Skip to main content

Review of Environmental Factors - Camden Valley Way Upgrade and Liz Kernohan Drive Extension (Final)

Page 1

APPENDIX A:

Proposed Development Plans

17/0065 – Revised REF: Camden Valley Way Upgrade Works

Appendix


CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION DETAILED DESIGN AY

N MDE

YW LLE

VA

CA

LIZ RW

RN KE

RW RW

OH

RW

IVE DR AN

LOCALITY PLAN NOT TO SCALE

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

COVER SHEET

Drawn

Date

Scale

JER

MAR 2023

N.T.S

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C101-001

B

Mar 06, 2024 - 9:09am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C101-00.dwg

RW


DRAWING INDEX C106-133 C106-134 C106-141 C106-151 C106-161 C106-201 C106-202 C106-203 C106-204 C106-205 C106-206 C106-207 C106-301 C106-302 C106-303 C106-304 C106-305 C106-306 C106-307 C106-308 C106-309 C106-310 C106-311 C106-312 C106-340 C106-341 C106-351 C106-352 C106-353 C106-354 C106-361 C106-362 C106-363 C106-364 C106-365 C106-366 C106-367 C106-368 C106-369 C106-370 C106-371 C106-372 C106-373 C106-381 C106-391 C106-401 C106-402 C106-403 C106-411 C106-412 C106-413 C106-414 C106-415 C106-416 C106-417 C106-501 C106-511 C106-601 C106-701 C107-001 C107-002 C107-003 C107-004 C107-005 C107-006 C107-007 C107-008 C107-009 C108-001

ROAD LONGITUDINAL SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 3 ROAD LONGITUDINAL SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 4 ROAD LONGITUDINAL SECTIONS - RHEINBERGERS CIRCUIT - MC01 - SHEET 1 ROAD LONGITUDINAL SECTIONS - GRIMES AVENUE - MC02 - SHEET 1 PATH LONGITUDINAL SECTIONS - PATH (MP11), (MP12) AND (MP31) TYPICAL ROAD CROSS SECTIONS - SHEET 1 TYPICAL ROAD CROSS SECTIONS - SHEET 2 TYPICAL ROAD CROSS SECTIONS - SHEET 3 TYPICAL ROAD CROSS SECTIONS - SHEET 4 TYPICAL ROAD CROSS SECTIONS - SHEET 5 TYPICAL ROAD CROSS SECTIONS - SHEET 6 TYPICAL ROAD CROSS SECTIONS - SHEET 7 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 1 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 2 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 3 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 4 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 5 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 6 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 7 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 8 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 9 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 10 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 11 ROAD CROSS SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 12 ROAD CROSS SECTIONS - HILDER STREET - MC03 - SHEET 1 ROAD CROSS SECTIONS - HILDER STREET - MC03 - SHEET 2 ROAD CROSS SECTIONS - KIRKHAM LANE - MCA2 - SHEET 1 ROAD CROSS SECTIONS - KIRKHAM LANE - MCA2 - SHEET 2 ROAD CROSS SECTIONS - KIRKHAM LANE - MCA2 - SHEET 3 ROAD CROSS SECTIONS - KIRKHAM LANE - MCA2 - SHEET 4 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 1 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 2 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 3 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 4 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 5 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 6 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 7 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 8 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 9 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 10 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 11 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 12 ROAD CROSS SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 13 ROAD CROSS SECTIONS - RHEINBERGERS CIRCUIT - MC01 - SHEET 1 ROAD CROSS SECTIONS - GRIMES AVENUE - MC02 - SHEET 1 KERB RETURN ALIGNMENT PLAN - SHEET 1 KERB RETURN ALIGNMENT PLAN - SHEET 2 KERB RETURN ALIGNMENT PLAN - SHEET 3 KERB RETURN ALIGNMENT PROFILES - SHEET 1 KERB RETURN ALIGNMENT PROFILES - SHEET 2 KERB RETURN ALIGNMENT PROFILES - SHEET 3 KERB RETURN ALIGNMENT PROFILES - SHEET 4 KERB RETURN ALIGNMENT PROFILES - SHEET 5 KERB RETURN ALIGNMENT PROFILES - SHEET 6 KERB RETURN ALIGNMENT PROFILES - SHEET 7 ROUNDABOUT CENTRAL ISLAND - JOINTING PLAN ROUNDABOUT AND SPLITTER ISLAND DETAILS DRIVEWAY (MD01) AND (MD02) - PLAN AND PROFILES TCS PLINTH DETAIL LAND ACQUISTION PLAN - SHEET 1 LAND ACQUISTION PLAN - SHEET 2 LAND ACQUISTION PLAN - SHEET 3 LAND ACQUISTION PLAN - SHEET 4 LAND ACQUISTION PLAN - SHEET 5 LAND ACQUISTION PLAN - SHEET 6 LAND ACQUISTION PLAN - SHEET 7 LAND ACQUISTION PLAN - SHEET 8 LAND ACQUISTION PLAN - SHEET 9 STORMWATER MANAGEMENT PLAN - SHEET 1

C108-002 C108-003 C108-004 C108-005 C108-006 C108-007 C108-008 C108-009 C108-101 C108-102 C108-103 C108-104 C108-105 C108-106 C108-107 C108-201 C108-301 C108-302 C108-303 C108-304 C108-305 C108-306 C108-307 C108-308 C108-401 C108-402 C108-403 C108-404 C108-405 C108-406 C108-407 C108-408 C108-409 C108-501 C108-502 C108-511 C108-512 C108-620 C109-001 C109-002 C109-003 C109-004 C109-005 C109-006 C109-007 C109-008 C109-009 C109-101 C109-301 C109-302 C110-001 C110-002 C110-101 C110-102 C110-103 C110-201 C110-202 C110-203 C111-001 C111-002 C111-003 C111-004 C111-005 C111-006 C111-007 C111-008 C111-009 C111-101 C112-001

STORMWATER MANAGEMENT PLAN - SHEET 2 STORMWATER MANAGEMENT PLAN - SHEET 3 STORMWATER MANAGEMENT PLAN - SHEET 4 STORMWATER MANAGEMENT PLAN - SHEET 5 STORMWATER MANAGEMENT PLAN - SHEET 6 STORMWATER MANAGEMENT PLAN - SHEET 7 STORMWATER MANAGEMENT PLAN - SHEET 8 STORMWATER MANAGEMENT PLAN - SHEET 9 STORMWATER LONGITUDINAL SECTIONS - SHEET 1 STORMWATER LONGITUDINAL SECTIONS - SHEET 2 STORMWATER LONGITUDINAL SECTIONS - SHEET 3 STORMWATER LONGITUDINAL SECTIONS - SHEET 4 STORMWATER LONGITUDINAL SECTIONS - SHEET 5 STORMWATER LONGITUDINAL SECTIONS - SHEET 6 STORMWATER LONGITUDINAL SECTIONS - SHEET 7 STORMWATER SETOUT AND SCHEDULES STORMWATER CULVERT 1 DETAILS STORMWATER CULVERT 2 DETAILS STORMWATER CULVERT 3 DETAILS STORMWATER CULVERT 4 DETAILS CULVERT SLAB JOINTING LAYOUT CULVERT SLAB JOINTING DETAILS STORMWATER DETAILS - SHEET 1 STORMWATER DETAILS - SHEET 2 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 1 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 2 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 3 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 4 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 5 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 6 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 7 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 8 STORMWATER MANAGEMENT CATCHMENT PLAN - SHEET 9 STORMWATER MANAGEMENT CALCULATIONS 10% AEP - SHEET 1 STORMWATER MANAGEMENT CALCULATIONS 10% AEP - SHEET 2 STORMWATER MANAGEMENT CALCULATIONS 1% AEP - SHEET 1 STORMWATER MANAGEMENT CALCULATIONS 1% AEP - SHEET 2 STORMWATER BASIN NOTES AND DETAILS PAVEMENT PLANS - SHEET 1 PAVEMENT PLANS - SHEET 2 PAVEMENT PLANS - SHEET 3 PAVEMENT PLANS - SHEET 4 PAVEMENT PLANS - SHEET 5 PAVEMENT PLANS - SHEET 6 PAVEMENT PLANS - SHEET 7 PAVEMENT PLANS - SHEET 8 PAVEMENT PLANS - SHEET 9 PAVEMENT SUBSOIL DRAINAGE PLANS - SHEET 1 PAVEMENT DETAILS - SHEET 1 PAVEMENT DETAILS - SHEET 2 RETAINING WALL PLAN - SHEET 1 RETAINING WALL PLAN - SHEET 2 RETAINING WALLS ELEVATIONS (MW01) - SHEET 1 RETAINING WALLS ELEVATIONS (MW01) - SHEET 2 RETAINING WALLS ELEVATIONS (MW02) AND (MW03) - SHEET 2 RETAINING WALL NOTES AND DETAILS - SHEET 1 RETAINING WALL NOTES AND DETAILS - SHEET 2 RETAINING WALL NOTES AND DETAILS - SHEET 3 PAVEMENT MARKING AND SIGNPOSTING - SHEET 1 PAVEMENT MARKING AND SIGNPOSTING - SHEET 2 PAVEMENT MARKING AND SIGNPOSTING - SHEET 3 PAVEMENT MARKING AND SIGNPOSTING - SHEET 4 PAVEMENT MARKING AND SIGNPOSTING - SHEET 5 PAVEMENT MARKING AND SIGNPOSTING - SHEET 6 PAVEMENT MARKING AND SIGNPOSTING - SHEET 7 PAVEMENT MARKING AND SIGNPOSTING - SHEET 8 PAVEMENT MARKING AND SIGNPOSTING - SHEET 9 PAVEMENT MARKING AND SIGNPOSTING SETOUT AND SCHEDULES - SHEET 1 EXISTING UTILITIES PLAN - SHEET 1

C112-002 C112-003 C112-004 C112-005 C112-006 C112-007 C112-008 C112-009 C112-011 C112-012 C112-013 C112-014 C112-015 C112-021 C112-022 C112-023 C112-024 C112-025 C112-031 C112-032 C112-033 C112-034 C112-035 C112-036 C112-037 C112-038 C112-039 C112-041 C112-042 C112-043 C112-044 C112-045 C112-046 C112-047 C112-048 C112-049 C112-101 C112-102 C112-103 C112-104 C112-105 C112-106 C112-107 C112-108 C112-109 C115-001 C115-002 C115-003 C115-004 C115-005 C115-006 C115-007 C115-008 C115-009 C116-001 C116-002 C116-003 C116-004 C116-005 C116-006 C116-007 C116-008 C116-101 C116-102 C116-103 C116-104 C116-105 C117-001 C117-002

EXISTING UTILITIES PLAN - SHEET 2 EXISTING UTILITIES PLAN - SHEET 3 EXISTING UTILITIES PLAN - SHEET 4 EXISTING UTILITIES PLAN - SHEET 5 EXISTING UTILITIES PLAN - SHEET 6 EXISTING UTILITIES PLAN - SHEET 7 EXISTING UTILITIES PLAN - SHEET 8 EXISTING UTILITIES PLAN - SHEET 9 SEWER MAIN CONTROL PLANS - SHEET 1 SEWER MAIN CONTROL PLANS - SHEET 2 SEWER MAIN CONTROL PLANS - SHEET 3 SEWER MAIN CONTROL PLANS - SHEET 4 SEWER MAIN CONTROL PLANS - SHEET 5 WATER MAIN CONTROL PLANS - SHEET 1 WATER MAIN CONTROL PLANS - SHEET 2 WATER MAIN CONTROL PLANS - SHEET 3 WATER MAIN CONTROL PLANS - SHEET 4 WATER MAIN CONTROL PLANS - SHEET 5 SEWER LONGITUDINAL SECTIONS - SHEET 1 SEWER LONGITUDINAL SECTIONS - SHEET 2 SEWER LONGITUDINAL SECTIONS - SHEET 3 SEWER LONGITUDINAL SECTIONS - SHEET 4 SEWER LONGITUDINAL SECTIONS - SHEET 5 SEWER LONGITUDINAL SECTIONS - SHEET 6 SEWER LONGITUDINAL SECTIONS - SHEET 7 SEWER LONGITUDINAL SECTIONS - SHEET 8 SEWER LONGITUDINAL SECTIONS - SHEET 9 WATER LONGITUDINAL SECTIONS - SHEET 1 WATER LONGITUDINAL SECTIONS - SHEET 2 WATER LONGITUDINAL SECTIONS - SHEET 3 WATER LONGITUDINAL SECTIONS - SHEET 4 WATER LONGITUDINAL SECTIONS - SHEET 5 WATER LONGITUDINAL SECTIONS - SHEET 6 WATER LONGITUDINAL SECTIONS - SHEET 7 WATER LONGITUDINAL SECTIONS - SHEET 8 WATER LONGITUDINAL SECTIONS - SHEET 9 INTEGRATED UTILITIES PLAN - SHEET 1 INTEGRATED UTILITIES PLAN - SHEET 2 INTEGRATED UTILITIES PLAN - SHEET 3 INTEGRATED UTILITIES PLAN - SHEET 4 INTEGRATED UTILITIES PLAN - SHEET 5 INTEGRATED UTILITIES PLAN - SHEET 6 INTEGRATED UTILITIES PLAN - SHEET 7 INTEGRATED UTILITIES PLAN - SHEET 8 INTEGRATED UTILITIES PLAN - SHEET 9 CONSTRUCTION STAGING PLAN - SHEET 1 CONSTRUCTION STAGING PLAN - SHEET 2 CONSTRUCTION STAGING PLAN - SHEET 3 CONSTRUCTION STAGING PLAN - SHEET 4 CONSTRUCTION STAGING PLAN - SHEET 5 CONSTRUCTION STAGING PLAN - SHEET 6 CONSTRUCTION STAGING PLAN - SHEET 7 CONSTRUCTION STAGING PLAN - SHEET 8 CONSTRUCTION STAGING PLAN - SHEET 9 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 1 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 2 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 3 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 4 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 5 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 6 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 7 VEHICLE SWEPT PATHS - DESIGN VEHICLE - SHEET 8 VEHICLE SWEPT PATHS - CHECK VEHICLE - SHEET 1 VEHICLE SWEPT PATHS - CHECK VEHICLE - SHEET 2 VEHICLE SWEPT PATHS - CHECK VEHICLE - SHEET 3 VEHICLE SWEPT PATHS - CHECK VEHICLE - SHEET 4 VEHICLE SWEPT PATHS - CHECK VEHICLE - SHEET 5 ALIGNMENT SETOUT TABLES - SHEET 1 ALIGNMENT SETOUT TABLES - SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C101-00.dwg

COVER SHEET DRAWING INDEX CONSTRUCTION NOTES - SHEET 1 CONSTRUCTION NOTES - SHEET 2 KEY PLAN DEMOLITION PLANS - SHEET 1 DEMOLITION PLANS - SHEET 2 DEMOLITION PLANS - SHEET 3 DEMOLITION PLANS - SHEET 4 DEMOLITION PLANS - SHEET 5 DEMOLITION PLANS - SHEET 6 DEMOLITION PLANS - SHEET 7 DEMOLITION PLANS - SHEET 8 DEMOLITION PLANS - SHEET 9 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 1 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 2 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 3 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 4 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 5 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 6 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 7 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 8 SOIL EROSION AND SEDIMENT CONTROL PLANS - SHEET 9 SOIL EROSION AND SEDIMENT CONTROL NOTES - SHEET 1 SOIL EROSION AND SEDIMENT CONTROL DETAILS - SHEET 1 SOIL EROSION AND SEDIMENT CONTROL DETAILS - SHEET 2 BULK EARTHWORKS PLANS - SHEET 1 BULK EARTHWORKS PLANS - SHEET 2 BULK EARTHWORKS PLANS - SHEET 3 BULK EARTHWORKS PLANS - SHEET 4 BULK EARTHWORKS PLANS - SHEET 5 BULK EARTHWORKS PLANS - SHEET 6 BULK EARTHWORKS PLANS - SHEET 7 BULK EARTHWORKS PLANS - SHEET 8 BULK EARTHWORKS PLANS - SHEET 9 EARTHWORKS SECTIONS PLAN EARTHWORKS SECTIONS GENERAL ARRANGEMENT PLAN - SHEET 1 GENERAL ARRANGEMENT PLAN - SHEET 2 GENERAL ARRANGEMENT PLAN - SHEET 3 GENERAL ARRANGEMENT PLAN - SHEET 4 GENERAL ARRANGEMENT PLAN - SHEET 5 GENERAL ARRANGEMENT PLAN - SHEET 6 GENERAL ARRANGEMENT PLAN - SHEET 7 GENERAL ARRANGEMENT PLAN - SHEET 8 GENERAL ARRANGEMENT PLAN - SHEET 9 ALIGNMENT CONTROL PLAN - SHEET 1 ALIGNMENT CONTROL PLAN - SHEET 2 ALIGNMENT CONTROL PLAN - SHEET 3 ALIGNMENT CONTROL PLAN - SHEET 4 ALIGNMENT CONTROL PLAN - SHEET 5 ALIGNMENT CONTROL PLAN - SHEET 6 ALIGNMENT CONTROL PLAN - SHEET 7 ALIGNMENT CONTROL PLAN - SHEET 8 ALIGNMENT CONTROL PLAN - SHEET 9 MEDIAN CONTROL PLAN - SHEET 1 MEDIAN CONTROL PLAN - SHEET 2 MEDIAN CONTROL PLAN - SHEET 3 MEDIAN CONTROL PLAN - SHEET 4 MEDIAN CONTROL PLAN - SHEET 5 MEDIAN CONTROL PLAN - SHEET 6 ROAD LONGITUDINAL SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 1 ROAD LONGITUDINAL SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 2 ROAD LONGITUDINAL SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 3 ROAD LONGITUDINAL SECTIONS - CAMDEN VALLEY WAY - MCB1 - SHEET 4 ROAD LONGITUDINAL SECTIONS - HILDER STREET - MC03 - SHEET 1 ROAD LONGITUDINAL SECTIONS - KIRKHAM LANE - MCA2 - SHEET 1 ROAD LONGITUDINAL SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 1 ROAD LONGITUDINAL SECTIONS - LIZ KERNOHAN DRIVE - MCA1 - SHEET 2

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DRAWING INDEX

Drawn

Date

Scale

JER

MAR 2023

N.T.S

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C101-002

B

Mar 06, 2024 - 9:09am

C101-001 C101-002 C101-101 C101-102 C102-001 C102-201 C102-202 C102-203 C102-204 C102-205 C102-206 C102-207 C102-208 C102-209 C103-001 C103-002 C103-003 C103-004 C103-005 C103-006 C103-007 C103-008 C103-009 C103-101 C103-102 C103-103 C104-001 C104-002 C104-003 C104-004 C104-005 C104-006 C104-007 C104-008 C104-009 C104-101 C104-201 C105-001 C105-002 C105-003 C105-004 C105-005 C105-006 C105-007 C105-008 C105-009 C106-001 C106-002 C106-003 C106-004 C106-005 C106-006 C106-007 C106-008 C106-009 C106-021 C106-022 C106-023 C106-024 C106-025 C106-026 C106-101 C106-102 C106-103 C106-104 C106-111 C106-121 C106-131 C106-132


THE DRAWING DIMENSIONS SHALL NOT BE OBTAINED BY SCALING.

2.

THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE SPECIFICATION AND WRITTEN INSTRUCTIONS. ANY DISCREPANCY OR VARIATION SHALL BE REFERRED TO THE SUPERINTENDENT BEFORE PROCEEDING WITH THE WORK.

3.

4.

5.

6.

7.

8.

1.

2.

ALL WORK TO BE IN ACCORDANCE WITH CAMDEN COUNCIL ENGINEERING REQUIREMENTS FOR DEVELOPMENT, CAMDEN COUNCIL ENGINEERING CONSTRUCTION SPECIFICATION, AND CAMDEN COUNCIL STANDARD DRAWINGS. NO ADDITIONAL OR P.C. WORKS SHALL BE UNDERTAKEN WITHOUT THE SUPERINTENDENTS APPROVAL. CONFIRM COUNCIL INSTRUCTIONS WITH SUPERINTENDENT.

THE CONTRACTOR HAS SOLE RESPONSIBILITY TO EXERCISE CARE AND TAKE PRECAUTIONS TO ENSURE CONSTRUCTION ACTIVITIES DO NOT AFFECT ADJACENT PROPERTIES, ACCESS OR STRUCTURES. MAINTAIN EMBANKMENTS AND STRUCTURES IN STABLE CONDITION DURING CONSTRUCTION ENSURING NO PART IS OVERSTRESSED. TEMPORARY STRUCTURES, FORMWORK, TEMPORARY BRACING, SHORING AND THE LIKE SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. THE CONTRACTOR WILL BE RESPONSIBLE FOR THE FULL QA DOCUMENTATION OF THE PROJECT TO ENSURE WORKS MEET THE RELEVANT SECTIONS OF AUSPEC FOR ROADS, DRAINAGE, WATER AND SEWER. A COMPLETE ITP PLAN SHALL BE SUBMITTED TO THE SUPERINTENDENT FOR APPROVAL PRIOR TO WORKS COMMENCING ON SITE.

PVC-U PIPEWORK INSTALLATION TO AS 2566 AND MANUFACTURER'S STANDARDS AND SPECIFICATIONS.

4.

RCP PIPE BEDDING SHALL BE (U.N.O.) TYPE HS2, IN ACCORDANCE WITH CURRENT RELEVANT AUSTRALIAN STANDARDS.

5.

PVC-U PIPE BEDDING SHALL BE IN ACCORDANCE WITH AS 2566 AND MANUFACTURER'S STANDARDS AND SPECIFICATIONS.

6.

MINIMUM GRADE TO STORMWATER LINES TO BE 1% (U.N.O.).

7.

CONTRACTOR TO SUPPLY AND INSTALL ALL FITTINGS AND SPECIALS INCLUDING VARIOUS PIPE ADAPTORS TO ENSURE PROPER CONNECTION BETWEEN DISSIMILAR PIPEWORK.

8.

ALL PIPE JUNCTIONS UP TO AND INCLUDING 450 DIA. AND TAPERS SHALL BE VIA PURPOSE MADE FITTINGS.

9.

ALL CONNECTIONS TO EXISTING DRAINAGE PITS SHALL BE MADE IN A TRADESMAN-LIKE MANNER AND THE INTERNAL WALL OF THE PIT AT THE POINT OF ENTRY SHALL BE CEMENT RENDERED TO ENSURE A SMOOTH FINISH.

10.

11. 9.

10.

CONTRACTOR IS TO VERIFY THE LOCATION OF ALL SERVICES WITH EACH RELEVANT AUTHORITY. ANY DAMAGE TO SERVICES SHALL BE REPAIRED BY THE CONTRACTOR OR THE RELEVANT AUTHORITY AT THE CONTRACTOR'S EXPENSE. SERVICES SHOWN ON THESE PLANS ARE ONLY THOSE EVIDENT AT THE TIME OF SURVEY.

12.

13.

UNDERTAKE WORKS TO PRINCIPLES OF AS 9001. SUBMIT WORK METHOD STATEMENT TO SUPERINTENDENT.

15.

16.

17.

18.

19.

ENSURE ADEQUATE TRENCH FOUNDATION AND BEDDING COMPACTION SPECIFICALLY ADJACENT TO DRAINAGE STRUCTURES AND PROTECTION TO PIPES FROM CONSTRUCTION TRAFFIC. CRACKED STORMWATER PIPES WILL NOT BE ACCEPTED.

15.

ALL PITS DEEPER THAN 0.9m BUT LESS THAN 1.2m TO BE MINIMUM INTERNAL WIDTH 600 x 900 UNO. ALL PITS DEEPER THAN 1.2m TO BE MINIMUM INTERNAL WIDTH 900SQ UNO AND ARE TO BE CONSTRUCTED WITH STEP IRONS IN ACCORDANCE WITH AS 1657 AND DETAILS.

CONTRACTOR TO PROVIDE ALL SURVEY SETOUT, AND WAE FROM DATA. REFER SURVEY INFORMATION BY INFOCUS SURVEYORS REF No: 13945-13096.02 DATED: JUNE 2022

WHERE DEPTH OF PIT EXCEEDS 1500, WALLS AND BOTTOM TO BE REINFORCED IN ALL DIRECTIONS WITH SL82 MESH AT 40 COVER TO INSIDE FACE WITH N12 CORNER BARS 300 LEGS AT 400 CTRS. PITS DEEPER THAN 2000 SHALL BE DESIGNED BY A PROFESSIONAL STRUCTURAL ENGINEER.

ALL LEVELS SHALL BE OBTAINED FROM ESTABLISHED BENCH MARKS ONLY. STANDARD DATUM FOR ALL DRAWINGS IS AUSTRALIAN HEIGHT DATUM (A.H.D.). STANDARD PROJECTION FOR ALL DRAWINGS IS GDA2020.

- ROCK SIZE 300-600mm NOM DIAMETER, HARD DURABLE STONE. - GEOTEXTILE BIDIM A34 OR EQUAL KEYED 300mm EACH END AND INSTALLED TO MANUFACTURERS SPECIFICATION.

A TRAFFIC CONTROL PLAN TO AS 1742.3 IS TO BE SUBMITTED TO COUNCIL FOR APPROVAL PRIOR TO WORKS COMMENCING. 1.

PROPOSED SERVICES CROSSING EXISTING ROADS SHALL BE THRUST BORED UNDER THE ROAD SO AS NOT TO DAMAGE EXISTING SURFACES.

2.

SCOUR PROTECTION, SUB SOIL DRAINAGE AND UNSUITABLE SUB-GRADE REPLACEMENT SHALL BE AT THE DIRECTION OF THE SUPERINTENDENT.

3.

NO TREES ARE TO BE REMOVED OR LOPPED OTHER THAN THOSE SHOWN AND THOSE IN ROAD RESERVES AND AREAS WITHIN LOTS SUBJECT TO CUT & FILL, WITHOUT COUNCILS WRITTEN PERMISSION. A TREE INSPECTION WITH COUNCIL SHALL BE ARRANGED ONCE LOTS HAVE BEEN PEGGED.

4.

ALL NEW WORKS ARE TO MAKE SMOOTH JUNCTIONS WITH ALL EXISTING CONDITIONS. AC JOINTS TO BE SAW CUT AT CONNECTION TO EXISTING PAVEMENT. THE CONTRACTOR IS TO MAKE ALL DUE ALLOWANCES FOR WORKS DURING CONSTRUCTION.

5.

THE CONTRACTOR SHALL ALLOW FOR THE CAPPING OFF, EXCAVATION, REMOVAL AND DISPOSAL IF REQUIRED OF ALL EXISTING SERVICES IN AREAS AFFECTED BY WORKS WITHIN THE CONTRACT AREA AS DIRECTED OTHERWISE BY THE SUPERINTENDENT.

EXISTING BUILDINGS, EXTERNAL STRUCTURES, AND TREES SHOWN ON THESE DRAWINGS ARE FEATURES EXISTING PRIOR TO ANY DEMOLITION WORKS. CONTRACTOR SHALL CONSTRUCT TEMPORARY SERVICES TO MAINTAIN EXISTING SUPPLY TO BUILDINGS REMAINING IN OPERATION DURING WORKS TO THE SATISFACTION AND APPROVAL OF THE SUPERINTENDENT. ONCE DIVERSION IS COMPLETE AND COMMISSIONED THE CONTRACTOR SHALL REMOVE ALL SUCH TEMPORARY SERVICES AND MAKE GOOD TO THE SATISFACTION OF THE SUPERINTENDENT.

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

-1

Description 0

1cm at full size

10cm

PAVEMENT MARKING SHALL BE SPOTTED OUT AND APPROVED PRIOR TO SPRAYING.

3.

EXISTING PAVEMENT MARKING IN CONFLICT WITH NEW WORKS SHALL BE REMOVED IN ACCORDANCE WITH AS 1742.2. REDUNDANT PAVEMENT PARKING MUST BE REMOVED BY GRINDING, BLASTING OR RESURFACING. PAINTING OVER WITH BLACK BITUMINOUS PAINT IS NOT ACCEPTABLE.

4.

RAISED PAVEMENT MARKERS ARE TO BE INSTALLED IN ACCORDANCE WITH AS 1742.2 AND AS DIRECTED BY SUPERINTENDENT.

5.

SIGNAGE SHALL BE IN ACCORDANCE WITH AS 1742.1, AS 1742.2, AS 2890.1 AND THE RELEVANT LOCAL AND STATE AUTHORITY GUIDELINES AND SPECIFICATIONS.

6.

EXISTING SIGNAGE IN CONFLICT WITH NEW WORKS SHALL BE REMOVED OR RELOCATED AS DIRECTED BY THE SUPERINTENDENT.

THE CONTROL TESTING OF EARTHWORKS SHALL BE IN ACCORDANCE WITH THE GUIDELINES IN AS 3798. WHERE IT IS PROPOSED TO USE TEST METHOD AS 1289 EB.1 OR AS 1289 EB.2 TO DETERMINE THE FIELD DENSITY, A SAND REPLACEMENT METHOD SHALL BE USED TO CONFIRM THE RESULTS AS DIRECTED.

7.

TO ELIMINATE EXCESSIVE GLARE FROM THE SURFACE OF A SIGN IT SHOULD BE TURNED APPROXIMATELY 5° AWAY FROM THE NORMAL

8.

ALL SIGNAGE TO BE CLEAR OF ALL VEGETATION AND OBSTRUCTIONS.

9.

EARTHWORKS, PREPARATIONS, SUB-GRADE CBR AND PAVEMENT THICKNESSES TO BE CONFIRMED BY GEOTECHNICAL ENGINEER. SUBMIT GEOTECHNICAL ENGINEER'S CERTIFICATE OF WORKS ON COMPLETION.

9.

CONDITION ASSESSMENT TO BE UNDERTAKEN ON ALL EXISTING SIGN FACES TO BE RELOCATED PRIOR TO BEING REUSED IN ACCORDANCE WITH RELEVANT SPECIFICATIONS AND STANDARDS AS DIRECTED BY PRINCIPAL.

10.

REFER GEOTECHNICAL REPORT BY: MM GEOMECHANICS REF No: MMGEO2021AC_AF REVISION C DATED: 20 FEB 2022

10.

ALL EXISTING LINEMARKING AND SIGNPOSTING AFFECTED BY THE NEW WORKS AND NOT OTHERWISE CONFLICTING WITH PROPOSED LINEMARKING IS TO BE REINSTATED.

11.

WHERE THE SLOPE OF THE NATURAL SURFACE EXCEEDS ONE IN FOUR (1V:4H) BENCHES ARE TO BE CUT TO PREVENT SLIPPING OF THE PLACED FILL MATERIAL AS REQUIRED BY THE GEOTECHNICAL ENGINEER TO STANDARD PRACTICE.

11.

ALL LINEMARKING TO BE THERMOPLASTIC IN ACCORDANCE WITH SPECIFICATION R145.

12.

REFER TFNSW DELINEATION GUIDE AND R145 FOR PAVEMENT MARKING NOTATION.

4.

20cm

REMOVE TOPSOIL, SLOPEWASH & DELETERIOUS MATERIAL. GEOTECHNICAL ENGINEER TO CONFIRM SPOIL & UNSUITABLE.

5.

EXCAVATED MATERIAL SHALL BE SELECTED TO PLACE BETTER QUALITY AT FILL SUBGRADES. REPLACEMENT OF CUT SUB-GRADES MAY BE INSTRUCTED BY THE SUPERINTENDENT AS EARTHWORKS OPERATION.

6.

IN-SITU DENSITY TESTS ARE TO BE CARRIED OUT ON ALL SIGNIFICANT FILLS, ROAD SUB-GRADES AND PAVEMENT COURSES AS DIRECTED BY THE SUPERINTENDENT. BENKELMAN BEAM TEST PAVEMENT BASECOURSE. ALL TESTS ARE TO BE CARRIED OUT BY A REGISTERED N.A.T.A. GEOTECHNICAL LABORATORY.

7.

12.

LOTS REQUIRING FILL SHALL BE CONSTRUCTED TO LEVEL 1 SUPERVISION WITH TESTING AND DOCUMENTATION SUITABLE TO DETERMINE FUTURE LOT CLASSIFICATION.

ALL BATTERS ARE TO BE SCARIFIED TO ASSIST WITH ADHESION OF TOP SOIL TO BATTER FACE.

13.

NO MATERIALS TO BE STOCKPILED ON FUTURE ALLOTMENTS WITHOUT APPROVAL IN WRITING FROM THE SUPERINTENDENT.

14.

REMOVE EXCESS SPOIL AND DEMOLISHED MATERIAL FROM SITE TO LOCATION AND DETAIL DETERMINED BY THE CONTRACTOR. AT CONTRACTORS COST.

15.

PAVEMENT BASE COURSE SUBJECT TO BENKELMAN BEAM TEST AS REQUIRED.

16.

SUB-GRADE DEFLECTION SHALL BE CONFIRMED BY THE SUPERINTENDENT BY PROOF ROLL WITH A 10 TONNE OR HEAVIER DEAD WEIGHT ROLLER. SUB-GRADE REPLACEMENT MAY BE INSTRUCTED. RIP ROCK SUB-GRADE TO 300mm.

SAFETY IN DESIGN 1.

THE DESIGN SAFETY ASSESSMENT HAS BEEN CARRIED OUT WITH REFERENCE TO CURRENT WHS REGULATIONS FOR DESIGN TO BE SAFE SO FAR AS REASONABLY PRACTICABLE. HAZARD AND RISK IDENTIFICATION IS BASED ON INFORMATION AVAILABLE TO THE DESIGNER AT THE TIME OF THE DESIGN.

2.

ASSESSMENT IS LIMITED TO THE SCOPE OF ACOR'S COMMISSION INCLUDING: · EARTHWORKS · ROAD DESIGN · STORMWATER MANAGEMENT

3.

IDENTIFIED HAZARDS ARE THOSE WHICH ARE AFFECTED BY THE DESIGN, AND ARE WITHIN THE CONTROL OF THE DESIGNER.

17.

4.

HAZARDS AND RISK RELATING TO CONSTRUCTION, OPERATION, MAINTENANCE AND DEMOLITION MUST BE CONSIDERED BY THE OWNER, MANAGER, BUILDER, USER, MAINTAINER AND DEMOLISHER. ALL SUCH ENTITIES ARE ASSUMED TO BE QUALIFIED, COMPETENT AND EXPERIENCED.

5.

SEEK ADVICE WHERE ACTIVITIES ARE OUTSIDE THE FIELD OF EXPERIENCE OF THE OPERATOR/BUILDER/MAINTAINER, INCLUDING BUT NOT LIMITED TO QUALIFIED STRUCTURAL AND GEOTECHNICAL ENGINEERS.

6.

NO ATYPICAL HAZARDS HAVE BEEN IDENTIFIED IN THE DESIGN PROCESS.

7.

WHERE STATE OR TERRITORY LEGISLATION EXISTS, OR OTHERWISE AS MAY BE REQUIRED, A DESIGN VERIFICATION STATEMENT WILL BE PROVIDED BY THE CONSULTING ENGINEER.

PAVEMENT MATERIAL REQUIREMENTS: - A.C. IN ACCORDANCE TFNSW R116 AND TD00018:2021. - BASE COURSE - CRUSHED ROCK OR GRAVEL IN ACCORDANCE WITH TFNSW3051. SOAKED CBR (4 DAYS) 80% MIN, PI 2% MIN, 6% MAX. - SUB-BASE - CRUSHED ROCK OR GRAVEL IN ACCORDANCE WITH TFNSW3051. SOAKED CBR (4 DAYS) 30% MIN, PI 12% MAX. - SELECT MATERIAL ZONE TO TFNSW R44

18.

CBR REQUIREMENTS: - SUB-GRADE MIN CBR 3% (U.N.O). - SUB-GRADE REPLACEMENT MIN CBR 15%. - SELECT MATERIAL MIN CBR 30%. - GEOTECHNICAL ENGINEER TO CONFIRM AT BOX OUT.

INTERRUPTION TO SUPPLY OF EXISTING SERVICES SHALL BE DONE SO AS NOT TO CAUSE ANY INCONVENIENCE TO THE PRINCIPAL. CONTRACTOR TO GAIN APPROVAL OF SUPERINTENDENT FOR TIME OF INTERRUPTION. North

100% DETAIL DESIGN ISSUE FOR REVIEW

PAVEMENT MARKING AND SIGNAGE NOTES

2.

THE CONTRACTOR SHALL ENSURE THAT AT ALL TIMES SERVICES TO ALL BUILDINGS NOT AFFECTED BY THE WORKS ARE NOT DISRUPTED.

Client

B

- BASE COURSE MIN 98% MODIFIED (AS 1289 - 5.2.1). - SUB-BASE MIN 98% MODIFIED (AS 1289 - 5.2.1). - SUB-GRADE MIN 100% STD (AS 1289 - 5.1.1). - SELECT SUB-GRADE/SUB-GRADE REPLACEMENT MIN 100% STD (AS 1289 - 5.1.1). - FILL UP TO 0.5m BELOW SUB-GRADE MIN 95% STD (AS 1289 - 5.1.1). - MOISTURE CONTENT SUB-GRADE -3% TO 0% OF OPTIMAL MOISTURE CONTENT.

PAVEMENT MARKING AND SIGNPOSTING SHALL BE IN ACCORDANCE WITH AS 1742 AND THE RELEVANT LOCAL AND STATE AUTHORITY GUIDELINES AND SPECIFICATIONS.

EXISTING SERVICES AND FEATURES

SERVICE CONDUITS SHALL BE PLACED AS DIRECTED BY AUSGRID, NBN, JEMENA AND AS REQUIRED BY COUNCIL.

COMPACTION REQUIREMENTS:

1.

PLACED ROCK SCOUR PROTECTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

A SINGLE CONTINUOUS STRIP OF GRASS TURF SHALL BE PLACED BEHIND THE BACK OF ALL KERBS, PERIMETER OF ALL INLET PITS, EACH SIDE OF FOOTPAVING, FRONT OF LOT BOUNDARIES, DRAIN OUTLETS, TOP OF EXCAVATED BATTERS AND DIAGONALLY TO STEEP GRADES EXCEEDING 10% AND AS DIRECTED IMMEDIATELY AFTER THE COMPLETION OF FOOTPATH GRADING AND CONSTRUCTION OF PITS RESPECTIVELY. TURFING/LANDSCAPE GRASS SHALL ALSO BE PLACED TO THE FULL WIDTH OF SWALE DRAINS UPON COMPLETION.

19.

CARE TO BE TAKEN BY CONTRACTOR WHEN COMPACTING OVER BURIED PIPES.

ALL WORKS ARE TO BE SETOUT BY A REGISTERED SURVEYOR. 18.

14.

3.

PROVIDE 3.0m LENGTH OF 100 DIA. SUBSOIL DRAINAGE PIPE WRAPPED IN FILTER SOCK, AT UPSTREAM END OF EACH PIT.

ALL INLET PIT GRATINGS AND PRECAST INLETS SHALL BE CONSTRUCTED TO COUNCILS STANDARD DRAWINGS.

17.

13.

GRASS TO BE TO COUNCIL'S SPECIFICATION. GRASS/TURF TO BE MAINTAINED BY CONTRACTOR AT ALL TIMES INCLUDING PERIODS OF INSUFFICIENT RAIN AND REPLACED AS REQUIRED.

WHERE SUBSOIL DRAINAGE LINES PASS UNDER FLOOR SLABS AND VEHICULAR PAVEMENTS, UNSLOTTED PVC-U SEWER GRADE PIPE SHALL BE USED.

14.

16.

12.

PRECAST PITS SHALL NOT BE USED UNLESS WRITTEN APPROVAL IS OBTAINED FROM THE SUPERINTENDENT.

ALL DISTURBED AREAS SHALL BE 50-75mm TOPSOILED, GRASS SEEDED OR TURFED AND MULCHED AS SOON AS PRACTICABLE, AND BATTERS AND BERMS TREATED IMMEDIATELY AFTER CONSTRUCTION OF SEWERAGE AND STORMWATER. AREAS OF DISTURBANCE SHALL BE APPROVED BY THE SUPERINTENDENT. REFER EROSION AND SEDIMENT CONTROL PLAN.

2.

8.

HOLD POINTS SHALL APPLY TO: - APPROVAL OF WORK METHOD STATEMENT - APPROVAL OF TRAFFIC CONTROL PLAN - LOCATION OF INGROUND SERVICES - SETOUT OF EACH AREA OF WORKS - CERTIFICATION OF SUBGRADE - STORMWATER PIPEWORK PRIOR TO BACKFILL - CONDUITS PRIOR TO BACKFILL - WORK AS EXECUTED SURVEY - GEOTECHNICAL CERTIFICATION. 11.

1.

RCP PIPEWORK INSTALLATION TO AS 3725 AND MANUFACTURER'S STANDARDS AND SPECIFICATIONS.

3.

THE CONTRACTOR MUST ENSURE SUPERINTENDENT AND/OR COUNCIL APPROVAL OF MATERIALS, PRIOR TO DELIVERY TO SITE. DIVERSION OF WATER AND THE PROTECTION OF WORKS IS THE CONTRACTORS RESPONSIBILITY.

ALL RCP PIPES SHALL BE CLASS "4" WITH RUBBER RING JOINTS (U.N.O.). ALL PVC-U PIPES SHALL BE CLASS "SN8" WITH RUBBER RING JOINTS OR SOLVENT WELDED (U.N.O.).

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C101-10.dwg

1.

EARTHWORKS AND PAVEMENT NOTES CONT.

EARTHWORKS AND PAVEMENT NOTES

STORMWATER NOTES

NOT FOR CONSTRUCTION ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

CONSTRUCTION NOTES SHEET 1 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C101-101

B

Mar 06, 2024 - 9:09am

GENERAL NOTES


FOUNDATIONS

REINFORCEMENT CONT' R5.

COVER TO REINFORCEMENT - CLEAR COVER TO ALL REINFORCEMENT FOR DURABILITY SHALL BE AS INDICATED IN THE CONCRETE NOTES. COVER SHALL NOT BE LESS THAN THE SIZE OF THE AGGREGATE OR THE MAIN BAR. PIPES OR CONDUITS SHALL NOT BE PLACED WITHIN THE COVER TO REINFORCEMENT.

FOOTINGS HAVE BEEN DESIGNED FOR AN ALLOWABLE BEARING INTENSITY OF 150kPa kPa ON NATURAL IN-SITU MATERIAL.

C9.

SIZES OF CONCRETE ELEMENTS DO NOT INCLUDE THICKNESS OF APPLIED FINISHES.

IF A GEOTECHNICAL INVESTIGATION HAS NOT BEEN MADE, THE FOUNDATION CONDITIONS AND REACTIVITY CLASS ARE AN ASSUMPTION AND MUST BE CONFIRMED BY TRIAL EXCAVATIONS BY THE BUILDER.

C10.

NO HOLES, CHASES OR EMBEDMENT OF PIPES OTHER THAN THOSE SHOWN ON THE STRUCTURAL DRAWINGS SHALL BE MADE IN CONCRETE MEMBERS WITHOUT PRIOR APPROVAL OF THE ENGINEER.

FOUNDATION MATERIAL SHALL BE APPROVED FOR THIS BEARING PRESSURE BEFORE PLACING MEMBRANE, REINFORCEMENT OR CONCRETE.

C11.

CONSTRUCTION JOINTS SHALL BE PROPERLY FORMED AND USE ONLY WHERE SHOWN OR SPECIFICALLY APPROVED BY THE ENGINEER.

F3.

BEARING MATERIAL AT BASES OF PIERS TO BE CONFIRMED BY AN EXPERIENCED GEOTECHNICAL ENGINEER OR ENGINEERING GEOLOGIST PRIOR TO POURING CONCRETE.

C12.

ALL CONCRETE COLUMNS ARE TO BE POURED A MINIMUM OF 4 HOURS PRIOR TO SLAB OR BEAM OVER.

R6.

WELDING OF REINFORCEMENT SHALL NOT BE PERMITTED WITHOUT THE APPROVAL OF THE ENGINEER.

C13. F4.

EXCAVATION NEAR FOOTINGS SHALL NOT EXTEND BELOW FOUNDATION LEVEL WITHOUT THE ENGINEERS APPROVAL.

DRIP GROOVES ARE TO BE PROVIDED AT ALL EXPOSED EDGES. COVER TO REINFORCEMENT IS TO BE MAINTAINED.

R7.

PROVIDE DISTRIBUTION REINFORCEMENT OR TIE BARS IF NOT SHOWN. WHERE NECESSARY PROVIDE N12-400 CENTRES (SPLICE 450)

C14. F5.

ALL FOOTINGS SHALL BE LOCATED CENTRALLY UNDER WALLS AND COLUMNS UNLESS NOTED OTHERWISE

CONDUITS, PIPES AND THE LIKE SHALL NOT BE PLACED WITHIN THE CONCRETE COVER.

R8.

C15. F6.

DO NOT BACKFILL RETAINING WALLS (OTHER THAN CANTILEVER WALLS) UNTIL FLOOR CONSTRUCTION AT TOP AND BOTTOM IS COMPLETED.

ALL CONCRETE (INCLUDING FOOTINGS AND SLABS ON GROUND) SHALL BE MECHANICALLY VIBRATED TO ACHIEVE FULL COMPACTION.

SITE BENDING OF N BARS SHALL BE DONE COLD WITH POWER OR MECHANICAL BENDING TOOLS AND A MANDREL OR FORMER WITH A BAR DIAMETER OF 5 TIMES THE BAR SIZE. NOTE: IF N BARS ARE HEATED ABOVE 450°C (LESS THAN RED HEAT) THEY LOSE STRENGTH.

C16.

SAWN CUT JOINTS ARE TO BE CUT AFTER THE CONCRETE HAS SUFFICIENTLY HARDENED SUCH THAT WILL NOT BE DAMAGED BY THE SAWING BUT BEFORE SHRINKAGE CRACKING CAN OCCUR.

F8. F9.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR MAINTAINING ANY EXCAVATION IN A STABLE CONDITION WITHOUT ADVERSELY AFFECTING SURROUNDING PROPERTY INCLUDING SERVICES. THIS INCLUDES OBTAINING ALL NECESSARY APPROVALS FOR SHORING AND ANCHOR SYSTEMS.

C17.

ANY OVER EXCAVATION SHALL BE BACKFILLED WITH CONCRETE GRADE N15. FOUNDATIONS ADJACENT TO SERVICES ETC. SHALL BE EXTENDED DOWN SUCH THAT THE INFLUENCE LINE OF THE FOUNDATION IS BELOW THE ADJACENT SERVICE.

CONCRETE NOTES C1.

C2.

ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH AS 3600 CURRENT EDITIONS WITH AMENDMENTS, EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS. ALL CONCRETE SUPPLY SHALL COMPLY WITH AS1379. CONCRETE PROPERTIES AND COVER TO REINFORCING SHALL BE AS FOLLOWS : COVER = F'c (MPA) (28 DAYS) = MAX 28 DAYS SHRINKAGE = MAX 56 DAYS SHRINKAGE = MAXIMUM AGGREGATE SIZE = SLUMP DURING PLACEMENT = EXPOSURE CLASSIFICATION = =

REFER TO DRAWINGS REFER TO DRAWINGS 600 MICRO STRAIN UNO 700 MICRO STRAIN UNO 20mm UNO 80mm UNO N/A (INTERNAL) B1 (EXTERNAL)

C3.

CEMENT TO BE TYPE SL TO AS 3972 UNLESS NOTED OTHERWISE. THIS IS A MODIFIED TYPE 'GP' CEMENT. SEE ACSE CONCRETE SPECIFICATION.

C4.

NO 'BRECCIA' TYPE AGGREGATE IS TO BE USED.

C5.

C18.

R9.

CURING OF ALL CONCRETE SHALL BE IN ACCORDANCE WITH AS3600 AND SHALL COMMENCE WITHIN 2 HOURS OF FINISHING OPERATIONS. CURING SHALL BE BY CONTINUAL SATURATION WITH PORTABLE WATER FOR 3 DAYS FOLLOWED BY PREVENTION OF MOISTURE LOSS FOR THE NEXT 4 DAYS USING POLYTHENE SHEETING OR WET HESSIAN PROTECTED FROM WIND OR TRAFFIC AND THEN ALLOWING GRADUAL DRYING OUT. CURING COMPOUNDS MAY BE USED PROVIDED THAT THEY COMPLY WITH AS3799 AND DO NOT AFFECT THE APPLICATION OF FLOOR FINISHES. THE COMPATIBILITY OF CURING COMPOUNDS WITH PROPOSED APPLIED FINISHES SHALL BE VERIFIED PRIOR TO APPLICATION. CURING COMPOUNDS ARE TO BE APPLIED UNIFORMLY IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATION. PVA BASED CURING COMPOUNDS ARE NOT ACCEPTABLE.

ENSURE ADEQUATE SUPPLY OF ALIPHATIC ALCOHOL ON SITE BEFORE COMMENCING CONCRETE WORK.

C20.

SLIP JOINTS ARE TO BE USED ON ALL LOAD BEARING MASONRY WALLS. USE TWO LAYERS OF GALVANIZED FLAT STEEL WITH GRAPHITE GREASE BETWEEN, ON INTERNAL SKIN & TWO LAYERS OF FLAT STAINLESS STEEL WITH GRAPHITE GREASE BETWEEN, ON EXTERNAL SKINS. PROVIDE MORTAR LEVELLING STRIP AS REQUIRED.

C21.

NON LOAD BEARING MASONRY SHALL BE SEPARATED FROM THE SOFFIT OF SLABS AND BEAMS BY 20mm. PROVIDE SUITABLE HEAD RESTRAINT TIES AS REQUIRED.

C22.

MASONRY WALLS MUST NOT BE CONSTRUCTED ON SUSPENDED CONCRETE UNTIL ALL TEMPORARY SUPPORTS ARE REMOVED AND ALL MASONRY TO BE LAID HAS BEEN STACKED ADJACENT TO PROPOSED POSITION.

LAP REINFORCEMENT ONLY AT LOCATIONS SHOWN ON THE STRUCTURAL DRAWINGS OR AS OTHERWISE APPROVED IN WRITING BY THE STRUCTURAL ENGINEER. SLAB REINFORCEMENT - LAP LENGTH (mm) CONCRETE GRADE

BAR DIA.

25 MPa

32 MPa

40 MPa

N12 N16 N20

600 850 1100

500 750 1000

450 650 900

BEAM REINFORCEMENT - LAP LENGTH (mm) BAR DIA.

ALIPHATIC ALCOHOL:WHEN SHADE TEMPERATURE EXCEEDS 35° C SPRAY THE EXPOSED SURFACE OF CONCRETE SLAB DURING THE PLACING AND FINISHING OPERATION WITH A FINE FILM OF APPROVED ALIPHATIC ALCOHOL. REPEAT THE SPRAY IF THE SPRAYED SURFACE HAS BEEN RE-WORKED.

C19.

NO ADMIXTURES SHALL BE USED IN CONCRETE UNLESS APPROVED IN WRITING BY THE ENGINEER.

REINFORCEMENT LAPS

N12 N16 N20 N24 N28 N32 N36

< 300mm CONCRETE CAST BELOW THE BAR

> 300mm CONCRETE CAST BELOW THE BAR

CONCRETE GRADE

CONCRETE GRADE

25 MPa

32 MPa

40 MPa

25 MPa

32 MPa

40 MPa

600 850 1100 1400 1700 2000 2400

500 750 1000 1250 1500 1800 2100

450 650 900 1100 1350 1600 1850

750 1100 1450 1800 2200 2600 3050

650 950 1300 1600 1950 2300 2700

600 850 1150 1400 1700 2050 2400

BAR DIA.

COLUMN AND WALL REINFORCEMENT LAP LENGTH (mm)

N12 N16 N20 N24 N28 N32 N36

500 650 800 950 1150 1300 1450 L

L

L

L L

L

C6. C7.

PROJECT ASSESSMENT OF CONCRETE SHALL BE CARRIED OUT IN ACCORDANCE WITH AS1379.

L

REINFORCEMENT

PROJECT CONTROL TESTING SHALL BE CARRIED OUT IN ACCORDANCE WITH AS1379 BY A NATA REGISTERED TESTING LABORATORY. SAMPLES SHALL BE TAKEN FOR TESTING OF: SLUMP, COMPRESSIVE STRENGTH AND ANY OTHER TEST SPECIFIED.

R1.

ALL WORKMANSHIP AND MATERIALS SHALL BE IN ACCORDANCE WITH AS3600, AS4671 AND OTHER RELEVANT AUSTRALIAN CODES.

R2.

REINFORCEMENT TYPE AND GRADE.

SLUMP SHALL BE SAMPLED FOR EACH TRUCK AT THE TIME OF POURING.

SYMBOL

THE MINIMUM FREQUENCY OF SAMPLING FOR COMPRESSIVE TESTING OF EACH TYPE AND GRADE SHALL BE IN ACCORDANCE WITH THE FOLLOWING TABLE:

MPa

50 MAX. 50 MIN.

500

NORMAL

N12 x 1200 LONG AT WIRE CENTRES ALTERNATIVE FABRIC SPLICE DETAIL

NORMAL

W

COLD DRAWN PLAIN ROUND WIRE

500

LOW

SL

SQUARE WELDED MESH

500

LOW

1

1 SAMPLE

RL

RECTANGULAR WELDED MESH

500

LOW

1 TO 5

2 SAMPLES

L TM

RECTANGULAR WELDED MESH

500

LOW

6 TO 10

3 SAMPLES

11 TO 20

4 SAMPLES

SAMPLES SHALL BE TESTED FOR COMPRESSIVE STRENGTH AS FOLLOWS: ONE CYLINDER AT 3 DAYS (POST TENSIONED CONCRETE ONLY) ONE CYLINDER AT 7 DAYS TWO CYLINDERS AT 28 DAYS

MINIMUM OVERLAP

HOT ROLLED DEFORMED BARS

250

1 ADDITIONAL SAMPLE

LAPS IN MESH (FABRIC) SHALL COMPLY WITH AS3600. THE TWO OUTERMOST TRANSVERSE WIRES OF ONE SHEET SHALL OVERLAP THE TWO OUTERMOST TRANSVERSE WIRES OF THE SHEET BEING LAPPED BY 25MM. A MAXIMUM OF 3 SHEETS OF MESH SHALL BE LAPPED AT ANY POINT.

N

HOT ROLLED PLAIN BARS

R3.

R10.

DUCTILITY CLASS

R

FOR EACH ADDITIONAL 10

C8.

TYPE

NUMBER OF SAMPLES 1 SAMPLE = 3 CYLINDERS (4 CYLINDERS FOR POST TENSIONED CONCRETE)

NUMBER OF BATCHES PER DAY

L

ALL REINFORCEMENT TO CONFORM TO AS4671, CURRENT EDITIONS WITH AMENDMENTS. REINFORCEMENT NOTATION GIVES THE FOLLOWING INFORMATION: NO. OF BARS, TYPE, SIZE (MM), SPACING (MM), LAYER. FOR EXAMPLE 17N16 -250 T

R11.

SLAB REINFORCEMENT SHALL EXTEND 70mm ONTO SUPPORTING WALLS, WITH 50% OF BOTTOM BARS COGGED TO ACHIEVE ANCHORAGE AT SIMPLY SUPPORTED ENDS. MESH IN SLABS SHALL EXTEND 70mm ONTO SUPPORTING WALLS WITH A CROSS WIRE.

R12.

ALL BEAM TIES ARE TO HAVE BAR ANCHORAGES LOCATED ON THE TOP FACE OF THE BEAM UNO.

R13.

REINFORCEMENT BAR JOGGLES SHALL BE 1 BAR DIAMETER OVER A LENGTH OF 12 BAR DIAMETERS.

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C101-10.dwg

F7.

SUPPORT REINFORCEMENT ON MILD STEEL PLASTIC TIPPED CHAIRS, PLASTIC CHAIRS OR CONCRETE CHAIRS AT NOT GREATER THAN 1 METRE CENTRES BOTH WAYS. IN EXPOSED CONDITIONS B2 OR C (TO AS3600) USE ONLY PLASTIC OR CONCRETE CHAIRS.

FABRIC OR MESH NOTATION GIVES THE FOLLOWING INFORMATION: “RL” OR “SL”, PRODUCT CODE, LAYER. FOR EXAMPLE SL82 T

BEAM DEPTHS ARE WRITTEN FIRST AND INCLUDE SLAB THICKNESS. R4.

REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY AND NOT NECESSARILY SHOWN IN TRUE PROJECTION.

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

CONSTRUCTION NOTES SHEET 2 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C101-102

B

Mar 06, 2024 - 9:09am

F1.

CONCRETE NOTES CONT:


LEGEND

AM KH KIR

SHEET LAYOUT

NE LA

5 T

SH

EE

LIZ KERN

IVE

7

SH

OHAN DR

ET

EE

6 T

SHE

2 T

ET SHE

RS

AY W Y

TR

LE L A

8

T EE

V

3 T E

DE

EN D M CA

AY

HIL

1 T E E H S

N

DE M A C

SH

EE

E H S

E E SH

4 T

YW E L VAL

LIZ

200

300

400

500 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-00.dwg

100

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KEY PLAN

Drawn

Date

Scale

JER

MAR 2023

1:5000

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-001

B

Mar 06, 2024 - 9:10am

50

T9

0

E SHE

E RIV

ND

HA

NO KER

SCALE 1:5000 @ A1 SCALE 1:10000 @ A3


LEGEND ADJOINS SHEET 2

EXISTING BOUNDARY INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

NOTES: 1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

EXISTING SAFETY BARRIER TO BE REMOVED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

80 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

TC 84.03

/

/

/

/

40

/

/

/

/

200 /

183.84 CTP 183.87

/

180

/

170.08

/

160

/

140

/

120

/

/

/

/

/

/

CAMDEN VA L

/

0.00

/

EXISTING RCBC HEADWALL TO BE REMOVED

/

/

/

/

/

LEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCB1

EXISTING SAFETY BARRIER TO BE REMOVED

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-201

B

Mar 06, 2024 - 9:10am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

EXISTING RCBC HEADWALL TO BE REMOVED


EXISTING BOUNDARY

ADJOINS SHEET 3

ADJOINS SHEET 1

LEGEND

INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

NOTES: 1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

500

320

340

TC 344.60

/

297.63 300

380

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

289.31

400

/

/

/

/

/

/

/

/

/

/

/

280

420

/

/

/

/

/

/

/

/

/

/

/

/

/

260

440

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

240

480 /

236.26

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220 220.07 CT

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

183.84 CTP 183.87

/

/

/

/

/

/

/

/

180

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCB1

/

MCB1

360 CT 360.02

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100 102.83 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

80 "KIRKHAM PARK" SIGN AND GARDEN TO BE RELOCATED. T.B.C BY CAMDEN COUNCIL LANDSCAPE ARCHITECT'S

CT 71.44

TIMBER BOLLARD TO BE REMOVED (TYP.) /

60 /

/

/

EXISTING KERB AND GUTTER TO BE REMOVED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

/

/

/

TC 35. 97 40 /

/

/

/

/

/

/

/

/

/

/

EXISTING SHARED PATH TO BE REMOVED

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

/ / /

/ / /

0.00

/

/

/

/

/

/

/

/

/

/

/

/

/

/

HILDE

/

/

/

ADJOINS SHEET 3

/

/

/

/

/

/

/

EXISTING KERB RAMP TO BE REMOVED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-202

B

Mar 06, 2024 - 9:10am

/

/ /

EXISTING KERB AND GUTTER TO BE REMOVED

/

EET R STR

EXISTING KERB RAMP TO BE REMOVED ADJOINS SHEET 1

MC03

/

20

EXISTING SHARED PATH TO BE REMOVED

/

/

/

/

/

/

EXISTING FENCE TO BE REMOVED


/

/

/

/ /

/

/

LEGEND

/

/

/ /

/ /

/

/

/

/

/

/

/ /

/

/

ADJOINS SHEET 5

/

ADJOINS SHEET 5

/

/

/

160

/

/ /

/

/

/

/

/

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

180

INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

EXISTING BOUNDARY

/

/

/

/

/

/

/

KIRKHAM LANE

/

/

/

/

/

MCA2

/

NOTES:

/

/

/

/

200

/

/

/

/

/

/

/

/

/

1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

EXISTING RCBC HEADWALL TO BE REMOVED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

REMOVE EXISTING SAFETY BARRIER

240

/ / /

800

780

760

740

MCB1

/

/

/

/

/

720

/

/

/

/ /

/

/

640

/ / / / /

700

/ / /

/

660

/

/

/

/

/

/

/

/

/

/

255.48 257.25 260

/

MCB1

/

680

671.96 CT 674.84

/

/ / / / /

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

/

/

667.41

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 269.56

278.06 0.00 TC 0.05

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20 DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

40.00 EXISTING SHARED PATH TO BE REMOVED

EXISTING SHARED PATH TO BE REMOVED

EXISTING KERB AND GUTTER TO BE REMOVED

CT 59.76 60

REMOVE EXISTING SAFETY BARRIER.

MCA1

ADJOINS SHEET 6 / /

5

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

/

0

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-203

B

Mar 06, 2024 - 9:10am

100

120

ADJOINS SHEET 6

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

80

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

EXISTING RCBC HEADWALL TO BE REMOVED


LEGEND ADJOINS SHEET 3

EXISTING BOUNDARY INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

NOTES:

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

945.79

/ /

//

//

//

//

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

940

920

900

880

860

840

820

800

MCB1

/

/

/

/

/

/

/

/

/

/

/

TC 864.55

1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / /

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

/

/ / /

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-204

B

Mar 06, 2024 - 9:10am

/

ADJOINS SHEET 3

/

/

/

/

/

/

/

/

/

/

CAMDEN VALLEY WAY


LEGEND EXISTING BOUNDARY INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

NOTES: 1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

0.00 / /

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

20

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

40

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/ /

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / / / / / /

/ / / / / / / /

/ /

80

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

KIRKHAM LANE

/

/ /

/ / / / / / / / / /

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/ /

REMOVE EXISTING SAFETY BARRIER. /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

120

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/ /

/

/ /

/

/ /

/

/

/

/

/ /

/

/

/

/

160

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-205

B

Mar 06, 2024 - 9:10am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

/

140


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 3 EXISTING BOUNDARY

120 /

INFRASTRUCTURE TO BE DEMOLISHED

/

/

TC 127.23

/

/

/

/ /

/ /

/

/

/

/

/

/ / /

/

/ /

/

/

/ / /

/

/

/

/

/

/

/

/

/ / /

/ /

PAVEMENT TO BE DEMOLISHED

/ /

/

/

/

/

140

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

/ /

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

/ /

/

/

/

/

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

160

/ /

/ /

NOTES:

/

/

/

/

/ / /

/ /

/

1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

/

/ /

/

/

/ /

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

180

/

/ /

/ /

/ /

/

/ /

/

/

/

/ / /

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

53

/

/

/

/

0 201. 0 2 T C

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

MCA1

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

60

/

8709.00

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ / /

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

AN

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

DR

/

/

/

/

/

/

/

/

/

/

/

/

MC01

/

/

ER B IN 0 E H 26

/

/

E IV

/

0

/

/

/

/ /

/

0.0

/

/

/

/

RS E G

.73

9 24

/ / /

/

R

CIR

/

/

2

IT U C

/

/

40

/

/

OH RN

KE

/

90. 08

/

/

2

20

/

LIZ

/

/

.59

/

/

/

40 C 40 T

/

.46 4 2

/

/

0

22

/ /

/ / /

/ / /

/ / / / / /

0

/

28

/ /

/ / / /

/ / / / / /

/ / / /

/ / / /

2

/

0

.0 95

/

0

/

30

/ / /

/ / /

/ /

/

/

/

/

/

/

/ /

/

/ / /

/ /

/

/ /

/ /

/

/

/ / /

/ /

/

/

/ / /

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

.60 2 0 32 C 32 T

/

/

/ /

/

/

/ / / / / / / / / / /

/ / / / / /

/ / / / / / / / / / / /

/

/ / /

/ / / /

/

/ / / / / / / / / /

/

/ / / / / / / / / / / /

/

0

/ /

34

/ / / / /

/ / / / / /

/ / / / / / /

/ / / / /

/ / / / / / /

/ / / / / / / /

/ / / /

/ / / / /

ET

/ /

/ / / /

/ / / /

S 360 DJOIN A

/

REMOVE EXISTING SAFETY BARRIER.

/ /

/

E SH

7

/ / / / /

/ / / /

/ /

/ / / / / /

/ / / /

/

380

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-206

B

Mar 06, 2024 - 9:11am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / / / / /

EXISTING BOUNDARY

ADJOINS SHEET 8

/

/ / / / / / / /

/

/

/

/

/

/

/

/

/

/

/

MC02

40 41.00 CT 45.42

INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

/

/

/

/

/

57.75 DEMOLISH AND REMOVE EXISTING KERB

/

GRIMES AVENUE

/

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

58

C2 6.

/

/

/

/

/

/

/

/

/

1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

.07

/

CT

/

/

/

/

0

/

/

/

/

/

/

/

0.0

480

54 8

.73

540

/

498 TC 500

20

520

527.72

T

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

NOTES:

/

56 0

/

/

/

/

460

/

/

/

PAVEMENT TO BE DEMOLISHED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

58 0

/ / / / / / / / / / / / / /

EIN RH

420 .36 3 2 4 CT

/

/

/

/

440

/

/ /

60 0

/ / / / / / / /

/ / / / /

4.0 0

62

/

/

/

/

62 0

/

/

/

/

R

/

/

/

/

/

/

/

64

/

0

/

/

/

/

/

/

/

/

/

/

38

/

/

IT

CU 0

N

E

/

CIR

E K Z LI

HA O N

IV R D

/

0 40

S ER

RG BE

MCA1

/

/

/

/

/

/

36 0

/

/

0

/

66

/ / / / /

720

700

64 679.

680 /

/

/

/

/

/

/

/

/

/

T6 EE SH

/

S IN

/

JO AD

DEMOLISH AND REMOVE EXISTING CONCRETE MEDIAN ISLAND, INCLUDING KERB

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA1 /

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/ /

/ /

/ / /

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6 ET

E SH

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-207

B

Mar 06, 2024 - 9:11am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


EXISTING BOUNDARY

ADJOINS SHEET 9

ADJOINS SHEET 7

LEGEND

INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

NOTES: 1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1040

1020

1000

980 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

960

940

920

900 900.58

879.00 880

870.98

860

840

/ / / / /

/

800

780 /

/

MCA1 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LIZ KERNOHAN DRIVE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

760

740

720 /

820

BOLLARD TO BE REMOVED

/

/ / / /

/

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-208

B

Mar 06, 2024 - 9:11am

ADJOINS SHEET 9

ADJOINS SHEET 7

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 8

EXISTING BOUNDARY INFRASTRUCTURE TO BE DEMOLISHED PAVEMENT TO BE DEMOLISHED

TREES TO BE REMOVED TOTAL TO BE REMOVED: 100

NOTES:

/

1180

1184.83

/

/ / / / /

/

/

/

/

/

/

/

1160

/

/

MCA1

/

1140 1144.00 CT 1145.93

/

/

/

CT 1 TC 1 112.23 113.9 9 1120

1100

TC 1091.21

1080

/

/

/

1040

/

1060

/

/

/

/

/

/

/

1. REFER TO SHEETS C112-001 TO C112-009 AND C112-101 TO C112-109 UTILITY INFORMATION. 2. EXTENT OF DEMOLITION IS INTERPRETED FROM THE PROJECT DETAIL SURVEY INFORMATION. ALL DEMOLITION WORKS TO BE CONFIRMED BY CONSTRUCTION CONTRACTOR.

/

/

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DEMOLITION PLANS SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C102-209

B

Mar 06, 2024 - 9:11am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C102-20.dwg

LIZ KERNOHAN DRIVE


LEGEND ADJOINS SHEET 2

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

SEDIMENT FENCE TO SD 6-8 MESH AND GRAVEL INLET FILTER TO SD 6-11 GEOTEXTILE INLET FILTER TO SD 6-12 STABILISED SITE ACCESS TO SD 6-14 ROCK CHECK DAM TO SD5-4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

80 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

TC 84.03

/

/

/

/

40

/

/

/

/

200 /

183.84 CTP 183.87

/

180

/

170.08

/

160

/

140

/

120

/

/

/

/

/

/

CAMDEN VA L

/

0.00

/

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

/

/

/

/

LEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-001

B

Mar 06, 2024 - 9:11am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

MCB1


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 1

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

SEDIMENT FENCE TO SD 6-8 MESH AND GRAVEL INLET FILTER TO SD 6-11 GEOTEXTILE INLET FILTER TO SD 6-12 STABILISED SITE ACCESS TO SD 6-14 ROCK CHECK DAM TO SD5-4

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

500

340

TC 344.60

/

320

360 CT 360.02

/

297.63 300

380

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

289.31

400

/

/

/

/

/

/

/

/

/

/

/

280

420

/

/

/

/

/

/

/

/

/

/

/

/

/

260

440

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

240

480 /

236.26

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220 220.07 CT

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

183.84 CTP 183.87

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCB1

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

180

MCB1

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100 102.83 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

80

CT 71.44 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60 /

/

/

/

/

/

/

/

/

/

/

/

TC 35. 97 40 / / /

/ / / / /

/

/ / / / / /

/ / / / / /

/ / /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-002

B

Mar 06, 2024 - 9:11am

/ /

ADJOINS SHEET 3

0.00

/

/

/

/

/

/

/

/

/

/

/

/

HILDE

/

/

/

/

/

/

/

/

/

/

R STR

20 ADJOINS SHEET 1

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

/

/

/

/

/

EET

/

/

/

/

/

/

/

/

/

MC03


/

/

/

/ /

/

/

LEGEND

/

/

/ /

/ /

/

/

/

/

/

/

/ /

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

/

/

ADJOINS SHEET 5

/

ADJOINS SHEET 5

/

/

/

160

/

/ /

/

/

/

/

/

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

MESH AND GRAVEL INLET FILTER TO SD 6-11

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

180

SEDIMENT FENCE TO SD 6-8

/

/

/

/

/

/

/

KIRKHAM LANE

STABILISED SITE ACCESS TO SD 6-14

/

/

/

/

/

/

MCA2

/

/

/

/

/

200

/

/

/

/

/

/

/

/

ROCK CHECK DAM TO SD5-4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

GEOTEXTILE INLET FILTER TO SD 6-12

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220

240

/ / /

800

780

760

740

MCB1

/

/

/

/

/

720

/

/

/

/ /

/

/

640

/ / / / /

700

/ / /

/

660

/

/

/

/

/

/

/

/

/

/

255.48 257.25 260

/

MCB1

/

680

671.96 CT 674.84

/

/ / / / /

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

/

/

667.41

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 269.56

278.06 0.00 TC 0.05

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20

40.00

CT 59.76 60

ADJOINS SHEET 6 / /

5

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

/

0

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-003

B

Mar 06, 2024 - 9:11am

100

120

ADJOINS SHEET 6

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

80

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

MCA1


LEGEND ADJOINS SHEET 3

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

SEDIMENT FENCE TO SD 6-8 MESH AND GRAVEL INLET FILTER TO SD 6-11 GEOTEXTILE INLET FILTER TO SD 6-12 STABILISED SITE ACCESS TO SD 6-14 ROCK CHECK DAM TO SD5-4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

945.79

/ /

//

//

//

//

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

940

920

900

880

860

840

820

800

MCB1

/

/

/

/

/

/

/

/

/

/

/

TC 864.55

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / /

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

/

/ / /

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-004

B

Mar 06, 2024 - 9:12am

/

ADJOINS SHEET 3

/

/

/

/

/

/

/

/

/

/

CAMDEN VALLEY WAY


LEGEND REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

SEDIMENT FENCE TO SD 6-8 MESH AND GRAVEL INLET FILTER TO SD 6-11 GEOTEXTILE INLET FILTER TO SD 6-12 STABILISED SITE ACCESS TO SD 6-14 ROCK CHECK DAM TO SD5-4

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

0.00 / /

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

20

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

40

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/ /

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / / / / / /

/ / / / / / / /

/ /

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

KIRKHAM LANE

/

/ /

/ / / / / / / / / /

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/ /

80

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

120

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/ /

/

/ /

/

/ /

/

/

/

/

/ /

/

/

/

/

160

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-005

B

Mar 06, 2024 - 9:12am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

/

140


LEGEND ADJOINS SHEET 3

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

ADJOINS SHEET 3

120 /

SEDIMENT FENCE TO SD 6-8

/

/

TC 127.23

/

/

/

/ /

/ /

/

/

/

/

/

/ / /

/

/ /

/

/

/ / /

/

/

/

/

/

/

/

/

/ / /

/ /

MESH AND GRAVEL INLET FILTER TO SD 6-11

/ /

/

/

/

/

140

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

GEOTEXTILE INLET FILTER TO SD 6-12

/ /

/ /

/

/

/

/

/

/

/ /

/

/

/ /

/ /

/ /

/ /

STABILISED SITE ACCESS TO SD 6-14

/ /

/ /

160

/ /

/ /

/

/

/

/

/ / /

/ /

/ /

/ /

ROCK CHECK DAM TO SD5-4

/

/

/ /

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

180

/

/ /

/ /

/ /

/

/ /

/

/

/

/ / /

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

53

/

/

/

/

0 201. 0 2 T C

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

MCA1

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

60

/

8709.00

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ / /

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

0

/

/

/

0

/

/

/

G ER

/

/

/

E IV

/

C S R

E

B N I E

/

/ / / /

26

/

/

/

.73

/

/

/

DR

/

IRC

9 24

0.0

/

/

/

UIT

/

/

AN

/

2

/

/

40 MC01

/

/

OH RN

KE

/

90. 08

/

/

2

20

/

LIZ

/

/

.59

/

/

/

40 C 40 T

/

.46 4 2

/

/

0

22

/

RH

/ /

/ / /

/ / /

/ / / / / /

0

/

28

/ /

/ / / /

/ / / / / /

/ / / /

/ / / /

2

/

0

.0 95

/

0

/

30

/ / /

/ / /

/ /

/

/

/

/

/

/

/ /

/

/ / /

/ /

/

/ /

/ /

/

/

/ / /

/ /

/

/

/ / /

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

.60 2 0 32 C 32 T

/

/

/ /

/

/

/ / / / / / / / / / /

/ / / / / /

/ / / / / / / / / / / /

/

/ / /

/ / / /

/

/ / / / / / / / / /

/

/ / / / / / / / / / / /

/

0

/ /

34

/ / / / /

/ / / / / /

/ / / / / / /

/ / / / /

/ / / / / / /

/ / / / / / / /

/ / / /

/ / / / /

ET

/ /

/ / / /

/ / / /

/

S 360 DJOIN A

/ /

/

E SH

7

/ / / / /

/ / / /

/ /

/ / / / / /

/ / / /

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-006

B

Mar 06, 2024 - 9:12am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

/

380


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

GRIMES AVENUE

/

/

/

/

/

/

/

/

/

ADJOINS SHEET 8

/

/

/

/

/

/

/

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

57.75 40 41.00 CT 45.42

SEDIMENT FENCE TO SD 6-8 MESH AND GRAVEL INLET FILTER TO SD 6-11

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MC02

GEOTEXTILE INLET FILTER TO SD 6-12

58

C2 6.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

ROCK CHECK DAM TO SD5-4

.07

/

CT

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

/

/

/

0

/

/

/

/

/

/

/

0.0

480

54 8

.73

540

/

498 TC 500

20

520

527.72

T STABILISED SITE ACCESS TO SD 6-14

/

56 0

/

/

/

/

/

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

58 0

/ / / / / / / / / / / / / /

EIN RH

420 .36 3 2 4 CT

/

/

/

/

440

/

/ /

60 0

/ / / / / / / /

/ / / / /

4.0 0

62

/

/

/

/

62 0

/

/

/

/

R

/

/

/

/

/

/

/

64

/

0

/

/

/

/

/

/

/

/

/

/

38

/

/

IT

CU 0

N

E

/

CIR

E K Z LI

HA O N

IV R D

/

0 40

S ER

RG BE

MCA1

/

/

/

/

/

/

36 0

/

66

/

0

/

/

/

JO AD

720

700

679.

680 /

/

/

/

/

/

/

/

/

/

/

T6 EE SH

64

/

/

/

/

S IN

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA1 /

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/ /

/ /

/ / /

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6 ET

E SH

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-007

B

Mar 06, 2024 - 9:12am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 9

ADJOINS SHEET 7

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

SEDIMENT FENCE TO SD 6-8 MESH AND GRAVEL INLET FILTER TO SD 6-11 GEOTEXTILE INLET FILTER TO SD 6-12 STABILISED SITE ACCESS TO SD 6-14 ROCK CHECK DAM TO SD5-4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1040

1020

1000

980 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

960

940

920

900 900.58

879.00 880

870.98

860

840

/ / / / /

/

800

780 /

/

MCA1 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LIZ KERNOHAN DRIVE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

760

740

720 /

820

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

/ / / /

/

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-008

B

Mar 06, 2024 - 9:12am

ADJOINS SHEET 9

ADJOINS SHEET 7

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 8

REFER TO LANDCOM: SOILS AND CONSTRUCTION VOL 1, 4TH EDITION, MARCH 2004

SEDIMENT FENCE TO SD 6-8 MESH AND GRAVEL INLET FILTER TO SD 6-11 GEOTEXTILE INLET FILTER TO SD 6-12 STABILISED SITE ACCESS TO SD 6-14 ROCK CHECK DAM TO SD5-4

/

1180

1184.83

/

/ / / / /

/

/

/

/

/

/

/

1160

/

/

MCA1

/

1140 1144.00 CT 1145.93

/

/

/

CT 1 TC 1 112.23 113.9 9 1120

1100

TC 1091.21

1080

/

/

/

1040

/

1060

/

/

/

/

/

/

/

U-SHAPE SEDIMENT TRAP WITH SPILL-THROUGH WIER

/

/

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL PLANS SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-009

B

Mar 06, 2024 - 9:12am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-00.dwg

LIZ KERNOHAN DRIVE


1.

PROVIDE EROSION AND SEDIMENT CONTROL MEASURES DURING CONSTRUCTION TO COUNCIL STANDARDS AND CONFORMING TO LANDCOM SOILS & CONSTRUCTION Vol 1, 4th EDITION, MARCH 2004.

2.

PREPARE EROSION AND SEDIMENT CONTROL PLAN AND OBTAIN COUNCIL APPROVAL PRIOR TO WORKS.

3.

ALL PERIMETER CONTROL DEVICES ARE TO BE INSTALLED PRIOR TO WORK COMMENCING AND BE MAINTAINED DURING CONSTRUCTION. LOCATE SEDIMENT FENCE WITHIN WORKS BOUNDARY.

4.

CONTRACTOR TO DEFINE ACCESS, STOCKPILE AND OTHER AREAS PRIOR TO WORK COMMENCING.

5.

PROVIDE A SINGLE POINT OF ACCESS TO THE SITE.

6.

22.

PRIOR TO THE CONTROLLED DISCHARGE (E.G. - WATERING ACTIVITIES FROM EXCAVATIONS AND SEDIMENT BASINS) OF ANY WATER FROM THE SITE DURING CONSTRUCTION. THE FOLLOWING WATER QUALITY OBJECTIVES MUST BE ACHIEVED: TSS - MAXIMUM 50mg/L TURBIDITY MAXIMUM 50NTU pH BETWEEN 6 AND 8 < 80% AND > 20% SATURATED DISSOLVED OXYGEN HAVE NO VISIBLE LITTLE OR WASTE MATTER NO ODOUR OR VISIBLY PETRO CHEMICAL SHEEN

23.

IF THE CONCENTRATION OF TSS IS HIGHER THAN 50mg/L AFTER 5 DAYS, THE CONTRACTOR WILL REQUIRE THE USE OF FLOCCULANTS TO ACHIEVE THE TSS CRITERIA. DOSAGE RATES FOR FLOCCULATION WILL BE DETERMINED ON SITE.

24.

PRIOR TO ANY FORECAST WEATHER EVENT LIKELY TO RESULT IN SEDIMENT LADEN RUNOFF ON THE SITE. ANY EXISTING DETENTION BASINS/ TRAPS SHALL BE DE-WATERED TO PROVIDE SUFFICIENT CAPACITY TO CAPTURE SEDIMENT LADEN WATER FROM SITE PRIOR TO THE WEATHER EVENT.

25.

ANY SEDIMENT LADEN WATER CAPTURED ONSITE MUST BE TREATED TO ENSURE IT WILL ACHIEVE COUNCIL'S WATER QUALITY OBJECTIVES SPECIFIED IN THESE CONDITIONS. PRIOR TO ITS RELEASE FROM SITE. A SAMPLE OF THE RELEASED TREATED WATER MUST BE KEPT ONSITE IN A CLEAR CONTAINER WITH SAMPLE DATE RECORDED ON IT.

26.

NO ALUMINUM BASED FLOCCULATING/COAGULANTS MAY BE USED ONSITE WITH THE PRIOR WRITTEN PERMISSION FROM AN APPROPRIATE COUNCIL OFFICER. THE APPLICANT MUST HAVE A DEMONSTRATED ABILITY TO USE SUCH PRODUCTS CORRECTLY AND WITHOUT ENVIRONMENTAL HARM PRIOR TO ANY APPROVAL.

27.

THE CHEMICAL/ AGENT (FLOCCULATING/ COAGULANTS) USED IN TYPE D AND TYPE F BASINS TO TREAT TURBID WATER CAPTURED IN THE BASIN MUST BE APPLIED IN CONCENTRATIONS SUFFICIENT TO ACHIEVE COUNCIL'S WATER QUALITY OBJECTIVES. SPECIFIED IN THESE CONDITIONS WITHIN THE 5-DAY RAINFALL DEPTH USED TO CALCULATE THE CAPACITY OF THE BASIN, AFTER A RAINFALL EVENT.

28.

ALL MANUFACTURES INSTRUCTIONS MUST BE FOLLOWED FOR THE USE OF ANY CHEMICALS/ AGENTS ONSITE. EXCEPT WHERE APPROVED BY THE RESPONSIBLE PERSON OR AN APPROPRIATE COUNCIL OFFICER.

29.

SUFFICIENT QUANTITIES OF CHEMICALS/ AGENTS TO TREAT TURBID WATER (FLOCCULATING/ COAGULANTS) MUST BE PLACED SUCH THAT WATER ENTERING THE BASIN/ SEDIMENT TRAP MIXES THE CHEMICAL/ AGENTS AND IS CARRIED INTO THE BASIN/ TRAP.

MINIMISE SITE DISTURBANCE AND REDUCE STOCKPILING TO A LEVEL NECESSARY TO CONSTRUCT THE WORKS. STOCKPILE AREAS, CONSTRUCTION ACCESSES AND NO GO AREAS TO BE DEFINED AND CONFIRMED PRIOR TO COMMENCEMENT OF WORK. FENCE NO GO AREAS.

7.

PROVIDE MEASURES AT STOCKPILES TO DIVERT CLEAN WATER AND COLLECT SEDIMENT DOWNSTREAM, LOCATE STOCKPILES AWAY FROM STORMWATER FLOWS.

8.

PROVIDE AND MAINTAIN PERMANENT GRASSING AS SOON AS POSSIBLE AFTER CONSTRUCTION. STAGE WORKS AS NECESSARY. GRASS SPECIES SHALL BE TO COUNCIL REQUIREMENTS. GRASS TURF TABLEDRAINS AND SWALES. MULCH (IF AVAILABLE FROM SITE CLEARING) AND SEED ALL OTHER DISTURBED AREAS INCLUDING TRENCHES, WHICH HAVE NOT BEEN TURFED. ON COMPLETION OF WORKS PROVIDE STRIP TURFING. SEE GENERAL NOTES.

9.

CONTROL DUST BY WINDBREAKS, WATERING ETC.

10.

EROSION AND SILT PROTECTION MEASURES ARE TO BE MAINTAINED AT ALL TIMES. ADJUST TO SUIT STAGING AND PROGRESS.

11.

HIGH EROSION AREAS, INCLUDING BATTERS TO BE STABILISED WITHIN 7 DAYS OF COMPLETING OF WORKS AND EARLIER IF DIRECTED BY SUPERINTENDENT.

12.

CONSTRUCT THE BASIN PRIOR TO ANY SITE WORKS INCLUDING CLEARING AND SOIL DISTURBANCE FOR USE AS A SEDIMENT BASIN DURING CONSTRUCTION.

13.

NO DISTURBED AREAS SHALL REMAIN DENUDED FOR A PERIOD LONGER THAN 20 DAYS.

14.

AN AREA OF NO MORE THAN 2Ha IS TO BE DISTURBED AT ANY TIME

30.

15.

THE ESCP/SWMP AND IT ASSOCIATED EROSION AND SEDIMENT CONTROL MEASURES MUST BE CONSTANTLY MONITORED, REVIEWED AND MODIFIED AS REQUIRED TO CORRECT DEFICIENCIES. COUNCILS HAS THE RIGHT TO REQUEST CHANGES IF, IN ITS OPINION, THE MEASURES THAT ARE PROPOSED OR HAVE BEEN INSTALLED ARE INADEQUATE TO PREVENT POLLUTION.

ANY BASIN MUST BE DE-WATERED AS SOON AS PRACTICAL. ONCE WATER CAPTURED IN THE BASIN ACHIEVES COUNCIL'S WATER QUALITY OBJECTIVES, SPECIFIED IN THESE CONDITIONS.

31.

SUFFICIENT QUANTITIES OF CHEMICALS/ AGENTS TO TREAT TURBID WATER (FLOCCULATING/ COAGULANTS) MUST BE SECURELY STORED ON-SITE TO PROVIDE FOR AT LEAST THREE COMPLETE TREATMENTS OF ALL BASINS REQUIRING CHEMICALLY TREATMENT ONSITE.

32.

THE APPLICANT MUST ENSURE THAT ON EACH OCCASION A TYPE F OR TYPE D BASIN WAS NOT DE-WATERED PRIOR TO BEING SURCHARGED BY A FOLLOWING RAINFALL EVENT. A REPORT IS PRESENTED TO AN APPROPRIATE COUNCIL OFFICER WITHIN 5 DAYS IDENTIFYING THE CIRCUMSTANCES AND PROPOSED AMENDMENTS, IF ANY, TO THE BASIN'S OPERATING PROCEDURES.

ALL REASONABLE AND PRACTICABLE MEASURES MUST BE TAKEN TO ENSURE STORMWATER RUNOFF FROM ACCESS ROADS AND STABILISED ENTRY/ EXIT SYSTEMS, DRAINS TO AN APPROPRIATE SEDIMENT CONTROL DEVICE.

33.

ALL SEDIMENT BASINS MUST REMAIN FULLY OPERATIONAL AT ALL TIMES UNTIL THE BASINS DESIGN CATCHMENTS ACHIEVES 70% GROUND COVERAGE, OR SURFACE STABILISATION ACCEPTABLE TO COUNCIL.

SEDIMENT DEPOSITED OFF SITE AS A RESULT OF ONSITE ACTIVITIES MUST BE COLLECTED AND THE AREA CLEANED/ REHABILITATED AS SOON AS REASONABLE AND PRACTICABLE.

34.

SETTLED SEDIMENT MUST BE REMOVED AS SOON AS REASONABLE AND PRACTICABLE FROM ANY SEDIMENT BASIN IT IS ANTICIPATED THAT THE NEXT STORM EVENT IS LIKELY TO CAUSE SEDIMENT TO SETTLE ABOVE THE BASIN'S SEDIMENT STORAGE ZONE; OR THE ELEVATION OF SETTLED SEDIMENT IS ABOVE THE TOP OF THE BASIN'S SEDIMENT STORAGE ZONE; OR THE ELEVATION OF SETTLED SEDIMENT IS ABOVE THE BASINS SEDIMENT MARKER LINE.

35.

SCOUR PROTECTION MEASURES PLACES ON SEDIMENT BASIN EMERGENCY SPILLWAYS MUST APPROPRIATELY PROJECT THE SPILLWAY CHUTE AND ITS SIDE BATTERS FROM SCOUR, AND MUST EXTEND A MINIMUM OF 3m BEYOND THE DOWNSTREAM TOE OF THE BASIN'S EMBANKMENT.

16.

17.

18.

19.

ALL ESC MEASURES MUST BE APPROPRIATE FOR THE SEDIMENT TYPE(S) OF THE SOILS ONSITE. IN ACCORDANCE WITH THE BLUE BOOK (MANAGING URBAN STORMWATER - SOILS AND CONSTRUCTION LANDCOM, 2004), OR OTHER CURRENT RECOGNISED INDUSTRY STANDARD FOR EROSION AND SEDIMENT CONTROL FOR AUSTRALIAN CONDITIONS.

NEWLY SEALED HARD-STAND AREA (E.G. ROADS, DRIVEWAYS AND CAR PARKS) MUST BE SWEPT THOROUGHLY AS SOON AS PRACTICABLE AFTER SEALING/ SURFACING TO MINIMISE THE RISK OF COMPONENTS OF THE SURFACING COMPOUND ENTERING STORMWATER DRAINS.

20. STOCKPILES OF ERODIBLE MATERIAL MUST BE PROVEN WITH AN APPROPRIATE PROTECTIVE COVER (SYNTHETIC OR ORGANIC) IF THE MATERIALS ARE LIKELY TO BE STOCKPILED FOR MORE THAN 10 DAYS. 21. STOCKPILES, TEMPORARY OR PERMANENT, SHALL NOT BE LOCATED IN AREAS IDENTIFIED AS NO-GO ZONES ON THE ESCP/SWMP.

36.

EROSION AND SEDIMENT CONTROL NOTES 37.

WRITTEN RECORDS MUST BE KEPT ONSITE OF ESC MONITORING AND MAINTENANCE ACTIVITIES CONDUCTED DURING THE CONSTRUCTION AND MAINTENANCE PERIODS, AND BE AVAILABLE TO THE PCA ON REQUEST.

38.

ALL SITE MONITORING DATA INCLUDING RAINFALL RECORDS, DATES OF WATER QUALITY TESTING, TESTING RESULTS AND RECORDS OF CONTROLLED WATER RELEASES FROM THE SITE. MUST BE KEPT IN AN ON-SITE REGISTER. THE REGISTER IS TO BE MAINTAINED UP TO DATE FOR THE DURATION OF THE APPROVED WORKS AND BE AVAILABLE ON-SITE FOR INSPECTION BY COUNCIL OFFICERS ON REQUEST.

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-10.dwg

EROSION AND SEDIMENT CONTROL NOTES

ALL ESC MEASURES MUST BE INSPECTED: AT LEAST DAILY (WHEN WORK IS OCCURRING ON-SITE); AND AT LEAST WEEKLY (WHEN WORK IS NOT OCCURRING ON-SITE); AND WITHIN 24HRS OF EXPECTED RAINFALL; AND WITHIN 18HRS OF A RAINFALL EVENT THAT CAUSES RUNOFF ON THE SITE)

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL NOTES SHEET 1 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-101

B

Mar 06, 2024 - 9:12am

EROSION AND SEDIMENT CONTROL NOTES


KERB -SIDE INLET

1.5m STAR PICKETS AT MAX. 2.5m CENTRES

WIRE OR STEEL MESH (14 GAUGE X 150 mm OPENINGS) WHERE GEOTEXTILE IS NOT SELF-SUPPORTING

SELF-SUPPORTING GEOTEXTILE

20m MAX. P/ESCP) (UNO ON SWM

GRAVEL-FILLED WIRE MESH OR GEOTEXTILE 'SAUSAGE'

600mm MIN

MIN 1.5m

DROP INLET WITH GRATE

WOVEN GEOTEXTILE

UNDISTURBED AREA

FLOW

ON SOIL, 150mm x 100mm TRENCH WITH COMPACTED BACKFILL AND ON ROCK, SET INTO SURFACE SECTION DETAIL CONCRETE

RUNOFF WATER WITH SEDIMENT

STAR PICKET FITTED WITH SAFETY CAP WOVEN GEOTEXTILE

OVERFLOW TIMBER SPACER TO SUIT

RUNOFF WATER WITH SEDIMENT

SANDBAGS

CONSTRUCTION NOTES:

SEDIMENT

CONSTRUCT SEDIMENT FENCES AS CLOSE AS POSSIBLE TO PARALLEL TO THE CONTOURS OF THE SITE, BUT WITH SMALL RETURNS AS SHOWN IN THE DRAWING TO LIMIT THE CATCHMENT AREA OF ANY ONE SECTION. THE CATCHMENT AREA SHOULD BE SMALL ENOUGH TO LIMIT WATER FLOW IF CONCENTRATED AT ONE POINT TO 50L PER SECOND IN THE DESIGN STORM EVENT, USUALLY THE 10 YR EVENT.

FLOW

STAR PICKETS AT MAXIMUM 2.5m SPACINGS

PLAN

1.

1m MAX

TIMBER SPACER TO SUIT

500mm - 600mm

DISTURBED DIRECTION OF AREA FLOW 1.5m STAR PICKETS AT MAX. 2.5m CENTRES

STAR PICKETS

GEOTEXTILE EMBEDDED 150 mm INTO GROUND

WATERWAY

FILTERED WATER

FILTERED WATER GRAVEL-FILLED WIRE MESH OR GEOTEXTILE `SAUSAGE`

EXCAVATION FOR DROP INLETS AT NON-SAG POINTS, SANDBAGS, EARTH BANK OR EXCAVATION USED TO CREATE ARTIFICIAL SAG POINT

NOTE: THIS PRACTICE ONLY TO BE USED WHERE SPECIFIED IN AN APPROVED SWMP/ESCP. 2.

3.

4.

CUT A 150mm DEEP TRENCH ALONG THE UPSLOPE LINE OF THE FENCE FOR THE BOTTOM OF THE FABRIC TO BE ENTRENCHED.

CONSTRUCTION NOTES

DRIVE 1.5m LONG STAR PICKETS INTO GROUND AT 2.5m INTERVALS (MAX) AT THE DOWN SLOPE EDGE OF THE TRENCH. ENSURE ANY STAR PICKETS ARE FITTED WITH SAFETY CAPS. FIX SELF SUPPORTING GEOTEXTILE TO THE UPSLOPE SIDE OF THE POSTS ENSURING IT GOES TO THE BASE OF THE TRENCH. FIX THE GEOTEXTILE WITH WIRE TIES OR AS RECCOMENDED BY THE MANUFACTURER. ONLY USE GEOTEXTILE SPECIFICALLY PRODUCED FOR SEDIMENT FENCING. THE USE OF SHADE CLOTH FOR THIS PURPOSE IS NOT SATISFACTORY.

EARTH BANK

1.

INSTALL FILTERS TO KERB INLETS ONLY AT SAG POINTS

2.

FABRICATE A SLEEVE MADE FROM GEOTEXTILE OR WIRE MESH LONGER THAN THE LENGTH OF THE INLET PIT AND FILL IT WITH 20m TO 50mm GRAVEL.

3.

FORM AN ELLIPTICAL CROSS-SECTION ABOUT 150MM HIGH X 400MM WIDE.

4.

PLACE THE FILTER AT THE OPENING, LEAVING AT LEAST A 100mm SPACE BETWEEN IT AND THE KERB INLET. MAINTAIN THE OPENING WITH SPACER BLOCKS.

CONSTRUCTION NOTES:

5.

JOIN SECTIONS OF FABRIC AT A SUPPORT POST WITH A 150mm OVERLAP.

5.

FORM A SEAL WITH THE KERB TO PREVENT SEDIMENT BYPASSING THE FILTER.

6.

BACKFILL THE TRENCH OVER THE BASE OF THE FABRIC AND COMPACT IT THROUGHLY OVER THE GEOTEXTILE.

6.

SANDBAGS FILLED WITH GRAVEL CAN SUBSTITUTE FOR THE MESH OR GEOTEXTILE PROVIDING THEY ARE PLACED SO THAT THEY FIRMLY ABUT EACH OTHER AND SEDIMENT-LADEN WATERS CANNOT PASS BETWEEN.

SEDIMENT CONTROL FENCE SD6-8

MESH AND GRAVEL INLET FILTER - SD6-11

NOT TO SCALE

NOT TO SCALE

1.

FABRICATE A SEDIMENT BARRIER FROM GEOTEXTILE OR STRAW BALES.

2.

FOLLOW STANDARD DRAWING 6-7 AND STANDARD DRAWING 6-8 FOR INSTALLATION PROCEDURES FOR THE STRAW BALES OR GEOFABRIC. REDUCE THE PICKET SPACING TO 1m CENTRES.

3.

IN WATERWAYS, ARTIFICIAL SAG POINTS CAN BE CREATED WITH SANDBAGS OR EARTH BANKS AS SHOWN IN THE DRAWING.

4.

DO NOT COVER THE INLET WITH GEOTEXTILE UNLESS THE DESIGN IS ADEQUATE TO ALLOW FOR ALL WATERS TO BYPASS IT.

GEOTEXTILE INLET FILTER SD6-12 NOT TO SCALE

WRAP ENTIRE PIT GRATE IN GEOTEXTILE FILTER FABRIC

DISTURBED AREA

SECTION DETAIL

DIRECTION OF FLOW

GEOTEXTILE FILTER FABRIC

UNDISTURBED AREA

PLAN DETAIL

U-SHAPE SEDIMENT TRAP AND SPILL-THROUGH WEIR

GEOTEXTILE WRAPPED GRATE

NOT TO SCALE

NTS

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL DETAILS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-102

B

Mar 06, 2024 - 9:12am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-10.dwg

FLOW

0.3m

1.0m


ID MIN. W

CONSTRUCTION SITE

TH 3m

MIN. L EN

GTH 1

5m

200mm MIN. DARY

N TY BOU R E P O R P

300mm MIN.

RUNOFF DIRECTED TO SEDIMENT TRAP/FENCE DGB 20 ROADBASE OR 30mm AGGREGATE GEOTEXTILE FABRIC DESIGNED TO PREVENT INTERMIXING OF SUBGRADE AND BASE MATERIALS AND TO MAINTAIN GOOD PROPERTIES OF THE SUB-BASE LAYERS.

STABILISED SITE ACCESS SD6-14

EXISTING ROADWAY

GEOTEXTILE MAY BE A WOVEN OR NEEDLE PUNCHED PRODUCT WITH A MINIMUM CBR BURST STRENGTH (AS3706.9-90) OF 2500 N

NOT TO SCALE

CONSTRUCTION NOTES: 1. STRIP THE TOPSOIL, LEVEL THE SITE AND COMPACT THE SUBGRADE. 2. COVER AREA WITH NEEDLE-PUNCHED GEOTEXTILE. 3. CONSTRUCT 200MM THICK PAD OVER GEOTEXTILE USING ROADBASE OR 30MM AGGREGATE. 4. ENSURE TEH STRUCTURE IS AT LEAST 15m LONG OR TO BUILDING ALIGNMENT AND AT LEAST 3m WIDE. 5. WHERE A SEDIMENT FENCE JOINS ONTO THE STABILISED ACCESS, CONSTRUCT A HUMP IN THE STABILISED ACCESS TO DIVERT WATER TO THE SEDIMENT FENCE.

AGGREGATE OR RECYCLED CONCRETE

SPACING OF CHECK DAMS ALONG CENTRELINE AND SCOUR PROTECTION BELOW EACH CHECK DAM TO BE SPECIFIED ON SWMP/ESCP.

FLOW

CONSTRUCTION NOTES:

2.

TRENCH THE CHECK DAM 200mm INTO GROUND ACROSS ITS WHOLE WIDTH. WHERE ROCK IS USED, FILL THE TRENCHES TO AT LEAST 100mm ABOVE THE GROUND SURFACE TO REDUCE THE RISK UNDERCUTTING.

3.

NORMALLY, THEIR MAXIMUM HEIGHT SHOULD NOT EXCEED 600mm ABOVE THE GULLY FLOOR. THE CENTRE SHOULD ACT AS A SPILLWAY, BEING AT LEAST 150mm LOWER THAN THE EDGES.

4.

SPACE THE DAMS SO THE TOE OF THE UPSTREAM DAM IS LEVEL WITH THE SPILLWAY OF THE NEXT DOWNSTREAM DAM.

SPILLWAY

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C103-10.dwg

CHECK DAMS CAN BE BUILT WITH VARIOUS MATERIALS, INCLUDING ROCKS, LOGS, SANDBAGS AND STRAW BALES. THE MAINTENANCE PROGRAM SHOULD ENSURE THEIR INTEGRITY IS RETAINED, ESPECIALLY WHERE CONSTRUCTED WITH STRAW BALES. IN THE CASE OF BALES, THIS MIGHT REWUIRE THEIR REPLACEMENT EACH TWO TO FOUR MONTHS.

ROCK TRENCHED 200mm INTO GROUND

ROCK CHECK DAM DETAIL (TO SD5-4) NOT TO SCALE

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SOIL EROSION AND SEDIMENT CONTROL DETAILS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C103-103

B

Mar 06, 2024 - 9:12am

1.


LEGEND ADJOINS SHEET 2

CUT -10.0

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m FILL 0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20

/

/

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

80 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

TC 84.03

/

/

/

/

40

/

/

/

/

200 /

183.84 CTP 183.87

/

180

/

170.08

/

160

/

140

/

120

/

0.00

/

/

/

/

/

/

/

CAMDEN VA L

/

/

/

to

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE

/

/

0

/

/

/

/

/

LEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-001

B

Mar 06, 2024 - 9:13am

/

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 1

CUT -10.0

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

500

340

TC 344.60

/

320

360 CT 360.02

/

297.63 300

380

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

289.31

400

/

/

/

/

/

/

/

/

/

/

/

280

420

/

/

/

/

/

/

/

/

/

/

/

/

/

260

440

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

240

480 /

236.26

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220 220.07 CT

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

183.84 CTP 183.87

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE /

/

0

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

180

FILL

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100 102.83 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

80

CT 71.44 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60 / / /

/ / / / /

/

/ / / / / /

/ / / / / /

/ / /

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-002

B

Mar 06, 2024 - 9:13am

/ /

ADJOINS SHEET 3

0.00

/

/

/

/

/

/

/

/

/

/

/

/

HILDE

/

/

/

/

/

/

/

/

/

/

R STR

20 ADJOINS SHEET 1

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

/

/

/

/

/

EET

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 35. 97 40 SCALE 1:500 @ A1 SCALE 1:1000 @ A3


/

/

/

/ /

/

/

LEGEND

/

/

/ /

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

160

/

/ /

/

/

CUT

ADJOINS SHEET 5

/

ADJOINS SHEET 5

/

/

/

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m

/

/

/

/

/

/

/

/

/

/

/

/

/

KIRKHAM LANE

/

/

/

/

/

/

/

200

/

/

/

/

/

/

FILL to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

240

1.0

to

2.0 m

2.0

to

10.0m

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

0

671.96 CT 674.84

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

180

-10.0

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220

800

780

760

740

720

/

/

/

/

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

640

255.48 257.25 260

700

/ / /

/

660

/

/

/

/

/

/

/

/

/

/

/

680

/

/ / / / /

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

/

/

667.41

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 269.56

278.06 0.00 TC 0.05

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20

CT 59.76 60

80

1

120

ADJOINS SHEET 6 / /

5

10

20

30

40

TC 127.23

50 metres

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

2 -101 0 C1

4

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

0

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-003

B

Mar 06, 2024 - 9:13am

100

ADJOINS SHEET 6

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

C104-101

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

40.00


LEGEND ADJOINS SHEET 3

CUT -10.0

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

940

920

900

840

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

820

880

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

945.79

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

800

860 / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 864.55

FILL

/

/

/

/

0

to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / /

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

/

/ / /

/

2 -101 40 SCALE 1:500 @ A1 C10 SCALE 1:1000 @ A3

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-004

B

Mar 06, 2024 - 9:13am

/

ADJOINS SHEET 3

/

/

/

/

/

/

/

/

/

/

CAMDEN VALLEY WAY


LEGEND CUT -10.0

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m FILL

0

to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

0.00 / /

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

20

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

40

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / / / / / /

/ / / / / / / /

/ /

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

KIRKHAM LANE

/

/ /

/ / / / / / / / / /

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/ /

80

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

120

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/ /

/

/ /

/

/ /

/

/

/

/

/ /

/

/

/

/

160

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-005

B

Mar 06, 2024 - 9:13am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

/

140


LEGEND ADJOINS SHEET 3

CUT

ADJOINS SHEET 3

120

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m

/

-10.0 /

/

TC 127.23

2 -101

/

/

/

/ /

/ /

/

/

0 C1

/

/

/

/

4

/ /

/

/ /

/

/

/ / /

/

/

/

/

/

/

/

/

/ / /

/ /

/ /

/

/

/

/

140

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

/ /

/ /

/

/

/

/

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

160

/ /

/ /

/

/

/

/

/ / /

/ /

/ /

/ /

/

/

/

FILL

/

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

180

/

to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

/

0

/

/ /

/ /

/

/ /

/

/

/

/ / /

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

53

/

/

/

/

0 201. 0 2 T C

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

60

/

8709.00

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/ /

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

24

/

/

0

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/

/

3 -101

/

/

C R I C

/

/

04 C1

/

/

RS E G

/

/

/

0

/

/

/

/

0

/

26

/

0.0

/

/

/

/ / /

/ / /

/

IN

/

E RH

R BE

/

/

/

.73

9 24

/

/

/

UIT

/

/

/

E IV DR

/

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE

/

/

AN OH RN KE

90. 08

/

/

40 C 40 T

/

.59

/

/

2

20

/

.46 4 2

/

/

LIZ

2

20

/

/ / /

/ / / / / /

0

/

28

/ /

/ / / /

/ / / / / /

/ / / /

/ / / /

2

/

0

.0 95

/

0

/

30

/

C1

4 -101

/

04

/

/ / /

/ /

/

/

/

/

/

/

/ /

/

/ / /

/ /

/

/ /

/ /

/

/

/ / /

/ /

/

/

/ / /

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

.60 2 0 32 C 32 T

/

/

/ /

/

/

/ / / / / / / / / / /

/ / / / / /

/ / / / / / / / / / / /

/

/ / /

/ / / /

/

/ / / / / / / / / /

/

/ / / / / / / / / / / /

/

0

/ /

34

/ / / / /

/ / / / / /

/ / / / / / /

/ / / / /

/ / / / / / /

/ / / / / / / /

/ / / /

/ / / / /

ET

/ /

/ / / /

/ / / /

/

S 360 DJOIN A

/ /

/

E SH

7

/ / / / /

/ / / /

/ /

/ / / / / /

/ / / /

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-006

B

Mar 06, 2024 - 9:13am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

/

380


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

GRIMES AVENUE

/

/

/

/

/

/

/

/

CUT to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

C2 6.

-0.1

to

-0.05m

20

-0.05

to

0.0m

57.75 40 41.00 CT 45.42

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

ADJOINS SHEET 8

-10.0

58

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

520

.07 498 TC 500

/

527.72

T /

CT

0

to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

/

/

/

/

0

/

/

/

/

/

/

/

0.0

480

54 8

.73

540

FILL

/

56 0

/

/

/

/

/

460

/

/

IVE

/ / / / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

58 0

/

/

/

/

N ER

/

/

/

/

/

/

K Z I L

R ND

/

EIN RH

420 .36 3 2 4 CT

440

A OH

/

/

/

/

/

/

/

0 40

/

S ER

/

/

/

/

/

/

60 0

/

/

/

RG BE

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE

4.0 0

/ /

62

/

/

/

CU

/

/

/

/

/

/

/

64

/

0

/

/

/

/

/

/

/

/

/

/

38

/

/

IT

0

62 0

/

/

/

/

/

CIR

/

/

/

/

/

/

36 0

/

66

/

0

/

/

/

JO AD

720

700

679.

680 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

T6 EE SH

64

/

/

/

/

S IN

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/ /

/ /

/ / /

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6 ET

E SH

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-007

B

Mar 06, 2024 - 9:14am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 9

ADJOINS SHEET 7

CUT -10.0

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m FILL

0

to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1040

1020

1000

980 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

960

940

920

900 900.58

879.00 880

870.98

860

840

/ / / / /

/

800

780

760 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LIZ KERNOHAN DRIVE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

740

720 /

820

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE

/

/ / / /

/

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-008

B

Mar 06, 2024 - 9:14am

ADJOINS SHEET 9

ADJOINS SHEET 7

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 8

CUT -10.0

to

-2.0m

-2.0

to

-1.0m

-1.0

to

-0.5m

-0.5

to

-0.1m

-0.1

to

-0.05m

-0.05

to

0.0m FILL

0

to

0.05 m

0.05

to

0.1 m

0.1

to

0.5 m

0.5

to

1.0 m

1.0

to

2.0 m

2.0

to

10.0m

1184.83

1180

/

/

/

/

/

/

/

/

1160

/

/

/

/

/

/

/

1140 1144.00 CT 1145.93

/

/

/

CT 1 TC 1 112.23 113.9 9 1120

1100

TC 1091.21

1080

/

/

/

/

/

1040

/

1060

/

/

/

/

/

/

/

DEPTHS AND SHADING SHOWN IS FROM DESIGN FINISHED SURFACE TO DETAIL SURVEY SURFACE

/

/

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

BULK EARTHWORKS PLANS SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-009

B

Mar 06, 2024 - 9:14am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-00.dwg

LIZ KERNOHAN DRIVE


MCA1

LIZ KERNOHAN DRIVE

PROPERTY BOUNDARY

PROPERTY BOUNDARY

PROPERTY BOUNDARY

MW01

WATER QUALITY BASIN

5.3m DIVERSION CHANNEL 1

4.17%

3.24%

2.97% 23.87%

2.18%

1.33%

D SECTION

1

10.00%

PROPERTY BOUNDARY

PROPERTY BOUNDARY

3.45%

1.03%

1.68%

0.66%

3.28%

PROPERTY BOUNDARY

C104-003

PROPERTY BOUNDARY

LIZ KERNOHAN DRIVE MCA1

MW01

8.5m TIERED RETAINING WALL

PROPERTY BOUNDARY

1:250

6.72%

D SECTION

PROPERTY BOUNDARY

PROPERTY BOUNDARY

PROPERTY BOUNDARY

RHEINBURGERS CIRCUIT MC01

PROPERTY BOUNDARY

1.83%

0.71%

0.54%

C104-106

PROPERTY BOUNDARY

PROPERTY BOUNDARY

PROPERTY BOUNDARY

1:250

2

2.52%

0.64%

D

SCALE 1:250 @ A1 SCALE 1:500 @ A3

0

2.5

5

10

15

20

SECTION 1:250

C104-106

NOT FOR CONSTRUCTION Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

C104-106

25 metres

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

4

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C104-10.dwg

1:250

3

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EARTHWORKS SECTIONS PLAN

Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C104-101

B

Mar 06, 2024 - 9:14am

SECTION


LEGEND ADJOINS SHEET 2

0.000

ROAD CONTROL LINE

MCXX

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

RKG KG SM SF

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD DESIGN CONTOURS - MAJOR

86

DESIGN CONTOURS - MINOR MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT

EXISTING CONTOURS - MAJOR

86

RETAINING MW02 WALL 1m MAX. REFER RETAINING WALL PLAN AND DETAILS

EXISTING CONTOURS - MINOR

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

40

20

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60

/

/

/

/

/

/

/

/

/

40 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

4 1.2

/

KG

66.00 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

AREA SURROUNDING PROPOSED HEADWALL TO BE REGRADED TO SUIT NEW LEVELS

/

/

REGRADE EXISTING ROAD SIDE DRAIN TOWARDS NEW HEADWALL MERGE BATTER TO HEADWALL

KG /

PROVIDE 30m LONG RUNOUT AREA FOLLOWING MERGE

3.5m 3.5m 3.5m 3.5m 3.5m 3.5m

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100

/

/

/

/

/

/

/

/

/

/

.83

/

/

37

/

/

/

/

TC 84.03 /

/

/

80

44.73

/

200 /

183.84 CTP 183.87

/

180

/

170.08

/

160

/

140

/

120

/

/

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

/

/

18.97 20

SEWER EASEMENT

/

/

/

3.96

/

/

STORMWATER EASEMENT /

MERGE BATTER TO HEADWALL

/

3.5m

3.0m

LEY WAY

4.5m

3.3m

CAMDEN VA L

PROPOSED BOUNDARY

MONOWILLS PEDESTRIAN FENCE

/

0.00

67.00

MERGE BATTER TO HEADWALL

MCB1

/

0.00

/

EXISTING BOUNDARY

DIRECT ROADSIDE DRAIN TO CULVERT INLET MERGE BATTER TO HEADWALL

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-001

B

Mar 06, 2024 - 9:15am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

MONOWILLS PEDESTRIAN FENCE


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 1

0.000

ROAD CONTROL LINE

MCXX

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

RKG KG SM SF

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD

ROUNDABOUT CENTRAL ISLAND. REFER TO C106-511 FOR DETAILS

DESIGN CONTOURS - MAJOR

86 MERGE BATTER TO HEADWALL

DESIGN CONTOURS - MINOR

MONOWILLS PEDESTRIAN FENCE

MCB1

EXISTING CONTOURS - MAJOR

86

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

500

480

460

440

320

297.63 300

340

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

289.31

TC 344.60

/

/

/

/

/

/

/

/

/

/

/

280

360 CT 360.02

/

/

/

/

/

/

/

/

/

/

/

/

/

260

380

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

240

420 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

236.26

400

/

2m 3.5m 3.5m 3.5m 3.5m 3.5m

/

STORMWATER EASEMENT SEWER EASEMENT

KG

66.00

KG /

/

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

66.00

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100 102.83 4.1m

/

/

/

/

/

/

3.5m 3.5m 3.5m 3.5m 3.6m 3.5m

/

m 4.0m 4.0

/

.2m

/

4.2m 4

/

220 220.07 CT

/

200

/

183.84 CTP 183.87

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

KG

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SF

/

EXISTING BOUNDARY PROPOSED BOUNDARY

/

00 66.

/

/

m

4.5m

4.5m

/

/

4.2

SF

m

R12 .5m

MCB1

KG

m 4.2 R14

EXISTING CONTOURS - MINOR

/

KG

/

/

/

/

/

/

180

MERGE BATTER TO HEADWALL

4.1m

66.0 0

80

5.1m SM

4.4m 4.0m

CT 71.44 3.0m

MAKE SMOOTH CONNECTION WITH EXISTING PATH

MERGE BATTER TO HEADWALL MONOWILLS PEDESTRIAN FENCE

CONSTRUCT NEW ROADSIDE DRAIN AT MIN 0.3% GRADE

2.5m SHARED PATH

/

/

/

/

/

/

/

/

/

/

SM

60 /

/

/

/

/

/

/

/

/

/

MC03

/

/

/

/

/

TC 35. 97 40

/

3.8m 3 .5m 3.4 m

/

/

/

2.5m SHARED PATH

/

/

2.5m

OXLEY RIVULET UPGRADE DESIGNED BY CARDNO STANTEC

/ / / / / /

/ / / / /

/

/ / / / / /

/ / / / / /

/ / /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-002

B

Mar 06, 2024 - 9:15am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

/ / / /

/ / /

ADJOINS SHEET 3

0.00

/

/

/

/

/

/

/

/

/

/

/

/

HILDE

ADJOINS SHEET 1

KG

/

/

/

/

/

/

R STR

20 KG

/

EET

/

/

/

/

/

/

/

/

/

/

MAKE SMOOTH CONNECTION WITH EXISTING PATH


/

/

/

/ /

/

/

LEGEND

/

/

/

/

/

ADJOINS SHEET 5

/

/

/

/

160

/

/ /

/

/

/

/

0.000

/

/

/

/

/

/

/

/

/

0 65.0

/

/

ADJOINS SHEET 5 /

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

/

ROAD CONTROL LINE

/

/

/

/

/

/

/

/

/ /

/

/

CONSTRUCT NEW PROPERTY ACCESS AND GATE. REFER C106-601 FOR DETAILS

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

CONSTRUCT NEW PROPERTY ACCESS AND GATE. REFER C106-601 FOR DETAILS

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

180

MCXX

HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/

200

/

/

/

/

/

/

/

KG

/

/

/

/

/

/

SM

/

/

/

/

/

/

/

/

/

SF

220

/

/

/

/

SF

/

/

/

/

/

/

SF

/

/

/

/

/

/

/

/

/

/

HERBERT RIVULET UPGRADE TO BE DESIGNED BY CARDNO STANTEC

KIRKHAM LANE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

RKG

/

1.8m /

/

/

3.5m /

MERGE BATTER TO HEADWALL CONSTRUCT SM KERB 5m FROM MEDIAN NOSE AND TRANSITION FROM SF TO SM OVER 3m

/

/

/

3.2m 3.5m 3.5m

/

/

/

/

/

66.00

/

/ / / / / /

/

/

/

/

/

/

/

/

/

/

/

/ / /

DESIGN CONTOURS - MAJOR

/ /

240

/

/

KG

/

/

/

/

/

/

/

/

/

/

86

/

/

/

/

/

/

MONOWILLS PEDESTRIAN FENCE

DESIGN CONTOURS - MINOR

/

/

/

/

/

1.8m 6.0m 3.2m 3.5m 3.5m 3.5m VARIES

EXISTING CONTOURS - MAJOR

800

780

760

740

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SM

SF

SF

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

KG

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

KG

/

/

/

/

/

/

/

STORMWATER EASEMENT SEWER EASEMENT

SF SF

3.5m3.5m 3.5m

/

/

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

KG /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

KG

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

2.5m SHARED PATH

40.00

3.5m 3.5m 3.4m 1.8m

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MONOWILLS PEDESTRIAN FENCE

/

/

/

/

CONSTRUCT NEW ROADSIDE DRAIN AT MIN 0.3%

/

TCS CONTROLLER - REFER PLINTH DETAIL ON DRAWING C106-701 DIVERSION CHANNEL 2

66.00

2.5m SHARED PATH

/

/

0.5m

20

"KIRKHAM PARK" SIGN AND GARDEN TO BE RELOCATED T.B.C BY CAMDEN COUNCIL LANDSCAPE ARCHITECTS

/

/

/

27SM 8.06 0.0SM 0 TC 0.05

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

66.00

/

/

/

/

/

KG

/

SM

/

/

/

/

SF

/

/

/

/

/

SF

SM

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/

SM

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

1.8m 3.5m 3.5m 3.5m 3.2m 3.5m 3.5m 2.5m 5.5m

/

/

/

/

/ /

5.1m 3.5m 3.5m 3.2m 3.5m 3.5m 3.5m 1.8m

/

/

/

/

/

720

/ /

/

/

/

/

/

/

/

.00

/

/

/

/

73

/

/

/

/

.00

/

/

/

/

72

/

/

/

/

/

/

/

/

00

/

/

/

/

/

71.

/

/

/

TC 269.56

/

00

/

/

/

/

70.

/

/

/

/

/

/

00 69.

/

/

/

.00

/

/

/

/

/

68

/

/

/

/

.00 67

CAMDEN VALLEY WAY

/

/

/

/

KG

/

/

PROPOSED BOUNDARY

/

/ / / / /

/ / /

/

/

/

/

/

EXISTING CONTOURS - MINOR EXISTING BOUNDARY

3.5m 3.5m 3.5m

/

/ /

/ / / / / /

700

/

/

/

255.48 257.25 260

/

SM

SM

/

640

/

/

/

/

/

MCB1

680

/ / /

660

/

/

/

/

/

MCB1

/

86

671.96 CT 674.84

/

/ / / / /

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

/

/

667.41

/

/

/

/

/

/

/

/

MERGE BATTER TO HEADWALL

/

/

/

/

/

/

/

1.2m FOOTPATH

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD

KERB RAMPS TO R0300-11 AT TCS INTERSECTION

66.00

LK

CT 59.76 60

KG

SF

8.0m

.00 LK

68

.00

30

40

68.00

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 1cm at full size

TC 127.23

50 metres

/

20

/

10

ADJOINS SHEET 6 /

5

120

/

0

8.0m

68 .00

40

73 .00

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

72 .00

TIERED SANDSTONE BLOCK RETAINING WALL REFER RETAINING WALL PLAN AND DETAIL

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

8.0m

100

3.8m2.5m

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-003

B

Mar 06, 2024 - 9:15am

ADJOINS SHEET 4

SF

KG

LIZ KERNOHAN DRIVE

.00

ADJOINS SHEET 2

1.2m FOOTPATH

TC 46.97

0

80

3.5m 3.5m 3.2m

ADJOINS SHEET 6

-1

MCA1

72

20

67.00

2.5m SHARED PATH

67

0.00

4.5m

67 .00

HERBERT RIVULET UPGRADE TO BE DESIGNED BY CARDNO STANTEC

DIVERSION CHANNEL 1

.00

4.5m 3.5m 3.5m 3.4m 4.5m 1.8m

2.5m

71

EXISTING CYCLEWAY BRIDGE (NOT SURVEYED). TO BE DEMOLISHED. TO BE CONFIRMED BY COUNCIL

Issue

.00 70

BARRIER KERB (SM)

MERGE BATTER TO HEADWALL


LEGEND ADJOINS SHEET 3

0.000

ROAD CONTROL LINE

MCXX

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

RKG KG SM SF

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD DESIGN CONTOURS - MAJOR

86

1m

/ /

//

//

//

//

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

PROPOSED BOUNDARY /

STORMWATER EASEMENT SEWER EASEMENT 79. 0

0

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / /

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

/

/

/

/

/

ADJOINS SHEET 3

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

.00

/

/

/

/

2m

KG

/

/

/

78

.00

.00

73

.00

74

00

.00

77.

76

75

CAMDEN VALLEY WAY

/

/ / /

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-004

B

Mar 06, 2024 - 9:15am

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

3m 3.5m 3.5m

KG

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

EXISTING CONTOURS - MINOR EXISTING BOUNDARY

945.79

MCB1

EXISTING CONTOURS - MAJOR

86

MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT

940

920

900

880

TC 864.55

860

840

820

800

DESIGN CONTOURS - MINOR


LEGEND 0.000

ROAD CONTROL LINE

MCXX

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

RKG

MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT

KG SM SF

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD

0.00 / /

/ /

/ / /

DESIGN CONTOURS - MAJOR

/

/

86

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

DESIGN CONTOURS - MINOR

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/

EXISTING CONTOURS - MAJOR

/

/

86

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

20

/

/

/

/

/

/

/

/

/

EXISTING CONTOURS - MINOR

/

/

/

/

/

/

/

/

/

/

/

/

EXISTING BOUNDARY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

PROPOSED BOUNDARY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/

STORMWATER EASEMENT

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

40

/

/

/

/

/

/

/

/

/

SEWER EASEMENT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

2.0m 1.0m /

/

60

/ /

2.0m 1.0m

/

/

/

/

/

3.5m

/

/

/

/

/

3.5m

/

/

/

/

/ / / / / / / / /

/ / / / / / / /

/ /

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

0 K64.0IR KHAM LANE

/

/ /

/ / / / / / / / / /

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

80

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

120

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

6

/

/

5.00

/

/

/

/

/ /

/

/

/

/

160

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-005

B

Mar 06, 2024 - 9:15am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

/

140


8.0m

68

LK

68 .00 .00

ROAD CONTROL LINE

120 MCXX

ROAD CONTROL LABEL

/

TC 46.97

ADJOINS SHEET 3 73 .00

68.00

40

0.000

72 .00

ADJOINS SHEET 3

LEGEND

/

/

TC 127.23

NEW DESIGN

/

/

/

/ /

/ /

/

/

/

/

/

/ / /

/

/ /

/

/

/

EXISTING SURVEY

/

/

/ /

/

/

/

/

/

/ / /

/ /

/ /

/

/

/

LYNDSAY DYNAN 110 LODGES ROAD DESIGN

/

/

74.00

75.00

76.00

/

6.7m

/

/

/

/ /

69

.00

140

/

69 .0 0

60

/

/

HERBERT RIVULET UPGRADE TO BE DESIGNED BY CARDNO STANTEC

LOT REGRADE

/

7

/ /

3. 0 0

/ /

/ /

/

68.00

/

HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

/ /

/

/

/

/

/

/

6.7m

/ /

/

/

/ /

/ /

/ /

/ /

/ /

RKG

/ /

160

/ /

/ /

/

/

/

/

/

70.0 0

/ /

/ /

KG

/ /

/

80

/

/

/

/ /

/ /

/

6.7m

/

SM

/ /

/

/

/ /

/ /

/

73

/ /

SF

/

/

/ /

.00

MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT

/ /

/ /

/

/

/

/

180

/

7 0. 00

1.2m FOOTPATH /

/

/ / /

/ /

/

/

/ /

/

/

74.0

/

/

/

/

/

0

/

/

6.7

/

53

/ /

/

m

/

/

/

/

/

/

LOT REGRADE

/

71.00

/

00

/

69.0

0

/

/

/

/

/

/

/ /

/ /

MCA1

/ /

/

/

/

71.00

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD

/

0 201. 0 2 T C

/

70.

00 68. 00 67.

100

/

KG /

/

/

/

/

DESIGN CONTOURS - MAJOR

86

/

/ /

/

/

/

/

/

/

/

/

SF

/

/

/

/

/

/

/

/

/

/

60

/

8709.00

/

/

/

/

/ / /

/

/

/

/

/ /

90. 08

/

/ / / / /

/

/

/

/ /

/

/

/

m 6.7

/

EXISTING BOUNDARY

/ /

G

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

STORMWATER EASEMENT

/

0

/

/ /

/

m 4.7

/

/

/

S R 0 GE 26 R E IT B EIN IRCU H R C

/

/

/

0

/

G RK

.3m

73 .0

/

E IV

/

00 73.

PROPOSED BOUNDARY

/

RK

m3

DR

m 8.0

/

SEWER EASEMENT

/ /

.00 73

73.00

/

/

0.0

/

/

/

/ / /

/ /

/

EASEMENT AND EXISTING SERVICES AND DRAINAGE TO BE EXTINGUISHED.

/ /

/ / /

/

73.00

73.00

/ / / / / / /

/

m 6.7

/

0

/

0

28

/

18

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

/

0

/

3.3

/

/

3 9.7

24

/

/

m 6.0

/

AN

/

m 4.7

/

2

20

/

EXISTING CONTOURS - MINOR

/

OH RN KE 72.00

/

m 6.7

40 C 40 T

86

/

40

16

/

/ /

74.0

/ /

/ /

/ / / /

/

/

0

/ / / /

SF

0

30

/

1.2m FOOTPATH

/

/ /

m 6.0

/

/ /

/

/

/

/

/

m 6.7

m 4.0

/

/ /

/ /

m 6.0

/ /

/ /

/

/ /

/ /

/

/

/ / /

/ /

/

/

/ / /

/

/

/

/ /

/

/

/

.00 .00 69

/

/

/ / /

/

/

m 4.5

/

/

/

/

/

/

/

/

/ /

/

/

.60 2 0 32 C 32 T MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT

/

/

/ /

/

/

70

.00 .00 721

73

KG

0

20

0

.0 95

/

SF

2

m

4.5

/

m

KG

6.7

2.5m SHARED PATH HERBERT RIVULET UPGRADE TO BE DESIGNED BY CARDNO STANTEC

EXISTING CONTOURS - MAJOR

/

/

73.00

/

/

MC01

DESIGN CONTOURS - MINOR

/

/

72.00

/

LIZ

.59

/

/

/

/

/

TIERED SANDSTONE BLOCK RETAINING WALL REFER RETAINING WALL PLAN AND DETAIL

/

/

/

m 6.0

/

/

/

/

/

m 6.0

/

0 14

22

/

1 CT

/

/

KG

.54 4 3

6 4.4

/

m 6.7

/

SF

0 12

0

22

/ / / / / /

RB HE

/ / / / /

/ / /

0

/ / /

/ / /

8.0

/ / /

/

m /

/ /

22

/ /

ER

/

/ / /

0

/ /

74 .0

/ /

/

/

8.0

/ /

TR

/ /

m

/ / / / /

/

/ / / / /

IVU

/ / / / / / /

0

/ /

34

/

6.7

/

0

/ /

m

/ /

/ / / / / /

LE

/ / /

T

24

/ / / /

/ / / / /

/ / / / / / /

/ / / / / / / /

/ / /

/

m 6.7

/ / / / / /

ET

/ / / /

/ /

0

/ /

/ /

/ / / /

m

/ /

.00

74

S 360 DJOIN A

6.7

0 74.

/

2

2

/

.8 57

E SH

7

/ / / /

/ /

/ / / / /

/ /

/

SF SF

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

/

SM

380 KG

8.0m

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-006

B

Mar 06, 2024 - 9:15am

/

m 7.7

/

MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

ADJOINS SHEET 8

/

ROAD CONTROL LINE

MCXX

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN

/

/

/

/

40 41.00 CT 45.42

1.2m FOOTPATH

MC02

/

57.75 PROPOSED DRIVEWAYS

MAKE SMOOTH CONNECTION EXISTING PAVEMENT

0.000

REMOVE EXISTING PAVEMENT AND VEGETATE AND GRADE TO PROPOSED ROAD

/

GRIMES AVENUE

/

HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

58

C2 6.

/

KG

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

40

/

520

KG

/

.07

RK G

/

73.00 5

SM

.73

4.5

MONOWILLS PEDESTRIAN FENCE

CT

54 8

m

SF

/

/

/

/

/

0.0

/

/

/

2.5m SHARED PATH

/

/

/

0

480

/

SF

/

.5m

LK

KG

/

m3

LK

/

00 73.

/

498 TC 500

20 3.5

/

527.72

T

MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT

RKG

/

56 0

/

/

/

/

/

/

/

460

SF /

/

/

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD

/

KG

/

/

/

/

MAKE SMOOTH CONNECTION TO EXISTNG ROAD (CONSTRUCTED BY PRIVATE DEVELOPMENT

/

/

/ / / / /

m

/

58 0

6.0

/ / / /

.00 73

/

m 3.0

/ /

m

/

6.0

/ /

DESIGN CONTOURS - MINOR

/

/

/

MCA1

MK

/ / / /

0

/ / /

/

m

EXISTING CONTOURS - MINOR

73.00

/ /

/

2.5m SHARED PATH

EXISTING BOUNDARY

BREAK IN MEDIAN TO ALLOW STORMWATER BREAKOUT

/

6.7

60 0

/ / /

73.0

0

EXISTING CONTOURS - MAJOR

86

/

KG 73 .0

/

m 6.7

/

RN

N

E

MK

DESIGN CONTOURS - MAJOR

86

00

PROPOSED BOUNDARY

/

/

/

0 40

U B N I E

/ / /

6.7

4.0 0

SEWER EASEMENT

/ /

/

/

/

/

m

m

/ /

MK

/

/

6.7

/

/

m

MK

/

TRANSITION VERGE PROFILE FROM 2.5% TO -2.5% OVER 5m

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

64

/

8.0

0

/

/

/

m

/

BREAK IN MEDIAN TO MATCH EXISTING MEDIAN GAP

m 6.7

STORMWATER EASEMENT

62

/

/

/

/

62 0

/

MONOWILLS PEDESTRIAN FENCE

m 6 .7

RH

0

KG73.

.00

E K Z LI

A OH

IV R D

SF

1.0

38

/

420 .36 3 2 4 CT

SF

73

C S R E RG

m 6.7

m 6.0

IT U IRC

m 6.0

m 4.0

440

m 6.0

/

/

/

/

36 0

/

/

/

/

/

KG

/

/ /

0

/

/

/

m

66

/ /

6.7

2.5m SHARED PATH

SM

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

720

700 /

/

/

/

/

/

/ / / / / / / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SF

MCA1 /

/

/

/

/

m

679.

/

/

/

/

680

64

/

MAKE SMOOTH CONNECTION TO EXSITNG ROAD (CONSTRUCTED AS PART OF PRIVATE DEVELOPMENT /

SF

PROPOSED SHARED PATH TO MATCH EXISTING LEVELS

/

T6 EE SH

KG

/

S IN

73 .00

JO AD

m 8.0

/

7.7

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/ /

/ /

/ / /

/ /

/ /

/ /

/

/

/

/

/

/

/

/

74

/

/ /

/

/ / /

/

/

/

/

/

/

.00

/ /

/

/

/

/

/

/

/ /

/

/

6.7 m

/

/

/

/

/

/

/

/

6.7 m

/

/

/

/

/

EXTEND PATH TO EXISTING KERB RAMP CONSTRUCTED BY PRIVATE DEVELOPMENT

/

/

/

/

/

.00

/

/

/

/

/

/

/ /

/ /

74

/ /

/

/ /

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

.82

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

25 7 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

24 0

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

UL E

6 ET

T

E SH

5

10

20

30

40

50 metres

RI V

0

BE RT

NOT FOR CONSTRUCTION Client

HE R

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

North

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-007

B

Mar 06, 2024 - 9:15am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 9

ADJOINS SHEET 7

0.000

ROAD CONTROL LINE

MCXX

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

RKG

RW RW

KG SM SF

RW

RW

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD DESIGN CONTOURS - MAJOR

RW

86

DESIGN CONTOURS - MINOR EXISTING CONTOURS - MAJOR

86 LOCALLY STEEPEN BATTER TO 1V:2H TO REDUCE IMPACT OF EXISTING TREES

EXISTING CONTOURS - MINOR EXISTING BOUNDARY PROPOSED BOUNDARY STORMWATER EASEMENT 2.5m SHARED PATH

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

4.5m

/

/

/

SF

00

LIZ KERNOHAN DRIVE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1040

1020

1000

980 /

4.5m

/

KG

/

/

960

940

920

879.00 880

870.98

860

840

/ / / / / /

/

/

/ /

/

/

6.0m

/

800

780

760 /

/

720

740 /

/

/

/

/

87. 00

/

/

/

/

00

/

/

/

/

87.

/

/

/

/

0

/

/

/

/

86. 0

/

/

/

/

00

/

/

/

/

86.

/

/

/

/

00

/

/

/

/

85.

/

/

/

/

00

/

/

/

/

85.

/

/

/

/

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

KG

SF

0

/

/

/

/

84.0

/

/

/

/

00

/

/

/

/

84.

/

/

/

83.0 0

/

/

/

/

0

/

/

/

83.0

/

/

/

82.0 0

/

/

/

00

/

/

/

82.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

81.0 0

/

/

/

/

/

/

00

/

/

/

/

/

81.

/

/

/

/

/

80.

/

/

/

/

/

/

/

/

/

00

/

/

/

/

/

80.

/

/

/

/

/

.00

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

79

/

/

820

MCA1

900 900.58

SEWER EASEMENT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

4.5m

6.0m

SF

/

/ / / /

/ /

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-008

B

Mar 06, 2024 - 9:15am

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

ADJOINS SHEET 9

ADJOINS SHEET 7

MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT


LEGEND ADJOINS SHEET 8

0.000

ROAD CONTROL LINE

MCXX

ROAD CONTROL LABEL NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET AND OXLEY RIVULET DESIGN BY CARDNO STANTEC ROLL KERB AND GUTTER TO CCC STANDARD KERB AND GUTTER TO CCC STANDARD KERB ONLY TO CCC STANDARD MOUNTABLE KERB TO CCC STANDARD POST AND RAIL PEDESTRIAN FENCE

RKG KG SM SF

MONOWILLS PEDESTRIAN FENCE TO MANUFACTURER STANDARD

LODGES ROAD

BLOCKWORK RETAINING WALL 1.5m MAX REFER RETAINING WALL PLAN AND DETAILS

DESIGN CONTOURS - MAJOR

86

DESIGN CONTOURS - MINOR EXISTING CONTOURS - MAJOR

86

EXISTING CONTOURS - MINOR EXISTING BOUNDARY

MAKE SMOOTH CONNECTION TO EXISTING PAVEMENT /

/

PROPOSED BOUNDARY

/

/

/

/

STORMWATER EASEMENT

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

1184.83

1180

/

/

/

/

/

/

/

/

1160

/

/

/

/

/

/

/

1140 1144.00 CT 1145.93

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

91

00

.00

92.

91.00

00

89. 00

0

88. 0

6.0m

/

90.

00

0

SF

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

GENERAL ARRANGEMENT PLAN SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C105-009

B

Mar 06, 2024 - 9:16am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C105-00.dwg

4.5m

6.0m

.00 92

87. 00

LIZ KERNOHAN DRIVE

/

/

00

90.

89.

4.5m

/

EXISTING TREE TO BE RETAINED SUBJECT TO ARBORIST ASSESSMENT

/

/ /

SEWER EASEMENT

/

/ /

/

/

/

0 88.

00

87. KG

/

/

CT 1 TC 1 112.23 113.9 9 1120

1100

/

/

/

/

/

MCA1 /

40

49.00

TC 1091.21

1080

/

20

/

1060

/

0.00

/

1040

2.5m SHARED PATH


200

183.84 CTP 183.87

180

170.08

160

140

120

100

TC 84.03

80

60

40

20

L 84.03

CAMDEN VA

LLEY WAY R -700.00 L 99.84

MCB1

10 10

PROPOSED PATH CONTROL ALIGNMENT

MCB1

ROAD CONTROL ALIGNMENT MARKER

MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. 0 R -130.0 PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY L 36.20 AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

P

55°46'37"

PROPOSED ROAD CONTROL ALIGNMENT

CT

0.00

ADJOINS SHEET 2

LEGEND

12

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-001

B

Mar 06, 2024 - 9:16am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

.80 SCALE 1:500 @ A1 SCALE 1:1000 @ A3


CAMDEN VALLEY WAY 48°11'4" L 108.34

L 11.7

0 R 30.0 7

80

CT 71.44 L3

500

MP11

L 1.72 L 11

.08

MCAK

60 2.50

1 6 .37

10

PROPOSED PATH CONTROL ALIGNMENT

MCB1

ROAD CONTROL ALIGNMENT MARKER

MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

L 35.47

R -150.00

228°20'51" R 1

P CT

0.00 TC 1.72

.80 12

MP31

CT 220.1 2220

185.10

L 31.39

'26" °48 203 .66 L 13

.57

L 35.02

00

318°47'3"

1

1

R

L 203.56

R -30.

12.8

7

9

L 15.42

26.4

3.2

R 603.50

0.00

CT 20 TC

38.24

-2

49°4'5"

L 12.8

100 102.83 0 R -130.0 L 36.20

R 1000.00

200

9'5" 31°3 19 L 16.

480

460

440

MCB1

420

400

380

360 CT 360.02

TC 344.60

340

320

297.63 300

289.31

280

260

240

236.26

220 220.07 CT

200

183.84 CTP 183.87

180

MCB1

PROPOSED ROAD CONTROL ALIGNMENT

10

ADJOINS SHEET 3

ADJOINS SHEET 1

LEGEND

TC 35. 97 40 MC03

20

EET 7

ADJOINS SHEET 3

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

10

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-002

B

Mar 06, 2024 - 9:16am

5

HILDE

0.00 0

L 35.9

R STR

ADJOINS SHEET 1

332°20

'0"

20 SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND

160

ADJOINS SHEET 4

ADJOINS SHEET 2

KIRKHAM LANE

180

200 MCAL

180

10

ADJOINS SHEET 5

160

PROPOSED ROAD CONTROL ALIGNMENT

10

ADJOINS SHEET 5

PROPOSED PATH CONTROL ALIGNMENT

MCB1

ROAD CONTROL ALIGNMENT MARKER

MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

MCA2

200

144°54'34"

L 119.32

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

220

220

PM25143 RL64.029

240

MCB1

800

780

760

740

720

700

255.48 257.25 260

680

671.96 CT 674.84

667.41

660

TC 269.68

20

L 4.76 L 4.41

0

L 19.04

L 73.36

MCAK

2205°4'47" R -100.0

500

CT 487.15

480

TC 468.11

460

440

420

400

CT 394.75

380

60

ADJOINS SHEET 2

137°2'57"

100

0

5

10

20

30

40

TC 105.19

50 metres

ADJOINS SHEET 6

TC 127.23

NOT FOR CONSTRUCTION Client North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 1cm at full size

120

100

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

0

80

L 67.47 137°1'43"

L 64.11

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

-1

MCA1

80

ADJOINS SHEET 6

Issue

CT 59.76 60

ADJOINS SHEET 4

40 CT 41.08

LIZ KERNOHAN DRIVE

MCAJ

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

360

340

320

CTP 308.14

300

280

TC 270.57

260

240

CT 220.1 2220

25

0.0 TC 0 2.38

CT 15.69

20

40.00

20

40

TC 53.04

CT 57.80 60 62.21

R -500.00

L 60.62

L 59.72 R -506.00

MP12

520

L 86.61

L 66.18

R -350.00

6"

L 37.57

47°47'33"

3°1 2'4

R -5005.00

44°40'35"

L

R -596.50

278.06 0.00 TC 0.05

227°48'19"

L 50.45

CAMDEN VALLEY WAY

L 189.71

L 37.35

L 111.26

47°47'36"

2.38

52°23'35"

TC 269.56

R -30.0 0 L 13.30

R -5000.00

R -500.00

CAMDEN VALLEY WAY

L 8.50 R -50514 .003°53'32"

L 8.60 L 0.30

-19. TC 27 8.53 27 84

STN RL67.377

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-003

B

Mar 06, 2024 - 9:17am

260

640

MCB1

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

240

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.


L 81.25

CAMDEN VALLEY WAY

585.88

580

560

540

520

10 10

ROAD CONTROL ALIGNMENT MARKER

MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

ADJOINS SHEET 3

TC 553.33

L 66.18

MCAK

MCB1

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

L 32.55

PROPOSED PATH CONTROL ALIGNMENT

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-004

B

Mar 06, 2024 - 9:17am

R 500.00

R 598.50 44°40'35"

945.79

PM56874 RL79.025

PROPOSED ROAD CONTROL ALIGNMENT

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

940

MCB1

920

900

880

860

840

820

800

TC 864.55

ADJOINS SHEET 3

LEGEND


0.00

30.00

40

40 R 645.83

L 36.56

60 MCA2

60

MCAL

80

80

6"

148°16'3

L 48.54

KIRKHAM LANE

100

TC 115.1 0 120

10

PROPOSED PATH CONTROL ALIGNMENT

MCB1

ROAD CONTROL ALIGNMENT MARKER

MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

20

CT 66.56

PROPOSED ROAD CONTROL ALIGNMENT

10

LEGEND

100

120

140

CT 150.36

160

160 ADJOINS SHEET 3

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

ADJOINS SHEET 3

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-005

B

Mar 06, 2024 - 9:17am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

144°54'34"

L 26 56 R -600.09. 0

L 35.26

140


LEGEND

10

ADJOINS SHEET 3 PROPOSED ROAD CONTROL ALIGNMENT

10

ADJOINS SHEET 3

PROPOSED PATH CONTROL ALIGNMENT

120

100 TC 105.19

TC 127.23

140 120

160 0 11.5 R -1 .30 L2704.00 R -1 .92 L 79

140

180

MCB1

ROAD CONTROL ALIGNMENT MARKER

MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

53

0 201. 0 2 T C

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

R E RG T E B UI N I C E RH CIR

6 4.4

L 49.49

0

24

.11

.73

9 24

0

CT

5 18

R 43.00

20

1

80

40 C 40 T

22

90. 08

22

60

S

0

MCAJ

.59

160

8709.00

MCA1

1

0.0

"

'12

2 5°3

MC01

9 0.50 4 L

26

3" 2'1 °5 7" 98 1.0'13 1°252 .16 9L 8 21 L1

0

28

LIZ

0

KE

2

.0 95

0

AN

OH RN

30

E

IV

DR

.60 2 0 32 C 32 T

0

34

00 14. R2 76 00.

L1

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

.00 10 3 8.4 L4

S 360 DJOIN A

7

380

SS167728 RL73.670

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-006

B

Mar 06, 2024 - 9:17am

R2

ET

E SH


R -35. 00 L 18.8 4

40 41.00 CT 45.42

0

56 0

460

58 0

440 420 .36 3 2 4 CT

0

4.7

60 0

R

62

38

IT

CU 0

N

E

62 0

CIR

E K Z LI

HA O N

IV R D

19

8°

25 '11 30 " .91

64

L1

0

0 40

S ER

RG BE

MCA1

4.0 0

L7

SS167728 RL73.670

720

700

64

680

T6 EE SH

679.

S IN

66

0

36 0 JO AD

0 4.0 1 2 .76 R 00 1 L

3

L4

8.4

21

0.0

0

MCA1 R

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

CT

54 8

.73

540

32' 41" L2 6.5 8

93°

480

0.0

EIN RH

1

MP01

S IN

JO AD

ADJOINS SHEET 8

MCAJ

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

527.72

520

.07 498 TC 500

20

"

ROAD CONTROL ALIGNMENT MARKER

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

'51

50 25°

MCB1

SS167729 RL73.628

T

L 50.66

PROPOSED PATH CONTROL ALIGNMENT

6 ET

E SH

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-007

B

Mar 06, 2024 - 9:17am

58

C2 6.

R 40.00

10

MC02

PROPOSED ROAD CONTROL ALIGNMENT

10

ADJOINS SHEET 8

GRIMES AVENUE

L 12.33

57.75 62°42'23"

LEGEND


152°38'50"

LIZ KERNOHAN DRIVE

L 190.63

152°38'5" L 29.60

152°38'58" L 191.34

SS196765 RL82.677

SS185034 RL79.011

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

10 10 MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

NOT FOR CONSTRUCTION North

-1

ROAD CONTROL ALIGNMENT MARKER

50 metres

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

MCB1

ADJOINS SHEET 9

ADJOINS SHEET 7

SS185033 RL75.497

PROPOSED PATH CONTROL ALIGNMENT

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

MCA1

PROPOSED ROAD CONTROL ALIGNMENT

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-008

B

Mar 06, 2024 - 9:17am

1040

ADJOINS SHEET 9

1020

1000

980

960

940

920

900 900.58

879.00 880

870.98

840

820

800

780

760

740

720

860

ADJOINS SHEET 7

LEGEND


L 21.01

1184.83

1180

4'2" R -94.50

152°42'17"

L 31.94

L 38.90

10 10

ROAD CONTROL ALIGNMENT MARKER

MP01

FOOTPATH / SHARED PATH ALIGNMENT MARKER

SS167729 RL73.628

SURVEY MARKER TO BE REMOVED

SS167728 RL73.670

SURVEY MARKER UNDER THREAT

SS185033 RL75.497

SURVEY MARKER SAFE

ADJOINS SHEET 8

7

MCB1

DISCLAIMER FOR PLAN OF SURVEY INFRASTRUCTURE “SURVEY INFRASTRUCTURE” IS DEFINED AS PERMANENT SURVEY MARKS AND CADASTRAL REFERENCE MARKS THAT REFERENCE THE NEW SOUTH WALES CADASTRE, BOTH BEING DEFINED IN THE “SURVEYING AND SPATIAL INFORMATION REGULATION”. THIS DRAWING HIGHLIGHTS SURVEY INFRASTRUCTURE IN THE GENERAL VICINITY OF THE PROPOSED CONSTRUCTION FOOTPRINT. THE PURPOSE OF THIS DIAGRAM AND THE ASSOCIATED SURVEY INFRASTRUCTURE SCHEDULE IS TO ASSIST THE CONTRACTOR TO CARE, PROTECT AND PRESERVE SURVEY INFRASTRUCTURE AS REQUIRED UNDER THE LAW IN NEW SOUTH WALES. THE SURVEY INFRASTRUCTURE MARKS SHOWN HAVE BEEN SURVEYED AND/OR CALCULATED FROM THE DEPOSITED PLANS AND THE STATE CONTROL NETWORK AND SHOULD BE VERIFIED FOR COMPLETENESS. THE SUPPLIED COORDINATES VARY IN ACCURACY AND SHALL BE VERIFIED BY A LAND SURVEYOR, AS DEFINED UNDER THE SURVEYING & SPATIAL INFORMATION ACT, PRIOR TO THE COMMENCEMENT OF ANY CONSTRUCTION ACTIVITY WITHIN OR NEAR THE CONSTRUCTION LIMITS DEPICTED. PRIOR TO COMMENCEMENT OF ANY CONSTRUCTION ACTIVITIES THAT MAY AFFECT THE SURVEY INFRASTRUCTURE, CONTACT THE DEPARTMENT OF CUSTOMER SERVICE, SPATIAL SERVICES TO OBTAIN THE SURVEYOR GENERAL'S AUTHORITY TO DISTURB THOSE SURVEY MARKS FORMING PART OF THE SURVEY INFRASTRUCTURE AFFECTED BY THE WORKS. COMPLY WITH SURVEYOR GENERAL'S DIRECTIONS NO.11 "PRESERVATION OF SURVEY INFRASTRUCTURE". PERMANENT SURVEY & CADASTRAL REFERENCE MARKS ARE PROTECTED UNDER SECTION 24 OF THE SURVEYING AND SPATIAL INFORMATION ACT. REFER TO AN APPLICATION UNDER CLAUSE 90 OF THE SURVEYING AND SPATIAL INFORMATION REGULATION FOR THE PROCESS TO REMOVE OR OBLITERATE MARKS.

172° L 1.7

PROPOSED PATH CONTROL ALIGNMENT

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-00.dwg

R 62.00

1160

1140 1144.00 CT 1145.93

CT 1 TC 1 112.23 113.9 9 1120

MCA1

PROPOSED ROAD CONTROL ALIGNMENT

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ALIGNMENT CONTROL PLAN SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-009

B

Mar 06, 2024 - 9:17am

LIZ KERNOHAN DRIVE

1100

TC 1091.21

1040

1060

1080

ADJOINS SHEET 8

LEGEND


10

LEGEND PROPOSED MEDIAN CONTROL ALIGNMENT

MA01

MEDIAN ALIGNMENT MARKER

TC 6.40

T

TC 30.09

.59 17 CT 20

CT 40.28 CT 24.69

49

6

39.6

83

1. TC 3

CTP 40

40 40.05 TC

TC 24.14 MA22

CAMDEN VALLEY WAY 3. CT 2

5 33.7 T C

CT 42.00

TC 15.95

CAMDEN VALLEY WAY

20 TC 21.84

3.2 C3

7

CT 7.96

MA23

CT 31.65

20

TC 5.07

CT 13.31 CT 9.39

TC 13.16

MA24

CTP 9.2 5

INSET A MA25

15.55

INSET A

1

12 .4

MA25

EET

0.00

R STR

MA25

CT 2.6

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-02.dwg

0

CT 7.15

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

TC 5.4 7

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

MEDIAN CONTROL PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-021

B

Mar 06, 2024 - 9:18am

HILDE

5


LEGEND

10

ADJOINS SHEET 3

KIRKHAM LANE

ADJOINS SHEET 3

PROPOSED MEDIAN CONTROL ALIGNMENT

MA01

MEDIAN ALIGNMENT MARKER

65.18

66.73

60 TC 77.31 80

88.27

40

100

20

MK11

120

TC 92.90

TC 79.84 80 4 .8 1 8 T C

60

40

20

CTP 189.45

CTP 99.10

80

100

60 CTP 62.02

CT 7.35

134.81

CTP 50.03

CT 93.82

100

120

140

MA12

160

TC 179.28 180

CTP 186.63

CTP 101.93

20

CTP 37.13 CT 39.100 4

TC 49.13

CAMDEN VALLEY WAY

MA13

131.95

CAMDEN VALLEY WAY

355.83 0.00

353.00

340 MA01

MA0J

20

320

TC 314.46

LIZ KERNOHAN DRIVE

CT 38.40 40

300 280

80

260 ADJOINS SHEET 4

ADJOINS SHEET 4

TC 249.73 CT 252.65 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

TC 105.34

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

100

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

MEDIAN CONTROL PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-022

B

Mar 06, 2024 - 9:18am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-02.dwg

60


LEGEND ADJOINS SHEET 2

ADJOINS SHEET 2 10

260 100

PROPOSED MEDIAN CONTROL ALIGNMENT

TC 105.34

MA01

MEDIAN ALIGNMENT MARKER

TC 249.73 CT 252.65 CT 238 240 .28

120

CTP 23

2.38

220 140

200

160

.59

18

0

TC

17

0.3

MA0J

MA01

79 1 CT 80 1

ER G ER IT B IN CU E RH CIR

5

16

0 20

S

0

14

0

22

0

12

0

24

0

LIZ

0

10

0

AN

OH RN

KE

26

DR

0

80

E

IV

28

.65 1 0 0 30 C 3 T

60

CT

0 ET

5

.23

20

340

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-02.dwg

48

NS

JOI AD

E SH

CT

.58 34.800 0

P1

3 1.0

1 CTP

24.27

CT T 1. C 1.3245

MA06

5

120 23.45 1 CTP

S OIN

EET

SH

J

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

AD

50 metres

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

C

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

5.02 2 1 TP

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

MEDIAN CONTROL PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-023

B

Mar 06, 2024 - 9:18am

40

32


PROPOSED MEDIAN CONTROL ALIGNMENT

MA01

MEDIAN ALIGNMENT MARKER

.93 5.5 4

01 10

P1 CT

60

CTP 75

CT

15 3.3 3

CT 0 16

C

1 TC 40 14 2.3 6

40

55 7. T2

12 0

20

7 9.0 0 5 TC 158.4 60 CT

43

20

56.

TC

MA06

40

6

48 .6

P

CT

P CT 60

.86 154 .86 CTC 156 T

3

IT

48 92. CT 6.03 9

100

TC

CU

CT

5

.8 47

P1

C .20

T6 4

3.4

CIR

80 .95 CTP 82

7 TC

S ER .02

80

MA02

.26 153 TC 64.21 CT

RG BE 5 12

3

T 1 C CT00 96.8 P 4 .36

10 0

28

12.

.84

80 CTP 80

100

1 CT

N

E

120

N

140

EIN RH 27 24. P1 CT

0

12

MA03

18

0

CT

CT 1.2 TC 1.345

0

20

0

CT P

0.0

T4 EE SH

34

S IN

2 20 00 2.2 7

JO AD

.58 8 34 .00 0

20

.45

23

P1

MA01

6 0.6.66L 6 CTC 62 T

ER K IZ

A OH

IV R D

CT CTPP 76.70 79.02

CT P 1 01 .1

3 40C 40.9 T

.95

MC02

10

ADJOINS SHEET 6

GRIMES AVENUE

LEGEND

11 .03 MA0J

32

0

40

S IN

JO AD 4 ET

E SH

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

MEDIAN CONTROL PLAN SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-024

B

Mar 06, 2024 - 9:18am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-02.dwg

8.2 3

ADJOINS SHEET 6

CT 4


10

ADJOINS SHEET 7

ADJOINS SHEET 5

LEGEND PROPOSED MEDIAN CONTROL ALIGNMENT

MA01

MEDIAN ALIGNMENT MARKER

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-02.dwg

ADJOINS SHEET 7 0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

MEDIAN CONTROL PLAN SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-025

B

Mar 06, 2024 - 9:18am

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

160

140

120

100

80

60

40

34.36

20

4.76

ADJOINS SHEET 5

LIZ KERNOHAN DRIVE

0.00

MA04


10

ADJOINS SHEET 6

LEGEND PROPOSED MEDIAN CONTROL ALIGNMENT

MA01

MEDIAN ALIGNMENT MARKER

CTP 269.98 CT 271.34 271.47

260

240

CT 2 TC 24488.15 CTP 2 .81 51.95

0.00 CTP 1.38

CT 20 P 19.81 22.89

LIZ KERNOHAN DRIVE

CTP 229.95

TC 224.99

200

180

160

220

MA04

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

MEDIAN CONTROL PLAN SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-026

B

Mar 06, 2024 - 9:18am

ADJOINS SHEET 6

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-02.dwg

MA05


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Des DRAI

Ex GAS

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 66.48 CH 248.61m

CREST RL 66.50 CH 234.61m VIP RL 66.50 CH 234.61m MC03 (RL66.50)(CH236.26)

VIP RL 66.50 CH 221.72m

VIP RL 65.85 CH 184.51m

SAG RL 65.92 CH 177.98m

VIP RL 66.99 CH 18.29m

Ex D

Des DRAI

G = 1.74%

L = 84.03

0.70

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-10.dwg

65.16 300

CAMDEN VALLEY WAY - MCB1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-101

B

Mar 06, 2024 - 9:18am

65.23 280

65.86

0.87

65.28 260

66.10

1.06

65.30 248.61

66.34

1.19

65.32 240

66.48

1.18

65.35 234.61

66.49

1.15

65.46 65.46 65.47 220 220.07 221.72

66.50

0.60 0.61 65.52 65.52 199.51 200

66.11 66.12

0.26 65.68 183.87

65.94

0.24 65.69 180

65.93

0.24 65.72 169.51

65.95

0.28 66.02 65.74 160

66.16

0.45

R = -130

65.71

65.57 120

L = 108.34

140

0.72

65.77 100

66.29

0.66

65.95 84.03

66.43

0.59

65.99 80

66.54

0.58

66.29 60

66.57

0.41

66.60 40

66.70

0.24

66.68 34.79

66.84

66.95

CHAINAGE

20

66.88

67.31 67.31 67.28

67.01

0.06

-0.00 0.00

EXISTING LEVELS

0 0.08 1.79

67.31 67.28

0.19

R = -700

DESIGN LEVELS

G = -1.22%

L = 16.19

HORIZONTAL GEOMETRY

CUT / FILL DEPTH

G = -0.13%

G = -0.69%

G = 0.01%

K = 12.34 L = 30

1.01 1.01 1.03

VERTICAL GEOMETRY

K = 31.13 L = 33

66.47 66.47 66.50

G = -1.75%

DATUM R.L 62


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Des DRAI

Ex GAS

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 65.13 CH 565.70m

SAG RL 65.25 CH 561.70m

VIP RL 65.23 CH 351.65m SAG RL 65.31 CH 353.11m

VIP RL 66.25 CH 453.70m CREST RL 66.18 CH 453.70m

Ex D

Des DRAI Des DRAI Des DRAIDes DRAI Des DRAI

DATUM R.L 61

G = -1.22%

G = 1%

L = 108.34

K = 16 L = 40

G = -1%

L = 203.56

0.40

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-10.dwg

65.24 600

CAMDEN VALLEY WAY - MCB1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 2 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-102

B

Mar 06, 2024 - 9:18am

65.06 585.7

65.64

0.37

65.02 580

65.43

0.34

0.36 0.34 64.90 64.91 560 563.58

65.25 65.25

0.47 64.86 545.7

65.33

0.54 64.85 540

65.39

0.75 64.84 520

65.59

0.96 64.83 500

65.79

1.16 64.82 480

65.99

1.26 64.84 468.7

66.10

1.31 64.85

66.16

1.20 1.21 66.10 66.11

460

64.94 420

64.90 64.90

64.94 400

438.7 440

0.98

64.95 380

65.91

0.77

65.00 366.65

65.71

0.56

65.02 65.02 360 360.02

65.51

0.38

65.08 344.6

65.38

0.31 0.31

65.11 65.10 336.65 340

65.33 65.33

0.26

65.12

CHAINAGE

320

65.34

EXISTING LEVELS

65.16

65.41 65.38

R = -5000

300

65.86

DESIGN LEVELS

65.61

0.70

CUT / FILL DEPTH

0.31 0.28

R = 1000

0.49

HORIZONTAL GEOMETRY

65.35

VERTICAL GEOMETRY

K = 15 L = 30

G = 1.5%

K = 13.54 L = 30


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex D

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 66.91 CH 684.29m

VIP RL 72.01 CH 780.63m

VIP RL 76.24 CH 874.56m

Ex GAS

Ex WATR

Des DRAI DesDes DRAI Des DRAI DRAI Des DRAI Des DRAI

DATUM R.L 62

K = 18 L = 68.4

G = 1.5%

VERTICAL GEOMETRY

K = 60 L = 48

G = 5.3%

G = 4.5%

G = 5.06%

L = 189.71

-0.18

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-10.dwg

CAMDEN VALLEY WAY - MCB1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 3 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-103

B

Mar 06, 2024 - 9:18am

77.71 900

77.53

-0.20 -0.20 76.72 76.72 880 880.03

76.52 76.52

-0.21 76.45 874.56

76.24

-0.17 75.96 864.55

75.79

-0.16 75.74 860

75.59

-0.12 75.28 850.43

75.16

-0.05 74.73 840

74.69

0.15 73.64 820

73.79

0.28 72.81 804.63

73.09

0.31 72.57 800

72.88

0.40 71.54 780

71.94

0.35 0.37 70.39 70.55

70.74 70.92

0.25 69.86

756.63 760

68.68 68.74 718.49 720

69.62

67.90 700

740

67.11 680

68.72 68.80

0.04 0.06

-0.07

66.91 674.84

67.84

-0.02

66.32 66.36 658.67 660

67.09

0.03

66.13 650.09

66.94

0.22 0.21

65.92 640

66.55 66.57

0.26

65.60

CHAINAGE

620

66.40

65.24

66.24

EXISTING LEVELS

600

65.64

DESIGN LEVELS

65.94

0.40

CUT / FILL DEPTH

R = 500

0.33

R = -5000

0.35

HORIZONTAL GEOMETRY


VIP RL 78.71 CH 923.42m VERTICAL GEOMETRY

G = 1.95%

G = 5.06%

DATUM R.L 75

K = 14 L = 43.47

-0.00 0.00

CAMDEN VALLEY WAY - MCB1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 4 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-104

B

Mar 06, 2024 - 9:18am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-10.dwg

79.14 79.15 79.15 79.14 79.15 945.16 945.79 945.85

79.03 79.04 940

CHAINAGE

920

900 901.69

77.71 77.78

EXISTING LEVELS

78.51

77.53 77.61

DESIGN LEVELS

78.42

-0.18 -0.17

CUT / FILL DEPTH

-0.01

R = 500

-0.09

HORIZONTAL GEOMETRY


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex GAS

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

(CH102.83) MCB1 (RL66.50)

VIP RL 66.50 CH 86.83m

VIP RL 66.24 CH 74.16m

VIP RL 66.68 CH 6.69m

SAG RL 66.29 CH 69.07m

Ex D

Des DRAI Ex WATR

L = 35.97

G = 0.02%

G = -0.65%

G = 2%

VERTICAL GEOMETRY

K = 7.55 L = 20

K = 14.42 L = 10

G = -1.34%

DATUM R.L 62

L = 31.39

0.93 1.18

HILDER ST - MC03 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS HILDER STREET - MC03 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-111

B

Mar 06, 2024 - 9:18am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-11.dwg

66.50 66.50 65.57 65.32 100 102.83

0.87 0.92 66.44 66.50 65.57 65.58 84.16 86.83

0.94 66.37 65.43 80

0.76 66.30 65.54 71.44

0.66 66.31 65.65 64.16

0.61 66.34 65.73 60

0.33 66.14 40

66.47

66.19 35.97

66.49

66.44 20

66.60

66.59

CHAINAGE

11.69

66.65

66.77 66.75

66.77 66.75

EXISTING LEVELS

0 1.69

DESIGN LEVELS

0.06

-0.00 0.00

CUT / FILL DEPTH

0.30

R = -150

0.15

HORIZONTAL GEOMETRY


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex D

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 66.38 CH 273.62m

VIP RL 66.16 CH 237.84m

VIP RL 63.98 CH 81.97m

Ex GAS

Ex WATR

Des DRAI Ex SEWR

G = 1.4%

K = 20 L = 8.87

G = 0.51%

VERTICAL GEOMETRY

K = 35 L = 28

G = 0.6%

K = 40 L = 35.45

G = 0.16%

DATUM R.L 61

L = 269.56

0.27

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-12.dwg

KIRKHAM LANE - MCA2 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS KIRKHAM LANE - MCA2 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-121

B

Mar 06, 2024 - 9:19am

66.12 278.06

66.39

0.70 0.68 65.65 65.67 269.19 269.56

66.35 66.35

0.97 65.32 260

66.30

1.10 65.15 251.84

66.25

1.26 64.89 240

66.16

1.29 64.68 223.84

65.97

1.27 64.64 220

65.91

1.13 64.50 200

65.63

0.93 64.42 180

65.35

0.76 64.32 160

65.07

0.59 64.79 64.21 140

0.39 64.13 120

64.51

0.18 0.18 64.05 64.05 99.7 100

64.23 64.23

0.06 63.94 80

64.00

0.04 63.89 63.85 64.25

63.87 63.83 60

63.77 63.72 40

63.66 63.64 20

CHAINAGE

63.57

EXISTING LEVELS

0

63.56

DESIGN LEVELS

0.02

-0.01

CUT / FILL DEPTH

0.04

R = -500

0.05

HORIZONTAL GEOMETRY


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex D

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 66.10 CH 53.84m

SAG RL 66.21 CH 38.02m

VIP RL 66.37 CH 9.12m

MCB1 (RL66.39) (CH0.00)

MC01 (RL73.35) (CH255.22) VIP RL 73.79 CH 257.44m

Ex GAS

Des DRAI

Des DRAI

Des DRAI

Ex COMS Des DRAI

Des DRAI

Des DRAI

Ex WATR

G = -0.62%

K = 10.01 L = 44

G = 3.78%

L = 0.05

L = 67.47

L = 121.07

0.14

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-13.dwg

73.80 300

LIZ KERNOHAN DRIVE - MCA1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-131

B

Mar 06, 2024 - 9:19am

68.94 280

73.95

4.81

68.71 260

73.75

4.71

68.24 240

73.42

4.70

67.77 220

72.95

4.57

67.52 207.44

72.35

4.38

67.35 67.39 200 201.53

71.90

4.27 4.28

66.98 180

71.62 71.68

3.88

66.84 160

70.86

3.27

2.58 69.35 66.77 140

2.11 68.87 66.76

66.75 120

127.23

1.85

66.69 100

68.60

66.63 80

67.84

1.15

0.45

66.60 75.84

67.09

0.33

66.58 66.59 59.76 60

66.93

-0.13 -0.13

66.44 40

66.45 66.45

-0.23

66.36 31.84

66.22

-0.13

66.27 20

66.23

65.88

CHAINAGE

15.07

66.31

EXISTING LEVELS

66.12 66.12 66.12 66.21

66.34

0.27 0.27 0.17

R = -111.5

0 0.03 0.05 3.17

66.39 66.39 66.38

DESIGN LEVELS

0.04

R = -500

0.45

HORIZONTAL GEOMETRY

CUT / FILL DEPTH

K = 29.61 L = 100

70.11

VERTICAL GEOMETRY

K = 25.48 L = 11.9

G = -0.15%

DATUM R.L 62


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex GAS

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

CREST RL 73.56 CH 523.68m VIP RL 73.73 CH 524.52m

SAG RL 73.13 CH 455.78m VIP RL 72.97 CH 457.17m

VIP RL 74.13 CH 344.28m

CREST RL 74.08 CH 335.44m

Ex D

Ex ELEC

Ex ELEC

Ex ELEC Ex ELEC

Ex DRAI

Ex DRAI Des DRAI

Ex DRAI

Ex SEWR

G = -1.03%

L = 121.07

K = 25.7 L = 60

L = 130.91

1.78

LIZ KERNOHAN DRIVE - MCA1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 2 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-132

B

Mar 06, 2024 - 9:19am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-13.dwg

72.83 71.05 600

1.98 72.88 70.90 595.28

2.15 73.07 70.91 580

2.49 73.31 70.81 560

2.46 73.37 70.91 554.52

2.39 73.43 71.05 548.73

0.80 72.70 540

73.50

73.56 520

0.00 0.00 -0.00 73.39 73.43 73.45 73.39 73.43 73.45 494.52 498.07 500

-0.00 73.31 73.31 487.17

-0.00 73.24 73.24 480

0.01 73.13 73.12 460

0.01 73.17 440

73.17

73.28 73.29 427.17

-0.01

0.00 -0.01 73.35 73.32 73.35 73.32 420 423.36

73.56 73.55 400

0.01

-0.01 73.77 73.77 380

-0.00 73.93 73.93 364.28

0.00 73.97 73.97 360

0.00 74.07 74.07 340

0.00 0.00 0.00 74.04 74.05 74.05 74.04 74.05 74.05 320 322.6 324.28

0.06 73.93

CHAINAGE

307.44

73.99

0.14 73.80

73.95

EXISTING LEVELS

300

-0.01

R = 40

R = 214

DESIGN LEVELS

G = -1.2%

L = 74.7

HORIZONTAL GEOMETRY

CUT / FILL DEPTH

K = 16.67 L = 40

K = 27.66 L = 60

73.55

L = 100

VERTICAL GEOMETRY

K = 27.88 L = 40

G = 0.4%

K = 29.61

G = 1.13%

DATUM R.L 66


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex D

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 76.43 CH 817.16m

VIP RL 75.35 CH 772.18m

VIP RL 74.45 CH 731.08m

VIP RL 73.90 CH 708.22m

VIP RL 73.62 CH 689.94m

VIP RL 73.31 CH 670.97m

VIP RL 72.64 CH 615.28m SAG RL 72.76 CH 615.28m

Ex GAS

110 LODGES DRAI

110 LODGES DRAI Ex DRAI 110 LODGES DRAI Ex DRAIEx DRAI

110 LODGES DRAI

K = 50.01 L = 10

K = 50.01 L = 10

G = 1.2%

K = 16.67 L = 15

G = 2.4%

VERTICAL GEOMETRY

G = 1.5%

K = 16.67 L = 40

G = 1.64%

DATUM R.L 69

G = 2.2%

L = 130.91

K = 20.24 L = 30

G = 2.4%

G = 3.88%

L = 191.34

K = 21.74 L = 40

L = 29.6

0.04

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-13.dwg

LIZ KERNOHAN DRIVE - MCA1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 3 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-133

B

Mar 06, 2024 - 9:19am

79.70 900

79.73

-0.01 -0.01 -0.01 78.88 78.88 78.90 880 880.03 880.41

78.87 78.87 78.88

-0.07 78.16 860

78.09

-0.12 77.84 850.43

77.72

-0.12 77.44 840

77.32

-0.19 77.21 832.16

77.01

-0.17 76.74 820

76.58

-0.18 -0.19 76.20 76.26 800 802.16

76.02 76.07

-0.11 -0.12 75.58 75.66 777.18 780

75.47 75.54

-0.07 75.31 767.18

75.24

-0.10 75.18 760

75.08

-0.01 74.65

74.64

-0.06 74.56

740

74.30 726.08

74.62

74.22 720

736.08

0.03

74.09 715.72

74.33

-0.04

73.72 73.74 700 700.72

74.18

-0.01

73.51 689.94

74.08

0.05 0.05

72.79 680

73.77 73.78

0.11

72.36 670.97

73.62

0.67

72.08 72.11 658.67 660

73.46

0.95

71.72 640

73.31

1.09 1.07

71.64 635.28

73.16 73.18

1.22

71.39

CHAINAGE

620

72.94

1.24

71.05

72.88

EXISTING LEVELS

600

72.83

DESIGN LEVELS

72.77

1.78

CUT / FILL DEPTH

1.38

HORIZONTAL GEOMETRY


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

VIP RL 79.66 CH 900.41m

VIP RL 84.21 CH 980.00m

VIP RL 92.44 CH 1132.51m

Ex D Ex GAS

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

Des DRAI

Des DRAI

Des DRAI

G = 5.4%

L = 1.88

-0.02 -0.01 -0.00

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-13.dwg

92.56 92.57 92.57 1160 1162.51 1164.87

LIZ KERNOHAN DRIVE - MCA1 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 4 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-134

B

Mar 06, 2024 - 9:19am

92.39 1146.14

1184.83

92.27 1140

1180

-0.04 91.68 1120

91.64

-0.14 -0.13 91.45 91.53 1112.23 1114.11

91.31 91.40

-0.11 -0.11 90.80 90.93 1100 1102.51

90.69 90.83

-0.18 90.39 1091.21

90.22

-0.12 89.74 1080

89.61

-0.15 88.68 1060

88.53

-0.16 87.61

86.56 1020

R = -94.5

1040

85.49 1000

87.45

-0.19

84.37 980

86.37

-0.20

83.23 960

85.29

-0.17

82.07 940

84.20

-0.16

80.96 80.98

CHAINAGE

920 920.41

83.07

79.70

81.93

EXISTING LEVELS

900

79.73

DESIGN LEVELS

80.78 80.81

0.04

CUT / FILL DEPTH

-0.14

R = 62

-0.18 -0.18

HORIZONTAL GEOMETRY

L = 38.69

92.55 92.56 92.57

L = 190.63

-0.00

L = 29.6

92.38

G = 5.72%

K = 11.96 L = 60

-0.01

VERTICAL GEOMETRY

K = 122.99 L = 40

92.26

K = 21.74 L = 40

G = 0.38%

DATUM R.L 77


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex GAS

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 73.56 CH 78.97m

VIP RL 72.93 CH 15.73m SAG RL 72.97 CH 18.47m

MCA1 (RL73.32) (CH0.00)

Ex D

Ex GAS Ex COMS Ex ELEC Des DRAI

Ex DRAI

Des DRAI

Des DRAI Des DRAI

K = 3.26 L = 12

VERTICAL GEOMETRY

G = 0.75%

G = -2.68%

DATUM R.L 67

G = 1%

L = 40.59

0.00

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-14.dwg

RHEINBERGERS CIRCUIT - MC01 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS RHEINBERGERS CIRCUIT - MC01 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-141

B

Mar 06, 2024 - 9:19am

73.64 90.08 90.2

73.64 73.64

-0.00 -0.00 -0.00 73.56 73.56 73.57 78.97 79 80

73.56 73.56 73.57

73.40 60

73.37

2.98 2.95 70.18 70.22 40 40.59

73.17 73.17

3.64 3.60 69.33 69.39 20 21.73

72.97 72.99

68.90 9.73

CHAINAGE

68.69

EXISTING LEVELS

-0.01 0

73.35 73.35

DESIGN LEVELS

73.09

4.66

CUT / FILL DEPTH

-0.03

R = 43

4.19

HORIZONTAL GEOMETRY


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

Ex GAS

EXISTING GAS

Ex COMS

EXISTING COMMS

Ex ELEC

EXISTING ELECTRICAL

Ex WATR

EXISTING ELECTRICAL

VIP RL 73.16 CH 30.29m

VIP RL 73.02 CH 16.54m SAG RL 73.05 CH 18.54m

Ex D

Des DRAI

Ex DRAI

K = 17.61 L = 18

G = 2.02%

VERTICAL GEOMETRY

L=8

G = -3%

K=2

G = 1%

DATUM R.L 70

L = 26.58

L = 12.33

-0.00 0.00 -0.00 -0.00

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-15.dwg

GRIMES AVENUE - MC02 A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD LONGITUDINAL SECTIONS GRIMES AVENUE - MC02 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-151

B

Mar 06, 2024 - 9:19am

74.21 57.75

73.34 73.35 73.37 73.37 73.34 73.35 73.37 73.37 73.52 39.29 40 41 41.07 45.42

73.05 73.06 73.07 73.13 73.67 73.67 73.68 73.62 20 20.54 21.29 26.58

0

CHAINAGE

12.54

72.96

EXISTING LEVELS

73.64

73.51

DESIGN LEVELS

73.14

0.55

CUT / FILL DEPTH

-0.61 -0.61 -0.61 -0.49

R = -35

-0.51

HORIZONTAL GEOMETRY


LEGEND DESIGN SURFACE EXISTING SURFACE LODGES DRIVE DESIGN PROPOSED STORMWATER MAIN

D

EXISTING STORMWATER MAIN

C

L = 8.19

L = 8.18

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-16.dwg

40

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PATH LONGITUDINAL SECTIONS PATH (MP11), (MP12) AND (MP31) Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-161

B

Mar 06, 2024 - 9:19am

A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

30

EXISTING ELECTRICAL

65.81 65.73

A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

20

Ex WATR

12.8 16.37

A1 Horizontal Scale 1 : 500 A1 Vertical scale 1 : 100

10

EXISTING ELECTRICAL

0.18 8.18

66.00 65.81

0 1.72

MP31

5

Ex ELEC

G = -1.31%

G = -5.15%

G = 0.86%

0.34 0.31 65.83 65.86

CHAINAGE

MP12

0

EXISTING COMMS

L = 1.72 R = 12.5R = -23.29

66.17 66.17

-0.10 -0.17 -0.23 66.29 66.23 66.17 66.40 66.40 66.40 57.8 60 62.21

66.43 66.43 53.04

0.09 0.08 66.81 66.72 66.72 66.64 40 43.12

0.04 67.41 67.37

-0.11

EXISTING LEVELS

67.64

DESIGN LEVELS

24.97

15.69

CUT / FILL DEPTH

67.75

67.93

CHAINAGE

HORIZONTAL GEOMETRY

20

-0.09

68.93 68.77

65.44 65.44

68.58 68.47

EXISTING LEVELS

0 2.38

65.34 65.35 26.47 27.44

DESIGN LEVELS

37.44 38.24

65.27 65.28 19.53 20

-0.35 -0.30

CUT / FILL DEPTH

VERTICAL GEOMETRY

MP11

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

Ex COMS

K = 1.36 K = 2.14

L = 4.41 R = -100

R = -30

67.84

HORIZONTAL GEOMETRY

0.16 0.13

65.21 65.27

CHAINAGE

9.53 12.81

65.50 65.48

0.36 0.34

64.97 65.06

65.63 65.62

0.43 0.40

EXISTING LEVELS

0 1.13

65.48 65.49

DESIGN LEVELS

65.64 65.67

0.51 0.43

CUT / FILL DEPTH

R = 30

L = 37.35

0.00

G = -4.7%

VERTICAL GEOMETRY

L = 2.38

R = -30

G = -2.89%

K = 10

L = 13.66 HORIZONTAL GEOMETRY

EXISTING GAS

DATUM R.L 63

L = 18.15

L = 10

K = 3.51

G = 0.97%

G = -1.87%

K = 2.77 L = 10

VERTICAL GEOMETRY

G = 1.74%

DATUM R.L 64

G = 1.22%

DATUM R.L 61

Ex GAS

VIP RL 65.78 CH 12.28m

CREST RL 66.18 CH 1.17m VIP RL 66.21 CH 4.09m

VIP RL 66.98 CH 34.04m

VIP RL 65.39 CH 32.44m SAG RL 65.42 CH 34.01m

VIP RL 65.49 CH 1.13m

VIP RL 65.72 CH 14.53m CREST RL 65.68 CH 14.35m

Ex D


19.00m CARRIAGEWAY

1.20m

1.20m

3.20m RIGHT TURN LANE

3.50m TRAFFIC LANE

3.50m TRAFFIC LANE

1.80m MEDIAN

3.50m TRAFFIC LANE

2.00m

3.50m TRAFFIC LANE

2.50m SHARED PATH

MIN 0.60m VARIES

DESIGN SURFACE

MCB1

1.10m

MIN 5.10m (VARIES)

BOUNDARY

BOUNDARY

3.50m

℄ 3.7%

2.0%

2.0%

-3.0%

2.8%

-3.0%

1 in -4

1 in -4 FP1

FP2 P5

M1 WHERE SHOWN IN PLAN

STW EXISTING SURFACE

TYPICAL SECTION - (MCB 1) - CAMDEN VALLEY WAY (APPROX. CH600) SCALE 1:50

14.00m CARRIAGEWAY

3.50m TRAFFIC LANE

3.50m TRAFFIC LANE

3.50m TRAFFIC LANE

2.00m

2.50m SHARED PATH

MIN 0.60m VARIES

MCB1

3.50m TRAFFIC LANE

MIN 5.10m (VARIES)

BOUNDARY

BOUNDARY

3.50m

℄ 2.0%

2.0%

-3.0%

-3.0%

1 in -4

1 in 4

1 in -4

P5

FP2

TYPICAL SECTION - (MCB1) - CAMDEN VALLEY WAY (APPROX. CH400)

EXISTING SURFACE

SCALE 1:50

14.00m CARRIAGEWAY 3.50m

3.50m TRAFFIC LANE

3.50m TRAFFIC LANE

3.50m

3.50m

TRAFFIC LANE DESIGN SURFACE

MCB1

3.50m TRAFFIC LANE

2.0%

-3.0%

-3.0%

1 in -4

1 in -4

P5

STW

TYPICAL SECTION - (MCB1) - CAMDEN VALLEY WAY (APPROX. CH160)

EXISTING SURFACE

STW

SCALE 1:50 SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

5 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TYPICAL ROAD CROSS SECTIONS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:50

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-201

B

Mar 06, 2024 - 9:19am

2.0%

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-20.dwg

℄


BOUNDARY

BOUNDARY

5.90m

13.00m NOM. CARRIAGEWAY 3.50m

3.50m

3.40m

VARIES

TRAFFIC LANE

TRAFFIC LANE

SHOULDER

2.90m

2.50m SHARED PATH

-2.0%

2.0%

0.50m

MC03

3.90m LEFT TURN LANE

℄ 2.0%

-3.0%

-3.0%

EXISTING SURFACE

TYPICAL SECTION - (MC03) - HILDER STREET (APPROX. CH40)

P3

FP2

DESIGN SURFACE

BOUNDARY

SCALE 1:50

3.50m TRAFFIC LANE

3.50m LEFT TURN LANE

3.20m RIGHT TURN LANE

1.80m PAINTED MEDIAN

3.50m TRAFFIC LANE

2.00m

-2.1%

-2.1%

1.00m

MCA2

3.50m

℄ 2.0%

3.1%

-3.0%

-3.0%

4.0%

-10.0%

1 in -4

1 in -4

DESIGN SURFACE

M1 WHERE SHOWN ON PLANS

P4

TYPICAL SECTION - (MCA2) - KIRKHAM LANE (APPROX. CH220)

EXISTING SURFACE

BOUNDARY

BOUNDARY

SCALE 1:50

12.00m NOM. CARRIAGEWAY 1.00m

2.00m

3.50m

3.50m

2.00m

1.00m

-3.0%

-10.0%

TRAFFIC LANE

MCA2

TRAFFIC LANE

1.80m PAINTED MEDIAN

-3.0%

-3.0%

1 in -4

1 in -4

P4 SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

5 metres

M1 WHERE SHOWN ON PLANS DESIGN SURFACE

TYPICAL SECTION - (MCA2) - KIRKHAM LANE (APPROX. CH120)

EXISTING SURFACE

SCALE 1:50 Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

NOT FOR CONSTRUCTION ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TYPICAL ROAD CROSS SECTIONS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:50

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-202

B

Mar 06, 2024 - 9:20am

-3.0%

-9.9%

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-20.dwg

℄


BOUNDARY

BOUNDARY

25.00m 4.50m

16.00m

4.50m

CARRIAGEWAY 1.10m

1.20m

2.50m

3.50m

4.00m

3.50m

2.50m

PARKING/TREE PIT

TRAFFIC LANE

MEDIAN

TRAFFIC LANE

PARKING/TREE PIT

2.20m

2.50m

0.60m 1.00m

SHARED PATH

MCA1

FOOTPATH

1.40m

REGRADE AREA

TIERED SANDSTONE BLOCK RETAINING WALL REFER RETAINING WALL PLANS AND DETAILS

℄ -3.5%

2.5%

-3.0%

2.5%

2.5%

-3.0%

FP2

FP1

-5.0%

DESIGN SURFACE

LANDSCAPED MEDIAN WHERE SHOWN ON PLANS P5

STW

-5.0%

EXISTING SURFACE

TYPICAL SECTION - (MCA1) - LIZ KERNOHAN DRIVE (APPROX. CH200)

BOUNDARY

BOUNDARY

SCALE 1:50

28.00m 19.00m CARRIAGEWAY

4.50m 1.20m

2.20m

2.50m

4.50m

FOOTPATH

1.80m MEDIAN

3.50m

3.50m

RIGHT TURN LANE

TRAFFIC LANE

TRAFFIC LANE

MCA1

TRAFFIC LANE

3.20m

DIVERSION CHANNEL 2

0.60m

SHARED PATH

-3.0%

2.5%

-3.0%

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-20.dwg

-4.5%

2.5%

1V:6H

2.50m

DESIGN SURFACE

℄ -0.7%

1.40m

1V:4H FP2

EXISTING SURFACE

P5 M1 WHERE SHOWN IN PLAN

FP1

SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

TYPICAL SECTION - (MCA1) - LIZ KERNOHAN DRIVE (APPROX. CH30)

5 metres

SCALE 1:50 Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

NOT FOR CONSTRUCTION ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TYPICAL ROAD CROSS SECTIONS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:50

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-203

B

Mar 06, 2024 - 9:20am

1.10m

4.50m


BOUNDARY

BOUNDARY

25.00m 4.50m

16.00m

4.50m

CARRIAGEWAY 1.10m

1.20m

2.20m

3.50m

4.00m

3.50m

2.50m

PARKING/TREE PIT

TRAFFIC LANE

MEDIAN

TRAFFIC LANE

PARKING/TREE PIT

MCA1

FOOTPATH

2.50m

1.40m

2.50m

0.60m

SHAREDPATH

DESIGN SURFACE

℄ 2.8%

2.5%

EXISTING SURFACE

-3.0%

1V:4H

2.5%

-3.0%

FP1

FP2 M1 WHERE SHOWN IN PLAN

P5

TYPICAL SECTION - (MCA1) - LIZ KERNAHAN DRIVE (APPROX. CH480)

BOUNDARY

BOUNDARY

SCALE 1:50

25.00m 4.50m

16.00m

EXISTING VERGE FORMATION

CARRIAGEWAY

4.50m

3.50m

1.00m

3.00m

3.50m

2.50m EXISTING

EXISTING PARKING

TRAFFIC LANE

MEDIAN

RIGHT TURN BAY

TRAFFIC LANE

PARKING/TREE PIT

MCA1

2.50m

℄

DESIGN SURFACE

VARIES

EXISTING SURFACE

M1 WHERE SHOWN IN PLAN

TYPICAL SECTION - (MCA1) - LIZ KERNOHAN DRIVE (APPROX. CH400) SCALE 1:50

SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

5 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TYPICAL ROAD CROSS SECTIONS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:50

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-204

B

Mar 06, 2024 - 9:20am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-20.dwg

P5


BOUNDARY

BOUNDARY

25.00m 4.50m

16.00m

4.50m

CARRIAGEWAY 0.60m

2.50m

1.40m

3.50m

1.00m

3.00m

3.50m

2.50m

SHOULDER

TRAFFIC LANE

MEDIAN

RIGHT TURN BAY

TRAFFIC LANE

SHOULDER

1.40m

2.50m

0.60m

FOOTPATH

DESIGN SURFACE

MCA1

FOOTPATH

2.50m

℄ 2.5%

-2.3%

-3.0%

1V:4H

2.5%

FP2 FP2

HERBERT RIVULET WORKS - NOT IN THIS CONTRACT

M1 WHERE SHOWN ON PLANS

P5

PROPOSED 4 x 2100W x 1500H RCBC

HERBERT RIVULET WORKS - NOT IN THIS CONTRACT

TYPICAL SECTION - (MCA1) - LIZ KERNOHAN DRIVE (APPROX. CH560)

0

0.5

1

2

3

4

5 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TYPICAL ROAD CROSS SECTIONS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:50

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-205

B

Mar 06, 2024 - 9:20am

SCALE 1:50 @ A1 SCALE 1:100 @ A3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-20.dwg

SCALE 1:50


BOUNDARY

13.50m 4.50m 0.60m

2.50m

1.40m

3.50m

SHOULDER

TRAFFIC LANE

MEDIAN

120-130 LODGES ROAD DEVELOPMENT (STAGE 2)

2.00m MEDIAN

MCA1

FOOTPATH

1.00m OFFSET TO

2.50m

℄ 2.5%

-3.0%

1V:4H

FP1

DESIGN SURFACE

LANDSCAPED MEDIAN WHERE SHOWN ON PLANS P5

EXISTING SURFACE

TYPICAL SECTION - (MCA1) - LIZ KERNOHAN DRIVE (APPROX. CH1000)

BOUNDARY

BOUNDARY

SCALE 1:50

14.50m

MCA1

LYNDSAY DYNAN - 110 LODGES ROAD DESIGN

1.00m OFFSET TO

2.00m

3.50m

2.50m

MEDIAN

TRAFFIC LANE

PARKING/TREE PIT

1.40m

2.50m

0.60m

SHAREDPATH

1.00mm OFFSET TO

℄

MEDIAN

MEDIAN

-2.5%

1V:4H

M1 WHERE SHOWN ON PLANS

EXISTING SURFACE

P5

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-20.dwg

FP2 DESIGN SURFACE

TYPICAL SECTION - (MCA1) - LIZ KERNOHAN DRIVE (APPROX. CH600) SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

SCALE 1:50

5 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TYPICAL ROAD CROSS SECTIONS SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:50

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-206

B

Mar 06, 2024 - 9:20am

-3.0%


BOUNDARY

BOUNDARY

16.00m 7.00m NOM.

4.50m

4.50m

CARRIAGEWAY 1.10m

1.20m

2.20m

3.50m

TRAFFIC LANE

TRAFFIC LANE

MC01

FOOTPATH

3.50m

REGRADE AREA

4.50m

DESIGN SURFACE REGRADE AREA

℄ 2.5%

2.5%

-3.0%

-3.0%

EX STW

FP1

P6

TYPICAL SECTION - (MC01) - RHEINBERGERS CIRCUIT (APPROX. CH40)

EXISTING SURFACE

BOUNDARY

BOUNDARY

SCALE 1:50

16.00m 4.50m VARIES 1.10m MIN

7.00m NOM.

4.50m

CARRIAGEWAY 1.20m

2.20m

3.50m

TRAFFIC LANE

TRAFFIC LANE

1.40m

2.50m

0.60m

SHAREDPATH

MC02

FOOTPATH

3.50m

EXISTING SURFACE

℄ 1V:4H

2.5%

-3.0%

2.5%

-3.0%

1V:4H

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-20.dwg

FP2

EX STW P6 DESIGN SURFACE

TYPICAL SECTION - (MC02) - GRIMES AVENUE (APPROX. CH20) SCALE 1:50

SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

5 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TYPICAL ROAD CROSS SECTIONS SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:50

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-207

B

Mar 06, 2024 - 9:20am

FP1


MCB1 MCB1

MCB1

2.0%

-3.0%

-3.0%

1 in -4

1 in -4

2.0%

-3.0%

-3.0%

-4.5%

-3.0%

-3.0%

1 in -4

Ex Sewr Ex Watr 500mm 450mm CICL DICL CL.64.37 CL.64.25

-4.0%

Ex WatrEx Sewr 450mm500mm CICL DICL CL.65.63CL.65.7

Ex Sewr Ex Watr 500mm 450mm CICL DICL CL.65.09 CL.64.94

Ex Watr 250mm DICL CL.65.64

.2 1 in

-3.8

1 in 4

Ex Watr 250mm DICL CL.64.17

630mm PE CL.63.2

Ex Watr 250mm DICL CL.65.05

DATUM R.L 58.00

0

1

2

4

6

8

-0.03 65.48 14.40

65.45

-0.13 65.12 12.52

64.98

0.09 65.85 65.76 9.20

0.41 65.78 7.73

66.20

0.45 66.26 65.81

0.00 65.46 10.88

65.46

0.57 65.78 7.35

66.35

0.54 66.41 65.88

DESIGN OFFSETS

5.09

0.00 66.03 66.03 9.06

0.23 66.64 66.41 6.59

0.21 66.73 66.52 3.77

0.24 66.84 66.60

EXISTING LEVELS

CH 40

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

DESIGN LEVELS

Ex Watr 250mm DICL CL.63.93

CH 80

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-301

B

Mar 06, 2024 - 9:20am

CH 10

0.00

0.26 66.75 66.49

66.27 66.26 66.25 -9.17 -7.81 -6.53

DESIGN OFFSETS

-3.21

66.27 66.61 66.65

66.90 66.81

EXISTING LEVELS

66.84 66.81

67.05 67.06

DESIGN LEVELS

6.31 6.66

0.00

3.31

67.15 67.13

67.05 -3.23

-7.05 -6.55

DESIGN OFFSETS

67.00

66.74 66.87 66.74 66.77

EXISTING LEVELS

0.00 0.35 0.39

LEVEL DIFFERENCE

0.06 0.00

LEVEL DIFFERENCE

-0.01

LEVEL DIFFERENCE

0.02

DATUM R.L 59.00

0.05

DATUM R.L 60.00

0.00 0.09

DATUM R.L 61.00

DESIGN LEVELS

1 in -4

Ex Sewr Ex500mm Watr 450mm CICLDICL CL.64.7 CL.64.59

Ex Watr 250mm DICL CL.65.31

0.00 0.88 0.88 0.79 0.78 0.62 0.64 0.58

Ex Sewr Ex Watr 500mm DICL 450mm CICL CL.65.55 CL.65.29

Ex Watr 250mm DICL CL.65.72

65.75 66.62 66.62 66.56 66.56 66.41 66.45 66.57

Ex WatrEx Sewr 450mm 500mm CICL DICL CL.65.81CL.65.87

-3.0%

65.75 65.75 65.74 65.77 65.78 65.78 65.81 65.99

-5.0%

-3.0%

1 in -4

-8.20 -8.20 -8.00 -4.68 -4.53 -4.50 -4.05 0.00

-3.0%

-3.0%

-5.5%

5.75

MCB1

MCB1

MCB1

2.0%

-3.0%

-3.0%

1 in -4

0.66 65.77 0.00

CH 100

CH 60

CH 20

66.43

65.52 65.53 65.54 65.56 -5.13 -4.98 -4.95 -4.50

DESIGN OFFSETS

0.88 0.87 0.72 0.74

66.47 65.44 -8.45

EXISTING LEVELS

66.41 66.41 66.26 66.30

64.64

DESIGN LEVELS

1.03

LEVEL DIFFERENCE

-15.77

0.00 65.88

65.88

0.43 66.50 66.06

9.45

4.43

-8.31 -8.31 -8.11 -4.79 -4.64 -4.61 -4.16 -3.26 0.00

6.32 6.82

DESIGN OFFSETS

6.97

65.98 65.98 65.98 66.08 66.09 66.09 66.11 66.17 66.29

66.68 66.67

EXISTING LEVELS

66.17

65.98 66.76 66.76 66.69 66.69 66.54 66.58 66.61 66.70

DESIGN LEVELS

66.57

0.00 0.78 0.78 0.61 0.60 0.45 0.47 0.44 0.41

0.12 0.00

LEVEL DIFFERENCE

66.79 66.67

0.02 3.32

66.89

66.91

0.06 67.01 66.95 0.00

-7.35 -6.55

DESIGN OFFSETS

-3.23

66.57 66.60

EXISTING LEVELS

66.82

66.57 66.77

DESIGN LEVELS

66.92

0.00 0.17

LEVEL DIFFERENCE

0.10

DATUM R.L 61.00

0.40

DATUM R.L 60.00


MCB1

MCB1 2.0%

2.0%

-3.0%

-3.0%

1 in -4

1 in -4

0.6%

1 in -4

CH 140

Ex Watr 250mm DICL CL.63.79

0

1

2

4

6

8

0.36 0.35 0.50 0.51 0.43 0.00 65.37 65.34 65.34 65.33 65.48 65.64 65.63 65.65 65.65 65.65 65.68 65.67 6.55 7.00 7.03 7.18 10.50 11.80

0.28 66.02 65.74 0.00

0.64 0.63 0.48 0.49 65.30 65.30 65.31 65.33 -7.18 -7.03 -7.00 -6.55

65.93 65.93 65.78 65.82

66.00 65.26 -10.50

6.55 7.00 7.03 7.18 10.50

DESIGN OFFSETS

CH 120

SCALE 1:100 @ A1 SCALE 1:200 @ A3

64.82

66.10 66.06 66.21 66.21 66.27

EXISTING LEVELS

65.77 65.75 65.74 65.71

66.29 65.57 0.00

-9.36

DESIGN OFFSETS

-6.04 -5.89 -5.86 -5.41

65.30 65.31 65.31 65.33

66.24 66.24 66.09 66.13

66.17

EXISTING LEVELS

DESIGN LEVELS

-15.22

LEVEL DIFFERENCE

0.33 0.31 0.46 0.50

LEVEL DIFFERENCE

0.72

DATUM R.L 59.00

0.94 0.93 0.78 0.80

DATUM R.L 59.00

0.74

450mm CICL500mm DICL CL.63.8 CL.63.79

Ex Watr 250mm DICL CL.64.62

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

Ex Watr Ex Sewr

1 in -4

0.19 0.14 0.29 0.28 0.31 0.00

D

D Ex Watr Ex Sewr 450mm CICL 500mm DICL CL.63.96 CL.63.96

2.0%

-3.0%

-3.0%

CH 160

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-302

B

Mar 06, 2024 - 9:20am

2.0%

65.82 65.78 65.93 65.93 66.00 65.67

2.0%

-3.0%

1 in -4

DESIGN LEVELS

6.55 7.00 7.03 7.18 10.50 11.58

0.00 MCB1

MCB1

CH 180

-3.0%

-2.0%

65.73 65.69 65.84 65.84 65.91 65.64

0.24 65.69

65.93

0.54 0.53 0.38 0.40 65.36 65.36 65.37 65.38 -7.33 -7.18 -7.15 -6.70

65.89 65.89 65.74 65.78

0.69 65.22 -10.66

DESIGN OFFSETS

0.00

65.37

EXISTING LEVELS

65.20

65.37

DESIGN LEVELS

65.20

0.00

LEVEL DIFFERENCE

13.57

0.15 0.12 0.27 0.27 0.80 65.96 65.92 66.07 66.07 66.14 6.55 7.00 7.03 7.18 10.50

65.81 65.80 65.80 65.80 65.34

66.16 65.71 0.00

66.08 66.08 65.93 65.97 65.17 65.17 65.18 65.20

65.12 -10.27

-6.95 -6.80 -6.77 -6.32

66.14

64.51 -16.80

0.45

LEVEL DIFFERENCE

0.91 0.90 0.75 0.76

DATUM R.L 59.00

1.03

DATUM R.L 58.00

DESIGN OFFSETS

Ex Watr 250mm DICL CL.64.76

Ex WatrEx Sewr 450mm CICL500mm DICL CL.63.86 CL.63.87

-13.54

630mm PE CL.63.04

Ex Watr 250mm DICL CL.63.79

65.91

Ex Watr Ex Sewr 450mm CICL 500mm DICL CL.63.72 CL.63.69

EXISTING LEVELS

1 in -4

D

D

DESIGN LEVELS

2.0%

-3.0%

-2.1%


2.3%

1 in -4.7

630mm PE CL.62.75

66.29 66.29 66.14 66.17 65.18 65.18 65.18 65.19 -18.27 -18.10 -18.07 -17.56

66.37

-28.98

DESIGN OFFSETS

65.08

64.89

EXISTING LEVELS

-22.07

64.89

DESIGN LEVELS

1.30

0.00

LEVEL DIFFERENCE

1.11 1.11 0.96 0.98

DATUM R.L 58.00

MCB1

MCB1

CH 220

2.2%

.3 1 in -4

-0.5%

-1.8%

-4.1%

2.0%

1 in -4

.2

2

4

6

8

1.16 1.03 65.44 65.44 15.33 15.49

66.60 66.47

1.41 65.44 13.61

66.85

1.56 65.32 0.00

66.87

1.24 1.37 1.37 1.59 65.26 65.26 65.29 65.30 -11.49 -11.33 -9.92 -9.61

66.50 66.63 66.66 66.89

1.41 1.41 1.26 1.29 65.00 65.00 65.00 65.01 -22.96 -22.81 -22.78 -22.32

66.41 66.41 66.26 66.30

1.55 66.48

0.00 64.86

64.92

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

1

-26.31

-1.39 -1.23 -1.15 0.00 0.60 0.68 0.83

8.94 9.40 9.44 9.59 13.06 14.31

DESIGN OFFSETS

CH 240

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-303

B

Mar 06, 2024 - 9:20am

0

Ex Watr 250mm DICL CL.64.55

64.86

65.39 65.37 65.37 65.36 65.67 65.70

EXISTING LEVELS

CH 200

SCALE 1:100 @ A1 SCALE 1:200 @ A3

-1.6%

-32.82

0.43 0.41 0.56 0.57 0.33 0.00

DESIGN LEVELS

65.82 65.78 65.93 65.93 66.00 65.71

0.64 0.77 0.77 0.76 0.65 0.61 0.48 65.50 65.50 65.50 65.52 65.63 65.67 65.67

66.14 66.27 66.27 66.28 66.28 66.28 66.15

0.92 0.92 0.77 0.79 66.09 66.09 65.94 65.98 65.18 65.18 65.18 65.19 -10.97 -10.81 -10.78 -10.31

66.17 -14.44

65.08 -19.13

65.30

65.08

0.87

LEVEL DIFFERENCE

0.00

LEVEL DIFFERENCE

DESIGN OFFSETS

-0.2%

630mm PE CL.62.65

DATUM R.L 58.00

EXISTING LEVELS

0.2%

Ex Watr Ex Sewr 450mm500mm CICL DICL CL.64.1 CL.64.09

DATUM R.L 58.00

DESIGN LEVELS

-1.9%

-1.8%

Ex Watr 250mm DICL CL.64.79

Ex Watr 450mm CICLEx Sewr CL.64.04500mm DICL CL.63.65

630mm PE CL.62.82

2.0%

1 in -4


MCB1

MCB1 2.2%

.1 1 in -4

2.2%

-2.8%

-2.4%

1 in -4

.1 Ex Coms

D

Ex Watr Ex Sewr 450mm CICL 500mm DICL CL.63.9 CL.63.73

2.0%

1 in -4

-3.0%

-3.0%

Ex Watr 250mm DICL CL.64.2

Ex Coms

Ex Sewr 500mm DICL CL.63.01

Ex Watr 450mm CICL CL.62.82

Ex Sewr 630mm PE CL.62.33

DATUM R.L 57.00

0.0%

-2.4%

2.0%

D

1 in -5.1

0.7%

1.6%

Ex Watr 450mm CICL CL.63.42

D Ex Sewr 500mm DICL CL.63.44

8

-0.00 0.02 0.02 65.36 65.37 65.37 18.71 18.81 19.33 21.88 22.49 22.73

65.36 65.39 65.39 65.42 65.43 65.47

0.00 65.08 13.54

65.08

0.47 0.46 0.61 0.62 0.92 65.19 65.16 65.16 65.15 64.92 6.55 7.00 7.03 7.18 10.50

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

6

CH 300

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-304

B

Mar 06, 2024 - 9:20am

CH 260

4

Ex Watr 250mm DICL CL.64.08

65.66 65.62 65.77 65.77 65.84

0.70 65.16 0.00

65.86

0.59 0.60 0.45 0.51 65.18 65.17 65.17 65.15 -7.18 -7.03 -7.00 -6.55

65.77 65.77 65.62 65.66

0.95 65.84

0.00 64.80

64.89

DESIGN OFFSETS

-10.50

EXISTING LEVELS

64.80

DESIGN LEVELS

-14.67

0.05 0.05 0.00 65.79 65.81 65.76 65.75 65.76 65.76 31.56 32.18 32.45

0.00 0.05 65.69 65.75 65.69 65.69 28.23 28.47

0.00 65.65 65.65 22.77

0.98 0.97 1.12 1.14 0.52 65.09 65.06 65.06 65.04 65.75

66.07 66.03 66.18 66.18 66.26

1.10 1.10 0.98 66.46 66.46 66.33 65.35 65.35 65.35

14.93 15.46 15.49 15.67 19.65

-2.58 -2.42 -2.33 0.00

4.19 4.27 4.43

1.18 1.30 1.29 1.18 66.32 66.46 66.46 66.46 65.15 65.16 65.17 65.28

66.27 66.27 66.12 66.16 -14.56 -14.40 -14.36 -13.88

65.21 65.22 65.22 65.23

66.35 -18.15

64.95 -24.39

65.12

64.95

1.23

1.05 1.05 0.90 0.92

LEVEL DIFFERENCE

0.00

LEVEL DIFFERENCE

2

1.1%

5.6%

630mm PE CL.62.41

DATUM R.L 57.00

1

1 in -4

Ex Coms

DATUM R.L 57.00

DESIGN OFFSETS

2.0%

-3.0%

-3.0%

Ex Coms

630mm PE CL.62.57

EXISTING LEVELS

2.0%

1 in -4

Ex Watr 250mm DICL CL.64.16

Ex Sewr 450mm500mm CICL DICL CL.64.09 CL.63.98

DESIGN LEVELS

0.34 0.33 0.48 0.48 0.67 0.53 0.51 0.40 0.41 0.00

MCB1

-0.0%

-1.5%

65.08 65.05 65.05 65.04 64.90 65.07 65.10 65.26 65.27 65.28

CH 320

MCB1 2.3%

6.55 7.00 7.03 7.18 9.48 10.47 11.00 13.68 14.33 16.07

0.00

CH 280

1 in -4.5

65.42 65.38 65.53 65.53 65.57 65.60 65.61 65.66 65.68 65.28

0.49 65.12

65.61

0.43 0.45 0.30 0.36 65.10 65.08 65.08 65.06 -7.18 -7.03 -7.00 -6.55

65.53 65.53 65.38 65.42

0.81 64.78 -10.50

65.59

0.00

0.00 65.23 65.23 14.85

64.57

0.49 0.61 0.76 0.77 1.00 65.89 65.86 66.01 66.01 66.08 65.40 65.24 65.24 65.24 65.08

64.57

0.87 66.10 65.23 0.00

-14.58

0.83 0.82 0.66 0.65 66.02 66.02 65.87 65.90 65.18 65.20 65.20 65.25

-12.13

DESIGN OFFSETS

7.34 7.79 7.82 7.98 11.35

1.05 66.09 65.04

EXISTING LEVELS

-8.75 -8.60 -8.57 -8.11

0.00

DESIGN OFFSETS

64.91

EXISTING LEVELS

DESIGN LEVELS

64.90

DESIGN LEVELS

LEVEL DIFFERENCE

-17.00

DATUM R.L 57.00

LEVEL DIFFERENCE

0

.4

Ex Watr 250mm CICL CL.64.14

D

630mm PE CL.62.49

SCALE 1:100 @ A1 SCALE 1:200 @ A3

1 in -4

2.0%

2.0%


MCB1

MCB1

1 in -4

2.0%

1 in -4

1 in 4

-3.0%

-3.0%

2.0%

375mm DICL CL.64.54 Ex Sewr 630mm PE CL.62.62

2.0%

1 in -4

-3.0%

-3.0%

2.0%

Ex Sewr 630mm PE CL.62.55

2

4

6

8

-0.36 -0.37 0.00 64.95 64.95 65.37 65.31 65.32 65.37 19.22 19.72 21.39 21.86

65.37 65.38 19.26 19.76

65.41

-0.48 -0.49

65.06 65.24 15.37 16.37

64.89 64.89

0.53 0.37

0.54 0.52 0.67 0.67 0.76 1.31 64.77 64.76 64.76 64.75 64.70 64.20 6.55 7.00 7.03 7.18 9.00 11.50

65.32 65.28 65.43 65.43 65.46 65.51

0.56 64.95 0.00

0.57 0.58 0.43 0.50 65.43 65.43 65.28 65.32 64.85 64.84 64.84 64.82 -7.18 -7.03 -7.00 -6.55

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

1

CH 380

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-305

B

Mar 06, 2024 - 9:20am

0

65.49

14.37

DESIGN OFFSETS

CH 340

SCALE 1:100 @ A1 SCALE 1:200 @ A3

-10.50

65.18 65.14 65.29 65.29 65.33 65.38

65.43

EXISTING LEVELS

65.05 65.04 65.04 65.04 65.18 6.55 7.00 7.03 7.18 9.00 11.50

65.38 0.00

-7.18 -7.03 -7.00 -6.55

-10.50

DESIGN OFFSETS

65.10

65.29 65.29 65.14 65.18

1.39 65.36 63.96

EXISTING LEVELS

DESIGN LEVELS

64.45

LEVEL DIFFERENCE

375mm DICL CL.64.52

450mm CICL CL.61.89

-14.68

LEVEL DIFFERENCE

0.13 0.10 0.25 0.25 0.15

DATUM R.L 57.00

0.28

DATUM R.L 57.00

DESIGN LEVELS

1 in 4

Ex Watr 250mm CICL CL.63.61

Ex Watr Ex Sewr 500mm DICL CL.63.15

65.51

Ex Watr 250mm CICL CL.63.37

Ex Sewr 500mm DICL CL.63.05

1 in -4 ExComs Coms Ex

Ex Coms

Ex Watr 450mm CICL CL.62.03

0.65 0.59 65.12 65.21 14.83 15.83

MCB1

MCB1

2.0%

-3.0%

-3.0%

65.52 65.48 65.63 65.63 65.66 65.71

CH 400

CH 360

2.0%

64.73 64.67 64.67 64.66 64.41 64.67

64.94 0.00

21.89

DESIGN OFFSETS

0.83 0.82 0.67 0.70 64.80 64.80 64.80 64.81 -7.18 -7.03 -7.00 -6.55

EXISTING LEVELS

65.63 65.63 65.48 65.52

65.69 64.48 -10.50

1.21 64.35

65.44

-15.87

-0.48 -0.48 64.83 64.83

DESIGN LEVELS

65.30 65.31 18.93 19.43

0.12 0.08 65.32 65.33 15.92 16.92

65.20 65.25

65.13 65.09 65.24 65.24 65.26 65.28 6.55 7.00 7.03 7.18 9.00 11.50

64.96 64.91 64.90 64.86 64.82 64.88

65.33 0.00

-7.18 -7.03 -7.00 -6.55

-13.69

DESIGN OFFSETS

-10.50

65.01 65.03 65.03 65.03

EXISTING LEVELS

65.02

65.24 65.24 65.09 65.13

65.26

64.46

DESIGN LEVELS

0.17 0.18 0.35 0.38 0.44 0.40

LEVEL DIFFERENCE

0.31

LEVEL DIFFERENCE

0.24 0.22 0.06 0.11

DATUM R.L 57.00

0.79 0.80 0.96 0.96 1.25 1.05

450mm CICL CL.61.87

450mm CICL CL.61.9

DATUM R.L 57.00

375mm DICL CL.64.5

Ex Watr 250mm CICL CL.63.66

Ex Sewr 500mm DICL CL.63.24

6.55 7.00 7.03 7.18 9.00 11.50

Ex Sewr 500mm DICL CL.63.08

Ex Watr

0.77

Ex Watr 250mm CICL CL.63.75

65.71

Ex Watr

1 in 4

Ex Coms

Ex Coms

Ex Sewr 630mm PE CL.62.48

1 in -4

65.78 65.80

0.9%

-3.0%

-3.0%

65.59 65.61

0.6%

1 in -4


MCB1

MCB1

2.0%

-3.0%

-3.0%

2.0%

1 in -4

Ex Sewr 500mm DICL CL.63.34

2.0%

-3.0%

-3.0%

1 in -4

2.0%

-3.0%

-3.0%

2.0%

Ex Watr Ex Sewr 500mm DICL CL.63.26

6

8

-0.16 -0.16 0.00 -0.15 -0.16 0.00 65.10 65.10 65.27 65.26 65.26 65.27 19.51 20.01 20.69

1.06 1.06 66.21 66.23 65.15 65.17 14.00 15.00

1.26 1.25 1.40 1.41 1.61 1.20 65.97 65.93 66.08 66.08 66.11 66.16 64.71 64.68 64.68 64.67 64.50 64.97 6.55 7.00 7.03 7.18 9.00 11.50

1.20 66.06 64.86 3.50

1.31 66.16 64.85 0.00

1.34 1.35 1.20 1.22 1.28 66.08 66.08 65.93 65.97 66.06 64.73 64.73 64.73 64.75 64.78 -7.18 -7.03 -7.00 -6.55 -3.50

1.56 66.14 64.58

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

4

-10.50

19.18 19.68 20.88

DESIGN OFFSETS

CH 460

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-306

B

Mar 06, 2024 - 9:20am

2

64.45

65.02 65.02 65.32

EXISTING LEVELS

CH 420

1

-17.29

0.80 0.79 65.97 65.99

DESIGN LEVELS

65.17 65.20 14.28 15.28

6.55 7.00 7.03 7.18 9.00 11.50

64.68 64.62 64.61 64.59 64.33 64.87

65.72 65.68 65.83 65.83 65.86 65.91

1.04 1.06 1.21 1.23 1.53 1.05

0.98 65.91 64.94

64.84 64.83 64.83 64.81 -7.18 -7.03 -7.00 -6.55

-10.50

-16.17

0.00

65.83 65.83 65.68 65.72

64.47

65.89

0.98 1.00 0.85 0.91

LEVEL DIFFERENCE

0

375mm DICL CL.64.44

450mm CICL CL.61.82

LEVEL DIFFERENCE

SCALE 1:100 @ A1 SCALE 1:200 @ A3

Ex Sewr 500mm DICL CL.63.3

Ex Sewr 630mm PE CL.62.84

DATUM R.L 57.00

DESIGN OFFSETS

Ex Watr 250mm CICL CL.63.86

Ex Watr

450mm CICL CL.61.85

EXISTING LEVELS

65.20 65.20 65.21 Ex Coms

375mm DICL CL.64.48

Ex Watr 250mm CICL CL.63.64

DATUM R.L 57.00

DESIGN LEVELS

19.25 19.75 20.42 1 in -4

1 in -4

1 in 4

Ex Coms

Ex Sewr 630mm PE CL.62.69

65.04 65.04 65.21

0.98 0.98 66.04 66.06 65.06 65.09 14.17 15.17

1.08 1.06 1.21 1.22 1.38 1.13 65.80 65.76 65.91 65.91 65.94 65.99 64.71 64.69 64.69 64.69 64.56 64.86 6.72 7.17 7.20 7.35 9.17 11.67

1.06 65.89

MCB1

MCB1 2.0%

64.83

CH 480

CH 440

1 in -4

3.67

64.82 64.83 0.00 0.17

19.41 19.91 20.91

1.20 1.20 1.05 1.08 1.13 64.70 64.70 64.70 64.71 64.75 -7.18 -7.03 -7.00 -6.55 -3.50

65.17 65.19

DESIGN OFFSETS

65.90 65.90 65.75 65.79 65.88

65.97 64.46 -10.50

1.51 64.43

65.08 65.08 65.33

-16.64

0.99 0.99 66.16 66.18

DESIGN LEVELS EXISTING LEVELS

14.00 15.00

1.24 1.24 1.39 1.41 1.65 1.18 65.92 65.88 66.03 66.03 66.06 66.11 64.67 64.63 64.63 64.62 64.41 64.93 6.55 7.00 7.03 7.18 9.00 11.50

1.11 66.01

66.11 64.90

64.89 3.50

-7.18 -7.03 -7.00 -6.55 -3.50

0.00

66.03 66.03 65.88 65.92 66.01

64.62 -10.50

64.83 64.83 64.83 64.81 64.83

66.09

64.51 -16.81

1.21

LEVEL DIFFERENCE

1.20 1.20 1.05 1.10 1.18

LEVEL DIFFERENCE

1.47

DATUM R.L 57.00

DESIGN OFFSETS

375mm DICL CL.64.42

450mm CICL CL.61.8

DATUM R.L 57.00

EXISTING LEVELS

Ex Coms

Ex Sewr 630mm PE CL.62.93

450mm CICL CL.61.84

DESIGN LEVELS

1 in -4

Ex Watr 250mm CICL CL.63.79

1.16 1.16

Ex Sewr 630mm PE CL.62.77

375mm DICL CL.64.46

Ex Watr 250mm CICL CL.63.82

Ex Sewr 500mm DICL CL.63.28

2.0%

Ex Watr

Ex Coms Ex Watr

-3.0%

-3.0%

1 in -4

65.99 65.99

2.0%

1 in -4


-3.0%

MCB1

MCB1 2.0%

1 in -4

3.0%

2.0%

-3.0%

Ex Watr

1 in -4

1 in 4

-1.5%

1 in -4

Ex Coms

Ex Watr

Ex Watr 250mm CICL CL.63.77

Ex Sewr 500mm DICL CL.63.35

Ex Sewr 630mm PE CL.63.25

375mm DICL CL.64.38 630mm PE CL.63.49

1 in 4

Ex Coms 375mm DICL CL.64.34

450mm CICL CL.61.74

DATUM R.L 57.00

CH 520

1 in -4

1 in 4

2.0%

1 in -4 375mm DICL CL.64.4

Ex Sewr 630mm PE CL.63.41

450mm CICL CL.61.79

6

8

0.41 0.29 0.44 0.41 0.47 0.41 0.39 0.37 -0.34 -0.35 0.00 64.78 64.85 64.86 64.89 64.87 64.98 65.00 65.05 65.14 65.15 65.18 10.95 11.40 11.43 11.58 13.40 15.90 16.50 17.50 19.95 20.45 21.94

65.19 65.15 65.30 65.30 65.33 65.38 65.39 65.41 64.80 64.80 65.18

0.59 64.68 7.90

65.28

0.47

0.54 0.45 0.60 0.58 0.48 0.50 0.50 0.49 64.75 64.80 64.80 64.82 64.96 64.99 65.00 65.03 9.86 10.31 10.34 10.49 12.31 14.81 15.41 16.41 19.03 19.53 20.82

65.29 65.25 65.40 65.40 65.44 65.49 65.50 65.52 64.86 64.86 65.19

0.60 64.78 6.81

65.38

0.59 65.49 64.89 3.31

0.54 65.39 64.85 0.00

0.59 0.59 0.44 0.48 0.53 64.71 64.71 64.71 64.71 64.75 -7.18 -7.03 -7.00 -6.55 -3.50

0.92 65.37 64.44 -10.50

19.04 19.54 20.60

DESIGN OFFSETS

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

4

375mm DICL CL.64.36

CH 540

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-307

B

Mar 06, 2024 - 9:20am

2

1 in 4

Ex Coms

64.36

64.98 64.98 65.25

EXISTING LEVELS

CH 500

1

1 in -4

Ex Watr 250mm CICL CL.63.72

-14.52

0.90 0.88 1.03 1.03 1.06 0.83 0.81 0.80 65.62 65.58 65.73 65.73 65.77 65.82 65.86 65.88

DESIGN LEVELS

64.72 64.70 64.70 64.70 64.71 64.98 65.05 65.08 7.54 7.99 8.02 8.17 9.99 12.49 14.47 15.47

65.71 64.82 4.49

65.79 65.82 64.83 64.86 0.00 0.99

64.71 64.71 64.71 64.71 64.74 -7.18 -7.03 -7.00 -6.55 -3.50

-10.50

64.45

65.70 65.70 65.55 65.59 65.68

1.32 65.77

64.42 -15.90

DESIGN OFFSETS

0.89

LEVEL DIFFERENCE

0.96 0.96

LEVEL DIFFERENCE

0.99 0.99 0.84 0.88 0.94

DATUM R.L 57.00

EXISTING LEVELS

2.0%

450mm CICL CL.61.75

DATUM R.L 57.00

DESIGN LEVELS

-3.0%

Ex Sewr 500mm DICL CL.63.35

65.30 65.30 65.15 65.19 65.28

Ex Sewr 630mm PE CL.63.09

Ex Watr 250mm CICL CL.63.91

Ex Sewr 500mm DICL CL.63.35

3.0%

-3.0% Ex Watr

Ex Coms Ex Watr

64.91

MCB1 2.0%

-3.0%

-3.0%

4.40

CH 560

MCB1 2.0%

1 in -4

65.38

0.36 64.90 0.00

65.25

65.11 65.13 65.15 65.16 65.16 65.01 65.05 65.15 64.43 64.55 64.69 64.72 64.72 64.72 64.73 64.80 -10.50 -9.40 -8.20 -7.18 -7.03 -7.00 -6.55 -3.50

0.69 0.58 0.46 0.44 0.44 0.29 0.33 0.35 64.24

DESIGN OFFSETS

18.76 19.26 20.41

EXISTING LEVELS -13.99

64.92 64.92 65.21

0.69 0.71 0.86 0.86 0.70 0.67 0.67 0.67 65.45 65.41 65.56 65.56 65.60 65.65 65.67 65.69

DESIGN LEVELS

64.76 64.71 64.70 64.71 64.90 64.98 65.00 65.02

5.65

LEVEL DIFFERENCE

8.70 9.15 9.18 9.33 11.15 13.65 14.68 15.68

0.74 64.81

65.55

0.75 65.65 64.90 2.15

0.75 65.59 64.84 0.00

65.50 65.50 65.35 65.39 65.48 -7.18 -7.03 -7.00 -6.55 -3.50

-15.98

DESIGN OFFSETS

-10.50

64.35

EXISTING LEVELS

64.69 64.69 64.69 64.69 64.74

64.20

DESIGN LEVELS

65.57

1.21

0.81 0.81 0.66 0.70 0.74

DATUM R.L 57.00

LEVEL DIFFERENCE

0

1 in -4

Ex Watr 250mm CICL CL.63.88

Ex Sewr 500mm DICL CL.63.35

450mm CICL CL.61.77

SCALE 1:100 @ A1 SCALE 1:200 @ A3

2.0%

-3.0%

3.0%

-3.0%


MCB1

MCB1 2.0%

1 in -4

3.0%

3.1%

-3.0%

2.0%

-3.0%

1.4% D

Ex Watr 250mm CICL CL.63.91

Ex Sewr 500mm DICL Ex Watr CL.63.4

-0.1%

-0.4%

Ex Coms Ex Watr D

Ex Sewr 500mm DICL 450mm CICLCL.63.99 CL.63.49

450mm CICL CL.61.7

DATUM R.L 57.00

CH 600

0.33 0.00

65.92

66.24

1.83 64.39 -24.98

66.22

2.17 64.02 -31.72

66.19

2.52 66.21

DESIGN OFFSETS

63.69

EXISTING LEVELS

-33.44

0.43 0.46 0.57 0.57 0.63 0.64 0.54 0.51 0.51 0.69 0.67 0.82 0.81 0.49 0.40 0.40 65.74 65.77 65.87 65.87 65.91 65.91 65.81 65.78 65.68 65.59 65.55 65.70 65.70 65.73 65.78 65.80

DESIGN LEVELS

65.31 65.31 65.31 65.30 65.28 65.28 65.28 65.28 65.17 64.90 64.88 64.88 64.88 65.25 65.39 65.40

65.64 65.24

LEVEL DIFFERENCE

3.20 3.21 3.36 3.44 4.76 4.84 4.99 5.00 8.50 11.55 12.00 12.03 12.18 14.00 16.50 17.10

2.0%

2.0% 1 in -4

1 in 4

2.0%

375mm DICL CL.64.32

0

1

2

4

6

8

2.0%

65.66 65.66 65.66 65.66 65.64 65.65 65.65 65.65 65.56 65.46 65.40 65.38 65.33 64.71 65.15 65.26

66.04 66.07 66.17 66.17 66.16 66.16 66.06 66.03 65.93 65.84 65.80 65.95 65.95 65.98 66.03 66.05

0.38 0.41 0.51 0.51 0.52 0.52 0.41 0.38 0.37 0.38 0.40 0.56 0.61 1.28 0.88 0.79

Ex Coms

3.20 3.21 3.36 3.43 4.77 4.84 4.99 5.00 8.50 11.55 12.00 12.03 12.18 14.00 16.50 17.10

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

CH 580

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0.35 65.60

DESIGN OFFSETS

0.00

65.48 65.51 65.61 65.61 65.63 65.63 65.53 65.50 65.50 65.40 65.31 65.27 65.42 65.42 65.45 65.50 65.52 65.54 64.74 64.74 65.27 65.05 65.05 65.05 65.05 65.03 65.03 65.03 65.03 65.03 64.75 64.74 64.87 64.88 64.92 65.14 65.17 65.18 65.19 65.24 65.25

EXISTING LEVELS

3.94 3.95 4.10 4.17 4.71 4.79 4.94 4.95 4.95 8.45 11.50 11.95 11.98 12.13 13.95 16.45 17.05 18.05 21.22 21.72 23.84

65.35 65.02

64.48 64.58 64.70 64.70 64.69 64.69 64.67 64.86 -10.50 -9.40 -8.20 -7.18 -7.03 -7.00 -6.55 -3.50

0.00

65.33 65.31 65.29 65.27 65.27 65.12 65.16 65.25

64.28 -14.74

DESIGN LEVELS

1.46 1.33 1.23 1.19 1.19 1.04 1.07 0.73

LEVEL DIFFERENCE

0.43 0.46 0.57 0.57 0.60 0.60 0.50 0.48 0.47 0.65 0.56 0.40 0.54 0.49 0.31 0.33 0.34 0.35 -0.50 -0.50

LEVEL DIFFERENCE

0.34

DATUM R.L 58.00

0.86 0.73 0.59 0.57 0.58 0.43 0.48 0.39

DATUM R.L 57.00

DESIGN OFFSETS

-3.0%

Ex Watr 250mm CICL CL.63.92

Ex Sewr 500mm DICL CL.63.62 Ex Watr 450mm CICL CL.62.47

65.92 65.90 65.88 65.86 65.86 65.71 65.75 65.84

Ex Sewr 500mm DICL CL.63.35

450mm CICL CL.61.72

EXISTING LEVELS

-0.5%

CH 620

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-308

B

Mar 06, 2024 - 9:20am

Ex Watr 250mm CICL CL.63.84

64.46 64.57 64.65 64.67 64.67 64.67 64.68 65.11

Ex Watr

DESIGN LEVELS

3.0%

-3.0%

Ex Coms

D 630mm PE CL.63.48

2.0%

-3.0%

3.3%

-3.0%

-10.50 -9.40 -8.20 -7.18 -7.03 -7.00 -6.55 -3.50

1 in -4

MCB1

MCB1

CH 640

65.94

-15.88

DESIGN OFFSETS

-10.50 -9.40 -8.20 -7.18 -7.03 -7.00 -6.55 -3.50

64.50 64.63 64.75 64.66 64.64 64.63 64.55 65.02

EXISTING LEVELS

0.00

64.28

DESIGN LEVELS

65.62 65.60 65.58 65.56 65.56 65.41 65.45 65.54

1.12 0.98 0.83 0.89 0.92 0.78 0.90 0.52

LEVEL DIFFERENCE

0.40

DATUM R.L 59.00


MCB1 2.0%

-3.0%

-4.0%

-3.2%

2.0%

-3.0%

-1.9%

-2.0%

1 in -6

1 in -4 D

D

Ex Watr Ex Sewr 450mm CICL 500mm DICL CL.65.53 CL.65.29

1 in 6

Ex Coms 375mm DICL CL.65.93

Ex Watr 250mm CICL CL.65.1

0.09 0.05 -0.01 -0.30 -0.30 -0.30 -0.02 0.02 66.83 66.78 66.72 66.42 66.41 66.42 66.72 66.76 66.74 66.74 66.73 66.71 66.71 66.72 66.74 66.74 20.05 20.55 21.34 23.13 23.63 24.13 25.93 26.20

0.28 66.60 17.55

66.88

-0.11 -0.13 0.03 0.03 0.25 66.86 66.83 66.83 66.82 66.67 11.55 12.00 12.03 12.18 15.50

66.75 66.71 66.86 66.86 66.92

-0.02 0.01 0.11 0.10 -0.03 -0.03 -0.14 -0.26 -0.25 67.09 67.13 67.23 67.23 67.18 67.18 67.08 66.94 66.84 67.11 67.11 67.12 67.13 67.20 67.21 67.21 67.20 67.09 0.00 0.00 0.15 0.23 1.57 1.65 1.80 5.00 8.50

67.01 67.01 66.86 66.90 66.99 66.05 66.08 66.09 66.17 66.74 -7.18 -7.03 -7.00 -6.55 -3.50

67.07 65.26 -10.50

DESIGN OFFSETS

64.89

EXISTING LEVELS

-19.22

64.89

DESIGN LEVELS

1.81

0.00

LEVEL DIFFERENCE

0.96 0.93 0.77 0.72 0.25

DATUM R.L 60.00

-1.0%

-0.7%

0.3%

-2.5%

-2.7%

1.8%-6.2%

0.2%

MCB1

MCB1

CH 680

-8.2%

Ex Watr 375mm DICL CL.65.52

2.0%

-3.0%

0

1

2

4

6

8

2.0%

-3.0%

2.6%

-2.0%

1 in -6

-0.10 -0.13 -0.11 -0.35 -0.33 -0.31 0.11 -0.00

67.62

67.77 67.75 67.72 67.65 67.64 67.62 67.50 67.39

17.56

20.06 20.56 21.38 23.18 23.68 24.18 25.98 27.33

67.67 67.62 67.61 67.31 67.30 67.31 67.61 67.38

0.10

67.62 67.60 67.60 67.59 67.51 11.55 12.00 12.03 12.18 15.50

67.72

-0.13 -0.15 0.00 0.01 0.16

67.90 67.90 67.91 67.91 67.99 67.99 68.00 67.95 67.86 0.00 0.00 0.15 0.23 1.57 1.65 1.80 5.00 8.50

67.49 67.45 67.60 67.60 67.67

-0.07 0.04 0.14 0.13 0.01 0.00 -0.11 -0.27 -0.28

1.04 1.01 0.85 0.79 0.19 66.71 66.74 66.75 66.85 67.54 -7.18 -7.03 -7.00 -6.55 -3.50

67.75 67.75 67.60 67.64 67.73

1.59 67.82

65.85

375mm DICL CL.66.35

66.22

DESIGN OFFSETS

Ex Coms

-10.50

EXISTING LEVELS

1 in 6 1 in -6

65.85

DESIGN LEVELS

Ex Watr D 250mm CICL CL.66.55

Ex Watr Ex Sewr 450mm CICL 500mm DICL CL.66.56 CL.66.41

CH 660

SCALE 1:100 @ A1 SCALE 1:200 @ A3

-5.5%

-18.35

0.03 -0.15 -0.24 66.34 66.25 66.20 66.31 66.40 66.44 19.10 20.27 20.77

66.23 66.19 66.34 66.33 66.17 66.16 66.16 66.15

0.00

13.80 14.34 14.38 14.56

66.36

66.57

1.40 1.30 1.16 1.13 66.26 66.17 66.14 66.21 -16.94 -16.29 -14.80 -13.77

64.86 64.87 64.98 65.07

65.98 66.13 66.14 -29.74 -29.50 -28.26

-33.47

DESIGN OFFSETS

64.75 64.77 64.82

65.99 64.66

EXISTING LEVELS

0.06 0.03 0.18 0.18

LEVEL DIFFERENCE

0.21

LEVEL DIFFERENCE

1.23 1.37 1.33

DATUM R.L 61.00

1.33

DATUM R.L 56.00

0.00

D

DESIGN LEVELS

-4.0%

1 in -4

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

Ex Watr 250mm CICL CL.64.45

67.84 67.95 68.05 68.05 67.99 67.99 67.89 67.69 67.58

Ex Sewr 450mm CICL 500mm DICL CL.64.52 CL.64.51

CH 700

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-309

B

Mar 06, 2024 - 9:21am

Ex D Coms

D


MCB1

MCB1

1 in 2.0%

-3.1%

-3.0%

1 in -4

-3.4%

2.0%

1 in -4

2.0%

-3.0%

-3.0%

-3.0%

2

2.0%

Ex Watr D D

Ex Watr 450mm CICL Ex Sewr CL.68.45 500mm DICL CL.68.02

Ex Watr 250mm CICL CL.68.42

D 500mm PE CL.68.26

Ex WatrD 250mm CICL CL.70.21

450mm CICLEx Sewr CL.70.73 500mm DICL CL.69.96

500mm PE CL.69.77

19.05

74.18

74.18

0.00

-0.20 -0.54 -0.41 -0.51 -2.00 71.82 72.13 72.15 72.25 73.80 10.34 10.79 10.82 10.97 14.29

71.63 71.59 71.74 71.74 71.80

0.36 71.35 7.29

71.72

0.32 71.82 71.50 3.79

MCB1

MCB1 -3.0%

0.40 71.54 0.00

CH 780

CH 740

2.0%

71.94

-0.03 -0.06 -0.21 -0.24 0.33 71.88 71.91 71.91 71.98 71.50 -7.18 -7.03 -7.00 -6.55 -3.50

71.85 71.85 71.70 71.74 71.83

0.53 71.92 71.39

70.74

-10.50

DESIGN OFFSETS

70.74

EXISTING LEVELS

-15.22

69.51 69.47 69.62 69.62 69.69 69.91

DESIGN LEVELS

69.42 69.43 69.43 69.43 69.83 69.91

69.62 69.62 69.62 69.62 69.67 69.67 69.67 69.65 69.49

69.86 69.89 69.99 69.99 69.95 69.95 69.85 69.71 69.61

0.25 0.28 0.37 0.37 0.28 0.28 0.18 0.06 0.11

0.09 0.05 0.20 0.20 -0.13 0.00

LEVEL DIFFERENCE

11.55 12.00 12.03 12.18 15.50 16.38

-7.18 -7.03 -7.00 -6.55 -3.50

0.00 0.00 0.15 0.23 1.57 1.65 1.80 5.00 8.50

0.64 0.62 0.47 0.47 0.33 69.77 69.77 69.62 69.66 69.76 69.13 69.15 69.15 69.19 69.43

69.84

-17.17

DESIGN OFFSETS

-10.50

68.16

EXISTING LEVELS

68.77

68.17

DESIGN LEVELS

1.07

0.01

LEVEL DIFFERENCE

0.00

DATUM R.L 65.00

DATUM R.L 63.00

-3.9%

-3.0%

1 in -4

4.4%

2.0%

2.0%

1 in -4

-3.0%

-3.0%

2.0%

1 in

2.6

Ex Watr

0

1

2

4

6

8

0.00

0.37 0.40 0.50 0.49 0.47 0.46 0.36 0.33 0.26 0.36 -0.00 -0.24 -0.10 -0.17 -1.18

71.08 71.02 71.01 70.83 70.49

70.55 70.55 70.56 70.56 70.57 70.57 70.58 70.58 70.51 70.31 70.58 70.78 70.79 70.86 71.94

72.07

-7.18 -7.03 -7.00 -6.55 -3.50

0.00 0.00 0.15 0.23 0.40 0.48 0.63 0.63 4.81 8.31 11.36 11.81 11.84 11.99 15.31

18.74

70.92 70.95 71.05 71.05 71.03 71.03 70.93 70.90 70.78 70.67 70.58 70.54 70.69 70.69 70.76

-0.25 -0.19 -0.33 -0.11 0.32

0.17 70.73

70.90

0.00 70.22

-10.50

DESIGN OFFSETS

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

EXISTING LEVELS

CH 760

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 10 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-310

B

Mar 06, 2024 - 9:21am

CH 720

DESIGN LEVELS

500mm PE CL.69.01

70.22

-0.01 69.52

11.55 12.00 12.03 12.18 15.50 15.74

37.52

69.53

68.45 68.41 68.56 68.56 68.63 68.57 68.47 68.49 68.49 68.49 68.55 68.57

68.80 68.83 68.93 68.93 68.88 68.88 68.78 68.65 68.55 68.74 68.74 68.75 68.75 68.82 68.81 68.80 68.77 68.66 0.00 0.00 0.15 0.23 1.57 1.65 1.80 5.00 8.50

68.71 68.71 68.56 68.60 68.70 68.22 68.24 68.24 68.29 68.57

67.82 -10.50

-17.74

DESIGN OFFSETS

-7.18 -7.03 -7.00 -6.55 -3.50

68.78

66.97

EXISTING LEVELS

-0.01 -0.07 0.08 0.07 0.08 0.00

LEVEL DIFFERENCE

0.06 0.09 0.18 0.18 0.06 0.06 -0.03 -0.12 -0.11

LEVEL DIFFERENCE

0.50 0.48 0.33 0.32 0.12

DATUM R.L 64.00

0.97

DATUM R.L 62.00

DESIGN LEVELS

Ex Watr D 250mm CICL CL.69.36

450mm CICL Ex Sewr CL.69.59500mm DICL CL.68.94

72.07

D

Ex Watr D 250mm CICL CL.67.4

70.83 70.83 70.68 70.72 70.82

Ex Watr Ex Sewr 450mm CICL 500mm DICL CL.67.54 CL.67.5

-13.23

D


MCB1

MCB1

1 in

-3.3% 0.1%

-3.0%

-3.0%

2

Ex Watr

2

Ex Coms Ex ExWatr Watr Ex Sewr Ex Sewr 450mm CICL CL.74.94 500mm DICL CL.74.43

Ex Watr D250mm CICL CL.73.16

450mm Ex CICL Sewr CL.73.03 500mm DICL CL.72.22

2.0%

-3.0%

-3.0%

1 in -4

2.0%

1 in

Ex Watr 250mm CICL CL.75.24

D

500mm PE CL.72.8

500mm PE CL.71.28

DATUM R.L 68.00

0.00 77.36 77.36 14.11

-0.30 -0.32 -0.17 -0.16 -1.17 75.39 75.35 75.50 75.50 75.57 75.69 75.67 75.67 75.66 76.73 6.58 7.03 7.06 7.21 10.53

MCB1

MCB1

1 in 2.0%

-0.29

CH 860

CH 820

1 in -4

75.48 75.77 3.53

-0.16 -0.16 75.59 75.59 75.74 75.74 0.00 0.03

-0.10 75.48 75.58 -3.50

0.07 75.41 75.34

0.00 0.15 0.18 74.99 75.25 75.35

-5.78

DESIGN OFFSETS

74.99 75.10 75.17

78.22

EXISTING LEVELS

-9.87 -8.81 -7.81

78.22

DESIGN LEVELS

21.11

8.17 8.62 8.65 8.80 12.12

5.12

LEVEL DIFFERENCE

0.00

0.04 -0.16 -0.02 -0.10 -2.12 73.50 73.66 73.67 73.75 75.84

73.54 73.50 73.65 73.65 73.72

0.02 73.61

73.63

0.06 73.74 73.67 1.62

0.15 73.79 73.64 0.00

-0.57 -0.60 -0.76 -0.80

0.20 73.68

73.66

73.66 73.66 73.51 73.55 74.23 74.26 74.26 74.34

73.48 -3.50

-12.09

DESIGN OFFSETS

-8.59 -8.44 -8.41 -7.96

73.61

EXISTING LEVELS

73.89

73.61

DESIGN LEVELS

-10.50

0.00

LEVEL DIFFERENCE

-0.23

DATUM R.L 66.00

-3.0%

-3.0%

2

1 in

2.0%

2.0%

-3.0%

-3.0%

-9.3%

Ex Coms

2

Ex Watr Ex ExWatr Watr Ex Sewr 450mm Ex SewrCICL CL.74.02 500mm DICL CL.73.3

Ex Watr D CICL 250mm CL.71.69 500mm PE CL.70.53

0

1

2

4

6

8

0.00 78.91 78.91 19.59

-0.09 -0.10 0.06 0.07 -1.29 74.47 74.43 74.58 74.58 74.65 74.56 74.53 74.53 74.52 75.94 7.11 7.56 7.59 7.74 11.06

-0.15 74.56 74.72

74.73 74.74 0.00 0.56

4.06

-0.05 -0.07

74.55

74.69 74.67

0.03

-0.71 74.49

0.00 -0.09 -0.25

-3.50

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

Ex Watr 250mm CICL CL.74.13

CH 840

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 11 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-311

B

Mar 06, 2024 - 9:21am

CH 800

75.20

20.41

DESIGN OFFSETS

-6.50

76.39

EXISTING LEVELS

74.31 74.33 74.43

76.39

DESIGN LEVELS

74.31 74.43 74.68

0.00

-0.50 -0.77 -0.63 -0.71 -2.36 72.61 72.57 72.72 72.72 72.78 73.10 73.34 73.35 73.43 75.14 9.26 9.71 9.74 9.89 13.21

0.21 72.70 72.49 6.21

0.22 72.80 72.58 2.71

72.88 72.57 0.00

72.80 72.80 72.65 72.69 72.78

72.86 72.60

73.30 73.33 73.34 73.43 72.49 -7.18 -7.03 -7.00 -6.55 -3.50

-12.93

DESIGN OFFSETS

-10.50

72.26 72.26

EXISTING LEVELS

0.31

LEVEL DIFFERENCE

-0.50 -0.53 -0.69 -0.74 0.29

LEVEL DIFFERENCE

0.27

DATUM R.L 67.00

0.00

DATUM R.L 65.00

DESIGN LEVELS

D

500mm PE CL.72.04

74.58

450mm CICL CL.71.88 Ex Sewr 500mm DICL CL.70.99

-10.27 -9.54 -8.50

D


MCB1

MCB1

Ex Sewr Ex ExWatr Sewr Ex Watr 500mm DICL 450mm CICL CL.78.26 CL.78.05

1.4%

0

1

2

4

6

8

0.08

78.72 78.71 78.69 78.70 78.72 5.30 5.75 6.20 6.50 6.56

78.84 -0.00 78.26

78.15 78.13 78.10 78.08 78.06

3.50

5.50 5.95 6.40 6.70 7.13

78.25

-0.09 78.51

78.47

0.00

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-30.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

CH 920

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS CAMDEN VALLEY WAY - MCB1 SHEET 12 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-312

B

Mar 06, 2024 - 9:21am

CH 880

Ex Watr 250mm CICL CL.77.37

78.57

0.07 -0.07 78.34 78.58 -7.50 -6.50

78.41 78.51

0.00 77.36

DESIGN OFFSETS

77.36

76.64 76.62 76.61 76.56 76.75

EXISTING LEVELS

-11.71

-0.33 -0.36 -0.30 -0.23 0.00 76.31 76.27 76.31 76.33 76.75

DESIGN LEVELS

7.03 7.48 7.93 9.09 9.94

76.41 76.37

0.00

3.50 4.91

76.73 76.70

76.52 76.72

76.38 76.41 76.51 76.58 -4.57 -3.50

76.03 76.20 76.30 76.03 76.10 76.22 -8.88 -8.18 -7.18

-0.31 -0.33

LEVEL DIFFERENCE

-0.20

LEVEL DIFFERENCE

-0.13 -0.17

DATUM R.L 72.00

0.00 0.10 0.09

DATUM R.L 71.00

-0.10

Sewr Ex Watr Ex Ex Sewr Ex Watr 500mm 450mm DICL CICL CL.77.59 CL.77.45

Ex Watr 250mm CICL CL.75.77

-3.50

Ex Watr ExExSewr Ex Watr Sewr 450mm CICL 500mm DICL CL.75.87 CL.75.63

0.01 -0.01 0.06 0.08 0.00

2.0%

-4.8%

78.16 78.12 78.16 78.17 78.06

1 in -4

Ex Coms

DESIGN OFFSETS

78.76

MCB1

MCB1 -3.0%

-3.0%

EXISTING LEVELS

-0.01

CH 940

CH 900

DESIGN LEVELS

3.30

-6.97 -6.44 -5.44 -3.42

DESIGN OFFSETS

79.03

79.27 79.13 79.23 79.16 79.27 79.25 79.22 79.19

77.53 77.51 77.49 77.47 77.46

EXISTING LEVELS

Ex Watr 250mm CICL CL.78.07

79.04

-0.21 -0.23 -0.17 -0.14 0.00 77.32 77.28 77.32 77.33 77.46

DESIGN LEVELS

5.50 5.95 6.40 6.70 6.96

-0.20 77.40 3.50

0.00

77.60

77.53 77.71

77.49

77.36 77.46 77.16 77.31

77.64 -3.50

-9.67

DESIGN OFFSETS

-7.50 -6.50

76.82 76.82

EXISTING LEVELS

-0.18

LEVEL DIFFERENCE

-0.15

LEVEL DIFFERENCE

0.20 0.15

DATUM R.L 73.00

0.00

DATUM R.L 72.00

0.00 -0.12 0.01 -0.03

Ex Watr 250mm CICL CL.76.6

0.00

Ex Watr Ex Sewr Sewr Ex Ex Watr 500mm 450mm DICL CICL CL.76.74 CL.76.73

0.01 -0.02 0.04 0.03 0.00

Ex Coms

DESIGN LEVELS

-5.7%

78.42

1 in -4

3.8%

-3.8%

78.72 78.68 78.72 78.73 78.72

-10.0% -1.0%


Issue

-1 0

SCALE 1:100 @ A1 SCALE 1:200 @ A3

1cm at full size

0 1 2 4 6

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm

8

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

20cm

PHONE : (02) 4654 7777

DESIGN OFFSETS

CH 0

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

DESIGN OFFSETS

CH 30

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

0.59 0.74 0.74 0.75 0.76 0.75 0.60 0.66 0.53 0.65 0.61 0.19 0.19 0.35 0.30 -0.00

2.2%

Ex Coms Ex Watr

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

-2.8% -2.3%

SP

2.1%

1 in -4

CH 60

10 metres

NOT FOR CONSTRUCTION

Drawing Title

ROAD CROSS SECTIONS HILDER STREET - MC03 SHEET 1 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

A1

NSW210622

Q.A. Check

C106-340

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-34.dwg

66.32 66.47 66.47 66.47 66.51 66.51 66.36 66.20 66.16 66.31 66.31 66.25 66.25 66.30 66.26 65.96

-3.4%

65.72 65.72 65.72 65.73 65.76 65.76 65.76 65.54 65.63 65.66 65.70 66.06 66.06 65.95 65.95 65.96

1.3%

0.37 0.37 0.22 0.27

-8.0%

66.17 66.17 66.02 66.06

2.0%

0.35

-3.1%

66.22

MC03

CH 40

-0.51 -0.48 -0.32 0.00 1.76 1.91 1.94 7.61 8.07 8.10 8.26 10.94 10.97 13.52 14.04 15.27

65.80 65.80 65.80 65.79

EXISTING LEVELS

-8.66 -8.51 -8.48 -8.02

DESIGN LEVELS

65.87

LEVEL DIFFERENCE

-12.50

Ex Watr Ex Coms

1.7%

-0.00

-3.1%

65.86

66.30 66.26 66.41 66.41 66.40 66.45 66.40 66.22

66.47

0.32 0.32 0.44 0.32 0.05 0.12 0.08

0.33

1 in 8.1 -0.3%

65.86

65.98 65.94 65.97 66.09 66.35 66.33 66.32

66.14

-3.0%

MC03

6.14 6.59 6.63 6.78 9.50 12.01 12.51 13.13

0.00

65.76 65.72 65.75 65.87 66.16 66.14 66.14 66.13

65.94

66.25 66.21 66.36 66.36 66.29 66.33 66.28 66.13

66.40

66.26 66.26 66.11 66.15

0.48 0.48 0.61 0.49 0.13 0.19 0.15 -0.00

0.47

0.37 0.38 0.23 0.38

0.00 0.29

-2.6%

-16.99

-3.6%

5.53 5.98 6.01 6.16 8.86 11.36 11.86 12.59

0.00

-3.5%

0.23 0.22 0.35 0.21 0.00 0.06 0.04 0.00

MC03

65.89 65.89 65.89 65.77

-7.55 -7.40 -7.37 -6.92

66.04 66.33

0.11 0.11 0.24 0.11 0.00

0.15

7.0%

66.36 66.32 66.47 66.47 66.51 66.56 66.51 66.47

LEVEL DIFFERENCE 0.26

0.29 0.40 0.27 0.28

66.42 66.38 66.53 66.53 66.72

66.60

0.10 0.15 0.03 0.11

-2.5%

66.13 66.10 66.12 66.26 66.51 66.51 66.48 66.47

66.53

CH 10

66.27

2.0%

-3.6%

5.49 5.94 5.97 6.12 8.81 11.31 11.81 11.98

EXISTING LEVELS 66.33 66.33 66.18 66.22

CH 20

0.00

DESIGN LEVELS 66.04 65.93 65.91 65.94

DESIGN OFFSETS -7.53 -7.38 -7.35 -6.90

EXISTING LEVELS

0.21 0.33 0.19 0.19

DESIGN LEVELS

66.40 66.40 66.25 66.29

LEVEL DIFFERENCE

66.19 66.08 66.06 66.10

2.0%

-7.40 -7.25 -7.22 -6.77

LEVEL DIFFERENCE -0.00 0.09

66.31 66.27 66.29 66.43 66.72

66.44

66.04 66.04

DESIGN OFFSETS -12.02 -10.87

5.51 5.96 5.99 6.14 8.73

0.00

EXISTING LEVELS

-0.00 0.21

DATUM R.L 64.00

66.21 66.40

MC03

DESIGN LEVELS

66.21 66.19

0.04 0.04 0.16 0.04 0.00

0.05

66.47 66.47 66.32 66.36

-0.00 -0.03

LEVEL DIFFERENCE

-11.60 -10.85

66.49 66.45 66.60 66.60 66.91

66.66 -3.1%

66.38 66.47

66.46 66.42 66.44 66.56 66.91

66.62

66.37 66.32 66.30 66.25

66.58 66.54

Ex Watr Ex Coms

66.39 66.38

5.52 5.97 6.00 6.15 8.63

0.00

-7.21 -7.06 -7.03 -6.58

66.58 66.57

-3.1%

-11.05 -10.72

DATUM R.L 63.00

0.02

-1.7%

66.60

MC03

-3.6%

66.58

DATUM R.L 63.00

-0.00

0.01 0.05 -0.08 0.03

-10.69 -10.53

-3.6%

5.53

66.77

2.0%

66.77

66.54 66.54 66.39 66.43

0.00 -0.09 2.0%

0.00

66.53 66.49 66.47 66.40

DESIGN LEVELS 66.72 66.61

LEVEL DIFFERENCE

-7.02 -6.87 -6.84 -6.39

EXISTING LEVELS 66.72 66.70

DESIGN OFFSETS

0.01 0.12

DESIGN OFFSETS -10.79 -10.34

EXISTING LEVELS

66.66 66.66

DATUM R.L 64.00

0.00 -0.12

DESIGN LEVELS

66.65 66.53

DESIGN LEVELS 66.88 66.72

LEVEL DIFFERENCE

-6.82 -6.67

EXISTING LEVELS 66.88 66.85 2.0% 2.0%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:21am

DESIGN OFFSETS -10.75 -10.14

1 in -4

1.9%

Ex Coms Ex Watr

DATUM R.L 63.00

DATUM R.L 64.00

CH 50

2.0%

Ex Watr Ex Coms Ex Coms Ex Watr

DATUM R.L 63.00

.2

Ex Watr Ex Coms

MC03

MC03


MC03 0.5%

-1.1%

-0.5%

-2.0%

1.13 1.00 65.42 65.41 8.64 8.87

66.54 66.41

1.39 65.43 5.62

66.83

1.43 66.86 65.43 0.00

MCB1 MC03

CH 90

1.3%

1 in -4.8

-2.9%

-2.9%

2.9%

-3.0%

1.7%

-2.0%

-8.5%

1.31 1.18 65.30 65.30

66.61 66.48

1.57 66.87

1.55 66.88

1.15 1.28 1.31 1.54

CH 102.828 MC03

MCB1

MC03

CH 80

-2.1%

13.70 13.86

DESIGN OFFSETS

15.87 16.39 16.42 16.60

DESIGN OFFSETS

65.32

EXISTING LEVELS

65.45 65.46 65.47 65.47

EXISTING LEVELS

0.00

DESIGN LEVELS

66.13 66.09 66.24 66.24

DESIGN LEVELS

66.50 66.63 66.66 66.89

LEVEL DIFFERENCE

65.35 65.35 65.35 65.35

LEVEL DIFFERENCE

-13.86 -13.71 -12.34 -12.04

DATUM R.L 63.00

0.68 0.62 0.77 0.76

DATUM R.L 62.00

-0.1%

65.30

0.1%

-2.0%

12.03

65.40 65.40 -6.24 -5.62

DESIGN OFFSETS

65.40 65.40

EXISTING LEVELS

-8.87 -8.64

66.50 66.63

DESIGN LEVELS

66.66 66.89

1.10 1.23

LEVEL DIFFERENCE

1.26 1.49

DATUM R.L 63.00

0.2%

-0.2%

-1.9%

0

1

2

4

6

8

1.16 1.03 66.58 66.45 65.43 65.42 13.83 13.98

1.25 66.84 65.59 12.17

1.29 66.86

66.50 66.63 66.66 66.89

65.57

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-34.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

CH 100

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS HILDER STREET - MC03 SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-341

B

Mar 06, 2024 - 9:21am

CH 70

0.00

DESIGN OFFSETS

65.43 65.43 65.43 65.43

65.82

EXISTING LEVELS

-13.98 -13.83 -12.47 -12.17

0.31 66.13

DESIGN LEVELS

17.59

0.57 0.47 0.61 0.59 0.49 65.59 65.66 65.66 65.68 65.85

66.16 66.12 66.27 66.27 66.33

0.93 0.81 0.63 66.54 66.54 66.39 65.61 65.73 65.76

10.92 11.40 11.44 11.60 15.20

-2.06 -2.03 -1.88 0.00

3.14 3.29 3.32

66.24 66.39 66.39 66.44 65.51 65.51 65.51 65.56

66.07 66.07 65.92 65.97 65.74 65.74 65.74 65.75

66.12

-12.10 -11.93 -11.90 -11.38

-17.99

DESIGN OFFSETS

65.71

65.70

EXISTING LEVELS

-15.99

65.70

DESIGN LEVELS

0.73 0.88 0.88 0.88

LEVEL DIFFERENCE

0.34 0.34 0.18 0.22

LEVEL DIFFERENCE

0.41

DATUM R.L 63.00

0.00

DATUM R.L 63.00

1.07 1.20 1.22 1.45

Ex Watr Ex Coms


-3.0%

-3.0%

MCA2

MCA2

MCA2

1 -2.0%

.0% in -4-10

1 in -4

-3.0%

-3.0%

-2.0%-10.0%1 in

1 in -4

-4

-10.0%

-3.0%

3.0%

-3.0%

-2.0%-10.0% 1

in -4

Ex Watr Ex Watr

-3.0%

-3.0%

-2.0%-10.0%1 in

-10.0% 1 in -4

-4

0

1

2

4

6

0.00 63.44 12.16

63.44

1.24 0.80 62.94 63.28 8.58 9.58

64.18 64.08

62.69 6.58

63.99 3.08

64.22

1.53

0.34

0.18 64.23 64.05

64.33

-2.0%-10.0%1 in

-4

0.00 63.35 63.35 10.28

1.23 0.84 63.91 63.81 62.69 62.97 7.41 8.41

0.74 63.95 63.21 5.41

0.16 64.06 63.90 1.91

0.06 64.00 63.94 0.00

0.06 63.83 -3.50

63.90

0.23 0.10

0.00 63.28

63.50 63.74

DESIGN OFFSETS

-6.50 -5.50

EXISTING LEVELS

63.28

DESIGN LEVELS

-8.34

0.00 62.95 62.95 8.63

0.42 0.80 63.63 63.53 63.22 62.73 5.30 6.30

63.67 63.66 3.30

63.77 63.77 63.72 63.72

CH 40

8

-3.0%

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-35.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

3.0%

CH 80

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS KIRKHAM LANE - MCA2 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-351

B

Mar 06, 2024 - 9:21am

CH 0

0.00 0.10

63.67 63.63 -3.20

63.53 63.61 63.37 63.56 -6.20 -5.20

63.05 -8.11

DESIGN OFFSETS

-0.03 0.00

DESIGN OFFSETS

63.05

63.57 63.56 63.57 63.57

EXISTING LEVELS

0.02

LEVEL DIFFERENCE

0.05 0.05

LEVEL DIFFERENCE

0.04

LEVEL DIFFERENCE

0.16 0.05

DATUM R.L 58.00

0.00

DATUM R.L 58.00

0.00 -0.01

DATUM R.L 59.00

DESIGN LEVELS

-3.0%

Ex Watr

Ex Watr

63.74 63.84

.2%

0.00 MCA2

MCA2

MCA2

-8 1 in -4

EXISTING LEVELS

0.19 63.94 -3.50

CH 100

CH 60

CH 20

DESIGN LEVELS

64.13

0.28 0.21 63.97 64.07

63.33

63.69 63.86

DESIGN OFFSETS

-6.50 -5.50

EXISTING LEVELS

63.33

9.22

DESIGN LEVELS

-9.07

0.00 63.16

63.16

1.01 1.04 63.75 63.65 62.73 62.61 6.26 7.26

0.12 4.26

63.67

63.79

0.04 0.08 63.87 63.89 63.83 63.81 0.00 0.76

0.04 63.76 63.73 -3.50

63.60 63.70 63.51 63.64

63.17 63.17 -8.23

8.28

-6.50 -5.50

0.00 62.76

EXISTING LEVELS

0.09 0.06

LEVEL DIFFERENCE

0.00

LEVEL DIFFERENCE DESIGN LEVELS

62.76

0.10 0.37 63.54 63.46

63.57

0.02 63.66

63.57

63.44 63.09 4.70 5.50

-5.57 -5.50 -4.70 -3.10

DESIGN OFFSETS

DATUM R.L 58.00

DESIGN OFFSETS 3.10

63.47 63.47 63.49 63.53

EXISTING LEVELS

63.64

63.47 63.48 63.52 63.57

DESIGN LEVELS

0.00

0.00 0.02 0.03 0.04

LEVEL DIFFERENCE

-0.00

DATUM R.L 58.00

DATUM R.L 58.00

0.00

Ex Watr


MCA2

MCA2 -10.0%

1 in -4

-3.0%

3.0%

-3.0%

-2.0%-10.0%

1 in -4

1 in -4

Ex Watr

-3.0%

3.0%

-3.0%

-10.0%

-2.0%-10.0%

1 in -4

Ex Watr Ex Watr

DATUM R.L 58.00

CH 140

-10.0%

0.00 63.62 18.04

63.62

1.51 1.43 65.36 65.26 63.85 63.82 10.50 11.50

2.20 65.40 8.50

63.20

65.50 64.20

MCA2 -3.0%

3.0%

-3.0%

5.00

CH 180

MCA2 1 in -4

1.31

0.93 64.42

64.23 -3.50

0.00

63.94 -6.42

65.35

1.02

63.81 63.85 -9.42 -8.42

65.25

1.22

63.53 -15.30

65.16

1.19 1.25

DESIGN OFFSETS

65.00 65.10

63.31

EXISTING LEVELS

0.00

63.31

DESIGN LEVELS

63.53

0.00

LEVEL DIFFERENCE

16.96

1.30 1.21 10.41 11.41

63.50 63.49

64.80 64.70

1.74 64.84 63.09 8.41

4.91

63.92

64.94

1.02

0.59 64.79

0.72 64.69 63.97

64.21 0.00

-6.50 -5.50

-10.51

DESIGN OFFSETS

-3.50

63.53

EXISTING LEVELS

63.74 63.82

63.53

DESIGN LEVELS

64.53 64.63

0.00

LEVEL DIFFERENCE

0.79 0.81

DATUM R.L 59.00

-2.0%-10.0%

1 in -4

1 in -6.6

-3.0%

-3.0%

3.0%

-3.0%

-2.0%

Ex Sewr Ex Watr

1

2

4

6

8

1.69 63.39 10.50

65.08

1.78 63.34 8.50

65.12

1.26 63.96 5.00

65.22

0.76 65.07 64.32 0.00

0.79 0.79 64.18 64.18

64.97 64.97

0.74 64.91

-3.62 -3.50

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-35.dwg

0

CH 160

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS KIRKHAM LANE - MCA2 SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-352

B

Mar 06, 2024 - 9:21am

SCALE 1:100 @ A1 SCALE 1:200 @ A3

64.17

64.34

CH 120

-5.62

14.40

DESIGN OFFSETS

64.04

63.48

EXISTING LEVELS

-10.46

0.00

DESIGN LEVELS

63.48

1.19 0.95 64.50 64.40 63.30 63.45 9.74 10.74

1.68 64.54 62.86 7.74

0.63 64.64 64.01 4.24

64.51 64.13 0.00

64.41 64.02 -3.50

64.25 64.35

-9.57

DESIGN OFFSETS

-6.50 -5.50

63.48

EXISTING LEVELS

63.68 63.94

63.48

DESIGN LEVELS

0.39

LEVEL DIFFERENCE

0.39

LEVEL DIFFERENCE

0.57 0.41

DATUM R.L 59.00

0.00

DATUM R.L 58.00

0.30

Ex Watr Ex Watr


MCA2

MCA2

2.9%

2.0%

3.5%

3.1%

-3.0%

-2.0%

3.0%

-2.3%

3.9%

-4.3%

1.9%

-10.0%

1 in -4

1 in -3 .9

1 in -4 D

Ex Watr Ex Watr

0.00 63.75

MCA2

MCA2 1 in -4

-3.0%

4.0%

-3.0%

63.75

CH 260

CH 220

-0.9%

26.25

65.22 65.22 65.22 65.22 65.18 65.17 65.16 65.16 64.38 64.33 64.33 64.31 64.14 3.18 3.18 3.33 3.41 4.77 4.85 5.00 5.00 12.28 12.73 12.76 12.91 16.23

66.39 66.42 66.52 66.52 66.58 66.58 66.48 66.45 66.13 66.09 66.24 66.24 66.31

0.97 65.32 0.00

66.30

1.41 1.18 1.18 66.26 66.09 66.13

1.55

64.85 64.91 64.94

19.68

DESIGN OFFSETS

-8.61 -7.81 -7.33

63.81

EXISTING LEVELS

64.80

66.35

DESIGN LEVELS

-11.64

0.00

LEVEL DIFFERENCE

63.81

1.43 1.46 1.56 1.56 1.68 1.69 1.60 1.57 1.92 1.87 3.19 3.19 3.34 3.42 4.77 4.85 5.00 5.00 10.53 11.53

64.59 64.59 64.58 64.58 64.51 64.50 64.49 64.49 64.03 63.97

66.01 66.04 66.14 66.14 66.19 66.19 66.09 66.06 65.95 65.85

1.27 65.91 64.64 0.00

1.68 1.67 1.51 1.51 1.33 65.83 65.83 65.68 65.72 65.81 64.15 64.16 64.16 64.21 64.48 -7.18 -7.03 -7.00 -6.55 -3.50

65.89

-17.28

DESIGN OFFSETS

-10.50

64.20

EXISTING LEVELS

64.15

64.20

DESIGN LEVELS

1.75

0.00

LEVEL DIFFERENCE

1.17 1.20 1.31 1.31 1.40 1.41 1.32 1.29 1.75 1.76 1.91 1.93 2.16

DATUM R.L 59.00

DATUM R.L 59.00

2.0%

-2.0%-10.0%

1 in -4

1 in -4

3.0%

-3.0%

3.9%

-1.2%

-10.0% 1 in -4

0

1

2

4

6

8

0.00 63.94 63.94 21.12

1.46 1.49 1.59 1.60 1.73 1.74 1.65 1.62 2.32 2.09 66.25 66.28 66.38 66.38 66.44 66.44 66.34 66.31 66.23 66.13 64.79 64.79 64.79 64.79 64.71 64.70 64.69 64.69 63.91 64.04 3.19 3.19 3.34 3.41 4.77 4.85 5.00 5.00 11.34 12.34

1.26 66.16 64.89 0.00

1.52 1.50 1.35 1.35 1.26 66.07 66.07 65.92 65.96 66.05 64.55 64.57 64.57 64.61 64.79 -7.18 -7.03 -7.00 -6.55 -3.50

1.73 66.14

64.56

64.41

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-35.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

CH 240

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS KIRKHAM LANE - MCA2 SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-353

B

Mar 06, 2024 - 9:21am

CH 200

-10.50

DESIGN OFFSETS

64.56

63.68

EXISTING LEVELS

-16.79

0.00 63.68

DESIGN LEVELS

18.95

3.78 3.78 3.93 4.00 4.77 4.85 5.00 5.00 8.50 10.50 11.50

64.41 64.41 64.40 64.39 64.34 64.33 64.32 64.32 63.55 63.94 63.86

65.79 65.82 65.92 65.92 65.91 65.91 65.81 65.78 65.68 65.64 65.54

1.13 65.63 64.50 0.00

65.53 64.32 -3.50

65.42 63.99 -7.00

1.40 1.40 65.35 65.36

-15.83

DESIGN OFFSETS

-10.00 -9.00

63.90

EXISTING LEVELS

63.96 63.96

63.90

DESIGN LEVELS

1.38 1.41 1.52 1.52 1.58 1.58 1.49 1.46 2.12 1.70 1.68

LEVEL DIFFERENCE

1.20

LEVEL DIFFERENCE

1.43

DATUM R.L 59.00

0.00

DATUM R.L 59.00

0.00

Ex Watr


MCB1

-1.8%

D

D

D

D

D

DATUM R.L 59.00

65.75

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-35.dwg

CH 278.06

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS KIRKHAM LANE - MCA2 SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-354

B

Mar 06, 2024 - 9:21am

-0.01 0.00

DESIGN OFFSETS

35.55

66.12 66.12

EXISTING LEVELS

63.90

66.39 66.39

DESIGN LEVELS

1.85

0.27 0.27

LEVEL DIFFERENCE


Issue

-1 0

SCALE 1:100 @ A1 SCALE 1:200 @ A3

1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

20cm

CH 20

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

PHONE : (02) 4654 7777 FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

66.53 66.52 66.52 66.52

66.44 66.44 66.44 66.44 66.44 66.43 66.43 66.42

66.32 66.31 66.31 66.31 66.29 66.26 66.25 66.25

-7.16 -7.01 -6.98 -6.53

0.00 0.02 0.02 0.17 0.25 1.60 1.67 1.82

11.58 12.03 12.06 12.21 13.43 15.93 16.53 17.16

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

MCA1

66.65 66.65 66.65 66.64

66.59 66.59 66.59 66.58 66.58 66.57 66.57 66.57 66.57 66.48 66.47 66.47 66.47 66.46 66.44 66.43 66.43

-7.10 -6.95 -6.92 -6.47

0.00 0.04 0.04 0.19 0.26 1.61 1.69 1.84 1.84 11.59 12.04 12.07 12.22 13.44 15.94 16.54 16.94

-4.0% -3.0%

66.11 66.07 66.22 66.22 66.25 66.31 66.33 66.43

66.45 66.45 66.48 66.58 66.58 66.53 66.53 66.43 66.40

66.37 66.37 66.22 66.26

-0.37 -0.40 -0.25 -0.25 -0.21 -0.13 -0.10 0.00

-0.13 -0.13 -0.10 0.00 0.00 -0.04 -0.04 -0.14 -0.17

-0.28 -0.27 -0.42 -0.38

-0.21 -0.23 -0.24

-3.0%

-0.45 -0.48 -0.33 -0.33 -0.28 -0.19 -0.17 0.00

-3.0%

-4.0%

65.87 65.83 65.98 65.98 66.01 66.07 66.09 66.25

2.5%

-0.23 -0.23 -0.20 -0.10 -0.10 -0.13 -0.13 -0.23

1 in -9.2

-3.0%

66.22 66.22 66.25 66.35 66.35 66.29 66.29 66.19

CH 20.75

-0.40 -0.39 -0.54 -0.50

1 in -6.1

2.5%

66.13 66.13 65.98 66.02

66.48 66.45 66.42

66.69 66.68 66.66 -11.42 -10.32 -9.12

-6.1%

-0.34 -0.35 -0.37

-0.94 -0.98 -1.00 -0.81

-7.7%

66.24 66.21 66.18

-1.25 -1.25 -1.24 -0.92

1 in 5.9

65.44 65.43 65.44 65.73

65.88 65.84 65.81 65.98

66.82 66.81 66.81 66.79

-23.12 -22.49 -21.86 -19.60

-0.54

-0.00

5.3

-0.97

1.5%

66.30

66.84

-25.38

66.85

-0.03 0.02 0.00

-0.21 -0.25 -0.10 -0.09

-0.26

9 1 in

65.74

66.04 66.05 66.02

65.94 65.90 66.04 66.04

66.05

-0.16 -0.32 -0.29

-0.13 -0.14

1 in 3.

CH 40

10 metres

NOT FOR CONSTRUCTION

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 1 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-361

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

66.58 66.56 66.55

-11.48 -10.38 -9.18

DESIGN OFFSETS 66.69 66.68 66.68 66.65

EXISTING LEVELS

-18.95 -18.45 -17.95 -16.14

DESIGN LEVELS

66.86

DESIGN OFFSETS -27.55

EXISTING LEVELS

66.71

0.6%

DESIGN LEVELS

-20.75

66.07 66.03 66.02

66.15 66.15 66.13 66.13

66.31

66.23 66.07 66.11

LEVEL DIFFERENCE

-0.01

18.88 19.81 20.02

13.23 13.74 15.55 15.65

0.00

66.40 66.39 66.39

66.31 66.28

LEVEL DIFFERENCE -0.24

DATUM R.L 61.00

66.79

MCA1

-8.18 -7.37 -6.91

66.44 66.42

66.34

DATUM R.L 61.00

66.79

7.2%

0.1%

-26.96

-0.8%

0.08 0.15

-0.17 -0.20 -0.05 -0.05

-0.21

-0.30 -0.26 0.8% 7.6%

66.06 66.08

65.94 65.90 66.04 66.04

LEVEL DIFFERENCE

-0.14

-10.91 -9.65

66.58

-0.8%

65.98 65.93

66.11 66.10 66.09 66.09

66.06

66.08 66.12

66.26

LEVEL DIFFERENCE -0.11

-20.67

0.8%

19.86 20.99

13.67 14.20 16.15 16.19

66.27

66.38 66.37

66.40

66.31

-6.1% 2.4% 1 in 9.2

0.00

-7.57 -7.10

-9.27

66.42

DATUM R.L 61.00

-0.22

1.8%

-11.30

66.21

DATUM R.L 61.00

-0.20

DESIGN OFFSETS

66.44

DESIGN LEVELS 66.39

EXISTING LEVELS

-12.89

EXISTING LEVELS 66.59

DESIGN LEVELS 2.8% 2.9%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:21am

DESIGN OFFSETS -22.72

0.3%

2.5%

D

CH 60

2.5%

D

MCA1

MCA1


MCA1 2.5%

-3.5%

-3.0%

-4.0%

-3.0%

2.5%

D

0.90 0.86 1.01 1.01 1.05 1.14 1.16 1.20 1.20 0.00 66.60 66.59 66.59 66.59 66.58 66.56 66.55 66.54 66.54 66.54 11.57 12.02 12.05 12.20 13.42 15.92 16.52 17.52 18.02 18.06

67.49 67.45 67.60 67.60 67.63 67.70 67.71 67.74 67.74 66.54

1.15 1.15 1.18 1.28 1.28 1.24 1.24 1.14 1.11 67.84 67.84 67.87 67.97 67.97 67.92 67.92 67.82 67.79 66.69 66.69 66.69 66.69 66.69 66.68 66.68 66.68 66.68 0.00 0.02 0.02 0.17 0.25 1.60 1.67 1.82 1.82

67.77 67.77 67.62 67.66 66.74 66.74 66.74 66.73 -6.54 -6.39 -6.36 -5.91

67.88 67.85 67.82 66.77 66.76 66.75 -10.86 -9.76 -8.56

DESIGN OFFSETS

67.08

EXISTING LEVELS

-34.05

67.06

DESIGN LEVELS

1.11 1.09 1.07

-0.02

LEVEL DIFFERENCE

1.04 1.04 0.89 0.93

DATUM R.L 62.00

MCA1

CH 100

2.5%

-1.2%

1 in -6

-3.0%

-4.0%

-3.0%

2.5%

D

0.19 0.15 0.30 0.30 0.34 0.44 0.46 0.50 0.51 0.00

CH 80

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-362

B

Mar 06, 2024 - 9:21am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

66.74 66.70 66.85 66.85 66.88 66.94 66.96 66.98 66.98 66.48 66.55 66.55 66.55 66.55 66.54 66.50 66.50 66.48 66.48 66.48 11.58 12.03 12.06 12.21 13.43 15.93 16.53 17.53 18.03 18.07

0.45 0.45 0.48 0.59 0.59 0.54 0.54 0.44 0.41 67.09 67.09 67.12 67.22 67.22 67.16 67.16 67.06 67.03 66.63 66.63 66.63 66.63 66.63 66.62 66.62 66.62 66.62 0.00 0.03 0.03 0.18 0.26 1.60 1.68 1.83 1.83

0.31 0.31 0.16 0.20 66.70 66.70 66.70 66.70 -6.82 -6.67 -6.64 -6.19

67.01 67.01 66.86 66.90

67.12 67.09 67.06 66.74 66.73 66.72 -11.14 -10.04 -8.84

0.38 0.36 0.34

66.86 66.98

DESIGN OFFSETS

-32.98

66.56

EXISTING LEVELS

67.01

DESIGN LEVELS

-34.78

-0.45

LEVEL DIFFERENCE

-0.13

DATUM R.L 62.00


Issue

-1 0 1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm 20cm

66.63 66.63 66.63 66.63 66.61 66.59 66.58 66.57 66.57 66.57 66.54 66.54 66.54

11.57 12.02 12.05 12.20 13.42 15.92 16.52 17.52 18.02 18.06 20.52 21.02 21.06

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

-4.0%

PHONE : (02) 4654 7777

1.62 1.58 1.73 1.73 1.78 1.86 1.88 1.92 1.92 0.62 0.40 0.41 0.00

MCA1

66.85 66.85 66.85 66.84 66.77 66.77 66.77 66.77 66.72 66.72 66.72 66.72 66.65 66.65 66.65 66.65 66.64 66.62 66.61 66.61 66.60 66.60 66.58 66.58 66.58 66.58

-6.18 -6.03 -6.00 -5.55 0.00 0.01 0.16 0.24 4.40 4.47 4.62 4.62 11.01 11.46 11.49 11.64 12.86 15.36 15.96 16.96 17.46 17.50 19.96 20.46 20.50 20.60

69.02 68.98 69.13 69.13 69.16 69.22 69.24 69.26 69.26 67.96 67.72 67.72 66.59 66.58

69.35 69.35 69.48 69.48 69.34 69.34 69.24 69.21

69.29 69.29 69.14 69.18

69.40 69.38 69.35

2.37 2.33 2.48 2.48 2.52 2.60 2.62 2.66 2.66 1.36 1.13 1.14 0.01 0.00

2.58 2.58 2.71 2.71 2.62 2.62 2.53 2.50

2.45 2.45 2.30 2.35

2.50 2.49 2.47

-0.39 -0.30 -0.19 0.48

-3.3%

68.25 68.21 68.36 68.36 68.39 68.45 68.47 68.49 68.49 67.19 66.95 66.95 66.54

-3.0%

1.85 1.85 1.88 1.98 1.98 1.94 1.94 1.84 1.81

2.5%

68.60 68.60 68.63 68.73 68.73 68.67 68.67 68.57 68.54

66.90 66.89 66.87

-10.50 -9.40 -8.20

67.51 67.50 67.51 67.82

-3.0% -3.0% 2.5%

1 in -6

-3.0% 2.5%

CH 120

10 metres

NOT FOR CONSTRUCTION

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290 Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 3 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-363

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

66.75 66.75 66.75 66.74 66.74 66.73 66.73 66.73 66.73

0.00 0.02 0.02 0.17 0.24 1.59 1.67 1.82 1.82

1.74 1.74 1.59 1.64

1.80 1.79 1.77

-5.5%

68.54 68.54 68.39 68.43

68.65 68.62 68.59

67.90 67.81 67.70 67.33

2.5%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:21am

SCALE 1:100 @ A1 SCALE 1:200 @ A3

66.79 66.79 66.79 66.79

DESIGN OFFSETS -6.26 -6.11 -6.08 -5.63

EXISTING LEVELS -34.09 -33.58 -33.07 -31.23

DESIGN OFFSETS

66.84 66.83 66.82

LEVEL DIFFERENCE 0.25

EXISTING LEVELS

-10.58 -9.48 -8.28

DESIGN LEVELS 67.40

DESIGN LEVELS

67.15

LEVEL DIFFERENCE

-33.24

-7.7%

2.5%

-10.0%

D

DATUM R.L 62.00

CH 140

2.5% -10.0%

D

DATUM R.L 62.00

MCA1


SCALE 1:100 @ A1 SCALE 1:200 @ A3

Issue

-1 0 1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm 20cm

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

PHONE : (02) 4654 7777

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

MCA1

68.44

68.13 68.08 68.04 67.96 67.95 67.95 67.94 67.77 67.77 67.77 67.67 67.66 67.66 67.66 67.50 67.49 67.49 67.49 67.48 67.46 67.45 67.44 67.44 67.44 67.42 67.41 67.41 67.39 67.39 67.39 67.37 67.36 67.36

-10.50 -9.40 -8.20 -6.18 -6.03 -6.00 -5.55 0.00 0.15 0.23

CH 160

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

3.77 3.85 4.00 4.00

CH 180 9.55 10.00 10.03 10.18 11.40 13.90 14.50 15.50 16.00 16.04 18.50 19.00 19.04 21.50 22.00 22.04 24.50 25.00 25.04

-3.4%

-10.0%

72.06 72.02 72.17 72.17 72.20 72.26 72.28 72.30 72.30 71.00 70.76 70.76 69.63 69.38 69.38 68.25 68.00 68.00 67.36

72.36 72.36 72.26 72.23

72.35 72.48 72.48

72.29 72.29 72.14 72.18

72.40 72.37 72.34

72.79

3.88 3.88 3.91 4.01 4.02 3.94 3.94 3.84 3.82 3.80 3.75 3.90 3.89 3.90 3.95 3.95 3.97 3.96 2.66 2.39 2.38 1.25 0.98 0.98 0.00

4.56 4.53 4.68 4.68 4.72 4.81 4.83 4.86 4.87 3.57 3.34 3.34 2.22 1.99 1.99 0.86 0.64 0.65 0.00

4.69 4.69 4.60 4.57

4.57 4.71 4.71

4.33 4.34 4.19 4.24

4.27 4.29 4.30

4.35

-10.0%

-3.0%

4.06 4.02 4.17 4.17 4.21 4.26 4.27 4.29 4.29 2.99 2.73 2.72 1.59 1.33 1.32 0.19 0.00

-3.0%

-3.4%

71.33 71.29 71.44 71.44 71.47 71.53 71.55 71.57 71.57 70.27 70.03 70.03 68.90 68.65 68.65 67.52 67.17

2.5%

4.27 4.30 4.41 4.41 4.31 4.31 4.21 4.18

4.06 4.07 3.92 3.97

2.5%

71.62 71.65 71.75 71.75 71.63 71.63 71.53 71.50

71.56 71.56 71.41 71.45

5.1%

-3.0% -3.0%

2.5% D

-10.0%

-10.0% D

CH 200

10 metres

NOT FOR CONSTRUCTION

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 4 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-364

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

67.27 67.27 67.27 67.27 67.27 67.28 67.28 67.29 67.29 67.29 67.30 67.31 67.31 67.32 67.33 67.33 67.17

9.56 10.01 10.04 10.19 11.41 13.91 14.51 15.51 16.01 16.05 18.51 19.01 19.05 21.51 22.01 22.05 25.59

DESIGN OFFSETS

67.35 67.35 67.34 67.34 67.32 67.32 67.32 67.32

EXISTING LEVELS

0.00 0.00 0.15 0.23 3.78 3.85 4.00 4.00

DESIGN LEVELS

67.50 67.49 67.49 67.48

D

DESIGN OFFSETS

-6.18 -6.03 -6.00 -5.55

1 in -6.2

EXISTING LEVELS

4.03 4.05 4.07

1 in -7.7

DESIGN LEVELS

71.67 71.64 71.61

-3.0%

LEVEL DIFFERENCE

-19.02

70.86 70.86 70.89 70.99 70.99 70.87 70.87 70.77 70.74 70.57 70.53 70.68 70.68 70.71 70.77 70.78 70.81 70.81 69.51 69.26 69.26 68.13 67.89 67.89 66.91

D

67.64 67.59 67.54

66.98 66.98 66.98 66.98 66.98 66.93 66.93 66.92 66.92 66.77 66.78 66.78 66.78 66.81 66.82 66.83 66.84 66.85 66.85 66.87 66.88 66.88 66.90 66.91 66.91

3.74 3.75 3.60 3.64

3.79 3.78 3.76

.1 1 in -4

-10.50 -9.40 -8.20

0.00 0.00 0.01 0.16 0.23 3.87 3.95 4.10 4.10 9.89 10.34 10.37 10.52 11.74 14.24 14.84 15.84 16.34 16.38 18.84 19.34 19.38 21.84 22.34 22.38

70.81 70.81 70.66 70.70

70.91 70.89 70.86

0.00

2.5%

4.11

-3.3%

-3.0%

72.11

MCA1

67.06 67.06 67.06 67.05

67.13 67.11 67.09

67.73

-3.4%

67.99

3.27 3.27 3.30 3.40 3.40 3.32 3.32 3.22 3.19 3.07 3.04 3.19 3.19 3.23 3.32 3.35 3.38 3.38 2.08 1.85 1.86 0.73 0.49 0.49 0.00

-6.18 -6.03 -6.00 -5.55

-10.50 -9.40 -8.20

67.73

-3.0%

-19.03

70.11 70.11 70.14 70.24 70.24 70.11 70.11 70.01 69.98 69.80 69.76 69.91 69.91 69.94 70.00 70.01 70.04 70.04 68.74 68.49 68.49 67.36 67.12 67.12 66.62

LEVEL DIFFERENCE

3.13 3.13 2.98 3.03 -3.0%

66.84 66.84 66.84 66.84 66.84 66.79 66.79 66.79 66.79 66.72 66.72 66.72 66.72 66.70 66.67 66.67 66.66 66.66 66.66 66.64 66.64 66.64 66.63 66.62 66.62

70.05 70.05 69.90 69.94

2.5%

0.00 0.01 0.01 0.16 0.23 4.10 4.18 4.33 4.33 10.38 10.83 10.86 11.01 12.23 14.73 15.33 16.33 16.83 16.87 19.33 19.83 19.87 22.33 22.83 22.87

66.92 66.92 66.92 66.91

3.1% 1 in 6.7

3.18 3.17 3.15

-23.56

DESIGN OFFSETS

-6.18 -6.03 -6.00 -5.55

LEVEL DIFFERENCE -0.43 -0.35 -0.25 0.36

EXISTING LEVELS

70.16 70.13 70.10

67.73 67.73 67.74 68.05

DATUM R.L 63.00

-0.19

DESIGN LEVELS

66.98 66.97 66.95

68.16 68.08 68.00 67.69

68.02

DATUM R.L 62.00

-0.01

LEVEL DIFFERENCE

-10.50 -9.40 -8.20

-29.74 -29.20 -28.67 -26.72

68.21

68.10

DESIGN LEVELS

-31.69

EXISTING LEVELS 68.11

2.5%

2.5%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:21am

DESIGN OFFSETS -34.23

4.6% 2.5%

-10.0% -10.0%

-10.0%

DATUM R.L 62.00 DATUM R.L 63.00

CH 220

2.5% -10.0%

-10.0%

-10.0%

MCA1

MCA1


SCALE 1:100 @ A1 SCALE 1:200 @ A3

Issue

-1 0 1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

20cm

67.58 67.58 67.58 67.58 67.57 67.55 67.54 67.53 67.53 67.53 67.51 67.50 67.50 67.45 67.44 67.44 67.38 67.36 67.36

CH 224.558

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

PHONE : (02) 4654 7777 FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

4.74 4.75 4.65 4.62 4.59 4.57 4.73 4.73 4.86 5.28 5.32 5.39 5.41 4.11 3.97 3.99 2.86 2.72 2.73 1.60 1.19 1.14 0.01 0.00

-3.1%

73.20 73.20 73.10 73.07 72.98 72.94 73.09 73.09 73.05 73.11 73.13 73.15 73.15 71.85 71.60 71.60 70.47 70.23 70.23 69.10 68.85 68.85 67.72 67.72

4.65 4.78 4.79

MCA1

CH 240

-3.4% -3.0%

-10.0%

68.48 68.46 68.46 68.46 68.41 68.31 68.28 68.24 68.09 68.07 67.91 67.90 67.90 67.82 67.81 67.81 67.76 67.75 67.75 67.80

68.64 68.64 68.64 68.64

3.77 3.85 4.00 4.00

73.13 73.09 73.24 73.24 73.27 73.33 73.35 73.37 73.37 72.07 71.83 71.83 70.70 70.45 70.45 69.32 69.08 69.08 67.95 67.80

73.43 73.43 73.33 73.30

73.42 73.55 73.55

4.65 4.63 4.78 4.78 4.86 5.02 5.07 5.14 5.29 4.00 3.91 3.93 2.80 2.63 2.64 1.51 1.32 1.33 0.20 0.00

4.78 4.79 4.69 4.66

4.71 4.84 4.84

4.42

-3.4%

9.55 10.00 10.03 10.18 11.40 13.90 14.50 15.50 16.00 16.04 18.50 19.00 19.04 21.50 22.00 22.04 24.50 25.00 25.04 26.52

68.71 68.71 68.71

0.00 0.15 0.23

73.25

-3.0%

2.5% -3.0%

-10.0%

-10.0% D

-10.0%

2.5% -1.1%

-10.0% D

-10.0%

CH 249.729

10 metres

NOT FOR CONSTRUCTION

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 5 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-365

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

68.46 68.46 68.45 68.45 68.38 68.36 68.36 68.35 68.19 67.83 67.80 67.76 67.74 67.74 67.64 67.62 67.61 67.51 67.49 67.49 67.67 67.71 67.72 67.72

3.77 3.85 4.00 4.00 7.30 7.76 7.79 7.94 11.40 13.90 14.50 15.50 16.00 16.04 18.50 19.00 19.04 21.50 22.00 22.04 24.50 25.00 25.04 25.07

73.19 73.32 73.32

0.5%

68.54 68.54 68.54

0.4%

68.83

DESIGN OFFSETS -5.55

EXISTING LEVELS

4.35 4.35 4.21 4.27

DESIGN LEVELS

73.10 73.10 72.95 72.99

4.24

4.16

-0.2%

73.12

73.13

LEVEL DIFFERENCE

0.00 0.15 0.23

68.75 68.75 68.75 68.72

-7.26 -7.05 -7.01 -6.40

DESIGN OFFSETS 68.88

EXISTING LEVELS

-10.79

DESIGN LEVELS

68.97

D

-13.31

-3.0%

3.87

DATUM R.L 63.00

73.11

4.56 4.57 4.42 4.47 4.70 4.84 4.84 4.87 4.87 4.78 4.75 4.72 4.69 4.84 4.84 4.98 5.13 5.16 5.21 5.23 3.93 3.75 3.77 2.64 2.53 2.54 1.41 1.21 1.22 0.10 0.00

4.34 4.35 4.37

D

69.24

4.63 4.59 4.74 4.74 4.78 4.87 4.89 4.92 4.92 3.62 3.40 3.40 2.27 2.08 2.09 0.96 0.78 0.79 0.00

72.96 72.96 72.81 72.85 72.95 73.08 73.08 72.96 72.96 72.86 72.83 72.73 72.69 72.84 72.84 72.80 72.87 72.88 72.91 72.91 71.61 71.36 71.36 70.23 69.98 69.98 68.85 68.61 68.61 67.48 67.42

73.00 72.97 72.94

4.10

-1.0%

-21.92

72.21 72.17 72.32 72.32 72.35 72.41 72.43 72.45 72.45 71.15 70.91 70.91 69.78 69.53 69.53 68.40 68.15 68.15 67.36

MCA1

68.40 68.39 68.39 68.38 68.24 68.24 68.24 68.09 68.09 68.08 68.08 68.01 68.00 68.00 68.00 67.82 67.74 67.72 67.69 67.68 67.68 67.61 67.59 67.59 67.45 67.44 67.44 67.39 67.38 67.38 67.42

68.65 68.61 68.57

73.06

-3.1%

9.55 10.00 10.03 10.18 11.40 13.90 14.50 15.50 16.00 16.04 18.50 19.00 19.04 21.50 22.00 22.04 24.50 25.00 25.04

4.76 4.76 4.67 4.64

-3.4%

72.51 72.51 72.41 72.38

-3.0%

67.74 67.74 67.74 67.74

LEVEL DIFFERENCE

4.64 4.78 4.78

-3.88 -3.73 -3.70 -3.25 0.00 0.15 0.23 3.77 3.85 4.00 4.00 7.25 7.70 7.73 7.88 11.40 13.90 14.50 15.50 16.00 16.04 18.50 19.00 19.04 21.50 22.00 22.04 24.50 25.00 25.04 25.60

-10.50 -9.40 -8.20

68.96

-3.1% -3.4%

3.77 3.85 4.00 4.00

72.50 72.63 72.63

LEVEL DIFFERENCE 4.35 4.35 4.20 4.26

2.5%

67.85 67.85 67.84

72.44 72.44 72.29 72.33

DATUM R.L 63.00

4.29 4.31 4.32

-19.00

3.91

-0.5%

0.00 0.15 0.23

68.09 68.09 68.08 68.07

72.55 72.52 72.49

DATUM R.L 63.00

4.38

4.6%

-6.18 -6.03 -6.00 -5.55

68.25 68.21 68.17

DESIGN LEVELS 72.94

73.10

DESIGN LEVELS

-10.50 -9.40 -8.20

EXISTING LEVELS 68.56

EXISTING LEVELS 69.20

LEVEL DIFFERENCE 2.5%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:22am

DESIGN OFFSETS -19.01

DESIGN OFFSETS -25.49

0.7% 2.5% -10.0%

-10.0% -10.0% -10.0%

DATUM R.L 63.00

CH 260

2.5% -10.0%

-10.0% -10.0%

MCA1

MCA1


Issue

-1 0

SCALE 1:100 @ A1 SCALE 1:200 @ A3

1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm

9.55 10.00 10.03 10.18 11.40 13.90 14.50 15.50 16.00 16.04 18.50 19.00 19.04 21.50 22.00 22.04 24.50 25.00 25.04 28.37

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

20cm

PHONE : (02) 4654 7777

DESIGN OFFSETS

CH 280

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

DESIGN OFFSETS

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

EXISTING LEVELS

CH 340

2.5% 0.0%

DESIGN LEVELS

EXISTING LEVELS

DESIGN OFFSETS

CH 320

-3.7%

-10.0% -2.5%

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

73.76

73.66 73.69

DESIGN LEVELS

73.73

73.65 73.68

0.02

0.01 0.01

-0.03

0.02 0.00

2.5%

13.90

10.18 11.40

74.04

73.95 73.98

-10.0%

Ex Drai

CH 360

10 metres

NOT FOR CONSTRUCTION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 6 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-366

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

MCA1

74.07

73.93 73.98

LEVEL DIFFERENCE

0.00 0.03 0.13 0.13 0.12 0.12 0.03

LEVEL DIFFERENCE

0.00 0.03 0.12 0.12 0.12 0.13 0.03 -0.00 0.00 -0.02 0.14 0.14 0.05 0.08

-3.2%

13.90

10.18 11.40

74.07 74.10 74.20 74.20 74.19 74.19 74.09

0.11 0.09 0.24 0.25 0.34 0.81 0.95 1.19 1.33 0.04 0.50 0.65 0.00

DATUM R.L 65.00

73.97 74.00 74.10 74.10 74.10 74.10 74.00 73.97 73.85 73.81 73.96 73.96 73.87 73.93

LEVEL DIFFERENCE

-0.01 -0.04 0.11 0.12 0.15 0.14 0.14 0.12 0.11 0.00

74.07 74.07 74.07 74.08 74.07 74.07 74.06

73.70 73.66 73.81 73.81 73.84 73.90 73.92 73.94 73.94 72.64 72.40 72.40 71.74

0.20 0.20 0.11 0.08

0.14 0.27 0.27

DATUM R.L 66.00

73.97 73.97 73.97 73.98 73.98 73.97 73.97 73.97 73.85 73.82 73.82 73.82 73.82 73.86

73.87 73.83 73.98 73.98 74.01 74.08 74.09 74.12 74.12 74.01

0.00 0.00 0.15 0.23 3.77 3.85 4.00

73.59 73.57 73.57 73.56 73.50 73.10 72.97 72.75 72.61 72.60 71.90 71.75 71.74

74.00 74.00 73.90 73.87

73.95 74.08 74.08

-1.8%

0.00 0.00 0.15 0.23 3.77 3.85 4.00 4.00 7.26 7.71 7.74 7.89 11.40 13.90

EXISTING LEVELS 73.89 73.87 73.87 73.87 73.86 73.94 73.96 73.99 74.01 74.01

DESIGN LEVELS

9.55 10.00 10.03 10.18 11.40 13.90 14.50 15.50 16.00 16.04

0.4%

0.12 0.13 0.03 0.00

-10.0%

74.18 74.18 74.08 74.05

CH 300 DESIGN OFFSETS

74.06 74.05 74.05 74.05

MCA1

9.55 10.00 10.03 10.18 11.40 13.90 14.50 15.50 16.00 16.04 18.50 19.00 19.04

73.80 73.80 73.79 73.79

73.80 73.81 73.81

0.21 0.21 0.06 0.11

-0.3%

3.77 3.85 4.00 4.00

D

EXISTING LEVELS

0.00 0.13 0.12

-3.0%

DESIGN LEVELS

74.04 74.17 74.17

LEVEL DIFFERENCE

4.95 4.93 5.08 5.08 5.16 5.30 5.33 5.39 5.40 4.10 3.93 3.95 2.82 2.64 2.65 1.53 1.34 1.35 0.23 0.00

3.77 3.85 4.00 4.00

0.00 0.15 0.23

73.89 73.89 73.74 73.78

0.55 0.32 0.24

DATUM R.L 66.00

74.04 74.04 74.04

73.46 73.42 73.57 73.57 73.60 73.67 73.68 73.71 73.71 72.41 72.16 72.16 71.03 70.78 70.78 69.65 69.41 69.41 68.28 67.95

LEVEL DIFFERENCE 4.99 4.99 4.90 4.87

MCA1

73.68 73.68 73.68 73.68

74.00 73.97 73.94

-3.0%

0.00 0.15 0.23

68.52 68.50 68.50 68.49 68.45 68.37 68.35 68.32 68.31 68.30 68.23 68.21 68.21 68.14 68.13 68.13 68.07 68.05 68.05 67.95

73.76 73.76 73.66 73.63

-3.4%

68.77 68.77 68.76 68.76

DATUM R.L 66.00

4.81 4.95 4.95

-6.18 -6.03 -6.00 -5.55

73.45 73.66 73.70

-2.3%

3.77 3.85 4.00 4.00

73.75 73.88 73.88

-3.0%

68.94 68.93 68.93

2.5%

0.00 0.15 0.23

DATUM R.L 66.00

4.50 4.50 4.35 4.41

-10.50 -9.40 -8.20

DESIGN OFFSETS

73.69 73.69 73.54 73.58

DATUM R.L 63.00

4.42 4.44 4.46

EXISTING LEVELS

69.20 69.19 69.19 69.17

DESIGN LEVELS 73.80 73.77 73.74

DESIGN LEVELS

-6.18 -6.03 -6.00 -5.55

EXISTING LEVELS 69.38 69.34 69.28

LEVEL DIFFERENCE -3.0%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:22am

DESIGN OFFSETS -10.50 -9.40 -8.20 2.5% 2.5% 2.5%

D

Ex Drai

CH 380

2.5% -10.0%

2.5%

-10.0% D

Ex Drai Ex Drai

MCA1

MCA1


-1.3%

MCA1

MCA1

MCA1 -2.3%

3.0% -3.8%

2.5%

-1.9%

-0.3% 2.5%

Ex Drai

Ex Drai

Ex Drai

-3.6%

3.0% -3.6%

2.5%

-3.3%

Ex Watr

1 in -4 Ex Elec

Ex Drai

DATUM R.L 66.00

DATUM R.L 66.00

2.5% 3.0% -3.7%

-1.3%

2.5% Ex Elec

Ex Drai

0

1

2

4

6

8

0.07 73.24

73.17

73.24 73.27 73.37 73.37 73.43 73.36 73.36 73.26 73.23 73.15 73.18

73.17

DESIGN OFFSETS

13.90

EXISTING LEVELS

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

SCALE 1:100 @ A1 SCALE 1:200 @ A3

CH 440

DESIGN LEVELS

CH 480

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-367

B

Mar 06, 2024 - 9:22am

CH 400

73.14

73.17 73.17 73.17 73.18 73.19 73.19 73.18 73.18 73.17 73.05 73.08 0.00 0.01 0.17 0.24 3.39 3.46 3.62 3.63 3.99 10.18 11.40

DESIGN OFFSETS

13.90

73.17 73.20 73.30 73.30 73.31 73.31 73.21 73.18 73.17 73.07 73.11

73.56 73.51

EXISTING LEVELS

13.90

73.55 73.58 73.68 73.68 73.73 73.73 73.63 73.60 73.54 73.47 73.50 73.55 73.55 73.55 73.56 73.57 73.57 73.59 73.60 73.54 73.40 73.45 0.00 0.01 0.17 0.24 0.76 0.83 0.99 1.00 4.00 10.18 11.40

DESIGN OFFSETS

DESIGN LEVELS

73.24 73.24 73.24 73.25 73.40 73.24 73.24 73.23 73.23 73.13 73.12

LEVEL DIFFERENCE

0.00 0.00 0.15 0.23 2.08 3.77 3.85 4.00 4.00 10.18 11.40

LEVEL DIFFERENCE

0.03

LEVEL DIFFERENCE

0.00 0.03 0.12 0.12 0.12 0.12 0.03 0.00 0.00 0.02 0.02

DATUM R.L 67.00

0.05

DATUM R.L 66.00

0.00 0.03 0.12 0.12 0.16 0.16 0.04 0.00 -0.00 0.07 0.04

DATUM R.L 67.00

0.00 0.03 0.13 0.12 0.03 0.12 0.13 0.03 -0.00 0.02 0.06

Ex Drai

Ex Drai

EXISTING LEVELS

0.00 72.55 18.19

MCA1 -1.5%

2.5% Ex Elec

DESIGN LEVELS

72.55

0.01 -0.07 0.03 0.03 0.06 0.12 0.13 73.26 73.22 73.37 73.37 73.40 73.46 73.48 73.25 73.29 73.34 73.34 73.34 73.34 73.35 9.55 10.00 10.03 10.18 11.40 13.90 14.50

CH 500

MCA1

MCA1

0.4% -1.2%

-0.00 0.12 0.12 0.03 0.13 0.13 0.03 0.00 73.45 73.46 73.46 73.61 73.45 73.44 73.44 73.44 0.00 0.15 0.23 2.08 3.77 3.85 4.00 4.00

CH 460

CH 420

-2.1%

73.45 73.58 73.58 73.63 73.57 73.57 73.47 73.44

0.02 0.07 -0.02 0.00 73.34 73.29 73.23 73.25 -6.18 -6.03 -6.00 -5.55

73.36 73.36 73.21 73.25

-0.01 0.02

13.90

DESIGN OFFSETS

73.45 73.39

72.77

EXISTING LEVELS

73.47 73.44 73.41

0.21 72.99

DESIGN LEVELS

-10.50 -9.40 -8.20

0.00 0.03 0.12 0.12 0.04 0.12 0.12 0.03 -0.00 -0.00 0.01

0.06 73.35

DESIGN OFFSETS

73.12 73.15 73.25 73.25 73.31 73.24 73.24 73.14 73.11 73.00 72.99

0.00 0.01 0.17 0.24 0.76 0.83 0.99 1.00 4.00 10.18 11.40

DESIGN OFFSETS

EXISTING LEVELS

LEVEL DIFFERENCE

73.12 73.12 73.12 73.13 73.27 73.12 73.12 73.11 73.11 73.00 72.99

73.35 73.35 73.36 73.36 73.37 73.37 73.39 73.41 73.34 73.24 73.26

EXISTING LEVELS

DESIGN LEVELS

73.29

73.35 73.38 73.48 73.48 73.54 73.54 73.44 73.41 73.34 73.26 73.29

DESIGN LEVELS

LEVEL DIFFERENCE

13.90

0.00 0.03 0.13 0.12 0.17 0.16 0.04 0.00 -0.00 0.02 0.03

LEVEL DIFFERENCE

0.00 0.00 0.15 0.23 2.08 3.77 3.85 4.00 4.00 10.18 11.40

DATUM R.L 67.00


DESIGN OFFSETS

Issue

-1 0 1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

20cm

CH 509.382

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

PHONE : (02) 4654 7777 FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

70.52

26.85

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

0.00

Ex Elec

70.52

0.46 0.49 0.64 0.67 0.88 1.33 1.45

Ex Coms Ex Watr Ex Elec

-3.0%

73.39 73.35 73.50 73.50 73.53 73.59 73.60

0.01 0.16 0.17 0.48 0.65 0.66 0.58

3.0% -3.2%

CH 527.724

10 metres

NOT FOR CONSTRUCTION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 8 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-368

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

72.93 72.86 72.85 72.83 72.64 72.26 72.16

9.55 10.00 10.03 10.18 11.40 13.90 14.50

73.55 73.68 73.68 73.74 73.68 73.68 73.58

-3.0%

73.54 73.52 73.51 73.26 73.03 73.02 73.00

-0.18 -0.18 -0.32 -0.27

-0.08 -0.12 -0.16

2.5%

73.50 73.50 73.35 73.39

73.60 73.58 73.55

-0.00

2.1%

0.00 0.15 0.23 2.08 3.77 3.85 4.00

73.68 73.67 73.67 73.66

-6.18 -6.03 -6.00 -5.55

DESIGN OFFSETS 73.68 73.69 73.71

EXISTING LEVELS

-10.50 -9.40 -8.20

DESIGN LEVELS 73.89

Ex Drai

73.89

Ex Elec

1 in -4

-23.99

-0.00

Ex Elec

69.79

-3.0%

MCA1

26.38

70.64

73.56 73.56 73.56 73.55 73.49 73.44 73.43 73.43 73.43 73.43 73.42 73.42 73.45 73.23 72.79 72.68

0.00 0.00 0.15 0.23 2.08 3.77 3.85 4.00 4.00 9.55 10.00 10.03 10.18 11.40 13.90 14.50

70.64

73.55 73.58 73.68 73.68 73.74 73.68 73.68 73.58 73.55 73.39 73.35 73.50 73.50 73.53 73.59 73.61

73.50 73.50 73.35 73.39

0.00

-0.01 0.02 0.13 0.13 0.25 0.25 0.25 0.15 0.12 -0.04 -0.07 0.08 0.05 0.30 0.80 0.92

-0.21 -0.21 -0.36 -0.44

0.01 -0.05 -0.11

Ex Coms Ex Elec Ex Watr

69.80

MCA1

73.70 73.71 73.71 73.83

-6.18 -6.03 -6.00 -5.55

73.61 73.58 73.55

-3.0%

29.60

LEVEL DIFFERENCE

-0.06 -0.09 0.06 0.06 0.11 0.29 0.44

Ex Watr

73.35 73.31 73.46 73.46 73.49 73.55 73.57

3.0% -3.2%

73.41 73.40 73.40 73.40 73.38 73.26 73.13

LEVEL DIFFERENCE -0.20 -0.06 -0.06 0.16 0.16 0.16 0.07 0.04

73.60 73.63 73.66

-10.50 -9.40 -8.20

0.00

3.0% -3.2%

9.55 10.00 10.03 10.18 11.40 13.90 14.50

DATUM R.L 66.00

0.06 0.06 -0.09 -0.07 -3.0%

73.52 73.65 73.65 73.70 73.65 73.65 73.55 73.52

73.46 73.46 73.31 73.35

DATUM R.L 65.00

-0.00 0.05 0.06 0.12 2.5%

73.71 73.71 73.71 73.54 73.49 73.49 73.48 73.48

73.40 73.40 73.40 73.42

73.56 73.57 73.54 73.51

DESIGN LEVELS -3.0%

0.00 0.15 0.23 2.08 3.77 3.85 4.00 4.00

EXISTING LEVELS 73.56 73.52 73.48 73.39

DESIGN OFFSETS

-6.18 -6.03 -6.00 -5.55

-11.46 -10.50 -9.40 -8.20

EXISTING LEVELS 2.5%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:22am

SCALE 1:100 @ A1 SCALE 1:200 @ A3

73.82

DESIGN LEVELS

73.82

LEVEL DIFFERENCE

-17.81

2.9% 2.5%

Ex Elec

1 in -4

DATUM R.L 65.00

CH 520

2.5%

2.5% 1 in -4

MCA1


SCALE 1:100 @ A1 SCALE 1:200 @ A3

Issue

-1 0 1cm at full size

0 1 2 4 6 8

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm 20cm

PHONE : (02) 4654 7777

CH 540

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

2.15 2.18 2.28 2.27 2.31 2.30 2.30 2.20 2.17 2.17 2.14 2.29 2.29 2.34 2.43 2.46

2.5%

73.07 73.10 73.20 73.20 73.24 73.23 73.23 73.13 73.10 72.90 72.86 73.01 73.01 73.04 73.10 73.12

2.08 2.08 2.08 1.93 1.98

2.5%

73.04 73.01 73.01 72.86 72.90

MCA1

0.00 1.00 1.00 1.15 1.23 1.92 2.77 2.85 3.00 9.55 10.00 10.03 10.18 11.40 13.90 14.50

71.05 71.02 71.02 71.01 71.01 70.98 70.95 70.95 70.94 70.75 70.74 70.74 70.74 70.72 70.66 70.65

72.86 72.89 72.99 72.99 73.02 72.99 72.99 72.89 72.67 72.63 72.78 72.78 72.75 72.68 72.67

1.85 1.88 1.98 1.98 2.04 2.04 2.04 1.95 1.92 1.88 2.03 2.03 2.03 2.02 2.02

-3.0%

CH 560

-3.0% -2.3%

CH 580

10 metres

NOT FOR CONSTRUCTION

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290 Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 9 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-369

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

70.91 70.91 70.92 70.92 70.93 70.92 70.92 70.92 70.92 70.73 70.72 70.72 70.72 70.70 70.67 70.66

0.00 0.00 0.15 0.23 0.42 0.77 0.85 1.00 1.00 9.55 10.00 10.03 10.18 11.40 13.90 14.50

DESIGN OFFSETS

70.96 70.93 70.93 70.93 70.91

EXISTING LEVELS

-7.40 -6.18 -6.03 -6.00 -5.55

DESIGN LEVELS

2.07 2.07

DESIGN OFFSETS

73.12 73.10

EXISTING LEVELS

71.05 71.03

2.51 2.48 2.63 2.63 2.69 2.81 2.84

2.49 2.52 2.63 2.63 2.67 2.67 2.67 2.57 73.14 73.10 73.25 73.25 73.28 73.34 73.36

73.31 73.34 73.44 73.44 73.48 73.47 73.47 73.37

2.35 2.34 2.34 2.19 2.24

DESIGN LEVELS

70.63 70.62 70.62 70.61 70.59 70.53 70.52

70.81 70.81 70.81 70.81 70.80 70.80 70.80 70.79

73.28 73.25 73.25 73.10 73.14

2.37 2.37

LEVEL DIFFERENCE

9.55 10.00 10.03 10.18 11.40 13.90 14.50

0.00 0.00 0.15 0.23 0.42 0.77 0.85 1.00

70.93 70.91 70.91 70.91 70.90

73.36 73.34

DATUM R.L 66.00

-10.50 -9.90

LEVEL DIFFERENCE

0.00

-1.7%

70.37

LEVEL DIFFERENCE 1.79 1.80 1.96 1.98 2.16 2.54 2.63

-3.0%

70.37

73.34 73.30 73.45 73.45 73.48 73.54 73.56

MCA1

-7.40 -6.18 -6.03 -6.00 -5.55

70.99 70.98

-2.3%

27.25

71.55 71.50 71.49 71.47 71.32 71.00 70.92

D

9.55 10.00 10.03 10.18 11.40 13.90 14.50

-0.8%

0.80

0.2%

73.50

DATUM R.L 66.00

0.09

DESIGN OFFSETS -10.50 -9.90

EXISTING LEVELS

72.70

73.34

DATUM R.L 66.00

-0.15 -0.19 -0.35 -0.43

DESIGN LEVELS

0.00

73.25

73.31 73.30 73.14 73.14

DESIGN LEVELS

-5.55

EXISTING LEVELS 73.46 73.49 73.50 73.57

LEVEL DIFFERENCE -3.0%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:22am

DESIGN OFFSETS -33.65 -32.94 -32.80 -30.09

2.5% 2.5% -2.5%

DATUM R.L 66.00

CH 600

1 in -4 2.5%

D

MCA1

MCA1


SCALE 1:100 @ A1 SCALE 1:200 @ A3

Issue

-1 0 1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

20cm

PHONE : (02) 4654 7777

EXISTING LEVELS

DESIGN OFFSETS

CH 620

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

EXISTING LEVELS

DESIGN OFFSETS

2.5%

CH 640

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

-3.0%

0.04 0.03 0.06 0.16 0.16 0.12 0.12 0.03

1 in -4

79.73 79.76 79.79 79.89 79.89 79.90 79.90 79.80

MCA1

CH 880

0.15 0.04 0.06 0.03 0.03

80.49 80.63 80.65 80.65 80.71 80.96 80.94 80.94 80.93 80.93

-7.40 -6.18 -6.03 -6.00 -5.55 0.00 1.00 1.00 1.15 1.23

80.13 80.20

-10.50 -9.90

80.78 80.81 80.84 80.94 80.94

80.76 80.73 80.73 80.58 80.62

80.83 80.82

-0.18 -0.13 -0.09 0.01 0.01

0.26 0.09 0.08 -0.08 -0.09

0.70 0.62

0.00

2.5%

CH 900

10 metres

NOT FOR CONSTRUCTION

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 10 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-370

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

DESIGN LEVELS

79.70 79.73 79.73 79.74 79.74 79.77 79.77 79.77

LEVEL DIFFERENCE

0.00 1.00 1.00 1.15 1.23 2.78 2.85 3.01

LEVEL DIFFERENCE 79.87

1 in -4

79.71 79.68 79.68 79.53 79.57

LEVEL DIFFERENCE

79.56 79.64 79.62 79.50 79.54

DATUM R.L 74.00

0.50 0.43

2.5%

79.78 79.77

-3.0%

79.87

DESIGN OFFSETS -14.34

-0.01 -0.01 0.02 0.12 0.12 0.12 0.13 0.03

0.02 -0.02 -0.02 -0.08 -0.03

0.00 0.16 0.13

EXISTING LEVELS

-7.40 -6.18 -6.03 -6.00 -5.55

DESIGN LEVELS DESIGN LEVELS

79.28 79.34

-2.5% 3.0% 1.2%

-10.50 -9.90

CH 624.466 LEVEL DIFFERENCE

0.00

LEVEL DIFFERENCE

79.14

LEVEL DIFFERENCE

78.87 78.90 78.93 79.03 79.03 79.05 79.05 78.95

78.84 78.81 78.81 78.66 78.70

DATUM R.L 75.00

78.88 78.91 78.91 78.91 78.91 78.92 78.92 78.92

78.82 78.84 78.83 78.74 78.73

78.72 78.92 78.91

DATUM R.L 74.00

1.37 1.40 1.50 1.50 1.54 1.52 1.52 1.42 1.27 1.23 1.39 1.39 1.37 1.33 1.33

DATUM R.L 67.00

0.00 1.00 1.00 1.15 1.23 2.78 2.85 3.01

-7.40 -6.18 -6.03 -6.00 -5.55

EXISTING LEVELS 78.72 78.76 78.78

72.82 72.85 72.95 72.95 72.97 72.95 72.95 72.85 72.62 72.58 72.73 72.73 72.70 72.64 72.62

DESIGN LEVELS

-3.0%

79.14

MCA1

DESIGN OFFSETS -11.31 -10.50 -9.90

71.46 71.45 71.45 71.44 71.44 71.44 71.43 71.43 71.42 71.35 71.35 71.35 71.34 71.33 71.30 71.30

2.5%

-13.07

DATUM R.L 67.00

1.26 1.29 1.39 1.40 1.43 1.42 1.42 1.32 1.17 1.14 1.29 1.29 1.33 1.42 1.44

-3.0%

72.97 73.00 73.10 73.10 73.12 73.10 73.10 73.00 72.77 72.73 72.88 72.88 72.91 72.98 72.99

DATUM R.L 67.00

1.42 1.45 1.55 1.55 1.59 1.57 1.57 1.47 1.44 1.32 1.28 1.43 1.44 1.42 1.39 1.38

0.00 1.00 1.00 1.15 1.23 1.92 2.77 2.85 3.00 9.55 10.00 10.03 10.18 11.40 13.90 14.50

DESIGN OFFSETS

71.72 71.71 71.71 71.70 71.70 71.69 71.68 71.68 71.68 71.60 71.59 71.59 71.59 71.58 71.56 71.55

DESIGN LEVELS 72.80 72.83 72.93 72.93 72.96 72.93 72.93 72.83 72.80 72.60 72.56 72.71 72.71 72.68 72.62 72.60

MCA1

EXISTING LEVELS

0.00 1.00 1.00 1.15 1.23 1.92 2.77 2.85 3.00 9.55 10.00 10.03 10.18 11.40 13.90 14.50

EXISTING LEVELS 71.39 71.38 71.38 71.38 71.38 71.37 71.36 71.36 71.36 71.36 71.28 71.28 71.28 71.28 71.26 71.23 71.22

DESIGN LEVELS -2.5%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:22am

DESIGN OFFSETS 0.00 1.00 1.00 1.15 1.23 1.92 2.77 2.85 3.00 3.00 9.55 10.00 10.03 10.18 11.40 13.90 14.50 -3.0%

-3.0%

CH 920

3.1% 0.1%

MCA1

MCA1

MCA1


Issue

-1 0

SCALE 1:100 @ A1 SCALE 1:200 @ A3

1cm at full size

0 1 2 4 6 8

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm 20cm

DESIGN OFFSETS

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

PHONE : (02) 4654 7777

CH 940

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

CH 980 84.37 84.39 84.39 84.39 84.40

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

2.5%

-0.19 -0.19 -0.16 -0.07 -0.07

MCA1

0.00 1.00 1.00 1.15 1.23

-7.40 -6.18 -6.03 -6.00 -5.55

87.61 87.64 87.64 87.65 87.65

87.33 87.38 87.39 87.39 87.41

87.45 87.48 87.51 87.61 87.61

87.43 87.40 87.40 87.25 87.29

87.50 87.49

-0.16 -0.16 -0.13 -0.04 -0.04

0.10 0.01 0.00 -0.15 -0.13

0.57 0.40

0.00

2.5%

86.37 86.40 86.43 86.53 86.53

0.11 0.03 0.02 -0.13 -0.11

1 in -4

86.35 86.32 86.32 86.17 86.21

86.93 87.09

-10.50 -9.90

86.16

-0.20 -0.19 -0.16 -0.06 -0.07

0.05 -0.03 -0.04 -0.19 -0.17

0.83 0.66

0.00

-0.16 -0.11 -0.08 0.02 0.02

0.07 -0.10 -0.10 -0.25 -0.23

0.85 0.69

1 in -4

CH 1020

10 metres

NOT FOR CONSTRUCTION

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 11 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-371

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

86.56 86.60 86.60 86.60 86.60

DESIGN OFFSETS 0.00 1.00 1.00 1.15 1.23

EXISTING LEVELS 86.24 86.29 86.30 86.30 86.32

DESIGN LEVELS

-7.40 -6.18 -6.03 -6.00 -5.55

-3.0%

0.84 0.68

CH 1000

86.42 86.41

DESIGN OFFSETS

85.59 85.73

EXISTING LEVELS 86.16

DESIGN LEVELS

-15.87

85.29 85.32 85.35 85.45 85.45

LEVEL DIFFERENCE

-10.50 -9.90

85.49 85.51 85.51 85.52 85.52

LEVEL DIFFERENCE

0.00

0.00 1.00 1.00 1.15 1.23

85.27 85.24 85.24 85.09 85.13

85.35 85.33

83.93

LEVEL DIFFERENCE

85.03

MCA1

85.21 85.27 85.28 85.28 85.30

84.52 84.68

83.93

83.07 83.10 83.13 83.23 83.23

DATUM R.L 81.00

0.00

DATUM R.L 79.00

85.03

-0.17 -0.16 -0.13 -0.04 -0.04

-7.40 -6.18 -6.03 -6.00 -5.55

-10.50 -9.90

83.23 83.22 83.22 83.21 83.21

83.04 83.01 83.01 82.86 82.90

83.12 83.11

81.76

DATUM R.L 77.00

-16.09

84.20 84.23 84.26 84.36 84.36

2.5%

0.00 1.00 1.00 1.15 1.23

LEVEL DIFFERENCE

0.08 -0.02 -0.03 -0.18 -0.16

1 in -4

84.17 84.14 84.14 83.99 84.03

-2.7%

84.09 84.16 84.17 84.17 84.19

CH 960

0.87 0.71

-16.15

DESIGN OFFSETS

84.25 84.24

LEVEL DIFFERENCE 0.00

0.00 1.00 1.00 1.15 1.23

EXISTING LEVELS

83.38 83.52

DESIGN LEVELS 82.80

MCA1

82.97 83.11 83.12 83.12 83.13

82.27 82.41

81.76

1 in -4

-7.40 -6.18 -6.03 -6.00 -5.55

EXISTING LEVELS 82.80

LEVEL DIFFERENCE -0.14 -0.07 -0.04 0.07 0.07 0.12 0.13 0.03 0.00

-7.40 -6.18 -6.03 -6.00 -5.55

-10.50 -9.90

-15.93

DESIGN LEVELS

-10.50 -9.90

-16.32

81.93 81.96 81.99 82.09 82.09 82.04 82.04 81.94 81.91

DATUM R.L 80.00

0.25 0.00 -0.03 -0.18 -0.19 -3.0%

82.07 82.03 82.03 82.02 82.01 81.92 81.92 81.91 81.91

81.90 81.87 81.87 81.72 81.76

2.5%

0.00 1.00 1.00 1.15 1.23 2.78 2.85 3.00 3.01

81.65 81.87 81.90 81.90 81.95

DATUM R.L 78.00

0.87 0.75

1 in -4

-7.40 -6.18 -6.03 -6.00 -5.55

81.98 81.96

DATUM R.L 76.00

0.00

DESIGN OFFSETS

81.10 81.21

DESIGN LEVELS 80.74

EXISTING LEVELS

-10.50 -9.90

EXISTING LEVELS 80.74

DESIGN LEVELS -3.0% -3.0%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:22am

DESIGN OFFSETS -15.46 1 in -4 2.5% 2.5%

-3.0%

CH 1040

-3.0%

MCA1

MCA1

MCA1


Issue

-1 0

SCALE 1:100 @ A1 SCALE 1:200 @ A3

1cm at full size

0 1 2 4 6 8

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B 100% DETAIL DESIGN ISSUE FOR REVIEW 06.03.24 MDM TRC

A DRAFT ISSUE FOR REVIEW 01.08.23 MDM TRC

Date Drawn Approved

Description

10cm 20cm

EXISTING LEVELS

DESIGN OFFSETS

CH 1060

PHONE : (02) 4654 7777

LEVEL DIFFERENCE LEVEL DIFFERENCE LEVEL DIFFERENCE

CH 1100

Client

CAMDEN COUNCIL

70 CENTRAL AVENUE ORAN PARK, NSW 2570

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

DESIGN LEVELS

EXISTING LEVELS

DESIGN OFFSETS

0.00 -0.03 -0.03 -0.01 0.15 0.14 -0.01 0.01 -0.00 0.03 -0.00 0.12 0.12 0.13 0.13 0.03 0.00

2.5%

-3.0%

CH 1130

10 metres

NOT FOR CONSTRUCTION

ACOR Consultants Pty Ltd The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290 Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 12 Drawn Date Scale

JER MAR 2023 1:100

Designed Project No.

SP

A1

NSW210622

Q.A. Check

C106-372

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

DATUM R.L 87.00

92.13 92.10 92.08 92.02 91.99 91.99 91.84 91.88 91.99 92.02 91.99 92.12 92.12 92.13 92.13 92.03 92.00

-3.0%

92.13 92.13 92.11 92.03 91.83 91.85 91.85 91.87 91.99 91.99 91.99 92.00 92.00 92.00 92.00 92.00 92.00

DATUM R.L 86.00

-0.11 -0.11 -0.09 0.01 0.01

-3.0%

-8.93 -8.78 -8.18 -5.68 -4.46 -4.31 -4.28 -3.83 -0.01 -0.01 0.00 0.14 0.22 1.77 1.84 1.99 1.99

DESIGN LEVELS 90.69 90.72 90.75 90.85 90.85

2.5%

90.80 90.83 90.83 90.84 90.84

MCA1

MCA1

CH 1080 91.76 91.76 91.74 91.70 91.67 91.67 91.67 91.66 91.68 91.68 91.68 91.68 91.68 91.67 91.67 91.66 91.66

91.76 91.73 91.72 91.66 91.62 91.62 91.47 91.51 91.62 91.65 91.64 91.75 91.75 91.78 91.78 91.68 91.65

0.00 -0.03 -0.03 -0.04 -0.05 -0.04 -0.19 -0.15 -0.07 -0.04 -0.04 0.06 0.06 0.11 0.12 0.02 -0.01

-2.5%

0.00 0.96 0.96 1.11 1.18

-9.31 -9.19 -8.59 -6.09 -4.87 -4.72 -4.69 -4.24 -0.06 -0.06 0.00 0.09 0.17 1.72 1.79 1.94 1.94

89.74 89.77 89.77 89.78 89.78

0.00 1.00 1.00 1.15 1.23

DESIGN OFFSETS

0.00 -0.05 -0.05 -0.06 -0.07 -0.06 -0.21 -0.16

89.61 89.64 89.67 89.77 89.77

89.40 89.43 89.47 89.50 89.53 89.54 89.54 89.55

EXISTING LEVELS

90.81 90.76 90.74 90.68 90.65 90.65 90.50 90.54

-0.12 -0.13 -0.10 -0.00 -0.01

89.40 89.66 89.65 89.59 89.55 89.55 89.40 89.44

DESIGN LEVELS

90.81 90.81 90.79 90.74 90.72 90.71 90.71 90.70

MCA1

0.00 0.24 0.18 0.08 0.02 0.02 -0.13 -0.11

LEVEL DIFFERENCE

-10.23 -10.01 -9.41 -6.91 -5.69 -5.54 -5.51 -5.06

2.5%

-0.15 -0.15 -0.12 -0.03 -0.03

DESIGN OFFSETS -10.70 -10.50 -9.90 -7.40 -6.18 -6.03 -6.00 -5.55

EXISTING LEVELS

88.53 88.56 88.59 88.69 88.69

DATUM R.L 83.00

0.00 0.57 0.51 0.33 0.10 0.01 0.00 -0.15 -0.13

DESIGN LEVELS

88.68 88.71 88.71 88.72 88.72

DESIGN LEVELS 88.02 88.58 88.58 88.57 88.51 88.48 88.48 88.33 88.37

LEVEL DIFFERENCE

0.00 1.00 1.00 1.15 1.23

EXISTING LEVELS 88.02 88.02 88.07 88.24 88.40 88.46 88.47 88.47 88.50

2.5%

Date

TRC 28.02.24

Dwg. No. Issue

B

Mar 06, 2024 - 9:22am

DESIGN OFFSETS -10.70 -10.70 -10.50 -9.90 -7.40 -6.18 -6.03 -6.00 -5.55 2.5%

-3.0% 2.3%

DATUM R.L 84.00 DATUM R.L 87.00

CH 1120

0.4%

MCA1

MCA1


1

2

4

6

8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-36.dwg

0

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS LIZ KERNOHAN DRIVE - MCA1 SHEET 13 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-373

B

Mar 06, 2024 - 9:22am

SCALE 1:100 @ A1 SCALE 1:200 @ A3


MC01

2.5%

-3.0%

-3.0%

MC01

2.5%

D

DATUM R.L 67.00

2.97

2

4

6

8

-0.33 73.65 73.99 8.00

-0.01 -0.01 0.11 0.11

-0.12

73.38 73.39 73.40 73.41

73.61 8.00

73.49

-0.10 -0.13 -0.02 -0.02

-0.01 -0.00 -0.11 -0.08 -0.03

3.05 3.26 3.60 3.65

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-38.dwg

1

CH 60

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS RHEINBERGERS CIRCUIT - MC01 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-381

B

Mar 06, 2024 - 9:22am

0

73.39 73.39 73.27 73.28 73.37 73.40 73.40 73.37 73.36 73.40

CH 20

SCALE 1:100 @ A1 SCALE 1:200 @ A3

2.5%

-3.65 -3.60 -3.26 -3.05 0.00

73.50 73.47 73.44

DESIGN OFFSETS

-3.1%

73.59 73.54 73.49

69.23

EXISTING LEVELS

-2.8%

-8.00 -6.90 -5.70

3.87 73.10

DESIGN LEVELS

8.00

72.88 72.87 72.99 72.99 69.25 69.24 69.23 69.23 3.05 3.26 3.60 3.65

72.99 72.99 72.87 72.88 72.97 69.28 69.28 69.28 69.29 69.33 -3.65 -3.60 -3.26 -3.05 0.00

73.10 73.07 73.04 69.21 69.23 69.24 -8.00 -6.90 -5.70

DESIGN OFFSETS

3.63 3.63 3.76 3.76

LEVEL DIFFERENCE

3.71 3.71 3.58 3.60 3.64

LEVEL DIFFERENCE

3.89 3.85 3.80

DATUM R.L 70.00

-0.09 -0.07 -0.05

2.5%

73.28 73.26 73.39 73.39

2.5%

-3.0%

DATUM R.L 66.00

EXISTING LEVELS

73.43 73.42 73.54 73.54 73.44 73.43 73.44 73.44 3.05 3.26 3.60 3.65

MC01

CH 77.235

D

DESIGN LEVELS

0.09 0.09 -0.01 -0.01 -0.01 73.51 73.51 73.49 73.50 73.55 -3.65 -3.60 -3.26 -3.05 0.00

MC01 -3.0%

73.60 73.60 73.48 73.49 73.54

-0.04 -0.08 -0.13 73.71 73.68 73.65

DESIGN OFFSETS

73.75 73.76 73.78

EXISTING LEVELS

-8.00 -6.90 -5.70

73.30

DESIGN LEVELS

70.33

2.84 2.82 2.94 2.94 73.08 73.06 73.19 73.19 70.23 70.24 70.24 70.24

73.19 73.19 73.06 73.08 73.17

LEVEL DIFFERENCE

CH 40

2.5%

2.5%

-3.5%

-1.7%

DATUM R.L 71.00

8.00

-8.00 -6.90 -5.70

DESIGN OFFSETS

3.05 3.26 3.60 3.65

70.02 70.04 70.07

EXISTING LEVELS

70.11 70.11 70.12 70.12 70.18

73.30 73.27 73.24

DESIGN LEVELS

-3.65 -3.60 -3.26 -3.05 0.00

3.28 3.22 3.17

LEVEL DIFFERENCE

3.08 3.07 2.94 2.95 2.98

2.5%


MC02

2.5%

0.2%

0.00

DESIGN OFFSETS

3.05 3.50 3.53 3.68 4.90 7.40 8.00 8.32

73.37

EXISTING LEVELS

73.38 73.34 73.34 73.37 73.46 73.51 73.52 73.52

73.37

DESIGN LEVELS

73.38 73.34 73.49 73.49 73.52 73.58 73.60 73.52

-0.00

LEVEL DIFFERENCE

-0.00 -0.00 0.15 0.12 0.06 0.07 0.08 0.00

DATUM R.L 71.00

MC02

CH 41

2.5%

0.1%

0.00

DESIGN OFFSETS

3.05 3.50 3.53 3.68 4.90 7.40 8.00 8.24

73.35

EXISTING LEVELS

73.36 73.32 73.32 73.46 73.46 73.51 73.51 73.52

73.35

DESIGN LEVELS

73.36 73.32 73.47 73.47 73.50 73.56 73.57 73.52

0.00

LEVEL DIFFERENCE

-0.01 -0.01 0.15 0.01 0.04 0.05 0.06 0.00

DATUM R.L 71.00

MC02

CH 40

2.5%

-2.3%

2.5%

-2.2%

1 in -4

D

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-39.dwg

CH 20

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROAD CROSS SECTIONS GRIMES AVENUE - MC02 SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:100

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-391

B

Mar 06, 2024 - 9:22am

72.04 12.64

72.04

0.00

-0.72 -0.77 -0.62 -0.62 -0.61 -0.14 0.03 72.99 72.95 73.10 73.10 73.13 73.19 73.20 73.71 73.72 73.72 73.72 73.73 73.33 73.17 3.05 3.50 3.53 3.68 4.90 7.40 8.00

73.66 73.66 73.67 73.67 73.67 -3.65 -3.60 -3.26 -3.05 0.00

DESIGN OFFSETS

73.65 73.65 73.65

EXISTING LEVELS

-8.00 -6.90 -5.70

73.20 73.18 73.15

DESIGN LEVELS

73.09 73.09 72.97 72.98 73.05

-0.45 -0.48 -0.51

LEVEL DIFFERENCE

-0.57 -0.57 -0.70 -0.68 -0.61

DATUM R.L 69.00


LEGEND 100

KERB RETURN CONTROL LINE PROPOSED ROAD DESIGN KERB RETURN CONTROL LABEL

MK01

EXISTING BOUNDARY PROPOSED BOUNDARY

80

100

CT 20

120

136.43

40

P

CT

1

CAMDEN VALLEY WAY

20

CTP 5.62

EXISTING SERVICES

P

8 7 .96 CT

51 .3

80

0.00

60

MK21

P8 5.2 9

PROPOSED UTILITIES

P CT

20

CAMDEN VALLEY WAY

0.00

40

MK24

5

4.2

P3

CT

30 71.

60

80

40.

39

9

CTP 93.3

100

113.30

40 CT P

MK22

60

CTP 57.54 60

MK23

CT 69.

73

40 TC 42. 96

ET

80

20

HILDE R TRE

100

120

0.00 0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-401

B

Mar 06, 2024 - 9:23am

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-40.dwg

125.39


65.83 66 .00

100

65.8

0

LEGEND KERB RETURN CONTROL LINE

KIRKHAM LAN E

PROPOSED ROAD DESIGN KERB RETURN CONTROL LABEL

65.90

MK01

EXISTING BOUNDARY PROPOSED BOUNDARY

60

66

.10

TC 50.66 66

PROPOSED UTILITIES 66.00

.20

EXISTING SERVICES

40 66 .30

66.10

CT 35.64

CTP 24 .65 CTP 24 .67

0.00

20

5.51

66 .20

66. 3

0

95

16.

2

20

22.03

0.00

5.65

66.

30

.20

16.5 3

66

.3 11

0

.0 11

MK13 68. 20

68 .10

00

68.

80

.70

.50 67

67

67

.40

67

.30

.20

66

.7 66

.80

66

0

66

.60

.50

20

0

66.30

66.

66. 10

66.4

.90

.00

.10

.60

90

67.

67.

67

67

67

67

66

MK12

CAMDEN VALLEY WAY

.00 66

90 65.

80 65.

70 65.

60 65.

50 65.

40 65.

CAMDEN VALLEY WAY 66.30

.90

.00

68

67

.80

67

.70

67

.60

67

.50

67

.40

67

11

.30 MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved 20cm

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-40.dwg

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:200

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-402

B

Mar 06, 2024 - 9:23am

66.10

65.90

0.00 66.00

66.30 66.20

LIZ KERNOHAN DRIVE

5.65 06.03.24

10cm

.30 67

100% DETAIL DESIGN ISSUE FOR REVIEW

1cm at full size

0

Client

B

0

.2 67

-1

19.60

NOT FOR CONSTRUCTION North

Description

14.7 6

20 metres

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

0

0.00

4.92

16

66 .8

4

12

66.30 66.20

8

66.10

4

66.00

2

65.90

0

66 .70

9.8

16.9 5

20

22.58

SCALE 1:200 @ A1 SCALE 1:400 @ A3

.60

.10

.30

66

.00

0

.50

40

67

0

66

66.

66

.90 66

65.8

0

66.30

0

65.7

0

.10

65.6

65.5 0

66

6 5 .4

66.0

65.9 0

66.20

MK11

67

MK14


LEGEND 100

KERB RETURN CONTROL LINE PROPOSED ROAD DESIGN KERB RETURN CONTROL LABEL

MK01 71.30

EXISTING BOUNDARY

71.40

PROPOSED BOUNDARY

71.50 71.60 71.70

PROPOSED UTILITIES

71.80

71.90 72.00

71.60

72.10

71.70 71.80

EXISTING SERVICES

72.20

73

.20

71.90

72.30

72.00

72.40

0 73.1

VE N ES A GR IM

1 9.5

6.34

3.17

.02 28

0.00

73.10

0 72.9

72.80

72.90

25

.00

72.70

20

73

72.70 72.60

73. 73.4500

68

.00

73

72.50

15

73.00

72.40

TC

MK03

12.

72.60

72.30

R E RG U B N I E RH

1 9 .9

IT U IRC C S

0.0

73.00

73.40

0

73.20

73.00

0

3.17

0.0

0 73.60

0

.40 73

73.70

MK04

1

0

73.20

73.00

9.5

73 .5

72.90

3.9 9

6.34

73.4

73.10

28

73.50

72.80

.02

.90

73.3

72

73.70

7.97

12

73.60

.68

72.50

.10

73

72.20

0.0 0

UE

72.10

MK01

50 CTP 2. 6 5.7 T C

MK02 73.5

0

73.40

73.40

1

0

73.40 73.20

4 5.9

73.50 73.4 0

73.3

73.30

73.10

73.50

11.96

73.30 0

73.5

73.40

73.2

0

73.30 73.6 0

73.40

73.30

73.1

0

LIZ

73.7 0

KE RN

AN OH

LIZ

KE

0

OH

73.10

73.8

AN

E

IV

DR

73.60

RN

0 73.0

73.50

73.20

DR

IV

E

73.00

0 73.7 73

.90 73.80

0

2

4

8

KERB RETURN PLAN (KR03) AND (KR04)

SCALE 1:200

SCALE 1:200

12

16

20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:200

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-403

B

Mar 06, 2024 - 9:23am

0

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-40.dwg

73.9

SCALE 1:200 @ A1 SCALE 1:400 @ A3

KERB RETURN PLAN (KR01) AND (KR02)


VIP RL 66.40 CH 74.42m

CREST RL 66.26 CH 72.23m

VIP RL 65.69 CH 2.78m SAG RL 65.69 CH 3.92m VIP RL 65.69 CH 4.69m D

DATUM R.L 63.4

65.65

MK21 PROFILE A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

SCALE 1:40 @ A1 SCALE 1:80 @ A3 SCALE 1:200 @ A1 SCALE 1:400 @ A3

0

400

800

3600

4800

6400

0

2

4

8

12

16

8000mm 20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PROFILES SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-411

B

Mar 06, 2024 - 9:23am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-41.dwg

65.20 136.43

65.21 120

65.85

65.22 65.22 99.42 100

66.10 66.09

65.05 85.29

66.23

65.01

66.25

R = -100

80

66.23 65.02 60

66.17 65.14 51.31

66.15 65.17 49.42

66.05 65.30 40

65.85 65.33 20

65.70 65.70 65.69 65.69 65.70 65.70 65.35 65.35 65.36 65.36 65.36 65.36 1.82 2.78 3.73 4.69 5.62 5.64

CHAINAGE

65.35

EXISTING LEVELS

G = -1.22%

R = 25.35

0

65.71

DESIGN LEVELS

R = -55

66.26

R = -693

G = 1.02%

64.99

HORIZONTAL GEOMETRY

K = 22.36 L = 50

74.42

VERTICAL GEOMETRY

K=3.27 K=1.69 L=1.91L=1.91 G=-0.7% G=-0.11%


VIP RL 66.47 CH 118.71m

VIP RL 66.17 CH 72.57m

VIP RL 66.04 CH 24.20m

D D D

K = 50.92 L = 48.38

K = 127.5 L = 48.38

K = 14.42 L = 10

G = 0.64%

G = 1.34%

VERTICAL GEOMETRY

G = 0.27%

G = 1.22%

DATUM R.L 63.4

L = 55.67

MK22 PROFILE A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40 SCALE 1:40 @ A1 SCALE 1:80 @ A3 SCALE 1:200 @ A1 SCALE 1:400 @ A3

0

400

800

3600

4800

6400

0

2

4

8

12

16

8000mm 20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PROFILES SHEET 2 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-412

B

Mar 06, 2024 - 9:23am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-41.dwg

66.56 66.54 125.39

66.54 66.52 123.71

66.48 66.49 66.46 66.47 118.71 120

66.44 66.40 113.71

66.35 66.19 100

66.33 66.13 96.76

66.23 65.84 80

66.20 65.67 72.57

66.18 65.62 69.73

66.15 65.64

65.61 48.39

60

65.42 65.42 40 40.39

66.11

65.12 34.25

66.08 66.08

65.99 65.17 24.2

66.05

65.95

CHAINAGE

65.19

EXISTING LEVELS

R = -100

20

65.75

DESIGN LEVELS

R = -15

65.23

R = -55

0

HORIZONTAL GEOMETRY


VIP RL 65.77 CH 99.57m

VIP RL 65.87 CH 72.15m

VIP RL 66.09 CH 52.11m

VIP RL 66.42 CH 6.69m

D

G = -0.71%

K = 37.2 L = 27.43

G = -0.5%

K = 24.87 L = 10

G = -0.37%

VERTICAL GEOMETRY

K = 14.42 L = 10

G = -1.11%

G = -1.4%

DATUM R.L 63.8

K = 213.99 L = 27.43

L = 42.96

65.31 113.3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-41.dwg

65.37 65.37 99.57 100

MK23 PROFILE A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40 SCALE 1:40 @ A1 SCALE 1:80 @ A3 SCALE 1:200 @ A1 SCALE 1:400 @ A3

0

400

800

3600

4800

6400

0

2

4

8

12

16

8000mm 20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PROFILES SHEET 3 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-413

B

Mar 06, 2024 - 9:23am

65.46 93.39

65.70

65.60 85.86

65.77 65.76

65.71 80

65.79

65.73 72.15

65.82

65.78 65.78 65.79 65.81 57.11 57.54 58.43 60

65.85

65.85 52.11

65.90

65.92 47.11

66.04 66.03 66.02 66.01

66.13

65.87 42.96

66.09

66.16

65.91 40

66.18

66.30 20

66.32

66.46 11.69

66.38

66.48 6.69

66.42

66.50

CHAINAGE

1.69

66.51

EXISTING LEVELS

R = -100

R = -27

66.51

DESIGN LEVELS

66.49

R = -50

0

HORIZONTAL GEOMETRY


MCB1 (RL66.50) (CH76.92)

CREST RL 66.50 CH 58.80m

VIP RL 66.50 CH 56.30m MC03 (RL66.50) (CH57.20)

VIP RL 66.37 CH 43.80m SAG RL 66.39 CH 43.80m

MCB1 (RL66.46) (CH33.06)

VIP RL 66.50 CH 31.30m

SAG RL 66.50 CH 28.80m DATUM R.L 63.6

G = -1%

G = 1%

65.38

65.34

80

87.96

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-41.dwg

65.64 71.3

66.50

65.56 65.55 58.8 60

66.50 66.50

65.60 56.3

66.49

65.44 53.8

66.48

65.40 46.3

66.40

65.39 43.8

66.39

65.38 65.37 40 41.3

65.32 33.8

66.41 66.40

R = 14

66.47

65.23 31.3

66.49

65.25 28.8

66.50

65.29 20

CHAINAGE

65.34

EXISTING LEVELS

0

66.50

DESIGN LEVELS

66.50

R = 14

MK24 PROFILE SCALE 1:40 @ A1 SCALE 1:80 @ A3 SCALE 1:200 @ A1 SCALE 1:400 @ A3

0

400

800

3600

4800

6400

0

2

4

8

12

16

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

8000mm 20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PROFILES SHEET 4 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-414

B

Mar 06, 2024 - 9:23am

HORIZONTAL GEOMETRY

K=5 L=5

66.50

G = 0%

VERTICAL GEOMETRY

K = 2.5 L=5

66.50

K=5 L=5


VIP RL 65.93 CH 63.10m

VIP RL 65.98 CH 59.23m

VIP RL 66.33 CH 34.73m CREST RL 66.28 CH 34.96m

VIP RL 65.89 CH 16.93m

CREST RL 65.90 CH 8.56m

VIP RL 65.91 CH 5.62m

D

D

G = -1.25%

VERTICAL GEOMETRY

G = -0.19%

G = 0.6%

K = 14.26 L = 11.31

K = 10.7 L = 11.31

K=5 L = 14.59

G = 1.5%

VERTICAL GEOMETRY

G = -1.41%

G = -2.13%

DATUM R.L 62

D

G = -1.45%

DATUM R.L 63.8

K = 10 K=1 L = 0.35 L = 0.68

L = 15.02

800

3600

4800

6400

0

2

4

8

12

16

65.99 65.98 65.98 65.97 65.93 65.93 65.92 65.87 63.98 63.98 63.99 64.00 64.05 64.05 64.06 64.10 59.05 59.23 59.41 60 62.76 63.1 63.44 65.83

66.10 64.12 50.66

66.23 63.95 42.03

66.25 63.54 40

66.28 66.28 64.12 64.07

66.22 64.39 27.44

R = -300

34.73 35.64

66.18 66.18 64.34 64.34 24.65 24.67

66.11 64.47 20

65.81

CHAINAGE

R = -300

64.76

65.82 65.41 22.58

65.85 65.38

EXISTING LEVELS

R = 0.1

MK11 PROFILE

MK12 PROFILE

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-41.dwg

400

DESIGN LEVELS

R = -15.45

8000mm

20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PROFILES SHEET 5 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-415

B

Mar 06, 2024 - 9:23am

0

20

65.87 65.37 16.93

65.90 65.79 11.27

65.90 66.22 5.62

CHAINAGE

66.30

EXISTING LEVELS

0

65.87

DESIGN LEVELS

SCALE 1:40 @ A1 SCALE 1:80 @ A3 SCALE 1:200 @ A1 SCALE 1:400 @ A3

HORIZONTAL GEOMETRY

R = -14

0

HORIZONTAL GEOMETRY


VIP RL 66.08 CH 14.75m

VIP RL 66.23 CH 4.92m

VIP RL 66.47 CH 16.52m

VIP RL 66.07 CH 5.51m D

D

DATUM R.L 63.3

3600

4800

6400

0

2

4

8

12

16

G = -0.61%

G = -1.59%

66.32

66.46

14.75

19.6

66.05

66.09 9.83

66.24 66.27

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-41.dwg

800

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

8000mm 20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PROFILES SHEET 6 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-416

B

Mar 06, 2024 - 9:23am

400

66.45 0

MK14 PROFILE

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40 0

4.92

22.03

CHAINAGE

MK13 PROFILE

SCALE 1:40 @ A1 SCALE 1:80 @ A3 SCALE 1:200 @ A1 SCALE 1:400 @ A3

R = -13

66.35

66.62 65.68

20

66.56 65.57

16.52

66.46 65.33

11.01

CHAINAGE

66.27 65.18

5.51

EXISTING LEVELS

66.11 64.91

EXISTING LEVELS

66.03

DESIGN LEVELS

64.87

DESIGN LEVELS

HORIZONTAL GEOMETRY

K = 10.06 L = 9.83

66.09

R = -13

K = 11.33 L = 9.83

66.15

VERTICAL GEOMETRY

0

HORIZONTAL GEOMETRY

K = 11.56 L = 11.01

G = -2.46%

VERTICAL GEOMETRY

G = 2.72%

G = 0.6%

K = 3.59 L = 11.01

G = 3.67%

DATUM R.L 64.5


VIP RL 73.28 CH 3.17m

D

K = 4.63 L = 6.34

G = -0.93%

VERTICAL GEOMETRY

K = 3.09 L = 6.34

G = 0.44%

G = 2.49%

K = 1.7 L = 6.34

G = -0.81%

K = 1.47 L = 6.34

G = -4.53%

VERTICAL GEOMETRY

G = -0.21%

K = 1.99 L = 7.97

G = 1.68%

VERTICAL GEOMETRY

K = 1.57 L = 7.97

G = 5.68%

K = 10.28 L = 9.06

G = 0.59%

G = -1.37%

R = 2.95R = -3.85

G = -0.49%

HORIZONTAL GEOMETRY

G = 2.78%

G = 2.94%

G = 4.82%

VERTICAL GEOMETRY

K = 2.77 L = 9.06

DATUM R.L 69.5

DATUM R.L 71.5

DATUM R.L 67.3

K = 1.28 K = 1.18 L = 2.41 L = 2.41

VIP RL 73.09 CH 9.51m

VIP RL 73.38 CH 3.17m

D

DATUM R.L 66.6

CREST RL 73.30 CH 8.38m VIP RL 73.31 CH 9.51m

VIP RL 73.36 CH 11.96m

VIP RL 72.91 CH 3.99m

VIP RL 72.97 CH 23.49m

CREST RL 73.00 CH 17.59m

VIP RL 73.02 CH 14.43m

VIP RL 72.72 CH 3.62m

VIP RL 72.60 CH 1.21m

D

L = 4.14

0

2

4

8

12

16

MK01 PROFILE

MK02 PROFILE

MK03 PROFILE

MK04 PROFILE

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

A1 Horizontal Scale 1 : 200 A1 Vertical scale 1 : 40

73.28 71.37 12.68

73.30 72.10 9.51

73.30 72.81 6.34

73.26 3.17

0

CHAINAGE

73.38

73.20 73.61

73.06 73.65 12.68

73.12 73.65 9.51

73.23 73.62 6.34

73.34 73.62 3.17

73.38 73.64

EXISTING LEVELS

0

73.43 68.91 15.94

73.32 68.90 11.96

73.13 68.93 7.97

72.96 68.99

CHAINAGE

DESIGN LEVELS

R = -9.45

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-41.dwg

6400

CHAINAGE

HORIZONTAL GEOMETRY

R = -9.45

8000mm 20 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

KERB RETURN ALIGNMENT PROFILES SHEET 7 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-417

B

Mar 06, 2024 - 9:23am

4800

3.99

28.02

3600

EXISTING LEVELS

72.88

23.49

800

DESIGN LEVELS

69.08

69.08

18.96 20

400

HORIZONTAL GEOMETRY

R = -9.45

0

72.91

68.91

14.43

0

72.96

68.72 68.77

9.9

SCALE 1:40 @ A1 SCALE 1:80 @ A3 SCALE 1:200 @ A1 SCALE 1:400 @ A3

72.99 72.99

68.54

CHAINAGE

72.98

68.41

EXISTING LEVELS

72.89

EXISTING LEVELS

72.56 72.61 72.66 72.66 72.71 72.75 72.78

DESIGN LEVELS

68.29 68.31 68.30 68.30 68.29 68.30 68.31

HORIZONTAL GEOMETRY

0 1.21 2.41 2.5 3.62 4.82 5.76

DESIGN LEVELS

R = -12.45


CT P8 5.2 9

60

LEGEND 100

KERB RETURN CONTROL LINE PROPOSED ROAD DESIGN KERB RETURN CONTROL LABEL

MK01

CAMDEN VALLEY WAY

EXISTING BOUNDARY

100

PROPOSED BOUNDARY

CT P

5 1 .31

MK24

PROPOSED UTILITIES

20

MK21

EJ

SC

.96

CT P 87

SC

DJ

SC

SC

DJ

SC

40

SC

EXISTING SERVICES

SC

SC

EJ

EJ

SC

SC

SC

DJ

SC

SC

DJ

SC

80

SC SC

EJ

40 EJ

Y

A YW

SC SC

SC

C

SC

P7 CT

DJ

DJ

1.3

0

SC

CAMDEN VA LLEY WAY

N

DE M A

E L L VA

SC

SC

EJ

SC

MK22 66.0

0

MK23

5

4.2

P3

T TREE ER S HILD

CT P4

0.3

9

80

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

ROUNDABOUT JOINTING SETOUT PLAN

NOT FOR CONSTRUCTION

SCALE 1:100 Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROUNDABOUT CENTRAL ISLAND JOINTING PLAN Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-501

B

Mar 06, 2024 - 9:24am

CT

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-50.dwg

60

CTP 93.3 9

40


CONCRETE NOTES

CONCRETE PAVEMENT NOTES

1.

CP1.

PROVIDE JOINTS AS DETAILED ON SHEET C11.01.

CP2.

JOINTS REQUIRE ON GOING MAINTENANCE TO ENSURE LONG TERM PERFORMANCE OF THE SLAB. JOINTS AND SEALANTS SHOULD BE INSPECTED AND REPAIRED AS NECESSARY AS PART OF THE ONGOING MAINTENANCE PROGRAM.

ALL SAWCUT JOINTS ARE TO BE FORMED USING AN EARLY-ENTRY SAWCUT SYSTEM SUCH AS 'SOFFCUT'. SAWCUTS TO BE FORMED AS SOON AS THE CONCRETE HAS HARDENED SUFFICIENTLY THAT IT WILL NOT BE DAMAGED BY SAWING. THE REQUIRED TIMING OF THE SAWCUT IS SUBJECT TO ON-SITE CONDITIONS AND AS SUCH IS THE RESPONSIBILITY OF THE CONTRACTOR, HOWEVER AS A GUIDE, EARLY-ENTRY SAWING CAN USUALLY BE UNDERTAKEN UPON COMPLETION OF POWER FLOATING.

CURING OF ALL CONCRETE IS TO BE ACHIEVED BY KEEPING SERVICES CONTINUOUSLY WET FOR A PERIOD OF 3 DAYS, AND PREVENTION OF LOSS OF MOISTURE FOR A TOTAL OF 7 DAYS FOLLOWED BY A GRADUAL DRYING OUT. APPROVED SPRAYED ON CURING COMPOUNDS THAT COMPLY WITH AS3799 MAY BE USED WHERE FINISHES WILL NOT BE AFFECTED (REFER MANUFACTURER'S SPECIFICATION). POLYTHENE SHEETING OR WET HESSIAN MAY BE USED TO RETAIN CONCRETE MOISTURE WHERE NOT PROTECTED FROM WIND AND TRAFFIC.

CP6.

ANY DEFECTS IN THE CONCRETE PAVEMENT ARE TO BE REFERRED TO THE SUPERINTENDENT FOR REVIEW.

CP7.

THE CONTRACTOR SHALL TAKE MEASURES TO PROTECT THE CONCRETE PAVEMENT FROM CONSTRUCTION TRAFFIC AND OTHER CONSTRUCTION LOADS.

CP8.

WHERE STEEL FIBRE REINFORCEMENT HAS BEEN SPECIFIED IT IS TO BE OF THE SIZE, TYPE AND DOSAGE RATE SPECIFIED. NO SUBSTITUTION IS TO BE MADE WITHOUT APPROVAL OF THE ENGINEER. ALL STEEL FIBRE REINFORCED CONCRETE SHALL BE MANUFACTURED, SUPPLIED AND INSTALLED IN ACCORDANCE WITH THE MANUFACTURER'S SPECIFICATIONS.

THE ENGINEER SHALL BE GIVEN 24 HOURS NOTICE FOR REINFORCEMENT INSPECTION AND CONCRETE SHALL NOT BE DELIVERED UNTIL FINAL APPROVAL OBTAINED.

300 WIDE BARRIER KERB

1500 200mm THICK CONCRETE ANULUS WITH SL82 MESH AT 50mm TOP COVER 2%

150

DEEP LIFT ASPHALT

300 300 MIN.

11.

150

PROVIDE MIN. 500 DEEP TOPSOIL/ GARDEN MIX

300

SMZ

THICKEN ASPHALT TO MINIMUM 150mm BELOW MOUNTABLE ANNULUS

PROVIDE 'BIDIM A64' FILTER FABRIC OR APPROVED EQUIVALENT

MIN. 150mm THICK DGB 20

300

SCALE 1:10

125 THK CONCRETE (25MPa) WITH BROOM FINISH SL82 MESH CENTRAL

BAR GRADE AND TYPE 17 N20 - 250 SPACING IN mm

DEEPEN KERB PROFILE TO TOP OF SMZ AS REQUIRED

12.

REINFORCEMENT IS REPRESENTED DIAGRAMMATICALLY AND NOT NECESSARILY IN TRUE PROJECTION.

13.

FABRIC SHALL BE LAPPED 2 TRANSVERSE WIRES PLUS 50mm. BUNDLED BARS SHALL BE TIED TOGETHER AT 30 BAR DIAMETER CENTRES WITH 3 WRAPS OF THE WIRE.

100Ø SUBOSIL DRAINAGE PIPE WRAPPED IN GEOFABRIC FILTER SOCK

ROUNDABOUT ANNULUS DETAIL - TYPE E TO CAMDEN COUNCIL SD112

'N' DENOTES DEFORMED BAR, 500MPa GRADE, NORMAL DUCTILITY 'R' DENOTES ROUND BAR, 250MPa GRADE, NORMAL DUCTILITY 'SL' DENOTES SQUARE MESH, DEFORMED BAR, 500MPa GRADE, LOW DUCTILITY

NOMINAL BAR SIZE IN mm

ROUNDABOUT ANNULUS DETAIL NOTES: 1. ALL DIMENSIONS IN MILLIMETRES. U.N.O 2. CONCRETE TO HAVE 32MPa COMPRESSIVE STRENGTH (F'c) AT 28 DAYS AND SLUMP OF 60mm. 3. MESH TO HAVE A MIN 300mm LAP LENGTH AND MIN 50 COVER UNLESS SHOWN OTHERWISE. 4. ALL MOUNTABLE KERB FACES TO BE PAINTED REFLECTIVE WHITE.

SUITABLE FILTER MATERIAL (REFER SPEC No. 230)

REINFORCEMENT SYMBOLS:

NUMBER OF BARS IN GROUP

CENTRE ISLAND TO BE LANDSCAPED BY OTHERS

DEEP LIFT ASPHALT SMZ

KERB TYPE AS SPECIFIED

VARIES

300

COMPACTED SUBGRADE

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-51.dwg

THE FINISHED CONCRETE SHALL BE A DENSE HOMOGENOUS MASS, COMPLETELY FILLING THE FORMWORK THOROUGHLY EMBEDDING THE REINFORCEMENT AND FREE OF STONE POCKETS. ALL CONCRETE INCLUDING SLABS ON GROUND AND FOOTINGS SHALL BE COMPACTED WITH MECHANICAL VIBRATORS.

PROVIDE ISOLATION JOINT

GRANULAR BEDDING LAYER

SCALE 1:10 @ A1 SCALE 1:20 @ A3

0

100

200

400

SCALE 1:20 @ A1 SCALE 1:40 @ A3

0

200

400

800

SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

500

1000

2000

600

800

TYPICAL MEDIAN/SPLITTER ISLAND DETAIL (SM KERB)

1000mm

SCALE 1:20 1200

1600

3000

4000

2000mm

5000mm

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

ROUNDABOUT AND SPLITTER ISLAND DETAILS

Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-511

B

Mar 06, 2024 - 9:24am

CONCRETE SIZES SHOWN DO NOT INCLUDE THICKNESSES OF APPLIED FINISHES.

230

CP5.

SCALE 1:50

25

10.

DOWELS ARE TO BE STRAIGHT, TO THE LENGTH SPECIFIED AND FREE FROM MILL SCALE, RUST AND OIL

SUB SOIL DRAINAGE

425

9.

CP4.

ROUNDABOUT TYPICAL CROSS SECTION

200

8.

ALL REINFORCEMENT SHALL BE FIRMLY SUPPORTED ON MILD STEEL PLASTIC TIPPED CHAIRS, PLASTIC CHAIRS OR CONCRETE CHAIRS AT NOT GREATER THAN 1 METRE CENTRES BOTH WAYS. BARS SHALL BE TIED AT ALTERNATE INTERSECTIONS. IN EXPOSURE CONDITIONS GREATER THAN B1 USE ONLY PLASTIC CHAIRS.

REFER DETAIL BELOW

B) ROUND DOWELS TO BE GRADE 250 BAR IN ACCORDANCE WITH AS 3679.1-2010

NO ADMIXTURES SHALL BE USED IN CONCRETE UNLESS APPROVED IN WRITING.

PAVEMENT SURFACE

2%

150 MIN.

7.

A) SQUARE DOWELS TO BE GRADE 300 BAR IN ACCORDANCE WITH AS 3679.1-2010

PROJECT CONTROL TESTING SHALL BE CARRIED OUT IN ACCORDANCE WITH AS10120.

℄

2%

170

6.

DOWEL GRADE

1500mm REFER LANDSCAPE PLANS FOR DETAILS

100

5.

CP3.

PROVIDE MIN. 0.5m DEEP TOPSOIL/GARDEN MIX

BARRIER KERB 300 WIDE

30

4.

READYMIX CONCRETE SUPPLY SHALL COMPLY WITH AS1379.

Ø25000mm

1500mm

240

3.

CONCRETE TO COMPLY WITH THE FOLLOWING: 28 DAY COMPRESSIVE STRENGH - F'c = 32MPa MAX 28 DAY SHRINKAGE - 600 MICROSTRAIN

Ø28000mm

300

2.

ALL WORKMANSHIP AND MATERIALS SHALL COMPLY WITH AS 3600, CURRENT EDITIONS WITH AMENDMENTS EXCEPT WHERE VARIED BY THE CONTRACT DOCUMENTS.


LEGEND 100

DRIVEWAY CONTROL LINE PROPOSED ROAD DESIGN EXISTING SURVEY DRIVEWAY CONTROL LABEL

MD01

EXISTING BOUNDARY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

5.53 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

0.00

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

VIP RL 63.68 CH 20.55m

20 /

/

/

VIP RL 64.12 CH 12.97m

2 21.9 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

VIP RL 64.95 CH 6.61m

MCA2 (RL65.16) (CH0.00)

MD02

VIP RL 65.17 CH 6.58m

MAKE SMOOTH CONNECTION TO EXISTING SURFACE

/

0.00

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

KIRKHAM LANE

/

/

/ /

/

/ /

/ /

/

/ /

/

/ /

/ /

/

/

/ /

/

/ /

/

/

/

/ / /

/ / /

DATUM R.L 62.4

/ / / / /

160

K = 0.64 L=7

G = -2.66%

K = 0.25 L=2

K = 0.21 L=2

G = -10.66%

/ / / /

G = -0.94%

/

180

MD01

G = -2.07%

/

K = 0.2 L=2

G = -3.19%

VERTICAL GEOMETRY

18.07

/

G = -13.04%

DATUM R.L 62

/ /

/ /

L = 18.07

/ /

MAKE SMOOTH CONNECTION TO EXISTING SURFACE

L = 5.53

L = 16.39

/

/ / /

HORIZONTAL GEOMETRY

/ /

/ /

/ / /

/ /

/ /

63.68 63.67

63.79 63.75

65.07

/

65.20 65.20

/

65.35

/

64.02

/

64.05

/

64.58

/

64.82

/

65.16

/

64.98

/

DESIGN LEVELS / /

/ /

63.68 63.67

64.12 64.12 5.53 5.58

63.58 63.60

64.23 0

64.06

64.02 18.07

/

64.03

/

16.47

/

64.06

/

9.47

/

64.07

/

7.61

/

64.10

/

64.35

/

5.61

/ /

/ / /

/

SCALE 1:200 @ A1 SCALE 1:400 @ A3

0

2

4

8

12

16

Client

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

DRIVEWAY PROFILE - MD02

A1 Horizontal Scale 1 : 100 A1 Vertical scale 1 : 20

A1 Horizontal Scale 1 : 100 A1 Vertical scale 1 : 20

21.55 21.92

NOT FOR CONSTRUCTION North

-1

DRIVEWAY PROFILE - MD01

20 metres

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

7.58

0

SCALE 1:200

19.55 20

/

CHAINAGE

DRIVEWAY (MD01) AND (MD02) PLAN

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

DRIVEWAY (MD01) AND (MD02) PLAN AND PROFILES Drawn

Date

Scale

JER

MAR 2023

1:200

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-601

B

Mar 06, 2024 - 9:25am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-60.dwg

/

EXISTING LEVELS


150 200

2300 200

850

850

200 PLINTH BEYOND

N12-150 TOP, 50 COVER BOTH WAYS 200

850

350

850

350

850

N12-150 STARTER BARS

CJ

CJ

CJ

270 270

500

3-L11TM

CJ 800

350

N12-150 TOP, 50 COVER BOTH WAYS

N12-150 STARTER BARS N12-150 BOTH WAYS, 50 COVER TO TREADS

CJ

CJ

CJ

2000

300

300

2000

200

CJ

200 200

850

200

350

N12-150 TOP, 50 COVER BOTH WAYS

1200

2600

3800 3-L11TM

3-L11TM 3-L11TM

350

850

200

850

350

850

2600

3-L11TM

SL102 MESH TOP, 50 COVER POLYSTYRENE VOID FORMER CUT TO SUIT, 200MIN WALL THICKNESS

FORM VOIDS WITH 500x850x800 HIGH POLYSTYRENE BLOCKS

350

350

2-L11TM

2-L11TM

FORM VOIDS WITH 500x850x800 HIGH POLYSTYRENE BLOCKS

500

500

3-L11TM

SECTION

1

SCALE 1:20

-

350 1200

FOOTING PLAN

150 200

SCALE 1:20 FOOTING 200 THICK REINFORCE WITH SL102 MESH TOP THROUGHOUT , 50 COVER FOOTING TO BEAR ON WELL COMPACTED BASE COURSE OF EXISTING PAVEMENT

850

200

850

200 150 N12-150 BOTH WAYS, CENTRAL

DENOTES POLYSTYRENE BLOCKS ABOVE SLAB BASE DENOTES FULL DEPTH VOID FOR ELECTRICAL SERVICES

1200

CJ

850 VOID

200

850 VOID

CJ

N12-150 STARTER BARS

200 CJ

CJ

CJ

CJ

200

200

200

CJ

N12-150 BOTH WAYS, CENTRAL

N12-150 STARTER BARS

1080

2300

CJ

N12-150 STARTER BARS

2-L11TM 900

-

150 200

850

200

200

850

SECTION

2

SCALE 1:20

-

200 150

1 -

EXTEND N12-150 UP FOR RAISED PLINTH N12-150 BOTH WAYS, CENTRAL 150 200 500

FORM VOIDS WITH 500x850x800 HIGH POLYSTYRENE BLOCKS

CJ

N12-150 STARTER BARS

SCALE 1:20 200 MINIMUM CONCRETE THICKNESS REINFORCE WITH N12-150 TOP BOTH WAYS HANDRAILS SHOWN INDICATIVELY. MONOWILLS OR EQUIVALENT AS PER STANDARD RMS DETAILS

CJ

CJ N12-150 STARTER BARS CJ 200

CJ

200

CJ

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C106-70.dwg

HOUSING PLATFORM PLAN

N12-150 BOTH WAYS, CENTRAL 1200

-

200 150

800

3

500

200

N12-150 TOP, 50 COVER BOTH WAYS

HANDRAILS AS SPECIFIED

200

3-L11TM N12-150 STARTER BARS 150 200

3-L11TM 500

300

500

200 150

2000

SCALE 1:20 @ A1 SCALE 1:40 @ A3

0

200

400

800

1200

1600

2000mm

Client North

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

3

SCALE 1:20

-

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

B

SECTION

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

TCS PLINTH DETAIL

Drawn

Date

Scale

JER

MAR 2023

1:20

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C106-701

B

Mar 06, 2024 - 9:25am

800

800

1700

500 VOID

2

3-L11TM

2-L11TM


ADJOINS SHEET 2

LEGEND PROPOSED BOUNDARY EXISTING DP BOUNDARY EXISTING STORMWATER EASEMENT EXISTING SEWER EASEMENT

PROPOSED PROPERTY ACQUISITION

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20

0.00

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

80 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

TC 84.03

/

/

/

/

40

/

/

/

/

200 /

183.84 CTP 183.87

/

180

/

170.08

/

160

/

140

/

120

/

/

/

/

/

/

CAMDEN VA L

/

/

LOT 11, D.P.827115 - APPROXIMATE LAND ACQUISITION 9757m²

/

/

/

/

/

LEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-001

B

Mar 06, 2024 - 9:25am

/

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


ADJOINS SHEET 3

ADJOINS SHEET 1

LEGEND PROPOSED BOUNDARY EXISTING DP BOUNDARY EXISTING STORMWATER EASEMENT EXISTING SEWER EASEMENT

PROPOSED PROPERTY ACQUISITION

LOT 11, D.P.827115 - APPROXIMATE LAND ACQUISITION 9757m²

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

340

TC 344.60

/

320

360 CT 360.02

/

297.63 300

380

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

289.31

400

/

/

/

/

/

/

/

/

/

/

/

280

420

/

/

/

/

/

/

/

/

/

/

/

/

/

260

440

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

240

480 /

236.26

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220 220.07 CT

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

183.84 CTP 183.87

/

/

/

/

/

/

/

/

180

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

500

LOT 11, D.P.827115 - APPROXIMATE LAND ACQUISITION 9757m²

EXISTING SEWER EASEMENT TO BE EXTINGUISHED.

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100 102.83 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

80

CT 71.44

60 /

/

/

/

/

/

/

/

/

LOT 1, D.P.914674 APPROXIMATE LAND ACQUISITION 51m²

/

/

/

/

/

/

/

/

/

/

/

LOT 2, D.P.1103162 - APPROXIMATE LAND ACQUISITION 1564m² .

/ / /

/ / / / /

/

/ / / / / /

/ / / / / /

/ / /

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-002

B

Mar 06, 2024 - 9:25am

/ /

ADJOINS SHEET 3

0.00

/

/

/

/

/

/

/

/

/

/

/

/

HILDE

/

/

/

/

/

/

/

/

/

/

R STR

20 ADJOINS SHEET 1

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

/

/

/

/

/

EET

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 35. 97 40 SCALE 1:500 @ A1 SCALE 1:1000 @ A3


/

/

/

/ /

/

/

LEGEND

/

/

/ /

/ /

/

/

/

/

/

/

/ /

/

/

ADJOINS SHEET 5

/

ADJOINS SHEET 5

/

/

/

160

/

/ /

/

/

/

/

/

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

KIRKHAM LANE

EXISTING STORMWATER EASEMENT

/

/

/

/

/

/

/

/

/

/

/

180

EXISTING DP BOUNDARY

/

/

/

/

/

/

/

/

/

/

EXISTING SEWER EASEMENT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

PROPOSED BOUNDARY

/

/

/

/

PROPOSED PROPERTY ACQUISITION

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LOT 11 D.P.1103895 - APPROXIMATE LAND ACQUISITION 3382m²

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LOT 11, D.P.827115 - APPROXIMATE LAND ACQUISITION 9757m² .

240

800

780

760

740

720

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

640

255.48 257.25 260

700

/ / /

/

660

/

/

/

/

/

/

/

/

/

/

/

680

671.96 CT 674.84

/

/ / / / /

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

/

/

667.41

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 269.56

278.06 0.00 TC 0.05

CAMDEN VALLEY WAY /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

CAMDEN VALLEY WAY

20

40.00

LOT 301, D.P.1143646 - APPROXIMATE LAND ACQUISITION 738m² .

LOT 101, D.P.631430 - APPROXIMATE LAND ACQUISITION 6300m²

ADJOINS SHEET 6 / /

5

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

/

0

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-003

B

Mar 06, 2024 - 9:26am

100

120

ADJOINS SHEET 6

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

80

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

CT 59.76 60


ADJOINS SHEET 3

LEGEND PROPOSED BOUNDARY EXISTING DP BOUNDARY EXISTING STORMWATER EASEMENT EXISTING SEWER EASEMENT

PROPOSED PROPERTY ACQUISITION

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

940

920

900

840

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

820

880

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

945.79

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

800

860 / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 864.55

LOT 101 D.P.1143373 - APPROXIMATE LAND ACQUISITION 3382m²

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

CAMDEN VALLEY WAY

/

LOT 162 D.P.1087243 - APPROXIMATE LAND ACQUISITION 246m²

/ / /

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-004

B

Mar 06, 2024 - 9:26am

ADJOINS SHEET 3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

LOT 301, D.P.1143646 - APPROXIMATE LAND ACQUISITION 738m² .


LEGEND PROPOSED BOUNDARY EXISTING DP BOUNDARY EXISTING STORMWATER EASEMENT EXISTING SEWER EASEMENT

PROPOSED PROPERTY ACQUISITION

0.00 / /

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

20

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

40

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / /

/ / / / / / / / / / /

/ / / / /

/

/

/

/ /

/

/ /

/

/

80

/

/

KIRKHAM LANE

/

/ / /

/ / /

/ / /

/ / / / / / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LOT 11 D.P.827115 - APPROXIMATE LAND ACQUISITION 9757m²

/

/

/ /

/

/

120

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

/

/

/

/

/

/

/

/

/ /

/

/

140

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/ /

/

/ /

/

/ /

/

/

/

/

/ /

/

/

/

/

160

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-005

B

Mar 06, 2024 - 9:26am

/

D.P.882365 - APPROXIMATE LAND ACQUISITION 330m²


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 3

120

PROPOSED BOUNDARY / /

/

TC 127.23

/

/

/

/

EXISTING DP BOUNDARY

/

/ /

/

/

/

/

/

/ / /

/

/ /

/

/

/ / /

/

/

/

/

/

/

/

/

/ / /

/ /

EXISTING STORMWATER EASEMENT

/ /

/

/

/

/

140

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

/ /

/

EXISTING SEWER EASEMENT

/

/

/

/

/

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

160

/ /

PROPOSED PROPERTY ACQUISITION

/ /

/

/

/

/

/ / /

/ /

/ /

/ /

/

/

/ /

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

180

/

/ /

/ /

/ /

/

/ /

/

/

/

/ / /

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

53

/

/

/

/

0 201. 0 2 T C

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

60

/

8709.00

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ / /

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

0

/

/

/

E IV

/

ER B IN 60 E H 2

/ /

/

0.0

/

/

/

DR

/

S

/

/

AN

/

/

R GE

/

/

/

.73

9 24

CIR

/

/

/

2

IT U C

/

/

40

/

/

OH RN

KE

/

90. 08

/

/

2

20

/

LIZ

/

/

.59

/

/

40 C 40 T

/

.46 4 2

/

/

/

LOT 101, D.P.631430 - APPROXIMATE LAND ACQUISITION 6300m²

/

/

0

22

/

R

/ /

/ / /

/ / /

/ / /

/ / / / / /

0

/

28

/ /

/ / / /

/ / / / / /

/ / / /

/ / / /

2

/

0

.0 95

/

0

/

30

/ / /

/ / /

/ /

/

/

/

/

/

/

/ /

/

/ / /

/ /

/

/ /

/ /

/

/

/ / /

/ /

/

/

/ / /

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

.60 2 0 32 C 32 T

/

/

/ /

/

/

/ / / / / / / / / / /

/ / / / / /

/ / / / / / / / / / / /

/

/ / /

/ / / /

/

/ / / / / / / / / /

/

/ / / / / / / / /

LOT 301, D.P.1143646 - APPROXIMATE LAND ACQUISITION 2481m²

/ / /

/

0

/ /

34

/ / / / /

/ / / / / /

/ / / / / / /

/ / / / /

/ / / / / / /

/ / / / / / / /

/ / / /

/ / / / /

ET

/ /

/ / / /

/ / / /

/

S 360 DJOIN A

/ /

/

E SH

7

/ / / / /

/ / / /

/ /

/ / / / / /

/ / / /

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-006

B

Mar 06, 2024 - 9:26am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

/

380


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

57.75 40 41.00 CT 45.42

PROPOSED BOUNDARY EXISTING DP BOUNDARY EXISTING STORMWATER EASEMENT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

ADJOINS SHEET 8

/

/

/

/

/

/

/

/

/

GRIMES AVENUE

/

EXISTING SEWER EASEMENT

58

C2 6.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

.07

/

CT

/

/

/

/

0

/

/

/

/

/

/

/

0.0

480

54 8

.73

540

/

498 TC 500

20

520

527.72

T PROPOSED PROPERTY ACQUISITION

/

56 0

/

/

/

/

/

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

58 0

/ / / / / / / / / / / / / /

EIN RH

420 .36 3 2 4 CT

/

/

/

/

440

/

/ / / / / / /

/ / / / / / / /

4.0 0

62 0

/ / / /

62

/ /

/

/

/

/

/

/

64

/

0

/

/

/

/

/

/

/

/

/

/

38

/

/

IT

CU 0

R

/

CIR

/

0 40

S ER

N

E

60 0

/

/

/

RG BE

E K Z LI

HA O N

IV R D

/

/

/

/

/

/

36 0

/

66

/

0

/

/

/

JO AD

720

700

679.

680 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

T6 EE SH

64

/

/

/

/

S IN

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/ /

/ /

/ / /

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6 ET

E SH

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-007

B

Mar 06, 2024 - 9:26am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


ADJOINS SHEET 9

ADJOINS SHEET 7

LEGEND PROPOSED BOUNDARY EXISTING DP BOUNDARY EXISTING STORMWATER EASEMENT EXISTING SEWER EASEMENT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1040

1020

1000

980 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

960

940

920

900 900.58

879.00 880

870.98

860

840

/ / / / /

/

800

780

760 /

/

740

720 /

820

PROPOSED PROPERTY ACQUISITION

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

LIZ KERNOHAN DRIVE

/

/ / / /

/

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-008

B

Mar 06, 2024 - 9:26am

ADJOINS SHEET 9

ADJOINS SHEET 7

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


ADJOINS SHEET 8

LEGEND PROPOSED BOUNDARY EXISTING DP BOUNDARY EXISTING STORMWATER EASEMENT EXISTING SEWER EASEMENT

1184.83

1180

/

/

/

/

/

/

/

/

1160

/

/

/

/

/

/

/

1140 1144.00 CT 1145.93

/

/

/

CT 1 TC 1 112.23 113.9 9 1120

1100

TC 1091.21

1080

/

/

/

/

/

1040

/

1060

/

/

/

/

/

/

/

PROPOSED PROPERTY ACQUISITION

/

/

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

LAND ACQUISTION PLAN SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C107-009

B

Mar 06, 2024 - 9:26am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C107-00.dwg

LIZ KERNOHAN DRIVE


ADJOINS SHEET 2

LEGEND A-1

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT EXISTING STORMWATER LINE

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED

d50 500mm DUMPED ROCK 4m LONG 9.5m WIDE 840mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND EXTEND EXISTING TRIPLE CELL RCBC 2 UNIT LENGTHS

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20

0.00

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ /

/

/

80 /

/

40

/

/

/

TC 84.03

/

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

200 /

183.84 CTP 183.87

/

180

/

170.08

/

160

/

140

/

120

/

/

/

/

/

/

/

Ø375

/

75

Ø3

/

/

/

/

/

2-2

Ø375

2-3

5 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEY WAY

/

/

/

/

/

Ø37

C1-4

CAMDEN VA L

/

2-4

/

/

FOR PIPE PENETRATION REFER DETAIL ON C108-307

1-3

2-1 Ø375

Ø375 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1-2 MCB1 d50 500mm DUMPED ROCK 4m LONG 9.5m WIDE 840mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

1-1

C1-1 EXTEND EXISTING TRIPLE CELL RCBC 2.5 UNIT LENGTHS

A

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-001

B

Mar 06, 2024 - 9:27am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

C108-301


ADJOINS SHEET 3

ADJOINS SHEET 1

LEGEND A-1

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT EXISTING STORMWATER LINE

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED

d50 500mm DUMPED ROCK 4m LONG 15m WIDE 840mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND FOR PIPE PENETRATION REFER DETAIL ON C108-307

MCB1

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

360 CT 360.02

TC 344.60

340

320

380

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

297.63 300

400

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

Ø4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

289.31

420

/

/

/

/

/

/

/

/

/

/

/

280

440

/

/

/

/

/

/

/

/

/

/

/

/

/

260

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

240

480

/

236.26

500 /

50

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220 220.07 CT

6-2 75

/

4-7

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6-1 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

Ø375

Ø450

4-6

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100 102.83

Ø450

/

0 Ø45

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

5-1 /

/

/

/

/

/

/

/

/

/

/

200

MCB1

/

4-8 /

183.84 CTP 183.87

C2-4

Ø3

/

/

/

/

/

/

/

180

EXTEND EXISTING RCBC's 4 UNIT LENGTHS

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

4-5

4-4 7 Ø3

5

C2-1

4-3 CUSTOM LENGTH PRECAST UNIT TO SUIT EXISTING RCBC ADJACENT. LENGTH TO BE CONFIRMED ON SITE PRIOR TO PROCUREMENT.

CUSTOM LENGTH PRECAST UNIT TO SUIT EXISTING RCBC ADJACENT. LENGTH TO BE CONFIRMED ON SITE PRIOR TO PROCUREMENT.

A

EXTEND EXISTING RCBC's 2 UNIT LENGTHS

CONSTRUCT NEW ROADSIDE DRAIN

80

CT 71.44 Ø45 0

C108-302

d50 500mm DUMPED ROCK 4m LONG 15m WIDE 840mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

/

/

/

/

/

/

60 /

/

/

/

4-2

50 Ø4

/

/

/

/

/

/

REGRADE SURROUNDING AREA TO DIRECT FLOW TOWARDS HEADWALL. TO BE DESIGNED BY CARDNO STANTEC

/

/

/

/

4-1

/

/

/

/

/

/

/

/

/

/

/

/

TC 35. 97 40

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

/ / /

/ / / / /

/

/ / / / / /

/ / / / / /

/ / /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-002

B

Mar 06, 2024 - 9:27am

/ / /

/ / /

ADJOINS SHEET 3

0.00

/

/

/

/

/

/

/

/

/

/

/

/

HILDE

/

/

/

/

/

/

/

/

/

/

R STR

20 ADJOINS SHEET 1

OXLEY RIVULET UPGRADE DESIGNED BY CARDNO STANTEC

/

EET

/

/

/

/

/

/

/

/

/

MC03


/

/

/

/ /

/

/

LEGEND

/

/

/ /

/ /

/

/

/

/

/

/

/ /

/

/

ADJOINS SHEET 5

/

ADJOINS SHEET 5

/

/

/

160

/

/ /

/

/

/

/

/

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

180

A-1

/

/

/

/

/

/

/

EXISTING STORMWATER LINE

/

/

/

/

/

/

/

/

/

HERBERT RIVULET DESIGN BY CARDNO STANTEC

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

KIRKHAM LANE

/

/

/

/

/

/

/

/

/

/

220

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

d50 200mm DUMPED ROCK 1.2m LONG 1.5m WIDE 400mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

/

/

d50 500mm DUMPED ROCK 4m LONG 15m WIDE 840mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

240

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

800

780

760

Ø375 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 269.56

278.06 0.00 TC 0.05

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

Ø375

/

/

/

/

/

/

/

/

/

/

/

/

/

/

Ø375 /

/

/

8-3 /

/

740

/ / /

/

/

/

8-2

/

7-2

Ø375

MCB1

/

/ /

/ / / / / / /

/

C3-4

/

75 Ø3

/

/

/

/

7-1

75

7-3

255.48 257.25 260

720

/ / /

/

/

/

/

/

/

/

/

/

/

640

/

/

/

/

/

/

660

/

/

/

8-4

700

/ /

/

/

Ø375

620 621.54 623.99

600

580

520

540

560 TC 563.58

/

/

667.41

/

/

/

/

8-5

Ø3

500

FOR PIPE PENETRATION REFER DETAIL ON C108-306

680

/

/

/

/

/

/

EXTEND EXISTING RCBC's 4 UNIT LENGTHS

671.96 CT 674.84

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

9-4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

9-5

Ø375

/

/

/

/

Ø375 /

/

/

/

/

/

/

/

CAMDEN VALLEY WAY

CUSTOM LENGTH PRECAST UNIT TO SUIT EXISTING RCBC ADJACENT. LENGTH TO BE CONFIRMED ON SITE PRIOR TO PROCUREMENT.

/

/

9-6

20

C3-1 10-3 Ø37

5

Ø375

MERGE BATTER TO HEADWALL

A

EXTEND EXISTING RCBC's 3 UNIT LENGTHS

10-2

10-1

C108-303

d50 500mm DUMPED ROCK 4m LONG 15m WIDE 840mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

23-2

23-1

d50 300mm DUMPED ROCK 1.6m LONG 2.2m WIDE 600mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

CT 59.76 60

Ø375

12-1

120

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 1cm at full size

TC 127.23

/

10

/

5

/

0

Ø600

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

ADJOINS SHEET 6 /

ADJOINS SHEET 6

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

100

DIVERSION CHANNEL 1 CONSTRUCT A DIVERSION DRAIN 1.0m WIDE TO DIRECT FLOWS TO PIPE INLET. REFER TO C101-103 FOR DETIALS

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-003

B

Mar 06, 2024 - 9:27am

ADJOINS SHEET 2

Ø600

11-6

80

ADJOINS SHEET 4

00

LIZ KERNOHAN DRIVE

Ø6

11-7

0

BREAK IN MEDIAN FOR MAJOR FLOWS TO TfNSW R0220-47

MCA1

11-8

d50 200mm DUMPED ROCK 2.3m LONG 1.9m WIDE 400mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

-1

DIVERSION CHANNEL 2 CONSTRUCT A DIVERSION DRAIN 1.0m WIDE TO DIRECT FLOWS TO PIPE INLET. REFER TO C101-103 FOR DETIALS

(2x)Ø525

d50 200mm DUMPED ROCK 1.2m LONG 1.5m WIDE 400mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

Issue

40.00


ADJOINS SHEET 3

LEGEND A-1

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT EXISTING STORMWATER LINE

8-1 //

//

//

//

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / /

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

/

/

/

/

ADJOINS SHEET 3

/

/

/

/

/

/

/

/

/ / /

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-004

B

Mar 06, 2024 - 9:27am

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

9-1

9-3 /

/

375

Ø375

/

/

/

/

/

/

/

/

/

/

/

/

/

/

EN VALLEY WAY CAMD Ø

9-2

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

945.79

MCB1

940

920

900

880

860

840

820

800

TC 864.55

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED


LEGEND A-1

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT EXISTING STORMWATER LINE

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED

0.00 / /

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

20

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

40

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/ /

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / / / / / /

/ / / / / / / /

/ /

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

KIRKHAM LANE

/

/ /

/ / / / / / / / / /

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/ /

80

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

120

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/ /

/

/ /

/

/ /

/

/

/

/

/ /

/

/

/

/

160

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-005

B

Mar 06, 2024 - 9:27am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

/

140


Ø375

LEGEND 12-1

ADJOINS SHEET 3

ADJOINS SHEET 3

120

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT

/

Ø600

/

A-1

/

TC 127.23

/

/

/

/ /

/ /

/

/

/

/

/

/ / /

/

/ /

/

/

/ / /

/

/

/

/

/

/

/

/

/ / /

/ /

/ /

/

/

/

/

140

/ /

/

/

/ /

/ /

/ /

/ /

HERBERT RIVULET DESIGN BY CARDNO

/ /

/ /

/ /

/ /

EXISTING STORMWATER LINE

/

/

/

/

11-5

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED

/

160

/ /

/ /

/

/

/

/

/ / /

/ /

/ /

/ /

/

/

/ /

/ /

/

Ø60

/

/ /

/

/

/ /

/

0

/

/ /

/ /

/

180

/

/ /

/ /

/ /

/

/ /

/

/

/

/ /

13-1

/

/ /

/

/

/ /

/

/

/

Ø450

/

/ /

/ /

/ /

/

53

/

/

/

/

0 201. 0 2 T C

/

/ /

/

/

/

11-4

/

/

/

/

/

/

/

/

/

/ /

/ /

/

MCA1

/

/

/

/

/

/

/

/

5 Ø4

/

/

/

/ /

/

/

/

/

/

/

/

/

0

/

/

/

/

/

/

/

/

/

/

60

/

8709.00

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ / /

/ / / / / /

/ /

/

/

/

/ / /

/

/

/

14-1

/

/

/

AN

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

MC01

/

/

25 Ø5

/

75 Ø3

/

Ø5

/ /

60

/ / / /

2

/

/

E IV

/

14-3

25

/

/

DR

/

0

/

/

/

/

3

0.0

Ø4 50

/

/

OH RN

50

Ø4

RG

E .7 RH249 15-1

90. 08

/

/

KE

/

/

E B N I

/

/

/

2

/

/

/

40

/

/

/

CIR

S ER

14-2

/

/

2

20

/

LIZ

/

/

.59

/

/

/

IT U C

40 C 40 T

/

.46 4 2

/

/

/

11-3

/

/

0

22

/

14-4

/ /

/ / /

/

Ø525

/ /

/ / / / / /

0

28

/ /

/

14-5

/

11-2

/ / /

/ / / / / /

Ø3

/ / / /

/ / / /

2

/

75

0

.0 95

/

0

/ / / /

/

25 Ø5

30

/ /

/ /

11-1

/

/

/

/

/

/

/ /

/

/ / /

/ /

/

/ /

/ /

/

/

/ / /

/ /

/

/

/ / /

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

.60 2 0 32 C 32 T

/

/

/ /

/

/

/ / / / / / / / / / /

/ / / / / /

/ / / / / / / / /

14-6

/ / /

/

/ / /

/ / / /

/

/ / / / / / / / / /

/

/ / / / / / / / / / / /

/

0

/ /

34

/ / / / /

/ / / / / /

/ / / / / / /

/ / / / /

/ / / / / / /

/ / / / / / / /

/ / / /

/ / / / /

ET

/ /

/ / / /

/ / / /

/

S 360 DJOIN A

/ /

/

E SH

7

/ / / / /

/ / / /

/ /

/ / / / / /

/ /

/

Ø3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

/

75

380

22-2

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-006

B

Mar 06, 2024 - 9:27am

/

22-1


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

ADJOINS SHEET 8

/

/

/

/

/

/

/

/

/

GRIMES AVENUE

/

57.75 40 41.00 CT 45.42

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MC02

A-1

EXISTING STORMWATER LINE

18-3

58

C2 6.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

540

/

75

Ø3

18-2 CT

/

/

0

/

/

/

/

/

/

/

/

/

C4-1

0.0

480

54 8

.73

520

.07

Ø37 5

/

498 TC 500

/

20 18-1

/

527.72

T NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED

/

/

/

d50 400mm DUMPED ROCK 10m LONG 23m WIDE 750mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

56 0

/ /

/

460

/

/

/

/

/

/

/

/

/

/

00

15 /

/

/

/

0x

0 )21 (4x /

/

/

/

58 0

/ / / / / / / /

/

/

/

/

/

C4-2

/

EIN RH

420 .36 3 2 4 CT

/

/

/

/

440

/

/ /

60 0

/ / / / / / / /

/ / / / / / /

/

/

/

A

/

C108-304

62

/

4.0 0

/

62 0

R

/

/

/

/

/

/

/

64

/

0

/

/

/

/

/

/

/

/

/

/

38

/

/

IT

CU 0

N

E

/

CIR

E K Z LI

HA O N

IV R D

/

0 40

S ER

RG BE

MCA1

/

/

/

/

36 0

/

0

/

66

/ /

JO AD

/

/

/

d50 400mm DUMPED ROCK 10m LONG 23m WIDE 750mm THICK WITH BIDIM A34 KEYED 300mm ALL AROUND

22-2

720

700

679.

680 /

/

/

/

/

Ø3 7

/

5

/

/

/

/

/

T6 EE SH

64

/

/

/

/

S IN

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

22-1

/

/

/

/

/

MCA1 /

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/ /

/ /

/ / /

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

KNIGHT STREET

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6 ET

E SH

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-007

B

Mar 06, 2024 - 9:28am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


ADJOINS SHEET 9

ADJOINS SHEET 7

LEGEND A-1

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT EXISTING STORMWATER LINE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20-1

21-1

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

LIZ KERNOHAN DRIVE

/

/ / / /

/ /

EXPOSE EXISTING PIPE, REMOVE END CAP, CLEAN OUT AND CONNECT

ADJOINS SHEET 9

ADJOINS SHEET 7

EXPOSE EXISTING PIPE, REMOVE END CAP, CLEAN OUT AND CONNECT

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

1040

1020

1000

980 /

/

/

/

/

960

940

920

900 900.58

879.00 880

870.98

860

840

/ / / / /

/

800

780

/

/

Ø375

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

/

/

/

/

/

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-008

B

Mar 06, 2024 - 9:28am

/

MCA1 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

Ø375

/

760

740

720 /

820

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED


ADJOINS SHEET 8

LEGEND A-1

PROPOSED STORMWATER PIT

Ø225

PROPOSED STORMWATER LINE

A-1

EXISTING STORMWATER PIT EXISTING STORMWATER LINE

1184.83

1180

/

/

/

/

/

/

/

/

/

1160

/

/

/

/

/

/

/

1140 1144.00 CT 1145.93

/

/

/

CT 1 TC 1 112.23 113.9 9 1120

1100

1080

MCA1

/ /

/

1060

/

1040

/

EXPOSE EXISTING PIPE, REMOVE END CAP, CLEAN OUT AND CONNECT

TC 1091.21

/

/

/

/

/

/

/

NOTE: REFER EXISTING UTILITIES PLAN FOR STORMWATER TO BE REMOVED

/

/

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

19-1

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT PLAN SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-009

B

Mar 06, 2024 - 9:28am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-00.dwg

Ø375

LIZ KERNOHAN DRIVE


2-3

2-2

2-4

4-1

4-3

4-2

IL 65.36

IL 65.77

2-1

C

IL 65.22 IL 63.89IL 64.89

W

IL 63.98

W

1.01

1.76

0.27

1.31

1.28

1.32

1.49

0

0.05

0.07

0.15

0.02

0.11

0.12

0.13

0.14

0.62

2.31

1.22

0.61

1.00

1.01

0.51

1.26

0.75

1.00

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø450 RCP-2

Ø450 RCP-2

Ø450 RCP-2

Ø450 RCP-2

Ø450 RCP-2

46.85

13.37

4.56

4.70

44.75

4.11

17.69

27.58

10.36

21.99

41.22

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-10.dwg

65.06 118.96

65.35

64.32 1.43

65.24 77.74

65.85

63.92

64.67 64.60 1.51 1.51

65.07 55.75

66.03

64.34 64.34

64.83 64.77 1.53 1.53

65.44 45.40

66.08

64.50 64.50

64.94 64.89 1.45 1.45 64.63 64.63

66.18 65.60

65.08 65.08 52.80

66.17 64.73 48.69

17.45

64.58 64.58

64.72 64.64

1.69 1.71 0.77 0.77 0.75

65.25 3.94

65.67

64.38 64.35 64.31 64.31 64.33

64.92 64.88 0.83 0.83 64.65 64.65

64.92 0.99 64.70 65.70 65.35

LINE 2

LINE 4

A1 HORIZONTAL SCALE 1 : 500 A1 VERTICAL SCALE 1 : 100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER LONGITUDINAL SECTIONS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-101

B

Mar 06, 2024 - 9:28am

LINE 1

48.00

0.00

64.64 64.73 65.03

66.17

1.71 1.71

65.29

66.05

64.36 64.35

64.77 1.56 1.56 1.55 64.44 64.44 64.45

65.99

1.41 1.46 64.58 64.53

64.82 64.79

0.89 64.80

60.91

CHAINAGE

65.80

EXISTING SURFACE LEVEL

46.79

DESIGN SURFACE LEVEL

65.70

INVERT LEVEL

65.42

DEPTH TO INVERT FROM DESIGN SURFACE

0.00

HYDRAULIC GRADE LINE

49.00

64.98

49.00

65.15 65.00

LENGTH (m)

1.41 1.41

PIPE SIZE (mm) PIPE CLASS

64.77 64.77

0.47

65.17

PIPE GRADE (%)

1.19

0.06

64.95

0.06

66.14

PIPE FLOW (m3/s)

DATUM R.L.

0.72

65.88

0.76

C

0.00

1.07

4-6

W

W

VELOCITY (m/s)

4-5

4-4

IL 64.87

2-3

IL 65.09

1-3

1-2

LINE 1

LINE 2 1-1


6-1

6-1

6-2

7-1

7-3

7-2

8-1

8-2

IL 62.76

5-1

LINE 5

4-8

4-7

LINE 6 4-6

VELOCITY (m/s)

1.50

1.92

1.15

2.13

1.04

1.33

0.63

PIPE FLOW (m3/s)

0.16

0.19

0.06

0.1

0.06

0.09

0.04

PIPE GRADE (%)

1.01

0.99

1.00

2.03

0.52

0.52

4.91

PIPE SIZE (mm) PIPE CLASS

Ø450 RCP-2

Ø450 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

LENGTH (m)

14.03

10.58

14.00

10.26

33.01

12.91

69.31

68.89 69.83

1.13 68.70

72.29 1.14 72.10

69.43 69.31

73.24 74.18

64.42 64.32 45.42

LINE 7

0.00

64.12 64.12 0.52 0.52

64.64 33.01

65.31

63.90 63.90

64.25 64.19 1.36 1.36 63.97 63.97

64.33 0.88 64.14 65.01 64.73

64.40 12.14

LINE 6

54.00

0.00

65.04

64.40

0.77 0.77 63.62 63.62

63.79 63.79

1.21 63.87

64.11

LINE 5

LINE 4

48.00

0.00

65.08 65.04 14.00

65.08

64.18 64.11 1.16 1.21 63.92 63.87

64.24 1.02 64.06 64.98 0.00

64.33 64.43 143.56

48.00

65.08

63.95 63.95 0.65 0.65

65.34

63.68 63.68

64.15 64.09 1.56 1.56 63.78 63.78 65.09

CHAINAGE

132.99

EXISTING SURFACE LEVEL

65.35

DESIGN SURFACE LEVEL

65.06

INVERT LEVEL

118.96

DEPTH TO INVERT FROM DESIGN SURFACE

48.00

1.43 1.43

HYDRAULIC GRADE LINE

64.32 64.21

48.00

63.92 63.92

DATUM R.L.

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-10.dwg

W

LINE 8

A1 HORIZONTAL SCALE 1 : 500 A1 VERTICAL SCALE 1 : 100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER LONGITUDINAL SECTIONS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-102

B

Mar 06, 2024 - 9:28am

IL 62.40

W


8-3

8-4

8-5

9-1

9-2

9-3

9-4

W

IL 61.33

IL 71.86

8-2

W

VELOCITY (m/s)

1.13

1.26

1.91

1.27

1.39

1.82

PIPE FLOW (m3/s)

0.06

0.07

0.09

0.08

0.1

0.18

PIPE GRADE (%)

5.20

1.47

1.66

3.25

4.70

5.27

PIPE SIZE (mm) PIPE CLASS

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

LENGTH (m)

71.09

20.37

30.18

6.64

46.05

72.54

68.93

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-10.dwg

70.05 125.24

LINE 9

A1 HORIZONTAL SCALE 1 : 500 A1 VERTICAL SCALE 1 : 100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER LONGITUDINAL SECTIONS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-103

B

Mar 06, 2024 - 9:28am

73.68 52.69

73.56

69.93

1.33 68.60

72.75 72.73 1.14 1.14

76.04 6.64

75.67

72.42 72.42

74.84 74.81 1.09 1.09 74.58 74.58

75.00 1.15 74.80 75.95 76.31

64.66 63.71 190.95

LINE 8

0.00

64.36 64.36 0.46 0.46

64.86 160.77

66.03

64.20 64.20

64.95 64.92 1.33 1.33

66.64

64.70 64.70

65.25 65.20 1.64 1.64 65.00 65.00 65.71

CHAINAGE

140.40

EXISTING SURFACE LEVEL

69.83

DESIGN SURFACE LEVEL

69.43

INVERT LEVEL

69.31

DEPTH TO INVERT FROM DESIGN SURFACE

1.13 1.13

HYDRAULIC GRADE LINE

55.00

68.89 68.87

49.00

68.70 68.70

DATUM R.L.


9-5

9-6

10-1

10-2

10-3

11-1

11-3

11-2

C

VELOCITY (m/s)

1.83

2.41

1.04

1.38

0.64

1.76

PIPE FLOW (m3/s)

0.24

0.36

0.06

0.1

0.03

0.03

PIPE GRADE (%)

4.10

1.42

0.50

0.48

2.34

2.29

PIPE SIZE (mm) PIPE CLASS

Ø450 RCP-2

Ø450 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

LENGTH (m)

80.55

45.72

19.00

20.62

21.32

26.26

70.98

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-10.dwg

67.66 47.58

72.30

1.40

68.44 21.32

72.99

70.90

71.64 71.64 1.49 1.49 71.50 71.50

72.14 1.37 72.00 73.37 68.50

65.33 65.10 40.82

LINE 10

0.00

64.78 64.78 0.78 0.78

66.31 19.00

65.83

64.55 64.55

64.95 64.90 1.12 1.17 64.70 64.66

65.00 1.18 64.80 65.98 66.51

65.93 65.93 251.50

LINE 9

54.00

0.00

64.96 64.96 1.38 1.38

66.37

64.55 64.55

66.15 65.71 1.12 1.17 65.25 65.20 66.47

CHAINAGE

205.79

EXISTING SURFACE LEVEL

69.93

DESIGN SURFACE LEVEL

70.05

INVERT LEVEL

125.24

DEPTH TO INVERT FROM DESIGN SURFACE

1.33 1.38

HYDRAULIC GRADE LINE

49.00

68.93 68.89

51.00

68.60 68.55

DATUM R.L.

LINE 11

A1 HORIZONTAL SCALE 1 : 500 A1 VERTICAL SCALE 1 : 100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER LONGITUDINAL SECTIONS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-104

B

Mar 06, 2024 - 9:28am

IL 65.32

9-4


11-5

11-6

11-8

11-7

11-6

12-1

LINE 11 13-1

11-4

14-1

14-2

IL 72.93 72.94 IL 72.46

11-4

LINE 11

LINE 12

LINE 13 11-3

G C

VELOCITY (m/s)

1.79

1.42

1.35

1.33

1.74

0.67

1.44

1.40

PIPE FLOW (m3/s)

0.04

0.14

0.14

0.19

0.2

0.03

0.06

0.22

PIPE GRADE (%)

3.03

3.35

3.60

3.66

0.77

1.02

1.01

1.47

PIPE SIZE (mm) PIPE CLASS

Ø750 RCP-2

Ø750 RCP-2

Ø750 RCP-2

Ø750 RCP-2

Ø750 RCP-2

Ø375 RCP-2

Ø450 RCP-2

Ø450 RCP-2

LENGTH (m)

53.78

35.14

41.73

26.17

23.04

19.10

16.40

18.76

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-10.dwg

LINE 14

A1 HORIZONTAL SCALE 1 : 500 A1 VERTICAL SCALE 1 : 100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER LONGITUDINAL SECTIONS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-105

B

Mar 06, 2024 - 9:28am

73.39 18.77

73.38

72.52 1.48 71.90

72.63 1.18 72.18 73.36 73.36

70.42 66.71 16.40

LINE 13

0.00

69.22 69.06 1.34 1.56 69.08 68.85

69.46 1.31 69.24 70.55 67.03

67.65 66.60 19.10

LINE 12

56.00

0.00

66.42 66.42 1.47 1.49 66.17 66.16

66.54 1.67 66.37 68.04 66.76

66.24 66.25 227.44

LINE 11

53.00

0.00

65.23 65.23 1.24 1.24

66.55 204.40

66.66

65.00 65.00

65.47 65.47 1.46 1.48

66.60 178.23

67.65

65.20 65.18

66.42 66.42 1.47 1.49 66.17 66.16

66.64 136.50

70.42

69.18

1.50 1.50 67.68 67.68

67.89 67.89

1.55 1.56 68.87 68.85

70.98 70.58

66.71

CHAINAGE

101.36

EXISTING SURFACE LEVEL

72.30

DESIGN SURFACE LEVEL

67.66

INVERT LEVEL

47.58

DEPTH TO INVERT FROM DESIGN SURFACE

1.40 1.80

HYDRAULIC GRADE LINE

51.00 69.06 69.06

52.00

70.90 70.50

DATUM R.L.


LINE 14 15-1

14-4

18-1

18-2

18-3

19-1

19-2

19-3

20-1

20-2

20-3

1.30

1.95

2.32

0.79

0.54

0.76

1.34

PIPE FLOW (m3/s)

0.25

0.26

0.41

0.42

0.1

0.03

0.04

0.03

0

0.03

0

PIPE GRADE (%)

1.04

2.22

1.15

1.08

1.00

0.99

1.15

1.24

47006.19

1.32

21349.13

PIPE SIZE (mm) PIPE CLASS

Ø450 RCP-2

Ø525 RCP-2

Ø525 RCP-2

Ø525 RCP-2

Ø525 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø225 RCP-2

Ø375 RCP-2

LENGTH (m)

23.51

20.52

15.42

40.98

7.00

7.00

19.89

8.63

7.25

8.46

7.54

55.00

56.00

LINE 15

LINE 14

1.28 1.28

85.18

85.18

15.96

15.96

85.66

83.90 83.90

84.03 1.76 1.76 1.66 83.90 83.90 84.00

84.26 1.12 84.11 85.41

85.23

LINE 19

0.00

89.69 16.66

89.69

1.39 1.39

89.69 16.66

90.09

88.30 88.30

88.40 1.79 1.79 1.69 88.30 88.30 88.40

88.66 1.19 88.51 89.94 90.19

73.41 73.28 25.96

LINE 18

69.00

0.00

71.77 71.77 1.88 1.88 71.53 71.53

73.71 7.07

72.94

1.19 1.19 71.75 71.75

71.92 71.92

1.12 71.82 73.66

72.93

1.35

73.00

0.00

69.16 0.00

72.84

1.14 1.64 71.69 71.20

72.06 1.07 71.76 69.24 -7.00

73.78 73.89 119.07

72.84

70.99 70.99 3.20 3.20

68.93 78.44

73.41

70.58 70.58

71.55 71.45 2.38 2.38

69.16 62.79

72.84

71.02 71.02

72.04 71.69 1.64 1.64

73.14

71.20 71.20

72.13 72.12 1.49 1.49 71.66 71.66 70.18

CHAINAGE

42.27

EXISTING SURFACE LEVEL

73.38

DESIGN SURFACE LEVEL

73.39

INVERT LEVEL

18.77

DEPTH TO INVERT FROM DESIGN SURFACE

1.48 1.48

HYDRAULIC GRADE LINE

72.52 72.28

55.00

71.90 71.90

DATUM R.L.

72.00

1.78

72.04 71.69

VELOCITY (m/s)

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-10.dwg

14-6

LINE 20

A1 HORIZONTAL SCALE 1 : 500 A1 VERTICAL SCALE 1 : 100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER LONGITUDINAL SECTIONS SHEET 6 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-106

B

Mar 06, 2024 - 9:28am

14-5

14-4

85.18

LINE 15 14-3

14-2


23-1

23-2

C2A-1

C2A-2

C2A-3

C2A-4

C2B-1

C2B-2

W

IL 61.94

IL 61.95

W

W

W

0.01

0.62

0

0

0

0

0

0

0

0

0

1.29

15476.38

1.22

0.50

1.04

0.43

1.04

1.04

0.43

1.04

1.04

0.43

1.04

PIPE SIZE (mm) PIPE CLASS

Ø225 RCP-2

Ø375 RCP-2

Ø375 RCP-2

Ø(2x)525 RCP-2

Ø2700x900 RCBC

Ø2700x900 RCBC

Ø2700x900 RCBC

Ø1800x900 RCBC

Ø1800x900 RCBC

LENGTH (m)

8.58

7.19

23.29

46.82

4.80

14.07

9.60

14.07

9.60

RCBC

RCBC

4.80

14.07

9.60

4.80

47.00

47.00

0.90 0.90

0.90 0.90

63.66 63.66

63.56 63.56 64.56 23.67

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-10.dwg

64.52 14.07

LINE C2c

A1 HORIZONTAL SCALE 1 : 500 A1 VERTICAL SCALE 1 : 100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER LONGITUDINAL SECTIONS SHEET 7 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-107

B

Mar 06, 2024 - 9:28am

65.36 0.00

65.25

0.90 0.90 63.72 63.72 65.34

0.90 63.77 64.67 64.67

64.46 23.67

LINE C2b

-4.80

0.90 0.90 63.56 63.56

64.79 14.07

64.46

0.90 0.90 63.66 63.66

64.62 0.00

65.29

0.90 0.90 63.72 63.72 65.38

0.90 63.77 64.67 64.14

64.04 23.67

LINE C2a

-4.80

0.90 0.90 63.56 63.56

64.90 14.07

64.46

0.90 0.90 63.66 63.66

64.94 0.00

65.35

0.90 0.90 63.72 63.72 65.44

0.90 63.77 64.94 -4.80

65.48 46.98

64.67

(null)

(null) (null)

64.77 0.00 64.77

LINE 23

LINE 22

RCBC

Ø1800x900 RCBC

65.15 65.15

0.77 65.00 66.70 0.00

73.53 23.29

73.55

65.73

72.50 72.50 1.10 3.77 72.45 69.78

73.85

LINE 21

Ø(2x)3000x900Ø(2x)3000x900Ø(2x)3000x900

47.00

65.54

49.00

72.80 81.01

81.01

1.56 1.56 79.45 79.45

81.36

1.91 1.91 1.81 79.45 79.45 79.55

79.58

1.46

15.77

CHAINAGE

81.01

EXISTING SURFACE LEVEL

15.77

DESIGN SURFACE LEVEL

79.65

INVERT LEVEL

81.11

DEPTH TO INVERT FROM DESIGN SURFACE

81.27

HYDRAULIC GRADE LINE

56.00

79.80

64.00

0.00

DATUM R.L.

1.12

PIPE GRADE (%)

C2C-4

0

72.73

0.03

C2C-3

1.86

73.76

PIPE FLOW (m3/s)

C2C-2

0.92

0.00

1.34

C2C-1

W

W

VELOCITY (m/s)

C2B-4

IL 63.66

C2B-3

64.46

22-2

IL 61.93

22-1

IL 63.56

21-3

21-2

IL 63.77

21-1


PIT TYPE

GRATE SIZE

PIT STRUCTURE

See Camden Council Standard Drawings Drawing No. SD12 Rev A

2.4m Sag Lintel 1.8m Lintel 1.8m Sag Lintel 2.4m Sag Lintel Surface Inlet Surface Inlet 375Ø Headwall 1.8m Lintel 2.4m Lintel 2.4m Lintel 2.4m Lintel 1.8m Lintel 1.8m Lintel 1.8m Lintel 1.8m Lintel 450Ø Headwall 1.8m Sag Lintel 2.4m Sag Lintel 375Ø Headwall 2.4m Lintel 2.4m Sag Lintel 375Ø Headwall 2.4m Lintel 2.4m Lintel 2.4m Lintel 2.4m Lintel 375Ø Headwall Surface Inlet 1.2m Lintel 2.4m Lintel 2.4m Lintel 3.6m Lintel 375Ø Headwall 2.4m Sag Lintel 2.4m Sag Lintel 375Ø Headwall 1.8m Lintel 1.8m Lintel 1.8m Lintel

900x900 900x900 PRECAST HEADWALL

PRECAST HEADWALL

PRECAST HEADWALL

PRECAST HEADWALL

PRECAST HEADWALL 900x900

PRECAST HEADWALL

11-4 11-5 11-6 11-7 11-8 12-1 13-1 14-1 14-2 14-3 14-4 14-5 14-6 15-1 18-1 18-2 18-3 19-1 19-2 20-1 20-2 21-1 21-2 22-1 22-2 23-1 23-2 C1-1 C1-4 C2-1 C2-4 C3-1 C3-4 C4-1 C4-2

PIT TYPE 2.4m Lintel 1.8m Lintel 1.8m Lintel 2.4m Lintel 750Ø Headwall 1.8m Lintel 2.4m Lintel Direct Connection 1.8m Lintel 1.8m Lintel 3.0m Sag Lintel 3.0m Sag Lintel 1.8m Sag Lintel 3.6m Sag Lintel 2.4m Sag Lintel 2.4m Sag Lintel Direct Connection 2.4m Lintel Direct Connection 2.4m Lintel Direct Connection 2.4m Lintel Direct Connection 1.8m Lintel 1.8m Lintel Multipipe Headwall Multipipe Headwall Multipipe Headwall Multipipe Headwall Multipipe Headwall Multipipe Headwall Multipipe Headwall Multipipe Headwall Multipipe Headwall Multipipe Headwall

GRATE SIZE

REMARKS

PRECAST HEADWALL

See C108-003 for details See C108-003 for details See C180-301 for details See C180-301 for details See C180-302 for details See C180-302 for details See C180-303 for details See C180-303 for details See C180-304 for details See C180-304 for details

PRECAST HEADWALL

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-20.dwg

1-1 1-2 1-3 2-1 2-2 2-3 2-4 3-1 4-1 4-2 4-3 4-4 4-5 4-6 4-7 4-8 5-1 6-1 6-2 7-1 7-2 7-3 8-1 8-2 8-3 8-4 8-5 9-1 9-2 9-3 9-4 9-5 9-6 10-1 10-2 10-3 11-1 11-2 11-3

REMARKS

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER SETOUT AND SCHEDULES

Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-201

B

Mar 06, 2024 - 9:28am

PIT STRUCTURE


EXISTING BOUNDARY

MCB1

300

300

GRADE TO EXISTING SURFACE AT 1V:6H MAX

GRADE OUTLET TO MEET EXISTING CHANNEL DOWNSTREAM

3 x 2400mm x 750mm RCBC 2.5 UNITS IN LENGTH @ 1% GRADE

3 x 2400mm x 750mmRCBC 2.0 UNITS IN LENGTH @ 1% GRADE

EXISTING 3 x 2400mm x 750mm RCBC

IL64.43 Ex WATR

IL64.49

Ex WATR

ELEC

A

SCALE 1:50

C108-001

Ex SWR R

8630 NOM. (TO BE CONFIRMED ON SITE)

150

1470

SECTION

IL64.32

Ex SWR R

IL64.27

1470

℄

1 C108-306

135

° 135

15 0

1470

°

B CULVERT 1 HEADWALL PLAN SCALE 1:25

300 MIN. 300

300 MIN.

2400x750

2400x750

2400x750

750

2400x750

0

250

500

1000

1500

2000

2500mm

SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

5 metres

B

SCALE 1:25

-

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER CULVERT 1 DETAILS

Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-301

B

Mar 06, 2024 - 9:29am

SCALE 1:25 @ A1 SCALE 1:50 @ A3

SECTION

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

11780 NOM. (TO BE CONFIRMED ON SITE)


MCB1

EXISTING BOUNDARY

300

300

GRADE OUTLET TO MEET EXISTING CHANNEL DOWNSTREAM

GRADE TO EXISTING SURFACE AT 1V:6H MAX

PROPOSED 1 x 3000mm x 900mm RCBC EXISTING 2 x 3000mm x 900mm RCBC EXISTING 1 x 1800mm x 900mm RCBC PROPOSED 1 x 3000mm x 900mm RCBC

1 x 1800mm x 900mm RCBC 4 x 3000mm x 900mm RCBC 4.0 UNITS IN LENGTH @ 1% GRADE Ex WATR

1 x 1800mm x 900mm RCBC 4 x 3000mm x 900mm RCBC 4.0 UNITS IN LENGTH @ 1% GRADE

IL63.72 ELEC

IL63.77 COMM

SECTION

A

SCALE 1:50

C108-002

Ex SWR R

IL63.66 IL63.56 Ex SWR R Ex WATR

150

15750 NOM. (TO BE CONFIRMED ON SITE)

℄

1 C108-306

135

° 135

15 0

1470

°

B CULVERT 2 HEADWALL PLAN

300 MIN.

300 MIN.

300

SCALE 1:25

1800x900

3000x900

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

3000x900

18730 NOM. (TO BE CONFIRMED ON SITE)

SCALE 1:25 @ A1 SCALE 1:50 @ A3

0

250

500

1000

1500

2000

2500mm

SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

0.5

1

2

3

4

5 metres

SECTION

B

SCALE 1:25

-

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER CULVERT 2 DETAILS

Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-302

B

Mar 06, 2024 - 9:29am

3000x900

750

3000x900


EXISTING BOUNDARY

PROPOSED BOUNDARY

MCB1

GRADE OUTLET TO MEET EXISTING CHANNEL DOWNSTREAM

300

300

GRADE TO EXISTING SURFACE AT 1V:6H MAX

Ex WATR

Ex COMM

ELEC

IL64.06

3 x 3000mm x 900mm RCBC IL64.00 2 x 1500mm x 900mm RCBC 1 x LINK SLAB 2.0 UNITS IN LENGTH @ 1% GRADE

PROPOSED 1 x 3000mm x 900mm RCBC EXISTING 2 x 1500mm x 900mm RCBC EXISTING 1 x LINK SLAB EXISTING 2 x 1500mm x 900mm RCBC EXISTING 1 x 3000mm x 900mm RCBC PROPOSED 1 x 3000mm x 900mm RCBC

SECTION

B

SCALE 1:50

C108-003

3 x 3000mm x 900mm RCBC 2 x 1500mm x 900mm RCBC 1 x LINK SLAB 2.0 UNITS IN LENGTH @ 1% GRADE

IL63.92 Ex SWR R

IL63.83

Ex SWR R

Ex WATR

150

15630 NOM. (TO BE CONFIRMED ON SITE)

1470

℄

1 C108-306

1470

15 0

1

35°

B CULVERT 3 HEADWALL PLAN SCALE 1:25

300 MIN.

390

300 MIN.

LINK SLAB

3000x900

3000x900

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

1500x900

2400x1050 OPENING

18700 NOM. (TO BE CONFIRMED ON SITE)

SCALE 1:25 @ A1 SCALE 1:50 @ A3

0

SCALE 1:50 @ A1 SCALE 1:100 @ A3

0

250

0.5

500

1

1000

2

1500

2000

3

4

2500mm

SECTION

B

SCALE 1:25

-

5 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER CULVERT 3 DETAILS

Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-303

B

Mar 06, 2024 - 9:29am

1500x900

750

3000x900


EXISTING BOUNDARY

MCA1

300

300

GRADE TO EXISTING SURFACE AT 1V:6H MAX

GRADE OUTLET TO MEET EXISTING CHANNEL DOWNSTREAM

PROPOSED 4 x 2100mm x 1500mm RCBC

ELEC IL71.09

SECTION

A

SCALE 1:50

C108-007

IL70.47

9960 NOM. T.B.C ON SITE

1470

1 C108-306

150

℄

135

15

0

1470

°

B

CULVERT 4 HEADWALL PLAN SCALE 1:25

300 MIN.

1045

300 MIN.

300 MIN.

2100 x 1500 BOX CULVERT

2100 x 1500 BOX CULVERT

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

13111 NOM. T.B.C ON SITE SCALE 1:25 @ A1 SCALE 1:50 @ A3

0

250

500

1000

1500

2000

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

2500mm

10 metres

SECTION

B

SCALE 1:25

-

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER CULVERT 4 DETAILS

Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-304

B

Mar 06, 2024 - 9:29am

2100 x 1500 BOX CULVERT

600

2100 x 1500 BOX CULVERT


250 WIDE EDGE BEAM

CULVERT 2 SLAB JOINTING LAYOUT

EJ

SC

EJ

DJ

EJ

SC

EJ

DJ

EJ

SC SC

EJ

EJ EJ

DJ

EJ

SC

EJ

250 WIDE EDGE BEAM

SC

EJ

SC

EJ

EJ

SC

EJ

HEADWALL

EJ

SC SC

EJ EJ EJ EJ EJ

DJ DJ

DJ

DJ DJ DJ

DJ

EJ EJ

250 THICK N16-200 TOP AND BOTTOM

250 THICK N16-200 TOP AND BOTTOM

DJ

DJ

EJ EJ EJ

SC SC SC SC SC

EJ EJ EJ EJ

EJ

EJ EJ

EJ EJ

EJ

SC SC

DJ DJ

DJ

SC SC

250 THICK N16-200 TOP AND BOTTOM

DJ

EJ

SC SC

EJ

EJ EJ

EJ

EJ

HEADWALL

HEADWALL

SC

DJ

EJ

EJ

SC

EJ

SC SC

EJ

EJ EJ

SC

SC SC

DJ

EJ EJ

DJ

SC

DJ DJ

SC

SC

DJ

SC SC

EJ EJ EJ

SC

EJ

HEADWALL

EJ

SC

EJ

SC

250 WIDE EDGE BEAM

SC

250 WIDE EDGE BEAM

250 THICK N16-200 TOP AND BOTTOM

CULVERT 3 SLAB JOINTING LAYOUT SCALE 1:100

SCALE 1:100

SCALE 1:100

EJ

SC

EJ

SC

EJ

SC

SC

EJ

SC

HEADWALL

EJ

SC SC

EJ

SC

EJ EJ

EJ

SC SC

EJ EJ

EJ

SC SC SC

EJ EJ EJ

SC SC SC

EJ EJ

SC

EJ

EJ

SC

250 THICK N16-200 TOP AND BOTTOM

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

250 THICK N16-200 TOP AND BOTTOM

250 WIDE EDGE BEAM

250 THICK N16-200 TOP AND BOTTOM

CULVERT 4 SLAB JOINTING LAYOUT SCALE 1:100

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

CULVERT SLAB JOINTING LAYOUT

Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-305

B

Mar 06, 2024 - 9:29am

250 WIDE EDGE BEAM

CULVERT 1 SLAB JOINTING LAYOUT

SC

EJ

250 THICK N16-200 TO AND BOTTOM

250 WIDE EDGE BEAM

SC

EJ

HEADWALL

HEADWALL

EJ EJ

SC SC

DJ DJ

DJ

SC SC

DJ

EJ EJ

HEADWALL

EJ

EJ

SC

DJ

EJ

SC

DJ

EJ

250 WIDE EDGE BEAM

EJ

250 WIDE EDGE BEAM


FILLER

DETAIL

1

SCALE 1:20

-

DEPRESS FABRIC MESH (CUT EVERY SECOND BAR) UNDER SAW CUT (TOP FABRIC IF TWO LAYERS)

T\2

350

250

T

SEALANT TYPE 'A'

SEALANT TYPE 'B'

T

PRECAST CULVERT WALL

SEALANT TYPE 'A'

N12 AT CORNERS 600 LAP WITH WALL REINFORCEMENT.

30mm REBATE IN BASE SLAB FOR RCBC's (TYP.) DOWEL CAP WITH EXPANSION SPACE

10 GAP 75 TYP.

N16-300 GALVANISED DOWELS 600mm LONG CENTRALLY PLACED

TYPICAL SAW CUT JOINT (SC) DETAIL

25

GALV. DOWELS. REFER DOWEL TABLE

BOND BREAKER

BOND BREAKER

25 300

DOWEL CAP WITH EXPANSION SPACE

TYPICAL EXPANSION JOINT (EJ) DETAIL

300

N.T.S

N.T.S

TYPICAL HEADWALL CORNER DETAIL

TYPICAL BASE SLAB DOWEL JOINT DETAIL

POLYURETHANE GUN GRADE SEALANT (SIKAFLEX PRO WITH PRIMER SP2 OR APPROVED EQUIVALENT INSTALLED TO MANUFACTURER'S INSTRUCTIONS)

CONCRETE PAVEMENT

F.S.L

5

2

T

POLYURETHANE GUN GRADE SEALANT (SIKAFLEX PRO WITH PRIMER SP2 OR APPROVED EQUIVALENT INSTALLED TO MANUFACTURER'S INSTRUCTIONS)

T + 50

SCALE 1:20

10

15

15

4

1/N16 OR 2/N12 TRIMMERS

100

D/4 (D = DEPTH OF SLAB)

BACKING ROD

150

600

SUB-BASE

TYPICAL EDGE BEAM (EB) DETAIL

BACKING ROD

INITIAL SAWCUT TO BE CUT WITHIN 24 HOURS OF POURING SLAB

20mm THICK EXPANDING CORK FILLER BOARD

N.T.S

3

6

TYPICAL JOINT SEALANT TYPE 'A' DETAIL

TYPICAL JOINT SEALANT TYPE 'B' DETAIL

SCALE 1:2

SCALE 1:2

'D

'

'X'

1/N16 OR 2/N12 TRIMMERS ALL AROUND 'D' + 600 LONG CRANK AS REQUIRED

TYPICAL HEADWALL PIPE PENETRATION DETAIL N.T.S DETAIL ONLY REQUIRED WHERE DIMENSION 'X' EXCEEDS 300mm

REFER TYPICAL HEADWALL BEAM DETAIL 1470

BOX CULVERT

300 MIN

PRECAST CONCRETE BOX CULVERT

550

N12 - 200 STARTER BAR LAP 500

N12-200 STARTERS LAP 500 WITH WALL REINFORCEMENT

TO SUIT CULVERT

N12 - 200 HORIZ. COG 200 INTO WALL

N12 - 200 VERT.

150

N12 AT CORNERS 600 LAP WITH WALL REINFORCEMENT.

300 MIN

N12-200 VERTICAL WALL REINFORCEMENT

SUBGRADE REPLACEMENT UNDER CULVERTS AND HEADWALLS TO ACHIEVE A MIN. BEARING CAPACITY OF 150kPa

0

1

2

4

SECTION

6

8

SCALE 1:20

B C02-101

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

TYPICAL HEADWALL BEAM DETAIL

N12-200 LONGITUDINAL IN KEY

N.T.S

SCALE 1:100 @ A1 SCALE 1:200 @ A3

250

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

EXPANSION JOINT, REFER TO DETAIL

N12-200 TOP AND BOTTOM EACH WAY N12-400 L-BARS 450 TOP LEG

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

CULVERT SLAB JOINTING DETAILS

Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-306

B

Mar 06, 2024 - 9:29am

CULVERT BASE SLAB REFER TO TYPICAL CULVERT BASE SLAB DETAIL

750

250

CJ


MAX WATER LEVEL 250mm 1

1 1000

6

6

DIVERSION CHANNEL 1 DETAIL REFER C105-003 N.T.S

MAX WATER LEVEL 160mm 1

1 1000

6

6

DIVERSION CHANNEL 2 DETAIL

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER DETAILS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-307

B

Mar 06, 2024 - 9:29am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

REFER C105-003 N.T.S


NOTES: PITS AND LID SLABS TO BE CONSTRUCTED FROM 40MPa CONCRETE WITH 40 COVER U.N.O 2

PIPE SIZE - mm 900 1050 1200 1350 1500

-

PRECAST CONCRETE LINTEL NOT SHOWN FOR CLARITY

℄ PIT ℄ OPENING AND LINTEL

MIN DEPTH OF PIPE - mm 1800 1950 2100 2250 2400

1 -

600

1/N16 OR 2/N12 TRIMMERS KERB LIP LINE

OUTSIDE EDGE OF FRAME TO BE FLUSH WITH KERB LIP LINE

'X'

'D '

'X'

150 TYP.

150 TYP.

1/N16 OR 2/N12 TRIMMERS ALL AROUND 'D' + 600 LONG CRANK AS REQUIRED

TYPICAL TRIMMER BAR DETAIL AT PIPE OPENING N.T.S DETAIL ONLY REQUIRED WHERE DIMENSION 'X' EXCEEDS 300mm

TYPICAL OVERSIZED KERB INLET PIT PLAN DETAIL

FOR WALL REINF. DETAILS REFER SECTIONS

℄ OPENING AND LINTEL

N12-200 E.W. CENTRAL IN BASE (TYP).

SECTION

1

N.T.S

-

330 650

T

N12-200 EACH WAY CENTRAL WHERE PIT < 2000D N12 -150 E.W. CENTRAL FOR 2000-2500D.

MASS CONCRETE BENCHING. SEE NOTE 15 FOR DETAILS ON C609-301

CJ

SEE NOTE 16 FOR DETAILS ON C609-301

N12-200 STARTER BARS LAP 500 WITH WALL REINFORCEMENT AND COG 200 INTO BASE SLAB

CJ

CJ

150

2100 MAX

150

SECTION

2

N.T.S

-

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-30.dwg

150

TYPICAL PIT CORNER DETAIL

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER DETAILS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-308

B

Mar 06, 2024 - 9:30am

2100 MAX

PLAN

200 2500 MAX

3N16 EXTRA

CJ

150

N12-200 TOP AND BOTTOM EACH WAY

SCALE 1:20

200

CJ

T

200

200

CONCRETE GROUT MAKE UP AS REQUIRED TYP. MAXIMUM MAKE UP IS 100MM

900

CJ

LIP LEVEL

1800 GUTTER TRANSITION AS REQUIRED

℄ PIT

MASS CONCRETE BENCHING. SEE NOTE 15 FOR DETAILS ON C609-301

DEPTH TO SUIT LINTEL

500 MIN

COUNCIL APPROVED PRECAST CONCRETE LINTEL

100 MIN

1800 GUTTER TRANSITION AS REQUIRED

SAG LINTEL SHOWN. PIT TO BE POSITIONED TO SUIT REQUIRED LINTEL CONFIGURATION.

TOP OF KERB LINE

FOR ROLL KERB & GUTTER LINTEL TO BE RAISED 30mm. TRANSITION OVER 1800mm

450 LAP TYP.

N.T.S


LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

2-1 0.1530ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20

/

/

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

80 /

/

/

TC 84.03 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-401

B

Mar 06, 2024 - 9:30am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

1-1 0.1911ha

ADJOINS SHEET 2

/

/

/

/

/

/

/

/

/

/

/

1-2 0.0240ha

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100

/

/

/

/

/

/

/

/

/

/

/

40

/ /

/

200 /

183.84 CTP 183.87

/

180

/

170.08

/

160

/

140

/

120

/

/

/

1-3 0.0675ha

/

LEY WAY

/

/

/

/

/

CAMDEN VA L

/

0.00

/

ADJOINS SHEET 2

STORMWATER CATCHMENT AREA


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

500

480

340

TC 344.60

/

/

/

/

/

/

/

320

360 CT 360.02

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

289.31

380

/

/

/

/

/

/

/

/

/

/

/

280

400

/

/

/

/

/

/

/

/

/

/

/

/

/

260

420

/

297.63 300

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

240

460 /

236.26

440

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220 220.07 CT

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

7-1 0.1891ha

CAMDEN VALLEY WAY

5-1 0.1950ha /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

4-6 0.0448ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

100 102.83

4-5 0.0437ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

2-1 0.1530ha

/

/

183.84 CTP 183.87

STORMWATER CATCHMENT AREA

/

/

6-1 0.1413ha

/

4-7 0.1327ha

/

/

/

/

/

/

/

/

/

180

ADJOINS SHEET 1

LEGEND

/

4-4 0.0370ha

1-1 0.1911ha

80

CT 71.44 4-3 0.0355ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

60 / / / / / /

/ / / / /

/

/ / / / /

/

/

/

/

/

/

/

/

/

/

4-2 0.3040ha SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-402

B

Mar 06, 2024 - 9:30am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

/ / /

ADJOINS SHEET 3

0.00

/

/

/

/

/

/

/

/

/

/

/

/

HILDE

/

/

/

/

/

/

/

/

/

/

R STR

20 ADJOINS SHEET 1

/

EET

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 35. 97 40 4-1 0.0656ha


/

/

/

/ /

/

/

LEGEND

/

/

/ /

/ /

/

/

/

/

/

/

/ /

/

/

ADJOINS SHEET 5

/

ADJOINS SHEET 5

/

/

/

160

/

/ /

/

/

/

/

/

/

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

STORMWATER CATCHMENT AREA

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/ / / / / /

/ / / / /

/ / / / /

/ /

/

/

/

/

/

/

/

/

200

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

KIRKHAM LANE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

180

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

220

240

/ / / /

800

780

760

740

/

/ /

/ /

/ / / / / /

/

/

/

/

720

/

/

/

640

255.48 257.25 260

700

/ / /

660

/

/

/

/

/

/

/

/

/

/

/

680

671.96 CT 674.84

/

/ / / / /

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

/

/

667.41

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

278.06 0.00 TC 0.05

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

8-3 0.0739ha

/

/

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

8-2 0.0743ha /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

9-4 0.3094ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

CAMDEN VALLEY WAY

/

/

/

/

/

/

/ /

/

/

/

/

7-1 0.1891ha

/

/

/

7-2 0.0958ha

/

/

/

/

/

/

/

8-4 0.0416ha TC 269 .56

/

20

9-5 0.4749ha

40.00 10-2 0.1262ha

CT 59.76 60

23-1 2.9620ha

ADJOINS SHEET 6 / /

5

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

/

0

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-403

B

Mar 06, 2024 - 9:30am

100

120

ADJOINS SHEET 6

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

80

ADJOINS SHEET 4

ADJOINS SHEET 2

11-7 0.0441ha

LIZ KERNOHAN DRIVE

10-1 0.1503ha


LEGEND

//

//

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

940

920

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

945.79

/

/

/

/

/

/

9-2 0.0060ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

8-1 0.1334ha /

/

/

/

900

880

820

840

//

800

860 //

/

/ /

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

/

/

/

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TC 864.55

ADJOINS SHEET 3

STORMWATER CATCHMENT AREA

/

9-3 0.2738ha

9-4 0.3094ha

9-1 0.3995ha

ADJOINS SHEET 3

23-1 2.9620ha

/ / /

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-404

B

Mar 06, 2024 - 9:30am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

9-5 0.4749ha


LEGEND STORMWATER CATCHMENT AREA

0.00 / /

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

20

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

40

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

60

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / / / / / / /

/ / / / / / / /

/ /

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

KIRKHAM LANE

/

/ /

/ / / / / / / / / /

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/ /

80

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

100

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

120

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/ /

/

/ /

/

/ /

/

/

/

/

/ /

/

/

/

/

160

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-405

B

Mar 06, 2024 - 9:30am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

/

140


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 3 STORMWATER CATCHMENT AREA

120 / /

/

TC 127.23

/

/

/

/ /

/ /

/

/

/

/

/

/ / /

/

/

11-6 0.0715ha

/

/

/

/ / /

/

/

/

/

/

/

/

/

/ / /

/ /

/ /

/

/

/

/

140

/ /

/

/

/ /

/ /

/ /

/ /

/ /

23-1 2.9620ha

/ /

/ /

/ /

/

/

/

/

/

/

/

12-1 0.0737ha

/

/

/

/ /

/ /

/ /

/ /

/ /

/ /

160

/ /

/ /

/

/

/

/

/ / /

/ /

/ /

/ /

/

/

/ /

/ /

/

/

/ /

/

/

/ /

/ /

/

11-5 0.0479ha

/

/ /

/

180

/

/ /

/ /

/ /

/

/ /

/

/

/

/ / /

/ /

/

/

/ /

/ /

/

/

/

/

/

/

/ /

/

/

/

53

/

/

0 201. 0 2 T C

/

/

14-5 0.3530ha

14-2 0.1711ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

60

/

8709.00

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ / /

/

/

/

/

/

/

/ /

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

3

/

/

/ /

/

/

/

/

/

/

/

/

E IV

/

E .7 RH249

/

/

/

DR

/

14-3 0.0606ha /

/

AN

/

E B N I

/

/

2

E G R

/

/

OH RN

KE

/

90. 08

/

/

/

IR C S

R

40

20

/

LIZ

/

/

.59

/

/

/

IT U C

40 C 40 T

/

/

/

11-4 0.0767ha

/

/

13-1 0 22 .46 0.2458ha 4 22

/ /

/ /

/

0.0

/

0

/

/

/

0

/

26

/ / /

/ /

11-3 0.0364ha

/

/ / /

/ / /

/ / / / / / /

0

/

28

/

14-4 0.1956ha / / / /

/ / / /

11-2 0.0305ha

/ /

/ / / /

/ / / /

2

/

0

.0 95

/

0

/ / /

/ /

15-1 0.0530ha

/

30

/

/ /

/

/

/

/

/

/

/ /

/

/ / /

/ /

/

/ /

/ /

/

/

/ / /

/ /

/

/

/ / /

/

/

/

/ /

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

.60 2 0 32 C 32 T

/

/

/ /

/

/

/ / / / / / / / / / /

/ / / / / /

/ / /

11-1 0.0738ha /

/

/

/

/

/

/

/

/

/

/ / /

/ / / /

/

/ / / / / / / / / /

/

/ / / / / / / / / / / /

/

0

/ /

34

/ / / / /

/ / / / / /

/ / / / / / /

/ / / / /

/ / / / / / /

/ / / / / / / /

/ / / /

/ / / /

22-1 0.0289ha

/ / /

/ / / /

/ /

ET

/ /

/

/ /

/ /

S 360 DJOIN A

E SH

7

/ / / /

/ / / /

/ /

/ / / / / /

/ / / /

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-406

B

Mar 06, 2024 - 9:30am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

/

380


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

GRIMES AVENUE

/

57.75 40 41.00 CT 45.42

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

ADJOINS SHEET 8

/

STORMWATER CATCHMENT AREA

58

C2 6.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

CT

/

/

/

/

/

/

/

/

/

/

/

18-2 0.0359ha

/

0

/

56 0

/

/

0.0

480

54 8

.73

540

/

498 TC 500

/

.07

20

520

527.72

T

18-1 0.0788ha

/

/

460

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

58 0

/ / / / / / / / / / / / / /

EIN RH

420 .36 3 2 4 CT

/

/

/

/

440

/

/ / / / / / /

/ / / / / / / /

4.0 0

62 0

/ / / /

62

/ /

/

/

/

/

/

/

64

/

0

/

/

/

/

/

/

/

/

/

/

38

/

/

IT

CU 0

R

/

CIR

/

0 40

S ER

N

E

60 0

/

/

/

RG BE

E K Z LI

HA O N

IV R D

/

/

/

/

/

/

36 0

/

66

/

0

/

/

/

JO AD

720

700

679.

680 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

T6 EE SH

64

/

/

/

/

S IN

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

22-1 9ha 0.028

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

KNIGHT STREET

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6 ET

E SH

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-407

B

Mar 06, 2024 - 9:30am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


/

/

/

/

/

/

/

/

/

/

STORMWATER CATCHMENT AREA

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

1040

1020

1000

980 /

/

20-1 0.0993ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

960

940

920

879.00 880

870.98

860

840

/ / / / /

/

800

780

760 /

900 900.58

ADJOINS SHEET 9 /

/

740

720 /

820

ADJOINS SHEET 7

LEGEND

/

21-1 0.0930ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

LIZ KERNOHAN DRIVE

/

/ / / /

/

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-408

B

Mar 06, 2024 - 9:31am

ADJOINS SHEET 9

ADJOINS SHEET 7

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND

1184.83

1180

/

/

/

/

/

/

/

/

1160

/

/

/

/

/

/

/

1140 1144.00 CT 1145.93

/

/

/

CT 1 TC 1 112.23 113.9 9 1120

1100

TC 1091.21

1080

/

/

/

/

/

1040

/

1060

/

/

/

/

/

/

/

ADJOINS SHEET 8

STORMWATER CATCHMENT AREA

/

/

/ / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

20-1 0.0993ha

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

19-1 0.1110ha

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CATCHMENT PLAN SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-409

B

Mar 06, 2024 - 9:31am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-40.dwg

LIZ KERNOHAN DRIVE


Pit Name

10

1-1

0.1911

10

1-2

10

3-1

10

0.024

0.0675

2-3

10

4-1

10

4-2

10

4-3

10

4-4

10

4-5

10

4-6

10

4-7

10

7-1

10

7-2

10

8-1

10

8-2

10

8-3

10

8-4

10

9-1

10

9-2

10

9-3

10

9-4

10

9-5

10

10-1

10

10-2

10

10-3

10

11-1

10

11-2

10

11-3

10

11-4

10

11-5

10

11-6

10

0.0656

0.304

0.0355

0.037

0.0437

0.0448

0.1327

0.1891

0.0958

0.1334

0.0734

0.0748

0.041

0.4008

0.0051

0.2734

0.3094

0.4719

0.0959

0.1511

0.1262

0.0738

0.0305

0.0364

0.0767

0.0479

0.0715

16-2

10

12-1

0.0737

LandUse

Percentage

Constant Flow Time (minutes)

EIA

90

5

5

Total Time tc (minutes)

RIA

0

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

0

RIA

0

PA

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

60

5

5

RIA

0

0

0

PA

40

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

50

5

5

RIA

0

0

0

PA

50

10

0

EIA

90

5

5

RIA

0

0

PA

10

EIA

INLET DESIGN

Overflows Approaching Pit Peak Sub-Catchment Origin of Flow Depth x Flowrate Approach Flows Flowrate Width Velocity (m3/s) (m3/s) (m) (m2/s)

0.47

375

64.8

64.578

64.98

64.825

1.08

5.9

65.05

65.688

0.63

1-1

0.008

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.008

0

0.064

9.022

0.98

375

64.528

64.44

64.793

64.772

0.77

1.8

64.82

65.977

1.15

1-2

0.022

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.022

0

0.081

4.557

1.01

375

64.4

64.354

64.73

64.721

0.79

1.6

64.77

66

1.23

3-1

IAD Pit 100% Capture

IAD Pit 100% Capture

0

0

0.149

4.114

1

375

64.354

64.313

64.637

64.581

1.76

1.2

64.72

66.028

1.31

2-3

0.022

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.022

0

0.02

17.691

1

450

64.95

64.773

65.167

65.151

0.27

5.9

65.17

66.143

0.98

4-1

0.101

3.6m Opening HEC22

3.6m Opening 3% Fall 3% Grade

0.101

0.006

0.107

27.642

0.51

450

64.773

64.631

65.003

64.941

1.31

5.9

65.15

66.179

1.03

4-2

4-1

0

0

0

0.012

4-2

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.012

0

0.123

10.494

1.25

450

64.631

64.5

64.892

64.834

1.28

1.4

64.94

66.124

1.18

4-3

0.012

4-3

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.012

0

0.134

21.989

0.75

450

64.5

64.336

64.773

64.676

1.32

1.7

64.83

66.03

1.2

4-4

0.014

4-4

0.005

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.014

0

0.146

41.216

1

450

64.336

63.925

64.602

64.325

1.49

1.7

64.68

65.845

1.17

4-5

0.015

4-5

0.008

0.62

0.03

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.02

0

0.159

14.03

1

450

63.925

63.784

64.208

64.152

1.51

2.3

64.32

65.351

1.03

4-6

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.044

0.005

0.192

10.577

0.99

450

63.784

63.679

64.09

63.95

1.92

1.5

64.15

65.34

1.19

4-7

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.064

0

0.059

33.013

0.52

375

64.138

63.965

64.33

64.253

1.04

5.9

64.43

65.013

0.59

7-1

0.032

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.032

0

0.088

12.907

0.5

375

63.965

63.9

64.195

64.117

1.33

1.9

64.25

65.329

1.08

7-2

0.044

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.044

0.005

0.035

69.307

4.91

375

72.1

68.7

72.279

68.893

0.66

5.9

72.29

73.245

0.96

8-1

0.044

0.063

7-2

0.001

0.24

0

0.024

8-1

0.022

1.26

0.05

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.046

0.001

0.056

71.09

5.2

375

68.7

65

68.871

65.246

1.13

2

68.89

69.832

0.94

8-2

0.025

8-2

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.025

0.001

0.076

20.372

1.47

375

65

64.7

65.201

64.947

1.26

1.8

65.25

66.644

1.4

8-3

0.014

8-3

0.007

0.63

0.03

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.022

0

0.088

30.178

1.66

375

64.7

64.2

64.917

64.363

1.92

1.3

64.95

66.03

1.08

8-4

Surface Inlet Sag Pits

1200SQ SI Sag Pit

0.099

0.022

0.077

6.64

3.25

375

74.8

74.584

75.002

74.84

1.27

5.9

75.08

75.904

0.82

9-1

0.099

0.002

9-1

0

0

0

1.2m Opening HEC22

1.2m Opening 3% Fall 5% Grade

0.002

0

0.098

46.053

4.7

375

74.584

72.42

74.813

72.755

1.39

1.6

74.84

75.674

0.83

9-2

0.079

9-2

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.079

0.008

0.169

72.543

5.27

375

72.42

68.6

72.722

68.916

1.78

4

72.75

73.557

0.8

9-3

0.09

9-3

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.09

0.018

0.233

80.553

4.1

450

68.55

65.25

68.888

66.203

1.82

1.1

68.92

69.934

1.02

9-4

0.156

9-4

0

0

0

3.6m Opening HEC22

3.6m Opening 3% Fall 1% Grade

0.156

0.022

0.367

45.717

1.42

450

65.2

64.55

65.746

64.959

2.42

1.6

66.2

66.371

0.17

9-5

IAD Pit 100% Capture

IAD Pit 100% Capture

0.022

0

0.022

9.601

6.4

375

65.464

64.85

65.61

65.197

0.55

5.9

65.61

66.681

1.07

10-1

3.0m Opening HEC22

3.0m Opening 3% Fall 3% Grade

0.05

0

0.08

18.923

0.53

375

64.8

64.7

65.037

64.997

1.09

5.9

65.2

65.98

0.78

10-2

3.0m Opening HEC22

3.0m Opening 3% Fall 3% Grade

0.042

0

0.117

20.624

0.48

375

64.65

64.55

64.946

64.801

1.48

1.8

65

65.827

0.83

10-3

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.024

0

0.025

21.323

2.34

375

72

71.5

72.143

71.643

0.65

5.9

72.14

73.373

1.23

11-1

0.022

0

10

0

12-1

0

0

0

90

5

5

10-2

0

0

0

RIA

0

0

0

PA

10

10

0

EIA

90

5

5 0 0

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

10

0

PA

10

EIA

0

RIA

0

PA

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

Water Pipe Pressure Surface Flow Surface Freeboard Change Pit Level Velocity Elevation (m) Name Coeff. (m) (m/s) (m) Ku.

46.846

0

90

D/S HGL in Pipe (m)

0.057

0

0

EIA

U/S HGL in Pipe (m)

0

0

10-1

0

Pipe Diameter (mm)

D/S Pipe Invert Level (m)

0.063

0

0

10

Pipe Slope (m)

2.4m Opening 3% Fall 1% Grade

1-2

0

0

Reach Length (m)

U/S Pipe Invert Level (m)

2.4m Opening HEC22

0.063

0

10

Peak Flow in Pipe (m³/s)

Inlet Size

0

PA

Overflow Total Leaving Approach Pit Bypass Flow Flow (m³/s) (m³/s)

PIT RESULTS

Inlet Family

9-5

RIA

PIPE SYSTEM DESIGN

0.05

0.042

11-7 0.024

0.01

11-1

0.013

0.94

0.06

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.025

0

0.032

26.261

2.28

375

71.5

70.9

71.643

70.982

1.76

1.6

71.64

72.988

1.35

11-2

0.012

11-2

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.012

0

0.5

53.781

3.03

750

70.5

68.87

70.934

69.304

1.89

1.9

70.94

72.301

1.36

11-3

0.025

11-3

0.001

0.18

0.02

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.027

0

0.536

35.138

3.35

750

68.853

67.676

69.302

68.068

2.3

1

69.3

70.416

1.11

11-4

0.016

11-4

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 5% Grade

0.016

0

0.547

41.725

3.6

750

67.676

66.175

68.068

67.078

2.34

0.5

68.07

69.178

1.11

11-5

0.024

11-5

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.024

0

0.194

2.87

1.05

375

66.155

66.125

66.716

66.681

1.76

2.3

67.08

67.646

0.57

11-6

IAD Pit 100% Capture

IAD Pit 100% Capture

0

0.194

4.046

1.11

375

66.125

66.08

66.5

66.397

1.95

1.5

66.68

67.843

1.16

16-2

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.024

0.034

19.1

1.02

375

66.37

66.175

67.086

67.078

0.31

4.2

67.11

68.035

0.92

12-1

0.024

13-1

0

0

0

0.001

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-50.dwg

Design AEP %

Sub-Catchment Area (ha)

TIME AND RUNOFF

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CALCULATIONS 10% AEP SHEET 1 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-501

B

Mar 06, 2024 - 9:31am

LOCATION AND LAND-USE


Pit Name

10

1-1

0.1911

10

1-2

10

3-1

10

0.024

0.0675

2-3

10

4-1

10

4-2

10

4-3

10

4-4

10

4-5

10

4-6

10

4-7

10

7-1

10

7-2

10

8-1

10

8-2

10

8-3

10

8-4

9-1

10

10

9-2

10

9-3

10

9-4

10

9-5

0.0656

0.304

0.0355

0.037

0.0437

0.0448

0.1327

0.1891

0.0958

0.1334

0.0734

0.0748

0.041

0.4008

0.0051

0.2734

0.3094

0.4719

LandUse

Percentage

Constant Flow Time (minutes)

Total Time tc (minutes)

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

10

0

PA

10

EIA

0

RIA

0

PA

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5 0

RIA

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

60

5

5

RIA

0

0

0

PA

40

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

INLET DESIGN

Overflows Approaching Pit Peak Sub-Catchment Origin of Flow Depth x Flowrate Approach Flows Flowrate Width Velocity (m3/s) (m3/s) (m) (m2/s)

PIPE SYSTEM DESIGN Overflow Total Leaving Approach Pit Bypass Flow Flow (m³/s) (m³/s)

Peak Flow in Pipe (m³/s)

Reach Length (m)

Pipe Slope (m)

PIT RESULTS

Pipe Diameter (mm)

U/S Pipe Invert Level (m)

D/S Pipe Invert Level (m)

U/S HGL in Pipe (m)

D/S HGL in Pipe (m)

Pipe Water Pressure Surface Flow Freeboard Surface Change Pit Level Velocity Elevation (m) Name Coeff. (m) (m/s) (m) Ku.

Inlet Family

Inlet Size

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.063

0

0.057

46.846

0.47

375

64.8

64.578

64.98

64.825

1.08

5.9

65.05

65.688

0.63

1-1

0.008

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.008

0

0.064

9.022

0.98

375

64.528

64.44

64.793

64.772

0.77

1.8

64.82

65.977

1.15

1-2

0.022

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.022

0

0.081

4.557

1.01

375

64.4

64.354

64.73

64.721

0.79

1.6

64.77

66

1.23

3-1

IAD Pit 100% Capture

IAD Pit 100% Capture

0

0

0.149

4.114

1

375

64.354

64.313

64.637

64.581

1.76

1.2

64.72

66.028

1.31

2-3

0.022

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.022

0

0.02

17.691

1

450

64.95

64.773

65.167

65.151

0.27

5.9

65.17

66.143

0.98

4-1

0.101

3.6m Opening HEC22

3.6m Opening 3% Fall 3% Grade

0.101

0.006

0.107

27.642

0.51

450

64.773

64.631

65.003

64.941

1.31

5.9

65.15

66.179

1.03

4-2

0.063

1-2

0

0

0

4-1

0

0

0

0.012

4-2

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.012

0

0.123

10.494

1.25

450

64.631

64.5

64.892

64.834

1.28

1.4

64.94

66.124

1.18

4-3

0.012

4-3

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.012

0

0.134

21.989

0.75

450

64.5

64.336

64.773

64.676

1.32

1.7

64.83

66.03

1.2

4-4

0.014

4-4

0.005

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.014

0

0.146

41.216

1

450

64.336

63.925

64.602

64.325

1.49

1.7

64.68

65.845

1.17

4-5

0.015

4-5

0.008

0.62

0.03

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.02

0

0.159

14.03

1

450

63.925

63.784

64.208

64.152

1.51

2.3

64.32

65.351

1.03

4-6

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.044

0.005

0.192

10.577

0.99

450

63.784

63.679

64.09

63.95

1.92

1.5

64.15

65.34

1.19

4-7

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.064

0

0.059

33.013

0.52

375

64.138

63.965

64.33

64.253

1.04

5.9

64.43

65.013

0.59

7-1

0.032

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.032

0

0.088

12.907

0.5

375

63.965

63.9

64.195

64.117

1.33

1.9

64.25

65.329

1.08

7-2

0.044

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.044

0.005

0.035

69.307

4.91

375

72.1

68.7

72.279

68.893

0.66

5.9

72.29

73.245

0.96

8-1

0.044

0.063

7-2

0.001

0.24

0

0.024

8-1

0.022

1.26

0.05

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.046

0.001

0.056

71.09

5.2

375

68.7

65

68.871

65.246

1.13

2

68.89

69.832

0.94

8-2

0.025

8-2

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.025

0.001

0.076

20.372

1.47

375

65

64.7

65.201

64.947

1.26

1.8

65.25

66.644

1.4

8-3

0.014

8-3

0.007

0.63

0.03

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.022

0

0.088

30.178

1.66

375

64.7

64.2

64.917

64.363

1.92

1.3

64.95

66.03

1.08

8-4

Surface Inlet Sag Pits

1200SQ SI Sag Pit

0.099

0.022

0.077

6.64

3.25

375

74.8

74.584

75.002

74.84

1.27

5.9

75.08

75.904

0.82

9-1

0.099

0.002

9-1

0

0

0

1.2m Opening HEC22

1.2m Opening 3% Fall 5% Grade

0.002

0

0.098

46.053

4.7

375

74.584

72.42

74.813

72.755

1.39

1.6

74.84

75.674

0.83

9-2

0.079

9-2

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.079

0.008

0.169

72.543

5.27

375

72.42

68.6

72.722

68.916

1.78

4

72.75

73.557

0.8

9-3

0.09

9-3

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.09

0.018

0.233

80.553

4.1

450

68.55

65.25

68.888

66.203

1.82

1.1

68.92

69.934

1.02

9-4

0.156

9-4

0

0

0

3.6m Opening HEC22

3.6m Opening 3% Fall 1% Grade

0.156

0.022

0.367

45.717

1.42

450

65.2

64.55

65.746

64.959

2.42

1.6

66.2

66.371

0.17

9-5

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-50.dwg

Design AEP %

Sub-Catchment Area (ha)

TIME AND RUNOFF

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CALCULATIONS 10% AEP SHEET 2 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-502

B

Mar 06, 2024 - 9:31am

LOCATION AND LAND-USE


Pit Name

1

1-1

0.1911

1

1-2

3-1

1

0.024

0.0675

2-3

1

1

4-1

1

4-2

4-3

1

1

4-4

1

4-5

4-6

1

1

4-7

1

7-1

1

7-2

8-1

1

1

8-2

8-3

1

8-4

1

1

9-1

1

9-2

9-3

1

1

9-4

1

9-5

10-1

1

1

10-2

1

10-3

1

11-1

1

11-2

1

11-3

1

11-4

11-5

1

1

11-6

1

0.0656

0.304

0.0355

0.037

0.0437

0.0448

0.1327

0.1891

0.0958

0.1334

0.0734

0.0748

0.041

0.4008

0.0051

0.2734

0.3094

0.4719

0.0959

0.1511

0.1262

0.0738

0.0305

0.0364

0.0767

0.0479

0.0715

16-2

1

12-1

0.0737

LandUse

Percentage

Constant Flow Time (minutes)

Total Time tc (minutes)

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

10

0

PA

10

EIA

0

RIA

0

PA

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

60

5

5

RIA

0

0

0

PA

40

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

50

5

5

RIA

0

0

0

PA

50

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

0

RIA

0

PA

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

INLET DESIGN

Overflows Approaching Pit Peak Sub-Catchment Origin of Flow Depth x Flowrate Approach Flows Flowrate Width Velocity (m3/s) (m3/s) (m) (m2/s)

PIPE SYSTEM DESIGN Overflow Leaving Pit

Peak Flow in Pipe (m³/s)

Reach Length (m)

Pipe Slope (m)

PIT RESULTS

Pipe Diameter (mm)

U/S Pipe Invert Level (m)

D/S Pipe Invert Level (m)

U/S HGL in Pipe (m)

D/S HGL in Pipe (m)

Water Pipe Pressure Surface Flow Surface Freeboard Change Pit Level Velocity Elevation (m) Name Coeff. (m) (m/s) (m) Ku.

Inlet Family

Inlet Size

Total Approach Flow (m³/s)

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.104

0

0.084

46.846

0.47

375

64.8

64.578

65.299

65.192

0.76

5.9

65.47

65.688

0.22

1-1

0.012

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.012

0

0.095

9.022

0.98

375

64.528

64.44

65.125

65.099

0.86

1.8

65.19

65.977

0.78

1-2

0.034

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.034

0.002

0.122

4.557

1.01

375

64.4

64.354

65

64.978

1.11

1.6

65.1

66

0.9

3-1

IAD Pit 100% Capture

IAD Pit 100% Capture

0

0

0.227

4.114

1

375

64.354

64.313

64.729

64.651

2.16

1.2

64.98

66.028

1.05

2-3

0.033

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.033

0

0.032

17.691

1

450

64.95

64.773

66.042

66.04

0.2

5.9

66.05

66.143

0.09

4-1

0.151

3.6m Opening HEC22

3.6m Opening 3% Fall 3% Grade

0.151

0.034

0.143

27.642

0.51

450

64.773

64.631

65.796

65.727

0.9

5.9

66.04

66.179

0.14

4-2

0.095

1-2

0

0

0

4-1

0.009

1.06

0.02

Bypass Flow (m³/s)

0.018

4-2

0.001

0.32

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.019

0.009

0.185

10.494

1.25

450

64.631

64.5

65.628

65.584

1.16

1.4

65.73

66.124

0.4

4-3

0.018

4-3

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.018

0.001

0.21

21.989

0.75

450

64.5

64.336

65.431

65.312

1.32

1.7

65.58

66.03

0.45

4-4

0.022

4-4

0.008

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.022

0

0.231

41.216

1

450

64.336

63.925

65.128

64.858

1.45

1.7

65.31

65.845

0.53

4-5

0.022

4-5

0.021

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.038

0

0.252

14.03

1

450

63.925

63.784

64.565

64.456

1.59

2.3

64.86

65.351

0.49

4-6

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.066

0.016

0.3

10.577

0.99

450

63.784

63.679

64.234

64.06

2.09

1.5

64.46

65.34

0.88

4-7

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.102

0

0.087

33.013

0.52

375

64.138

63.965

64.512

64.367

0.79

5.9

64.64

65.013

0.38

7-1

0.048

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.048

0.003

0.127

12.907

0.5

375

63.965

63.9

64.34

64.163

1.54

1.9

64.37

65.329

0.96

7-2

0.066

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.066

0.017

0.047

69.307

4.91

375

72.1

68.7

72.256

68.945

1.07

5.9

72.32

73.245

0.92

8-1

0.066

0.094

7-2

0.008

0.83

0.06

0.036

8-1

0.057

1.62

0.23

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.093

0.01

0.085

71.09

5.2

375

68.7

65

68.912

65.322

1.31

2.1

68.95

69.832

0.89

8-2

0.037

8-2

0.016

1.23

0.07

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.053

0.008

0.118

20.372

1.47

375

65

64.7

65.252

65.035

1.5

1.8

65.32

66.644

1.32

8-3

0.02

8-3

0.045

1.52

0.11

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.065

0.002

0.142

30.178

1.66

375

64.7

64.2

64.976

64.416

2.16

1.3

65.04

66.03

0.99

8-4

Surface Inlet Sag Pits

1200SQ SI Sag Pit

0.166

0.057

0.121

6.64

3.25

375

74.8

74.584

75.139

74.944

1.15

5.9

75.28

75.904

0.63

9-1

0.166

0.003

9-1

0

0

0

1.2m Opening HEC22

1.2m Opening 3% Fall 5% Grade

0.003

0.016

0.163

46.053

4.7

375

74.584

72.42

74.872

73.598

1.8

1.6

74.93

75.674

0.75

9-2

0.123

9-2

0.159

9.97

0.03

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.282

0.045

0.255

72.543

5.27

375

72.42

68.6

72.768

69.051

2.38

4.2

73.52

73.557

0.04

9-3

0.139

9-3

0.007

2.49

0.01

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.146

0.07

0.376

80.553

4.1

450

68.55

65.25

68.95

66.489

2.52

1.3

69.03

69.934

0.9

9-4

0.235

9-4

0.004

0.45

0.02

3.6m Opening HEC22

3.6m Opening 3% Fall 1% Grade

0.239

0.232

0.413

45.717

1.42

450

65.2

64.55

65.931

64.971

2.67

1.6

66.49

66.371

0

9-5

IAD Pit 100% Capture

IAD Pit 100% Capture

0.037

0

0.042

9.601

6.4

375

65.464

64.85

66.157

66.154

0.38

5.9

66.18

66.681

0.5

10-1

3.0m Opening HEC22

3.0m Opening 3% Fall 3% Grade

0.077

0.159

0.153

18.923

0.53

375

64.8

64.7

65.825

65.749

1.39

5.9

66.14

65.98

0

10-2

3.0m Opening HEC22

3.0m Opening 3% Fall 3% Grade

0.064

0.007

0.247

20.624

0.48

375

64.65

64.55

65.303

64.897

2.31

1.8

65.68

65.827

0.15

10-3

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.037

0.004

0.036

21.323

2.34

375

72

71.5

72.175

71.675

0.72

5.9

72.17

73.373

1.2

11-1

0.037

0.075

0.063

9-5

0

0

0

10-1

0.002

0.14

0.04

12-1

0

0

0

10-2

0.001

0.11

0

11-7 0.037

0.015

11-1

0.084

2.02

0.14

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.099

0

0.053

26.261

2.28

375

71.5

70.9

71.675

71.089

1.04

1.5

71.67

72.988

1.31

11-2

0.018

11-2

0.001

0.22

0

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.019

0

0.767

53.781

3.03

750

70.5

68.87

71.032

69.457

2.29

1.9

71.07

72.301

1.23

11-3

0.038

11-3

0.01

0.55

0.04

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.048

0.002

0.866

35.138

3.35

750

68.853

67.676

69.415

68.193

2.67

1

69.44

70.416

0.97

11-4

0.024

11-4

0.005

0.77

0.01

1.8m Opening HEC22

1.8m Opening 3% Fall 5% Grade

0.029

0.001

0.885

41.725

3.6

750

67.676

66.175

68.18

67.345

2.8

0.5

68.18

69.178

1

11-5

0.036

11-5

0

0

0

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.036

0.001

0.227

2.87

1.05

375

66.155

66.125

66.847

66.803

2.06

2.3

67.31

67.646

0.34

11-6

IAD Pit 100% Capture

IAD Pit 100% Capture

0

0.227

4.046

1.11

375

66.125

66.08

66.5

66.418

2.16

1.5

66.78

67.843

1.06

16-2

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.037

0.073

19.1

1.02

375

66.37

66.175

67.377

67.345

0.66

4.2

67.41

68.035

0.63

12-1

0.037

13-1

0

0

0

0.04

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-51.dwg

Design AEP %

Sub-Catchment Area (ha)

TIME AND RUNOFF

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CALCULATIONS 1% AEP SHEET 1 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-511

B

Mar 06, 2024 - 9:31am

LOCATION AND LAND-USE


Pit Name

1

1-1

0.1911

1

1-2

3-1

1

0.024

0.0675

2-3

1

1

4-1

1

4-2

4-3

1

1

4-4

1

4-5

4-6

1

1

4-7

1

7-1

1

7-2

8-1

1

1

8-2

8-3

1

8-4

1

1

9-1

1

9-2

9-3

1

1

9-4

1

9-5

0.0656

0.304

0.0355

0.037

0.0437

0.0448

0.1327

0.1891

0.0958

0.1334

0.0734

0.0748

0.041

0.4008

0.0051

0.2734

0.3094

0.4719

LandUse

Percentage

Constant Flow Time (minutes)

Total Time tc (minutes)

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

10

0

PA

10

EIA

0

RIA

0

PA

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

60

5

5

RIA

0

0

0

PA

40

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

75

5

5

RIA

0

0

0

PA

25

10

0

EIA

90

5

5

RIA

0

0

0

PA

10

10

0

INLET DESIGN

Overflows Approaching Pit Peak Sub-Catchment Origin of Flow Depth x Flowrate Approach Flows Flowrate Width Velocity (m3/s) (m3/s) (m) (m2/s)

PIPE SYSTEM DESIGN Overflow Leaving Pit

Peak Flow in Pipe (m³/s)

Reach Length (m)

Pipe Slope (m)

PIT RESULTS

Pipe Diameter (mm)

U/S Pipe Invert Level (m)

D/S Pipe Invert Level (m)

U/S HGL in Pipe (m)

D/S HGL in Pipe (m)

Water Pipe Pressure Surface Flow Surface Freeboard Change Pit Level Velocity Elevation (m) Name Coeff. (m) (m/s) (m) Ku.

Inlet Family

Inlet Size

Total Approach Flow (m³/s)

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.104

0

0.084

46.846

0.47

375

64.8

64.578

65.299

65.192

0.76

5.9

65.47

65.688

0.22

1-1

0.012

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.012

0

0.095

9.022

0.98

375

64.528

64.44

65.125

65.099

0.86

1.8

65.19

65.977

0.78

1-2

0.034

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.034

0.002

0.122

4.557

1.01

375

64.4

64.354

65

64.978

1.11

1.6

65.1

66

0.9

3-1

IAD Pit 100% Capture

IAD Pit 100% Capture

0

0

0.227

4.114

1

375

64.354

64.313

64.729

64.651

2.16

1.2

64.98

66.028

1.05

2-3

0.033

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.033

0

0.032

17.691

1

450

64.95

64.773

66.042

66.04

0.2

5.9

66.05

66.143

0.09

4-1

0.151

3.6m Opening HEC22

3.6m Opening 3% Fall 3% Grade

0.151

0.034

0.143

27.642

0.51

450

64.773

64.631

65.796

65.727

0.9

5.9

66.04

66.179

0.14

4-2

0.095

1-2

0

0

0

4-1

0.009

1.06

0.02

Bypass Flow (m³/s)

0.018

4-2

0.001

0.32

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.019

0.009

0.185

10.494

1.25

450

64.631

64.5

65.628

65.584

1.16

1.4

65.73

66.124

0.4

4-3

0.018

4-3

0

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.018

0.001

0.21

21.989

0.75

450

64.5

64.336

65.431

65.312

1.32

1.7

65.58

66.03

0.45

4-4

0.022

4-4

0.008

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.022

0

0.231

41.216

1

450

64.336

63.925

65.128

64.858

1.45

1.7

65.31

65.845

0.53

4-5

0.022

4-5

0.021

0

0

1.8m Opening HEC22

1.8m Opening 3% Fall 1% Grade

0.038

0

0.252

14.03

1

450

63.925

63.784

64.565

64.456

1.59

2.3

64.86

65.351

0.49

4-6

1.8m Opening HEC22

1.8m Opening 3% Fall 3% Grade

0.066

0.016

0.3

10.577

0.99

450

63.784

63.679

64.234

64.06

2.09

1.5

64.46

65.34

0.88

4-7

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.102

0

0.087

33.013

0.52

375

64.138

63.965

64.512

64.367

0.79

5.9

64.64

65.013

0.38

7-1

0.048

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.048

0.003

0.127

12.907

0.5

375

63.965

63.9

64.34

64.163

1.54

1.9

64.37

65.329

0.96

7-2

0.066

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.066

0.017

0.047

69.307

4.91

375

72.1

68.7

72.256

68.945

1.07

5.9

72.32

73.245

0.92

8-1

0.066

0.094

7-2

0.008

0.83

0.06

0.036

8-1

0.057

1.62

0.23

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.093

0.01

0.085

71.09

5.2

375

68.7

65

68.912

65.322

1.31

2.1

68.95

69.832

0.89

8-2

0.037

8-2

0.016

1.23

0.07

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.053

0.008

0.118

20.372

1.47

375

65

64.7

65.252

65.035

1.5

1.8

65.32

66.644

1.32

8-3

0.02

8-3

0.045

1.52

0.11

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.065

0.002

0.142

30.178

1.66

375

64.7

64.2

64.976

64.416

2.16

1.3

65.04

66.03

0.99

8-4

Surface Inlet Sag Pits

1200SQ SI Sag Pit

0.166

0.057

0.121

6.64

3.25

375

74.8

74.584

75.139

74.944

1.15

5.9

75.28

75.904

0.63

9-1

0.166

0.003

9-1

0

0

0

1.2m Opening HEC22

1.2m Opening 3% Fall 5% Grade

0.003

0.016

0.163

46.053

4.7

375

74.584

72.42

74.872

73.598

1.8

1.6

74.93

75.674

0.75

9-2

0.123

9-2

0.159

9.97

0.03

2.4m Opening HEC22

2.4m Opening 3% Fall 1% Grade

0.282

0.045

0.255

72.543

5.27

375

72.42

68.6

72.768

69.051

2.38

4.2

73.52

73.557

0.04

9-3

0.139

9-3

0.007

2.49

0.01

2.4m Opening HEC22

2.4m Opening 3% Fall 3% Grade

0.146

0.07

0.376

80.553

4.1

450

68.55

65.25

68.95

66.489

2.52

1.3

69.03

69.934

0.9

9-4

0.235

9-4

0.004

0.45

0.02

3.6m Opening HEC22

3.6m Opening 3% Fall 1% Grade

0.239

0.232

0.413

45.717

1.42

450

65.2

64.55

65.931

64.971

2.67

1.6

66.49

66.371

0

9-5

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C108-51.dwg

Design AEP %

Sub-Catchment Area (ha)

TIME AND RUNOFF

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

STORMWATER MANAGEMENT CALCULATIONS 1% AEP SHEET 2 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C108-512

B

Mar 06, 2024 - 9:31am

LOCATION AND LAND-USE


LEGEND ADJOINS SHEET 2

CAMDEN VALLEY WAY - P1

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS) HILDER STREET - P3 KIRKHAM LANE - P4 LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6 DRIVEWAY - D1 MEDIAN - M1 FOOTPATH - FP1

LANDSCAPED MEDIANS

200

183.84 CTP 183.87

180

170.08

160

140

120

100

80

60

40

CAMDEN VA L

TC 84.03

EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7

20

0.00

SHARED PATH - FP2

MAINTENANCE ACCESS PAD

LEY WAY

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-001

B

Mar 06, 2024 - 9:32am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

MCB1


CAMDEN VALLEY WAY - P1

ADJOINS SHEET 3

ADJOINS SHEET 1

LEGEND

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS) HILDER STREET - P3 KIRKHAM LANE - P4 LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6 DRIVEWAY - D1 MEDIAN - M1 FOOTPATH - FP1

EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7

500

480

460

440

MCB1

420

400

380

360 CT 360.02

TC 344.60

340

320

297.63 300

289.31

280

260

240

236.26

220 220.07 CT

SHARED PATH - FP2

LANDSCAPED MEDIANS

200

183.84 CTP 183.87

180

MCB1

MAINTENANCE ACCESS PAD

CAMDEN VALLEY WAY 100 102.83

80

CT 71.44

60 TC 35. 97 40 5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-002

B

Mar 06, 2024 - 9:32am

0.00 0

ADJOINS SHEET 3

HILDE

ADJOINS SHEET 1

R STR

20 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

EET

MC03


LEGEND ADJOINS SHEET 5

ADJOINS SHEET 5 CAMDEN VALLEY WAY - P1

ADJOINS SHEET 4

ADJOINS SHEET 2

160

180

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS)

KIRKHAM LAN E

HILDER STREET - P3 MCA2

KIRKHAM LANE - P4

200 LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6

220

DRIVEWAY - D1 MEDIAN - M1 FOOTPATH - FP1

MCB1

800

780

760

740

720

700

255.48 257.25 260

SHARED PATH - FP2

680

671.96 CT 674.84

667.41

660

640

MCB1

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

240

EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7 LANDSCAPED MEDIANS

TC 269.56 MAINTENANCE ACCESS PAD

CAMDEN VALLEY WAY

278.06 0.00 TC 0.05

CAMDEN VALLEY WAY

20

40.00

CT 59.76 60

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

5

ADJOINS SHEET 6

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-003

B

Mar 06, 2024 - 9:32am

0

100

120

ADJOINS SHEET 6

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

80

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

MCA1


LEGEND ADJOINS SHEET 3

CAMDEN VALLEY WAY - P1

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS) HILDER STREET - P3 KIRKHAM LANE - P4 LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6 DRIVEWAY - D1 MEDIAN - M1

EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7

945.79

940

900 MCB1

920

SHARED PATH - FP2

880

LANDSCAPED MEDIANS

ADJOINS SHEET 3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

MAINTENANCE ACCESS PAD

CAMDEN VALLEY WAY

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-004

B

Mar 06, 2024 - 9:32am

TC 864.55

840

820

800

860

FOOTPATH - FP1


LEGEND CAMDEN VALLEY WAY - P1

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS) HILDER STREET - P3 KIRKHAM LANE - P4 LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6 DRIVEWAY - D1 MEDIAN - M1

0.00

FOOTPATH - FP1 SHARED PATH - FP2

20 EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7 LANDSCAPED MEDIANS

40

MCA2

MAINTENANCE ACCESS PAD

KIRKHAM LANE

60

80

100

140

160 ADJOINS SHEET 3

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

ADJOINS SHEET 3

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-005

B

Mar 06, 2024 - 9:32am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

120


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 3

120

CAMDEN VALLEY WAY - P1

TC 127.23

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS)

140

HILDER STREET - P3 KIRKHAM LANE - P4

160

LIZ KERNOHAN DRIVE - P5

180

RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6 DRIVEWAY - D1

53

0 201. 0 2 T C

MEDIAN - M1

MCA1

.59

.46 4 2

2

OH RN

KE 0

DR

20

AN

24

RS E G

.73

0.0

0

E IV

9 24

R

90. 08

40 C 40 T

LIZ

8709.00

60

0

22

FOOTPATH - FP1

C R I C

SHARED PATH - FP2 EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7

UIT

LANDSCAPED MEDIANS

ER B IN 0 E H 26

MC01

MAINTENANCE ACCESS PAD

0

28

0

2

.0 95

0

30

.60 2 0 32 C 32 T

0

34

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

S 360 DJOIN A

7

380

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-006

B

Mar 06, 2024 - 9:32am

ET

E SH


CAMDEN VALLEY WAY - P1

ADJOINS SHEET 8

GRIMES AVENUE

LEGEND

MC02

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS)

57.75 40 41.00 CT 45.42

HILDER STREET - P3

58

C2 6.

520

.07

LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6

CT

DRIVEWAY - D1

0

460

56 0

0.0

480

54 8

.73

540

498 TC 500

20

527.72

T KIRKHAM LANE - P4

420 .36 3 2 4 CT

58 0

440

MEDIAN - M1 FOOTPATH - FP1 SHARED PATH - FP2

N

60 0

E

EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7 LANDSCAPED MEDIANS

62

62 0

R

38

0

E K Z LI

HA O N

IV R D

4.0 0

0 40

MCA1

64

0

MAINTENANCE ACCESS PAD

36 0

720

700

64

680

T6 EE SH

679.

S IN

66

0

JO AD 6 ET

E SH

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-007

B

Mar 06, 2024 - 9:33am

S IN

JO AD

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

MCA1


CAMDEN VALLEY WAY - P1

ADJOINS SHEET 9

ADJOINS SHEET 7

LEGEND

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS) HILDER STREET - P3 KIRKHAM LANE - P4 LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6 DRIVEWAY - D1 MEDIAN - M1 FOOTPATH - FP1 SHARED PATH - FP2 EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7 LANDSCAPED MEDIANS

1040

1020

1000

980

960

940

920

900 900.58

879.00 880

870.98

840

820

800

780

760

740

720

860

MAINTENANCE ACCESS PAD

MCA1

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-008

B

Mar 06, 2024 - 9:33am

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

ADJOINS SHEET 9

ADJOINS SHEET 7

LIZ KERNOHAN DRIVE


LEGEND ADJOINS SHEET 8

CAMDEN VALLEY WAY - P1

CAMDEN VALLEY WAY - P2A (ROUNDABOUT) CAMDEN VALLEY WAY INTERECTION - P2B (TCS) HILDER STREET - P3 KIRKHAM LANE - P4 LIZ KERNOHAN DRIVE - P5 RHEINBURGERS CIRCUIT AND GRIMES AVENUE - P6 DRIVEWAY - D1 MEDIAN - M1 FOOTPATH - FP1 SHARED PATH - FP2 EXISTING PAVEMENT TO BE REHABILITATED MILL AND RE-SHEET - P7

1184.83

1160

MCA1

1180

MAINTENANCE ACCESS PAD

1140 1144.00 CT 1145.93

CT 1 TC 1 112.23 113.9 9 1120

1100

TC 1091.21

1040

1060

1080

LANDSCAPED MEDIANS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT PLANS SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-009

B

Mar 06, 2024 - 9:33am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-00.dwg

LIZ KERNOHAN DRIVE


CAMDEN VALLEY WAY - P2A (DEEP LIFT ASPHALT-ROUNDABOUT)

CAMDEN VALLEY WAY - P1 DEEP LIFT ASPHALT DESIGN ESA 1.5x107

DESIGN FINISHED SURFACE LEVEL

DEEP LIFT ROUNDABOUT PAVEMENT ASPHALT INTERSECTION PAVEMENT DESIGN ESA 1.5x107

DESIGN FINISHED SURFACE LEVEL

80mm AC14 (A15E) 75mm AC20 (AR450) 75mm AC20 (AR450) 300mm SMZ

75mm AC14 (SBS POLYMER MODIFIED) 65mm AC20 (AR450) 65mm AC20 (AR450) 300mm SMZ

COMPACTED SUBGRADE MIN. CBR 4.5%

HILDER STREET - P3 GRANULAR 6 DESIGN ESA 1x10

DESIGN FINISHED SURFACE LEVEL 50mm AC14 (C450) 130mm DGSB20 435mm DGS40 COMPACTED SUBGRADE MIN. CBR 2.5%

COMPACTED SUBGRADE MIN. CBR 4.5%

KIRKHAM LANE- P4

CAMDEN VALLEY WAY - P2B

RHEINBURGERS CT AND GRIMES AVE - P6

GRANULAR 6 DESIGN ESA 1x10

DEEP LIFT ASPHALT - (TCS)

GRANULAR 6 DESIGN ESA 1X10

DESIGN FINISHED SURFACE LEVEL

DESIGN FINISHED SURFACE LEVEL

10mm AC14 (A14E) 60mm AC20 (AR450) 60mm AC20 (AR450) 300mm SMZ

50mm AC14 (A15E) 130mm DGSB20 380mm DGS40 COMPACTED SUBGRADE MIN. CBR 3.0%

COMPACTED SUBGRADE MIN. CBR 4.5%

DRIVEWAY - D1

LIZ KERNOHAN DRIVE - P5

CONCRETE

GRANULAR DESIGN ESA 1.5x10 7

DESIGN FINISHED SURFACE LEVEL

DESIGN FINISHED SURFACE LEVEL 50mm AC10 (C450) 130mm DGSB20 380mm DGS40 COMPACTED SUBGRADE MIN. CBR 3.0%

DESIGN FINISHED SURFACE LEVEL

125mm N32 CONCRETE WITH SL82 TOP (40 COVER) 50mm GRANULAR BEDDING LAYER COMPACTED SUBGRADE (100% SMDD)

50mm AC10 (C450) 170mm DGB20 180mm DGS40 300mm SMZ COMPACTED SUBGRADE MIN CBR 3%

FOOTPATH - FP1 CONCRETE

DESIGN FINISHED SURFACE LEVEL

100mm THICK N32 CONCRETE WITH SL72 TOP (40 COVER) 50mm GRANULAR BEDDING LAYER COMPACTED SUBGRADE (100% SMDD)

MEDIAN - M1 CONCRETE

DESIGN FINISHED SURFACE LEVEL

REHABILITATION OF EXISTING PAVEMENT - P8

125mm N32 CONCRETE WITH SL82 TOP (40 COVER) 50mm GRANULAR BEDDING LAYER COMPACTED SUBGRADE (100% SMDD)

MILL AND RE-SHEET SAWCUT AND MILL OUT NOM 30mm OF EXISTING ASPHALTIC CONCRETE. TRIM, PROOF ROLL, MAKE SMOOTH AND REPAIR ALL EXISTING DEFECTS. REPLACE WITH NOM 30mm AC10

SHARED PATH - FP2 CONCRETE

NOTE 125mm THICK N32 CONCRETE WITH SL82 TOP (40 COVER) 50mm GRANULAR BEDDING LAYER COMPACTED SUBGRADE (100% SMDD) \\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-30.dwg

DESIGN FINISHED SURFACE LEVEL

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT DETAILS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-301

B

Mar 06, 2024 - 9:33am

PAVEMENT AS SHOWN "EXISTING AC PAVEMENT TO BE RESHEETED" WILL BE REQUIRED TO BE BORE HOLED AND TESTED TO ASCERTAIN PAVEMENT CONDITION. CONTRACTOR IS TO ALLOW FOR PAVEMENT TO BE REMOVED AND REPLACED WITH NEW HEAVY DUTY PAVEMENT AC PAVEMENT TYPE 1, SUBJECT TO RESULTS OF BORE HOLE TESTING


NOMINAL KERB LINE/ SETOUT

150

150

20 RAD.

30 20 RAD.

30 180

EXISTING FLEXIBLE PAVEMENT

150

125

100

150

275

90

40 125

255

R5

NOMINAL KERB LINE/ SETOUT

150

5 RAD.

40

R300

1 in 12

75

5 RAD.

50

R5

30

350

150

150

NOMINAL KERB LINE/ SETOUT

SMZ

450

450

SAWCUT EXISTING PAVEMENT

225

180

ROLL KERB (RKG)

KERB AND GUTTER (K&G)

MOUNTABLE KERB (SF)

KERB ONLY (SM)

N.T.S REFER CAMDEN COUNCIL STD DRG SD02 FOR NOTES

N.T.S REFER CAMDEN COUNCIL STD DRG SD02 FOR NOTES

N.T.S REFER CAMDEN COUNCIL STD DRG SD02 FOR NOTES

N.T.S REFER CAMDEN COUNCIL STD DRG SD02 FOR NOTES

DEPRESS 3mm

630

SEALANT TYPE 'A'

TYPICAL DEEP LIFT ASPHALT CONNECTION TO EXISTING PAVEMENT N.T.S

6 SEALANT

SAW CUT OR FORMED JOINT

DEPRESS FABRIC MESH (CUT EVERY SECOND BAR) UNDER SAW CUT (TOP FABRIC IF TWO LAYERS)

SAW CUT

TYPICAL SAW CUT JOINT (SC) DETAIL

BREAKER TAPE

DJ

SCALE 1:2

W

75 TYP.

75 TYP.

SEALANT TYPE 'A'

SEALANT DOWEL CAP WITH EXPANSION SPACE

10

SC

175

BOND BREAKER

Ø20 GALV. DOWELS 400 LONG 200 CENTRES

25 R20-200 DOWELS 400 LONG FILLER

225 TYP.

25

BOND BREAKER

SC

TYPICAL EXPANSION JOINT (EJ) DETAIL

DOWELLED CONSTRUCTION JOINT (DJ) (CONNELLY JOINT)

3xW

25

W

=

T

=

100 NOM. 50 MIN. SAND SUBGRADE

3

W

SEALANT DETAIL

N.T.S

SL62 MESH 30 MIN. COVER (MUST NOT BE CONNECTED TO THE UNBONDED END OF THE DOWEL)

T\4

20

T

FILLER

300 MIN.

300

NOMINAL KERB LINE/ SETOUT 600

300 MIN.

N.T.S

W

N.T.S

T + 50

DJ

CONCRETE PAVEMENT

SUB-BASE

300

SUB-BASE

100

TYPICAL CONCRETE PAVEMENT DETAIL

TYPICAL EDGE BEAM (EB) DETAIL

N.T.S

N.T.S

TYPICAL PATH JOINTING PLAN N.T.S REFER LANDSCAPE ARCHITECT'S DRAWINGS FOR FURTHER DETAILS

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT DETAILS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

N.T.S.

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C109-302

B

Mar 06, 2024 - 9:33am

T

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C109-30.dwg

F.S.L

T

CONCRETE PAVEMENT

SL82 MESH TOP & BTM 50 COVER


/ /

/

/

/

LEGEND

/

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

100

/

/

/

/ /

0

/

/

/ /

RETAINING WALL CONTROL LINE

/

/

/ /

/ /

/

/

/

.0 40

/

/ /

/

PROPOSED RETAINING WALL

/

/

/

/ /

/

/

/ /

/ /

PROPOSED ROAD DESIGN

/ /

/ /

.76 9 5 CT 0 6

/ /

/ /

/

/

/ /

EXISTING SURVEY

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/ /

EXISTING BOUNDARY

/

/ /

/

/

/ /

/ /

/ /

/ /

PROPOSED BOUNDARY

/ / /

/

/ /

/ / / /

80

/

/ /

/ / /

/ /

90.08

/

/ /

/ /

0 7890.0

/ /

0 10

UIT

CIRC S R E G R RHEINBE

/ / /

/ /

/

/ /

/

/ /

/

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/ /

60

/ / / /

0 12

3

.2 27

/

/

/

/

/

/

/

/

/

/ /

1

/

/

/

/

/ /

/

/

/ /

/

/ /

/

/

/ /

/

/

/

/

/

/

/

TC

/

01 MW

0 0.0

/

/

/ /

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

14 0

/ /

/ / /

20

/

59

/ /

/

/ / /

/ /

160

40 TC 40 .

/

/ / / /

/

200 CT 201.5 3

/ / / / / / / / / / / / / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

320 TC 322.6 0

/

/

/

300

/

60

/

/

295.00

/

280

/

260

/

249.73

/

2 40

/

224.46

/

/

220

/

20

180

/

/

TC

/

7

.9 46

/

40

/

/ /

/ / /

/

/ /

/ /

/ / /

/ /

340

/

/

/

/ /

0.00

/ / /

/

/

/

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/

/

/

/

/ /

/

/

/

/

/

/

80

/

/

/ /

/

/ / /

/

/

360

/

/ / /

/ / /

/ / /

/ / /

/ / /

/

/ /

/ /

/ /

/

/ /

/ /

/ /

/

/ /

/

OHAN D / /

100

/ /

/

LIZ KERN

/ /

/

/ /

/

/ /

/ /

120

/ /

/ / /

/ / /

/ / / / /

/

/

/ / / /

/ /

/ / /

/ /

/ / /

/ /

/ /

/ /

/ /

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/ /

/ /

/ /

/

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/ /

/

/

/ /

/ / / / / / / / / / / / / / / / /

/

/ /

/ / / / / / /

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

RETAINING WALL PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C110-001

B

Mar 06, 2024 - 9:34am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-00.dwg

257.82

/ /

240

220

/

200

/

100% DETAIL DESIGN ISSUE FOR REVIEW

1cm at full size

/ /

/

Client

B

0

/

NOT FOR CONSTRUCTION North

-1

/ /

50 metres

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/ /

/

40

/ /

/

30

/

20

/ /

10

/ /

5

/ / /

180

/

0

160

/ /

/

140

/ /

/

CT 134.5

/ /

/

4

/

SANDSTONE BLOCK TIERED RETAINING WALL

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

RIVE


LEGEND 100

RETAINING WALL CONTROL LINE PROPOSED RETAINING WALL

0 102

PROPOSED ROAD DESIGN EXISTING SURVEY EXISTING BOUNDARY

12

0

PROPOSED BOUNDARY

0 104 /

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/ /

0 10

/ /

/

/ /

/

/

/

/

/ /

/

0 0.0

/ /

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/ /

/ /

/

/

/ /

/ /

/

/ /

0 MW

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/ /

/

.03 4 C8

/

/

/

/

/

/

/ /

/

/

/

/

/ /

/ /

/ /

/ / /

/

/

/

/ /

/

/

/

/ /

3

/

/ /

/

/

T

.7 44

/

/

2

/ / /

/

/

/

/

/ /

/

/

/ / /

/

/

RN KE

80

/

/

LIZ

0 106

/

/

/

/

/

/

40

/

/

/

/

OH

/

/

/

/

/

/

/

/ /

/

/

/

/

/ /

/

/

/

/

/ /

AN

/

/

/

/ /

20

/

REINFORCED CONCRETE BLOCK RETAINING WALL

/

/

/

/

/

/

/ /

/

/

/ /

/

/

DR

/

/

/

/

/

/

37.83

/ /

/ /

/ /

/

/

IVE

/

/

/ / /

/

/

/ /

60

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

Y A YW

/

/

/

/

/

/

REINFORCED CONCRETE BLOCK RETAINING WALL /

/ /

/

/ /

/ /

/

E

/ /

/

/

/

L AL

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

0 108

/

/

/ /

/

/ /

/

/ /

/

97 18. 20

/ / / /

/

/ /

/

/ /

/

40

/

/

/

/

/

/

/

/ /

/

/ /

/ /

/ /

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

03 W M

/

/

TC

/

/

1 109

/

/

.21

/

/

/

/

/

/

40

M CA

V N DE

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

1.24

/

00

6

/

/

49.

3.9

/

0

0.0

/ / / /

/ / / /

/ / /

1100

/

/ / / /

/ / / / / / /

/ /

/ / /

/ / / / /

/ / /

/ / / / /

/ / /

/ /

/ / /

/ / /

3 CT 1112.2 9 TC 1113.9

/ / / / / / /

/ /

/ / / /

/ / / / /

/

1120

/ / /

/ / / /

/ / / / / / / / / /

/

/ /

/

/ /

/ /

/ / /

/ / /

/ / /

/ /

/

/ /

/ / /

/ / /

/ /

/

RETAINING WALL PLAN MW02

4 114

.00

CT

93

5. 114

SCALE 1:250 SCALE 1:250 @ A1 SCALE 1:500 @ A3

0

2.5

5

10

15

20

SCALE 1:250

25 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

RETAINING WALL PLAN MW03

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

RETAINING WALL PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:250

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C110-002

B

Mar 06, 2024 - 9:34am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-00.dwg

/

0 114


72.13

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-10.dwg

MW01 PROFILE A1 Horizontal Scale 1 : 250 A1 Vertical scale 1 : 50

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

RETAINING WALLS ELEVATIONS (MW01) SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C110-101

B

Mar 06, 2024 - 9:34am

4.78 150

67.35

72.06 4.7 148

67.36

71.99 4.62 146

67.37

71.91 4.53 144

67.38

71.84 4.44 142

67.39

71.76 4.37 140

67.39

71.54 71.56 71.61 4.21 4.23 4.33 134 134.54 136

67.33 67.33 67.28

71.48 4.16 132

67.31

71.41 4.11 130

67.30

71.34 4.06 128

67.28

71.27 4.01 126

67.27

71.21 3.97 124

67.23

71.14 3.95 122

67.18

71.07 3.94 120

67.13

71.00 3.92 118

67.08

70.93 3.9 116

67.03

70.87 3.89 114

66.98

70.80 3.88 112

66.92

70.73 3.87 110

66.87

70.66 3.85 108

66.81

70.60 3.82 106

66.78

70.53 3.78 104

66.75

70.46 3.74 102

66.72

70.39 3.74 100

66.65

70.32 3.78 98

66.54

70.26 3.62 96

66.64

70.19 3.55 94

66.64

70.12 3.49 92

66.63

70.05 3.43 90

66.63

69.99 3.36 88

66.62

69.92 3.3 86

66.62

69.85 3.23 84

66.62

69.78 3.16 82

66.62

69.71 3.09 80

66.62

69.65 3.02 78

66.62

69.58 2.97 76

66.61

69.51 2.91 74

66.60

69.44 2.85 72

66.59

69.37 2.79 70

66.59

69.31 66.58 2.73

CHAINAGE

68

69.24 2.66 66

66.58

69.17 2.59 64

66.58

69.10 2.52 62

66.58

69.04 2.46 60

66.57

68.97 2.4 58

66.57

68.90 2.34 56

66.56

68.83 2.27 54

66.56

68.76 2.21 52

66.55

68.57 68.61 68.69 2.03 2.07 2.14 46.97 48 50

66.54 66.54 66.55

68.46 1.92 44

66.54

68.31 1.78 40

66.53

1.03 20

66.53

66.80

LEVEL DIFFERENCE

0.34

EXISTING SURFACE

0

66.46

DESIGN LEVELS

67.55

D

DATUM R.L 64.8


74.09 74.08

MW01 PROFILE A1 Horizontal Scale 1 : 250 A1 Vertical scale 1 : 50

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

RETAINING WALLS ELEVATIONS (MW01) SHEET 2 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C110-102

B

Mar 06, 2024 - 9:34am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-10.dwg

74.03 0.07 256 257.82

74.09 74.01 0.09 254

74.09 73.97 0.12 250

74.09 73.95 0.14 248

74.07 73.87 0.19 246

74.05 73.71 0.34 244

74.03 73.53 0.5 242

74.01 73.34 0.67 240

74.00 73.16 0.84 238

73.98 72.05 1.93 236

73.97 70.84 3.13 234

73.95 70.51 3.44 232

73.94 70.18 3.75 230

73.92 69.16 4.75 228

73.90 68.80 5.09 226

73.87 68.38 5.49 224

73.82 68.09 5.74 220

73.80 68.07 5.72 218

73.77 68.06 5.71 216

73.74 68.05 5.69 214

73.68 68.03 5.65 210

73.65 68.01 5.64 208

73.61 67.96 5.65 206

73.58 67.94 5.63 204

73.54 67.93 5.61 202

73.50 67.91 5.59 200

73.46 67.89 5.57 198

73.42 67.85 5.57 196

73.38 67.69 5.69 194

73.29 67.18 6.11 190

73.24 67.29 5.95 188

73.20 67.61 5.58 186

73.15 67.71 5.44 184

73.05 67.57 5.48 180

73.00 67.50 5.5 178

72.94 67.43 5.51 176

72.89 67.38 5.51 174

72.77 67.37 5.4 170

72.72 67.37 5.34 168

72.66 67.37 5.29 166

72.60 67.37 5.23 164

72.47 67.36 5.1 160

72.40 67.36 5.04 158

72.34 4.98 156

EXISTING SURFACE

67.36

4.92

CHAINAGE

154

72.27

4.78

67.35

LEVEL DIFFERENCE

150

DESIGN LEVELS

67.35

72.13

DATUM R.L 65.6


DATUM R.L 85.8

10

20

30

40

50 metres

SCALE 1:100 @ A1 SCALE 1:200 @ A3

0

1

2

4

6

8

10 metres

65.84 1.09 44.73

64.74

66.37 0.94

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-10.dwg

A1 Horizontal Scale 1 : 250 A1 Vertical scale 1 : 50

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

RETAINING WALLS ELEVATIONS (MW02) AND (MW03) SHEET 2 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C110-103

B

Mar 06, 2024 - 9:34am

A1 Horizontal Scale 1 : 250 A1 Vertical scale 1 : 50

5

40

65.43

MW03 PROFILE

0

66.61

66.74 66.73

MW02 PROFILE

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

37.83

66.17

65.93 65.92 0.81 0.82 18.97 20

0.66 3.96

66.20

66.83

0.65

CHAINAGE

66.85 66.84

LEVEL DIFFERENCE

0 1.24

0.07 44.83

90.48 90.48

90.20

0.17 40

90.46

90.27

89.84

0.59 -0

CHAINAGE

EXISTING SURFACE

0.02

90.01

88.34

LEVEL DIFFERENCE

DESIGN LEVELS

49 49.09

88.93

EXISTING SURFACE

DESIGN LEVELS

20

87.85

DATUM R.L 63.2


-10%

3000

-10%

STIFF NATURAL CLAY OR ENGINEERED FILL COMPACTED TO 98% STANDARD DRY DENSITY. 150kPa MINIMUM BEARING CAPACITY TO BE CONFIRMED BY GEOTECHNICAL ENGINEER

500 x 500 x 2000 LONG SANDSTONE BLOCKS TYPICAL

1.5V

1500 NOMINAL

REFER LANDSCAPE ARCHITECTS DETAILS FOR PLANTING

FREE DRAINING GRANULAR BACKFILL

2H

20 mm STEP TYP

200 MIN

-10%

STIFF NATURAL CLAY OR ENGINEERED FILL COMPACTED TO 98% STANDARD DRY DENSITY. 150kPa MINIMUM BEARING CAPACITY TO BE CONFIRMED BY GEOTECHNICAL ENGINEER

F.S.L. EXISTING MATERIAL

NO EXCAVATION/OTHER RETAINING WALL UNDER THIS LINE UNLESS DESIGNED ACCORDINGLY

1 2

TYPICAL TIERED SANDSTONE BLOCK RETAINING WALL (1500 MAX HEIGHT)

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-20.dwg

100mm FLEXIBLE AGG IN FILTER SOCK. 1% MINIMUM GRADE. OUTLET TO STORMWATER PIT OR DRAIN

FRO OF NT ZO INF LUE NE NC E

N.T.S.

SCALE 1:10 @ A1 SCALE 1:20 @ A3

0

100

200

400

600

800

1000mm

NOT FOR CONSTRUCTION

C COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd. Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

ACOR Consultants Pty Ltd

Project

LIZ KERNOHAN DRIVE UPGRADE BETWEEN CAMDEN VALLEY WAY T +61 2 4926 4811 AND LODGES ROAD

Level 1, 54 Union Street Cooks Hill, Newcastle NSW 2300

ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS

Drawing Title

RETAINING WALL NOTES AND DETAILS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

TRC

28.02.24

Designed

Project No.

Dwg. No.

Issue

NS210622

C110-201

SP

A1

Q.A. Check

Date

B

Mar 06, 2024 - 9:34am

A14 BIDIM GEOTEXTILE (OR APPROVED EQUIVALENT) TYP.


A -

NOM. (TO BE CONFIRMED ON SITE)

50 0

TO BE CONFIRMED ON SITE

50 0

OR Ø60 MW 0 P AT IPE ER LIN E4

1400

450Ø PIER TYP.

600

℄ PIER TO BE CONFIRMED ON SITE

ST

℄ PIER

600

PLAN RETAINING WALL No. STORMWATER LINE CROSSING SCALE 1:20

TOP OF WALL RL(TO BE CONFIRMED ON SITE)

TOP OF WALL

FOR TYPICAL RETAINING WALL DETAILS REFER DRG C110-201

℄ PIER

600

TOE OF WALL 6N12 TOP

6N12 TOP

1N16 'L' BAR CENTRAL TYP.

Ø450 PIER

PIERS TO BE FOUNDED INTO STIFF CLAY OF MIN. 250kPa BEARING CAPACITY (TYP.)

500

500

Ø450 PIER

Ø600 STORMWATER

FRONT ELEVATION RETAINING WALL No. STORMWATER LINE CROSSING SCALE 1:10 @ A1 SCALE 1:20 @ A3

0

100

200

400

600

800

100 COVER TYP.

300 MIN.

IL(TO BE CONFIRMED ON SITE)

R10-300 TIES IN PAIRS

105 APPROX.

6N16 BTM

300

RL -

R10-300 TIES IN PAIRS

6N16 BTM

1400

1N16 'L' BAR CENTRAL TYP. PIPE IL (VARIES)

Ø450 PIER BEYOND

Ø450 PIER

SECTION

A

SCALE 1:20

-

SCALE 1:20

1000mm

NOT FOR CONSTRUCTION

C COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd. Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-20.dwg

℄ PIER

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

ACOR Consultants Pty Ltd

Project

LIZ KERNOHAN DRIVE UPGRADE BETWEEN CAMDEN VALLEY WAY T +61 2 4926 4811 AND LODGES ROAD

Level 1, 54 Union Street Cooks Hill, Newcastle NSW 2300

ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS

Drawing Title

RETAINING WALL NOTES AND DETAILS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

TRC

28.02.24

Designed

Project No.

Dwg. No.

Issue

NS210622

C110-202

SP

A1

Q.A. Check

Date

B

Mar 06, 2024 - 9:34am

600

TOE OF WALL RL(TO BE CONFIRMED ON SITE)


PROVIDE 'L' BARS SAME SIZE AND SPACING AS PER HORIZONTAL REINFORCEMENT

190 BLOCKWORK

TOPSOIL AND TURF AS REQUIRED FGL

R20 - 600 LONG @ 400 - BITUMEN COAT ONE END NOTE: ALL DOWELS SAWCUT AND DE-BURRED

TOP OF WALL SETOUT

REFER TO CONTROL JOINT SEALANT DETAIL

N12 TOP COURSE

COURSE FREE DRAINING GRANULAR BACKFILL

PROVIDE 'L' BARS SAME SIZE AND SPACING AS PER HORIZONTAL REINFORCEMENT

190 BLOCK WALL

HEIGHT 'H' (MAX. 1200)

BACKFILL

150 WIDE FIBRE CEMENT SHEET FULL HEIGHT OF JOINT TAPED IN PLACE

TYPICAL CONTROL JOINT DETAIL

N12-400 STARTER BARS 450 LAP MIN.

30

100Ø SUBSOIL DRAIN WITH FILTER SOCK

SCALE 1:20

TOE OF WALL SETOUT

BASE WIDTH 'W'

REFER RETAINING WALL DETAILS

230

TYPICAL 190 BLOCKWORK CORNER DETAIL

SCALE 1:20

SCALE 1:20 450 MIN.

400 MAX.

350

CLEAN OUT BLOCK N12 EXTRA

TYPICAL 'T' INTERSECTION DETAIL

300 MIN.

100 MIN.

200

N12-400

REINFORCEMENT BARS

LEAVE CONCRETE SURFACE ROUGH UNDER BLOCKWORK

150kPa MIN. BEARING PRESSURE CAPACITY IN NATURAL GROUND

'Z' BARS CENTRAL AT 400 CENTRES TO MATCH FOOTING REINFORCEMENT

RETAINING WALL STEP DETAIL TYPICAL RETAINING WALL -- SECTION (MAX. HEIGHT 1200)

SCALE 1:20

3 No. 'Z' BARS TO MATCH FOOTING REINFORCEMENT 400 MAX.

GEOTEXTILE FABRIC TO BIDIM A14 OR EQUIV.

STOP ALL HORIZONTAL REINFORCEMENT AT JOINT

190 BLOCK WALL

REINFORCEMENT BARS

N12-400 65 COVER

30 BAR DIA LAP TYP.

CAPPING (IF REQUIRED)

30 BAR DIA LAP TYP.

FENCE (BY OTHERS)

3 No. 'Z' BARS TO MATCH FOOTING REINFORCEMENT

RETAINING WALL SHEAR KEY STEP DETAIL SCALE 1:20

SCALE 1:10

SECTION

-

SCALE 1:10

C---

NOTE: RETAINING WALL No. 1 SCHEDULE (MAX. HEIGHT 1200) WALL HEIGHT H (mm)

BASE WIDTH W (mm)

600

600

800

800

1000

900

1200

1000

REFER TO C-- FOR REINFORCED BLOCKWORK RETAINING WALL TYPICAL DETAILS

0

100

200

400

600

800

1000mm

NOT FOR CONSTRUCTION

C COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd. Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

ACOR Consultants Pty Ltd

Project

LIZ KERNOHAN DRIVE UPGRADE BETWEEN CAMDEN VALLEY WAY T +61 2 4926 4811 AND LODGES ROAD

Level 1, 54 Union Street Cooks Hill, Newcastle NSW 2300

ENGINEERS MANAGERS INFRASTRUCTURE PLANNERS DEVELOPMENT CONSULTANTS

Drawing Title

RETAINING WALL NOTES AND DETAILS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

AS SHOWN

TRC

28.02.24

Designed

Project No.

Dwg. No.

Issue

NS210622

C110-203

SP

A1

Q.A. Check

Date

B

Mar 06, 2024 - 9:34am

SCALE 1:10 @ A1 SCALE 1:20 @ A3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C110-20.dwg

NOTE: BLOCKWORK TO BE SPLITFACE AND COLOUR TO BE AS PER ARCHITECTS SPECIFICATIONS


LEGEND 0.000

ADJOINS SHEET 2

ROAD CONTROL LINE NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET

MCXX

ROAD CONTROL LABEL

BB

LINEMARKING TAG

NO

EXISTING SIGN TO BE REMOVED

STOPPING

NO

EXISTING SIGN TO BE REINSTATED

STOPPING

NO STOPPING

PROPOSED SIGN TO BE INSTALLED

UA1 ARROW RELOCATE EXISTING

KEEP LEFT

/

UA4 ARROW

/

/

NO

/

/

/

/

UA5 ARROW

/

/

/

C1 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

64.5

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

65.0

65.0

/

/

/

/

/

/

/

/

/

.0

65.0

TO

68.0 66.5 65 .5

67.5

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

64.5

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

67.0

/

68.5

/

CAMDEN VA LLEY WAY

67.0

65.5

.0

68

66.5

65.5

66. 0

67.5

65.5 /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

65.5 65.0

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

64.5

E4

65.5

E1

L1

65.5

65 .0

C3

EXISTING REMOVED

R4-1 (70)

REMOVE SIGN

C1

70

KEEP LEFT

300m ON LEFT

65.0

REINSTATE EXIST ING INFORMATION SIG N

L1

BB

EXI

STI

NG

RE

MO V

ED

NO PPI NG

/

64.5

/

.5 65

65.5

.0

66

MCB1

.5 65.0 65

/

67.0

65.5

66.5

STO

68.5

/

/

65

/

67.5

68.5

/

/

/

L3

/

/

/

.5

/

/

/

/

/

/

/

.0

/

/

/

/

/

/

66

65

C3 /

/

/

C1

BB

/

/

/

/

/

/

69.0

/

/

/

/

/

.0

69

66.5

R1-3

/

/

/

/

/

67.0

/

/

/

/

67 .5

STOPPING

W2-7

68 .0

/

68.5

UA3 ARROW

D EXISTING REMOVE

R1-3

STOPPING NO

EXISTING SIGN TO BE REINSTATED ON NEW POST

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-001

B

Mar 06, 2024 - 9:35am

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

EXISTIN

ADJOINS SHEET 2

G REM

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

OVED

EXISTIN G

REMOV ED

EXISTING REMOVED


LEGEND ADJOINS SHEET 3

ADJOINS SHEET 1

0.000

ROAD CONTROL LINE NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET

MCXX

ROAD CONTROL LABEL

BB

LINEMARKING TAG

NO STOPPING

RELOCATE EXISTING BUS STOP SIGN. BUS STOP LAYOUT AND SIGNAGE TO BE IN ACCORANCE WITH STATE TRANSIT AUTHORITY REQUIREMENTS. REFER NO TYPICAL BUS TO THE STATE TRANSIT AUTHORITY STOPPING STOP LAYOUT FOR DETAILS. NO STOPPING

EXISTING SIGN TO BE REMOVED

EXISTING SIGN TO BE REINSTATED

PROPOSED SIGN TO BE INSTALLED

EXISTING REMOVED NO STOPPING

L4 RELOCATE EXISTING

EXISTING FLOOD MARKER SIGN TO BE RELOCATED

STREET SIGNS TO BE REMOVED

E1

C3

EXISTING REMOVED

KEEP LEFT

R1-3

NO STOPPING

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

FROM

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

FROM

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

L3 EXISTING RELOCATED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

EXISTING

REMOVED

KEEP LEFT

C3

BB

VE G REMO EXISTIN

D

-3 R1

VED

NO G N PPI STO

E1

R

W2-7

/

KEEP LEFT

TING EXIS

NO STOPPING

VED EMO

EXISTING REMOVED

EM O

/

TO

L3

E1

E4

TB

GR

/

/

TO

/

TB

STI N

/

UA5 ARROW

CAMDEN VALLEY WAY

D4-1-1 (L)

L4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

L1 /

/

/

/

/

/

E4

/

TO

/

/

/

/

/

/

FR OM

/

R1-3

TB

E4

UA4 ARROW

BB

/

STOPPING

C3

MCB1

70

E4

UA3 ARROW

EXISTING RELOCATED

/

D EXISTING REMOVE

STO

EXI

UA1 ARROW

R1-3

NO PPI NG

/

/

/

/

/

E4 /

EXIST IN

G REIN

/

/

/

C3

FR OM

/

/

/

EXISTING REMOVED /

/ / / /

/

/

EXISTING

RELOCATED

/

/

G

/ / /

/ /

BB

/

/

/

/

C1

OXLEY RIVULET UPGRADE DESIGNED BY OTHERS

EXIST

/

/

/

L3

KEEP LEFT

ING R

/

/

EMOV ED

/

/

/

/

HILDE

OVED NO STOPP IN

G REM

E4 N STOP O PING

EXISTIN

TO

/

R STR

70

/

EET

MC03

STAT E

50

R1-3

/

/

EXISTING SHARED PATH SIGN REINSTATED

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

ADJOINS SHEET 3

EXIST

ING R

/ / / /

/ / /

/ /

C1

EXISTING SCHOOL ZONE / END SCHOOL ZONE SIGNAGE RETAINED

/

/

/

/

/

/

/

/

/

/

/

/

EMOV

ED

C3

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

BB

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-002

B

Mar 06, 2024 - 9:35am

/ /

/ / /

G

NO STOPP IN

EXISTIN

ADJOINS SHEET 1

W2-7

N STOP O PING

G REM

OVED

/

/

/

REMOVE EXISTING FLARED BB PAVEMENT MARKING


/ /

/

/ /

/

/

LEGEND

/

/

/

/

/ /

/

/

/

/ /

/

/

0.000

/

/

/

ADJOINS SHEET 5

/

ADJOINS SHEET 5

/

/ /

/

/ /

/

/

/

/

/

/

ADJOINS SHEET 4

/

ADJOINS SHEET 2

/

/

ROAD CONTROL LINE

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

REMOVE EXISTING T-INTERSECTION ADVANCED WARNING SIGN

NEW DESIGN

/

/

/

/

/

/

HERBERT RIVULET MCXX

ROAD CONTROL LABEL

BB

LINEMARKING TAG

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

C1

/

/

/

NO

/

EXISTING SIGN TO BE REMOVED

/

/

/

STOPPING

/

RELOCATE EXISTING BUS STOP SIGN. BUS STOP LAYOUT AND SIGNAGE TO BE IN ACCORANCE WITH STATE TRANSIT AUTHORITY REQUIREMENTS. REFER TO THE STATE TRANSIT AUTHORITY TYPICAL BUS STOP LAYOUT FOR DETAILS.

/

/

/ / / / /

/ / / / / /

/

/

/

/

/

/

/

/

TO

EXISTING SIGN TO BE REINSTATED

/

/

/

M

/

/

FRO

NO STOPPING

/

/

/

/

/

/

/

/

EXISTING (RELOCATE)

KIRKHAM LAN

/

E

/

/

/

/

/

/

/

/

/

/

/

/

/

70

/

/

C3

PROPOSED SIGN TO BE INSTALLED

/

/

/

/

/

/

/

/

/

/

/

/

/

NO STOPPING

/

/

/

/

/

/

/

EXISTING BLACK SPOT PROGRAM SIGN TO BE REMOVED.

/

/

/

C1

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

E1

/ / / / / / /

KEEP LEFT

/

/ / / / / / / / /

/ /

UA3 ARROW

/

/

/

W4-9

W8-15

EXISTING (REMOVE)

/

/

UA1 ARROW

EXISTING CURVE ADVISORY SIGNAGE TO BE RELOCATED

/

/

/

/

TF

/

/

/

/

/

L1

/

/ /

/ /

/ / /

UA4 ARROW

L1

/

/

/

/

/

C1

/

EXISTING (REMOVE)

/

/

MCB1

/

/

WAY

GIVE

C3

E4

MCB1

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

UA5 ARROW

PCW /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

TF

PCW

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

PCW

TF

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

CAMDEN VALLEY WAY /

/ /

CAMDEN VALLEY WAY

/

/

/

/

/

/

/

/

/

L1

EXISTING BI-DIRECTION SIGHT BOARD, AIRPORT DIRECTIONAL SIGN AND STREET NAME SIGNAGE TO BE REMOVED.

TF

EXISTING CAMDEN COUNCIL SIGN TO BE RELOCATED

C3

C1

E4

EXISTING "ROAD SUBJECT TO FLOODING" SIGN TO BE RELOCATED

KEEP LEFT

EXISTING "CAMDEN CHAMBER OF COMMERCE" SIGN TO BE REINSTATED

EXISTING (REMOVE)

E1

C1

RELOCATE EXISTING BUS STOP SIGN. BUS STOP LAYOUT AND SIGNAGE TO BE IN ACCORANCE WITH STATE TRANSIT AUTHORITY REQUIREMENTS. REFER TO THE STATE TRANSIT AUTHORITY TYPICAL BUS STOP LAYOUT FOR DETAILS.

C3

ADJOINS SHEET 4

ADJOINS SHEET 2

C1

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

LIZ KERNOHAN DRIVE

MCA1

ADJOINS SHEET 6

ADJOINS SHEET 6

C1 / /

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

/

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-003

B

Mar 06, 2024 - 9:35am

EXISTING (RELOCATE)

C3

70

L1

/

TO

FRO

M

/

/

/

/

PCW


LEGEND 0.000

ADJOINS SHEET 3

ROAD CONTROL LINE NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET

MCXX

ROAD CONTROL LABEL

BB

LINEMARKING TAG

NO

EXISTING SIGN TO BE REMOVED

STOPPING

NO

EXISTING SIGN TO BE REINSTATED

STOPPING

NO STOPPING

PROPOSED SIGN TO BE INSTALLED

G9-73

UA1 ARROW

E1 C3

UA3 ARROW

MCB1

UA4 ARROW / /

//

//

//

//

//

//

//

//

/ /

//

//

//

//

//

//

//

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

//

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

UA5 ARROW

Y

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

CAMDEN VALLEY WA

/

C3

C1

E1

BB

/ / /

/

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-004

B

Mar 06, 2024 - 9:35am

ADJOINS SHEET 3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

E4


LEGEND 0.000

ROAD CONTROL LINE NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET

MCXX

ROAD CONTROL LABEL

BB

LINEMARKING TAG

NO

EXISTING SIGN TO BE REMOVED

STOPPING

NO

EXISTING SIGN TO BE REINSTATED

STOPPING

/

NO STOPPING

/

/ /

/ /

/

/

/

PROPOSED SIGN TO BE INSTALLED

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/ /

/

/

UA1 ARROW

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

UA3 ARROW

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

BB

/

/

/

/

/

/

/

/

/

UA4 ARROW

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA2

/

/

/

UA5 ARROW

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

C3

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

E4

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / / /

/ / / /

E

/

/

/ /

/

/

E1

/

/

/

/

/

/

KIRKHAM LAN

/

/ / / / /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

REMOVE EXISTING SAFETY BARRIER.

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

C1

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/

/ /

/

/ /

/

/ /

/

/

/

/

/ /

/

/

/

/

/

/

/

/

ADJOINS SHEET 3

/

ADJOINS SHEET 3 /

/

/

/

/

/

/

/

/

/ /

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

/

/

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

/

50 metres

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-005

B

Mar 06, 2024 - 9:35am

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

/

E1


LEGEND 0.000

ADJOINS SHEET 3

ADJOINS SHEET 3

ROAD CONTROL LINE NEW DESIGN

C1 / /

/

EXISTING SURVEY

/

/ /

/

/ /

/

/

/

/

/

/

/ / /

/

/ /

/

/

/ /

LYNDSAY DYNAN 110 LODGES ROAD DESIGN

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/ /

/ /

/

/

/ /

/ /

/ /

/ /

HERBERT RIVULET

/ /

/ /

/ /

/ /

/ /

/ /

/

/

/

/

/

/

/ /

/

ROAD CONTROL LABEL

BB

LINEMARKING TAG

/

MCXX

/ /

/ /

/ /

/ /

/ /

/ /

/ /

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/ /

/

/

/ /

/ /

/

NO

/

/ /

/

/

/

C3

EXISTING SIGN TO BE REMOVED

STOPPING

/

/ /

/

/

/ /

/

/

/ /

/ / /

/ /

/

/ / /

/

/

/ /

/ /

/

NO

/

/ /

/

EXISTING SIGN TO BE REINSTATED

/

/

STOPPING

/

/ /

/

/

/ /

/

/

/ /

/ /

/ /

/ /

/

/

/ /

/

MCA1

/

/

/

/

NO STOPPING

/

/ /

/

-2

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

WA

/

/

/

VEY I G

/

/

/

/

R1

/

/

/

/

/

/ / /

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

P1

PROPOSED SIGN TO BE INSTALLED

/

/

/

/

/

/

/

UA1 ARROW

/

/ /

/

/

/ /

/ /

/

C3

/

/

/ /

LIZ

/

/

/

O RN KE

/

/

/

/

/

UA3 ARROW /

/

/

/

/

/

N HA

/

/ /

/

/

/

/ / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

BB

/

E IV DR

/

UA4 ARROW

/

/

/

/

/ /

/ /

UA5 ARROW

/ /

/ /

/

/

/ /

/

/

/ /

/ / /

/ / /

/ /

/ /

4 -61

/

/ / /

R2

/

TB

/

/

C3

/

_L

/

MC01

/ / / / / /

/

/ / /

E1

/ / / /

/ / / /

/ / /

/ / /

/ / /

/ / / / / / /

/ / /

/ /

/

/

/ /

/

/ /

/

/ /

/

/ /

/ /

/

/

/

/ /

/ /

/

/

/ / /

/

/

/

/ / /

/

/

/

/

/ / /

/

/ /

/ /

/

/

/ /

/

/ /

/

/ /

/

/

/

/ / / / / / / / /

/

/ / / / / / / / / / / / / / / / /

/

/ / / / / / / /

/ / /

/ /

/ / / / / / / / / /

/ /

/ /

/ / / / / /

/ /

P1

/ /

/ /

/ / / / /

/ / / /

P1

/ /

/ / /

/ / / / / / / / / / / / / / /

/

/ / /

ET HE

/ / /

7

/ /

/ / /

SS

/ / / /

IN DJO

/ / / /

/ / / / /

/

A

/ /

/ / / / / /

/ / / /

/ /

/ / / / / /

/ / / / /

/ /

E1

0

5

10

20

30

40

50 metres

Client North

-1

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Description 0

1cm at full size

7

NOT FOR CONSTRUCTION

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by:

Issue

ET

P1

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

NS JOI D A

E SH

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-006

B

Mar 06, 2024 - 9:35am

C3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

3(L) R2-


/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LEGEND

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

0.000

ROAD CONTROL LINE NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

ADJOINS SHEET 8

/

/

/

/

/

MC02

R2-3(L )

HERBERT RIVULET

C3

ROAD CONTROL LABEL

BB

LINEMARKING TAG

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

BB

MCXX

/

/

/

/

/

/

/

/

/

R1-2

NO

EXISTING SIGN TO BE REMOVED

STOPPING

W

/

/

/

/

/

/

/

/

/

/

/

E GIVAY

NO

/

/

/

/

TB

/

/

/

/

EXISTING SIGN TO BE REINSTATED

STOPPING

/

/

/

/

/

/

/

/

R2

/

/

/

/

-3(

/

/

/

/

NO STOPPING

/

/

/

/

/

/

/

L)

PROPOSED SIGN TO BE INSTALLED

/ / / / / / / / / / /

MCA1

/

C3

E1

R2-614 _L

LIZ

HA NO R KE

E RIV D N

/

/

/

/

/

/

/

UA1 ARROW

/

C3

/

/

/

/

/

/

/

/

UA3 ARROW /

/

UA4 ARROW

/

E1

/

/

/

/

/

E3

/

/

P1

/

/

/

/

/

/

/

/

/

R

/

/

C1

/

(L 2-3

)

/

/

/

UA5 ARROW

P1

/

/

/

/

/

/

/

/

/

/

C1 /

JO AD

/

/

/

/

C3

/

/

/

S IN

/

/ /

/

/

/

/

/

/

/

/

/

T6 EE SH

P1

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA1

/

C3

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ / /

/

/

/

/

/

/

/

/ /

/ /

/ / /

/ /

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/

/ /

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/ /

/

/ /

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ / /

/ /

/ /

/ /

/

/

/

/ /

/ /

/ /

/ /

/

/

/

/

/

/ /

/

/ / / /

/

/

/ /

/

/ /

/

/ /

/

ADJOINS SHEET 8

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

6 ET

E SH

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-007

B

Mar 06, 2024 - 9:35am

/

/

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

/

/

/

/

/

S IN

JO AD

SCALE 1:500 @ A1 SCALE 1:1000 @ A3


LEGEND ADJOINS SHEET 9

ADJOINS SHEET 7

0.000

ROAD CONTROL LINE NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET

MCXX

ROAD CONTROL LABEL

BB

LINEMARKING TAG

NO

EXISTING SIGN TO BE REMOVED

STOPPING

NO

EXISTING SIGN TO BE REINSTATED

STOPPING

NO STOPPING

PROPOSED SIGN TO BE INSTALLED

UA1 ARROW UA3 ARROW UA4 ARROW

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LIZ KERNOHAN DRIVE

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

MCA1

/

/

/

/

/

UA5 ARROW

/

/ / / /

/ /

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-008

B

Mar 06, 2024 - 9:35am

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

ADJOINS SHEET 9

ADJOINS SHEET 7

E3


LEGEND 0.000

ADJOINS SHEET 8

ROAD CONTROL LINE NEW DESIGN EXISTING SURVEY LYNDSAY DYNAN 110 LODGES ROAD DESIGN HERBERT RIVULET

MCXX

ROAD CONTROL LABEL

BB

LINEMARKING TAG

NO

EXISTING SIGN TO BE REMOVED

STOPPING

NO

EXISTING SIGN TO BE REINSTATED

STOPPING

NO STOPPING

PROPOSED SIGN TO BE INSTALLED

UA1 ARROW UA3 ARROW

/

/

UA4 ARROW

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

UA5 ARROW

/

/ /

/ /

/

/

/

/ /

/ / / /

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/ /

/ /

/

/

/ /

/

/

/

MCA1

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

/

LIZ KERNOHAN DRIVE

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

PAVEMENT MARKING AND SIGNPOSTING SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C111-009

B

Mar 06, 2024 - 9:35am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C111-00.dwg

E3


UTILITIES LEGEND ADJOINS SHEET 2

EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION) SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION)

CAMDEN VA L

LEY WAY

POWER POLE TO BE RELOCATED OUTSIDE CLEAR ZONE EXISTING OVERHEAD POWER AND POWER POLES TO BE REMOVED

GAS (ELECTRONIC LOCATION)

200

183.84 CTP 183.87

180

170.08

160

140

120

100

TC 84.03

80

60

40

20

0.00

MCB1

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED EXISTING STORMWATER PIPE, HEADWALLS AND PITS TO BE REMOVED

REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-001

B

Mar 06, 2024 - 9:35am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


UTILITIES LEGEND ADJOINS SHEET 3

ADJOINS SHEET 1

EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN

500

480

460

440

MCB1

420

400

380

360 CT 360.02

340

320

297.63 300

289.31

280

260

240

236.26

220 220.07 CT

EXISTING STORMWATER PIPE, HEADWALLS AND PITS TO BE REMOVED

SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION) GAS (ELECTRONIC LOCATION)

200

183.84 CTP 183.87

180

MCB1

TC 344.60

WATER MAIN (ELECTRONIC LOCATION)

CAMDEN VALLEY WAY

100 102.83

80

CT 71.44 EXISTING COMMUNICATIONS TO BE REMOVED

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED

APPROXIMATE LOCATION OF POWER POLE (NOT CONFIRMED BY SURVEY)

EXISTING STORMWATER PIPE, HEADWALLS AND PITS TO BE REMOVED

E

REMOVE EXISTING UTILITY

EXISTING OVERHEAD POWER, POWER POLES, STAY POLES, AND LIGHTING COLUMNS TO BE REMOVED

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

60

PROPOSED ELECTRICAL TO BE CONFIRMED TC 35. 97 40 0

5

10

20

ADJOINS SHEET 3

HILDE

ADJOINS SHEET 1

0.00

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-002

B

Mar 06, 2024 - 9:36am

20

R STR

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

EET

EXISTING OVERHEAD POWER, POWER POLES, STAY POLES, AND LIGHTING COLUMNS TO BE REMOVED


UTILITIES LEGEND ADJOINS SHEET 5

ADJOINS SHEET 5

EXISTING BOUNDARY ADJOINS SHEET 4

ADJOINS SHEET 2

160

180

PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL

MCA2

PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN

200

KIRKHAM LANE

PROPOSED COMMUNICATIONS PROPOSED GAS

EXISTING OVERHEAD POWER, POWER POLES, STAY POLES, AND LIGHTING COLUMNS TO BE REMOVED 220

EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN

800

MCB1

780

760

740

720

700

255.48 257.25 260

WATER MAIN (ELECTRONIC LOCATION)

680

671.96 CT 674.84

667.41

660

640

MCB1

620 621.54 623.99

600

580

540

520

500

560 TC 563.58

240

SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION) GAS (ELECTRONIC LOCATION)

TC 269.56 278.06 0.00 TC 0.05

CAMDEN VALLEY WAY

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

CAMDEN VALLEY WAY

20 EXISTING OVERHEAD POWER, POWER POLES, STAY POLES, AND LIGHTING COLUMNS TO BE REMOVED

EXISTING OVERHEAD POWER, POWER POLES, STAY POLES, AND LIGHTING COLUMNS TO BE REMOVED

E

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

40.00 EXISTING STORMWATER PIPE, HEADWALLS AND PITS TO BE REMOVED

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

PROPOSED ELECTRICAL TO BE CONFIRMED

CT 59.76 60

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

5

ADJOINS SHEET 6

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-003

B

Mar 06, 2024 - 9:36am

0

100

120

ADJOINS SHEET 6

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

80

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

MCA1


UTILITIES LEGEND ADJOINS SHEET 3

EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

WATER MAIN (ELECTRONIC LOCATION) SEWER MAIN (ELECTRONIC LOCATION)

945.79

940

920

900

880

TC 864.55

840

820

800

860

LIGHTING COLUMN

COMMUNICATIONS (ELECTRONIC LOCATION) GAS (ELECTRONIC LOCATION)

CAMDEN VALLEY WAY

EXISTING OVERHEAD POWER, POWER POLES, STAY POLES, AND LIGHTING COLUMNS TO BE REMOVED

MCB1

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-004

B

Mar 06, 2024 - 9:36am

ADJOINS SHEET 3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

0.00

LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION)

20

SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION)

MCA2 GAS (ELECTRONIC LOCATION)

40

KIRKHAM LANE

60

EXISTING OVERHEAD POWER, POWER POLES, STAY POLES, AND LIGHTING COLUMNS TO BE REMOVED 80

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

PROPOSED ELECTRICAL TO BE CONFIRMED

100

140

160 ADJOINS SHEET 3

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

ADJOINS SHEET 3

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-005

B

Mar 06, 2024 - 9:36am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

120


UTILITIES LEGEND ADJOINS SHEET 3

ADJOINS SHEET 3

EXISTING BOUNDARY

120

PROPOSED BOUNDARY PROPOSED UTILITIES

TC 127.23

PROPOSED STORMWATER

140

PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN

160

PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS

180

EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE

53

0 201. 0 2 T C

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

MCA1

OH RN

WATER MAIN (ELECTRONIC LOCATION)

90. 08

KE

40 C 40 T

LIZ

.59

60

EXISTING STORMWATER TO BE EXHUMED AND STORMWATER PITS TO 0 22 6 4 4. BE BLOCKED AT EACH END 22

8709.00

LIGHTING COLUMN

SEWER MAIN (ELECTRONIC LOCATION)

MC01 0 4

COMMUNICATIONS (ELECTRONIC LOCATION)

DR

20

AN

2

.73

E IV

9 24

S

GAS (ELECTRONIC LOCATION)

0.0

0

R E 0 RG T 26 E B UI N I E IRC H R C

EXISTING POWER TO BE DECOMMISSIONED EXISTING GAS TO BE DECOMMISSIONED

0

28

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

.00

5

29

EXISTING COMMUNICATIONS TO BE DECOMMISSIONED

0 30

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

.60 2 0 32 C 32 T

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

PROPOSED ELECTRICAL TO BE CONFIRMED 0

34

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

S 360 DJOIN A

7

380

400

T7

EE

H SS

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

N JOI D A

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 6 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-006

B

Mar 06, 2024 - 9:36am

ET

E SH


GRIMES AVENUE

UTILITIES LEGEND MC02 ADJOINS SHEET 8

EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER

57.75 40 41.00 CT 45.42

PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS

58

C2 6.

PROPOSED WATER MAIN

20

PROPOSED SEWER MAIN

.73

540

498 TC 500

.07

520

527.72

T

PROPOSED COMMUNICATIONS

CT

EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE

0

460

56 0

0.0

480

54 8

PROPOSED GAS

420 .36 3 2 4 CT

58 0

440

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION)

60 0

SEWER MAIN (ELECTRONIC LOCATION)

D

COMMUNICATIONS (ELECTRONIC LOCATION)

62

62 0

ER

GAS (ELECTRONIC LOCATION)

64

0

38

0

K Z I L

AN H NO

E RIV

4.0 0

0 40

MCA1

36 0

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

720

700

64

680

T6 EE SH

679.

S IN

66

0

JO AD

E

MCA1 EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

6 ET

E SH

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 7 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-007

B

Mar 06, 2024 - 9:36am

S IN

JO AD

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


UTILITIES LEGEND ADJOINS SHEET 9

ADJOINS SHEET 7

EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION) SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION)

1040

1020

1000

980

960

940

920

900 900.58

879.00 880

870.98

840

820

800

780

760

740

720

MCA1

860

GAS (ELECTRONIC LOCATION) E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED

LIZ KERNOHAN DRIVE

REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

0

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 8 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-008

B

Mar 06, 2024 - 9:36am

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

ADJOINS SHEET 9

ADJOINS SHEET 7

PROPOSED ELECTRICAL TO BE CONFIRMED


UTILITIES LEGEND ADJOINS SHEET 8

EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE

LODGES ROAD

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION) SEWER MAIN (ELECTRONIC LOCATION)

1184.83

1160

1180

GAS (ELECTRONIC LOCATION)

1140 1144.00 CT 1145.93

CT 1 TC 1 112.23 113.9 9 1120

1100

TC 1091.21

1040

1060

1080

COMMUNICATIONS (ELECTRONIC LOCATION)

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

MCA1

LIZ KERNOHAN DRIVE

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

06.03.24

MDM

TRC

A

DRAFT ISSUE FOR REVIEW

01.08.23

MDM

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

EXISTING UTILITIES PLAN SHEET 9 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-009

B

Mar 06, 2024 - 9:36am

ADJOINS SHEET 8

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-00.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


SUBSURFACE UTILITY INFORMATION LEGEND ADJOINS SHEET 2

QUALITY LEVEL 'B'. REFER TO AS5488-2013 QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN HORIZONTAL AND VERTICAL DATA INTERPRETED FROM WORKS AS CONSTRUCTED DATA. SYDNEY WATER CONTRACT No. 2014/0002143

Ø630mm PE100 S-RM

PROPOSED COMMUNICATIONS PROPOSED GAS

0

EXISTING UTILITIES TO REMAIN

183.84 CTP 183.87

200

180

170.08

250

160

140

120

200

100

TC 84.03

LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION)

100

50

80

150 60

40

20

100

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

0

0.00

50

EXISTING DRAINAGE

250

LEY WAY

200

CAMDEN VA L

150

Ø500mm DICL S-RM

SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION) GAS (ELECTRONIC LOCATION)

HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SEWER MAIN CONTROL PLANS SHEET 1 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-011

B

Mar 06, 2024 - 9:37am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-01.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


QUALITY LEVEL 'B'. REFER TO AS5488-2013

ADJOINS SHEET 3

ADJOINS SHEET 1

SUBSURFACE UTILITY INFORMATION LEGEND

QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN

HORIZONTAL AND VERTICAL DATA INTERPRETED FROM WORKS AS CONSTRUCTED DATA. SYDNEY WATER CONTRACT No. 2014/0002143

PROPOSED COMMUNICATIONS PROPOSED GAS

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

500

480

550 460

440

420

500

400

380

450 360 CT 360.02

TC 344.60

340

320

400

297.63 300

289.31

280

260 350

240

236.26

220 220.07 CT

EXISTING DRAINAGE

200

300

183.84 CTP 183.87

EXISTING UTILITIES TO REMAIN

LIGHTING COLUMN

300

CAMDEN VALLEY WAY

550

500

450

400

350

WATER MAIN (ELECTRONIC LOCATION)

100 102.83

180

Ø630mm PE100 S-RM

SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION)

Ø500mm DICL S-RM

GAS (ELECTRONIC LOCATION)

80 HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

CT 71.44

60 SEWER RISING MAIN NOT LOCATED

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED

TC 35. 97 40

REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-01.dwg

0.00 0

5

10

20

ADJOINS SHEET 3

HILDE

ADJOINS SHEET 1

R STR

20 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SEWER MAIN CONTROL PLANS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-012

B

Mar 06, 2024 - 9:37am

EET

PROPOSED ELECTRICAL TO BE CONFIRMED


SUBSURFACE UTILITY INFORMATION LEGEND ADJOINS SHEET 5

ADJOINS SHEET 5

180

QUALITY LEVEL 'B'. REFER TO AS5488-2013

ADJOINS SHEET 4

0 80

ADJOINS SHEET 2

160

HORIZONTAL AND VERTICAL DATA OF ROAD CROSSING PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES

200

HORIZONTAL AND VERTICAL DATA INTERPRETED FROM WORKS AS CONSTRUCTED DATA. SYDNEY WATER CONTRACT No. 2014/0002143

KIRKHAM LANE

PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS

220 PROPOSED WATER MAIN PROPOSED SEWER MAIN

750

PROPOSED COMMUNICATIONS

HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

EXISTING DRAINAGE

800

780

760

EXISTING UTILITIES TO REMAIN

740

720

700

255.48 257.25 260

PROPOSED GAS

680

667.41

660

640

620 621.54 623.99

700

600

580

650 560 TC 563.58

540

520

500

600

Ø630mm PE100 S-RM

671.96 CT 674.84

240

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN

CAMDEN VALLEY WAY

WATER MAIN (ELECTRONIC LOCATION)

900

850

800

278.06 0.00 TC 0.05

750

CAMDEN VALLEY WAY

SEWER MAIN (ELECTRONIC LOCATION)

Ø500mm DICL S-RM

COMMUNICATIONS (ELECTRONIC LOCATION)

100 102.44

600

650

700

TC 269.56

20

0

50

GAS (ELECTRONIC LOCATION) Ø375mm MSCL/DICL S-RM

SEWER RISING MAIN NOT LOCATED

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

40.00 SEWER RISING MAIN NOT LOCATED

CT 59.76 60

EXISTING UTILITIES TO BE REMOVED

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

80

100

120

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SEWER MAIN CONTROL PLANS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-013

B

Mar 06, 2024 - 9:37am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-01.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

REMOVE EXISTING UTILITY


SUBSURFACE UTILITY INFORMATION LEGEND ADJOINS SHEET 3

QUALITY LEVEL 'B'. REFER TO AS5488-2013 QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN

HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

920

900

880

840

820

EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

945.79

800

860

Ø500mm DICL S-RM

PROPOSED GAS

940

TC 864.55

PROPOSED COMMUNICATIONS

WATER MAIN (ELECTRONIC LOCATION)

1055.45

CAMDEN VALLEY WAY

1050

900

950

1000

LIGHTING COLUMN

SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION) GAS (ELECTRONIC LOCATION)

SEWER RISING MAIN NOT LOCATED

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SEWER MAIN CONTROL PLANS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-014

B

Mar 06, 2024 - 9:37am

ADJOINS SHEET 3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-01.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


SUBSURFACE UTILITY INFORMATION LEGEND QUALITY LEVEL 'B'. REFER TO AS5488-2013 QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN

0.00

PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN

20

EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN

40

WATER MAIN (ELECTRONIC LOCATION) SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION)

KIRKHAM LANE

60

GAS (ELECTRONIC LOCATION) E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

80

100

EXISTING UTILITIES TO BE REMOVED HORIZONTAL AND VERTICAL DATA OF ROAD CROSSING PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

120

REMOVE EXISTING UTILITY

HORIZONTAL AND VERTICAL DATA INTERPRETED FROM WORKS AS CONSTRUCTED DATA. SYDNEY WATER CONTRACT No. 2014/0002143

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

942.48

160 ADJOINS SHEET 3

80

0

ADJOINS SHEET 3

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

SEWER MAIN CONTROL PLANS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-015

B

Mar 06, 2024 - 9:37am

Ø630mm PE100 S-RM

900

850

140

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-01.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


SUBSURFACE UTILITY INFORMATION LEGEND ADJOINS SHEET 2

QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS

HORIZONTAL AND VERTICAL DATA INTERPRETED FROM SURVEY BY INFOCUS SURVEYORS. REF No. 13945-13096.03

EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

Ø450mm CICL W-POT

50

200

183.84 CTP 183.87

180

170.08

160

140

120

100

TC 84.03

80

WATER MAIN (ELECTRONIC LOCATION) SEWER MAIN (ELECTRONIC LOCATION)

200

CAMDEN VA

150

0

100

50

60

40

0

20

0.00

LIGHTING COLUMN

COMMUNICATIONS (ELECTRONIC LOCATION)

LLEY WAY

100

GAS (ELECTRONIC LOCATION)

250

200

150

Ø250mm DICL W-POT

HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING. REF No. NSW23-5077-US-01 R00

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

ISSUED FOR SYDNEY WATER COORDINATION

26.10.23

MDM

TRC

A

ISSUED FOR SYDNEY WATER COORDINATION

20.10.23

KB

TRC

Date

Drawn

Approved

Issue -1

Description 0

1cm at full size

10cm

20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

WATER MAIN CONTROL PLANS SHEET 1 Drawn

Date

Scale

KB

OCT 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

26.10.23

Dwg. No.

Issue

SK-C112-101

B

Mar 06, 2024 - 9:37am

ADJOINS SHEET 2

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-02.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


QUALITY LEVEL 'C'. REFER TO AS5488-2013

ADJOINS SHEET 3

ADJOINS SHEET 1

SUBSURFACE UTILITY INFORMATION LEGEND

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS

500

460

440

LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION)

500

420 450

400

480

Ø450mm CICL W-POT

380

360 CT 360.02

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

400

TC 344.60

320

340

EXISTING DRAINAGE

350

300

250

EXISTING UTILITIES TO REMAIN

297.63 300

289.31

280

260

240

236.26

220 220.07 CT

200

183.84 CTP 183.87

180

HORIZONTAL AND VERTICAL DATA INTERPRETED FROM SURVEY BY INFOCUS SURVEYORS. REF No. 13945-13096.03

SEWER MAIN (ELECTRONIC LOCATION)

CAMDEN VALLEY WAY

COMMUNICATIONS (ELECTRONIC LOCATION)

550

500

600

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

350

80

300

450

400

443.17

100 102.83 0

GAS (ELECTRONIC LOCATION)

Ø250mm DICL W-POT

CT 71.44 CHANGE IN PIPE MATERIAL AS PER BYDA INFORMATION FROM SYDNEY WATER

HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

EXISTING UTILITIES TO BE REMOVED

60

Ø250mm CICL W-POT

REMOVE EXISTING UTILITY HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING REF No. NSW23-5077-US-01 R00

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

TC 35. 97 40

50

ADJOINS SHEET 3

0.00

8 9. 47

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

WATER MAIN CONTROL PLANS SHEET 2 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-022

B

Mar 06, 2024 - 9:37am

Ø150mm CICL W-POT

HILDE

ADJOINS SHEET 1

R STR

20 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-02.dwg

EET

PROPOSED ELECTRICAL TO BE CONFIRMED


SUBSURFACE UTILITY INFORMATION LEGEND ADJOINS SHEET 5

ADJOINS SHEET 5 QUALITY LEVEL 'C'. REFER TO AS5488-2013

ADJOINS SHEET 4

ADJOINS SHEET 2

160

100 180

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY

Ø150mm DICL

PROPOSED UTILITIES PROPOSED STORMWATER

KIRKHAM LANE

200

220

PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS

EXISTING UTILITIES TO REMAIN

800

780

760

784.07

750

WATER MAIN (ELECTRONIC LOCATION)

CAMDEN VALLEY WAY 800

750

SEWER MAIN (ELECTRONIC LOCATION) COMMUNICATIONS (ELECTRONIC LOCATION)

900

850

0

700

OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES) LIGHTING COLUMN

CAMDEN VALLEY WAY 650

EXISTING DRAINAGE

TC 269.56 278.06 0.00 TC 0.05

600

740

720

700

680

671.96 CT 674.84

255.48 257.25 260

WATER MAIN LOCATION NOT RELIABLE

700

650

600

667.41

620 621.54 623.99

600

580

660

240

640

560 TC 563.58

540

520 550

PROPOSED LIGHTING COLUMNS

PROPOSED GAS

Ø450mm CICL W-POT

500

PROPOSED ELECTRICAL

PROPOSED WATER MAIN

50

HORIZONTAL AND VERTICAL DATA INTERPRETED FROM SURVEY BY INFOCUS SURVEYORS. REF No. 13945-13096.03

HORIZONTAL AND VERTICAL DATA INTERPRETED FROM SURVEY BY INFOCUS SURVEYORS. REF No. 13945-13096.03

GAS (ELECTRONIC LOCATION)

20 E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

Ø250mm CICL W-POT

WATER MAIN NOT LOCATED

40.00

HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING. REF No. NSW23-5077-US-01 R00

EXISTING UTILITIES TO BE REMOVED

CT 59.76 60

REMOVE EXISTING UTILITY

PROPOSED ELECTRICAL TO BE CONFIRMED

100

120

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

TC 127.23

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

WATER MAIN CONTROL PLANS SHEET 3 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-023

B

Mar 06, 2024 - 9:38am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-02.dwg

80

ADJOINS SHEET 4

ADJOINS SHEET 2

LIZ KERNOHAN DRIVE

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING


SUBSURFACE UTILITY INFORMATION LEGEND ADJOINS SHEET 3

QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS PROPOSED GAS EXISTING UTILITIES TO REMAIN EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

940

920

900

880

LIGHTING COLUMN

945.79

TC 864.55

840

820

800

860

WATER MAIN LOCATION NOT RELIABLE

WATER MAIN (ELECTRONIC LOCATION)

CAMDEN VALLEY WAY

COMMUNICATIONS (ELECTRONIC LOCATION)

1050

1000

950

GAS (ELECTRONIC LOCATION)

1069

.38

900

SEWER MAIN (ELECTRONIC LOCATION)

Ø250mm CICL W-POT

HORIZONTAL AND VERTICAL DATA PROVIDED BY UTILITY MAPPING. REF No. NSW23-5077-US-01 R00

E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

EXISTING UTILITIES TO BE REMOVED REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

WATER MAIN CONTROL PLANS SHEET 4 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-024

B

Mar 06, 2024 - 9:38am

ADJOINS SHEET 3

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-02.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


SUBSURFACE UTILITY INFORMATION LEGEND QUALITY LEVEL 'C'. REFER TO AS5488-2013

UTILITIES LEGEND EXISTING BOUNDARY PROPOSED BOUNDARY PROPOSED UTILITIES PROPOSED STORMWATER PROPOSED ELECTRICAL PROPOSED LIGHTING COLUMNS PROPOSED WATER MAIN PROPOSED SEWER MAIN PROPOSED COMMUNICATIONS

0.00

PROPOSED GAS EXISTING UTILITIES TO REMAIN

263.5

EXISTING DRAINAGE OVERHEAD ELECTRICAL (ASSUMED BETWEEN POLES)

20

250

LIGHTING COLUMN WATER MAIN (ELECTRONIC LOCATION)

40 HORIZONTAL AND VERTICAL DATA

SEWER MAIN (ELECTRONIC LOCATION)

INTERPRETED FROM SURVEY BY INFOCUS SURVEYORS. REF No. 13945-13096.03

KIRKHAM LANE

60

COMMUNICATIONS (ELECTRONIC LOCATION) GAS (ELECTRONIC LOCATION)

Ø150mm DICL W-POT E

DBYD

ELECTRICAL (DIGITISED)

W

DBYD

WATER MAIN (DIGITISED)

S

DBYD

SEWER MAIN (DIGITISED)

T

DBYD

COMMUNICATIONS (DIGITISED)

G

DBYD

GAS (DIGITISED)

200 80

EXISTING UTILITIES TO BE REMOVED

100

REMOVE EXISTING UTILITY

NOTE: ALL UTILITIES DEPTHS TO BE CONFIRMED BY POTHOLING

120

150

140

160 ADJOINS SHEET 3

ADJOINS SHEET 3

100 SCALE 1:500 @ A1 SCALE 1:1000 @ A3

0

5

10

20

30

40

50 metres

NOT FOR CONSTRUCTION Client

This drawing has been assigned an electronic code that signifies the drawing has been checked and approved by: North

B

100% DETAIL DESIGN ISSUE FOR REVIEW

A

NOT ISSUED

Issue -1

Description 0

1cm at full size

10cm

06.03.24

MDM

TRC

-

-

-

Date

Drawn

Approved 20cm

CAMDEN COUNCIL 70 CENTRAL AVENUE ORAN PARK, NSW 2570 PHONE : (02) 4654 7777

FAX : (02) 4954 7829

© COPYRIGHT of this design and plan is the property of ACOR Consultants Pty Ltd, ACN 079 306 246 ABN 40 079 306 246, all rights reserved. It must not be used, modified, reproduced or copied wholly or in part without written permission from ACOR Consultants Pty Ltd.

ACOR Consultants Pty Ltd

Project

CAMDEN VALLEY WAY UPGRADE BETWEEN HILDER STREET AND T +61 2 4926 4811 KIRKHAM LANE INCLUDING LIZ KERNOHAN DRIVE EXTENSION

The Forum, Level 1 Suite 1 240-244 Pacific Highway Charlestown NSW 2290

Drawing Title

WATER MAIN CONTROL PLANS SHEET 5 Drawn

Date

Scale

JER

MAR 2023

1:500

Designed

Project No.

SP

A1

NSW210622

Q.A. Check

Date

TRC

28.02.24

Dwg. No.

Issue

C112-025

B

Mar 06, 2024 - 9:38am

\\NEWPROJ1\Projects\NSW21\NSW210622\Drawings\CAD\CIV\Drawings\20 CVW and LKD Consolidated Plans\NSW210622-C112-02.dwg

PROPOSED ELECTRICAL TO BE CONFIRMED


Turn static files into dynamic content formats.

Create a flipbook