Benjamin Shih he/ him
Building Performance | Architectural Design benjiesyun0419@gmail.com +1 (404) 518-5977
With a background in architecture and building science, I bridge creative design with performance-driven analysis to create more sustainable buildings. My experience extends to Python programming and interdisciplinary research, including collaborating with computer science researchers to integrate machine learning-based microclimate predictions into building energy simulations, improving their accuracy and informing better design decisions.
SKILL Building Performance
OpenStudio IES-VE ClimateStudio Ladybug Tools
Computational & Design
Python Rhino Grasshopper Revit
LCA & Sustainability
One Click LCA BuildingEase Acelab LEED WELL
LEED AP BD+C | U.S. Green Building Council
WORK EXPERIENCE Devote Architecture Design Studio Architectural Intern
Kohn Pedersen Fox (KPF)
Environmental Performance Intern
Georgia Institute of Technology Graduate Research Assistant
New York, NY Oct 2026 - Present New York, NY Summer 2026 Atlanta, GA Fall 2025
EDUCATION Georgia Institute of Technology
Atlanta, GA 2024 - 2026
National Cheng Kung University
Tainan, Taiwan 2017 - 2022
M.S. High Performance Buildings
Bachelor of Architecture
AIA National Photography Competition Award | 2025 & 2026
Tower Urban Oasis
High-Performance Corporate Headquarters Organization
Kohn Pedersen Fox (KPF)
Period
Summer 2026
Location
Taipei, Taiwan
Category
Professional Work
Team
KPF Environmental Performance Team KPF Project Design Team
Role
Environmental Performance Intern
Program
Corporate Headquarters
Scope
Sustainability Analysis LEED Site Assessment Report Visualization
Tools
ClimateStudio, Ladybug Tools, SimScale Rhino, Adobe Indesign
Stormwater Analysis Site surfaces were mapped to size storage tanks and rain gardens for LEED storm retention targets.
Ecological Design An onsite carbon sequestration study compared tree carbon capture on the existing and proposed sites.
Performance Driven Green Tower Tower Urban Oasis reimagines the corporate headquarters as an urban ecosystem where architecture, landscape and sustainability work together. Working within the KPF Environmental Performance team, I supported the analyses behind its LEED Platinum, WELL Platinum, EEWH Diamond and net zero carbon targets. Using a shared project model, I translated complex geometry, multi level greenery and connected outdoor spaces into analysis ready models for water, solar exposure and natural ventilation simulations, from setup through report visualization. Diagrammatic reconstruction of the analysis workflow. Confidential project information has been omitted.
Stormwater Retention Areas 1000 m² Pervious Pavement 30 m² Impervious Pavement 3000 m² Landscape/ Vegetation 250 m² Grass/ Green Roof 150 m² Water Features 3500 m² Roof/ Terrace/ PV
Deciduous Large Tree Deciduous Medium Tree Deciduous Small Tree Evergreen Large Tree Evergreen Medium Tree Evergreen Small Tree
Thermal Environment Analysis Direct sun simulation shows most outdoor areas stay well shaded on the sunniest day, meeting WELL heat mitigation requirements.
Sun Hours (h) 10 5 0
Natural Ventilation Analysis Site wide CFD identified areas with too little or too much wind, guiding landscape buffers and terrace balustrades.
Wind Speed (m/s) 6 3 0
30 50 15 80 55 65
Al Maryah Island Hotel Performance-Driven Façade Design Organization
Kohn Pedersen Fox (KPF)
Period
Summer 2026
Location
Abu Dhabi, UAE
Category
Professional Work
Team
KPF Environmental Performance Team KPF Project Design Team
Role
Environmental Performance Intern
Program
Luxury Hospitality
Scope
Façade Analysis
Tools
ClimateStudio, Ladybug Tools
Performance Driven Façade Design
Selected Design Options
Selected options compare the trade-offs between view quality, solar radiation, and glare to identify a balanced façade configuration.
Option A More Open
86% View Quality
kWh/m².yr
57 Solar Radiation
22% Glare Concern
Avg % Unobstructed View
Peak Radiation
Glare Potential
0
0
ASE
100
65
Option B Balanced
Located in Abu Dhabi, the hotel explores the integration of architectural expression and environmental performance through a distinctive façade system. Façade studies evaluate how geometry and shading can reduce solar heat gain and improve thermal performance while maintaining outward views, informing a climate-responsive design for Abu Dhabi’s hot desert environment.
78% View Quality
kWh/m².yr
54 Solar Radiation
19% Glare Concern
Avg % Unobstructed View
Peak Radiation
Glare Potential
0
0
ASE
100
65
Option C More Shading
71% View Quality Optimized fin geometry integrates solar protection with outward views and a distinctive architectural expression.
kWh/m².yr
51 Solar Radiation
15% Glare Concern
Avg % Unobstructed View
Peak Radiation
Glare Potential
0
0
ASE
100
65
Vagelos Innovation Labs
All-Electric Academic Research Laboratory Organization
Kohn Pedersen Fox (KPF)
Period
Summer 2026
Location
New York, NY, USA
Category
Professional Work
Team
KPF Environmental Performance Team KPF Project Design Team
Role
Environmental Performance Intern
Program
Research Laboratory
Scope
3D Model Development Visualization
Tools
Rhino, Enscape, Adobe Photoshop
A Whole-Building Approach to Decarbonization Vagelos Innovation Laboratories is New York City’s first all-electric academic research laboratory, addressing the high energy demands of biomedical research through building electrification. Air-source heat pumps, energy recovery, and a high-performance façade reduce energy demand and eliminate on-site fossil fuel combustion, supporting Columbia University’s long-term net-zero goals.
Building Electrification & Energy Recovery
Reduced Energy Demand
All-electric systems to meet high laboratory loads
High-performance envelope and passive design strategies
All Electric High Performance Lab
All Electric High Performance Lab
Enhanced Air Quality Strategies
High Performance Facade Design
Bird Friendly Glazing
Electric ASHP Heating and Cooling
High-Efficiency Lab Systems
Advanced Heat Recovery Ventilation with MERV 14 Filtration
Enhanced Façade Insulation reduces Heat Loss and improves Energy Efficiency
Frit Treatment on Glass to Protect Birds
Integrated Sustainability Strategies A holistic approach to environmental Performance
Low Carbon Structural Design
Onsite Electric Vehicle Charging
Biophilic Design Integration
Heat Island Reduction
Optimized Structural Design reduces Concrete Demand & Low Carbon Concrete Selection
Basement EV Stations for Green Transit Methods
Ground Floor Planters Indoors and Outdoors, Extensive Green roof & Lush Green Wall in Collab Spaces
Green Roof and High Albedo Roof reduce Urban Heat Impact
Machine Learning Framework for Localized Climate Integration in BEM Period
Spring 2026
Location
Atlanta, Georgia, USA
Category
Master's Thesis Research
Advisors
Dr. Patrick Kastner, Tyrone Marshall, Dr. Johannes Milz
Team
Yupeng Tang, Ze-Yu Jiang
Role
Lead Researcher
Program
Campus Scale Microclimate Study
Scope
Localized EPW Workflow Development Building Energy Simulation Decarbonization Sensitivity Analysis
Tools
Python, ClimateStudio, Grasshopper
Microclimate Prediction Model Most building energy models use one weather file recorded at an airport to represent an entire city. Yet two buildings a few hundred meters apart can sit in very different thermal conditions. To capture this variation, the Sustainable Urban Systems Lab developed a machine learning model that combines a FusionLSTM network for time series forecasting with regression kriging for spatial interpolation. Trained on 16 campus weather stations together with geospatial, surface material and solar features, it predicts hourly temperature and humidity across 100,283 points on the Georgia Tech campus at about 4 m resolution.
Climate Data
Geospatial Data
Surface Material
Shadow Patterns
Sun Angle
14 Weather Stations
osmnx, USGS
OpenStreetMap
Pybshadow, Astral
Grasshopper
Temporal Fusion Transformer with LSTM-Attention Encoder (TFT-LAE)
Multimodel Development
Georgia Institute of Technology
Model Evaluation and Result
Organization
Data pre-processing
A Machine Learning Workflow from Campus Microclimate to Energy Model
Time Series Forecasting Variable Selection Network GRN Decoder
Time2Vec
Spatial Interpolation Kriging-based Model _Random Forest
LSTM + Attention Atlanta Weather Station Data
Combined Spatio-Temporal Forecast
Campus-level Microclimate Maps Generation
ML-predicted temperature across the Georgia Tech campus at 4 m resolution
ML-predicted humidity across the Georgia Tech campus at 4 m resolution
Baseline TMY EPW
Station-Based Observations
ML-Informed Hotspot Condition
ML-predicted campus microclimate
Annual Simulation Results across Weather Scenarios
HVAC Optimization Strategies
Envelope Retrofit Strategies
WWR Ratio Strategies
Adaptive Setpoint Control Strategies
Daylighting Control Strategies
ML-Informed EPW at Station Location
ML-Informed Cool-Spot Condition
Comparison of temperature profiles across the 5 scenarios Baseline TMY EPW
Station-Based Observations
ML-Informed Hotspot Condition
ML-Informed EPW at Station Location
ML-Informed Cool-Spot Condition
From Microclimate to Energy Model Building on this model, I developed a Python workflow that replaces the temperature and humidity in a standard TMY3 file with ML predictions at any campus location. All other weather variables stay unchanged, so any difference in results comes from local thermal conditions alone.
Campus-Scale Sensitivity and Impact Quantification
ML-Informed Weather Data
Campus Sensor Network
Energy Simulation
Shoebox Model
Energy Simulation
Quantifies bias introduced by city-scale weather assumptions
Shoebox Model
Energy Simulation
Identifies localized thermal variability beyond conventional monitoring
Shoebox Model Decarbonization Starategies
Comparison
HVAC Optimization Envelope Retrofit
% Energy Reduction
WWR Optimization Adjusting Setpoints Daylight Control
Peak Load Change Carbon Reduction
Simulation Setup A shoebox office was simulated in ClimateStudio under each scenario and tested against five decarbonization strategies, for 30 simulations in total.
EUI
CO2 Emissions
Cooling Load
Heating Load
Findings The five strategies responded in two ways. Chiller upgrades scaled with local cooling demand and saved 13% more energy at the hotspot than at the cool spot. Setpoint, daylighting, glazing and envelope measures saved nearly the same amount everywhere, so their relative value shrank on hotter sites. At the hotspot, chiller upgrades should come first, and equipment may need extra margin, since summer cooling ran 12% above TMY3. At the cool spot, the airport file remains adequate, and low cost operational measures can come before capital upgrades. Glazing and envelope measures performed the same everywhere, so they can be specified uniformly across campus.
From Past to Place
Baseline Model – sDG: 17%
Baseline Model – ASE (1000,250): 16.4%
Design Model – sDG: 0%
Design Model – ASE (1000,250): 3.3%
Revitalizing a Historic Library in Atlanta Organization
Georgia Institute of Technology
Period
Spring 2025
Location
Atlanta, Georgia, USA
Category
Academic Group Project
Instructor
Tyrone Marshall
Team
Yulim Oh, Spenser P Gruenenfelder
Role
Performance Simulation Lead
Program
Historic Library Adaptive Reuse
Scope
Building Performance Simulation Sustainability Strategies Development
Tools
ClimateStudio, Eddy 3D, Grasshopper
Performance Driven Adaptive Reuse This project transforms a historic library into a high performance building while preserving its cultural identity. Leading a team of two M.Arch students, I directed integrated simulations of energy, daylighting and airflow to guide each design move. The strategies combine an upgraded envelope, improved daylight access, passive ventilation and rooftop photovoltaics, reducing modeled annual energy use by up to 54% while keeping the character of the original building.
Daylighting Optimization Optimized glazing with varying visible light transmittance (VLT) to mitigate glare and excessive solar exposure while preserving the building’s historic architectural character. The strategy reduced sDG from 17% to 0% and ASE (1000,250) from 16.4% to 3.3%. sDG – Spatial Daylight Glare Probability ASE – Annual Sunlight Exposure
Wind Rose for the Summer Months
Outlet
Natural Ventilation Strategies Relocating the floor opening between the basement and ground floor frees usable space and turns a glare prone area into the main ventilation path. Under a prevailing south wind of 3.7 m/s, CFD results show air entering through the basement inlet, rising through the opening and crossing the ground floor before exiting at the roof outlet.
Opening
3.7 m/s 8 Intlet
6 4 2 0 unit: m/s
Energy Use Intensity [KWh / m2]
Cooling
Baseline
Iteration 1
CO2 Emissions by Fuel [t]
Electricity
Baseline
Iteration 1
Heating
Lighting
Equipment
Iteration 2
Iteration 3
Iteration 2
Iteration 3
Natural Gas
EUI Opmization Three iterations were tested against the baseline. A wider thermostat band reduced EUI from 129 to 88 kWh/m², and switching to an electric heat pump lowered it to 51 kWh/m² while eliminating natural gas. Natural ventilation brought the final EUI to 47 kWh/m², 36% of the baseline.
Dynamic Facade Design
Optimization for Daylighting and Natural Ventilation
Interior
90° Wide Open
Glazing Shading device
Organization
Georgia Institute of Technology
Period
Fall 2025
Location
Atlanta, Georgia, USA
Category
Academic Project
Role
Individual Project
Instructor
Hugo Sheward
Program
Building Facade Design
Scope
Daylight Simulation CFD Airflow Analysis
Tools
ClimateStudio, Autodesk CFD, Revit, Rhino
Interior
45° Partially Open
Glazing Shading device
Performance Driven Dynamic Facade
Interior
This project develops a dynamic, semi transparent facade that adjusts to daylight and solar exposure while giving the building a distinctive architectural expression. Site analysis, daylight simulation and CFD evaluation informed the design of adjustable shading panels, which balance natural light, solar protection and airflow to improve both occupant comfort and environmental performance.
Dynamic Shading device
Shading device
Glazing
Outside
0° Close
Glazing
Dynamic Shading device
Interior
Outside
Daylighting Analysis using ClimateStudio for Rhino 8
The severe indoor glare compromises the comfort of occupants. The sDG reaches 26.1%, with glare being particularly severe at noon.
Using ClimateStudio, the dynamic shading device was tested during winter afternoons, adjusting to 90 degrees (to allow sunlight) or 0 degrees (to block it). A reflective south-facing panel was added to redirect sunlight onto the ceiling for indoor diffusion while providing shade.
90° wide open to let sunlight in
Section
unit: m
DGP
DGP tables
Shading Device withReflective Material (South)
2000
3000
0 unit: cd/m²
0 unit: lux
False Color Renderings & Avg Lux
The evenly distributed daylight enhances both energy efficiency and occupant comfort. With an sDG of 0.9%, the design meets LEED v4 standards. 0° close to prevent glare
Dynamic Shading Device (North)
Plan
DGP
unit: m
Case I: An ambient wind speed of 6 m/s is considered
DGP tables
2000
3000
0 unit: cd/m²
0 unit: lux
False Color Renderings & Avg Lux
Case II: An ambient wind speed of 3 m/s is considered Wind Speed 20 m/s (66 feet/s)
increased wind speed observed
15 m/s (50 feet/s)
10 m/s (33 feet/s)
man (walking)
man (sitting)
A
increased wind speed observed
0 m/s (0 feet/s)
showing wind velocity distribution with the input wind speed 6 m/s (19.7 ft/s) A’
man (sitting)
AA’ CFD Simulation Section
man (sitting)
5 m/s (16 feet/s)
Wind Speed
increased wind speed observed
20 m/s (66 feet/s) 15 m/s (50 feet/s) 10 m/s (33 feet/s)
man (walking)
man (sitting)
5 m/s (16 feet/s)
CFD Simulation Floor Plan
CFD Simulation Floor Plan
BB’ CFD Simulation Section
showing wind velocity distribution with the input wind speed 6 m/s (19.7 ft/s)
showing wind velocity distribution with the input wind speed 3 m/s (10 ft/s)
showing wind velocity distribution with the input wind speed 3 m/s (10 ft/s)
0 m/s (0 feet/s)