VAC dynamic 1.6

TECHNICAL CHARACTERISTICS

Power (W)

Air-Flow (m3/h)

Waterlift (mm/H2O)

Airwatts

HEPA filter surface area (cm2)

Pro-Tecta filter surface area (cm2)

Bin capacity (L)

Noise level (dB)

Weight (kg)

High speed By-Pass peripheral motor

RECOMMENDATIONS FOR INSTALLATION

Dwelling size in m²

Furthest valve from the unit (lm)

Wall

130mm

Pallet size (12 pcs)

395 825 340 510 600 * ≤350 30 8 1600 190 3100 591 6000 1300 20 ≤60 15 380 520 350 680 100 130 39x46x89cm 80x138x193cm * Minimum space recommended to allow the dust container to be emptied comfortably.
Maximum number of inlet valves hanger detail 130mm
Box size

VAC dynamic 1.8

TECHNICAL CHARACTERISTICS

Power (W)

Air-Flow (m3/h)

Waterlift (mm/H2O)

Airwatts

HEPA filter surface area (cm2)

Pro-Tecta filter surface area (cm2)

Bin capacity (L)

Noise level (dB)

Weight (kg)

High speed By-Pass peripheral motor

RECOMMENDATIONS FOR INSTALLATION

Dwelling size in m²

Furthest valve from the unit (lm)

Pallet size (12 pcs)

Wall

hanger detail

620 600 780 * 380
≤500 50 12 1800 210 3300 643 6000 1300 28 ≤60 16 39x46x105cm 80x138x225cm 450 100 130 395 925 440 610 * Minimum space recommended to allow the dust container to be emptied comfortably.
Maximum number of inlet valves 130mm
130mm
Box size

VAC dynamic 2.4

TECHNICAL CHARACTERISTICS

Weight (kg)

2x High-speed through-flow motor

Dwelling size in m²

Furthest valve from the unit (lm) Maximum number of inlet valves

600 * 380
≤900 60 20 RECOMMENDATIONS FOR INSTALLATION 2400 (2x1200) 294 2800 835 6000 1300 28 ≤60 17 Power (W) Air-Flow (m3/h) Waterlift (mm/H2O) Airwatts
filter
area (cm2)
area (cm2)
* Minimum space recommended to allow the dust container to be emptied comfortably.
HEPA
surface
Pro-Tecta filter surface
Bin capacity (L) Noise level (dB)
Wall hanger detail 130mm 130mm 39x46x105cm Box size Pallet size (12 pcs) 80x138x225cm 395 925 440 610 620 780 710 450 100 130

VAC digital 1.6

TECHNICAL CHARACTERISTICS

Power (W)

Air-Flow (m3/h)

Waterlift (mm/H2O)

Airwatts

HEPA filter surface area (cm2)

Pro-Tecta filter surface area (cm2)

Bin capacity (L)

Noise level (dB)

Weight (kg)

High speed By-Pass peripheral motor

RECOMMENDATIONS FOR INSTALLATION

Dwelling size in m²

Furthest valve from the unit (lm)

Maximum number of inlet valves

Box size

Pallet size (12 pcs)

395 825 340 510 600 * ≤350 30 8 1600 190 3100 591 6000 1300 20 ≤60 15 380 520 350 680 100 130 39x46x89cm 80x138x193cm 1 2 3 4 5 6 1. Level power indicator 2. Hepa filter indicator 3. Electrical protection indicator 4. Total hours of use 5. Bin full indicator 6. Motor maintenance indicator * Minimum space recommended to allow the dust container to be emptied comfortably.
Wall hanger detail 130mm 130mm

VAC digital 1.8

TECHNICAL CHARACTERISTICS

Power (W) Air-Flow (m3/h)

Waterlift (mm/H2O)

Airwatts

HEPA filter surface area (cm2)

Pro-Tecta filter surface area (cm2)

Bin capacity (L)

Noise level (dB)

Weight (kg)

High speed By-Pass peripheral motor

RECOMMENDATIONS FOR INSTALLATION

Dwelling size in m²

Furthest valve from the unit (lm)

Maximum number of inlet valves

Box size

Pallet size (12 pcs)

≤500 50 12 1800 210 3300 643 6000 1300 28 ≤60 16 39x46x89cm 80x138x193cm 1 2 3 4 5 6 620 600 780 * 380 450 100 130 395 925 440 610 1. Level power indicator 2. Hepa filter indicator 3. Electrical protection indicator 4. Total hours of use 5. Bin full indicator 6. Motor maintenance indicator * Minimum space recommended to allow the dust container to be emptied comfortably.
Wall hanger detail 130mm 130mm

VAC digital 2.4

TECHNICAL CHARACTERISTICS

Power (W) Air-Flow (m3/h) Waterlift (mm/H2O)

Airwatts

HEPA filter surface area (cm2)

Pro-Tecta filter surface area (cm2)

Bin capacity (L)

Noise level (dB)

Weight (kg)

2x High-speed through-flow motor

RECOMMENDATIONS

Dwelling size in m²

FOR INSTALLATION

Furthest valve from the unit (lm)

Maximum number of inlet valves

600 * 380
39x46x105cm 80x138x225cm 395 925 440 610 620 780 710 450 100 130 1. Level power indicator 2. Hepa filter indicator 3. Electrical protection indicator 4. Total hours of use 5. Bin full indicator 6. Motor maintenance indicator 1 2 3 4 5 6 * Minimum space recommended to allow the dust container to be emptied comfortably.
Wall hanger detail 130mm 130mm Box size Pallet size (12 pcs) 2400 (2x1200) 294 2800 835 6000 1300 28 ≤60 17 ≤900 60 20

TECHNICAL CHARACTERISTICS

1500 190 3.000 550 5.000 28 ≤60 12 Power (W) Air-Flow (m3/h) Waterlift (mm/H2O) Airwatts HEPA CARTRIDGE filter surface area (cm2) Bin capacity (L) Noise level (dB) Weight (kg) High-speed through-flow motor Dwelling size in m² Furthest valve from the unit (lm) Maximum number of inlet valves
RECOMMENDATIONS FOR INSTALLATION ≤300 30 6-7 385 700 380 510 100

TECHNICAL CHARACTERISTICS

HEPA

High-speed

1500 190 3.000 550 5.000 20 ≤60 11
(W) Air-Flow (m3/h)
(mm/H2O)
Power
Waterlift
Airwatts
CARTRIDGE filter surface area (cm2)
capacity (L)
level (dB)
(kg)
Bin
Noise
Weight
through-flow motor Dwelling size in m²
valve from the unit (lm)
number of inlet valves
Furthest
Maximum
INSTALLATION ≤300 30 6-7
RECOMMENDATIONS FOR

Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.