Rentable Area 1743 SF (R-3109)
Storefront Frontage 65’-8” (R-3109)
Ceiling Height 9’-0”
Tenant History
Naturalizer Shoes
Present Condition
Retail
General Layout
Open retail space with storefront windows
Storefront Construction
Anodized aluminum frames, clear glass
Ceiling Construction
Gypsum board and fabric wrapped panels, open in storage spaces
Special Features
Built-in shelving with under-shelf light
Approval Agencies
Boston Properties Design Review; San Francisco DBI & others.
Construction Type
• Structural concrete slab floor 12”-18” thick. Is not a post tensioned slab.
• Concrete deck above hard lid ceiling with concrete columns and beams.
HVAC Equipment
• 7.5 Tons of HVAC hanging from ceiling in back of space -
• FCU-1: Trane Model #BCHD090E1K0A4AM72
Hot / Chilled Water for HVAC
1 ½” Hot Water and 2” Chilled Water supply and return provided from main central system.
Service
• (1) Service feed to Panel “L” on Street level. Fed from A-level Electrical Panel APLF circuit breaker #10, located in room A22.
• 120/208V service 150 amp, 3ph, 4-wire
Sub-Panel(s)
• Street Level Back of House Storage Room:
• Panel “L” 120/208V, 3ph, 4-wire, 225 amp rated, 100 amp MCB. 42 circuit panel
Transformer N/A
Lighting
Track lighting and recessed cans throughout showroom. Track lighting and recessed down lights in display windows. Track lighting and recessed down lights on sales floor. Fluorescent lighting in storage room/back of house. Lighting controlled via timeclock.
DATA/COMMUNICATIONS
Telephone/Data
MPOE 3” Conduit stubbed to ceiling in Street level Storage Room from “A” level room A22.
PLUMBING Water Heater None
2” Cold Water Future
Waste
Tie into 4” sanitary sewer system below space
Waste Vent
Tie into 3” vent riser in adjacent space approximately 60 feet away