods under the Contract or any other contract between the Buyer and the Company if the Buyer becomes subject to any of the events listed in clause 21.1(a) to clause 21.1(d), or the Company reasonably believes that the Buyer is about to become subject to any of them, or if the Buyer fails to pay any amount due under this Contract on the due date for payment. 21.3 Without limiting its other rights or remedies, the Company may terminate the Contract with immediate effect by giving written notice to the Buyer if the Buyer fails to pay any amount due under the Contract on the due date for payment. 21.4 On termination of the Contract for any reason the Buyer shall immediately pay to the Company all of the Company's outstanding unpaid invoices and interest. 21.5 Termination of the Contract shall not affect any of the parties' rights and remedies that have accrued as at termination, including the right to claim damages in respect of any breach of this Contract that existed at or before the date of termination. 21.6 Any provision of the Contract that expressly or by implication is intended to come into or continue in force on or after termination shall remain in full force and effect.
GOVERNING LAW AND JURISDICTION 22. The Contract and all contracts between the Company and the Buyer shall in respects be governed by English law and all disputes which may arise out of or in connection with these Conditions or the Contract or any contract between the Company and the Buyer or any Goods supplied or to be supplied under the Contract or any contract shall be subject to the exclusive jurisdiction of the English Courts save that the Company shall be at liberty to bring any legal proceedings against the Buyer in the Courts of any other country which it considers appropriate. 23. In the event that the Company shall bring any legal proceedings against the Buyer in connection with these Conditions or the Contract or any contract between the Company and the Buyer or any Goods supplied or to be supplied under the Contract or any contract between the Company and the Buyer the Buyer shall indemnify the Company against all costs and expenses incurred by the Company in connection therewith on a full indemnity basis.
THIRD PARTIES 24. For the avoidance of doubt nothing in these terms and conditions are intended to confer on any third party any benefit or the right to enforce any terms within the conditions.
Visit our website www.evolutionfasteners.co.uk for latest product information offers and Evolution news Administration and Accounts Tel: +44 (0) 20 8905 2759 Fax: +44 (0) 20 8207 0044 Sales and Customer Service Tel: +44 (0) 141 647 7100 Fax: +44 (0) 141 647 5100 Email: sales@evolutionfasteners.co.uk
WW W. EV OL UT IO NF AS TE NE RS .CO .U K
Copyright 2020 Evolution Fasteners (UK) Ltd. All rights reserved.