INT RENO STRATFORD

Page 1

Effective January 1, 2014 The following will be the State of Georgia's minimum Standard Construction Codes:

COMPUTER DRAWING TECHNICIAN

RESIDENTIAL SINGLE FAMILY OCCUPANCY CONSTRUCTION - WOOD FRAME INTERIOR RENOVATION AND EXTERIOR RENOVATIONEXISTING FOOT PRINT TO REMAIN-NO REMOVAL OR ADDITIONAL WALLS - NEW ROOFING ON HOUSE AND GARAGE.

ZONE 2 LOT:

RELEASED FOR CONSTRUCTION

INTERIOR SQUARE FOOTAGE: MAIN LEVEL 2584 SQ FT ATTIC LEVEL: 959 SQ FT, BASEMENT: 373 SQ FT. PORCHES: 875 SQ FT. ACRES:

CONTACT:

LAYOUT PAGE TABLE SHEET # DESCRIPTION 1 TITLE SHEET 2 SITE-SURVEY PLAN 3 EXISTING FOUNDATION PLAN BASMENT LEVEL 4 EXISTING FOUNDATION PLAN BASMENT LEVEL 5 EXISTING FLOOR PLAN MAIN LEVEL 6 EXISTING GARAGE FLOOR & ROOF PLANS 7 EXISTING FLOOR & ROOF PLANS ATTIC LEVEL 8 EXISTING ROOF PLAN 9 PROPOSED FLOOR PLAN BASEMENT LEVEL 10 PROPOSED FLOOR PLAN MAIN LEVEL 11 PROPOSED FLOOR PLAN MAIN LEVEL 12 PROPOSED FLOOR PLAN ATTIC LEVEL 13 PROPOSED WINDOW PLAN ATTIC LEVEL 14 PROPOSED ROOF PLAN MAIN LEVEL 15 PROPOSED ROOF PLAN ATTIC LEVEL 16 ELECTRICAL LIGHTING PLAN BASEMENT LEVEL 17 ELECTRICAL LIGHTING PLAN MAIN LEVEL 18 ELECTRICAL LIGHTING PLAN ATTIC LEVEL 19 PROPOSED ROOF PLAN MAIN LEVEL 20 PROPOSED ROOF PLAN ATTIC LEVEL

RESIDENTIAL SINGLE FAMILY OCCUPANCY CONSTRUCTION-WOOD FRAME INTERIOR RENOVATION AND EXTERIOR RENOVATIONEXISTING FOOT PRINT TO REMAIN INTERIOR SQUARE FOOTAGE: MAIN LEVEL 2584 SQ FT, ATTIC LEVEL: 959 SQ FT, BASEMENT 373 SQ FT. ZONE 2 LOT: ACRES:

• International Building Code, 2012 Edition, with Georgia Amendments (2015) • International Residential Code, 2012 Edition, with Georgia Amendments (2015) • International Fire Code, 2012 Edition, with Georgia Amendments (2013) • International Plumbing Code, 2012 Edition, with Georgia Amendments (2015) • International Mechanical Code, 2012 Edition, with Georgia Amendments (2012) • International Fuel Gas Code, 2012 Edition, with Georgia Amendments (2015) • National Electrical Code, 2011 Edition, with no Georgia Amendments • International Energy Conservation Code, 20011 Edition, with Georgia Supplements and Amendments (2011) (2012) • 2012 NFPA 101 – Life Safety Code with state Amendments (2013)

BY: J E NNY BUR GE R

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

11/23/2015

TITLE SHEET SCALE: 1/4" = 1' - 0"

SHEET: 1 OF 20


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.