INSTALLATION

G U I DE

EASY AS EMBASSY

WARNING The recommended humidity level for installing an Embassy ceiling is between 45 and 55%. The tiles and crossbars are covered with a polypropylene sheet. This material is not completely waterproof but still has good tolerance to moisture when installed in a damp room such as a well-ventilated bathroom, basement or cottage. It is not recommended to install the product in a place where it will be in direct contact with water. We recommend avoiding fitting the tiles too tightly along the walls to allow components to expand and contract with changes in humidity levels.

IMPORTANT

Before installing the tiles and crossbars, open the boxes and allow the material to acclimatize to the room at least 48 hours.

FOR ROOMS WITH A LARGE CEILING SPACE: The main crossbars should never be installed over a length greater than 10.668 m (35 ft). If the room is more than 10.668 m (35 ft) in length, then divide it into two or more sections. The Embassy ceiling system is not recommended for cathedral ceilings with a pitch of more than 4/12. If the joists are made of 2”x 10” or 2”x 8”, we recommend to install 5/8” wood strips, to avoid pendulum effect in the joists. This pendulum effect may produce a noise in the ceiling.

Only 4.445 cm (1-3/4’ ’ ) clearance between the structure and the ceiling.

A 1 2 3

42

8

8

10

48

7

½’’ 1½’’ 3’’

8

We recommend using #8, 1’’ wood screws, square or quadrex screwdriver bit, domed head.

7 9

9 4 5 8

11

18 30

72

17

84

16

19

96

21

102

15

4

17 5

7

54

18

18

7

6

13

19

10

10

16

20

13

12

19

21

16

15

23

84

22

19

17

26

102

23

23

20

29

120

24

24

32

126

5

21 6

9

54 72

24

9

17

42

27

13

12

21

66

28

17

14

26

84

03 INSTALL THE RAILS

B

36

26

7

ANCHOR

42

13 15

16

05

54

5 9 11

9 12 14

25

5

3 5

11 13

17

[ 13 4 17 8 2 ]

9

13 14 15

[ 11 8 1 ¼’’ 13 8 ]

18

9

16

26" c /c

36

7

8

26" c /c

30

6

7

9

Starting in the center of the room, install anchors (fig. A) on every joist using the installation template (fig. F). This template allows you to measure the correct distance between the anchors as well as between the anchors and the wall. Anchors must be installed on EVERY joist. Note that the distance between 2 anchors on the same main crossbar should never exceed 24". If the joists are not level, add furring strips to level.

12

24

7 8

5

6

11

02 INSTALL THE ANCHORS

3 5 6

5

5

12

Locate the center of the ceiling space to be covered and use a chalk line to draw the room’s center line. Note that the main crossbars (fig. D) must be installed in the opposite direction of the joists. Next, visualize how the tiles will be placed (fig. E) by arranging them on the floor, leaving about a 2" space between each tile. Determine if you have to install the ceiling beginning with centered tiles or centered crossbars

2 3 4

4

6

10

01 PRERARE THE INSTALLATION

2 3 4

RAILS & ANCHORS

04

SECONDARY CROSSBAR

03

MAIN CROSSBAR

02

RESULT GRID

01

TILES 2’X4’

INSTALLATION GUIDE

Now slide the rails (fig. B) into the main crossbar (fig. D). You will need 6 rails per full length main crossbar. Because the rails have to support the weight of the ceiling, it is important to always use the required number of rails and not cut them.

1

2

3

RAIL

C

The rail and anchor system allows you to slightly level your ceiling if needed. Note that it is not recommended to install your entire ceiling on the last level of the rail (3). For a safe and secure installation, the rail must be on the first two levels.

SECONDARY CROSSBAR

04 INSTALL THE MAIN CROSSBARS

You can now install the main crossbars (fig. D) by sliding the rails (fig. B) into the anchors (fig. A) that have been secured to the joists across the entire span of the room. To avoid any pendulum effects during installation, we recommend that you install the main crossbars followed by 1 or 2 rows of secondary crossbars (fig. C), including any cut crossbars. To fit the crossbars together use the tongue & groove portions and slide a rail into place at every joint.

D

E

Add the tiles (fig. E) and secondary crossbars (fig. C) by starting in the center of the room and alternating on either side.

TRICKS How to create a tenon when cutting a secondary crossbar Finishing along side walls Use a 2” x 3” inch cut of a tile and attach it to the raw MDF side of the • Secure the last row of cut end of the secondary crossbar. This will allow the cut off piece to main crossbars against reach the highest part of the main crossbar. the wall. • Measure the length How to create an outside corner needed between the last main crossbar and To make an outside corner, cut the end of your main crossbar and the wall, and the secondary crossbar at 45 degree angles. Attach a tile off-cut where the previous one, and cut your secondary two crossbars meet at the 45 degree angle to hold and secure the crossbar accordingly. It is important to joint. make a tight cut in order to solidify the whole structure, to reduce the Installing recessed spot lights movements of components. Most recessed spot lights are designed to be installed on standard • When cutting the last row of tiles for the suspended ceiling tiles or on drywall that is 1/2” thick. Since Embassy open spaces along side walls, avoid fitting tiles are 1/4” thick, we suggest using tile cut-offs (such as those from them too tightly. Leaving a space making the holes) to create a 1/2” inch layer of MDF placed under the between the tile and the secondary tightening brackets of the spot lights. crossbar will allow the MDF to adjust to the humidity level. * When making a dowel or an outside corner piece, we recommend • Because you have cut one end of a using shorter screws such as 1/2 inch. secondary crossbar, you will have to add a tenon so it can be inserted between the last two main crossbars.

IN MDF WRAPPED WITH POLYPROPYLENE MAIN CROSSBAR

05 INSTALL THE TILES AND SECONDARY CROSSBARS

TILES : 2x2 ou 2x4

F INSTALLATION TEMPLATE PATENT :

SUSPENDED CEILING SYSTEM

CA: # 2588300 - # 2754550 - # 2855427 - # 2837410 # 2855430 - # 2833714 - # 3022306 US: # 9340976- # 9670674 - # 9091053 - # 9243405 # 10557265 EU : # EP2721226

Quick and easy installation Durable and easy to clean laminated MDF Allows a clearance of 1-3/4" No visible nails or screws Stable rails and anchors system with adjustable height Easy access to ducts, pipes and electrical cables Compatible with recessed lighting

Tiles

2x2 2x4


CUSTOMER SERVICE | TECHNICAL SUPPORT

Q UAN T I T Y

77

62

63

64

65

66

67

68

69

42

43

44

45

46

47

48

49

50

28

29

30

31

32

33

34

35

36

37

38

39

15

16

17

18

19

20

21

22

23

24

25

26

27

2

3

4

5

6

7

8

9

10

11

12

13

14

(measurements in feet, inches)

(measurements in feet, inches)

02

02

RAILS & ANCHORS

RESULT GRID

TILES 2’X2’

MAIN CROSSBAR

SECONDARY CROSSBAR

RAILS & ANCHORS

RESULT GRID

TILES 2’X2’

MAIN CROSSBAR

SECONDARY CROSSBAR

RAILS & ANCHORS

RESULT GRID

TILES 2’X2’

MAIN CROSSBAR

SECONDARY CROSSBAR

RAILS & ANCHORS

RESULT GRID

TILES 2’X2’

MAIN CROSSBAR

SECONDARY CROSSBAR

RAILS & ANCHORS

2

1

3

6

22

19

12

38

66

43

30

13

45

78

64

57

24

76

126

85

86

33

104

174

2

3

2

5

12

23

21

12

42

72

44

34

14

51

84

65

63

24

84

144

86

95

36

116

192

3

4

2

7

12

24

24

13

47

78

45

38

18

57

96

66

70

26

93

156

87

104

39

128

210

4

5

3

9

18

25

26

14

51

84

46

42

18

63

108

67

76

28

101

168

88

114

42

139

228

5

6

3

11

18

26

28

16

55

90

47

47

19

70

114

68

82

32

110

180

89

123

45

151

252

6

7

4

13

24

27

30

17

59

102

48

51

21

76

126

69

89

33

118

198

90

133

48

162

270

7

8

5

15

30

28

10

5

16

30

49

55

24

82

138

70

52

19

67

114

91

105

36

126

210

8

9

5

17

30

29

13

6

21

36

50

59

25

89

150

71

59

21

76

126

92

116

39

139

228

9

10

6

19

36

30

16

8

27

48

51

27

11

37

66

72

67

27

86

144

93

126

42

152

252

10

11

6

21

36

31

19

10

32

54

52

32

14

45

78

73

74

27

95

156

94

137

48

164

270

11

12

7

24

42

32

23

11

37

66

53

37

15

52

90

74

81

29

104

174

95

147

50

177

294

12

13

7

26

42

33

26

12

42

72

54

42

17

59

102

75

89

32

114

192

96

128

42

151

252

13

14

8

28

48

34

29

15

48

78

55

48

21

67

114

76

96

36

123

204

97

139

46

164

270

14

15

9

30

54

35

32

15

53

90

56

53

21

74

126

77

103

37

133

222

98

151

52

178

294

15

5

4

9

18

36

35

16

58

96

57

58

23

81

138

78

68

24

84

138

99

162

54

192

318

110

111

112

101

102

103

104

from 24 1/12 to 26 3/12

89

90

91

92

93

94

95

96

from 21 11/12 to 24 1/12

81

82

83

84

85

86

87

88

from 19 9/12 to 21 11/12

73

74

75

76

77

78

79

80

from 17 7/12 to 19 9/12

65

66

67

68

69

70

71

72

from 15 5/12 to 17 7/12

57

58

59

60

61

62

63

64

from 13 3/12 to 15 5/12

49

50

51

52

53

54

55

56

from 11 1/12 to 13 3/12

41

42

43

44

45

46

47

48

from 8 11/12 to 11 1/12

33

34

35

36

37

38

39

40

from 6 9/12 to 8 11/12

25

26

27

28

29

30

31

32

from 4 7/12 to 6 9/12

17

18

19

20

21

22

23

24

from 2 5/12 to 4 7/12

9

10

11

12

13

14

15

16

from 0 to 2 5/12

1

2

3

4

5

6

7

8

1

2

2

3

12

29

21

18

30

102

57

9

10

17

36

85

58

39

81

216

2

3

3

5

18

30

26

20

34

120

58

17

12

34

72

86

70

44

93

264

3

4

4

6

24

31

30

24

38

144

59

26

20

42

102

87

81

52

104

306

4

5

5

7

30

32

31

25

42

150

60

34

23

51

138

88

83

54

116

318

B

5

6

6

8

36

33

6

7

11

30

61

42

30

59

168

89

13

14

26

54

6

7

7

9

42

34

11

8

21

48

62

51

34

68

204

90

26

16

51

96 144

Simple Quick

SSY

1

EM

109

100

Width of the wall perpendicular to the joists (equivalent to the largest dimension)

QUANTITY TABLES

AS

108

99

A

SECONDARY CROSSBAR

QUANTITY TABLES

MAIN CROSSBAR

from 4 7/12 to 6 9/12

ROOM DIMENSION CHART

TILES 2’X2’

Width of the wall perpendicular to the joists (equivalent to the largest dimension)

ROOM DIMENSION CHART

RESULT GRID

from 28 5/12 to 30 7/12

41

from 26 3/12 to 28 5/12

40

from 24 1/12 to 26 3/12

60

from 21 11/12 to 24 1/12

59

from 19 9/12 to 21 11/12

58

from 17 7/12 to 19 9/12

57

from 15 5/12 to 17 7/12

56

from 11 1/12 to 13 3/12

55

01

01

107

98

ONLINE CALCULATOR

INSTALLATION VIDEOS

7

8

8

10

48

35

16

14

27

72

63

59

40

76

234

91

38

28

63

8

9

9

11

54

36

21

16

32

96

64

61

41

84

246

92

51

32

76

192

9

3

4

5

18

37

27

21

37

120

65

10

11

19

42

93

63

42

89

234

10

5

5

9

30

38

32

24

42

144

66

19

13

38

78

94

76

47

101

282

11

7

8

11

42

39

37

28

48

168

67

29

22

48

114

95

89

56

114

330 342

12

9

9

13

54

40

38

29

53

174

68

38

25

57

150

96

91

58

126

13

11

12

15

72

41

7

8

13

30

69

48

33

67

186

97

14

15

28

54

14

13

14

17

84

42

13

10

26

60

70

57

37

76

222

98

28

18

55

102

15

15

16

19

96

43

19

16

32

84

71

67

44

86

258

99

41

30

69

156

16

16

17

21

102

44

26

18

38

108

72

69

46

95

270

100

55

34

82

204

17

4

5

7

18

45

32

24

45

138

73

11

12

21

42

101

69

45

96

252

18

7

6

13

36

46

38

27

51

162

74

21

14

42

84

102

82

50

110

300

19

10

10

16

54

47

45

32

57

186

75

32

24

53

126

103

96

60

123

348

20

13

12

19

72

48

46

33

63

198

76

42

27

63

162

104

99

62

137

366

21

16

15

23

84

49

8

9

15

36

77

53

36

74

204

105

15

16

30

60

22

19

17

26

102

50

15

11

30

66

78

63

40

84

240

106

30

19

59

114

16

7

5

13

24

37

38

18

63

108

58

63

25

89

150

79

76

30

95

156

100

152

49

177

294

23

23

20

29

120

51

23

18

37

96

79

74

48

95

282

107

45

32

74

162

17

9

6

17

30

38

41

20

69

114

59

69

28

96

162

80

84

30

105

174

101

164

56

192

318

24

24

21

32

126

52

30

21

45

120

80

76

50

105

294

108

59

36

89

216

18

11

7

21

36

39

45

21

74

126

60

74

29

103

174

81

93

32

116

192

102

177

58

206

342

25

5

6

9

24

53

37

27

52

150

81

12

13

24

48

109

74

48

103

270

19

13

8

26

42

40

17

7

26

42

61

38

16

51

84

82

101

35

126

210

103

178

60

205

336

26

9

7

17

42

54

45

30

59

180

82

24

15

47

90

110

89

54

118

324

20

15

9

30

54

41

21

9

32

54

62

45

18

59

102

83

110

40

137

228

104

192

64

221

366

27

13

12

21

66

55

52

36

67

210

83

35

26

58

132

111

103

64

133

372

21

17

10

34

60

42

26

12

38

66

63

51

20

68

114

84

118

41

147

246

105

206

66

236

390

28

17

14

26

84

56

54

37

74

222

84

47

30

70

174

112

107

66

147

390

4 9 9 9 -X- 1 6 3 -0

76

106

97

from 29 5/12 to 33 7/12

75

54

from 2 5/12 to 4 7/12

1 from 0 to 2 5/12

from 0 to 2

74

53

from 4 7/12 to 6 9/12

5/ 12

73

52

from 6 9/12 to 8 11/12

from 2 5/12 to 4 7/12

72

51

from 8 11/12 to 11 1/12

11

1/ 12

from 6 9/12 to 8 11/12

from 8

71

1 pc

RAILS & ANCHORS

61

from 11 1/12 to 13 3/12

70

Installation Template

SECONDARY CROSSBAR

84

G200

from 25 3/12 to 29 5/12

83

10 of each

MAIN CROSSBAR

82

Rail & Anchor

from 21 1/12 to 25 3/12

81

RA20B

TILES 2’X4’

80

10 pcs

RESULT GRID

79

White secondary crossbar

from 16 11/12 to 21 1/12

90

C201WHB

RAILS & ANCHORS

89

10 pcs

from 12 9/12 to 16 11/12

88

White main crossbar

SECONDARY CROSSBAR

87

M200WHB

from 8 7/12 to 12 9/12

86

4 pcs

MAIN CROSSBAR

85

White tile, 2’ X 4’

TILES 2’X4’

95

P24WHB

RESULT GRID

94

4 pcs

105

from 0 to 4 5/12

93

White tile, 2' X 2’

from 26 3/12 to 28 5/12

RAILS & ANCHORS

92

2x4

2x2

P22WHB

SECONDARY CROSSBAR

from 13 3/12 to 15 5/12

99

Each installation requires the use of a template.

Qty/pkg

MAIN CROSSBAR

78

from 15 5/12 to 17 7/12

98

91

from 19 9/12 to 21 11/12 from 17 7/12 to 19 9/12

97

Each installation requires the use of a template.

DESCRIPTION

from 28 5/12 to 30 7/12

TILES 2’X4’

96

from 21 11/12 to 24 1/12

Tile

RAILS & ANCHORS

100 101 102

from 24 1/12 to 26 3/12

11/ 12 to

Tile

SECONDARY CROSSBAR

103 104

MAIN CROSSBAR

from 26 3/12 to 28 5/12

30

TILES 2’X4’

105

from 28

width perp to the joistsendicular

Y

7/ 12

width parallel joists to the

RESULT GRID

Use this result from the «Room dimensions grid» (step 2) to find the corresponding number in the left column of the « Quantity table » for the various quantities you will need for your ceiling.

from 13 3/12 to 15 5/12

Width of the wall parallel to the joists (equivalent to the smallest dimension)

Use the «Room dimensions grid» on the right to find the ceiling’s dimensions. If the exact dimensions are not listed, use the next largest numbers.

Depending on your room's configuration, these grids include at least a 5% overhang. These grids are based on a central installation. Feel free to consult our online calculators available on our website.

Width of the wall parallel to the joists (equivalent to the smallest dimension)

02 QUANTITY

EAS

01 ROOM DIMENSIONS

Please note that this range of Embassy Ceilings meets the Class C criteria according to ASTM E84. Embassy suspended ceilings acoustic and soundproofing properties are similar to gypsum.

MODEL

from 4 5/12 to 8 7/12

STANDARDS AND PROPERTIES

STEPS

5/ 12 to

WARNING 2x2|2x4

RESULT GRID

CALCULATOR

365, 6th Street, Daveluyville, QC G0Z 1C0 info@embassyinc.ca | embassyceiling.com


Turn static files into dynamic content formats.

Create a flipbook
Embassy Ceilings Brochure (English) by Alexandria Moulding - Issuu