With a background in architecture and building science, I bridge creative design with performance-driven analysis to create more sustainable buildings. My experience extends to Python programming and interdisciplinary research, including collaborating with computer science researchers to integrate machine learning-based microclimate predictions into building energy simulations, improving their accuracy and informing better design decisions.

SKILL Building Performance

OpenStudio IES-VE ClimateStudio Ladybug Tools

Computational & Design

Python Rhino Grasshopper Revit

LCA & Sustainability

One Click LCA BuildingEase Acelab LEED WELL

LEED AP BD+C | U.S. Green Building Council

WORK EXPERIENCE Devote Architecture Design Studio Architectural Intern

Kohn Pedersen Fox (KPF)

Environmental Performance Intern

Georgia Institute of Technology Graduate Research Assistant

New York, NY Oct 2026 - Present New York, NY Summer 2026 Atlanta, GA Fall 2025

EDUCATION Georgia Institute of Technology

Atlanta, GA 2024 - 2026

National Cheng Kung University

Tainan, Taiwan 2017 - 2022

M.S. High Performance Buildings

Bachelor of Architecture

AIA National Photography Competition Award | 2025 & 2026


Tower Urban Oasis

High-Performance Corporate Headquarters Organization

Kohn Pedersen Fox (KPF)

Period

Summer 2026

Location

Taipei, Taiwan

Category

Professional Work

Team

KPF Environmental Performance Team KPF Project Design Team

Role

Environmental Performance Intern

Program

Corporate Headquarters

Scope

Sustainability Analysis LEED Site Assessment Report Visualization

Tools

ClimateStudio, Ladybug Tools, SimScale Rhino, Adobe Indesign

Stormwater Analysis Site surfaces were mapped to size storage tanks and rain gardens for LEED storm retention targets.

Ecological Design An onsite carbon sequestration study compared tree carbon capture on the existing and proposed sites.

Performance Driven Green Tower Tower Urban Oasis reimagines the corporate headquarters as an urban ecosystem where architecture, landscape and sustainability work together. Working within the KPF Environmental Performance team, I supported the analyses behind its LEED Platinum, WELL Platinum, EEWH Diamond and net zero carbon targets. Using a shared project model, I translated complex geometry, multi level greenery and connected outdoor spaces into analysis ready models for water, solar exposure and natural ventilation simulations, from setup through report visualization. Diagrammatic reconstruction of the analysis workflow. Confidential project information has been omitted.

Stormwater Retention Areas 1000 m² Pervious Pavement 30 m² Impervious Pavement 3000 m² Landscape/ Vegetation 250 m² Grass/ Green Roof 150 m² Water Features 3500 m² Roof/ Terrace/ PV

Deciduous Large Tree Deciduous Medium Tree Deciduous Small Tree Evergreen Large Tree Evergreen Medium Tree Evergreen Small Tree

Thermal Environment Analysis Direct sun simulation shows most outdoor areas stay well shaded on the sunniest day, meeting WELL heat mitigation requirements.

Sun Hours (h) 10 5 0

Natural Ventilation Analysis Site wide CFD identified areas with too little or too much wind, guiding landscape buffers and terrace balustrades.

Wind Speed (m/s) 6 3 0

30 50 15 80 55 65


Al Maryah Island Hotel Performance-Driven Façade Design Organization

Kohn Pedersen Fox (KPF)

Period

Summer 2026

Location

Abu Dhabi, UAE

Category

Professional Work

Team

KPF Environmental Performance Team KPF Project Design Team

Role

Environmental Performance Intern

Program

Luxury Hospitality

Scope

Façade Analysis

Tools

ClimateStudio, Ladybug Tools

Performance Driven Façade Design

Selected Design Options

Selected options compare the trade-offs between view quality, solar radiation, and glare to identify a balanced façade configuration.

Option A More Open

86% View Quality

kWh/m².yr

57 Solar Radiation

22% Glare Concern

Avg % Unobstructed View

Peak Radiation

Glare Potential

0

0

ASE

100

65

Option B Balanced

Located in Abu Dhabi, the hotel explores the integration of architectural expression and environmental performance through a distinctive façade system. Façade studies evaluate how geometry and shading can reduce solar heat gain and improve thermal performance while maintaining outward views, informing a climate-responsive design for Abu Dhabi’s hot desert environment.

78% View Quality

kWh/m².yr

54 Solar Radiation

19% Glare Concern

Avg % Unobstructed View

Peak Radiation

Glare Potential

0

0

ASE

100

65

Option C More Shading

71% View Quality Optimized fin geometry integrates solar protection with outward views and a distinctive architectural expression.

kWh/m².yr

51 Solar Radiation

15% Glare Concern

Avg % Unobstructed View

Peak Radiation

Glare Potential

0

0

ASE

100

65


Vagelos Innovation Labs

All-Electric Academic Research Laboratory Organization

Kohn Pedersen Fox (KPF)

Period

Summer 2026

Location

New York, NY, USA

Category

Professional Work

Team

KPF Environmental Performance Team KPF Project Design Team

Role

Environmental Performance Intern

Program

Research Laboratory

Scope

3D Model Development Visualization

Tools

Rhino, Enscape, Adobe Photoshop

A Whole-Building Approach to Decarbonization Vagelos Innovation Laboratories is New York City’s first all-electric academic research laboratory, addressing the high energy demands of biomedical research through building electrification. Air-source heat pumps, energy recovery, and a high-performance façade reduce energy demand and eliminate on-site fossil fuel combustion, supporting Columbia University’s long-term net-zero goals.

Building Electrification & Energy Recovery

Reduced Energy Demand

All-electric systems to meet high laboratory loads

High-performance envelope and passive design strategies

All Electric High Performance Lab

All Electric High Performance Lab

Enhanced Air Quality Strategies

High Performance Facade Design

Bird Friendly Glazing

Electric ASHP Heating and Cooling

High-Efficiency Lab Systems

Advanced Heat Recovery Ventilation with MERV 14 Filtration

Enhanced Façade Insulation reduces Heat Loss and improves Energy Efficiency

Frit Treatment on Glass to Protect Birds

Integrated Sustainability Strategies A holistic approach to environmental Performance

Low Carbon Structural Design

Onsite Electric Vehicle Charging

Biophilic Design Integration

Heat Island Reduction

Optimized Structural Design reduces Concrete Demand & Low Carbon Concrete Selection

Basement EV Stations for Green Transit Methods

Ground Floor Planters Indoors and Outdoors, Extensive Green roof & Lush Green Wall in Collab Spaces

Green Roof and High Albedo Roof reduce Urban Heat Impact


Machine Learning Framework for Localized Climate Integration in BEM Period

Spring 2026

Location

Atlanta, Georgia, USA

Category

Master's Thesis Research

Advisors

Dr. Patrick Kastner, Tyrone Marshall, Dr. Johannes Milz

Team

Yupeng Tang, Ze-Yu Jiang

Role

Lead Researcher

Program

Campus Scale Microclimate Study

Scope

Localized EPW Workflow Development Building Energy Simulation Decarbonization Sensitivity Analysis

Tools

Python, ClimateStudio, Grasshopper

Microclimate Prediction Model Most building energy models use one weather file recorded at an airport to represent an entire city. Yet two buildings a few hundred meters apart can sit in very different thermal conditions. To capture this variation, the Sustainable Urban Systems Lab developed a machine learning model that combines a FusionLSTM network for time series forecasting with regression kriging for spatial interpolation. Trained on 16 campus weather stations together with geospatial, surface material and solar features, it predicts hourly temperature and humidity across 100,283 points on the Georgia Tech campus at about 4 m resolution.

Climate Data

Geospatial Data

Surface Material

Shadow Patterns

Sun Angle

14 Weather Stations

osmnx, USGS

OpenStreetMap

Pybshadow, Astral

Grasshopper

Temporal Fusion Transformer with LSTM-Attention Encoder (TFT-LAE)

Multimodel Development

Georgia Institute of Technology

Model Evaluation and Result

Organization

Data pre-processing

A Machine Learning Workflow from Campus Microclimate to Energy Model

Time Series Forecasting Variable Selection Network GRN Decoder

Time2Vec

Spatial Interpolation Kriging-based Model _Random Forest

LSTM + Attention Atlanta Weather Station Data

Combined Spatio-Temporal Forecast

Campus-level Microclimate Maps Generation

ML-predicted temperature across the Georgia Tech campus at 4 m resolution

ML-predicted humidity across the Georgia Tech campus at 4 m resolution


Baseline TMY EPW

Station-Based Observations

ML-Informed Hotspot Condition

ML-predicted campus microclimate

Annual Simulation Results across Weather Scenarios

HVAC Optimization Strategies

Envelope Retrofit Strategies

WWR Ratio Strategies

Adaptive Setpoint Control Strategies

Daylighting Control Strategies

ML-Informed EPW at Station Location

ML-Informed Cool-Spot Condition

Comparison of temperature profiles across the 5 scenarios Baseline TMY EPW

Station-Based Observations

ML-Informed Hotspot Condition

ML-Informed EPW at Station Location

ML-Informed Cool-Spot Condition

From Microclimate to Energy Model Building on this model, I developed a Python workflow that replaces the temperature and humidity in a standard TMY3 file with ML predictions at any campus location. All other weather variables stay unchanged, so any difference in results comes from local thermal conditions alone.

Campus-Scale Sensitivity and Impact Quantification

ML-Informed Weather Data

Campus Sensor Network

Energy Simulation

Shoebox Model

Energy Simulation

Quantifies bias introduced by city-scale weather assumptions

Shoebox Model

Energy Simulation

Identifies localized thermal variability beyond conventional monitoring

Shoebox Model Decarbonization Starategies

Comparison

HVAC Optimization Envelope Retrofit

% Energy Reduction

WWR Optimization Adjusting Setpoints Daylight Control

Peak Load Change Carbon Reduction

Simulation Setup A shoebox office was simulated in ClimateStudio under each scenario and tested against five decarbonization strategies, for 30 simulations in total.

EUI

CO2 Emissions

Cooling Load

Heating Load

Findings The five strategies responded in two ways. Chiller upgrades scaled with local cooling demand and saved 13% more energy at the hotspot than at the cool spot. Setpoint, daylighting, glazing and envelope measures saved nearly the same amount everywhere, so their relative value shrank on hotter sites. At the hotspot, chiller upgrades should come first, and equipment may need extra margin, since summer cooling ran 12% above TMY3. At the cool spot, the airport file remains adequate, and low cost operational measures can come before capital upgrades. Glazing and envelope measures performed the same everywhere, so they can be specified uniformly across campus.


From Past to Place

Baseline Model – sDG: 17%

Baseline Model – ASE (1000,250): 16.4%

Design Model – sDG: 0%

Design Model – ASE (1000,250): 3.3%

Revitalizing a Historic Library in Atlanta Organization

Georgia Institute of Technology

Period

Spring 2025

Location

Atlanta, Georgia, USA

Category

Academic Group Project

Instructor

Tyrone Marshall

Team

Yulim Oh, Spenser P Gruenenfelder

Role

Performance Simulation Lead

Program

Historic Library Adaptive Reuse

Scope

Building Performance Simulation Sustainability Strategies Development

Tools

ClimateStudio, Eddy 3D, Grasshopper

Performance Driven Adaptive Reuse This project transforms a historic library into a high performance building while preserving its cultural identity. Leading a team of two M.Arch students, I directed integrated simulations of energy, daylighting and airflow to guide each design move. The strategies combine an upgraded envelope, improved daylight access, passive ventilation and rooftop photovoltaics, reducing modeled annual energy use by up to 54% while keeping the character of the original building.

Daylighting Optimization Optimized glazing with varying visible light transmittance (VLT) to mitigate glare and excessive solar exposure while preserving the building’s historic architectural character. The strategy reduced sDG from 17% to 0% and ASE (1000,250) from 16.4% to 3.3%. sDG – Spatial Daylight Glare Probability ASE – Annual Sunlight Exposure


Wind Rose for the Summer Months

Outlet

Natural Ventilation Strategies Relocating the floor opening between the basement and ground floor frees usable space and turns a glare prone area into the main ventilation path. Under a prevailing south wind of 3.7 m/s, CFD results show air entering through the basement inlet, rising through the opening and crossing the ground floor before exiting at the roof outlet.

Opening

3.7 m/s 8 Intlet

6 4 2 0 unit: m/s

Energy Use Intensity [KWh / m2]

Cooling

Baseline

Iteration 1

CO2 Emissions by Fuel [t]

Electricity

Baseline

Iteration 1

Heating

Lighting

Equipment

Iteration 2

Iteration 3

Iteration 2

Iteration 3

Natural Gas

EUI Opmization Three iterations were tested against the baseline. A wider thermostat band reduced EUI from 129 to 88 kWh/m², and switching to an electric heat pump lowered it to 51 kWh/m² while eliminating natural gas. Natural ventilation brought the final EUI to 47 kWh/m², 36% of the baseline.


Dynamic Facade Design

Optimization for Daylighting and Natural Ventilation

Interior

90° Wide Open

Glazing Shading device

Organization

Georgia Institute of Technology

Period

Fall 2025

Location

Atlanta, Georgia, USA

Category

Academic Project

Role

Individual Project

Instructor

Hugo Sheward

Program

Building Facade Design

Scope

Daylight Simulation CFD Airflow Analysis

Tools

ClimateStudio, Autodesk CFD, Revit, Rhino

Interior

45° Partially Open

Glazing Shading device

Performance Driven Dynamic Facade

Interior

This project develops a dynamic, semi transparent facade that adjusts to daylight and solar exposure while giving the building a distinctive architectural expression. Site analysis, daylight simulation and CFD evaluation informed the design of adjustable shading panels, which balance natural light, solar protection and airflow to improve both occupant comfort and environmental performance.

Dynamic Shading device

Shading device

Glazing

Outside

0° Close

Glazing

Dynamic Shading device

Interior

Outside


Daylighting Analysis using ClimateStudio for Rhino 8

The severe indoor glare compromises the comfort of occupants. The sDG reaches 26.1%, with glare being particularly severe at noon.

Using ClimateStudio, the dynamic shading device was tested during winter afternoons, adjusting to 90 degrees (to allow sunlight) or 0 degrees (to block it). A reflective south-facing panel was added to redirect sunlight onto the ceiling for indoor diffusion while providing shade.

90° wide open to let sunlight in

Section

unit: m

DGP

DGP tables

Shading Device withReflective Material (South)

2000

3000

0 unit: cd/m²

0 unit: lux

False Color Renderings & Avg Lux

The evenly distributed daylight enhances both energy efficiency and occupant comfort. With an sDG of 0.9%, the design meets LEED v4 standards. 0° close to prevent glare

Dynamic Shading Device (North)

Plan

DGP

unit: m

Case I: An ambient wind speed of 6 m/s is considered

DGP tables

2000

3000

0 unit: cd/m²

0 unit: lux

False Color Renderings & Avg Lux

Case II: An ambient wind speed of 3 m/s is considered Wind Speed 20 m/s (66 feet/s)

increased wind speed observed

15 m/s (50 feet/s)

10 m/s (33 feet/s)

man (walking)

man (sitting)

A

increased wind speed observed

0 m/s (0 feet/s)

showing wind velocity distribution with the input wind speed 6 m/s (19.7 ft/s) A’

man (sitting)

AA’ CFD Simulation Section

man (sitting)

5 m/s (16 feet/s)

Wind Speed

increased wind speed observed

20 m/s (66 feet/s) 15 m/s (50 feet/s) 10 m/s (33 feet/s)

man (walking)

man (sitting)

5 m/s (16 feet/s)

CFD Simulation Floor Plan

CFD Simulation Floor Plan

BB’ CFD Simulation Section

showing wind velocity distribution with the input wind speed 6 m/s (19.7 ft/s)

showing wind velocity distribution with the input wind speed 3 m/s (10 ft/s)

showing wind velocity distribution with the input wind speed 3 m/s (10 ft/s)

0 m/s (0 feet/s)


Turn static files into dynamic content formats.

Create a flipbook
Portfolio_Benjamin Shih by archbenjaminshih - Issuu