Olympus AU640 and AU400 Systems ®
Refurbished by Carolina Chemistries Refurbished Olympus systems Barcoded ready-to-use reagents On-site installation and training Established peer group Warranty and service
by Carolina by Carolina by Carolina by Carolina by Carolina
When purchasing a chemistry analyzer you really only have two choices: New or Used Barcoded Reagents Warranty Established Peer Group Service Installation and Training
New
Used
√ 1 year √ >$15,000 √
√ 1 year √ <$15,000 √
Call 1-877-722-8910 for more information. www.carolinachemistries.com Olympus 640&400 flyer.indd 1
3/9/11 8:04:53 AM
Specifications
AU640
AU400
Analytical system
Fully automated, for routine, STAT, urine and homogeneous immunoassays
Fully automated, for routine, STAT, urine and homogeneous Immuno Assays
Analytical methods
Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE
Clinical chemistry and immunological parameters. End point, kinetic assays, fixed-time-kinetics, optionally ISE
Simultaneously processed analytes
48 photometric tests, 51 with ISE
Up to 38 photometric tests + 3 ISE
Throughput
800 photometric tests/hour; maximum of 1,200 with ISE
400 photometric tests/hour; maximum of 800 with ISE
Sample feeder
Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 150 samples; continuous loading
Racks with 10 samples each (barcodes on primary tubes and on racks); capacity of 80 samples; continuous loading
Sample tubes
In primary and secondary tubes; diameter between 11.5 and 16.5 mm; height between 55 and 102 mm
In primary and secondary tubes; diameter from 11.5 to 16 mm; height from 55 to 102 mm
STAT samples
Up to 22 positions for STAT samples, bar coded primary tubes
Up to 22 positions for STAT samples, bar-coded primary tubes
Sample volume
2 – 50 μl in 1 μl steps (1 – 50 μl for repeats)
2 – 50 μl in 1 μl steps (1– 50 μl for repeats)
Reagent supply
48 positions for R1 and R2; refrigerated (4 °C – 12 °C)
Refrigerated (4 °C – 12 °C); 76 positions for R1/ R2
Reagent volume
1. reagent: 25 – 300 μl; 2. reagent: 25 – 300 μl; (in 1 μl steps)
1. reagent: 25 – 300 μl; 2. reagent: 25 – 300 μl; (in 1 μl steps)
Total reaction volume
150 – 550 μl
150– 550 μl
Reaction cuvette
Quartz cuvettes
Quartz cuvettes
Reaction time
Up to 8 minutes, 40 seconds
Up to 8 minutes, 40 seconds
Reaction temperature
37 °C
37 °C
Mixing method
With rotating paddles after dispensing sample and reagent
With rotating paddles after dispensing sample and reagent
Photometry system
Direct assay through the reaction cuvette (0 – 2.5 OD) mono, bichromatic measurements possible
Direct assay through the reaction cuvette (0 – 2.5 OD) mono-, bichromatic measurements possible
Wavelength
13 different wavelengths between 340 – 800 nm
13 different wavelengths between 340 – 800 nm
Cuvette cleaning
Comprehensive cleaning with detergents
Comprehensive cleaning with detergents
Calibration
Auto calibration, cooled calibrator positions
Linear and non linear (linear interpolation), refrigerated calibrator positions
Test requisition
Individual and profile test requisition via on line, mouse, functions keys or touch screen
Individual and profile test requisition via on-line, mouse, function keys or optional touch screen
Safety
Clot detection and crash prevention for sample and reagent dispenser
Clot detection and crash prevention for sample and reagent dispenser
Software
Windows-NT®
Windows-NT®
On-line
Full uni- and bidirectional communication possible
Full uni- and bidirectional communication possible
Quality control
Auto QC, cooled QC positions
Dimensions (W x H x D)
74” x 50” x 32”
57.1” x 47.6” x 29.9”
575 N. Patterson Avenue, Suite 430, Winston-Salem, NC 27101 800-471-7272 or 336-722-8910 • fax 336-722-8915
Olympus 640&400 flyer.indd 2
clc-olym.v1-02/12
3/9/11 8:04:53 AM
Carolina Liquid Chemistries reagents for use on Olympus AU400, AU640, AU2700 & AU5400 Systems ®
Barcoded liquid ready-to-use • Barcode allows use of within lot calibration feature • Barcode tracks reagent position, expiry, and lot number • Pre-filled liquid ready-to-use R1 and R2 cartridges • On-board stability of 30 days
Unique chemistries • CO2 – 14-day calibration stability • Enzymes – don’t require daily blank • Homocysteine – low cost enzymatic • HbA1c – single channel • Lithium – low cost stable reagent
Full line of reagent tests • Menu of 60 different chemistries • Barcoded Drugs of Abuse tests including: Oxycodone, Burprenorphine and 6-Acetylmorphine • Complete line of multi-calibrators and controls • Ferritin, Transferrin, Lp(a), CRP • Service for AU Systems
Call 1-877-722-8910 for more information. www.carolinachemistries.com
Barcoded Reagents for use on Olympus Chemistry Systems General Chemistries
Item #
Description
Drugs of Abuse
Item #
Description
ALB
AU-224
3 x 250 tests
Alcohol w/cal
AU-421
2 x 625 tests
ALP
AU-206
3 x 250 tests
Amphetamine (AMPH)
AU-412
2 x 625 tests
ALT
AU-240
3 x 250 tests
Barbiturate (BARB)
AU-417
2 x 625 tests
AST
AU-241
3 x 250 tests
Benzodiazepine (BENZ)
AU-418
2 x 625 tests
Amylase
AU-227
3 x 100 tests
Buprenorphine (BUP)
AU-424
2 x 600 tests
APO A1
AU-632
3 x 200 tests
Cannabinoid (THC)
AU-410
2 x 625 tests
APO B
AU-633
3 x 200 tests
Cocaine (COCM)
AU-413
2 x 625 tests
BUN
AU-252
3 x 300 tests
Ecstasy (XTSY)
AU-423
2 x 625 tests
CA
AU-251
3 x 300 tests
Methadone (METD)
AU-415
2 x 625 tests
CHOL
AU-211
3 x 200 tests
Opiate (OP)
AU-411
2 x 625 tests
CK
AU-207
3 x 250 tests
Oxycodone (OXY)
AU-419
2 x 625 tests
CO2 w/cal
AU-313
3 x 250 tests
Phencyclidine (PCP)
AU-414
2 x 625 tests
CREA
AU-243
3 x 300 tests
Propoxyphene (PROX)
AU-416
2 x 625 tests
CRP hs
AU-645
3 x 100 tests
6-Acetylmorphine (6AM)
AU-425
2 x 600 tests
Cystatin-C
AU-691
2 x 100 tests
DBIL
AU-229
3 x 200 tests
ISE Reagents
Item #
Description
Ferritin
AU-694
3 x 100 tests
Buffer
AUH1011
4 x 2000 mL
Fructosamine w/cal
AU-612
3 x 80 tests
Cleaning Solution
AUH1019
4 x 100 mL
GGT
AU-209
3 x 300 tests
High Serum Standard
AUH1015
4 x 100 mL
GLU
AU-208
3 x 250 tests
Low/High Urine Standard
AUH1016
4 x 100 mL
HbA1c w/Lyse
AU-300
1 x 200 tests
Low Serum Standard
AUH1014
4 x 100 mL
HDLD w/cal
AU-616
3 x 250 tests
Mid Standard
AUH1012
4 x 2000 mL
Homocysteine w/cal
AU-201
1 x 150 tests
Na/K Selectivity Ck Solution
AUH1018
2 x 25 mL
Homocysteine w/cal Axis Shield
AS-201
1 x 150 tests
Reference
AUH1013
4 x 1000 mL
Insulin
AU-614
1 x 200 tests
Wash Concentrate
CC160
2000 mL
Iron w/cal
AU-618
3 x 200 tests
LDH
AU-205
3 x 300 tests
LDLD w/cal
AU-661
3 x 250 tests
Lipase w/cal
AU-621
3 x 100 tests
Lithium w/cal
AU-654
1 x 200 tests
Lp(a)
AU-204
3 x 400 tests
Microalbumin
AU-662
2 x 100 tests
Service
MG
AU-220
3 x 200 tests
PO4
AU-218
3 x 200 tests
Rheumatoid Factor
AU-629
3 x 100 tests
AU400 and AU640 chemistry analyzers include one-year service agreement with annual PM, parts, labor, and hotline support
TBIL
AU-228
3 x 300 tests
TIBC (direct)
AU-659
3 x 100 tests
TP
AU-217
3 x 250 tests
Transferrin
AU-641
3 x 100 tests
TG
AU-213
3 x 250 tests
URIC
AU-212
3 x 300 tests
Instruments Refurbished AU400 and AU640 chemistry analyzers with one-year warranty include installation and training.
Wake Forest Biotech Place 575 N. Patterson Avenue, Suite 430 Winston-Salem, NC 27101 800-471-7272 or 336-722-8910 • fax 336-722-8915