6800 REEDER MESA
4,301 SQFT - 40 ACRES - 5 BED - 6 BATH - $1,750,000 LISTED BY BOBBY BOE
Property Features Guide
6800 Reeder Mesa Road WIDE OPEN SPACES, GRAND MESA VIEWS & ENDLESS OPPORTUNITY
Set against the sweeping backdrop of the Grand Mesa, this remarkable farm and ranch property offers a rare combination of rugged beauty, wideopen land, and true western lifestyle. Walking distance to BLM land and minutes from National Forest, the grounds speak for themselves — crossfenced, irrigated pastures, a riding arena, round pen, and a livestock shelter create a turnkey setup for horses and cattle alike. The impressive barn is built for serious ranch work, with room for an RV, 4-horse trailer, flatbed, a dedicated shop, and a tack room. A separate ATV garage and oversized 3-car garage with pit and hoist round out the working infrastructure of this one-of-a-kind property. Located in hunting unit 41, just 20 minutes from Downtown Grand Junction — this is Western Colorado ranch living at its finest.
Managed Ranch Incentive
LISTING AGENT BOBBY BOE REALTOR ® ,ALC,Farm&Ranch Specialist
970.640.1903 970.242.3647 boebobby@rocketmail.com bobby.brayandcosearch.com
An experienced local rancher is available to lease and actively manage up to 35 of the property’s irrigated acres, allowing the new owner to focus on as little of 5 acres of direct involvement. The land stays productive, the pastures remain maintained and the buyer retains full ownership while scaling their involvement on their own timeline.
Included Incentives Keeps pasture maintained and in production Reduces the time and labor required from the owner Supports consistent land management and upkeep Allows flexibility to scale up operations over time Preserves the long-term value and usability of the property
BARN & HORSE STALL CONCEPTS
LISTING AGENT BOBBY BOE REALTOR ® ,ALC,Farm&Ranch Specialist
Barn improvement concepts focus on expanding equestrian functionality while maintaining operational workspace and storage.
970.640.1903 970.242.3647 boebobby@rocketmail.com bobby.brayandcosearch.com
Features include: Designed for horse stalls integrated into existing structure Heated and insulated work areas Dedicated tack room Overhead structural storage floor Conceptual drawings include: Barn stall floor plans Isometric model views
Storage floor and railing concepts Interior and exterior perspectives
These plans demonstrate how the existing barn can be adapted for expanded equestrian use while preserving flexibility for storage and ranch operations.
APPENDIX LISTING AGENT BOBBY BOE REALTOR ® ,ALC,Farm&Ranch Specialist
970.640.1903 970.242.3647 boebobby@rocketmail.com bobby.brayandcosearch.com
Materials included with this guide: Boiler Upgrade & Installation Included Farm & Ranch Equipment Building Site Plot Plans Irrigation Layout Drawings Barn Stall Floor Plans and Model Views Mechanical Specification Sheets
PROPERTY UPGRADE & ADDED VALUE GUIDE
Boiler System Upgrade and Installation Included Upgrades & Added Value for the Incoming Owner This property represents outstanding value at its listed price — and the current owners have gone above and beyond to ensure the next steward steps into a home that's truly ready to work for them from day one. The mechanical upgrades detailed below have been completed or purchased on behalf of the incoming buyer, adding nearly $19,000 in real, documented value.
Domestic Hot Water System — Fully Refreshed In December 2025, both boiler sidearms — the stainless steel domestic hot water tanks that supply the home — were replaced with brand-new units. This is the kind of foundational upgrade that gives a new owner genuine peace of mind, knowing the hot water system is fresh, efficient, and worry-free from the moment you take the keys. Hot Water Sidearm Replacement (December 2025)
$7,763.12
Boiler System — Comprehensive Maintenance Overhaul Completed alongside the new sidearms, a thorough mechanical servicing of the entire boiler system was performed. Every component was evaluated, and anything less than optimal was replaced or rebuilt: New main sidearm piping with dedicated hot and cold water shutoffs — a practical addition for garage use and a variety of ranch applications Two brand-new expansion tanks replacing the existing units New water pressure intake valve for reliable, consistent pressure regulation One new Grundfos circulating pump with shutoff valve, professionally installed One additional Grundfos pump kept on-site as a ready spare — exactly the kind of forward thinking that matters on a working property Automatic air remover fully rebuilt and restored to like-new condition Multiple system valves replaced throughout Valving re-wired and miscellaneous repairs completed Boiler System Maintenance & Upgrades
$1,231.73
Combined Boiler System Investment
$8,994.85
The Crown Jewel — A Brand-New High-Efficiency Boiler, Installed After Closing
Here's where this property truly shines. The existing Burnham boiler — 38 years old and still running — is being fully replaced with a state-of-the-art IBC VX199 High-Efficiency Boiler, featuring a 95% AFUE rating with MFZ technology. The unit has already been purchased and is on-site at the property. The sellers have made a thoughtful and generous decision: rather than installing the new boiler before the sale, they will complete the installation after closing, at their own expense. This means the new owner receives the full manufacturer's warranty from day one of ownership — a significant advantage that a pre-closing installation simply couldn't offer. Once a purchase contract is signed, a proposal from a licensed HVAC contractor will be obtained. That installation amount will be held in trust at the title company until the work is complete, giving the buyer full assurance the job gets done right. IBC VX199 High-Efficiency Boiler (purchased, on-site)
Estimated Professional Installation
$4,591.00
$4,000 – $5,000
Combined Boiler Unit + Installation Value
~$10,000.00
TOTAL DOCUMENTED MECHANICAL INVESTMENT
$18,994.85
That's nearly $19,000 in water heating and boiler infrastructure — much of it brand new, all of it directly benefiting the next owner. On a working ranch, reliable and efficient systems aren't a luxury — they're the backbone of daily life. This seller has done the hard work so you don't have to.
Prepared for prospective buyers | All values documented and verified
FARM AND RANCH EQUIPMENT INCLUSIONS
Included Equipment
Value
John Deere 2550 Tractor — 64HP, Four-Wheel Drive
$12,000
Three-Point Hitch Accessory Package (triple ball hitch + gooseneck)
$250
1,360' Fence Wire Roller Assembly (three-point hitch mount)
$125
John Deere MX7 7' Brush Hog Mower with drive shaft
$1,500
Danuser Commercial Post Hole Digger — 8" & 12" auger bits + hydraulic cylinder
$1,600
Custom Post Hole Digger Hanging/Storage Unit
$650
Rhino LR 6' Blade — adjustable wheels + removable spring tooth assembly
$1,150
Varner Heavy-Duty V-Ditcher — irrigation ditch maintenance
$1,500
Arena Rock Scraper — ranch made
$50
Two Light-Duty Chain Drags — four-wheeler pull-behind
$125
Heavy-Duty Chain Drag — tractor field use
$550
Spring Tooth Harrow — pull-behind field harrow
$1,200
70-Gallon Tank Sprayer — B&S engine, SS pump, hose reel + spreader bar
$1,200
TOTAL EQUIPMENT PACKAGE VALUE
$21,900
BUILDING SITE PLOT PLANS
IRRIGATION LAYOUT DRAWINGS
BARN STALL FLOOR PLANS AND MODEL VIEWS
BARN STALL FLOOR PLANS AND MODEL VIEWS
BARN STALL FLOOR PLANS AND MODEL VIEWS
BARN STALL FLOOR PLANS AND MODEL VIEWS
BARN STALL FLOOR PLANS AND MODEL VIEWS
BARN STALL FLOOR PLANS AND MODEL VIEWS
BARN STALL FLOOR PLANS AND MODEL VIEWS
VX 110 VX 150 VX 199
HIGH EFFICIENCY CONDENSING BOILERS
IBC Control at your fingertips
Standby
All VX™ Boilers use our V-10Touch Screen boilercontrol which features the latestin advance control technology and software. Easy to setup and monitor. Features include: Express
Setup, Diagnostics & Intuitive Alert System with plain English Warnings & Error Messages, no boiler has ever been easier to use!
Home B
A
Easy to use boiler control
G
E
D
H J
L I
C
F
Home Screen
Load Settings
Network Settings
Error Screen
K
Interior A) Intake Duct B) Exhaust Duct C) Heat Exchanger D) Ignition Module E) Fan F) Terminal Block Cover
G) Gas Valve H) Gas Line I) Supply Water Pipe J) Ignitor
K) V-10 Touch Screen L) Low Water Cutoff
A Unique Balance of
Performance, Efficiency and Value NEW V-10 CONTROL INTERFACE
MORE BUILT-IN FEATURES
• •Express •• setup - program your boiler in seconds Remote monitoring & diagnostics Easy USB programmability Instant visibility - Intuitive alert system with detailed error messages • Visible flame current data for troubleshooting • Simplified load combining • Cascade up to 4 units
MAXIMUM PERFORMANCE
Built-in 4 zone pump or valve control • In addition to the primary control – 5 pumps
• Replaces the need for external zone control • MFZ Technology: Patented moisture management system. Protects and ensures long life for all boiler components • Reverse flow detection • Built-in outdoor reset control of water temperature. • Built-in CSA/UL approved low water cut-off and manual reset high limit • Unmatched safety features • Connect your IBC Indirect Water Heater to the VX™ for all
THE LATEST IN HYDRONIC
• 95% A.F.U.E. Reduce operating costs and heat your home TECHNOLOGY faster State-of-the-art, fully automated, ASME, 439 grade, • SS firetube heat exchanger 100% factory tested Turndown ratio 6.5:1 means you have the power to heat your home during the coldest weather, yet reduce short cycling when • the weather is mild North American built. All VX models are • designed, engineered andassembledin British Columbia
•
•
your home heating needs EASY TO INSTALL AND SERVICE • Universal parts. With only one fan and one controller servicing all models just got a lot easier • PVC/CPVC/PPs approved • Longest combined vent lengths – Up to 200 ft with 2” and 480 ft 3” • Fuel conversion kits included in all models • Easy to inspect Heat exchanger featuring a condensate drainingsystemthat cleans asitheats
Dimensions
17.75”[451] 18.81” [478] 20.44” [520]
VX 110
28.13”[714] 28.19” [715] 28.19” [715]
VX 150
16.88”[429] 18.63” [473] 19.63” [498]
VX 199
PIPING CONNECTIONS
VX 110
DESCRIPTION A B
C D E F
Flue Outlet Combustion Air Inlet Return Water Outlet (tepid water) Supply Water Inlet (hot water) Condensate Outlet Gas Inlet
VX 150
VX199
3” Schedule 40 or 3” PPs (80mm) 35.33 (897) 2 (50) 3” Schedule 40 or 3” PPs (80mm) 35.33 (897) 2 (50) 1” NPT-M 1” NPT-M 3/4” Hose 1/2” NPT-F
CLEARANCE FROM BOILER CABINET Surface Front
Rear flueconnection Left side Right side Top Bottom
VENTING Sched.40; Rigid PPs 2” 3” 90° Vent elbow 90° Long sweep elbow 45° Elbow PPs 87-90° Elbows 2” SS Sidewall Terminal 3” SS Sidewall Terminal - exhaust vent 3” SS Sidewall Terminal - air intake Flexible PPs 3” Flexible
Minimum Distance from combustible surfaces
2” 0” 0” 1” 2” 0” (clearance for pipes)
Recommended distance for installation and service
24” 0” 4” (allow access to water connections) 4” (allow access to water connections) 6” (for vent connection) 12” (for condensate trap and piping)
MAXIMUM EQUIVALENT LENGTH
VX 110
100’ 240’ allow 8’ equivalent allow 5’ equivalent
allow 3’ equivalent use 8’ equivalent Noadditional allowance allow20’ equiv. of 3” sched. 40
VX 150 50’
170’ allow 8’ equivalent allow 5’ equivalent allow 3’ equivalent use 8’ equivalent Not allowed Not allowed
VX 199
Notallowed 150’
allow 8’equivalent allow 5’equivalent allow 3’equivalent use 8’equivalent Notallowed Notallowed
Noadditional allowances 45’ (max.) lineal x 1.2=equiv.
30’ (max.) linealx 3.33 = equiv.
Accessories
Floor Stand
Res. Parts Kit (VX+SL)
P-267
P-429
Condensate Tank 180-048
SPECIFICATIONS
VX 110
VX 150
VX 199
CSA Input (Natural Gas or Propane) - MBH
16.9 - 110
23 - 150
30.6 - 199 8.8
CSA Input (Natural Gas or Propane) - kW
5 - 32.2
6.7 - 44
- 58.3 29.2 -
16.2 - 101.5
22 - 138.5
183.7
4.74 - 29.8
6.5 - 40.6
53.8 95% 4 14
95%
95%
32° / 0° 122°
4
4
/ 50° 90% 34°
14
14
/ 1°
32° / 0°
32° / 0°
190° / 88°
122° / 50°
122° / 50°
40° / 22.2°
90%
90%
201° / 94° 90
34° / 1°
34° / 1°
88 / 39.9 3.51
190° / 88°
190° / 88°
/ 13.29 25 4
40° / 22.2°
50 8 30 0 -
201° / 94°
12,000 N/A
90
79
100’
67 / 30.4
78 / 35.4
1.88 / 7.12
2.7 / 10.56
14
19
2
3
50
50
8
8
30
30
0 - 12,000
0 - 12,000
100’
50’
CSA Output (Natural Gas or Propane) - MBH CSA Output (Natural Gas or Propane) - kW AFUE (Certification Pending) Min Gas Supply Pressure (Nat. Gas or Propane) – inch w.c. Max Gas Supply Pressure (Nat. Gas or Propane) – inch w.c. Ambient Temperature – Low (F/C) Ambient Temperature – High (F/C) Max relative humidity (non-condensing) Min water Temperature (F/C) Max water Temperature – (electronic high limit) (F/C) Max. ∆T - supply/return (electronic fence) (F/C) Max. Water Temperature Lockout Limit (F/C) Power (120Vac/60Hz) @ full fire - watts (without pumps) Weight (empty) – lbs/Kg Pressure Vessel water content – USG/Liters Max boiler flow rate - USgpm Min boiler flow rate - USgpm Max Operating Water Pressure - psig * Min Operating Water Pressure - psig Relief valve pressure - psig Approved installation altitude (Ft) Max equivalent vent length (each side)
Maxequivalentventlength (each side)
2”
3”
40° / 22.2° 201° / 94°
240’
8.6
-
H
170’
We are committed to deliveringa Greater Degree of Good acrosstheglobe-throughour intelligent products, responsibleprocessesandinspiredpeople.
sales@ibcboiler.com • www.ibcboiler.com
Toll Free: 1-844-HEATIBC/1-844-432-8422
®
All information contained in thisbrochureissubjecttochangewithoutnotice.Duetoclericalerror,regulation changeorproductdevelopmentpleaseconfirmallinformationwith IBC . 900-310 (R2)9 0050/2-93/2081 (9R 3)