Cooling Solutions with

EARTH Friendly energy Efficiency


FROM THE EDGE TO THE CLOUD Trust in Bentec Digital Solutions’ optimized solutions for connecting and protecting mission critical data center and networking infrastructure. The speed of changing technology creates significant new challenges for connecting and protecting data center and network infrastructure. Achievements of increased processing capacity, higher data latency and reduced operational costs are met with both expected and unexpected consequences. Multi-vendor systems create complexity. Busy connection pathways are stressed to their limits and new security threats emerge daily. Ever-expanding IT and communication requirements demand remote equipment solutions in places where they never existed. The highest amount of data and network availability is crucial in today’s connected world. Our broad portfolio provides design flexibility and protection.


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON Continuum of Cooling

We specialize in standard and customized air and liquid cooling solutions

05/30/2022


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON Aisle Containments 05/30/2022

4


COMPLETE

Cooling Solutions Data Centre Cooling

THE APEIRON CONTAINMENT SYSTEM LETS YOU CREATE CONTAINMENT INSTALLATIONS WITHOUT PROBLEMS. INCREASE EFFICIENCY AND CUT ENERGY COSTS • Consistent separation of cold and hot air. • Overpressure in the containment: Blow-in temperature of air conditioner is almost the same as the temperature in front of the servers. • No temperature layering in front of the 19" plane inside the containment. • No subcooling: possibilities to optimize temperature in data centers’. • Higher packing density per cabinet is possible with the same climate control elements. • Low investment with short ROI - no maintenance costs.


05/30/2022

6


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON Cold Aisle Containment Series Uncompromised Features 05/30/2022

7


COMPLETE

Cooling Solutions Data Centre Cooling DOORS • Standard solutions for 2000 mm and 2200 mm high cabinets. • Swing doors or • Sliding doors • Mechanical or • Electronic

High Roof Panels for Cold Air Circulation

Ceiling windows with electronic magnetic lock •

Automatic containment top covers open automatically in the event of fire so that the sprinkler systems installed above the containment top cover can put


COMPLETE

Cooling Solutions Data Centre Cooling

In normal operation, the top covers are kept closed by electromagnets and open when the floating contact of the fire detection system is opened.

Suitable for an aisle width of 1200 mm.

For cabinet widths of 600 or 800 mm.

Top cover 1.5mm frame, with safety glass 5 mm or / Acrylics.

With the universal top cover profile, the aisle height can be increased by 84 mm.

The top cover can be removed from the inside. When opened, the top cover provides access to lighting and sprinkler systems above the containment system for maintenance work.


COMPLETE

Cooling Solutions Data Centre Cooling Apeiron’s Additional Special Key Features

Two FA Biometric Lock Controller

LED Light inside

Electronic Auto Sliding Doors

05/30/2022

10


COMPLETE

Cooling Solutions Data Centre Cooling

OVERVIE W

APEIRON COLD AISLE CONTAINMENT • Modular standard components enable flexible adaptation to the requirements of your Data Centre. • Base system simple to combine and modify. • Minimal investment risk thanks to completely matched climate control system. • Short implementation time with minimum outlay.

05/30/2022

11


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON Cold Aisle Containment Package

05/30/2022

12


Item Number

Quantity

Description

1

6

LNH cabinets, powder coated, RAL 9004, with 100mm height rack base plinth.

2

24

Adjustable foot, Per cabinet with 4pcs.

3

12

4

6

Cable entry brushes to flat top cover left and right, size 170mm x 300mm. Front door, RAL 9004, with 150° hinges and perforation(Hexagonal hole), High density code lock, thickness 1.4mm.

5

6

Rear door, double door, RAL 9004, with 150° hinges and perforation(Hexagonal hole), High density code lock, thickness 1.4mm.

6

36

Horizontal Beam, RAL 9004, to accept 19" panel/slide mounts, thickness 1.5mm.

7

24

8

60

9

4

10

1

19" mounting rail, RAL 9004, thickness 2.0mm. Cable ring, rear of the cabinet. Left and right each size with 5pcs. Side panel, with round lock, for aisle closure, RAL 9004. Fully automatic doors, mechanical, Al extruded frame, 10 mm laminated safety glass, sliding mechanism and rail, fixing materials kit ,electric machinery and Access control.

11

1

12

3

13

12

Side-by-side for cabinets connection.

14

12

26 ways lockable C13 + 6 ways lockable C19 PDU, with 32A MCB, Hot swap A/V meter, 4mm2 x 5m power cable with 32A Industrial plug.

15

12

16

6

17

12

18

18

05/30/2022

Sliding doors, mechanical, Al extruded frame, 10 mm laminated safety glass, sliding mechanism and rail, fixing materials kit. Top windows, frame 1.5 mm, RAL 9004, 5 mm laminated safety glass, length 1200 mm, 2 cabinets with 1 window.

700mm Depth shelf, per cabinet with 2pcs. 2m copper earth bar. 200mm width vertical cable tray, per cabinet with 2pcs Blank Plate on the top of containment 13


05/30/2022

14


COMPLETE

Cooling Solutions Data Centre Cooling Apeiron’s Containment (Partial) Reference Projects List

Malaysia Data Centre

Singapore Data Centre 1 Singapore Data Centre 2 05/30/2022

15


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON Rack Based Cooling Solution Uncompromised Features 05/30/2022

16


COMPLETE

Cooling Solutions Data Centre Cooling In-Rack Cooling; High Efficiency for your Data Centre Our highly energy efficient air-to-water heat exchanger is integrated into an 800mm-wide rack, to the left or right of the 19” plane, and the cabinet offers full rack unit mounting space. The cooling solution is room independent and you can use it for various rack configurations.

https://bentec.digital/rack-based-cooling/

APEIRON Rack Based Cooling Solution 05/30/2022

Uncompromised Features

17


05/30/2022

18


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON In-Row Cooling Solution 05/30/2022

Uncompromised Features


COMPLETE

Cooling Solutions Data Centre Cooling

In-Row Coolers Applications

RackChiller In-Row Coolers (IRC) are designed to deliver localized / supplemental energy efficient cooling in data centers.

RackChiller IRC is a modular and scalable precision cooling solution that can replace or supplement traditional data centre cooling infrastructure. RackChiller may also be utilized as an integrated cooling solution for highdensity edge In-Row Cooling Solution APEIRON computing and Micro 05/30/2022 Uncompromised Features Data Center (MDC)

20


COMPLETE

Cooling Solutions Data Centre Cooling

In-Row Coolers Technical Drawing

APEIRON In-Row Cooling Solution 05/30/2022

Uncompromised Features

21


COMPLETE

Cooling Solutions Data Centre Cooling

In-Row Coolers Technical Drawing

APEIRON In-Row Cooling Solution 05/30/2022

Uncompromised Features

22


COMPLETE

Cooling Solutions Data Centre Cooling

In-Row Coolers Technical Specifications

https://bentec.digital/in-row-cooling/

APEIRON In-Row Cooling Solution 05/30/2022

Uncompromised Features

23


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON Rear Door Cooling Solution 05/30/2022

Uncompromised Features

24


COMPLETE

Cooling Solutions Data Centre Cooling

Rear Door Coolers Technical Specifications GENERAL SPECIFICATION Height

42U / 47U / 52U

Width

23.6 in / 600mm 31.5 in / 800mm

Depth

9.02 in / 229mm (passive)

Weight dry

13.0 in / 332mm (active)

Volume capacity

up to 2.6 gallons / 9.8 litres

Power Requirement

200V - 240V AC

Axial fans incorporating EC technology

0 fans (passive) / 4 fans (active)

Current Consumption

2.6 A rated, 8 A max

Air flow (100%)

4100 cfm / 200V - 24V AC

FANS

COOLING PERFORMANCE Maximum Duty (room 72-750F / 22 to

54kW

240C) Fluid flow

21.1 gpm / 4.8m3/hr

Pressure drop

14.5 psi / 100 kPA

Water supply

53.60F

/ 120C

https://bentec.digital/rear-door-cooling/

APEIRON Rear Door Cooling Solution 05/30/2022

Uncompromised Features

25


COMPLETE

Cooling Solutions Data Centre Cooling

Rear Door Coolers Technical Specifications

APEIRON Rear Door Cooling Solution 05/30/2022

Uncompromised Features

26


COMPLETE

Cooling Solutions Data Centre Cooling

Rear Door Coolers Technical Specifications

APEIRON Rear Door Cooling Solution 05/30/2022

Uncompromised Features

27


COMPLETE

Cooling Solutions Data Centre Cooling

APEIRON Cooling Solutions Decision Matrix Decision Matrix No Containment (old layout) not preferred. Increase liquid coolant temperatures Increase return air temperature -> reduce air flow

Parameter Rack thermal load

CRAC with Containment Rack Based In-Row <10kW <25kW < 25kW

Coolant supply temperature Air return temperature Temperature control Air flow per rack Aisle pressurization Coolant facility complexity Power Usage Effectiveness

n/a < 350C Room-based low low low < 1.7

<160C <450C Rack-based high medium high < 1.5

<200C < 450C Aisle-based medium medium medium <1.5

Rear Door Direct-to-chip < 55kw > 40 kW <200C <550C Rack-based high high high <1/2

> 200C high Rack-based low n/a very high <1.1

APEIRON Rear Door Cooling Solution 05/30/2022

Uncompromised Features

28


Powered by Intellect, Driven by Values


wered by Intellect, Driven by Valu