Olympus AU640 and AU400 Systems ®

Refurbished by Carolina Chemistries Refurbished Olympus systems Barcoded ready-to-use reagents On-site installation and training Established peer group Warranty and service

by Carolina by Carolina by Carolina by Carolina by Carolina

When purchasing a chemistry analyzer you really only have two choices: New or Used Barcoded Reagents Warranty Established Peer Group Service Installation and Training

New

Used

√ 1 year √ >$15,000 √

√ 1 year √ <$15,000 √

Call 1-877-722-8910 for more information. www.carolinachemistries.com Olympus 640&400 flyer.indd 1

3/9/11 8:04:53 AM


Specifications

AU640

AU400

Analytical system

Fully automated, for routine, STAT, urine and homogeneous immunoassays

Fully automated, for routine, STAT, urine and homogeneous Immuno Assays

Analytical methods

Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE

Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE

Simultaneously processed analytes

48 photometric tests, 51 with ISE

Up to 38 photometric tests + 3 ISE

Throughput

800 photometric tests/hour; maximum of 1,200 with ISE

400 photometric tests/hour; maximum of 800 with ISE

Sample feeder

Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading

Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 80 samples; continuous loading

Sample tubes

In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm

In primary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm

STAT samples

Up to 22 positions for STAT samples, bar coded primary tubes

Up to 22 positions for STAT samples, bar-coded primary tubes

Sample volume

2 – 50 μl in 1 μl steps (1 – 50 μl for repeats)

2 – 50 μl in 1 μl steps (1– 50 μl for repeats)

Reagent supply

48 positions for R1 and R2; refrigerated (4 °C – 12 °C)

Refrigerated (4 °C – 12 °C); 76 positions for R1/ R2

Reagent volume

1. reagent: 25 – 300 μl; 2. reagent: 25 – 300 μl; (in 1 μl steps)

1. reagent: 25 – 300 μl; 2. reagent: 25 – 300 μl; (in 1 μl steps)

Total reaction volume

150 – 550 μl

150– 550 μl

Reaction cuvette

Quartz cuvettes

Quartz cuvettes

Reaction time

Up to 8 minutes, 40 seconds

Up to 8 minutes, 40 seconds

Reaction temperature

37 °C

37 °C

Mixing method

With rotating paddles after dispensing sample and reagent

With rotating paddles after dispensing sample and reagent

Photometry system

Direct assay through the reaction cuvette (0 – 2.5 OD) mono, bichromatic measurements possible

Direct assay through the reaction cuvette (0 – 2.5 OD) mono-, bichromatic measurements possible

Wavelength

13 different wavelengths between 340 – 800 nm

13 different wavelengths between 340 – 800 nm

Cuvette cleaning

Comprehensive cleaning with detergents

Comprehensive cleaning with detergents

Calibration

Auto calibration, cooled calibrator positions

Linear and non linear (linear interpolation), refrigerated calibrator positions

Test requisition

Individual and profile test requisition via on line, mouse, functions keys or touch screen

Individual and profile test requisition via on-line, mouse, function keys or optional touch screen

Safety

Clot detection and crash prevention for sample and reagent dispenser

Clot detection and crash prevention for sample and reagent dispenser

Software

Windows-NT®

Windows-NT®

On-line

Full uni- and bidirectional communication possible

Full uni- and bidirectional communication possible

Quality control

Auto QC, cooled QC positions

Dimensions (W x H x D)

74” x 50” x 32”

57.1” x 47.6” x 29.9”

575 N. Patterson Avenue, Suite 430, Winston-Salem, NC 27101 800-471-7272 or 336-722-8910 • fax 336-722-8915

Olympus 640&400 flyer.indd 2

clc-olym.v1-02/12

3/9/11 8:04:53 AM


Carolina Liquid Chemistries reagents for use on Olympus AU400, AU640, AU2700 & AU5400 Systems ®

Barcoded liquid ready-to-use • Barcode allows use of within lot calibration feature • Barcode tracks reagent position, expiry, and lot number • Pre-filled liquid ready-to-use R1 and R2 cartridges • On-board stability of 30 days

Unique chemistries • CO2 – 14-day calibration stability • Enzymes – don’t require daily blank • Homocysteine – low cost enzymatic • HbA1c – single channel • Lithium – low cost stable reagent

Full line of reagent tests • Menu of 60 different chemistries • Barcoded Drugs of Abuse tests including: Oxycodone, Burprenorphine and 6-Acetylmorphine • Complete line of multi-calibrators and controls • Ferritin, Transferrin, Lp(a), CRP • Service for AU Systems

Call 1-877-722-8910 for more information. www.carolinachemistries.com


Barcoded Reagents for use on Olympus Chemistry Systems General Chemistries

Item #

Description

Drugs of Abuse

Item #

Description

ALB

AU-224

3 x 250 tests

Alcohol w/cal

AU-421

2 x 625 tests

ALP

AU-206

3 x 250 tests

Amphetamine (AMPH)

AU-412

2 x 625 tests

ALT

AU-240

3 x 250 tests

Barbiturate (BARB)

AU-417

2 x 625 tests

AST

AU-241

3 x 250 tests

Benzodiazepine (BENZ)

AU-418

2 x 625 tests

Amylase

AU-227

3 x 100 tests

Buprenorphine (BUP)

AU-424

2 x 600 tests

APO A1

AU-632

3 x 200 tests

Cannabinoid (THC)

AU-410

2 x 625 tests

APO B

AU-633

3 x 200 tests

Cocaine (COCM)

AU-413

2 x 625 tests

BUN

AU-252

3 x 300 tests

Ecstasy (XTSY)

AU-423

2 x 625 tests

CA

AU-251

3 x 300 tests

Methadone (METD)

AU-415

2 x 625 tests

CHOL

AU-211

3 x 200 tests

Opiate (OP)

AU-411

2 x 625 tests

CK

AU-207

3 x 250 tests

Oxycodone (OXY)

AU-419

2 x 625 tests

CO2 w/cal

AU-313

3 x 250 tests

Phencyclidine (PCP)

AU-414

2 x 625 tests

CREA

AU-243

3 x 300 tests

Propoxyphene (PROX)

AU-416

2 x 625 tests

CRP hs

AU-645

3 x 100 tests

6-Acetylmorphine (6AM)

AU-425

2 x 600 tests

Cystatin-C

AU-691

2 x 100 tests

DBIL

AU-229

3 x 200 tests

ISE Reagents

Item #

Description

Ferritin

AU-694

3 x 100 tests

Buffer

AUH1011

4 x 2000 mL

Fructosamine w/cal

AU-612

3 x 80 tests

Cleaning Solution

AUH1019

4 x 100 mL

GGT

AU-209

3 x 300 tests

High Serum Standard

AUH1015

4 x 100 mL

GLU

AU-208

3 x 250 tests

Low/High Urine Standard

AUH1016

4 x 100 mL

HbA1c w/Lyse

AU-300

1 x 200 tests

Low Serum Standard

AUH1014

4 x 100 mL

HDLD w/cal

AU-616

3 x 250 tests

Mid Standard

AUH1012

4 x 2000 mL

Homocysteine w/cal

AU-201

1 x 150 tests

Na/K Selectivity Ck Solution

AUH1018

2 x 25 mL

Homocysteine w/cal Axis Shield

AS-201

1 x 150 tests

Reference

AUH1013

4 x 1000 mL

Insulin

AU-614

1 x 200 tests

Wash Concentrate

CC160

2000 mL

Iron w/cal

AU-618

3 x 200 tests

LDH

AU-205

3 x 300 tests

LDLD w/cal

AU-661

3 x 250 tests

Lipase w/cal

AU-621

3 x 100 tests

Lithium w/cal

AU-654

1 x 200 tests

Lp(a)

AU-204

3 x 400 tests

Microalbumin

AU-662

2 x 100 tests

Service

MG

AU-220

3 x 200 tests

PO4

AU-218

3 x 200 tests

Rheumatoid Factor

AU-629

3 x 100 tests

AU400 and AU640 chemistry analyzers include one-year service agreement with annual PM, parts, labor, and hotline support

TBIL

AU-228

3 x 300 tests

TIBC (direct)

AU-659

3 x 100 tests

TP

AU-217

3 x 250 tests

Transferrin

AU-641

3 x 100 tests

TG

AU-213

3 x 250 tests

URIC

AU-212

3 x 300 tests

Instruments Refurbished AU400 and AU640 chemistry analyzers with one-year warranty include installation and training.