energystore TLA® Case Study - Millbury Nursing Home

Page 1


Millbury Nursing Home Extension

Millbury Nursing Home is a purpose-built residential nursing home. The development will consist of a new fully serviced single storey extension, which doubles the capacity from 66 bedrooms to 132.

The works consist of a new extension incorporating 66 single bedrooms with associated nursing accommodation, visitor accommodation, administration and staff areas, dining & living facilities & all associated accommodation to ground floor level with associated alterations to elevations. Being able to deliver this extension quickly and with minimal disruption to the current residents was of the utmost importance.

Project Details

Project Size 1,400m2

Architect Michael Fitzpatrick Architects

Main Contractor S&A Construction Ltd

Installer

ADM Floor Screed

Product Grade TLA110 Grade

“We decided to use TLA on the Millbury Nursing Home extension as we could benefit from the speed of installation, zero material waste as there would be no cutting of insulated boards, remedial works around pipes / additional services would be removed and there would be no thermal loss via joints in rigid insulation board. The installation of the TLA product on our future projects is to be advised going forward. Energystore gave a detailed overview on the specification and delivered a professional product installation.”

Faster installation

Zero wastage

Thermal performance

Reduced labour

*Compared to traditional methods

Michael Fitzpatrick Architects

Technical Characteristics

Cement Dosage (kg/m3)

Density after 28 days (kg/m3)

Thermal Conductivity (W/mK)

Compressive Strength (kPa)

Flexural Strength (N/mm2)

Permeability to Water Vapour (μ)

Shrinkage (NBN) (mm/m)

energystore TLA® combines eps beads coated in a specially formulated additive with cement and water to create a pourable insulation. This poured insulation offers an A2 Fire Rated alternative for use in floor and roof construction as a high strength void former or insulation.

No on-site TLA storage or waste.

<0.5% drying shrinkage.

No gaps or breaks in insulation layer that may cause performance issues.

High strength poured insulation

Suitable for flat and sloping roofs

Suitable to apply underfloor heating systems (UFH) directly on top

Suitable for ground bearing and suspended floors

Faster installation compared to traditional methods A2 Fire Rated Insulation Solution