Coryn Carr | Special Use | Spring 2011
Programming
Executive Summary 6 Analysis of Existing 8 Research 10
Schematic Design
Conceptual Frame Work 20 Glance at Green 30
Design Development
Floor Plans 37 Focus Areas 40 Wayfinding 48
Codes
Programming Codes
Work Cited 60
References
56
Coryn Carr | Special Use | Spring 2011
Programming
Coryn Carr | Special Use | Spring 2011
Programming
Four Corners Design is a new design firm that specializes in the four corners region. We provides high quality, environmentally friendly, and affordable senior living facilities, that function efficiently in all aspects of sustainable design. We strive to create comfortable and healthy environments that mimic the green house model to further enhance the wellbeing of the residents. Swallowtail retirement community is a facility for adults ages sixty five and older located in Phoenix Arizona. The facility has accommodations for seniors needing additional help with everyday activities. We have an assisted living unit as well as a memory care unit to meet all your needs. Included in the facilities is a clinic with a full time doctor and nursing staff, a administration area and a immaculate town center that is open to the public. The town center features a two story waterfall combined with a green wall, a full service beauty salon that is open to the public, an outdoor pool and fitness room, a craft room, day-care, theater, workshop, retail shop post office and a cafe with all organic food grown on site.
Swallowtail | 6
Programming
Executive Summary
Concept Metamorphosis: The Idea of Transformation
Vision To create a place that is beautiful, calming and engaging where the elderly can easily transition from their homes into a healthy and secure environment.
Design Statement To transform a space into an easily accessible, inviting and useful environment that fosters an easy way of life. Sustainable design the facility incorporates natural daylight throughout, energy efficient appliances, low flow fixtures and voc- free materials. The warm color scheme with punches of vibrant color and organic shapes reflect the natural world connecting the individual with nature.
Swallowtail | 7
Programming
Site Analysis
I am going to be designing a retirement community that will incorporates assisted living and memory care, as wells as a clinic and several amenities to appeal to the active elderly of the region. The facility will be located in Phoenix, Arizona. Currently there are a number of retirement communities and nursing home facilities in the Arizona region but few that demonstrate the new model of facilities that make these places a place of destination. The climate in this area is the main reason for this location. In the winter the average temperature is 60 degrees and of course in the summer it can get up to a 110 or more. It is sunny all year round and makes it a happy and joyable place to live. The facility will be urbanely located in order to have easy access to shopping malls and public transportation. This site has the several opportunities for sustainable design.
Swallowtail | 8
Programming
Client Profile
The retirement community has grown 45% in the Arizona region since 2009. With the economy the way it has been families have not had the extra time or money to take in another mouth and body to take care of which is where FCD come in. Retirement communities are changing and are now a place where people want to go and live out their lives in a fun and relaxing environment with no or little responsibilities. The owner of the this facility want it to be a place that his staff and the residents want to be. By doing research based design this facility will have the leading for front of the new models of retirement communities. It will be a healthy place for staff, residents and the community.
Swallowtail | 9
Programming
Resident Quality of Life
Quality of Life
Designing for Life’s Party - Having plenty of activity areas: - Craft Room - Art Room - Music Room - Garden - Movie Theater - Game Room - Selecting a site that is within walking distance to restaurants, shop ping malls and movie theaters...etc. - Designing areas for groups to congregate indoors and outdoors
Case Study
Heritage Club: Denver, Colorado - Have fun and celebrate life everyday - Daily activities - games - outings - movie nights - meet and greets - many more - Not letting age bring them down and living life to the fullest
Swallowtail | 10
Programming
Nurse Stations
Nursing Stations - Decentralized nursing stations
- Reduce nurse travel time - Increase time with patients
- Provide technical program in exam rooms
Case Study
Sanctuary at Wilmington Place “ Pod Concept� Design - Neighborhood living - better access to shabaz - more varied social encounters - Decentralized Nursing Stations - reduces nurse fatigue: walks 50% less - increases time with patient - decreases noise level - Install patient monitoring systems to check real time vitals - 2 pods: 1 for assisted living 1 for skilled nursing - Continuous hallway with interior court yard - allows residents to walk uninterrupted without running into dead end corridors - interior courtyard is secure and allows staff to monitor residents
- Nursing station are strategically placed throughout the corridor
Swallowtail | 11
Programming
Snoezelen/ Rummage Room
How to build a Snoezelen Room
- Can be built to fit any room - Designed for calming and relaxation - Stimulation the Senses - Visual -Bubble Tubes - Fiber Optics - Solar range projects with effect wheels and music - Touch - Variety of mats, textures and cushions - Sound - Different sounds and soothing music - Smell - Aromatherapy centers - Master Systems - Ball pools - Weighted items - Rockers - Swings - Soft furniture
Case Study
Buckner Villas Retirement Services: Austin, TX
Findings - Residents all like something different - Something that may calm one person may upset another - Helps calm residents with memory care issues - Residents need to be accompanied by a shabaz - Staff has noticed improvements in residents that use the rooms - Incorporate aspects of snoezelen room into traveling nurses station
Swallowtail | 12
Programming
Sustainable Senior Living Sustainable Senior Living
- Provide lots of natural day light - Provide views of nature - The use of operable windows - Natural ventilation - Good indoor air quality - Green energy: solar panels - VOC free materials - Thermal Comfort - Use of local materials - Water efficiency - Energy efficiency - Site orientation - Green roof - Recycling program in place
Case Study
Synergy Assisted Living Facility: San Francisco, CA
Building - 6500sf - 3 story wood frame construction Achievements - Optimized performance - Minimize maintains and energy use - Natural day light: use of void in core -Green roof - Natural air ventilation - Stack ventilation - Light Shelf
Swallowtail | 13
Programming
Ergonomics
1. Safety And Wellbeing
3. Ease of Use
Mobility and Functional Ability - ADA - All entries and corridors are to be accessible - Provide elevators throughout - All counters and tables are to meet ADA requirements - Pool area is to meet ADA requirements with an Aquatics Accessible Guidelines - Universal Design - Provide grab bars on all stairs and restrooms - The use of wide door frames for easy wheelchair access - Controllably of thermal comfort in all residents rooms - Specify roll in showers in all residents bathrooms - Use lever handles for ease of use - Provide several rest areas throughout corridors - Anthropocentric - Provide plenty of space for 5’-0� turn around in kitchen, dining, living restrooms and resident rooms - Provide areas for exercise and activities - Specify easy access drawers and doors - Wayfinding Strategies - Design in loops - Avoid dead end corridors - No locked doors at end of corridors - Lead residents to a destination without being obvious - Provide seating areas throughout corridors - Keep residential scale - Provide signage at eye level or below - Provide familiar clues for residents that become disoriented - Keep different areas separate by color, materials and icons
Security - Locked medication cabnets in all residents room - Residents have are able to lock their doors -Safety comes first - Work Place Safety Hot line Lighting Quality - Lots of natural day light with views into residents rooms - Tall windows with shading - Specify high performance lighting - Put all fixtures on dimmers for efficiency - Use of warm lighting makes residents feel welcome - Use tall windows - Residents controllability of light 2. Comfort and Sense of Choice and Control Privacy - Locked doors to resident rooms - Private restrooms no communal baths - Provide acoustical privacy in all resident rooms Assisted Living - Provide decentralized shabaz stations - Avoid floor changes to prevent falling - Avoid dark colors like purple because the ageing eye sees gray -Specify large graphics for ease of visibility - Specify furniture with firm cushions and arm rest Memory Care -Provide areas for wondering - Avoid dead end corridors - Provide decentralized shabaz stations - Limit floor changes - Specify durable materials Swallowtail | 14
Programming
Ergonomics 4. Productivity/ Performance Staff - Provide a break rooms for staff to get away - Keep a 1:5 ratio with staff and residents - Keep the staff happy Resident Daily Activity - Provide space/ rooms for games and activities - Provide a Wii room - Provide places for residents to relax and converse - Provide shabaz stations throughout 5. Aesthetics Color - Use bright vibrant colors that the aging eye can easily see - Use of yellow adds sunshine to a space - Avoid dark/dull colors - Create a home like atmosphere Contrast - Contrast adds character to a room - Avoid busy patterns - Avoid high contrast on ground, it may look like a step to the aging eye - High contrast on signage - Specify textured fabrics and materials - Avoid the use of shinny materials because of glare Lighting Quality - Provide windows in all areas possible - Provide wall scones on all entries for wayfinding - Provide a light over residents entry
Swallowtail | 15
Programming
Research Based Design
Research shows that creating an environment for residents that feels like home makes it easy for them to transition from their homes to a facility with care. Providing lots of natural daylight and views of nature eases the residents and makes it a place where staff, residents and their families want to be. Research based design drives the project and makes it a place where people want to live and work.
Swallowtail | 16
Programming
Design Strategies Design Strategies For Resident Room
- Provide natural daylight through large windows into the bedroom, living room and kitchen - Provide seating in bedroom for dressing - Specify furniture that has a residential feel - Allow residents to bring person artifacts and furniture to occupy their rooms - Comply with ADA
General Design Strategies
- Provide lot of natural daylight in all spaces - Avoid dead end corridors - Provide ample resting areas along corridors - Minimize floor changes in color and material - Use colors that are kind to the aging eye - Specify all chairs and sofas with arm rest and firm cushions - Comply with ADA
Swallowtail | 17
Schematic Design
Coryn Carr | Special Use | Spring 2011
Schematic Design
Conceptual Frame Work Town Center Criteria Matrix Area
Building Lobby/ Reception
Quantity
1
SF
590
Adjacency
Central
View
Yes
Public Access
Yes
DayLight
Yes
Privacy ( Accustic=A, Plumbing Visual= V)
A
Yes
1 810
1,5
Yes
Limited
Yes
V,A
No
Beauty Salon
1
450
1
Yes
Yes
Yes
V,A
Yes
Physical Therapy/ Gym
2
880
1
Yes
Yes
Yes
V,A
Yes
1
800
1
Yes
Yes
Yes
No
Yes
2
150
1
No
No
No
V
Yes
1
800
1
Minimal
Yes
V,A
No
Flexable seating for groups of 2-4 Large sink for bugets and cleaning utensils; shelves for cleaning supplies Flexable seating for 50; projector; screen; movie real; dvd player; small stage; popcorn machine;
1
830
Central
No
Yes
No
V,A
Yes
Restrooms need to be to code, and ADA
Indoor Garden
1
320
Central
Yes
Yes
Yes
No
Yes
Art Room
2
190
1000
Yes
No
Yes
V
Yes
Music Room
2
300
600
Yes
No
Yes
A
No
4 5 CafĂŠ Janitors Closet
Theater/ multi functional 7 gathering area Public 8 Restooms
10 11
Special Use Spring 2011
Swallowtail | 20
Task lighting for reading, comfortable seating for reading, bookcase for buildings private book collection, storage for games, game tables, collabrative areas for 4 two stations, two washing bowls, storage for towels and product, Pedicure chair, nail station, 3 dryers, tv, dvd player, 2 mirriors at stations
1
3
9
Air lock entry, reception desk, varity of lobby seating, central circualtion vertical and horizontal, public access to restrooms to code, access to gardens/ outdoor activities area. Reception desk, personal copmuter ( 21"w X 21"d X 17'h), at least one buff; transaction counter; 18lf lat. files easy to reac.
Library 2
6
Special Equipment
Minimal
Exam table; treadmill; bicycle; weight machine; water dispenser; mirriors across walls; medican balls and storage; bouncy balls and storage; floor mats (yoga mats) and Storage; comfortable flooring
Tables and chairs for groups of 2-4 for relaxation; plants; trees; flowers Easel (x6); Utility table 42" X 24" (x6); shelf 18" above utility table; tabpret(x6); activity zone 48"x 48; Piano; muicals instument storage; flexable seating for task and watching Coryn Carr
Schematic Design
Conceptual Frame Work Administration/ Clinic Criteria Matrix Quantity
SF
Adjacency
Views
Public Access
DayLight
Privacy ( Accustic= A, Visual=V)
1
10
Clinical Central
No
No
Yes
No
No
Executive Directors Office
1
360
3,4
Yes
No
Yes
V,A
No
2 Assistiants office
1
300
2
Yes
No
Yes
No
No
1 Assistants Office
1
200
2
Yes
No
Yes
No
No
Social Workers Office
1
200
2
Yes
No
Yes
V,A
No
Wellness Director
1
200
2
Yes
No
Yes
V,A
No
Activity Director
1
200
2
Yes
No
Yes
V,A
No
Staff Break Room
1
600
Centeral
Yes
No
Yes
V,A
Yes
Staff Restrooms
1
400
Central
No
Yes
No
V,A
Yes
Conference Room
1
250
Central
Yes
Yes
Yes
A
No
Copy/ Print Room/ Staff Mail Room
1
170
Central
No
No
Yes
V,A
No
Central
Yes
Yes
Yes
No
No
Central
No
Yes
No
V,A
Yes
Area Administration 1 Private Entrance 2
Plumbing
Special Equipment
Air tight double doors; ADA 18-22sf executive desk and chair; 2 pull up guest chairs; personal comp.; 2 BBF peds; 16-20lf; 50lf shelving; conference seating for 4 30" X 60" Desk; 20" X 30" work surface (x2);personal comp.(x2); BBF(x2); Shelving for books and other iteams; task chair for each desk; guest chair for each desk; small table for 4 for meetings 30" X 60" Desk; 20" X 30" work surface; personal comp.; BBF; Shelving for books and other iteams; task chair ; 2 guest chair; 30" X 60" Desk; 20" X 30" work surface; personal comp.; BBF; Shelving for books and other iteams; task chair ; 2 guest chair; 30" X 60" Desk;20" X 30" work surface; personal comp,: BBF; Shelving for blooks and other iteams; task chair; 2 guest chairs; 30" X 60" Desk; 20" X 30" work surface; personal comp.; BBF; Shelving for books and other iteams; task chair ; 2 guest chair; 10sf open counter space with base and wall cabinets; flexible seating for 10 that accommodate groups of 2-6 people; service station for supplies; sink bowl; small range; small REF; under counter dishwasher; 2 burner coffee marker; cabinet hung microwave
3 4 5 6 7
8 9 10
11 Clinical
Male a and female restrooms; ADA; showers; lockers 12-18" X 60-72"; bench; Seating for 10; credenza; 8-10lf mb; 6lf recessed projection screen; 10sf storage closet 17"wX27"dX38"h free standing copier ( requires 56"w space for maintenance) 60"wX24"dX36"h mail sorting table with 48"wX9"d26"h mail sorting hung above; closet 30sf general storage; employee coat closet with 6lf hanging rod
Administration Small Reception Desk 12 13 Public Restrooms 14
1
400
1
Visiting Doctors Office
1
300
15
Yes
No
Yes
V,A
Yes
Patient Exam Room
2
900
12,14
Yes
No
Yes
V,A
Yes
Laundry Room
1
None
No
No
No
V,A
15 16
Yes
Personal comp.; at least one BBF; transaction counter; 18lf lat. Files easy to reach; waiting room seating for 6 2 ADA unisex restrooms to code 30" X 60" Desk; 20" X 30" work surface; personal comp.; BBF; Shelving for books and other iteams; task chair ; 2 guest chair; exam bed 87" X 39"; bedside cabnet; medical wall unit; IV track and pendent system; 30" min circulation zone around bed; doctors task chair; exam task light; guest lounge chairs; storage for patients personal belongings Washer and Dryer; counter space for foulding clothes; laundry baskets for sorting
Swallowtail | 21
Schematic Design
Conceptual Frame Work Assisted Living Area
1
Residents Room:
Quantity
SF
Adjacency
Public Access
12
480
2,
No
Common Areas: Living Room
Views Yes
DayLight
Privacy ( Accustic=A, Visual= V)
Plumbing
Yes
V,A
Yes
4 5
6 7 8 9 10
Swallowtail | 22
Bedroom;ADA bathroom; small kitchenet; small dining area; living space; everything needs to be ADA
1587 2
315
1
No
Yes
Yes
No
No
1,5
No
Yes
Yes
A
No
2 3
Special Equipment
Dining Room Private Dining Room
2
270
6
No
Yes
Yes
V,A
No
Kitchen
1
190
Central
No
Yes
Yes
No
Yes
Visiting Family Suite
2
182
4
No
Yes
Yes
V,A
Yes
Public Restrooms Outdoor Garden Storage Shabaz Station
1 1 1 2
260
Central
150 220
1,2,3,5
No No No No
No Yes No No
No Yes No Yes
V,A No V,A V,A
Yes Yes No No
Flexible seating arangemetns for 15 or more residents; TV with DVD player; Shelves for movies, book, ect.; task lighitng for tasks like reading and games Flexible seating for groups of 4 or less with option to combine tables to accommidate larger parties Sepearte dining room for familys; large dining table to seat 6 or more Full REF; sink; DW; upper and lower cabnets for storage; small closet for cleaning supplies 2 bedrooms; ADA bathroom; Full kitchen with range; REF; DO; DW; sink; living area; small dining area; stackable washer and dryer ( needs to be comfortable for families visiting guest for couple nights) ADA ADA Shelving Accomidate 2-3 shabazim
Schematic Design
Conceptual Frame Work Memory Care Criteria Matrix Quantity
SF
Adjacency
View
Residents Rooms Pod 1 Pod 2 Common Area for each pod
12 6 6
6680 3600 3080 2613
5,6 5,6 5,6 Central
Yes yes Yes
No No No
Yes Yes Yes
Living Room
2
300
Central
Yes
No
Yes
No
Flexible seating arangemetns for 15 or more residents; TV with DVD player; Shelves for movies, book, ect.; task lighitng for tasks like reading and games
2
350
Central
Yes
No
Yes
No
Flexible seating for groups of 4 or less with option to combine tables to accommidate larger parties
2
270
8,9
Yes
No
Yes
No
Sepearte dining room for familys; large dining table to seat 6 or more
2
170
1,5,6
Yes
No
Yes
Yes
Full REF; sink; DW; upper and lower cabnets for storage; small closet for cleaning supplies
Area 1 2 3 4 5
Dinign room 6 7 Private Dining room 8
9 10 11 12 13 14 15 16 17
Privacy ( Accustic=A, Visual= V) V,A V,A V,A
Public Access
Kitchen
DayLight
V,A
Plumbing Yes Yes Yes
Visiting Family suite
2
180
7
Yes
No
Yes
V,A
Yes
Laundry Room Passive Snoezlen Room Active Snoezelen Room Rummage area/ room Public Restrooms Outdoor Patio Storage Shabaz Stations
2 2 2 2 2 2 4 2
120 160 160 150 260 200 98 195
1,2,3 17 17 5 Central Central 17 1,16
No Yes No No No Yes No No
No No No No No No No No
Some No No Yes No Yes No Medium
V,A V,A V,A
Yes Yes Yes No Yes No No No
V,A V,A V,A
Special Equipment
2 bedrooms; ADA bathroom; Full kitchen with range; REF; DO; DW; sink; living area; small dining area; stackable washer and dryer ( needs to be comfortable for families visiting guest for couple nights) For residents only,
ADA; male and female to code Felxable Seating for groups of 2-4; swings; plants Shelving Accommodates 2-4 shabazim
Swallowtail | 23
Schematic Design Conceptual Frame Work
Swallowtail | 24
Schematic Design Conceptual Frame Work
Swallowtail | 25
Schematic Design Conceptual Frame Work
Swallowtail | 26
Schematic Design Conceptual Frame Work
Swallowtail | 27
Schematic Design
Conceptual Frame Work
Swallowtail | 28
Schematic Design
Conceptual Frame Work
Swallowtail | 29
Schematic Design Green at a Glance Recycled Content Recyclable material
Water Efficiency
Sustainable Sites
Indoor Environmental Quality
Energy Efficiency
Forest Stewardship Council Certified
Contains no VOCs
Energy Star Certified
Greengaurd Certified Indoor Air Quality Certified Regional Priority (LEED)
Innovation in Design (LEED)
Location & Linkages (LEED)
Education & Awareness (LEED)
SCS Certification Rapidly renewable resource
Swallowtail | 30
Schematic Design Green Guide for Health care Introduction “The Green Guide for Health Care is a superb resource. It helps the leaders and managers of health care institutions “walk the talk,” promoting the health of patients, visitors, employees, community members, and the global community while operating economically and efficiently. I hope that every medical center, hospital, and clinic in the nation gets a copy of the Green Guide, takes its lessons to the heart, and joins the growing movement toward healthier, more environmentally friendly environments in the health care sector.” Howard Frumkin, M.D., Dr.P.H. Director, National Center for Environmental Health/Agency for Toxic Substances and Disease Registry U.S. Department for Health and Human Services Centers for Disease Control and Prevention
Swallowtail | 31
Schematic Design Green Guide for Healthcare Environmental Quality
Prerequisite 1: Minimum Indoor Air Quality Performavvnce Intent:Establish minimum indoor air quality (IAQ) performance to enhance indoor air quality in buildings, contributing to the comfort and wellbeing of the occupants. Ventilation (refer to GGHC EQ Credit 2). Develop ventilation strategies tat support operable windows, where appropriate. Design for mechanical ventilation air change rates required by health code standards, zoning areas where contaminants are generated. Construction Methods (refer to GGHC EQ Credit 4). Control indoor air quality during construction and mitigate impact on occupied building air quality. Flush newly constructed or renovated buildings with 100% outside air prior to occupancy. Building Materials (refer to GGHC EQ Credits 4 & 8). Many materials and products used in the building emit volatile organic compounds (VOCs), including formaldehyde. Examples of possible sources of indoor air pollution include adhesives, paints, carpeting, upholstery, manufactured wood products and other components of furniture, including medical furniture & equipment. Chemical & Pollutant Source Control (refer to GGHC EQ Credit 5 and Operations). Sources can include outdoor pollutants, indoor chemical use (including glutaraldehyde and other sterilizing agents and methylene chloride, used in adhesive removers, paint stripper, and aerosol spray paints), cleaning products, fragrances and pest control activities. Building Maintenance and Operation (refer to GGHC EQ Credit 5 and GGHC Operations section). Control Systems (refer to GGHC EQ Credits 6 & 7). Install sensors for relative humidity, temperature, and carbon dioxide. Consider occupant control systems to improve individual comfort.
Goals
Swallowtail | 32
- Meet the minimum requirements of the relevant local licensing requirement for ventilation or Section 4 through 7 of voluntary consensus standard ASHRAE 62-2004, Ventilation for Acceptable Indoor Air Quality, whichever is more stringent. Mechanical ventilation systems shall be designed using the - Ventilation Rate Procedure or the applicable local code, whichever is more stringent. Naturally ventilated buildings shall comply with ASHRAE 62.1-2004, paragraph 5.1 or the relevant local licensing requirement, whichever is more stringent.
Design Strategies
- Prior to occupancy flush out the building with outside air. - Filter incoming air, and locate exhaust, smoking areas, and parking away from intake valves. - Specify low to no VOC finishes and adhesives. - Recommend non-toxic cleaning supplies.
Schematic Design Green Guide for Healthcare Prerequisite 2: Environmental Tobacco Smoke (ETS) Control Intent: Prevent exposure of building occupants, indoor surfaces, and ventilation air distribution sys-
Prerequisite 3: Hazardous Material Removal or Encapsulation
tems to Environmental Tobacco Smoke (ETS)
Intent: Reduce the building occupant’s potential exposure to asbestos, mercury, lead, and
Locate any exterior designated smoking areas at least 50 feet (15.24 meters) away from entries, operable windows, air intakes, bus stops, disabled parking, and other locations where occupants could inadvertently come in contact with ETS when occupying, entering or leaving the building.
Identify applicable regulatory requirements.
Only for residential facilities where the functional program requires accommodation for smokers may there be an exception to establish negative pressure smoking rooms: Provide one or more designated smoking rooms designed to effectively contain, capture and remove ETS from the building. At a minimum, the smoking room must be directly exhausted to the outdoors with no re-circulation of ETS-containing air to the non-smoking area of the building, and enclosed with impermeable deck-to-deck partitions. With the doors to the smoking room closed, operate exhaust sufficient to create a negative pressure with respect to the adjacent spaces of at least an average of 5 Pa (0.02 inches of water gauge) and with a minimum of 1 Pa (0.004 inches of water) when the door(s) to the smoking room are closed. Verify performance of the smoking room differential air pressures by conducting 15 minutes of measurement, with a minimum of one measurement every 10 seconds, of the differential pressure in the smoking room with respect to each adjacent area and in each adjacent vertical chase with the doors to the smoking room closed. Conduct the testing with each space configured for worst case conditions of transport of air from the smoking rooms to adjacent spaces with the smoking rooms’ doors closed to the adjacent spaces.
Goals
- Prohibit smoking in the building (except as noted below).
Design Strategies
- Prohibit smoking in the building; - Provide outdoor areas where residents and visitors can smoke.
mold; and, prevent associated harmful effects of these hazardous materials in existing buildings. (New construction projects are exempt from compliance with this Prerequisite.)
Obtain Survey records that identify known contamination in the building and on the site. Survey locations where hazardous materials may be present in previously uninvestigated areas of the building and site. Include a plan for capture of historical mercury sources during demolition, including but not limited to piping infrastructure. Designate collected mercury devices for recycling that precludes overseas donation/disposal. Remove and properly dispose of disconnected wiring that contains lead stabilizers. Provide contract requirements for reporting and investigating suspect mold encountered in demolition. Remediate contaminated surfaces: remove and dispose of contaminated materials in accord with recognized procedures that protect works, building occupants and the public.
Goals
Design Strategies
- Establish a program for the discovery, testing and mitigation of asbestos, mer cury, lead and mold
- This project is new construction, therefore does not have to comply with this prerequisite. - Implement a mandatory recycling program for waste and other materials to be recycled.
Swallowtail | 33
Design Development
Coryn Carr | Special Use | Spring 2011
SITE PLAN
Design Development Site Plan
Swallowtail | 37
CORYN CARR| SPECIAL USE| SPRING 20
Design Development
FLOOR PLAN Floor FIRST FLOOR
Swallowtail | 38
Plan: First Floor
CORYN CARR| SPECIAL USE| SPRING 2011
FLOOR PLAN SECOND FLOOR
Design Development
Floor Plan: Second Floor
Swallowtail | 39
Design Development
EARL ‘S Resident ROOM Room
EARL IS A 91 YEAR YOUNG MAN WHO IS SUFFERING FROM ADVANCE STAGES OF ALZHEIMER’S DISEASE. IN HIS EARLY YEARS HE WAS A BRILLIANT CHEMIST AND PROFESSOR FOR OVER 40 YEARS. HE HAS 2 DAUGHTERS AND SEVERAL GRAND CHILDREN THAT WOULD BE VISITING HIM ON A REGULAR BASIS. HIS FAMILY ASK THAT THE SPACE BE DESIGNED IN A WAY THAT IS SIMPLE, SAFE AND ALLOWS FOR THE FREEDOM OF MOBILITY. THEY ALSO ASK THAT WHERE EARL CANNOT HURT HIMSELF, SINCE THOSE WHO HAVE ALZHEIMER’S TEND TO GET CONFUSED EASILY AND THROUGH EPISODES OF ANGER. IT IS MOST IMPORTANT THAT EARL CANNOT HURT HIMSELF. SWALLOWTAIL RETIREMENT HOME WILL BE THE BEGINNING TO A NEW START OF EARL’S LIFE.
Swallowtail | 40
EARL ‘S ROOM
Design Development
Resident Room
DESIGN SOLUTIONS: -CURVE ALL CORNERS OF WALLS AND
COUNTERTOPS FOR SAFETY -MINIMIZE THE CHANGE IN FLOORINGS TO PREVENT FALLING -PROVIDE CLUES SUCH AS ART WORK, PAINT AND CHANGE IN FLOORING MATERIALS TO REMIND THE RESIDENTS WHERE THEY ARE IN THEIR ROOMS ex) the bedroom has carpet floors and navy blue walls to indicate a comfort and sleep -PROVIDE LOOPED CIRCULATION TO ALLOW RESIDENT TO WANDER SAFELY IN ex) the entry leads into kitchnet then to living room or bedroom and the bath has two doors that lead into the bedroom and the living room -A CABINET IN THE KITCHENT HAS A LOCK FOR MEDICATIONS -TRY TO MAKE THE FEEL AS MUCH AS HOME AS POSSIBLE BY LETTING THEM BRING THEIR OWN FURNITURE AND SURROUNDING THEM WITH THINGS FROM THEIR PAST. -APPLY THESE STRATEGIES TO ALL MEMORY CARE UNITS
Swallowtail | 41 CORYN CARR| SPECIAL USE| RESIDENT ROOM
Design Development
Focus Area: Circulation
Circulation Through elevations and sections the circulation of the town center and Wren Care unit is demonstrated here. When you first walk into Swallowtail Retirement Community you are confronted with a beautiful two story living wall/ fountain combination. Adjacent to the two story feature is the reception desk, elevators and the beauty salon. Just past the elevators is the rest of the town center like the mail room, retail store, work shop, cafe, theater, fitness room, day-care, craft room and the outdoor pool. Just above the beauty salon is the town center library. The library is small and gives a residential feel. The books that will be occupying the shelves will be residents books or books that are donated to the facility. There are several places to sit and read or relax on the second floor of the town center which over looks the water feature and the front entry.
Swallowtail | 42
Design Development
Focus Area: Wren Care Wren Care Circulation
The Wren Care unit consist of two pods split between two floor. Each pod contains six residents, each having their own communal kitchen, living room and dining room as well as a private dining room that can be multi functional. Every entrance into the residents rooms is indents and contrasted with a darker color. The door is illuminated from above to indicate that it is an entrance. In front of every resident room there is a place for them to display memorabilia to cue them that the room is theirs. The Wren care unit features a grand stair case to connect the two pods together. Research has shown that people with memory issues tend to wonder. Research also shows that elders with memory problems are not necessarily physically disabled in anyway they just can remember certain memories more so the recent ones. In an effort to provide residents with a safe outlet to wander these stairs were put in place. These stairs are the safest stairs there are with railings on both sides and bench on the landing for the residents to relax. There also is a shabaz at the bottom of the stairs that will monitor the activities on the stairs.
Swallowtail | 43
Design Development
Focus Area: Theater
Theater Room The teater is a multi funtional room where residents and members of the community can enjoy a movie in a theater like atmopsher or have a game night with Wii to get the residents up and moving. This room can be used for many purposes. The chairs in the theater are custom designed will a movable round table and drink older. The chair are light weight and easy to move around. The room is full ADA accessable with a service bar at the back of the theater and a small stage at the front. The floors in the space are cork and carpet to help with accustical issues and comfort.
Swallowtail | 44
Design Development
Focus Area: Cafe Cactus Comfort Cafe The Cactus Comfort Cafe in the town center is an all orgainic quisen. All the food product sold in the cafe is either locally grown or pulled straight from the community garden on site. The cafe features a green window as well as an outdoor patio with two fire places. There are several different dining experince that one could have in this cafe. The cafe is floaded with natural day light by the floor to ceiling windows on the south side of the buildings. All the finishes in the cafe contain recyceled content or are local materials. The cafe creates a comforting atmospere where people can sit and enjoy a healthy meal.
Swallowtail | 45
Design Development
Focus Area: Work Shop
Work Shop The workshop is part of the town center that cators to men. The workshop is a place for the men to be creative and handy. The workshop would only be open certan hours of the day and would always have a staff on duty to help an monitor the residents useing the room.The crafts made in the workshop can be sold in the own center retail store or given to family members. It is up to the resident that made it to decide where their worksmenship goes.
Swallowtail | 46
Design Development
Focus Area: Beauty Salon
Beauty Salon The beauty salon is a full service salon that is also open to the public. The salon incorporates water efficient fixtures and energy efficient appliances. The shampoo is combined into the hair dresser station to minimize the amount the resident has to move from chair to chair. On that note the salon is ADA compliant and all chairs are light and easy to move around to proved room for wheel chairs and walkers. The finishes used in the salon are all extremely durable and stain/ water residents. Large windows occupy two walls of the salon letting in an abundance of natural daylight making it a place people want to be.
Swallowtail | 47
Design Development
Swallowtail | 48
Design Development Wayfinding
Iconic Wayfinding Each department of the facility models the colors of the region and displays an icon of the Arizona. Using a high contrast image allows for the residents to easily identify without this image is. Having a solid white icon on a colored background cues the user of their location in the facility.
TOWN CENTER
CLINIC
ADMINISTRATION
ASSISTED LIVING
CACTUS COMFORT CAFE
WREN CARE
Swallowtail | 49
Design Development
Wayfinding
General Wayfinding These recognizable signs will be used throughout the facility. In an effort to layer wayfinding the signs are color coded to the area where they will be located. For example the town center color is mandarin and all the elevator signs stair and restroom signs will be shown in that color. The same goes for the administration area which is red, the clinical area which is blue, purple for assisted living and yellow for the wren care (memory care unit.
Swallowtail | 50
Design Development Wayfinding ASSISTED LIVING LIVING ROOM KITCHEN DINING AREA PRIVET DINING ROOM RESTROOMS STAIRS SHABAZ STATION RESIDENTS ROOM
WREN CARE SHABAZ STATION KITCHEN DINING PRIVATE DINING SNOZELON ROOMS RESIDENTS ROOM RUMAGE AREA
Specialized Way finding ADMINISTRATION
CLINIC
CONFRENCE ROOM OFFICES BREAK ROOM
EXAM ROOMS
COPY ROOM
RESTROOMS
RESTROOMS
DOCTORS OFFICE
These signs can be locted throughout the facilities for easy navigation. They are also color coated as well as icon coated to coorispond with the area. The sigins will be made of two layers of 3form material. The bottom layer will have the icon and color of that area ( for example town center is swallowtail butterfly and mandrain). The top layer will be semi transparant and will have all the lettering and a small icon of the department. The layers of the signs add to the layering of wayfinding and will make it easy to navagate through the community. Swallowtail | 51
Design Development Wayfinding Wayfinding Floor Plans Theses floors plans demonstrate how the facility is separated into areas by the use of color. It also shows how one would navigate throughout the building and where signs would be located.
WREN CARE TOWN CENTER CAFE ADMINISTRATION TOWN CENTER
CLINIC
ADMINISTRATION CONFRENCE ROOM OFFICES
CLINIC
EXAM ROOMS RESTROOMS DOCTORS OFFICE
BREAK ROOM COPY ROOM RESTROOMS
WREN CARE SHABAZ STATION KITCHEN DINING PRIVATE DINING SNOZELON ROOMS RESIDENTS ROOM RUMAGE AREA
FIRST FLOOR
Swallowtail | 52
CIRCULATION
Design Development Wayfinding
WREN CARE TOWN CENTER ASSISTED LIVING CIRCULATION ASSISTED LIVING LIVING ROOM KITCHEN DINING AREA PRIVET DINING ROOM RESTROOMS STAIRS SHABAZ STATION RESIDENTS ROOM
WREN CARE SHABAZ STATION KITCHEN DINING PRIVATE DINING SNOZELON ROOMS RESIDENTS ROOM RUMAGE AREA
SECOND FLOOR
Swallowtail | 53
Codes Coryn Carr | Special Use | Spring 2011
Codes
Programming Document Outline
1 Project Discription Building Square Foot= 48,212 (60% Building Effeciency) ( 22% Circulation Factor + 18% Misc) 60% Building Efficentcy = 28,928 s.f. (assignable) 40% Building Ineffectncy = 19,285 s.f.( circulation + misc) Program Usable = Assianable + Circulation 39,533sf = 28,927sf + 10,606sf
Swallowtail | 56
Codes
Plumbing( Minimum Number of Plumbing Fixtures: Table 2902.1 Area Occ. Class. Water Closets Lavatories Fountains M | W M|W Town Center Business 2 | 2 1 | 1 1 Note: Assume 50% male and 50% female unless specific demographics are provided Required Fire Separation ( Table: 508.3.3) Upon determined of Spatial Adjacencies/ Relationships, determine fire rating( in hours) between areas as required. Note: Areas not included below require no fire serperastion Area 1 Area 2 Separation in hours Assembly Business 2
Swallowtail | 57
References
Coryn Carr | Special Use | Spring 2011
Work Cited Growing Ageless (2011) Senior Living Retrieved From http://www.nmagelessliving.com/sls.htm Silverado Senior Living (2011) News Letter January 2011 Retrieved From http:// www.silveradosenior.com/mission_vision Life Quality of Denver (2010-2011) Secure Alzheimer Care Retrieved from http:// www.lifequalityhomesofdenver.com/Daily_Life_LQH_Denver.html Silverado Senior Living (2011) Silverado Senior Living Retrieved From http:// www.silveradosenior.com/p/dementia_care/scottsdale_photo_gallery/scottsdaleaz-85260/silverado-senior-living-2559 Boulder Associates (2011) Eskaton Gold River Lodge Retrieved From http://www. boulderassociates.com/portfolio/senior-living/project_02.jsp Shalom Park( 2011) Shalom Park Retrieved from http://www.shalompark.org.wvproxy.com/contactus/newsletter. htm Eskaton (2011)Livable Design Retrieved from http://www.eskaton.org/livabledesign.html Slide Share Inc. (2011) Periwinkle Senior Living Designs Retrieved From http:// www.slideshare.net/kathybradway/periwinkle-senior-living-designs-presentation John Wiley and Sons,( 2004) Building Type Basic for Senior Living: Engaging Wanderers, Retrieved fromhttp://www.architectureweek.com/2004/1215/design_3-2.html Aquatic Access Inc. (2006-2011) New Aquatic Access ADA Advisor for Public Pools and Spas Retrieved from http://www.aquaticaccess.com/aaihome.htm
RetrievedFromhttp://www.weather.com/weather/wxclimatology/ monthly/graph/USAZ 0166 Cityrating.com Relative Humidity (2002)Retrieved From http://www.cityrating.com/cityhumidity.asp?City=Phoenix Comparative Climatic Data�, National Climatic Data Center, NOAA, Wind� Average Wind Speed MPH (2001.) Retrieved From http://ggweather.com/ccd/avgwind.htm http://www.infoplease.com/ipa/A0108583.html Netstate LLC, The Geography in Arizona (2009)Retrieved From http://www.netstate.com/states/geography/az_geography.htm Network Communication, Mountain Living (2011)Retrieved From http://www.mountainliving.com/
Swallowtail | 61