WUR-COM+ Site Requirements

Page 1


Wur-Com+ Power and Transmission Requirements

Power Requirements:

Wur-Com+ System:

1. System Power:

• One (1) 110 VAC outlet within proximity of the elevator controller

2. Elevator Car to Machine Room Transmission:

• Two (2) Twisted Shield Pair Travel Cable wire from elevator Car to Controller

• Pair #1: Wur-Com+ data transmission and unit power to elevator cab via PoE

• Pair #2: Wur-Com+ data communication verification/failure notification.

3. System Transmission:

• A network or cellular connection to the elevator machine.

• Transmission path must have stand-by power for a minimum of four (4) hours in the event of a power outage.

Wur-Com+ Lobby Station or Machine Room Communication (if required)

• 110 VAC power at location of unit

• Ethernet connection at location of unit

• Four (4) hour stand by power integral to unit.

Transmission Requirements:

Ethernet:

• Recommended Speed: >100Mbps

• Back-up Power: UPS (minimum of 4 Hours) or Emergency Power Generator

• Network Port: Dynamic IP (system may be set-up with static IP Address requiring additional system configuration and set-up

• System MAC address provided at registration startup and in system/unit documentation

Cellular Network Requirements:

• Minimum Signal Strength: > 67 dBm (A consistently strong signal is required for the system to properly operate. Antenna may require adjustment or relocation to achieve signal)

(For larger elevator groups or facilities, we encourage contacting your Wurtec representative to assist with configuring the appropriate solution for the application.)