The SCR in Figure 1 below requires a 3 V trigger. Using Multisim, design a system by which the gears are shifted when a CdS photocell resistance drops below 4k. Using Multisim, design a system by which a control signal of 4 to 20 mA is converted into a force of 200 to 1000N. Use a pneumatic actuator and specify the required diaphragm area if the pressure output is to be in the range of 20 to 100kPa. An I/P converter is available that converts 0 to 5 V into 20 to 100 kPa. A block diagram of the system is shown below. (Hint: Use a differential amplifier. You are only designing the circuit to interface into the I/P below)

Paper For Above instruction

The system described involves two primary engineering challenges: designing a triggering circuit for an SCR based on photocell resistance, and creating a control circuit that converts a current signal into a force applied by a pneumatic actuator. Both require a clear understanding of electronic circuit design, sensor interfacing, and pneumatic system calculations.

Designing the SCR Trigger Circuit

Based on Photocell Resistance

The first task involves designing a trigger circuit for an SCR, which requires a gate voltage of approximately 3 V, to initiate conduction. The control condition is triggered when a CdS photocell resistance drops below 4kΩ, indicating sufficient light intensity. The photocell acts as a light-dependent resistor (LDR); its resistance decreases as illumination increases.

The circuit design involves converting the resistance change into a voltage signal capable of triggering the SCR. A common approach employs a voltage divider composed of the photocell and a fixed resistor. The voltage across the fixed resistor can be monitored and used to trigger the SCR via a comparator or a transistor switching circuit.

Specifically, the voltage divider is configured as follows: when the photocell resistance drops below 4kΩ, the voltage at the divider's output exceeds a set threshold, which then triggers the SCR. To ensure a 3 V trigger, a transistor switch or operational amplifier comparator can compare this voltage to a reference, switching the SCR gate accordingly. The designed circuit must be simulated in Multisim to verify the threshold at which the SCR fires accurately when the photocell resistance crosses 4kΩ.

The key components include the photocell (CdS sensor), a fixed resistor, an operational amplifier or

comparator, and the SCR. The resistor value is chosen based on the photocell's maximum resistance (around several tens of kilo-ohms in darkness) and the desired threshold voltage. The circuit is powered by an appropriate DC supply, typically 5 V or 12 V, ensuring the SCR and control circuitry operate within their voltage ratings.

Designing the Control Signal Conversion from 4-20 mA to Force

The second part involves converting a 4-20 mA control signal into a force ranging from 200 to 1000 N, utilizing a pneumatic actuator. The process requires an interface circuit, generally a current-to-voltage converter, that feeds into an I/P converter. The I/P converter then translates the voltage signal into a proportional pneumatic pressure, which acts on the actuator's diaphragm.

The system diagram indicates the use of a differential amplifier to convert the control current into a voltage signal compatible with the I/P converter input range (0-5 V). The key calculation involves establishing a transfer function connecting the current range (4-20 mA) to the desired force (200-1000 N).

The force is directly related to pneumatic pressure, which is determined by the diaphragm area and the pressure applied.

Given the pressure range of 20-100 kPa, the diaphragm area must be calculated to produce the required force at maximum pressure. Using the relation: Force = Pressure × Area, rearranged as Area = Force / Pressure. For a maximum force of 1000 N at 100 kPa, the diaphragm area should be:

Area = 1000 N / 100,000 Pa = 0.01 m² or 100 cm².

Similarly, at the minimum force of 200 N and minimum pressure of 20 kPa, the area should be:

Area = 200 N / 20,000 Pa = 0.01 m², confirming the same diaphragm size suffices for the entire range.

The differential amplifier converts the current from the control signal into a voltage. Using a typical transimpedance amplifier configuration, the resistor setting determines the voltage output for the 4-20 mA input. For instance, a resistor of 250 Ω will produce 1 V at 4 mA and 5 V at 20 mA, matching the 0-5 V input range for the I/P converter.

This voltage output interfaces into the I/P converter, which then produces the pneumatic pressure in the specified range. The pressure is then applied to the diaphragm, producing the force needed to operate the actuator accordingly.

Conclusion

In conclusion, the system integrates sensor circuitry, signal conditioning, and pneumatic actuation design principles. The photocell-based trigger circuit requires precise threshold detection, implemented with a voltage divider and comparator in Multisim, ensuring the SCR fires at the designated light level. The current-to-force conversion involves a differential amplifier and an I/P converter, with calculations confirming the diaphragm size needed. This comprehensive approach ensures reliable automation control tailored to specified operational thresholds.

References

Sedra, A. S., & Smith, K. C. (2014). Microelectronic Circuits (7th Edition). Oxford University Press.

Boylestad, R. L., & Nashelsky, L. (2013). Electronic Devices and Circuit Theory (11th Edition). Pearson.

Nise, N. S. (2015). Control Systems Engineering (7th Edition). Wiley.

Ogata, K. (2010). Modern Control Engineering (5th Edition). Prentice Hall.

Dorf, R. C., & Svoboda, J. A. (2010). Introduction to Electric Circuits (8th Edition). Wiley.

Kuo, B. C., & Golnaraghi, F. (2009). Automatic Control Systems (9th Edition). Wiley.

Hartman, E. P., & Soni, B. K. (2009). Instrumentation and Process Control. McGraw-Hill Education.

U. S. Army Corps of Engineers. (2007). Pneumatic and Hydraulic Control Systems. Engineering Manuals. National Instruments. (2013). NI Multisim 14. Educational Resources for Circuit Simulation. IEEE Standard for Control Systems Interface. IEEE Std 1012-2017.