excel V+ brochure

Page 1


Precision & Performance in Vascular and Pigmentation Treatments

Engineered with a Purpose

With design input from leading dermatologists, excel V+ delivers the power, precision, and performance to safely and effectively treat a wide range of vascular and pigmentary conditions.

Featuring two clinically proven wavelengths, large spot sizes up to 16 mm, and high energy, excel V+ puts you ahead of the rest and expands your treatment capabilities.

Premium Technology

Two clinically proven wavelengths

truPulse™ energy delivery

Solid-state design with auto calibration

Enhanced Experience

Fully customizable treatments

Intuitive interface with pre-set parameters

Superior integrated contact cooling

Maximum ROI

No consumables or disposables

6 avenues of revenue

High throughput and patient satisfaction

More Than 30 Unique Treatment Applications

Facial Telangiectasia

Nasal Telangiectasia

Spider Veins

Reticular Veins

Cherry Angiomas

Spider Angiomas

Port Wine Stain

Hemangioma

Venous Lakes

Rosacea

Matting

Poikiloderma

Age Spots

Sunspots

Freckles

Dyschromia

Dermatosis Papulosa Nigra

Wrinkles

Skin Quality

Textural Concerns

Acne Scars

Surgical Scars

Surgical Bruising

Injectable Bruising

Chloasma

Verrucae (Warts)

Active Acne

Skin Tags

Small Area Hair Removal

Pseudofolliculitis Barbae

Power, Precision, and Performance

Clinically Proven Wavelengths

Effectively targets vascular and pigmented lesions, as well as skin revitalization concerns, with a high safety margin for all skin types

Enhanced Power1

excel V+ features a Lithium Triborate Laser Boosted Optic (LBO) and truPulse™ delivery, offering an enhanced range of specifications

This design ensures consistent energy delivery, performance, and reliability.

6 Versatile Treatment Options

COOLVIEW 1064 NM | 532 NM

Cutera's 1064 nm Nd:YAG laser is a safe and effective solution for treating vascular lesions on skin types I-IV. The versatile Coolview 1064 extends treatment capabilities, delivering effective solutions for hair removal and wart treatment on all skin types.

The 532 nm wavelength, well absorbed by oxyhemoglobin and melanin, effectively targets superficial vascular and pigmented lesions like rosacea and photodamage on skin types I-IV.

DERMASTAT 532 NM

Enhanced precision and versatility to quickly trace discrete vascular and pigmented lesions on skin types I-III on the face and body with ease. Available in a 1 or 2 mm spot size handpiece.

Fast Treatments

With adjustable spot sizes from 1-16 mm, excel V+ boosts practice efficiency, enhances throughput, and maximizes ROI.

Patient Comfort and Safety

Integrated sapphire contact cooling, adjustable from 5-20 °C, cools before, during, and after each pulse.* Cooling can be adjusted based on treatment needs, with increased cooling for vascular treatments and less cooling for pigment treatments.

*Only available on the Coolview handpiece

Signature Genesis Treatments

LASER GENESIS 1064 NM

Cutera’s signature treatment, Laser Genesis, delivers gentle micro-pulses of laser light to target the microvasculature in the skin and stimulate collagen production to improve the appearance of fine lines, wrinkles, and scars.

GREEN GENESIS 532 NM

A unique micro-pulsed treatment designed to address reds and browns on the face and body, comfortably, with no downtime. The signature Genesis treatments offer an all-around nonablative skin revitalization treatment to improve the skin's color, tone, and remodel collagen.

excel V+ Results

COOLVIEW 532

Photodamage

Diffuse Redness

COOLVIEW 532 &

Photos courtesy of K. Stankiewicz, MD
Photos courtesy of V. Ross, MD Veins
Photos courtesy of S. Ronan, MD
Rosacea
Photos courtesy of Stirling Skin Care Clinic

COOLVIEW

- 16 mm

Cooling Contact Sapphire, Adjustable 5 - 20˚C

-

References: 1 Scott Prahl, Oregon Medical Laser Center: http://omlc.org/spectra/hemoglobin/

Indications for Use: The excel V+ 532 nm wavelength is indicated for the coagulation and hemostasis of benign vascular and cutaneous lesions in dermatology including, but not limited to, the following general categories: Benign vascular lesions, including angiomas, hemangiomas, port wine stains, venous anomalies, telangiectasia (facial or extremities), leg veins and poikiloderma of Civatte; Benign pigmented lesions, including nevi and lentigines; Benign cutaneous lesions, including warts and scars; Chloasma. The excel V+ 1064 nm wavelength is indicated for the coagulation and hemostasis of benign vascular and cutaneous lesions in dermatology including, but not limited to, the following general categories: Benign vascular lesions, including port wine stains, hemangiomas, warts, telangiectasia, rosacea, venous lake, leg veins, spider veins and poikiloderma of Civatte; Benign cutaneous lesions, including warts, scars and striae; Benign pigmented lesions, including seborrheic keratoses and nevi; Chloasma; Mild to moderate inflammatory acne vulgaris. The 1064 nm wavelength is also indicated for the treatment of wrinkles such as, but not limited to, periocular and perioral wrinkles. Contraindications: Pregnant patients; Patients undergoing treatment for skin cancer. Important Safety Information: The following treatment-related expected transient side effects and possible adverse events may occur during or following treatment with excel V+: Erythema; Edema; Purpura; Hyperpigmentation; Hypopigmentation; Burns; Erosion; Epidermal crusting; Blistering; Scarring; Deep tissue injury; Prolonged wound healing; Temporary or permanent gray hair; Stimulation of terminal hair growth; Undesired hair loss in hairbearing areas; Red rash/bumps; Hemosiderin staining; Textural changes; Cutaneous indentations; Sun exposure, tanning beds, and artificial tanning mat increase the risk of side effects and adverse events. Warnings: Do not treat over dysplastic nevi or questionable pigmented lesions. Do not treat over or close to tattoos or permanent make-up. Precautions: Photosensitizing drugs (Tetracyclines, etc.); Be aware that you may have to adjust the treatment parameters according to clinical response from test area(s). Anticoagulants may increase risk of purpura or bruising; History of coagulopathies; History of keloids or hypertrophic scarring; Diabetes may impede wound healing; History of herpes; Pre-treatment with an antiviral may be indicated. Isotretinoin (Accutane/Roaccutan) use; History of vitiligo. Refer to the Operator Manual to view the laser safety labels of the product.

Intended for North American audiences.

©2025 Cutera, Inc. All rights reserved. AP2429 rG (03/25)

About Cutera

Cutera was founded in 1998 by veteran laser and optical engineers who envisioned that technology should and could do more. We have since grown into a global leader of dermatology and aesthetics devices that appeal to forward-thinking clinicians who seek the next generation of performance, safety, and efficacy.

Cutera, Inc. World Headquarters | 3240 Bayshore Boulevard, Brisbane, California 94005 USA 888-4-CUTERA or 415-657-5500 | info@cutera.com | cutera.com