TB3 Maintenance
The only routine maintenance required is cleaning. Surface tension changes can occur if proper routine maintenance is not conducted. Isopropyl Alcohol is recommended for surface cleaning.
• Catch Filter
Advertisement
• Syphon
• Interior of Bucket
• Top surface of adjusting screws
• Enclosure locking screws
• All insect screens
TB3 Calibration
• TB3 rain gauge is calibrated at the factory prior to shipment
• TB3 should hold its calibration for 100,000’s of events prior to a calibration being required
• Prior to conducting a calibration check, a thorough cleaning of the rain gauge is required
• most often a cleaning will bring the TB3 back into specified accuracy without having to do a calibration
Specified accuracy is +/- 2% for 0 to 100mm/hr.