BASEMENT RENO JOE

Page 1

BY: JENNY BURGER

INTERIOR RENOVATION & EXTERIOR ADDITION

PRELIMINARIES NOT FOR CONSTRUCTION

COMPUTER DRAWING TECHNICIAN

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT. SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

7/17/2019

TITLE SHEET SCALE: 1/4" = 1' - 0"

SHEET: 1 OF 5


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN

2852DH

5'-10"

19'

2840DH 2840DH

2840DH

17'-7"

12'-10"

5'-3"

2840DH

UNSPECIFIED 481 SQ FT

2680

2680

2040DH 2040DH

19'-5"

13'-9"

3280

APPROX. 106" TO BOTTOM OF DUCT. 20'-1"

PRELIMINARIES NOT FOR CONSTRUCTION

2040DH 2040DH

11'-9"

EXISTING BASEMENT FLOOR PLAN UNFINISHED CEILING HEIGHT117"-14" I JOIST ABOVE INTERIOR DOOR HEIGHTS: 96"

31'-10" 6'-5"

UNSPECIFIED

APPROX. 106" TO BOTTOM OF DUCT.

264 SQ FT

9'-2 1/2"

9'-2 1/2" UNSPECIFIED

UNSPECIFIED 290 SQ FT

3280

24'-1"

2840DH

66'-3"

480 SQ FT

3280

4180

5'-8 1/2" 4'-8"

1'-7"

4'-4"

1'-10"

3280

APPROX. 106" TO BOTTOM OF DUCT.

4'-3"

PIPE 110" TO BOTTOM

7' 13'-1"

5'

4'-8"

3'-5"

13'-1"

1'-6"

UNSPECIFIED

4'-2"

33'-6"

UP

16'-5"

17 STEPS 2680

3080

UNSPECIFIED

ELECTRICAL PANELS 3280

383 SQ FT

WH

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

20'-3"

20'-3"

3280

UNSPECIFIED 221 SQ FT

13'-8"

21'-5"

14'-1 1/2"

4'

16'-4"

2046DH 2046DH

20'-8"

283 SQ FT

430 SQ FT

WH

UTILITY

STORAGE

INTERIOR RENOVATION & EXTERIOR ADDITION

18'-5" 3280

17'-8 1/2"

5'-10"

1'-8"

3080

4'

2680

21'-10"

419 SQ FT

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

7/17/2019 LIVING AREA 3636 SQ FT

EXISTING FLOOR PLAN BASEMENT LOWER LEVEL SCALE: 1/4" = 1' - 0"

SHEET: 2 OF 5


BY: JENNY BURGER

2"

COMPUTER DRAWING TECHNICIAN

W1242L LCW2442L

3DB15

W2742

12'-10"

GYM

11'-3 1/4"

14980

334 SQ FT

3080

HALL 36 SQ FT

BAR

BEDROOM

6'-5"

TV

501 SQ FT

242 SQ FT

8"

APPROX. 106" TO BOTTOM OF DUCT.

4080

CL

198 SQ FT

5080

1'

W1242L

STAIRS 12'-1 1/2"

3080

58 SQ FT

8'-1 1/2"

7' MEDIA ROOM 695 SQ FT

13'-10 1/2"

4'-6" 22'-7"

3DB15

U152496L

7'-6"

2"

2DB331821 2DB331821 4'-4" 2DB331821 2DB331821 2DB331821

COUNTER DEPTH REFRIGERATOR

W382424

4'

14'-10 7/8"

13'-5"

E2

REMOVE WALL, INSTALL HEADER INTO CEILING.

PROJECTION SCREEN

EXISTING PIPE 110" TO BOTTOM

6'

31'-8"

2"

3080

3080

1'-6" 1'-6"

5 1/2"

WINE STORAGE

UP

5080

4'-6"

1'

1'-6"

BLOCKING

10080

54 SQ FT

7" TALL PLATFORM

U482196

4'

HALL

NICHE'

1'-6" 3'-5"

B36

SB3021 3DB1821 SB3021

13'-11"

4'-3"

2'

CONFIRM PLATFORM DEPTHS. CONFIRM CHAIR DIMENSIONS, IF THEY ARE RECLINING OR TO HAVE OTTOMANS, BEFORE CONSTRUCTING PLATFORMS.

7'

CONSTRUCT 7" TALL PERFORMANCE STAGE

REMOVE DOOR WAY FILL WALL

40.5" TALL KNEE WALLGLASS ABOVE

E1 18 RECYCLE 15" ICE

BATH 56 SQ FT

2'-2"

BLOCKING

17 SQ FT

2680

SHOWER

4'

5'-8 5/8"

4" CURB

DROP CEILING OVER SHOWER TO CONCEAL DUCT WORK.

10'-0 1/2"

5'-8 1/2" 4'-8"

BENCH

3080

BLOCKING

BLOCKING 3'

B15

18 SQ FT

8'-1"

28'-6 1/2"

2'

CLOSET

E3

1'

4'-5 1/2"

STEP

14" TALL PLATFORM

W1242L W301224

3'-6 1/2"

LCB36R 3DB15

6080

7'-0 1/2"

OTC332496

MICROWAVE & OVEN

DW

9'-5 1/2"

2'

31'-8"

LCW2442R W2442

40.5" KNEE WALL 1'-6"

INSTALL TRAY TO CONCEAL DUCT WORK.

REMOVE WALL

2840SC

2'-4"

U482196

NEW INTERIOR 2X4 DRYWALL WALL FURRED WALL

16'-5"

ELECTRICAL PANELS

WH

UNFINISHED

1'

INSTALL TRAY TO CONCEAL DUCT WORK.

1"

5670

268 SQ FT

420 SQ FT

UNFINISHED

WH

UTILITY

STORAGE

19'-9"

19'-9"

FILL WALL

15'-10" 13'

21'-5"

13'-7 1/2"

8"

8" 8"

6"

8"

OFFICE 237 SQ FT

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

INSTALL TRAY TO CONCEAL DUCT WORK.

8"

8"

6"

2046SC

2046SC

23'-11"

3080

INSTALL SHELVING IN STORAGE AREA.

INTERIOR RENOVATION & EXTERIOR ADDITION

NEW INTERIOR 2X4 DRYWALL WALL

TRAY 28" X 12"

24'-0 1/2" 3080

NEW INTERIOR 2X6 DRYWALL WALL

7' 5'-3 1/2"

20'-1"

17'-1 1/2"

13'-9"

4080

APPROX. 106" TO BOTTOM OF DUCT.

PRELIMINARIES NOT FOR CONSTRUCTION

DRYER

2840SC

5'-3"

INSTALL TRAY TO CONCEAL DUCT WORK.

SB27

2840SC

11'-2 3/4"

WASHER

EXISTING BASEMENT FLOOR PLAN UNFINISHED CEILING HEIGHT116"-14" I JOIST ABOVE INTERIOR DOOR HEIGHTS: 96" FLOORING: WOOD LOOK (CONFIRM: CERAMIC TILE OR LVT)

11'-10"

2852SC

7'

2840SC

2840SC

12" SOFFIT

LSB36

W2742

U442496

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

7/17/2019 LIVING AREA 3327 SQ FT

PROPOSED BASEMENT FLOOR PLAN SCALE: 1/4" = 1' - 0"

SHEET: 3 OF 5


BY: JENNY BURGER

PRELIMINARIES NOT FOR CONSTRUCTION

3' 4'-6"

4080

WINE

1'-6"

MICROWAVE

8'-8" 9'-8"

3'-6"

COMPUTER DRAWING TECHNICIAN

INTERIOR RENOVATION & EXTERIOR ADDITION

DW

3'-6"

ICE

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

3080

3'

4'-6"

1'-6"

8'-8"

9'-8"

3'-6"

WASTE

3'

10080

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

7/17/2019

PROPOSED BASEMENT BAR ELEVATIONS SCALE: 1/4" = 1' - 0"

SHEET: 4 OF 5


BY: JENNY BURGER

COMPUTER DRAWING TECHNICIAN ELECTRICAL SCHEDULE ATTACHED TO DESCRIPTION COMMENTS UNDER CABINET LIGHT CEILING 5" RECESSED CAN CEILING BAR PENDANT CEILING BED ROOM LIGHT CEILING WINE RM CHANDELIER CEILING EXHAUST CEILING HALL LIGHT CEILING NICHE' LIGHT CEILING OFFICE LIGHT CEILING RECESSED DOWN LIGHT 4 CEILING RECESSED VAPOR LIGHT CEILING STAGE LIGHT CEILING SMOKE DETECTOR FLOOR ADJUSTABLE HEIGHT LAMP FLOOR CLOTHES DRYER FLOOR CLOTHES WASHER FLOOR DISHWASHER FLOOR ELLINGTON FLOOR LAMP FLOOR GAS COOKTOP FLOOR HOOD W/ VENT FLOOR ICE MAKER FLOOR MICROWAVE FLOOR OVEN FLOOR REFRIGERATOR FLOOR SINGLE FLOOR RECEPTACLE, COVERED FLOOR WINE REFRIGERATOR WALL CABLE JACK WALL DUPLEX WALL GFCI WALL QUADRUPLEX WALL SINGLE POLE WALL SINGLE POLE SLIDING DIMMER WALL THEATER SCONCE WALL THREE WAY SLIDING DIMMER WALL VANITY SCONCE

GFCI

GFCI

R

R

R

R

R

CW

R

R

R

GFCI

R

R

CD

CONFIRM FLOOR RECEPTACLE LOCATIONS

DM

3DM

R

R

SD

R

R

PRELIMINARIES NOT FOR CONSTRUCTION

QTY 5 44 3 1 2 1 3 3 1 11 1 5 6 1 1 1 1 1 1 1 1 1 1 1 10 1 6 36 8 10 6 17 10 2 2

C

C

R

R C TV

DM DM

DM

R R

R

R

DM DM DM

SD

R4

R DW

M

R4

R

R

R

R4

R

O

DM DM R4

R4

R

R4

R R4

R4

GFCI

R4

C

R

R4

R H

DM DM

PROJECTION SCREEN

R4

CT

R4

GFCI

R

GFCI

SD

SD

R4

R4

R4

GFCI

UP R

R

R

R

R4

GFCI SD

R

R

R

R

R

DM

R

3DM

DM DM DM

R

ELECTRICAL PANELS DM DM

R

R

R4

CONFIRM CABLE JACK LOCATIONS.

R

WH

R4

WH

SD

R4

C

LIGHTS TO REMAIN THE SAME.

LIGHTS TO REMAIN THE SAME.

R

R

THE HOME OWNER, CONTRACTOR AND/OR BUILDER ARE RESPONSIBLE FOR REVIEWING AND ACCEPTING ALL DRAWINGS BEFORE CONSTRUCTION BEGINS. ALL DRAWINGS INCLUDING STRUCTURAL DRAWINGS MUST BE APPROVED/ STAMPED BY A CERTIFIED/ LICENSED ENGINEER AND/ OR ARCHITECT.

R

R

INTERIOR RENOVATION & EXTERIOR ADDITION

NUMBER E01 E02 E03 E04 E05 E06 E07 E08 E09 E10 E11 E12 E13 E14 E15 E16 E17 E18 E19 E20 E21 E22 E23 E24 E25 E26 E27 E28 E29 E30 E31 E32 E33 E34 E35

C

SHEET SIZE ANSI D (22" x 34") DATE ISSUED:

7/17/2019

PROPOSED BASEMENT ELECTRICAL LIGHTING PLAN SCALE: 1/4" = 1' - 0"

SHEET: 5 OF 5


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.