DPV vertical multistage pumps nema - technical data dp pumps

Page 1

Multi-stage centrifugal pumps DPV ASME / NEMA

Technical specification booklet series: DPV(C/S) 2 - 4 - 6 - 10 - 15 - 25 - 40 - 60 - 85 - 125 60Hz


2


Table of Contents 1

2

3

4

Pump introduction

1.1 1.2 1.3 1.4 1.5 1.6 1.7 1.8 1.9

General .................................................................................................................................................. 5 Model key............................................................................................................................................... 5 Operation ............................................................................................................................................... 6 Measuring, draining and venting............................................................................................................ 6 Working range........................................................................................................................................ 6 Basic material variants........................................................................................................................... 7 Pump bearing......................................................................................................................................... 7 Modular selection................................................................................................................................... 8 Approvals ............................................................................................................................................... 8

Performance characteristics

2.1 2.2 2.3 2.4 2.5

Performance range ................................................................................................................................ 9 Performance curve details ..................................................................................................................... 9 Minimum efficiency index..................................................................................................................... 10 Performance with variable frequency drive.......................................................................................... 10 How to read the values from the curves ...............................................................................................11

Curves and dimensions

3.1 3.2 3.3 3.4 3.5 3.6 3.7 3.8 3.9 3.10 3.11 3.12 3.13 3.14 3.15 3.16 3.17 3.18 3.19 3.20 3.21 3.22

Hydraulic performance curve DPV 2 B - 60Hz -2 pole (3500 rpm) ...................................................... 13 Hydraulic performance curve DPV 4 B - 60Hz - 2 pole (3500 rpm) ..................................................... 14 Hydraulic performance curve DPV 6 B - 60Hz - 2 pole (3500 rpm) ..................................................... 15 Hydraulic performance curve DPV 10 B - 60Hz - 2 pole (3500 rpm) ................................................... 16 Hydraulic performance curve DPV 15 C - 60Hz - 2 pole (3500 rpm)................................................... 17 Hydraulic performance curve DPV 25 B - 60Hz - 2 pole (3500 rpm) ................................................... 18 Hydraulic performance curve DPV 40 B - 60Hz - 2 pole (3500 rpm) ................................................... 19 Hydraulic performance curve DPV 60 B - 60Hz - 2 pole (3500 rpm) ................................................... 20 Hydraulic performance curve DPV 85 B - 60Hz - 2 pole (3500 rpm) ................................................... 21 Hydraulic performance curve DPV 125 B - 60Hz - 2 pole (3500 rpm) ................................................. 22 Hydraulic performance curve DPLHS 6 - 60Hz - 2 pole (3500 rpm) .................................................... 23 Dimensions DPV 2 B ........................................................................................................................... 24 Dimensions DPV 4 B ........................................................................................................................... 26 Dimensions DPV 6 B ........................................................................................................................... 28 Dimensions DPV 10 B ......................................................................................................................... 30 Dimensions DPV 15 C ......................................................................................................................... 32 Dimensions DPV 25 B ......................................................................................................................... 34 Dimensions DPV 40 B ......................................................................................................................... 36 Dimensions DPV 60 B ......................................................................................................................... 38 Dimensions DPV 85 B ......................................................................................................................... 40 Dimensions DPV 125 B ....................................................................................................................... 42 Dimensions DPLHS 6 .......................................................................................................................... 44

Low NPSH impeller

4.1 4.2 4.3 4.4 4.5 4.6 4.7 4.8 4.9

General ................................................................................................................................................ 46 Risks of cavitation: ............................................................................................................................... 46 Benefits of using low NPSH impeller: .................................................................................................. 46 Consequences by using a low NPSH impeller:.................................................................................... 46 Calculation of NPSHa .......................................................................................................................... 46 Low NPSH grafiek DPV(C/S) 2 B - 60Hz - (3500 rpm) ........................................................................ 48 Low NPSH grafiek DPV(C/S) 4 B - 60Hz - (3500 rpm) ........................................................................ 49 Low NPSH grafiek DPV(C/S) 6 B - 60Hz - (3500 rpm) ........................................................................ 50 Low NPSH grafiek DPV(C/S) 10 B - 60Hz - (3500 rpm) ...................................................................... 51

3


4.10 Low NPSH grafiek DPV(C/S) 10 B - 60Hz - (1750 rpm) ...................................................................... 52 4.11 Low NPSH grafiek DPV(C/S) 15 C - 60Hz - (3500 rpm)...................................................................... 53 4.12 Low NPSH grafiek DPV(C/S) 15 C - 60Hz - (1750 rpm)...................................................................... 54

5 6 7 8

4

Seals

5.1

Mechanical seal option specifications.................................................................................................. 55

Motors

6.1

General ................................................................................................................................................ 56

Materials

7.1

Parts overview ..................................................................................................................................... 57

Medium handled

8.1

Medium handled .................................................................................................................................. 59


1

Pump introduction

1.1

General

DPV2-4-610-15 B & 15 C

1.2

The vertical, single or multi-stage centrifugal pump series are designed for pumping clean, or lightly aggressive, watery mediums. Suction and discharge of the pump are in-line, making the pump easy to install. The hydraulic assembly is driven by an electric motor. All hydraulic parts of the pump are made of stainless steel. The vertical, multi-stage centrifugal DPV pumps are produced by DP-Pumps.

DPV25- 4060 B

DPV 85B - 125

Model key

Table 1: Model key Example DPVSF 85/3-1 B DP VS F Label Material/Construction

85 /3 -1 B

DP

Product Label VC

Cast Iron pump foot and top bracket, hydraulics AISI 304

V

All wetted parts Stainless Steel 1.4301 / AISI 304

VS Connection

All wetted parts Stainless Steel 1.4401 / AISI 316 F

Round flange Capacity in m3/h at Q.opt. (in m3/h)

85 /3

Number of stages -1 L

Number of stages of which reduced impeller Low NPSH impeller (model 2, 4, 6, 10 and 15) B/C Design version

5


1.3

Operation

1.4

Measuring, draining and venting

The pump is provided with plugs for measuring, draining and venting. Connection (E) is meant to drain the inlet part of the pump. Or to measure the inlet / suction pressure using a G ¼ connection. Connection (F) is meant to drain the outlet part of the pump. Or to measure the discharge pressure using a G ¼ connection. Connections (G) are meant to vent the pump system when the pump is not in operation. Or to measure the discharge pressure of the pump using a G 3/8 connection.

ID3027

1.5 G

G

Working range

The working range is depending on the application and a combination of pressure and temperature. The overall working range of the pumps can be summarised as follows: Table 2: Specification of the working range Pump type

B

DPV

Ambient temperature [°F]

C

Minimum inlet pressure Viscosity [cSt] Density

E

Figure 1: DPVF 85

6

F

]

Cooling

D

20080190 A

A

[lbs/ft3

During centrifugal operation of the pump a negative pressure is created at the inlet of the impeller. This negative pressure enables the medium to enter the pump at the suction connection (A). Every stage (B) consists of an impeller and diffuser. The passage of this stage determines the capacity of the pump. The diameter of the stages is related to the centrifugal forces and its “stage pressure”: the more stages, the more pressure. This total capacity and raised pressure will be guided to the outside of the pump, between the pump stages and the outer sleeve (C) and the medium will leave the pump at the discharge connection (D).

note -4 up to 104

NPSHreq. + 3ft 1-100

2

62-156

2

forced motor cooling

3

Minimum frequency [Hz]

30

Maximum frequency [Hz]

60

Allowable size of solids pumped 1.

2.

3.

4.

1

4

2500 to 18 Mesh

If the ambient temperature exceeds the above value or the motor is located more than 3280 ft above sea level, the motor cooling is less effective and could require an adapted motor power. See table 5: Motor load dep. sea level or amb. temp or please contact your supplier for more detailed advice. Deviation in viscosity and/or density could require an adapted motor power. Please contact your supplier for more detailed advice. The free space above the motor cooling fan must be at least 1/4 of the diameter of the inlet of the cooling fan in order to have a sufficient flow of (cooling) air. Pumps that are intended for 50 Hz operation, may not be connected to 60 Hz power supply.


1.5.1

Minimum capacity

Table 5: Increase of required motor power

For minimum capacity at medium temperature of 68 oF, see below table 3. In case of higher medium temperatures, see table 4. To prevent the pump from overheating, gathering gas, cavitation etc. a minimum capacity has to be secured. The minimum capacity corresponds to al percentage of the optimum flow Qopt in relation to the temperature of the liquid pumped.

Ambient temperature [°F]

Above sea level [ft]

Increase of required power

104

3280

0%

113

5330

2%

122

7382

5%

131

9432

11%

140

11483

18%

149

13530

25%

158

15584

33%

Table 3: Minimum capacity (Qmin) in 60Hz

1.6

size Qmin [GPM]

Basic material variants

2

0.9

4

2.2

Model

Hydraulic

Casing

Sealing

6

3.5

V

1.4301

1.4308

EPDM

10

5.7

VS

1.4404

1.4408

FPM

15

8.8

VC 2-60 & 125

1.4301

JS1030

EPDM

25

14.1

VC 85

1.4301

JL1040

EPDM

40

21.1

60

31.7

85

44.9

125

69.9

1.7

Table 4: Minimum capacity vs.temperature (in % of Q optimum)

Medium lubricated stage bearing Tungsten Carbide against Ceramic Optional pump bearing Tuc/TuC

ID3675

40

Pump bearing

Q [%]

In case of severe applications or using conditions, such as hot water, boiler feed (max 140°C) or when the pump experiences un avoidable dry running for a short time. The standard ceramic bearing material can be replaced / exchanged by a more resistant TuC/TuC bearing material.

35 30 25 20 15 10 5

104

122

140

158

176

194

212

230

248

266

284

T [oF]

1.5.2

3675

0

Ambient temperature and higher altitude If the ambient temperature exceeds the above value, or if the motor is located more than 3280ft above sea level, the motor cooling is less effective and could require an adapted motor power. See below table for the increased percentage of the motor power or contact your supplier for more detailed advice.

Due to the specific material characteristics of Tungsten Carbide, the TuC/TuC material is even more resistant for the above mentioned severe conditions and will enhance the durability and lifecycle of the pump. When combining the use of the optional TuC/TuC bearing material and the optional low NPSH kit, the pump can be made even more suitable for the above mentioned severe applications or using conditions. The optional combinations TuC/TuC bearing material and low NPSH kit are available for the vertical pump models DPVCF 2, 4, 6, 10 and 15. Up to now only the optional TuC/TuC bearing material is available for the larger pump models DPVCF 25, 40, 60, 85 and 125. For other possible pump options or features, please contact our sales department. .

7


1.8

Modular selection

To suit almost every application the pump is assembled out of modules which can be selected depending on the required working range. Basic modules are:

• • •

1.9 CE NSF

8

Basic pump model, which defines the capacity, pressure and basic material. Temperature range -4 up to 284 °F, with the exception of the DPV 125 this pump can be used upto 248 °F. Connections, which define the suction and discharge connection as well as the base plate. Sealings, which define the elastomers, the mechanical seal and the shaft seal type. Electric motor, which defines all requirements of the motor such as motor size, power, voltage, frequency and all possible motor accessories.

Approvals Conformity with European Safety Directive Drinking water approval


2

Performance characteristics

2.1

Performance range

ID3440

Figure 2: Performance range DPV(C/S) B/C 60 Hz

2.2

Performance curve details

The performance diagrams give a global overview of all the pump models the shaded models are mentioned in this documentation. Detailed characteristics are given for each model showing the hydraulic efficiency, NPSHreq, and shaft power as well. The performance of the pump depends on the number of stages. As per example:

DPV 4/2 B

model DPV 4 B

DPV 85/4-1 B model DPV 85 B

2 stages with 2 full head impellers 4 stages with 3 full head impellers and 1 reduced impeller

The detailed performance curves are in accordance with ISO 9906: 2012 (Grade 3B). The motors used for the measurements are calibrated motors with a specific rotational speed. Therefore the performance data, like Q/H, efficiency and shaft power used for published curves are converted to the average speed per motor power. To refine this data the published data has to be corrected accordingly.

9


The published curves and data mentioned on the pump is based on a rotational speed of 3500 rpm for 2P motors. The maximum required power for the hydraulics to cover the curve (run-out performance) is mentioned on the name plate of the pump. This power corresponds to above mentioned rated speeds. In the pump curves also the required hydraulic power on a specific duty point can be determined. In case of using a motor with another rated speed as mentioned in the table, please recalculate the required power according the formula in figure 3. To cover the required hydraulic power all pumps are pre-equipped with a support flange to fit the specific rated motor power, see pump data. In some cases on this rated power it will be necessary to use a part of the common motor service factor*) to cover the “runout performance” of the pump. In those cases to a maximum of 15% on the rated power will be required. As the pumps apply to ISO9906:2012 Grade 3B tolerances we recommend to use motors which have a 1.25 service factor. *) The service factor is the allowed exceeded power of the motor rated power which may be used incidentally. Per motor brand this value can differ and therefore needs to be checked before installation. The characteristics given are based on: • De-aerated water at a temperature of 68 °F • Density of 62 lbs/ft3 • Kinematic viscosity of 1 cSt To prevent the pump from overheating, gathering gas, cavitation etc.a minimum capacity has to be secured. The minimum capacity corresponds to a percentage of the optimum flow Qopt in relation to the temperature of the liquid pumped.

2.3

10

Minimum efficiency index

The minimum energy-efficiency level according to the ErP regulations for water pumps is specified by the minimum efficiency index MEI. A high MEI value indicates a high efficiency of the determined pump. From 1 January 2015 on the minimum efficiency index (MEI) for standardised water pumps is ≥ 0.4. For the DPV pump ranges the following values are applicable:

Table 6: Minimum efficiency index Pump range

Minimum Efficiency index

DPV 2B

MEI ≥ 0.70

DPV 4B

MEI ≥ 0.70

DPV 6B

MEI ≥ 0.70

DPV 10B

MEI ≥ 0.70

DPV 15C

MEI ≥ 0.70

DPV 25B

MEI ≥ 0.70

DPV 40B

MEI ≥ 0.70

DPV 60B

MEI ≥ 0.70

DPV 85B

MEI ≥ 0.60

DPV 125B

MEI ≥ 0.70

DPLHS 6

MEI ≥ 0.60

2.4

Performance with variable frequency drive

The minimum frequency of the motor should be limited to 30 Hz. When the rotational speed exceeds the nominal speed of the motor, make sure that the power output of the motor is suitable to drive the corresponding pump model. The performance of the pump differs from the fixed speed performance according to the recalculation scheme.


ID3238

H

Q2

H1

n2 Q1 n1

n1

H2 n2

1

H2

n2

2

n1

2

H1

Q

2

hydr.

n1

n2

2

1

1

1

n1 n2

0. 1 0. 1

Q P/st. n1

3

P2

n2

n2 n1

3 3

P1

Q n1

NPSH 2

n2

Q2 Q1

Q

Figure 3: Performance characteristics

2.5

n2 n1

2 2

NPSH1

3238/08072008

4

NPSH req.

How to read the values from the curves

To find the required hydraulic information from the published curves, it is important to know the application in which the pump has to be installed. There are two main distinction to be made: A Flow determined (like booster sets and cleaning) Opening taps B Pressure determined (like boiler feed and reverse osmosis systems) Facing counter pressure.

How to read the motor power. The required motor power can be read in the curve’Power input’. Attention: the power value as mentioned in this curve is the required power per stage. For some pump types there are two lines in the curve this is related to the full impeller or reduced impeller [-1].

11


3227

Pump size / no of stages. Installed motor power Capacity @ Pressure

NPSH (m)

Hydraulic efficiency (%)

Figure 4: How to read the values from the curves O  A B

12

Calculated duty point Actual hydraulic performance Flow determined Pressure determined

3227/04072008

Required power (P2)


3

Curves and dimensions

3.1

Hydraulic performance curve DPV 2 B - 60Hz -2 pole (3500 rpm)

0

1

0.0

0.2

2

[m³/h] [l/s]

0.4

3 0.6

4

0.8

1.0

2/22 5 hp

250

800 2/20 5/3* hp

700 2/18 5/3* hp

200 600 2/16 3 hp

2/14 3 hp Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

500

150 2/12 3/2* hp 2/11 2 hp

400

2/10 2/1.5* hp 2/9 2/1.5* hp

100 300

2/8 1.5 hp 2/7 1.5/1* hp

[m]

2/6 1.5/1* hp

200 2/5 1/0.75* hp [ft]

50

2/4 0.75 hp 2/3 0.75/0.5 hp

100

2/2 0.5 hp

0

0 0

2 [US.gpm] 4

0

6

8

10 [IM.gpm]

5

12

14

16

10

18 15

30 NPSHR

[ft]

5 [m]

0

0

60 Eta

%

13

0 0.2 0.1 [kW]

[hp]

0.0

0.0 0

ȡ = 1000.0 kg/m³

2 [US.gpm] 4

6

8

10

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 5: Performance curve DPV 2 B - 60Hz - 2 pole

12

14

16

18 20100695-E/0

20100695 E

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.


3.2

Hydraulic performance curve DPV 4 B - 60Hz - 2 pole (3500 rpm)

0

2

0.0

0.5

4

[m³/h] [l/s]

6

1.0

8

1.5

2.0

800 4/18 7.5 hp

700 4/16 7.5/5* hp 200 600

4/14 7.5/5* hp

4/12 5 hp

500

150

4/11 5 hp Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

4/10 5/3* hp

400 4/9 5/3* hp 4/8 3 hp

300

100

4/7 3/2* hp 4/6 3/2* hp

[m] 4/5 2/1.5* hp

200 4/4 1.5 hp

[ft]

50 4/3 1.5/1* hp

100 4/2 0.75 hp

0 0

5

0

[US.gpm] 10

0

15

20 [IM.gpm]

10

25

30

35

20

30

20 NPSHR

[ft]

5 [m]

0

0

80 Eta

%

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

0.4

14

0

0.2 [hp] [kW] 0.0

0.0

ȡ = 1000.0 kg/m³

5 [US.gpm] 10

15

20

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 6: Performance curve DPV 4 B - 60Hz - 2 pole

25

30

35 20100696-D/0

20100696 D

0


3.3

Hydraulic performance curve DPV 6 B - 60Hz - 2 pole (3500 rpm)

0

2

4

[m³/h]

0

6

1

8

10

2

[l/s]

3

6/18 10 hp

250 800 6/16 10/7.5* hp

200

6/14 7.5 hp

600 6/12 7.5 hp

Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

6/11 7.5/5* hp

150 6/10 5 hp 6/9 5 hp

400 6/8 5 hp 6/7 5 hp

[ft]

100

6/6 3 hp

[m]

6/5 3 hp

200 6/4 2 hp 50

6/3 1.5 hp 6/2 1 hp 6/1 0.5 hp

0 0

[US.gpm]

10

0

10

0 20

[IM.gpm]

30 20

40 30

50 40

20 NPSHR

6 [m]

[ft]

0

0 80 Eta

%

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

0.5

15

0 0.3 [kW]

[hp]

0 ȡ = 1000.0 kg/m³

10

[US.gpm]

0.0 20

30

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 7: Performance curve DPV 6 B - 60Hz - 2 pole

40

50 20100697-C/0

20100697 C

0.0


3.4

Hydraulic performance curve DPV 10 B - 60Hz - 2 pole (3500 rpm)

0

5

0

1

10

[m³/h] 2

[l/s]

15 3

4 250

800 10/15 15 hp

700 10/13 15/10* hp 200 600 10/11 10 hp 10/10 10/7.5* hp

Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

500 10/9 10/7.5* hp

150

10/8 7.5 hp

400 [ft]

10/7 7.5 hp

[m] 10/6 7.5/5* hp

100

300 10/5 5/3* hp 10/4 5/3* hp

200 10/3 3 hp

50

10/2 2/1.5* hp

100 10/1 1/0.75* hp

0

0 0

10 [US.gpm] 20

0

30

40 [IM.gpm]

20

50

60

70

40

60

20 NPSHR

[ft]

5 [m]

0

0

80 Eta

16

% 0 1 0.6 [kW]

[hp] 0 0

ȡ = 1000.0 kg/m³

10 [US.gpm] 20

0 30

40

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 8: Performance curve DPV 10 B - 60Hz- 2 pole

50

60

70 20101088-B/0

20101088 B

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.


3.5

Hydraulic performance curve DPV 15 C - 60Hz - 2 pole (3500 rpm)

0

10

0

2

20

[m³/h] 4

[l/s]

6

800 15/11 25 hp

15/10 25 hp

700 15/9 20 hp

600

200

15/8 20 hp

15/7 20 hp

500 Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

150 15/6 15 hp

400 15/5 15 hp

100 300 15/4 10 hp [m] 15/3 7.5 hp

200 [ft]

50

15/2 5 hp

100

15/1 3 hp

0 0 0

20 20

[IM.gpm]

0 40

[US.gpm] 40

60 60

80 80

100 100

120

15 NPSHR

4 [m]

[ft]

0

0 80 Eta

%

17

0 1.5

2

[kW]

[hp] 0 0

ȡ = 1000.0 kg/m³

20

[IM.gpm]

0 40

60

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 9: Performance curve DPV 15 C - 60Hz - 2 pole

80

100 20210133-A/0

20210133 A

Leistungsbedarf* Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.


3.6

Hydraulic performance curve DPV 25 B - 60Hz - 2 pole (3500 rpm)

0

10

0

2

[l/s]

20

[m³/h] 4

30 6

40

8

10

12

700 25/7 30/25* hp

200

600 25/6 25/20* hp

500

150

25/5 5 20 0 hp

Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

400

25/4 20/15* hp

100 300 25/3 15/10* hp [m] 200 25/2 10/7.5* hp 50

[ft] 1 5 hp h 100 25/1

0

0

20

0

40

60 80 [US.gpm]

100 [IM.gpm]

50

120

140

160

100

180

0 200

150

30 NPSHR

[ft]

5 [m]

0

0

80 Eta

0 Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

5 3 [hp]

[kW] 1

1 0

ȡ = 1000.0 kg/m³

20

40 60 [US.gpm]

80

100

120

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 10: Performance curve DPV 25 B - 60Hz - 2 pole

140

160

180

200

20120481-C/0

20120481 C

18

%


3.7

Hydraulic performance curve DPV 40 B - 60Hz - 2 pole (3500 rpm)

0

20

0

5

40

[m³/h] [l/s]

60

10

15

700 40/6 50 hp 200

40/6-2 50/40* hp

600

40/5 40 hp 40/5-2 40 hp

500

150

40/4 40/30* hp 40/4-2 30/25* hp Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

400 40/3 25 hp

100

40/3-2 25/20* hp

300 40/2 20/15* hp

[m]

200 40/2-2 15 hp 50

[ft] 40/1 10/7.5* hp

100 40/1-1 7.5 hp

0 0 0

0

[US.gpm] 100

50 50

[IM.gpm]

150 100

200 150

250

300

200

250

30 NPSHR

5 [m]

[ft]

0

0 100 Eta

%

19

0 8

[kW]

0 0

ȡ = 1000.0 kg/m³

4

-1

[hp]

50

[US.gpm] 100

0 150

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 11: Performance curve DPV 40 B - 60Hz - 2 pole

200

250

300 20131184-B/0

20131184 B

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.


3.8

Hydraulic performance curve DPV 60 B - 60Hz - 2 pole (3500 rpm)

0 0

20

40

[m³/h]

5

[l/s]

60

10

80

15

20

25

700 60/5 60 hp 200 60/5-2 60/50* hp

600 60/4 50 hp

500

150

60/4-2 40 hp

Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

60/3 40 hp

400

60/3-2 30/25* hp

100 300

60/2 25 hp

[m] 200

60/2-2 20/15* hp

50

[ft] 60/1 15 hp 100

60/1-1 10/7.5* hp

0 0

[US.gpm]

100

0

100

0 200

[IM.gpm]

300 200

400 300

30 NPSHR

[ft]

5 [m]

0

0

100 Eta

%

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

15

20

0 10

[hp]

-1

0 ȡ = 1000.0 kg/m³

100

[US.gpm]

0 200

300

Fördermenge/Flow/Debit/Portata/Capaciteit/Caudal

Figure 12: Performance curve DPV 60 B - 60Hz - 2 pole

400 20131185-B/0

20131185 B

0

[kW]


3.9

Hydraulic performance curve DPV 85 B - 60Hz - 2 pole (3500 rpm)

0

50

0

10

100

[m³/h] [l/s]

20

30

40

500

150

85/4-2 60/50* hp

85/3 60/50* hp

400 85/3-1 50/40* hp 85/3-2 40 hp

100 Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

300 85/2 40/30* hp 85/2-1 30/25* hp

[m]

85/2-2 25 hp

200 50 [ft]

85/1 20/15* hp 85/1-1 15 hp

100

0

0 0 0

100 [US.gpm] 200 100

[IM.gpm]

300 200

400 300

500 400

600 500

30 NPSHR

[ft]

5 [m]

0

0

100 Eta

%

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

20

21

0

-1

[hp]

[kW]

100

[US.gpm] 200

0 300

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 13: Performance curve DPV 85 B - 60Hz - 2 Pole

400

500

600 20100698-D/0

20100698 D

0 0

ȡ = 1000.0 kg/m³

10


3.10

Hydraulic performance curve DPV 125 B - 60Hz - 2 pole (3500 rpm)

0

50

0

100

[m³/h] 20

150

200

40

[l/s]

125/2 60 hp

350

100

300

80 250 125/2-2 40 hp Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

200

60 125/1 30 hp

[m] 150 40

[ft]

100

20 50

0

[US.gpm]

200

0

200

400

[IM.gpm]

600 400

800 600

60 NPSHR

10 [m] 0

[ft] 0 100

Eta

%

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

30

22

0 20 -1

[hp]

0 ȡ = 1000.0 kg/m³

200

[US.gpm]

0 400

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 14: Performance curve DPV 125 B - 60Hz - 2 Pole

600

800 20150418-B/0

20150418 B

0

[kW]


3.11

Hydraulic performance curve DPLHS 6 - 60Hz - 2 pole (3500 rpm)

86 JSP

,0 JSP

+3

+3

)|UGHUK|KH 7'+ +DXWHXU 3UHYDOHQ]D 2SYRHUKRRJWH $OWXUD

+3

IW

P

136+5

Pñ K O V

IW

P

(WD

/HLVWXQJVEHGDUI 3RZHU ,QSXW 3XLVV DEV 3RWHQ]D DVV 2SJHQRPHQ YHUPRJHQ 3RWHQFLD QHF

23 KS

N:

Pñ K

)|UGHUPHQJH )ORZ 'pELW 3RUWDWD &DSDFLWHLW &DXGDO

Figure 15: Performance curve DPLHS 6 - 60Hz - 2 pole

%

97000925 B


3.12

Dimensions DPV 2 B

Table 7: Layout and connections

optional: 1”

optional: 1”

optional: 1”

optional: 1”

Standard DPV(C/S)F Collar flanges in cast iron Norm: ASME B16.1 Size: 1.25” (NPS 5/4) Pressure Class: 250# Option: base plate in AISI304

Optional DPV(S)F Collar flange in AISI304 Norm: ASME B16.5 Size: 1.25” (NPS 5/4) Pressure Class: 300# Option: base plate in AISI304

Optional DPV(S) Counter flange with female thread in cast stainless steel Norm: ASME B1.20.1 Size: NPT 1” Pressure Class: 150# Option: base plate in AISI304

24


Table 8: Standard motor power - Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

F1 [inch]

Bare shaft mass

Mass with motor*

F2 [inch]

[lbs]

[lbs]

2/2

56C

0.5

6.625

5.000

6.500

21.51

12.00

31

50

20.53

11.02

15

34

2/3 #

56C

0.75

6.625

5.000

6.500

22.33

12.83

32

53

21.35

11.85

16

37

2/4

56C

0.75

6.625

5.000

6.500

23.20

13.70

33

54

22.22

12.72

17

38

2/5 #

56C

1

6.625

5.250

6.500

24.03

14.53

34

55

23.05

13.55

18

39

2/6 #

143TC

1.5

6.625

5.250

6.500

25.14

15.39

35

65

24.16

14.41

20

49

2/7 #

143TC

1.5

6.625

5.250

6.500

26.23

16.22

36

66

25.24

15.24

20

50

2/8

143TC

1.5

6.625

5.250

6.500

26.84

17.09

37

67

25.86

16.11

21

51

2/9 #

145TC

2

6.625

5.250

6.500

28.54

17.91

38

71

27.56

16.93

22

55

2/10 #

145TC

2

6.625

5.250

6.500

30.28

18.78

39

72

29.30

17.80

23

56

2/11

145TC

2

6.625

5.250

6.500

30.23

19.61

41

73

29.25

18.63

24

57

2/12 #

182TC

3

7.875

5.875

9.000

31.60

20.47

42

91

30.62

19.49

25

75

2/14

182TC

3

7.875

5.875

9.000

34.06

23.03

43

93

33.18

22.05

27

77

2/16

182TC

3

7.875

5.875

9.000

35.85

24.72

45

95

34.87

23.74

29

79

2/18 #

184TC

5

7.875

5.875

9.000

40.29

26.42

47

116

39.31

25.44

31

100

2/20 #

184TC

5

7.875

5.875

9.000

41.99

28.11

52

121

41.0

27.13

36

105

2/22

184TC

5

7.875

5.875

9.000

43.68

29.80

54

123

42.70

28.82

38

107

# Pump type optional with decreased motor power Table 9: Decreased motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

F1 [inch]

Bare shaft mass

Mass with motor*

F2 [inch]

[lbs]

[lbs]

2/3 #

56C

0.5

6.625

5.000

6.500

22.33

12.83

32

51

21.35

11.85

16

35

2/5 #

56C

0.75

6.625

5.250

6.500

24.03

14.53

34

55

23.05

13.55

18

39

2/6 #

56C

1.0

6.625

5.250

6.500

24.89

15.39

35

65

23.91

14.41

20

49

2/7 #

56C

1.0

6.625

5.250

6.500

25.97

16.22

36

66

24.99

15.24

20

50

2/9 #

143TC

1.5

6.625

5.250

6.500

27.66

17.91

38

68

26.68

16.93

22

52

2/10 #

143TC

1.5

6.625

5.250

6.500

29.40

18.78

39

69

28.42

17.80

23

53

2/12 #

145TC

2

6.625

5.250

6.500

31.10

20.47

42

74

30.62

19.49

25

58

2/18 #

182TC

3

7.875

5.875

9.000

37.54

26.42

47

97

36.56

25.44

31

81

2/20 #

182TC

3

7.875

5.875

9.000

39.24

28.11

52

102

38.26

27.13

36

86

25


3.13

Dimensions DPV 4 B

Table 10: Layout and connections

optional: 1”

optional: 1”

optional: 1”

optional: 1”

Standard DPV(C/S)F Collar flange in cast iron Norm: ASME B16.1 Size: 1.25” (NPS 5/4) Pressure Class: 250# Option: base plate in AISI304

Optional DPV(S)F Collar flanges in AISI304 Norm: ASME B16.5 Size: 1.25” (NPS 5/4) Pressure Class: 300# Option: base plate in AISI304

Optional DPV(S) Counter flange with female thread in cast stainless steel Norm: ASME B1.20.1 Size: NPT 1” Pressure Class: 150# Option: base plate in AISI304

26


Table 11: Standard motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

F1 [inch]

[lbs]

[lbs]

F1 [inch]

E2 [inch]

P [inch]

F2 [inch]

F2 [inch]

Bare shaft mass

Mass with motor*

[lbs]

[lbs]

4/2

56C

0.75

6.625

5.000

6.500

21.51

12.00

31

52

20.53

11.03

15

36

4/3 #

143TC

1.5

6.625

5.250

6.500

22.84

12.83

33

63

21.85

11.85

17

47

4/4

143TC

1.5

6.625

5.250

6.500

23.45

13.70

33

63

22.47

12.72

17

47

4/5

145TC

2

6.625

5.250

6.500

25.16

14.53

34

67

24.18

13.55

18

51

4/6 #

182TC

3

7.875

5.875

9.000

26.52

15.39

35

85

25.54

14.41

20

69

4/7

182TC

3

7.875

5.875

9.000

28.22

17.09

36

86

27.24

16.11

20

70

4/8

182TC

3

7.875

5.875

9.000

29.08

17.95

37

87

28.10

16.98

21

71

4/9 #

184TC

5

7.875

5.875

9.000

32.66

18.78

42

111

31.67

17.80

26

95

4/10

184TC

5

7.875

5.875

9.000

33.52

19.65

43

112

32.54

16.67

27

96

4/11

184TC

5

7.875

5.875

9.000

34.35

20.47

44

113

33.67

19.49

28

97

4/12

184TC

5

7.875

5.875

9.000

35.21

21.34

45

114

34.23

20.36

29

98

4/14 #

213TC

7.5

9.562

7.375

9.000

38.28

23.03

46

168

37.30

22.05

30

152

4/16 #

213TC

7.5

9.562

7.375

9.000

39.97

24.72

79

201

38.99

23.74

63

185

4/18

213TC

7.5

9.562

7.375

9.000

41.67

26.42

81

203

40.69

25.44

65

187

# Pump type optional with decreased motor power Table 12: Decreased motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

4/3 #

Frame size

143TC

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

F1 [inch]

1.0

6.625

5.250

6.500

22.59

12.83

33

63

21.60

Bare shaft mass

Mass with motor*

F2 [inch]

[lbs]

[lbs]

11.85

17

47

4/6 #

145TC

2.0

6.625

5.250

6.500

26.02

15.39

35

68

25.04

14.41

20

52

4/9 #

182TC

3

7.875

5.875

9.000

29.91

18.78

42

92

28.92

17.80

26

76

4/14 #

184TC

5.0

7.875

5.875

9.000

36.91

23.03

46

115

35.93

22.05

30

99

4/16 #

184TC

5.0

7.875

5.875

9.000

38.60

24.72

79

148

37.62

23.74

63

132

27


3.14

Dimensions DPV 6 B

Table 13: Layout and connections

optional: 1”

optional: 1”

optional: 1”

optional: 1”

Standard DPV(C/S)F Collar flanges in cast iron Norm: ASME B16.1 Size: 1.25” (NPS 5/4) Pressure Class: 250# Option: base plate in AISI304

Optional DPV(S)F Collar flanges in AISI304 Norm: ASME B16.5 Size: 1.25” (NPS 5/4) Pressure Class: 300# Option: base plate in AISI304

Optional DPV(S) 1:Counter flange with female thread in cast stainless steel Norm: ASME B1.20.1 Size: NPT 1.25” Pressure Class: 150# 2:Base plate in AISI304

28


Table 14: Standard motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

F1 [inch]

Bare shaft mass

Mass with motor*

F2 [inch]

[lbs]

[lbs]

6/1

56C

0.5

6.625

5.000

6.500

21.78

12.28

32

51

20.80

11.30

16

35

6/2

56C

1

6.625

5.250

6.500

21.78

12.28

33

63

20.80

11.30

17

47

6/3

143TC

1.5

6.625

5.250

6.500

23.02

13.27

34

64

22.04

23.29

18

48

6/4

145TC

2

6.625

5.250

6.500

24.88

14.25

35

68

23.90

13.27

19

52

6/5

182TC

3

7.875

5.875

9.000

27.23

16.10

36

103

26.25

15.12

20

70

6/6

182TC

3

7.875

5.875

9.000

28.21

17.87

38

88

27.23

16.11

22

72

6/7

184TC

5

7.875

5.875

9.000

31.95

18.07

42

130

30.97

17.10

26

114

6/8

184TC

5

7.875

5.875

9.000

32.93

19.06

43

112

31.95

18.08

27

96

6/9

184TC

5

7.875

5.875

9.000

33.91

20.04

44

113

32.93

19.06

28

97

6/10

184TC

5

7.875

5.875

9.000

34.90

21.02

45

114

33.92

20.04

29

98

6/11 #

213TC

7.5

9.562

5.875

9.000

37.25

22.00

46

167

36.27

21.03

30

152

6/12

213TC

7.5

9.562

5.875

9.000

38.24

22.99

78

200

37.26

22.01

62

184

6/14

213TC

7.5

9.562

7.375

9.000

40.21

24.96

80

202

39.23

23.98

64

186

6/16 #

215TC

10

9.562

7.375

9.000

44.86

29.61

83

205

43.88

28.63

67

189

6/18

215TC

10

9.562

7.375

9.000

46.83

31.57

92

214

45.85

30.60

76

198

# Pump type optional with decreased motor power Decreased motor power Table 15: Decreased motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

F1 [inch]

Bare shaft mass

Mass with motor*

F2 [inch]

[lbs]

[lbs]

6/11 #

184TC

5.0

7.875

5.875

9.000

35.88

22.00

46

115

34.90

21.03

30

99

6/16 #

213TC

7.5

9.562

7.375

9.000

44.86

29.61

83

205

43.88

28.63

67

189

29


3.15

Dimensions DPV 10 B

Table 16: Layout and connections Standard DPV(C/S)F Flanges in cast iron Norm: ASME B16.1 Size: 2” (NPS 2) Pressure Class: 250#

Optional DPV(S)F 1:Collar flanges in AISI304 Norm: ASME B16.5 Size: 2” (NPS 2) Pressure Class: 300# 2:Base plate in AISI304 3:Collar flanges size 6/4”(NPS 6/4”)

30


Table 17: Standard motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare Mass shaft with mass motor*

DPV(S)

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

F1 [inch]

Bare shaft mass

Mass with motor*

F2 [inch]

[lbs]

[lbs]

10/1 #

56C

1

6.625

5.000

6.500

23.04

13.54

56

86

23.04

13.54

41

71

10/2 #

145TC

2

6.625

5.250

6.500

24.42

13.54

57

90

24.42

13.54

42

75

10/3

182TC

3

7.875

5.875

9.000

26.58

15.45

65

115

26.58

15.45

50

100

10/4 #

184TC

5

7.875

5.875

9.000

33.12

16.50

67

136

33.12

16.50

52

121

10/5

184TC

5

7.875

5.875

9.000

31.41

17.54

69

138

31.41

17.54

54

123

10/6 #

213TC

7.5

9.562

7.375

9.000

33.83

18.58

71

193

33.83

18.58

56

168

10/7

213TC

7.5

9.562

7.375

9.000

34.88

19.63

102

224

34.88

19.63

87

209

10/8

213TC

7.5

9.562

7.375

9.000

35.92

20.67

107

229

35.92

20.67

92

214

10/9 #

213TC

10

9.562

7.375

9.000

37.05

21.71

110

232

37.05

21.71

95

217

10/10 # 215TC

10

9.562

7.375

9.000

40.68

25.43

116

238

40.68

25.43

101

223

10/11

7.375

9.000

215TC

10

9.562

41.73

26.48

118

240

41.73

26.48

103

225

10/13 # 215TC

15

12.937 9.625

10.000 45.06

28.56

148

369

45.06

28.56

133

354

10/15

15

12.937 9.625

10.000 47.15

30.65

152

373

47.15

30.65

137

358

215TC

# Pump type optional with decreased motor power Table 18: Decreased motor power: Dimensions and weights are based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare Mass shaft with mass motor*

DPV(S)

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

F1 [inch]

Bare shaft mass

Mass with motor*

F2 [inch]

[lbs]

[lbs]

10/1 #

56C

0.75

6.625

5.250

6.500

23.04

13.54

56

77

23.04

13.54

41

62

10/2 #

143TC

1.5

6.625

5.250

6.500

24.17

13.54

57

87

24.17

13.54

42

72

10/4 #

182TC

3.0

7.875

5.875

9.000

30.37

16.50

67

117

30.37

16.50

52

102

10/6 #

184TC

5.0

7.875

5.875

9.000

32.46

18.58

71

140

32.46

18.58

56

125

10/9 #

213TC

7.5

9.562

7.375

9.000

37.05

21.71

110

232

37.05

21.71

95

217

10/10 # 213TC

7.5

9.562

7.375

9.000

40.68

25.43

116

238

40.68

25.43

101

223

10/13 # 215TC

10

9.562

7.375

9.000

43.81

28.56

148

270

43.81

28.56

133

255

31


3.16

Dimensions DPV 15 C

Table 19: Layout and connections Standard DPV(C/S)F Flanges in cast iron Norm: ASME B16.1 Size: 2” (NPS 2) Pressure Class: 250#

Optional DPV(S)F 1:Collar flanges in AISI304 Norm: ASME B16.5 Size: 2” (NPS 2) Pressure Class: 300# 2:Base plate in AISI304

32


Table 20: Standard motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

F1 [inch]

[lbs]

[lbs]

F1 [inch]

E2 [inch]

P [inch]

F2 [inch]

F2 [inch]

Bare shaft mass

Mass with motor*

[lbs]

[lbs]

15/1

182TC

3

7.875

5.875

9.000

27.01

40.88

64

114

26.61

40.48

51

101

15/2

184TC

5

7.875

5.875

9.000

29.96

43.83

68

137

29.57

43.44

55

124

15/3

213TC

7.5

9.562

7.375

9.000

37.26

52.51

78

200

36.85

52.10

65

187

15/4 #

215TC

10

9.562

7.375

9.000

38.88

54.13

81

203

38.46

53.71

68

190

15/5

215TC

15

12.937 9.625

10.000 44.45

59.70

85

306

44.06

59.31

72

293

15/6

215TC

15

12.937 9.625

10.000 46.06

61.31

87

308

45.67

60.92

74

295

15/7

215TC

15

12.937 9.625

10.000 47.68

62.93

90

311

47.28

62.53

77

298

15/8 #

256TC

20

12.937 9.625

10.000 49.92

66.42

139

360

49.52

66.02

126

-

15/9

256TC

20

12.937 9.625

10.000 51.54

68.04

149

370

51.14

67.64

136

-

15/10

284TSC 25

14.625 13.125 11.250 52.40

71.40

171

542

52.00

71.00

158

-

15/11 # 284TSC 25

14.625 13.125 11.250 54.02

73.02

174

545

53.62

72.62

161

-

# Pump type optional with decreased motor power

, Table 21: Decreased motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

Bare shaft mass

Mass with motor*

DPV(S)

[hp]

E1 [inch]

F1 [inch]

[lbs]

[lbs]

F1 [inch]

E2 [inch]

P [inch]

F2 [inch]

F2 [inch]

Bare shaft mass

Mass with motor*

[lbs]

[lbs]

15/1 #

145TC

2

6.625

5.250

6.500

26.14

36.77

60

93

25.75

36.38

47

80

15/4 #

213TC

7.5

9.562

7.375

9.000

38.88

54.13

81

203

38.46

53.71

68

190

7.375

9.000

44.45

59.70

85

207

44.06

59.31

72

194

10.000 49.29

64.54

132

353

48.89

64.14

119

340

15/5 #

215TC

10

9.562

15/8 #

215TC

15

12.937 9.625

15/10 # 256TC

20

12.937 9.625

10.000 53.15

69.65

153

374

52.75

69.25

140

361

15/11 # 256TC

20

12.937 9.625

10.000 54.76

71.26

156

377

54.36

70.86

143

364

33


3.17

Dimensions DPV 25 B

Table 22: Layout and connections Standard DPV(S)F Norm: ASME B16.1 Size: 2.5” (NPS 2.5) Pressure Class: 250# Option: Pressure class 125#

34


Table 23: Standard motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

25/1

184TC

5

7.875

5.875

9.000

30.81

16.93

110

179

25/2 #

215TC

10

9.562

7.375

9.000

37.89

22.64

125

247

25/3

215TC

15

12.937 9.625

10.000 42.95

25.20

152

373

25/4 #

256TC

20

12.937 9.625

10.000 44.89

28.39

166

387

25/5

256TC

20

12.937 9.625

10.000 47.44

30.94

178

399

25/6 #

284TSC 25

14.625 13.125 11.250 51.76

32.76

181

553

25/7

286TSC 30

16.500 14.125 11.250 53.20

35.31

209

695

# Pump type optional with decreased motor power Table 24: Decreased motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

7.375

9.000

25/2 #

213TC

7.5

9.562

37.89

22.64

125

247

25/4 #

254TC

15

12.937 9.625

10.000 44.89

28.39

166

387

25/6 #

256TC

20

12.937 9.625

10.000 49.26

32.76

181

402

35


3.18

Dimensions DPV 40 B

Table 25: Layout and connections Standard DPV(S)F Norm: ASME B16.1 Size: 3” (NPS 3) Pressure Class: 250#

36


Table 26: Standard motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

40/1-1

213TC

7.5

9.562

7.375

9.000

35.09

19.84

160

282

40/1 #

215TC

10

9.562

7.375

9.000

39.61

22.99

174

349

40/2-2

215TC

15

12.937 9.625

10.000 43.19

26.69

209

430

40/2 #

256TC

20

12.937 9.625

10.000 43.19

26.69

209

430

40/3-2 # 284TSC 25

14.625 13.125 11.250 48.76

29.76

216

588

40/3

284TSC 25

14.625 13.125 11.250 47.98

28.98

217

588

40/4-2 # 286TSC 30

16.500 14.125 11.250 51.05

32.05

224

710

40/4 #

324TSC 40

16.500 14.125 11.250 57.08

32.05

259

745

40/5-2

324TSC 40

16.500 14.125 13.375 60.60

35.47

279

765

40/5

324TSC 40

16.500 14.125 13.375 60.6

35.47

279

765

40/6-2 # 326TSC 50

16.500 14.125 13.375 63.67

38.54

299

894

40/6

326TSC 50

16.500 14.125 13.375 63.67

38.54

299

894

40/7-2 ^ 326TSC 50

16.500 14.125 13.375 66.74

41.61

308

903

40/7 ^

16.500 14.125 13.375 66.74

41.61

350

945

326TSC 50

# Pump type optional with decreased motor power tested as a 50Hz pump (2800 rpm) Table 27: Decreased motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Frame size

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

7.375

9.000

38.24

22.99

174

296

40/1 #

213TC

7.5

9.562

40/2 #

254TC

15

12.937 9.625

10.000 43.19

26.69

209

430

40/3-2 # 256TC

20

12.937 9.625

10.000 46.26

29.76

216

437

40/4-2 # 284TSC 25

14.625 13.125 11.250 51.05

32.05

224

595

40/4 #

286TSC 30

16.500 14.125 13.375 51.05

32.05

259

662

40/6-2 # 324TSC 40

16.500 14.125 13.375 63.67

38.54

299

785

37


3.19

Dimensions DPV 60 B

Table 28: Layout and connections Standard DPV(S)F Norm: ASME B16.1 Size: 4” (NPS 4) Pressure Class: 250#

38


Table 29: Standard motor power: Dimensions and weights are based on typical NEMA motors, not supplied by DP Pumps Model

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

60/1-1 # 215TC

10

9.562

7.375

9.000

38.24

22.99

187

309

60/1

215TC

15

12.937 9.625

10.000 40.12

23.62

214

435

60/2-2 # 256TC

20

12.937 9.625

10.000 43.19

26.69

221

442

60/2

284TSC

25

14.625 13.125 11.250 44.19

25.91

215

586

60/3-2 # 286TSC

30

14.625 13.125 11.250 48.08

28.98

229

715

60/3

324TSC

40

16.500 14.125 13.375 54.46

29.33

269

755

60/4-2

324TSC

40

16.500 14.125 13.375 57.53

32.40

276

762

60/4

326TSC

50

16.500 14.125 13.375 57.53

32.40

276

871

60/5-2 # 364TSC

60

18.250 15.062 13.375 62.44

35.47

302

1071

60/5

60

18.250 15.062 13.375 62.44

35.47

302

1071

Frame size

364TSC

# Pump type optional with decreased motor power Table 30: Decreased motor power: Dimensions and weights based on typical NEMA motors, not supplied by DP Pumps Model

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

E2 [inch]

P [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

60/1-1 # 213TC

7.5

9.562

7.375

9.000

38.24

22.99

187

309

60/2-2 # 254TC

15

12.937 9.625

10.000 43.19

26.69

221

442

60/3-2 # 256TC

20

14.625 13.125 11.250 47.98

28.98

229

600

60/5-2 # 364TSC

50

16.500 14.125 13.375 60.60

35.47

302

897

Frame size

39


3.20

Dimensions DPV 85 B

Table 31: Layout and connections Standard max pressure Class125 DPV(C/S)F Flanges in cast iron Norm: ASME B16.1 Size: 4” (NPS 4) Pressure Class 125#

Optional DPVSF Flanges in AISI304 Norm: ASME B16.5 Size: 4” (NPS 4) Pressure Class 150# Base plate in AISI304

Standard max pressure Class250 DPV(C/S)F Flanges in cast iron Norm: ASME B16.1 Size: 4” (NPS 4) Pressure Class 250#

Optional DPVSF Flanges in AISI304 Norm: ASME B16.5 Size: 4” (NPS 4) Pressure Class 300# Base plate in AISI304

40


Table 32: Dimensions and weights Model

Frame size

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

E2 [inch]

P [inch]

85/1-1

215TC

15

12.937 9.625

10.000 42.00

25.00

229

450

85/1 #

256TC

20

12.937 9.625

10.000 42.63

26.13

234

455

85/2-2

284TSC 25

14.625 13.125 11.250 48.67

29.67

263

634

85/2-1 # 286TSC 30

16.500 14.125 11.250 48.77

29.67

264

750

85/2

286TSC 40

16.500 14.125 11.250 55.08

29.95

303

789

85/3-2 # 326TSC 50

16.500 14.125 13.375 53.36

34.24

325

920

85/3-1 # 326TSC 50

16.500 14.125 13.375 59.36

34.24

326

921

85/3 #

364TSC 60

16.500 14.125 13.375 61.20

34.24

378

1147

85/4-2

364TSC 60

16.500 14.125 13.375 65.40

38.53

399

1168

* Motor dimensions and masses are based on typical NEMA motors, not supplied by DP Pumps

41


3.21

Dimensions DPV 125 B

Table 33: Layout and connections Standard max. pressure Class 125/150 DPV (C/S) F Collar flanges in cast iron Norm: ASME B16.1 Size: 5” (NPS 5) Pressure Class 125/150#

Standard max. pressure Class 250/300 DPVCF Flanges in cast iron Norm: ASME B16.1 Size: 5” (NPS 5) Pressure Class 250/300#

42


Table 34: Dimensions and weights Model

Frame size

Power req.

Motor dimensions*

DPV(C/S)F

[hp]

E1 [inch]

F1 [inch]

E2 [inch]

P [inch]

Bare shaft mass

Mass with motor*

DPVCF

DPV(S)F DPVCF

DPV(S)F

F2 [inch]

[lbs]

[lbs]

[lbs]

[lbs]

125/1

286TSC 30

16.500 14.125 11.250 48.2

29.1

355

399

841

885

125/2-2

324TSC 40

16.500 14.125 13.375 59.34

34.21

386

430

872

916

125/2

364TSC 60

18.250 15.062 13.375 61.18

34.1

397

441

1166

1210

* Motor dimensions and masses are based on typical NEMA motors, not supplied by DP Pumps

43


3.22

Dimensions DPLHS 6

Table 35: Layout and connections DPVLHS Norm: ASME B16.1 Size: 4” (NPS 4) Pressure Class 600# 5/4”(NPS 5/4”)

44


Table 36: Dimensions and weights Model

Frame size

Power req.

Motor dimensions*

DPV(S)F

Bare Mass shaft with mass motor*

[hp]

E1 [inch]

F1 [inch]

F2 [inch]

[lbs]

[lbs]

E2 [inch]

P [inch]

6-100

15

215TC

12.937 9.625

10.000 39.18

22.68

122

343

6-120

15

215TC

12.937 9.625

10.000 40.36

23.86

135

356

6-140

20

256TC

12.937 9.625

10.000 42.17

25.67

153

373

* Motor dimensions and masses are based on typical NEMA motors, not supplied by DP Pumps

45


4

Low NPSH impeller

4.1

General

Low NPSH impeller For the pump type series DPV(S/C)(F) 2, 4, 6, 10 and 15 it is now possible to have a low NPSH solution as option. This solution based on a new designed low NPSH impeller and modified stage casing the NPSH curve of the pump will have much better values throughout its raster. This can prevent cavitation in the pump in case of critical inlet conditions. Cavitation is the process of forming vapour-filled cavities within the liquid in areas where the available pressure has been reduced below a certain critical value. This also happens in case the pressure drops below the vapour pressure of the liquid. When the pressure raises these cavities will implode to become fluid again. These implosions generate pressure waves which are transmitted to the surfaces of the hydraulic pump parts and can damage the material. This phenomenon is called incipient cavitation and is characterized by a metallic noise produced by the hammering on the material.

4.2

46

Benefits of using low NPSH impeller:

"More suitable in critical inlet conditions. Easy adaption to non-optimized application parameters. "The suction lift (Hp) can be less critical (e.g. the frame height of the de-aerating tank in case of boiler feed can be reduced)

Consequences by using a low NPSH impeller:

No change in pump height or connection. Slight adjustments on the performance curve, see curves as published on pages 36 to 40.

4.5

Calculation of NPSHa

Calculation NPSHa > NPSHr + 1.64 Check if cavitation can be expected. Hb + Ho + Hp - HV - Hi > NPSHr + 1.64 Hb = barometric pressure in ft Ho = over pressure (in case of closed tank) in ft Hp = suction lift in ft Hv =- vapour pressure in ft Hl = friction loss in pipe work and accessories in ft NPSHr = net positive suction head of the pump safety factor = 1.64 ft

Risks of cavitation:

Reduced lifetime of the pump due to damaged parts and unbalanced hydraulics. Excessive wear of pump parts or motor bearings. Insufficient cooling and/or lubrication of the mechanical seal and pump bearing.

4.3

4.4

ID3422


Table 37: Calculation NPSHa Atmosferic pressure

+ 33.8 ft

Overpressure in degassing tank

+ ……

Positive height of degassing tank or vessel

+ ……. ft

Vapour pressure of feed water (see table)in degassing tank in case of boiler feed

- ……. ft

Loss of pressure in suction piping and strainer

-

……. ft

Safety factor

-

1.64 ft

NPSHr at duty point (see pumpcurve)

- …….

Minimal positive pressure

x

ft

ft ft

If 'x' is positive there is no cavitation to be expected

Figure 16: Vapour pressure water

Vapour pressure water

If 'x' is negative cavitation can be expected, to avoid this the low NPSH impeller could solve this problem. Otherwise one of the other values can be changed so the outcome will be positive.

47


4.6

Low NPSH grafiek DPV(C/S) 2 B - 60Hz - (3500 rpm)

ID3425

0

1

0.0

0.2

2

[m³/h] [l/s]

0.4

3 0.6

4

0.8

1.0

1.2 250

800 2/22 5 hp

2/20 5/3* hp

700 2/18 3 hp

200

600 2/16 3 hp

2/14 3/2* hp

500 Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

150 2/12 2 hp

400

2/11 2 hp 2/10 2/1.5* hp 2/9 1.5 hp

100

300 2/8 1.5 hp 2/7 1.5/1* hp

[m]

2/6 1 hp

200 [ft] 100

2/5 1/0.75* hp

50

2/4 0.75 hp 2/3 0.5 hp 2/2 0.5 hp

0

0 0

2 [US.gpm]4

0

6

8

10 [IM.gpm]

5

12

14

16

10

18 15

6 NPSHR

[ft]

1 [m]

0

0

60 Eta

%

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

0.2

0

0.1 [hp] [kW] 0.0

0.0 0

ȡ = 1000.0 kg/m³

2

4

6

8

10

12

[US.gpm] Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 17: Grafieken DPV(C/S) 2 B - 60Hz - 2 pole

14

16

18 20170350-B/0

20170350 B

48


4.7

Low NPSH grafiek DPV(C/S) 4 B - 60Hz - (3500 rpm)

ID3425

0

2

0.0

0.5

4

[m³/h] [l/s]

6

1.0

8

1.5

2.0

800 4/18 7.5 hp

700

4/16 7.5/5* hp

200 600 4/14 5 hp

4/12 5 hp

500

150

4/11 5 hp Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

4/10 5/3* hp

400

4/9 5/3* hp 4/8 3 hp

100 300 4/7 3/2* hp 4/6 2 hp

[m]

4/5 2/1.5* hp

200 4/4 1.5 hp

50

[ft] 4/3 1 hp

100 4/2 0.75 hp

0 0

5

0

[US.gpm] 10

0

15

20 [IM.gpm]

10

25

30

35

20

30

15 NPSHR

4 [m]

[ft]

0

0 80 Eta

%

49

0 Leistungsbedarf 0.4 Power Input Puiss. abs. Potenza ass. [hp] Opgenomen vermogen Potencia nec. 0.0

0.2 [kW]

ȡ = 1000.0 kg/m³

5

[US.gpm] 10

0.0 15

20

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 18: Grafieken curve DPV(C/S)4 B - 60Hz - 2 pole

25

30

35 20170351-B/0

20170351 B

0


4.8

Low NPSH grafiek DPV(C/S) 6 B - 60Hz - (3500 rpm)

ID3425

0

2

4

[m³/h]

0

6

1

8

10

2

[l/s]

3

6/18 10/7.5* hp

250

800 6/16 10/7.5* hp

700 200

6/14 7.5 hp

600 6/12 7.5/5* hp

Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

500

6/11 7.5/5* hp

150 6/10 7.5/5* hp 6/9 5 hp

400 6/8 5 hp 6/7 5/3* hp

300

100

6/6 3 hp

[m]

6/5 3/2* hp

200 6/4 2 hp 50

[ft]

6/3 1.5 hp

100 6/2 1 hp 6/1 0.5 hp

0 0

[US.gpm]

10

0

10

0 20

[IM.gpm]

30 20

40 30

50 40

6 NPSHR

1 [m] 0

[ft] 0 80

Eta

%

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.

0.5

50

0 0.3 [kW]

[hp]

0 ȡ = 1000.0 kg/m³

10

[US.gpm]

0.0 20

30

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 19: Grafieken DPV(C/S)6 B - 60Hz - 2 pole

40

50 20170471-B/0

20170471 B

0.0


4.9

Low NPSH grafiek DPV(C/S) 10 B - 60Hz - (3500 rpm)

ID3425

0

5

0

1

10

[m³/h] [l/s]

2

15 3

4 250

800 10/15 15 hp

700 10/13 15/10* hp 200 600 10/11 10 hp 10/10 10 hp

500 Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

150

10/9 10/7.5* hp 10/8 7.5 hp

400 10/7 7.5 hp

100

10/6 5 hp

300 10/5 5 hp

[m] 10/4 5/3* hp

200 10/3 3 hp

50

[ft] 100

10/2 2/1.5* hp 10/1 1/0.75* hp

0 0

0

10 [US.gpm] 20

0

30

40 [IM.gpm]

20

50

60

70

40

60

6 NPSHR

[ft]

[m] 1

0

0

80 Eta

% 0

51

1 0.6 [kW]

[hp]

0

0 0

ȡ = 1000.0 kg/m³

10 [US.gpm] 20

30

40

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 20: Grafieken DPV(C/S) 10 B - 60Hz - 2 pole

50

60

70 20170053-B/0

20170053 B

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.


4.10

Low NPSH grafiek DPV(C/S) 10 B - 60Hz - (1750 rpm)

ID3425

0 0.0

2 0.5

4

[m³/h] [l/s]

6

1.0

8

1.5

2.0

10/11 1.5 hp

140 10/10 1 hp

40 120

10/9 1 hp

10/8 1 hp

100

30

10/7 0.75 hp Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

80

10/6 0.75 hp

10/5 0.75 hp

20 60 10/4 0.75 hp

[m] 10/3 0.75 hp

40 10

[ft] 10/2 0.75 hp 20 10/1 0.75 hp

0

0 0

5 [US.gpm] 10

0

15 10

20 [IM.gpm]

25

30

35

20

30

1.5 NPSHR

0.4

[ft]

[m] 0

0 80 Eta

52

% 0 0.1 0.05

[hp]

[kW] 0.0

0.0 0

ȡ = 1000.0 kg/m³

5 [US.gpm] 10

15

20

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 21: Grafieken DPV(C/S) 10 B - 60Hz - 4 pole

25

30

35 20170054-B/0

20170054 B

Leistungsbedarf Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.


4.11

Low NPSH grafiek DPV(C/S) 15 C - 60Hz - (3500 rpm)

ID3425

0

10

0

2

20

[m³/h] 4

[l/s]

6

15/11 1 25 2 hp

800

15/10 25 hp

700 15/9 20 hp

600

500 Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

200

15/8 20 hp

15/7 20 hp

150 15/6 15 hp

400 15/5 15 hp

100 300 15/4 10 hp [m] 15/3 7.5 hp

200 [ft]

50

15/2 5 hp

100 15/1 3 hp

0 0

20

0

0

[US.gpm] 40 20

[IM.gpm]

60 40

80 60

100 80

120 100

10 NPSHR

3 [m]

[ft]

0

0 80 Eta

%

53

0 1.5

2

[kW]

[hp] 0 0

ȡ = 1000.0 kg/m³

20

[US.gpm] 40

0 60

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 22: Grafieken DPV(C/S) 15 C - 60Hz - 2 pole

80

100

120 20210135-A/0

20210135 A

Leistungsbedarf* Power Input Puiss. abs. Potenza ass. Opgenomen vermogen Potencia nec.


4.12

Low NPSH grafiek DPV(C/S) 15 C - 60Hz - (1750 rpm)

ID3425

0

5

0

1

10

[m³/h] 2

[l/s]

3

4

200 15/11 3 hp

180

60

15/10 3 hp

15/9 3 hp

160 15/8 3 hp

140 40

15/7 2 hp

120 Förderhöhe TDH Hauteur Prevalenza Opvoerhoogte Altura

15/6 2 hp

100

[m] 15/5 1.5 hp

80 15/4 1.5 hp

20 60

15/3 1 hp

40 15/2 0.75 hp [ft] 20 15/1 0.33 hp

0 0

10

0

0

[US.gpm] 20 10

[IM.gpm]

30 20

40 30

50 40

60 50

3 NPSHR

0.5 [m] 0

[ft] 0 80

Eta

54

% 0

Leistungsbedarf* 0.3 Power Input Puiss. abs. Potenza ass. [hp] Opgenomen vermogen Potencia nec. 0.0

0.2 [kW]

ȡ = 1000.0 kg/m³

10

[US.gpm] 20

0.0 30

Fördermenge/Flow/Débit/Portata/Capaciteit/Caudal

Figure 23: Grafieken DPV(C/S) 15 C - 60Hz - 4 pole

40

50

60 20210136/0

20210136

0


5

Seals

5.1

Mechanical seal option specifications

Cartridge

Easy Access

Fixed

Max. pressure [psi]

Temperature range shaft seal[oF]

Material pump elastomer

Material shaft seal

Seal code

Shaft seal Type

Material mechanical seal

Table 38: Seal code

RMG-G606 Q1 B E GG

13 SiC / Ca / EPDM

EPDM WRAS / ACS -4 upto +212

360

  

RMG-G606 Q1 B V GG

14 SiC / Ca / FPM

FPM

360

  

-4 upto +248

RMG-G606 U3 U3 X4 GG

15 TuC / TuC / HNBR

HNBR

-4 upto +248 (284)

360 (232)

  

RMG-G606 U3 U3 V GG

16 TuC / TuC / FPM

FPM

-4 upto +248 (284)

360 (232)

  

RMG-G606 U3 B E GG H7N

Q1 A E GG

18 TuC / Ca / EPDM

EPDM 559236

-4 upto +248 (284)

360 (232)

  

20 SiC / Ca / EPDM

EPDM 559236

-4 upto +248 (284)

580 (360)

H7N

Q1 A V GG

21 SiC / Ca / FPM

FPM

-4 upto +248 (284)

580 (360)

H7N

Q1 A X4 GG

22 SiC / Ca / HNBR

HNBR

-4 upto +248 (284)

580 (360)

RMG-G606 Q1 B E GG

23 SiC / Ca / EPDM

EPDM

-4 upto +212

360

  

RMG-G606 Q1 B E GG

33 SiC / Ca / EPDM

EPDM NSF

-4 upto +212

360

  

RMG-G6

eCa eSiC E GG 35 eCa / eSiC / EPDM EPDM WRAS / ACS -4 upto +248

360

MG-G6

eCa eSiC V GG 36 eCa / eSiC / FPM

360

RMG-G606 U3 A V GG 4MC Q1 Q1 E GG 4MC Q1 B E GG

FPM

-4 upto +248

37 TuC / Ca / FPM

FPM

-4 upto +248 (284)

360 (232)

40 SiC / SiC/ EPDM

EPDM 559236

-4 upto +248 (284)

360 (232)

41 SiC / Ca / EPDM

EPDM 559236

-4 upto +248 (284)

360 (232)

4MC

Q1 Q1 V GG

42 SiC / SiC/ FPM

FPM

-4 upto +248 (284)

360 (232)

4MC

Q1 B V GG

43 SiC / Ca / FPM

FPM

-4 upto +248 (284)

360 (232)

ATTENTION Seal dimensions according to EN24960

5.1.1

Seal material description

Seal part Face material

synthetic carbon carbides

Elastomer

Code

Description

A

Carbon graphite antimony impregnated

B

Carbon graphite resin impregnated

Q1

SiC, silicon carbide, sintered

U3

Tungsten carbide, NiCrMo-binder

E

Ethylene propylene rubber (EPDM)

V

Fluorcarbon rubber (FPM)

X4

Hydrogenated Nitrile-rubber (HNBR)

Spring material

G

CrNiMo steel (1.4571)

Construction material

G

CrNiMo steel (1.4571)

55


6

Motors

6.1

General

For the NEMA flanged bare shaft pumps specific C-faced NEMA motors can be mounted. For these motors the following technical specification regarding the bearings needs to be considered. Fixed driven-end re-enforced bearing according the following table

56

Rated power

Frame size

DE bearing NDE bearing

0.5

56C

6203 2Z-C3 supplier standard

0.75

56C

6203 2Z-C3 supplier standard

1

143TC

6204 2Z-C3 supplier standard

1.5

143TC

6204 2Z-C3 supplier standard

2

145TC

6305 2Z-C3 supplier standard

3

182TC

6305 2Z-C3 supplier standard

5

184TC

6306 2Z-C3 supplier standard

7.5

213TC

7309

supplier standard

10

215TC

7309

supplier standard

15

215TC

7309

supplier standard

20

256TC

7311

supplier standard

25

284TSC

7311

supplier standard

30

286TSC

7312

supplier standard

40

324TSC

7312

supplier standard

50

326TSC

7313

supplier standard

60

364TSC

6312

supplier standard


7

Materials

7.1

Parts overview

7.1.1

Part list

part description

ASTM/ANSI code

material code

Wetted part

VC

Pump casing

ASTM Class 35

JL1040

X

AISI 304

1.4308

X X

AISI 316

1.4408

(Loose plate) flange

ASTM Class 25

JL1030

AISI 304

1.4308

Pump shroud

AISI 304

1.4301

X

AISI 316L

1.4404

X

AISI 304

1.4301

X

AISI 316L

1.4404

X

AISI 304

1.4301

X

AISI 316L

1.4404

X

AISI 431

1.4057

X

AISI 329

1.4460

X

AISI 304

1.4301

X X

Stage Casing Cover Shaft Impeller

V

VS

  

    

AISI 316L

1.4404

Motor stool

ASTM Class 35

JL1040

Pump sealing elastomers

EPDM

X

EPDM WRAS/ACS

X

FPM

X

EPDM 559236

X

HNBR

X

PPS450CA30 DPV125

X

Seal cover Spacer sleeve

AISI 304

1.4308

X

AISI 316

1.4408

X

AISI 304

1.4301

X

AISI 316

1.4404

X

Bearing sleeve

Tungsten Carbide

X

Bearing

Aluminium Oxide

X

Taper piece

ASTM Class 35

JL1040

Coupling from 7.5hp

ASTM Class 25

JS1030

JS1040

Coupling up to 5hp

Aluminium

Base plate

ASTM Class 35

Base plate

AISI 304

1.4308

Screwed plugs (vent) and drain

AISI 304

1.4301 (A2)

X X

AISI 316

1.4404 (A4)

Tie bolt

AISI 431

1.4057

Lock nut

AISI 304

1.4301

X

 

57


part description

ASTM/ANSI code

material code

Wetted part

VC

V

AISI 316

1.4404

X

Safety device Nord-lock

AISI 316L

1.4404

Circlip

AISI 316Ti

Wave spring DPV(C/S) 2-15 B

AISI 304 AISI 316

VS

X

1.4571

X

1.4300

X

1.4401

X

 Standard  Option

7.1.2

Materials conversion

Material

ASTM / AISI1

Description

Code and material nr.

Standard

JL 1040

A48:40B

Cast iron

GJL-250

EN 1561

Cast iron

GJS-400

EN 1563

1.4057

A276:431

Chromium-nickel steel

X17CrNi16-2--QT800

EN 10088-3

14300

A276:302

1.4301

A276:304

JS1030

X12CrNi 18-8

EN 10088

X5CrNi 18-10

EN 10088

1.4305

A276:303

Chromium-nickel steel

X8CrNiS 18-9

EN 10088

1.4308

A743:CF8

Chromium-nickel cast steel

GX5CrNi 19-10

EN 10283

1.4401

A276:316

Chromium-nickel-molybdenum steel

X5CrNiMo 17-12-2

EN 10088

1.4404

A276:316L

Chromium-nickel-molybdenum steel

X2CrNiMo 17-12-2

EN 10088

GX5CrNiMo 19-11-2

EN 10213

1.4408 1.4460 1.4571 1.

58

Chromium-nickel steel Chromium-nickel steel

A743CF8M --:329 A276:316Ti

Chromium-nickel-molybdenum cast steel Chromium-nickel-molybdenum steel Chromium-nickel-molybdenum steel

Note: The indication of the material designations to ASTM / AISI is not binding

X3CrNiMoN 27 5 2

EN 10088

X6CrNiMoTi 17-12-2

EN 10088


8

Medium handled

8.1

Medium handled

Media description

Media group

Chemical for- Cons. mula max. [%]

PH Temp max. max. {C]

Model Material shaft seal

Material pump

rotor

stator elas- elastomer tomer

Acetic acid

Acid

(CH3COOH

5

20

V

SiC

Ca

EPDM EPDM

Acetic anhydride

Weak acid derivative

(CH3CO)2O

20

20

V

SiC

Ca

EPDM EPDM

Acetone

Ketone

(CH3)2CO

VC

SiC

Ca

EPDM EPDM

CH3COCl

Acetyl chloride Alcaline (bottle rinse)

Rinsing

Alcohol (Ethanol)

Hydrocarbon

40 2

C2H5OH

100

VS

SiC

Ca

EPDM EPDM

< 9.5 40

V

TuC

TuC

HNBR HNBR

60

V

SiC

Ca

EPDM EPDM

Alum (potassium Salt aluminium sulphate)

MI MIII (SO4)2 3

80

VS

SiC

Ca

FPM

Aluminium chloride

Halide

AlCl3

5

50

VS

SiC

Ca

EPDM EPDM

Aluminium chloride

Halide

AlCl3

25

20

VS

SiC

Ca

EPDM EPDM

Aluminium sulphate

Salt

Al2(SO4)3

Aluminium sulphate

Salt

Al2(SO4)3

Ammonia

Strong base

FPM

20

V

SiC

Ca

EPDM EPDM

5

Boiling

VS

SiC

Ca

EPDM EPDM

VC

SiC

Ca

EPDM EPDM

Ammonium bicarbo- Salt nate

(NH4)HCO3

10

40

V

SiC

Ca

EPDM EPDM

Ammonium sulphate Salt

(NH4)2SO4

20

60

V

SiC

Ca

EPDM EPDM

NH3

Antifreeze (glycol base, salt-free)

Alcohol

45

110

V

SiC

Ca

EPDM EPDM

Beer (not lathery / under pressure)

Alcohol

100

15

V

SiC

Ca

EPDM EPDM

Benzene

Hydrocarbon solvent

C6H6

VS

SiC

Ca

FPM

Boric acid

Acid

H3BO3

V

SiC

Ca

EPDM EPDM

Buttermilk

Dairy product

fats + water

V

SiC

Ca

EPDM EPDM

Butyl alcohol (butanol)

Hydrocarbon

CH3(CH2)3OH

SiC

Ca

EPDM EPDM

100

60

FPM

Calcium acetate

Salt

C4H6O4Ca

10

60

VS

SiC

Ca

EPDM EPDM

Calcium nitrate (non-acidic)

Salt

Ca(No3)2

10

60

VS

TuC

TuC

FPM

Cider (apple cider)

Alcohol

H2O + sucrose + alcohol

100

40

V

SiC

Ca

EPDM EPDM

Citric acid

Acid

C3H4(OH)(C OOH)3

5

20

VS

SiC

Ca

FPM

CuSO4-5H2O

5

80

V

TuC

TuC

HNBR HNBR

100

100

VS

SiC

Ca

FPM

FPM

V

SiC

Ca

FPM

FPM

Copper sulphate

Salt

Corn oil

Vegetable oil

Diesel oil

Hydrocarbons

FPM

FPM

59


Media description

Diethylene glycol (salt-free)

Alcohol

Chemical for- Cons. mula max. [%]

PH Temp max. max. {C]

Model Material shaft seal

Material pump

rotor

stator elas- elastomer tomer

C4H10O3

100

100

VC

SiC

Ca

EPDM EPDM

Ethanol (alcohol)

Hydrocarbon

C2H5OH

100

60

V

SiC

Ca

EPDM EPDM

Ethylene glycol (salt-free)

Alcohol

(CH2OH)2

100

100

V

SiC

Ca

EPDM EPDM

Ferric-III-chloride

Salt

FeCl3

5

80

V

TuC

TuC

FPM

FPM

80

VS

SiC

Ca

FPM

FPM

C3H8O3

40

80

V

SiC

Ca

EPDM EPDM

Fuel oil (light)

Hydrocarbon

Glycerin (glycerol)

Alcohol

Kerosene

Hydrocarbon

100

80

V

SiC

Ca

FPM

FPM

Linseed oil

Vegetable oil

100

60

V

SiC

Ca

FPM

FPM

Linseed oil + 3% sul- Vegetable oil phur acid

100

60

V

SiC

Ca

FPM

FPM

10

80

V

SiC

Ca

FPM

FPM FPM

Magnesium sulphate

60

Media group

Salt

MgSO4

Malic acid

Acid

C4H2O3

V

SiC

Ca

FPM

Methanol

Alcohol

CH3OH

V

SiC

Ca

EPDM EPDM

Methyl glycol (propylene glycol)

Alcohol

C3H6(OH)2

VC

SiC

Ca

EPDM EPDM

Milk

Dairy product

fats + water

V

SiC

Ca

EPDM EPDM

Olive oil

Vegetable oil

VC

SiC

Ca

FPM

100

20

FPM

Oxalic acid

Acid

H2C2O4

5

20

V

SiC

Ca

EPDM EPDM

Oxalic acid

Acid

H2C2O4

5

Boiling

VS

SiC

Ca

FPM

Oxalic acid

Acid

H2C2O4

10

60

V

SiC

Ca

EPDM EPDM

Paraffins

Hydrocarbon

V

SiC

Ca

FPM

FPM

Peanut oil

Vegetable oil

Petroleum

Hydrocarbon

Hydrocarbon

FPM

100

90

V

SiC

Ca

FPM

FPM

100

80

V

SiC

Ca

FPM

FPM

Potassium chlorate

Salt

KClO3

VS

TuC

TuC

HNBR HNBR

Potassium chloride

Salt

KCl

V

SiC

Ca

EPDM EPDM

Potassium hydroxide

Salt

KOH

5

40

VS

SiC

Ca

EPDM EPDM

Potassium nitrate

Salt

KNO3

5

30

VS

TuC

TuC

HNBR HNBR

Potassium sulphate

Salt

K2SO4

3

20

VS

SiC

Ca

FPM

FPM

Rape-seed oil

Vegetable oil

mixture

100

VS

SiC

Ca

FPM

FPM

Sodium carbonate

Salt

Na2CO3

6

60

V

SiC

Ca

EPDM EPDM

Sodium chloride

See sea water

NaCl

Sodium hydroxide (soda lye)

Salt

NaOH

5

50

VS

TuC

TuC

HNBR HNBR

Sodium nitrate (non acidic)

Salt

NaNO3

10

60

V

SiC

Ca

EPDM EPDM

Sodium phosphate

Salt

Na3PO4

V

SiC

Ca

EPDM EPDM

Sodium sulphate (non acicdic)

Salt

Na2SO4

5

V

SiC

Ca

EPDM EPDM

Soybean oil

Vegetable oil

100

100

V

SiC

Ca

FPM

Spirits

Alcohol

H2O + sucrose + alcohol

40

60

V

SiC

Ca

EPDM EPDM

Sulphuric acid

Acid

H2SO4

5

30

VS

TuC

TuC

FPM

60

FPM

FPM


Media description

Media group

Chemical for- Cons. mula max. [%]

PH Temp max. max. {C]

Model Material shaft seal

Material pump

rotor

stator elas- elastomer tomer

Tannic acid

Acid

C76H52O46

20

80

V

SiC

Ca

FPM

FPM

Tartaric acid

Acid

C4H6O6

8

40

VS

SiC

Ca

FPM

FPM

Vinegar (wine vinegar)

Acid

CH3COOH

10

60

VS

SiC

Ca

EPDM EPDM

Water, untreated / suspended solids <20 ppm

Water

H2O + ...

100

60

VC

TuC

Ca

EPDM EPDM

Water, boiler feed water (conform. Vd TÜV 1466

Water

H2O + ...

100

120

VC

TuC

Ca

EPDM EPDM E425

Water, brackish

Sea water

H2O + ...

100

7

5

V

TuC

TuC

FPM

FPM

Water, brackish

Sea water

H2O + ...

100

7

10

V

TuC

TuC

FPM

FPM

Water, brackish

Sea water

H2O + ...

100

7

15

VS

TuC

TuC

FPM

FPM

Water, brackish

Sea water

H2O + ...

100

7

20

VS

TuC

TuC

FPM

FPM

Water, brackish

Sea water

H2O + ...

100

7

25

VS

TuC

TuC

FPM

FPM

Water, coast water

Sea water

H2O + ...

100

7

5

VS

TuC

TuC

FPM

FPM

Water, coast water

Sea water

H2O + ...

100

7

10

VS

TuC

TuC

FPM

FPM

Water, coast water

Sea water

H2O + ...

7

15

VS

TuC

TuC

FPM

FPM

Water, condensate (conform Vd TÜV 1466)

Water

H2O + ...

100

VS

TuC

Ca

EPDM EPDM

Water, cooling water Water

H2O + ...

100

VS

TuC

TuC

HNBR HNBR

Water, de-carbonised (softened)

Water

H2O + ...

120

V

TuC

TuC

HNBR HNBR

Water, de-ionised

Water

H2O + ...

120

V

SiC

Ca

EPDM EPDM

Water, distilled

Water

H2O + ...

V

SiC

Ca

EPDM EPDM

Water, fire fighting

Water

H2O + ...

100

60

VC

TuC

TuC

HNBR HNBR

Water, harbour

Sea water

H2O + ...

100

7

5

VS

TuC

TuC

FPM

FPM

Water, harbour

Sea water

7

FPM

100

100

H2O + ...

100

10

VS

TuC

TuC

FPM

Water, heating (con- Water form Vd TÜV 1466)

H2O + ...

100

120

VC

SiC

Ca

EPDM EPDM

Water, (conform VDI 2035)

Water

H2O + ...

100

100

VC

TuC

Ca

EPDM EPDM

Water, oil water mixture

Water

5

80

V

SiC

Ca

FPM

FPM

Water, ordinary sea water

Sea water

H2O + ...

100

7

5

V

TuC

TuC

FPM

FPM

Water, ordinary sea water

Sea water

H2O + ...

100

7

10

VS

TuC

TuC

FPM

FPM

Water, ordinary sea water

Sea water

H2O + ...

100

7

15

VS

TuC

TuC

FPM

FPM

Water, ordinary sea water

Sea water

H2O + ...

100

7

20

VS

TuC

TuC

FPM

FPM

61


Media description

62

Media group

Chemical for- Cons. mula max. [%]

Water (Ozon 0.5 mg/l)

Water

H2O + ...

Water, pure (chemically neutral)

Water

H2O + ...

Water, rinsing

Water

Water, swimmingpool (chlorine 0.8 mg/l)

Water

Water, tap (drinking water)

Water

H2O + ...

PH Temp max. max. {C]

Model Material shaft seal

Material pump

rotor

stator elas- elastomer tomer

25

V

SiC

Ca

EPDM EPDM

60

V

SiC

Ca

EPDM EPDM

H2O + ...

70

VS

TuC

TuC

FPM

FPM

H2O + ...

25

VS

SiC

Ca

FPM

FPM

60

V

SiC

Ca

EPDM EPDM WRc/ ACS

100

100


63


dp pumps P.O. Box 28 2400 AA Alphen aan den Rijn The Netherlands t +31 172 48 83 88

dp@dp-pumps.com www.dp-pumps.com 07/2021 97004480 H Subject to modifications. Digital alteration, publication or distribution of the content of this document without prior notice is strictly prohibited. Permission for use, copying and distribution of this document as published by DP-Pumps is granted on the condition that no part of the document is used for information or commercial purposes outside of the DP-Pumps organisation or one of its recognised dealerships.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.