Condos - Revit Detail Sheet

Page 1

F 3 COAT STUCCO EXTERIOR FINISH; SCRATCH, BORWN AND FINISH, APPLY TO FACE OF APEX BLOCK

C

5" CONC. TOP SLAB OF INSUL-DECK FLOOR SYSTEM - SEE STRUCT.

WATER AND ICE GUARD

L

ST STUCCO REGLET OR DRIP SCREED, EQUIV.

PITCH STUCCO FINISH TOWARD ROOF - (TYP.)

RADIANT HEATING COILS

RADIANT HEATING COILS

Main Roof/Stairwell 60' - 0"

ROOFING MEMBRANE

12" INSUL-DECK FLOOR SYSTEM

PITCH STUCCO FINISH TOWARD ROOF -(TYP.)

10" APEX BLOCK WALL

10" 5"

BUILT-UP CANT STRIP

CABLE RAIL POST; EPOXY AND SET INTO CONC. PARAPET.

FILL CORES/CONC. GROUT. -SEE STRUCT. FOR REINFORCING

10"

J

ROOF SOIL (GROWING MEDIUM) GREEN ROOF SYSTEM. SKY GARDEN GR-SP; GR FILM SEAMS TAPED W/ ROOT GUARD

7" DIAM. METAL FLUE

REBAR @ BOTTOM OF CONC. BEAM - SEE STRUCT. W 14X STEEL BEAM (TYP); EXPOSED - SEE STRUCT.

10" DIAM. FLUE COVER 2" AIR SPACE

INSULATION POLYSTYRENE FOAM 3' - 8 1/2"

5/8" GYP. CEILING

4" MEATL STUD FRAMING

5/8" GYP. CEILING

ROOT BARRIER; ROOT GUARD 5/8" PLYWOOD SHEATHING

WATERPROOF MEMBRANE

ICE AND WATER GUARD

10" APEX BLOCK

TOP SLAB OF INSUL-DECK FLOOR; SLOPE 1/8"/FT ROOFING MEMBRANE

HORIZONTAL CABLE RAIL RAILING BY CABLE RAIL OR EQUIV.

ROOFING MEMBRANE OVER CONC. SLAB.

Second Floor 12' - 0"

CABLE RAIL RAILING; BY CABLE RAIL OR EQUIVALENT

CABLE RAIL POST; EPOXY AND SET INTO CONC. PARAPET.

ROOFING MEMBRANE

RAILLING POST; DOWEL INTO AOEX BLOCK PARAPET, GROUT AND EPOXY

1' - 4"

WESTILE PAVER ROOFING SYSTEM SEE DETAIL 7/A4.7

WESTILE PAVER ROOFING SYSTEM - SEE DEATIL 7/A4.7

3 COAT STUCCO EXTERIOR FINISH; SCRATCH, BROWN AND FINISH; WRAP OVER WALL; CONTINUOUS.

REBAR @ UNDERSIDE OF INSUL DECK CONC. BEAM -SEE STRUCT.

MODIFIED APEX BLOCK

12" INSUL-DECK FLOOR SYSTEM W/ 4-1/2" TOP CONC. SLAB; SLOPE TO DRAIN 1/8"/FT (TYP.) RAIDANT HEATING COILS

5/8" GYP. CEILING MODIFIED APEX BLOCK; THIS LOCATION

REBAR @ UNDERSIDE OF CONC. BEAM -SEE STRUCT.

5/8" GYP. CEILLING

FILL CORES W/ CONC. GROUT. -SEE STRUCT.

12 1/2" INSUL-DECK FLOOR SYSTEM - SEE STRUCT.

REBAR @ BOTOTM OF CONC. BEAM

5/8" GYP. CEILING

P.T. 2X10 FRAMING @ DOOR OPENING

REBAR @ BOTTOM OF CONC. BEAM - SEE STRUCT. W 14X STEEL BEAM (TYP); EXPOSED - SEE STRUCT.

5/8" GYP. CEILING

8 Wall @ Parapet and Cable Rail 1" = 1'-0"

REINFORCED CONC. LINTEL - SEE STRUCT.

Fifth Floor 48' - 0"

P.T. 4X12 CURB; WRAP W/ ROOFING MEMBRANE & WATERPROOF MEMBRANE BY G-SKY.

10" APEX BLOCK WALL

12 1/2" INSUL-DECK FLOOR SYSTEM

5" CONC. TOP SLAB OF INSUL-DECK FLOOR SYSTEM - SEE STRUCT.

RADIANT HEATING COILS

Second Floor 12' - 0"

REBAR @ UNDERSIDE OF INSUL-DECK CONC. BEAMS

F

Third Floor 24' - 0"

PITCH STUCCO FINISH TOWARD ROOF - (TYP.)

TOP CONC. SLAB OF INSUL-DECK FLOOR; SLOPE 1/8"/FT

Detail @ Steel Beam and Roof 1/2" = 1'-0"

2X10 BLOCKING

L

BUILT-UP CONC. CANT STRIP

4

3 COAT STUCCO EXTERIOR FINISH OVER METAL LATH; SCRATCH, BROWN AND FINISH

11 3/4"

K

WATER AND ICE GUARD

RADIANT HEATING COILS

WESITLE PAVER ROOFING SYSTEM - SEE DETAIL 7/A4.7

1' - 4"

Roof Parapet Detail 1/2" = 1'-0"

1' - 4"

10

I

6 Planter Detail @ Deck 1/2" = 1'-0"

3 Insul-Deck @ Steel Beam 1/2" = 1'-0"

ROOFING MEMBRANE O/ CONC. SLAB @ EXTERIOR DECK

J

TOP CONC. SLAB OF INSUL-DECK FLOOR; -SEE ROOF PLAN FOR SLOPES & DRAINAGE

6" 12" 4"

4" POURED CONC. APRON @ DRIVEWAY - SLOP TO RAIN TO STORM DRAINAGE @ STREET

#3 REBAR @ 16" O.C. E.W.

RADIANT HEATING COILS

ROOT BARRIER; ROOT GUARD WATER PROOF MEMBRANE

REBAR @ UNDERSIDE OF INSUL DECK CONC. BEAM - SEE STRUCT.

Fifth Floor 48' - 0"

DRIP SCREEN - ST STUCCO REGLET OR DRIP SCREEN EQUV.

APEX WALL SYSTEM 5/8" GYP. CEILING

5 1/2" MTL C CHANNEL SILL PLATE: THRU BOLT INTO CONC. SLAB (TYP.)

2 Fifth Floor Planter @ Ext. Wall 1/2" = 1'-0"

1' - 8"

4" METAL STUD FRAMING

VOLCLAY WATER PROOFING PANELS, SEE SHEET A4.14 FOR DETAILS; INSTALL PER MANUFACTURERS REQUIREMENTS

INSULATION POLYSTYRENE FOAM

3 COAT STUCCO EXTERIOR FINSIH; SCRATCH, BROWN AND FINISH

FILL CORES W/ CONC. GROUT -SEE STRUCT. FOR REINFORCING

10" APEX BLOCK WALL

STL REINFORCING -SEE STRUCT.

5/8" GYP. CEILING

2' - 6 3/4"

4" WASHED AND CLEANED GRAVEL

GREEN ROOF SYSTEM SKY GARDEN GR-SP; GR FILM SEAMS TAPED W/ ROOT GUARD

DRIP EDGE

WATER AND ICE GUARD; MOISTURE BARRIER (3) COAT STUCCO EXTERIOR FINISH OVER METAL LATH; SCRATCH, BROWN, FINISH

2X6 WD NAILER

5 1/2" MTL 'C' CHANNEL (TYP.)

Stairwell Roof 72' - 8"

5/8" PLYWOOD SHEATHING.

First Floor 0' - 0"

BUILT-UP CONC CANT. STRIP

FLASHING

Fourth Floor 36' - 0"

FLASHING

5/8" PLYWD SHEATHING

D

CLAY FLUE CAP.

1/2" EXPANSION JOINT

P.T. 4X12 ROOF SOIL (GROWING MEDIUM)

METAL FLUE CAP. CLAY FLUE TO EXTEND PAST CHIMNEY (CAP @ 12" DIM.)

12" INSUL-DECK FLOOR SYSTEM - SEE STRUCT.

REBAR @ UNDERSIDE OF INSUL-DECK CONC. BEAMS - SEE STRUCT.

Notes

G

GARAGE DOOR

5/8" GYP. CEILING

7" DIAM. FLUE; W/ 10" FLUE COVER

L

4" MEATL STUD BRACING @ 24" O.C.

5 1/2" METAL STUD WALL

EXISTING FILL

3 COAT STUCCO EXTERIOR FINISH; SCRATCH, BROWN AND FINISH

5" POURED CONC. -SEE STRUCT. FOR STL REINFORCING

1' - 4"

STL REINFORCING -SEE STRUCT. CONT. POURED CONC. FOOTING -SEE STRUCT.

Third Floor 24' - 0"

6"

1' - 0"

Basement Floor -12' - 0"

1' - 8"

FILTER BARRIER PER MANUFACTURER SPECIFICATIONS - TYP. MIN. 4" DIAM. FOUNDATION DRAIN

9 Wall Section @ South Wall 1/2" = 1'-0"

REBAR @ UNDERSIDE OF INSUL DECK CONC. BEAM - SEE STRUCT.

12" INSULDECK FLOOR SYSTEM 7" FLUE TO EXTEND THRU INSULDECK FLOOR; EXTEND TO WOOD BURNING STOVE UNIT. W/ 10" FLUE COVER

7 Detail @ Chimney Flue (Typ.) 1/2" = 1'-0"

6 7/8"

INSUL BLANKET W/ VAPOR BARRIER ONE SIDE - TYP. @ CONC. SLAB LOCATIONS

VOLCLAY WATER PROOFING PANELS, SEE SHEET A4.14 FOR DETAILS; INSTALL PER MANUFACTURERS REQUIREMENTS

5' POURD CONC. SLAB W/ STL REINFORCING -SEE STRUCT.

ROOFING MEMBRANE O/ CONC. SLAB @ EXTERIOR DECK

RADIANT HEATING COILS

TOP CONC. SLAB OF INSUL-DECK FLOOR; -SEE ROOF PLAN FOR SLOPES & DRAINAGE

4" WASHED & CLEANED GRAVEL

Main Roof/Stairwell 60' - 0"

APEX BLOCK WALL BEYOND

5 1/2" METAL STUD WALL

1/2" EXPANSION JOINT WESTILE PAVER ROOFING SYSTEM -SEE DETAIL 7/A4.7

2X10 NAILER

10" POURED IN PLACE CONC. WALL

INSUL BLANKET W/ VAPOR BARRIER ONE SIDE -TYP. @ CONC. SLAB LOCATIONS

STL REINFORCING -SEE STRUCT.

Date

05/07/20

Drawn by Checked by

BB PHJ

CONT. POURED CONC. FOOTING -SEE STRUCT.

6"

Basement Floor -12' - 0"

RADIANT HEATING COILS

12"

5 1/2" METAL STUD WALL

8' - 11"

Clerestory Roof 65' - 6"

RADIANT HEATING COILS

BRIAN BECHTOLD

HALL RESIDENCES

TOP CONC. SLAB OF INSUL-DECK TO SLOPE 1/8"/FT

5/8" GYP. CEILING REBAR @ UNDERSIDE OF INSUL DECK CONC. BEAM -SEE STRUCT.

20"

FILTER BARRIER PER MANUFACTURESERS SPECIFICATIONS -TYP.

Details

MIN. 4" DIA FOUNDATION DRAIN; DRAIN TO CISTERNS; EXCESS WATER TO DRAIN TO DAYLIGHT

-STL REINFORCING -SEE STRUCT.

5 Stairwell Roof Detail 1/2" = 1'-0"

1 Foundation Wall @ Footing 1/2" = 1'-0"

A 4.8