Skip to main content

2026 DTS BE Testing Capabilities

Page 1


DTS

Digital & Technical Services

BUILDING ENCLOSURE TESTING

BUILDING ENCLOSURE TESTING

Proven testing. Practical answers. Better buildings.

PaladinDTS provides data-driven enclosure testing to ensure your envelope is tight, durable, and ready for use. We help contractors and owners prevent surprises by identifying issues early and delivering clear, actionable guidance.

MEMBRANE & WATERPROOFING SYSTEMS

» Fluid-applied membranes

Mil thickness (wet/dry), adhesion pull testing, and installation verification.

» Self-adhered membranes

Adhesion testing and installation verification.

» Waterproofing systems

Adhesion testing, mil thickness, electronic leak detection, and visual inspection.

INSULATION & THERMAL PERFORMANCE

» Spray foam insulation

Density, adhesion, thickness, and installation verification.

» Thermal barrier thermography

Infrared imaging to identify voids, thermal bridging, and air leakage.

AIR BARRIER & AIRTIGHTNESS

» Whole-building pressurization

Measures overall airtightness and air barrier performance (blower doors).

» Component airtightness testing

Field chamber testing of windows, doors, and curtain walls.

WATER INTRUSION & ROOF SYSTEMS

» Water penetration

Verifies resistance of walls, windows, and assemblies to water intrusion.

» Roof systems

Thermography, electronic leak detection, and seam inspection.

David Burks (below) is one of two ABAA-certified auditors in Kentucky.

We help you confirm performance, resolve issues, and move forward with confidence.

DIAGNOSTIC INVESTIGATIONS (EXISTING BUILDINGS)

» Thermographic inspections

Identifies air leakage, moisture issues, and thermal anomalies.

» Leak investigations

Combines infrared, smoke tracing, and field testing to isolate sources of air and water infiltration.

PROJECT SUPPORT

» Document review & RFIs

Review drawings for continuity and constructability of enclosure systems.

» Pre-installation meetings

Clarify installation requirements, sequencing, and detailing before work begins.

EXAMPLES OF TESTS PERFORMED:

• Air Infiltration

» ASTM E783

• Water Penetration

» ASTM E1105, E2128, E331, and D5957

• Masonry Wall Drainage / Transition Material

• Whole-Building Air Leakage

» Using blower door with thermographic or smoke testing

» ASTM E1186, E779, E1827, and USACE 2012

• Thermographic Inspections

» Roof systems (ASTM C1153)

» Insulation systems (ASTM C1060)

• Spray Foam Insulation Verification

» Adhesion, thickness, and density of mediumdensity spray foam insulation

• Fluid-Applied Membrane Verification

» Adhesion and mil thickness

• Self-Adhered Membrane Verification

» Adhesion performance