Residence Zulu_Zinkwazi beach Durban_Working Drawings_Part 2

Page 1

GENERAL NOTES: •

All dimensions and levels to be verified on site, prior to the commencement of setting out ,working drawings or conctruction drawings are not to be scaled. Figured dimensions only are to be used. Any discrepancies, errors and omissions are to be reported to the Architect immeditely before commencing with any work. All shop drawings are to be submitted for designer's approval prior to manufacturign and installation. All work is to be in strict accordancen with the by-laws and regulations of the local authority. Where required, architects drawings are to be read in conjunction with engineers drawings. Copyright and right of reproduction of this drawing or any part thereof is reserved and remains with the architect. All structural concrete,brick work ,steel works and timber works are to the engineers specification & details. All timber to be grade 6/7 - section 1&2 All roof timber trusses to be as per the National building Regulations. Glazing to be as per the National building Regulations. Addional requirements recommended by supplier to be discussed with Archiect & Cient.

• •

WALL LEGEND:

NEW BRICK WALLS

• •

NEW CONCRETE WALLS - CLASS 1

NEW DRYWALLS

EXISTING WALLS

• • •

Please note: Plastering All external plaster to contain Perlite as per the manufacturer’s specification. All internal plaster to be two coat plaster finished perfectly smooth and hard, with steel reinforced corners.

Roof fascia board as per specialist specifications as per manufacturer.

Landscaping as per specialist

15°

Dpc

FILL

FILL

-255

Surface bed 85mm thick concrete surface bed with Ref 193 steel mesh on damproof course layer on sand.

D 1

Timber slats as per specialist -425

FILL

Dpc

Dpc

FILL

New Foundations to Engineers detail

NGL

1990

1960

3995

4590

170

600

FILL

Dpc

Dpc

50mmØ waste pipes COVERED CAR PARKING to be laid in slab as U/s slab @ 2875mm afsl per specialist Non Slip Tiles 330x330mm concrete column to Engineers detail

New Steel sheet surround panel as per specialist

Existing 110mmØ outlet pipe to soak pit to remain unaffected

2520 510

EXTERNAL POOL DECK BEHIND

SEPTIC TANK BELOW (To remain unaffected) Additional fittings & requirements as per specialist

2550

Galvanized 3mm aluminium panels on 50x50mm SHS sub-frame. waterproofing by specialsit Raised platform to Engineers detail & specifications

NGL

SOAK PIT Below to remain unaffected

AREA SCHEDULE:

Wood fire place to specialist detail and interiors position

0

Planter-no concrete Waterproofing as per specialist

FIRST STOREY

330x510mm concrete beam to Engineers detail New raised sculpture podium to Engineers detail

New 170mm concrete slab to Engineers detail Planter- concrete below Landscaping as per specialist Waterproofing as per specialist

-510

Existing 110mmØ uPVC soil pipe min. 1:60 (max. 1:10) to remain unaffected (To connect to Septic Tank as per specialist detail & specifications)

Dpc

Timber decking as per specialist

Precast Rectangular Column with Multi Layer Corbels to Engineers detail

Surface bed Dpc FILL 120mm thick concrete surface bed with Ref 193 steel mesh on damproof course layer on sand.

New Foundations to Engineers detail

228 600

170 60

510

U/s slab plastered /rhinolited and painted

1m high SANS approved glass balustrade (by specialist) Bulkhead and ceiling as per specialist

3014 Fire wood storage unit to specialist detail and interiors position 2750 2665 228 350

2380

2350

2950

3680

2665

New 340mm concrete slab to Engineers detail

NGL

Surface bed 120mm thick concrete surface bed with Ref 193 steel mesh on 50mm thick high density polystyrene on damproof course layer on sand

3265

2240

W 9

5270

Louvre fixed screen on subframe to specialist detail

2670

DOUBLE GARAGE

2750

330x510mm concrete beam to Engineers detail

New Concrete lintels @ 2125mm afsl

U/s slab @ 2835mm afsl Tiles

2750

Open Timber Decking

Raised platform to Engineers detail & specifications Wood fire place to specialist detail and interiors position

2440

330x510mm concrete beam to Engineers detail

Dpc

2750

D 5

2607

510

U/s slab plastered /rhinolited and painted

510

New 340mm concrete slab to Engineers detail

Ottoman by specialist

Aircon by Specialist 7770

7690

New vanity as per specialit

3530

4510 1030 New vanity as per specialit

U/s Ceiling to Rafter Tiles

WALL PLATE

New Steel sheet surround panel as per specialist

BALCONY 1

2440

2670

2670 330x330mm concrete column to Engineers detail

U/s Ceiling to Rafter Tiles 2750

5311

Vertical Dpc

-425

Surface bed to Engineers detail slope to be confirmed on site.

D 1

Ottoman by specialist

BEDROOM 1

7260

LOUVRE SCREEN 1

2240

New Concrete lintels @ 2125mm afsl

New whb

2670

510

510

170

Dpc

New whb

BATHROOM 1

ROOF LEVEL

Concrete roof (47m²) 170mm concrete roof to Engineers details at 2% fall towards rainwater outlets. Waterproofing by specialist

Vertical Dpc

0

New B.I.C by specialist

Lighting fixtures as per specialist

5311

W 10.

Revision Description

Roof fascia board as per specialist specifications as per manufacturer.

New Concrete lintels @ 2950mm afsl

Vertical Dpc

GROUND STOREY

220mm brick wall to Engineers detail

New B.I.C by specialist

U/s Ceiling to Rafter Tiles

Dpc

2750

Landscaping as per specialist

85mm Exposed aggregate surfacebed ramp

2840

Self Closing Motorised Sliding Gate as per specialist

New steel sheet window surround to specialist detail

Timber slats as per specialist

BATHROOM 2

2750

220mm brick walls to Engineers detail

Revision Revision Number Date

150x150 CFLC steel gutters to Engineers detail & specifications

W 25

6277

New steel sheet window surround to specialist detail

Timber slats as per specialist

Aircon by Specialist

2580

Timber slats as per specialist Open Exposed aggregate surfacebeds

980

BEDROOM 2

U/s Ceiling to Rafter Tiles

330x510mm concrete beam to Engineers detail New 170mm concrete slab to Engineers detail

DRIVEWAY

Lighting fixtures as per specialist

2350

600

3530

1000

4103

Ceiling to underside of rafters 150mm Mineral fibre insulation between rafters

New Concrete lintels @ 2950mm afsl

2750

New Steel sheet surround panel as per specialist

2550

W 9.

Ceiling to underside of rafters 150mm 330mm brick walls Mineral fibre insulation between rafters to Engineers detail

7690

Polystyrene infill below plastic modular panter boxes

1350

4680

Green square modular plastic tray planter boxes as per specialist. Irrigation system required to be confirmed by specialist

7690

Planter- concrete below Landscaping as per specialist Waterproofing as per specialist

FIRST STOREY

Dpc

590

New steel sheet window surround to specialist detail

5270

6277

580

220mm brick walls to Engineers detail

WALL PLATE

W 25

980

Roof fascia board as per specialist specifications as per manufacturer.

980

ROOF LEVEL 7260

Revision Schedule

Concrete Roof Tiles (23m2) Concrete Roof Tiles as per specialist @ 20° & 45°.On 75x50mm purlins to Engineers detail. on 50x150mm timber rafters to Engineers specifications. Waterproofing by specialist

New Foundations to Engineers detail

Vertical Dpc

Concrete Roof Tiles (23m2) Concrete Roof Tiles as per specialist @ 20° & 45°.On 75x50mm purlins to Engineers detail. on 50x150mm timber rafters to Engineers specifications. Waterproofing by specialist

STAMPS:

NGL

GROUND STOREY 0

NGL

EXISTING NEW WORK TOTALS: EXISTING NEW WORK TOTALS:

BASEMENT

G.FLOOR

1st FLOOR

2nd FLOOR

3rd FLOOR 4th FLOOR

COVERAGE F.A.R. TOTAL AREAS:

New Foundations to Engineers detail

Galvanized 3mm aluminium panels on 50x50mm SHS sub-frame. waterproofing by specialsit

SECTION A-A SCALE 1 : 50

Concrete Roof Tiles (53m2) Concrete Roof Tiles as per specialist @ 20° & 45°.On 75x50mm purlins to Engineers detail. on 50x150mm timber rafters to Engineers specifications. Waterproofing by specialist

New 170mm concrete slab to Engineers detail

New Foundations to Engineers detail

Dpc

SCALE 1 : 50

1990

1990

4510

330x510mm concrete beam to Engineers detail

2860

Green square modular plastic tray planter boxes as per specialist. Irrigation system required to be confirmed by specialist Line of 170mm concrete slab behind to Engineers detail

2750 2410

510

2750

50x150mm timber rafters to Engineers specifications.Waterproofing by specialsit

New 340mm concrete slab to Engineers detail U/s slab plastered /rhinolited and painted

330x510mm concrete beam to Engineers detail

Timber decking as per specialist specifications as per manufacturer. Precast Rectangular Column with Multi Layer Corbels to Engineers detail

0

NGL

260

260

Open Timber Decking -255

2240 1510

EXTERNAL POOL DECK

2240

2240

2500

New Concrete lintels @ 2125mm afsl

LOT 194,104 Glen drive,Zinkwazi Beach,Kwadukuza Municipality

Planter- concrete below Waterproofing as per specialist

D 7

170

New Steel sheet surround panel as per specialist 510

930 170 340

Rainwater drainage chain as per specialist

7520

340

260

7520

2520

New Concrete lintels @ 2125mm afsl

Vertical creepers as per landscaping specialist

330mm retaining wall to Engineers detail Existing landscaping behind

Bulkhead and ceiling as per specialist

Surface bed Dpc FILL Dpc 120mm thick concrete surface bed with Ref 193 steel mesh on 50mm thick high density polystyrene on New Foundations damproof course layer on sand to Engineers detail 1m high SANS approved glass balustrade (by specialist) Existing 110mmØ uPVC soil pipe min. 1:60 (max. 1:10) to remain unaffected (To connect to Septic Tank as per specialist detail & specifications)

SECTION B-B

2750

2410

11

12

Dpc 10 U/s slab @ 2720mm afsl 9 Tiles 8 330x330mm Aircon by Specialist 7 concrete column W 6 to Engineers detail 5 3 New Floating concrete 4 3 staircase to specialist detail 2 Treads: 300mm -170 1 Risers: 170mm

Dpc NGL

New Foundations to Engineers detail

2210 510

220X400mm concrete beam to Engineers detail

2720

2720 Landscaping as per specialist

-170

18 17 16 15 14 13

2410

5440

W 2

Existing wc behind

Surface bed Dpc 170mm thick concrete surface bed with Ref 193 steel mesh on New Foundations damproof course layer on sand. New Foundations to Engineers detail to Engineers detail

400

170

Dpc

2720

U/s Ceiling to Rafter W Tiles W 21 3675 22 Aircon by Specialist

7430

5440

2320

D 10

Dpc 304x76mm timber beam to Engineers detail

150x150 CFLC steel gutters to Engineers detail & specifications

Dpc

85

-680

Waterproofing as per specialist

-170

23°

Roof fascia board as per specialist specifications as per manufacturer.

20°

PASSAGE 1

Vertical Dpc

220mmbrick wall to Engineers detail

Landscaping as per specialist

Stainless steel water spillover by specialist

Water feature - 6m 2

W 23

NEW STAIRCASE LOBBY

Vertical Dpc

Vertical Dpc

NGL

Vertical Dpc

NGL

0

Galvanized 50x50mm SHS panels. waterproofing by specialsit

Dpc

Vertical Dpc

0

2720

Vertical Dpc

2240

Existing wall to remain unaffected

680

330x330mm concrete column to Engineers detail

1590

Landscaping as per specialist

Dpc 4333

2950

New opening in existing wall to Engineers detail Lintel height @ 2720mm.Existing window to be removed 2550

960

Vertical Dpc

GROUND STOREY

100

Existing RWDP to be cut back. Rainwater to discharge onto 170mm concrete slab to Engineers detail

New 170mm concrete slab to Engineers detail

Timber slated fence by specialist 2.0m high Boundary wall from NGL.220mm brick wall & clearvu fence above to Engineers details & specifications.

2550

2720 2750

1590

Existing wall to be platered & painted

Flashing/ waterproofing by specialist

Planter-concrete below Waterproofing as per specialist

5950

330x510mm concrete beam to Engineers detail

2550

3049

510

FIRST STOREY

New RWDP as per specialist specifications as per manufacturer. 2520

Green square modular plastic tray planter boxes as per specialist. Irrigation system required to be confirmed by specialist

20°

1960 5301

Roof fascia board as per specialist specifications as per manufacturer. Planter-no concrete Waterproofing as per specialist

°

5270

45

Existing rainwater gutters to remain unaffected

WALL PLATE

45°

Concrete Roof Tiles (73m2) Concrete Roof Tiles as per specialist @ 20° & 45°.On 75x50mm purlins to Engineers detail. on 50x150mm timber rafters to Engineers specifications. Waterproofing by specialist

45°

Concrete Roof Tiles (16m2) Concrete Roof Tiles as per specialist @ 20° & 45°.On 75x50mm purlins to Engineers detail. on 50x150mm timber rafters to Engineers specifications. Waterproofing by specialist

°

7260

Ceiling to underside of rafters 150mm Mineral fibre insulation between rafters

45

ROOF LEVEL

New Steel sheet surround panel as per specialist Planter-concrete below Waterproofing as per specialist

New Proposed Residence for (ANDILE ZULU)

20°

Roof pebbles as per specialist Waterproofing by specialist

Dpc New Foundations to Engineers detail New Foundations to Engineers detail

Galvanized 50x50mm SHS panels. waterproofing by specialsit Precast Rectangular Column with Multi Layer Corbels to Engineers detail Gas fire place to specialist detail and specialist position

NGL

2.0m high Boundary wall from NGL. 220mm brick wall as per Engineers details & specifications. Plastered & painted

T +27 (0)67 296 4386 E levizdesignz@outlook.com www.levizdesigns.com

Raised platform to Engineers detail & specifications New Foundations to Engineers detail

Project status:

WORKING DRAWINGS

SECTION A-A & B-B

Issue date:

1/6/2023 3:29:04 AM

Clients Signature Engineers Signature & Reg No. Architect Signature & Reg No. Scale:

1 : 50

Project number:

P10 Drawn by:

Checked by:

Drawing number:

DO

JW

WD 301

REV

Copyright of these drawings are prohibited and may not be copied without the consent of Leviz Designs. Copyright 2022


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.