AISHA TAHIR
ARCHITECTURAL PORTFOLIO
SELECTED WORK 2019-2022
Page|2
PERSONAL INFROMATION
HELLO
My name is Aisha Tahir, 4th year student from Amity School Of Architecture And Planning, Noida. I’ve completed more than half of the architecture course, and willing to learn more. Functional and ergonomic solutions, in my opinion, can result in pure aesthetics. I always take responsibility into account when approaching a work, and make an effort to perform my best along with my team altogether. I am skilled at creating project blueprints by hand and knowledgeable on interpersonal communications as a leader and time management crucial in this line of work.
I believe that beautiful architecture will be architecture that has an internal space that attracts us, elevates us, subjugates us spiritually.
Page|3
Nationality:Indian LINKS aisha.tahir.273@gmail.com +9643187786 www.linkedin.com/in/aisha-tahir
Name: Aisha Tahir Date of Birth: 24 March,2000
2019
Senior secondary School (10th and 12th ) J.B.M Global school, Sector 132, Noida
2019 -Present
Bachlor in Architecture,Amity School of Architectire and Planning,Noida
LEADERSHIP
Class Representative Of Batch 2019-Present
Co-ordinated ANDC 2021-22 NASA India President Of Internship Committee
Sports Captain Of Amity School Architecture And Planning Department
Council Member Of Cultural Society Treasurer Of Exhibition Club Member Of Shooting Club
WORKSHOPS
Lighting As an element of Design Seminar by Ar.Ashish Bahal
Glass Performance Semiar by Mr.Sudhir Mohan and Ms Anushree Gupta
Energy Audit Seminar by Ar.Dehadani; Associate Drector:Technical Development at GBCI Inadia
Magic Carpet Workshop held on zonal NASA Convention 2019 in Z153-Poornima University
Page|4
Adobe
Adobe
Adobe
SOFTWARE
InDesign
Photoshop
Illustrator
Software Autodesk
3D
Rendering
V-ray
EDUCATION 2D
AutoCAD Revit
Modelling Google Sketchup
Software
Enscape Rhinoceros 3D: Rhino Visualization Curriculum
PARTICIPATION
NASA India
2019-2020
Laurie Baker Trophy Special mention; Documentation, Analysis,Research, sketches and Design:Hamlet for a Tribal Community Reubens
2020-2021
Laurie Baker torphy Top 9;Analysis, Research, Drawing and Design:Primary Health Centre
ANDC
Top 110; Analysis, Research, Drawing and Design:Bus Terminal for a Post Pandamic World
HUDCO Surveying, Analysis, Drafting, Research, Drawing & sketches and Design:Sustainable and Affordable Rental Housing
2021-2022 ANDC
Top 24; Documentation, Analysis and Design:Migrant Woker Moble Housing Tophy Coordinator
HUDCO Special mention; Documentation, Analysis, Research, Drawing and Design:Vernacular Housing to Combat Climate Change
Laurie Baker Trophy Documentation, Analysis, Drafting, Research, sketches and Design:Student Co-Housing
OAN
Documentation, Analysis, Research and Design:Identification urgent problems in a community and develop interventions Trophy Coordinator
Re-Vision
120 hours
SANGATHAN
2019 Basketball -3rd Lawn tennis -2nd Netball -2nd
2020 Lawn Tennis-1st Shooting-2nd 2021 shooting-3rd
Page|5 Curriculum Vitae
Architecture is the assumption that art will be realised in accordance with reality and human behaviour, producing the best possible environment for art. Although we changed and reviewed it, nothing changed. I therefore want to learn more about how collaboration may enhance both the quality of human life and the environment in which we live.
Page|6
Page|7 CONTENT MULTI-SPECIALITY HOSPITAL GROUP HOUSING WORKING DRAWING COMPETITIONS MISCELLANEOUS 01. 02. 03. 04. 05.
CONCEPT
MULTI-SPECIALITY HOSPITAL
“Simplicity is the ultimate sophistication”
100 Bedded Multi-Speciality Hospital 3rd year Studio\2022 Location-Sector 50,Noida,U.P,India Area-3.6 Acres
The fundamental ideas surrounding hospitals and healthcare facilities, including the need for healthcare facilities in both urban and rural areas, the various types and specialties of hospitals, factors affecting hospital size, the ideal location for a hospital in a city, town, or village, and accessibility to hospitals.
The necessary zoning needed for a hospital building design project will help define the different functional spaces and their needed area specifications.This will also help clarify where these functions should be located in a hospital building.
The orientation of the hospital building is where the long side is towards east-west
A separate entrance to each department derives the form from a cuboid, which is then further detailed out.
Difference in floor plate to give confound viewes and more innteractive places
Page|8
01.
Page|9 LEGEND
Page|10 LEGEND
Page|11 LEGEND
Page|12 LEGEND
Page|13 LEGEND
Page|14 LEGEND
Page|15 LEGEND
Page|16
SECTION
Page|17
HOUSING
Group Housing 4rd year Studio\2022
Location-Near okhla,Delhi,India
Area-12.4 Acres
The brief is to create a home development. Integrating allied disciplines including engineering services, landscape design, and site planning principles to provide a comprehensive approach in the design of a housing project on a site with a finite physical, cultural, and climatological context
Designing housing should take climate and environmental factors into account to create functional indoor and outdoor environments that are meaningful.
Concept
The spaces in neighbourhoods that emphasise nature, where there is room for gathering with neighbours and where there is foliage to block heat and noise.
The design takes into account a number of guiding principles when planning and designing precincts. The design provides a strong foundation for holistic planning and design of neighbourhood landscapes so that our residents can enjoy a strong sense of place and well-being.
Page|18
02.
Page|19
Page|20
EWS
No. of units:428 Units in a cluster:16 No.of Cluster:4
LIG
No. of units:286 Units in a cluster:8 No.of Cluster:4
Page|21
MIG-1
No. of units:215 Units in a cluster:8 No.of Cluster:2
Page|22
Page|23
MIG-2
No. of units:115 Units in a cluster:4 No.of Cluster:1
Page|24
Page|25
HIG
No. of units:76 Units in a cluster:2 No.of Cluster:2
Page|26
Page|27
Basement Level 1
Page|28 fire duct fire duct ductfire 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000
Basement Level 2
Page|29 fire duct fire duct ductfire 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000
Page|30 A A' R= 150 STAIRCASE STAIRCASE W= 1200 W= 1200 T= 300 R= 150 KEY PLAN HIG SCALE 1:500 ENTRY3/EXIT SITE PLAN SCALE 1:1000
Page|31 B B' LVL+39600 THIRTEENTH FLOOR LVL+36600 TWELTH FLOOR LVL+33600 ELEVENTH FLOOR LVL+30600 TENTH FLOOR LVL+27600 NINGTH FLOOR LVL+24600 EIGHTH FLOOR LVL+21000 SEVENTH FLOOR LVL+18600 SIXTH FLOOR LVL+15600 FIFTH FLOOR LVL+12600 FOURTH FLOOR LVL+9600 THIRD FLOOR LVL+6600 SECOND FLOOR LVL+3600 FIRST FLOOR LVL +600 PLINTH LEVEL LVL -3500 BASEMENT 1 LVL -6500 X1 X2 X3 X4 X5 X6 X7 X8 STUDENT NAME: C CHECKED SECTIONS TITLE DATE 28.11.2022 R E V I S I O N S PROJECT NAME: HOUSING Ar.Vivek Walia AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL AND PLANNING SHEET SIZE A1 Ar.Sangeeta Singh Ar. Shagun Agarwal Ar. Shradhanjalli Mishra ARCHITECTURE This drawing is the property of Amity school of Architecture & Planning, Noida and shall not be used, copied or reproduced without their written permission. BATCH:2019-2024 SEMESTER: 7TH SIGN: REMARK: KEY PLAN EWS &LIG SCALE 1:500 SECTION BB' SCALE 1:200 ENTRY1/EXIT ENTRY2/EXIT 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 8000 000 8000 8000 8000 8000 A' A A' A STUDENT NAME: C SITE SECTION R E V S I O N S PROJECT NAME: HOUSING Ar.Vivek Walia NOTES : KEY PLAN : AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL AND PLANNING SHEET SIZE A1 Ar.Sangeeta Singh Ar. Shagun Agarwal Ar. Shradhanjalli Mishra ARCHITECTURE This drawing is the property of Amity school of Architecture & Planning, Noida and shall not be used, copied or reproduced without their written permission. BATCH:2019-2024 SEMESTER: 7TH ONLY TO BE READ AND NOT SCALED. MENTIONED, ALL DIMENSIONS ARE GIVEN IN MILIMETERS IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, AND 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE N.G.L. 5. ANY DISCREPANCY BETWEEN SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE PROJECT MANAGER BEFORE EXCECUTION OF THE SAME NORTH BASEMENT 1 PLAN SCALE 1:1000 SECTION AA' SCALE 1:200
Page|32
Page|33
LENGTH
NOT LESS THAN
AS GIVEN IN THE TABLE N0 -
FOOTING
HAVING
, ANCHORAGE
LAP LENGTH OF THE BARS
TO OUTER
COLUMN
OF
BEAM
THE LAPS IN BARS SHALL BE STAGGERED &AT ONE PLACE SHALL NOT BE MORE THAN 33.3 PERCENT & MAXIMUM UP TO 50 PERCENT 8 THE DIMENSIONS ARE NEITHER TO BE SCALED NOT THE NUMBER OF THE BARS TO BE COUNTED ONLY WRITTEN DIRECTIONS ARE TO BE FOLLOWED 9 ALL DRAWING SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL & STRUCTURAL DRAWINGS 10 IN BEAMS WHERE THERE ARE MORE THAN ONE LAYER OF REINF. A SPACER BAR SHALL BE PROVIDED BETWEEN TWO LAYER AT A SPACING 1500 c/c THE DIA OF SUCH BARS SHALL BE EQUAL TO THE MAX.SIZE OF BAR IN THE LAYERS (OR) MIN. 20 MM 11 .(a) AVOID LAPS IN BOTTOM BARS NEAR MID SPAN (b) AVOID LAPS IN TOP BARS NEAR SUPPORTS 12. ALL CENTER LINE DIMENSIONS LEVELS ETC SHALL BE EXTRACTED FROM ARCHITECTURAL DRAWINGS . 13 DISCREPANCY FOUND IF ANY , SHALL BE BROUGHT TO THE KNOWLEDGE OF ARCHITECT BEFORE EXECUTION
Page|34 03.WORKING DRAWING COLUMN MKD. CONC. MIX C1 C2 C3 C4 M-25 M-25 M-25 FOUNDATION TO FIRST FLOOR LVL FIRST FLOOR LVL TO SECOND FLOOR LVL SECOND FLOOR LVL TO TERRACE LVL ABOVE TERRACE M-25 300 300 600 300 300 600 300 300 300 300 300 300 300 300 300 300 300 600 300 600 300 600 300 600 SCHEDULE OF ISOLATED FOOTING FOOT MARK CONC. DIMENSION REINFORCEMENT (BOTTOM) F1 F2 LONG SIDE SHORT SIDE LONG SIDE SHORT SIDE 1100 1100 RAD 10 RAD 10 3000 3000 RAD 12 RAD 12 100 600 SECTION CC' 150 300 100 2000 200 N.G,L FOUNDATION TOP 300 SECTION AA' 100 250 SECTION BB' 100 600 SECTION DD' COLUMN PEDESTAL SLAB AS STR. 300 WATER PROOFING 300 600 COLUMN P.C.C. DETAIL FOR ECCENTRIC CASE GENERAL NOTES : 1 . ALL DIMENSIONS ARE IN mm 2 DO NOT SCALE ANY DIMENSION 3 THE GRADE OF ALL R.C.C WORK SHALL BE M25 U.N.O UNLESS NOTED OTHERWISE ) 4 . THE REINFORCEMENT SHALL BE T.M.T BARS CONFORMING TO I.S. 1755 1979
14
15
16
FOR ANY
PLACE
17
THREE
LOADING SHEET TITLE: COLUMNS AND FOOTING SUBJECT NAME SUBJECT CODE BUILDING CONSTRUCTION-IV ARCH-220 INSTITUTE NAME AMITY SCHOOL OF ARCHITECTURE AND PLANNING SHEET NO SHEET SIZE 2 A1 FACULTY IN-CHARGE AR. PRERNA SHARMA AR. SANGEETA SINGH DRAWING UNITS DATE METRIC(MM) 31-01-20121 DRAWN BY AISHA TAHIR ENROLMENT NUMBER A1904019001
YIELD STRENGTH
-500 N/mm2 5 THE DEVELOPMENT LENGTH
,
&
SHALL BE
1 6 THE CLEAR COVER
LAYER
R/F SHALL BE (a)
50 mm (b)
40 mm (c) FLOOR
25 MM (d) FLOOR SLAB 20 mm 7
WATER PROOFING TREATMENT , AS APPROVED , SHALL BE PROVIDED BELOW BASEMENT RAFT AND AT OUTER FACE OF RETAINING WALLS IN CASE OF BASEMENT
DISTRIBUTION STEEL WHEREVER NOT MENTIONED , SHALL BE ADOPTED AS RADIUS 8mm @ 200c/c
IN NO CASE THIS DRAWING SHALL BE USED
SIMILAR PROJECT, AT ANY OTHER
/ SITE .
S.B.C HAS BEEN DESIGNED FOR G+2 TOTAL
STOREY
Page|35 NOTES:ALL DIMENSIONS ARE IN MM, UNLESS NOTED OTHER WISE. (U.N.O.). DO NOT SCALE ANY DRG. FOLLOW WRITTEN DIMENSIONS ONLY. THIS DRG. SHOULD BE READ IN CONJUNCTION WITH RELEVANT ARCH. AND SERVICE DRGS. ANY DISCREPANCY SHOULD BE BROUGHT TO THE NOTICE OF CONSULTANT IMMEDIATALY CONTRACTOR TO VERIFY ALL DIM BEFORE COMMENCEMENT OF WORK. Notes :ALL R.C.C. WORK SHALL BE DONE AS PER IS : 456-2000 1. GRADE OF CONCRETE 1.1. FOR COLUMN TO BE = M:30 1.2. FOR FOOTING TO BE = M:25 1.3. ALL P.C.C TO BE = M:10 2. GRADE OF REINFORCEMENT = Fe500(HYSD) (OF TESTED & APPROVED QUALITY) 3. REFER THIS DRG. IN CORRELATION TO FOLLOWING STRUCTURAL DRGS -----4. FOR DESIGN OF FOUNDATION SBC OF 14.5T/SQM HAS BEEN CONSIDERED 3M. BELOW N.G.L. 5. COVER TO THE MAIN REINFORCEMENT SHALL BE AS FOLLOW :BOTTOM TOP SIDE IN COLUMN IN FOOTING 50MM 50MM 50MM IN RETAINING WALL 40 MM FOR FACE IN CONTACT WITH EARTH/WATER. 20 MM FOR FACE AWAY FROM EARTH/WATER. 6. DEVELOPMENT LENGTH FOR REINFORCEMENT (FOR Fe500) TOR STEEL MIX OF CONC. BAR IN TENSION & BENDING BAR IN COMPRESSION M 25 49 X d 49 X d Y3 Y4 Y5 Y6 Y7 Y8 X3 X1 X4 X5 X6 X9 1580 1470 1180 2615 3345 1460 2155 RAFT FOUNDATION PLAN RETAINING WALL 115 THK BRICK 150MM THK 115 THK BRICK 1100 5212 C2 C2 C1 F2 F1 MEDUP LVL N.G.L CONC. SLAB 150MM THK BRICK WALL RETAINING WALL 150MM THK COLUMN FOUNDATION REINF. 100 MM LEAN CONCRETE {1:4:8} RETAINING WALL 150 MM THK PEDESTAL BRICK BLAST FLOOR FINISH 3600 100 300 2800 1150 4350 200 600 600 300 300 CONC. SLAB 150MM THK 115 THK BRICK 115 THK BRICK SECTION A' 200 800 200 800 200 400 100 300 300 300 3100 1150 400 3300 N.G.L CONC. SLAB 150MM THK COLUMN FOUNDATION REINF. 100 MM LEAN CONCRETE {1:4:8} PEDESTAL PEDESTAL PEDESTAL PEDESTAL SCHEDULE OF ISOLATED FOOTING FOOT MARK CONC. DIMENSION REINFORCEMENT (BOTTOM) F1 F2 LONG SIDE SHORT SIDE LONG SIDE SHORT SIDE 1100 1100 RAD 10 RAD 10 3000 3000 RAD 12 RAD 12 CF1 CF2 RAD 12 RAD 12 RAD 12 RAD 12 5260 4080 4380 2300 COLUMN MKD. CONC. MIX C1 C2 C3 C4 M-25 M-25 M-25 FOUNDATION TO FIRST FLOOR LVL FIRST FLOOR LVL TO SECOND FLOOR LVL SECOND FLOOR LVL TO TERRACE LVL ABOVE TERRACE M-25 300 300 600 300 300 600 300 300 300 300 300 300 300 300 300 300 300 600 300 600 300 600 300 600 SHEET TITLE: RAFT FOUNDATION SUBJECT NAME SUBJECT CODE BUILDING CONSTRUCTION-IV ARCH-220 INSTITUTE NAME AMITY SCHOOL OF ARCHITECTURE AND PLANNING SHEET NO SHEET SIZE 3 A1 FACULTY IN-CHARGE AR. PRERNA SHARMA AR. SANGEETA SINGH DRAWING UNITS DATE METRIC(MM) 31-01-20121 DRAWN BY AISHA TAHIR ENROLMENT NUMBER A1904019001 UP 1100 1100 GROUND FLOOR PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 X +300MM 100 +1800MM X1 2630 X2 Y1 X' TREAD:250 RISER:150 WIDTH:1100 UP 1100 1100 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 X 00MM 100 -1400MM X1 2630 X2 Y1 X' TREAD:250 RISER:150 WIDTH:1100 BASEMENT PLAN MUMMTY+9600MM G.F.L.+300MM F.F.L.+3300MM TERRACE.+6300MM N.F.L.+00MM 3000 SECTION XX' FLOORING AS PER SPEC. 100MM R.C.C. SLAB 40MM THICK COPING BRICKBAT COBA 3000 550 3000 TERRACING DETAIL PLINTH BEAM 900 MM HIGH RAILING 100MM P.C.C. SLAB 100MM SAND RAMMED EARTH 900 MM HIGH RAILING A 340 R.C.C. CHAJJA 600 200 800 2200 TERRACE.+7200MM TERRACING DETAIL BRICKBAT COBA 715 900 50 135 900 MM HIGH RAILING 1185 RISER:150 TREAD:250 22MM THICK MARBLE WIDTH:1100 12MM NOSING 1185 22MM THICK MARBLE 12MM NOSING RISER:150 WIDTH:1100 TREAD:250 A 1185 RISER:150 WIDTH:1100 TREAD:250 3000 RAILING DETAIL 900 HANDRAIL MS PIPE BALUSTER 35MM 50MM DIA 1.6MM TH. 150 250 CEM. PLASTER FINISH 22MM THICK MARBLE 20MM THICK MORTAR BRICK WORK 22MM THICK MARBLE 20MM THICK MORTAR RCC SLAB 150 125 250 DETAIL A 12MM NOSING BRICK WORK 100 100MM HIGH SKIRTING DOWN UP 10 FIRST FLOOR PLAN TERRACE FLOOR PLAN 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 +3300MM +5100MM +6300MM +5100MM 2630 2630 Y1 X1 X2 X1 X2 X' Y1 X X X' TREAD:250 TREAD:250 RISER:150 WIDTH:1100 RISER:150 WIDTH:1100 1100 1100 100 1100 1100 100 ARCHITECTURAL CONSULTANT and shall not be used, copied or reproduced without their written permission. This drawing is the property of Amity school of Architecture & Planning, Noida C CHECKED STAIRSCASE DETAIL TITLE DATE 03.03.2022 DRG. NO. DEALT RETAIL BLOCK STATUS SCALE G.F.C REV. R E V I S O N S PROJECT NAME: MIXED USED COMPLEX NAME BHUVAN MITRA ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER BEFORE N.G.L. AS BENCHMARKED AT SITE MILIMETERS. NOTES : 1. DRAWING AND DIMENSIONS ARE ONLY TO BE READ AND NOT SCALED. 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE EXCECUTION OF THE SAME KEY PLAN : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL ARCHITECTURE AND PLANNING SHEET SIZE A1 S.NO. NOMANCLATURE SIZE D1 1400 X 2500 1 2 3 4 5 D2 D3 D4 D5 800 X 2000 2000 X 2500 1000 X 2000 1700 X 2500
Page|36 252411 44364 155373 214799 88129 44991 111608 82603 24M WIDE ROAD 18M WIDE ROAD 24M WIDE ROAD 45M WIDE ROAD 12M 9M 12M 15 M 12M 15 M 12M SITE AREA = 41,600 SQ.M. PERMISSIBLE GROUND COVERAGE(40%) = 16,640 SQ.M PROPOSED GROUND COVERAGE (25.9%) = 10,800 SQ.M PERMISSIBLE F.A.R.(3) = 1,24,800 SQ.M PROPOSED F.A.R.(2.65) =1,10,399 SQ.M SETBACK SETBACK SETBACK SETBACK SETBACK SETBACK SETBACK SETBACK 12M 90° 90° 90° 90° 90° 90° 90° 90° ARCHITECTURAL CONSULTANT and shall not be used, copied or reproduced without their written permission. This drawing is the property of Amity school of Architecture & Planning, Noida C CHECKED SITE PLANNING TITLE DATE 03.03.2022 DRG. NO. DEALT RETAIL BLOCK STATUS 1:1000 SCALE REV. R E V S I O N S REV. NO. DATE DESCRIPTION NAME: MIXED USED COMPLEX BHUVAN MITRA ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER BEFORE MILIMETERS. NOTES : 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE 5. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL OR SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE EXCECUTION OF THE SAME KEY PLAN : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL ARCHITECTURE AND PLANNING SHEET SIZE A1 SITE PLAN 155373 90° ENTRY 1 ENTRY 2 EXIT 2 EXIT 3 ENTRY 3 ENTRY 4 EXIT 4 EXIT 1 214799 1 2 3 4 5 6 7 8 9 10 11 12 A B C D E F G a c d e f g h k m n o b 62000 10000 10000 10000 10000 12000 10000 13 14 15 p q r 10000 6285 565 6150 10000 9135865 5150 10000 8985 1015 6500 6500 10000 91150 10000 9135 86510000 10000 8659135 10000 9135 86510000 5650 85650 7212 30789920 10000 30210 99711 98722 53551 100256 96285 252411 44364 155373 214799 88129 44991 111608 82603 12M 9M 12M 15 M 12M 15 M 12M A1 SETBACK SETBACK SETBACK SETBACK SETBACK SETBACK SETBACK SETBACK 115483 A2 79647 A3 A4 A5 ARCHITECTURAL CONSULTANT and shall not be used, copied or reproduced without their written permission. This drawing is the property of Amity school of Architecture & Planning, Noida C CHECKED SITE DEMARCATION PLAN TITLE DATE 03.03.2022 DRG. NO. DEALT RETAIL BLOCK STATUS 1:1000 R E V I S O N S REV. NO. PROJECT DATE DESCRIPTION NAME: MIXED USED COMPLEX NAME BHUVAN MITRA ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER BEFORE N.G.L. AS BENCHMARKED AT SITE MILIMETERS. NOTES : 1. DRAWING AND DIMENSIONS ARE ONLY TO BE READ AND NOT SCALED. 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE 5. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL OR SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE EXCECUTION OF THE SAME KEY PLAN : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL ARCHITECTURE AND PLANNING SHEET SIZE A1
Page|37 STORAGE STORAGE GENERATOR Y1 BASEMENT -1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y20 Y21 Y22 Y23 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 Y19 Y20 Y21 Y22 Y23 X1 A B C D E F G H I X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y1 Y2 Y3 Y4 Y5 SITE PLAN ARCHITECTURAL CONSULTANT and shall not be used, copied or reproduced without their written permission. This drawing is the property of Amity school of Architecture & Planning, Noida C CHECKED BASEMENT PLAN TITLE DATE 03.03.2022 DRG. NO. DEALT RETAIL BLOCK STATUS 1:500 SCALE REV. R E V I S O N S NAME: MIXED USED COMPLEX BHUVAN MITRA ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER BEFORE MILIMETERS. NOTES : 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE 5. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL OR SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE EXCECUTION OF THE SAME KEY PLAN : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL ARCHITECTURE AND PLANNING SHEET SIZE A1 S.NO. NOMANCLATURE SIZE D1 1400 X 2500 1 2 3 4 5 D2 D3 D4 D5 800 X 2000 2000 X 2500 1000 X 2000 1700 X 2500 252411 44364 155373 88129 111608 90° SECTION AA' SECTION BB' SECTION CC' SECTION DD' SECTION EE' SECTION FF' 3200 00 BASEMENT LEVEL 3200 -3200 3200 3200 GROUND LEVEL 3200 3200 -3200 14198 168737 66922 10740 143221 14198 89821 75696 46853 69429 120492 1518 27772 162162 1518 10740 23834 1518 105° 105° 105° 105° 105° 105° 105° 105° 105° 105° 105° 105° 252411 44364 155373 214799 88129 111608 168819 25424 23951 96684 38553 41652 75676 41663 30657 122108 27766 90° 90° 90° 90° 90° 90° 90° 90° 90° 90° ARCHITECTURAL CONSULTANT and shall not be used, copied or reproduced without their written permission. This drawing is the property of Amity school of Architecture & Planning, Noida C CHECKED SECTION OF EXCAVATION TITLE 03.03.2022 DRG. NO. RETAIL BLOCK STATUS 1:500 SCALE REV. R E V I S O N S REV. NO. PROJECT DATE DESCRIPTION NAME: MIXED USED COMPLEX NAME BHUVAN MITRA ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER BEFORE N.G.L. AS BENCHMARKED AT SITE MILIMETERS. NOTES : 1. DRAWING AND DIMENSIONS ARE ONLY TO BE READ AND NOT SCALED. 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE KEY PLAN : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL ARCHITECTURE AND PLANNING SHEET SIZE A1 EXCAVATION PLAN
Page|38 A A' 10000 6285 6150 10000 6500 12000 9135 62000 10000 10000 10000 10000 10000 565 10000 9920 1015 865 10000 865 91150 5150 9135 5650 3078 7212 9135 865 10000 8985 85650 6500 10000 10000 30210 9135 10000 865 10000 10000 X1 A B C D E F G H I X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y1 Y2 Y3 Y4 Y5 SECTION AA' 300 150 92000 300 300 150 ARCHITECTURAL CONSULTANT and shall not be used, copied or reproduced without their written permission. This drawing is the property of Amity school of Architecture & Planning, Noida C CHECKED FRAMING PLAN TITLE DATE 03.03.2022 DEALT RETAIL BLOCK STATUS SCALE G.F.C REV. S.NO. PROJECT NOMANCLATURE SIZE NAME: MIXED USED COMPLEX NAME BHUVAN MITRA ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER BEFORE N.G.L. AS BENCHMARKED AT SITE NOTES : 1. DRAWING AND DIMENSIONS ARE ONLY TO BE READ AND NOT SCALED. 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE 5. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL OR SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE EXCECUTION OF THE SAME KEY PLAN : NAME:AISHA TAHIR ENROL:A1904019001 AMITY SCHOOL ARCHITECTURE AND PLANNING SHEET SIZE A1 SECTION AA' SCALE 1:50 FRAMING PLAN SCALE 1:300 SITE PLAN 62000 10000 6500 6500 12000 865 865 10000 10000 1015 6285 30210 5150 8985 91150 10000 565 5650 9135 10000 10000 9135 85650 10000 10000 10000 6150 865 9135 10000 9920 10000 865 7212 3078 10000 10000 10000 9135 10000 X1 A B C D E F G H I X2 X3 X4 X5 X6 X7 X8 X9 X10 X11 X12 X13 X14 X15 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y1 Y2 Y3 Y4 Y5 ARCHITECTURAL CONSULTANT and shall not be used, copied or reproduced without their written permission. This drawing is the property of Amity school of Architecture & Planning, Noida C CHECKED RAFT FOOTING LAYOUT DATE 03.03.2022 DRG. NO. DEALT RETAIL BLOCK STATUS 1:200 SCALE G.F.C S.NO. PROJECT NOMANCLATURE SIZE NAME: MIXED USED COMPLEX NAME BHUVAN MITRA ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER BEFORE N.G.L. AS BENCHMARKED AT SITE NOTES : 1. DRAWING AND DIMENSIONS ARE ONLY TO BE READ AND NOT SCALED. 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE 5. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL OR SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE EXCECUTION OF THE SAME KEY PLAN : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL ARCHITECTURE AND PLANNING SHEET SIZE A1
Page|39 X1 X5 X3 X2 X4 X7 X6 X9 X8 X10 X11 X14 X12 X15 X13 Y15 Y16 Y17 X1 A B C D E F G 90LARGESHOPS SQM LARGESHOPS SQM LARGESHOPS SQM LARGESHOPS SQM MEDIUM SHOPS 50SQM H I X5 X3 X2 X4 X7 X6 X9 X8 X10 X11 Y2 X14 X12 X15 X13 Y1 Y3 Y7 Y4 Y6 Y5 Y8 Y9 Y10 Z1 Y11 Y12 Z4 Y13 Z2 Z3 Z5 A' A' LARGESHOPS SQM 90LARGESHOPS SQM 90LARGESHOPS SQM 90LARGESHOPS SQM MEDIUM SHOPS SQM LARGESHOPS SQM X1 A B C D E F G H I X5 X3 X2 X4 X7 X6 X9 X8 X10 Y2 X14 X12 X15 X13 Y1 Y3 Y7 Y4 Y6 Y5 Y8 Y9 Z1 Z4 Z2 Z3 Z5 A' A' BASEMENT -1 Y10 X1 A C D E F G H X3 X7 Y3 BUILDING SECTION TITLE 03.03.2022 DRG. NO. RETAIL BLOCK 1:200 SCALE PROJECT BHUVAN MITRA NOTES : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: SHEET SIZE A1 SECTION:B SEMESTER:6TH AMITY SCHOOL OF ARCHITECTURE AND PLANNING NAME:MIXED USED COMPLEX 1. DRAWING AND BE READ AND NOT SCALED. MENTIONED, ALL DIMENSIONS ARE GIVEN IN MILIMETERS. SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. DRAWING ARE WITH REFERENCE TO THE N.G.L. AS BENCHMARKED AT SITE 5. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BY THE ,BEFORE EXCECUTION OF THE SAME SECTION AA' SCALE :1:200 GROUND FLOOR PLAN FIRST FLOOR PLAN C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C1 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C2 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C3 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C4 C1 C4 C1 C4 C4 565 6500 10000 10000 9135 10000 10000 10000 7212 10000 30210 7250 A B 550 550 850 30 850 62000 10000 10000 10000 6150 9135 10000 5150 865 10000 8985 1015 91150 865 865 85650 9920 6500 9135 10000 6285 865 5650 3078 9135 12000 7250 840 850 840 11910 30 1000 C 1000 850 850 850 D X1 A B C D E F G H I X5 X3 X2 X4 X7 X6 X9 X8 X10 X11 Y2 X14 X12 X15 X13 Y1 Y3 Y7 Y4 Y6 Y5 Y8 Y9 Y10 Z1 Y11 Y12 Z4 Y13 Z2 Z3 Z5 SCHEDULE OF COLUMN SN.O LENGTH WIDTH 1 2 3 4 1000 850 850 850 850 650 850 550 COLUMN C1 C2 C3 C4 C1 C4 850 650 850 1000 30 C2 C2 550 550 30 850 850 C3 C3 850 850 850 30 850 C4 C4 30 1000 1000 850 850 COLUMN LAYOUT DRG. NO. RETAIL BLOCK 1:200 SCALE PROJECT NOTES : NAME:AISHA TAHIR ENROL:A1904019001 INSTITUTE: SHEET SIZE A1 SECTION:B SEMESTER:6TH BATCH:2019-24 AMITY SCHOOL OF ARCHITECTURE AND PLANNING NAME:MIXED USED COMPLEX 1. DRAWING AND DIMENSIONS ARE ONLY TO BE READ AND NOT UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN MILIMETERS. 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE N.G.L. AS BENCHMARKED AT ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL OR SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR OR ,BEFORE EXCECUTION OF THE SAME SCALE: 1:200 COLUMN LAYOUT SCALE: 1:50 DETAIL A SCALE: 1:50 DETAIL B SCALE: 1:50 DETAIL C SCALE: 1:50 DETAIL D
Page|40 80Ø 65Ø 65Ø 40Ø 40Ø 32Ø 32Ø 32Ø 25Ø 25Ø 25Ø ELECTRICAL SHAFT 150Ø FIRE RISER 80Ø DRAIN PIPE WASTE PIPE 80Ø ISOLATING VALVE FLOW SWITCH L.V.SHAFT 40Ø 40Ø 32Ø 32Ø 32Ø 25Ø 25Ø 25Ø 65Ø 40Ø 32Ø 25Ø 40Ø 32Ø 32Ø 40Ø 32Ø 25Ø 40Ø 32Ø 32Ø F D E S C R P T I O N OPTICAL TYPE SMOKE DETECTOR ELECTRONIC HOOTER RESPONSE INDICATOR MANUAL CALL POINT ( BREAK GLASS TYPE SYSTEM FIRE WATER LINE FOR SPRINKLER ISOLATING VALVE 15 M.M. DIA SIDE WALL SPRINKLER HEAD INDICATIVE CONDUIT RUN (25Ø) (FOR FIRE ALARM SPRINKLER PIPE SLEEVE LEGEND ( FIRE FIGHTING & ALARM SYSTEM ) SYMBOL MIG -2 CLUSTER PLAN TYPICAL FIRE LAYOUT SCALE 1:100 TYPICAL PLUMBING LAYOUT SCALE 1:100
Page|41 G. TV TV G. TV G. G. ELECTRICAL SHAFT TV TV G. TV G. G. TV TV G. TV G. G. TV TV G. TV G. G. 150Ø FIRE RISER 80Ø DRAIN PIPE WASTE PIPE 80Ø ISOLATING VALVE FLOW SWITCH L.V.SHAFT STUDENT NAME: C CHECKED ELECTRICAL, FIRE AND TITLE DATE 28.11.2022 R E V I S I O N S PROJECT NAME: HOUSING Ar.Vivek Walia NOTES : KEY PLAN : AISHA TAHIR ENROL:A1904019001 INSTITUTE: AMITY SCHOOL AND PLANNING SHEET SIZE A1 Ar.Sangeeta Singh Ar. Shagun Agarwal Ar. Shradhanjalli Mishra ARCHITECTURE This drawing is the property of Amity school of Architecture & Planning, Noida and shall not be used, copied or reproduced without their written permission. BATCH:2019-2024 SEMESTER: 7TH SIGN: 1. DRAWING AND DIMENSIONS ARE ONLY TO BE READ AND NOT SCALED. 2. UNLESS OTHERWISE MENTIONED, ALL DIMENSIONS ARE GIVEN IN MILIMETERS 3. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH RELEVANT ARCHITECTURAL, STRUCTURAL, AND SERVICES DRAWINGS. 4. ALL LEVELS GIVEN IN DRAWING ARE WITH REFERENCE TO THE N.G.L. AS BENCHMARKED AT SITE 5. ANY DISCREPANCY BETWEEN THE ARCHITECTURAL/STRUCTURAL OR SERVICES DRAWINGS MUST BE BROUGHT TO THE ATTENTION OF THE ARCHITECT BY THE CONTRACTOR OR PROJECT MANAGER , BEFORE EXCECUTION OF THE SAME . NORTH REMARK: PLUMBING LAYOUT MIG-2 CLUSTER MIG -2 CLUSTER PLAN TYPICAL ELECTRICAL LAYOUT SCALE 1:100
Page|42
Page|43
COMPETITONS
Laurie Baker Trophy’2019-2020 Hamlet for a Tribal Community Group Competition
Page|44 04.
Brief: T0 is to prepare the design of a hamlet for a tribal community.
The design of the dwelling units must incorporate the Per capita design concept that was advocated by Laurie Baker. Houses under social housing schemes are usually built according to a predecided template dictated by the provision of the bare basic requirements and least cost government housing programs.
Achievements :Special mention,Top 3, Shortlisted
Contributions: Documentation, Surveying, Analysis, Drafting, Content Research, Drawing & sketches.
Page|45
Page|46
Design Competetion’2020-2021
Achievements: Shortlisting in Top 110 Contribution Decoding of brief and shortlisting of site,Analysis, Research, Drawing and sketchs
Annual NASA
Design: Bus Terminal for a Post Pandamic World Brief: In current scenario, uncontrollable mobility at every square mile had given rise to increase in crowded spaces. The mobility at spaces are vecoming horspots for transmission of diseases and hence caged people inside their homes. Redesigning a simple area like Bus Terminal in order to imagine the post-Pandemic world’s mobility areas in accordance to the people.
Page|47
Design: Sustainable and Affordable Rental Housig
Brief:To generate innovatve housing design solution for varied geo-climatic zones that address the sustance of vernacular resoursces and design practices for affordable settlement in the contemporary context
Achievements Special mention,Top 3, Shortlisted
Contribution
Decoding of brief and shortlisting of site,Analysis, Research, Drawing and sketchs
Page|48
Housing and Urban Development Corporation Limited(HUDCO)’2021-2022
Page|49
Brief:The design must be collapsible and easily employed over a variety of terrain,stages of construction weather condition.The design, most importantly, must address the core problems concerning safety,security,privacy and right to dignified lives for labourers. The design units must be able to adapt to various iterations of arrangement that would be called in the construction process
Page|50
Design Competetion’2021-2022
Annual NASA
Design: Migrant Woker Group Competition
Woker Mobile Houding Competition
construction and safety,security,privacy for different points
Achievements: Shortlisting in Top 24
Contributions: Trophy Coodinator; Documentation, Analysis, Design Process, Rendering, Content Research & Writing.
Page|51
Competetion’2021-2022
Page|52
Laying the Foundation
Laying the tyres
Connecting the frame & putting the flooring board
Putting in the walls (Bracing,insulation & finish)
Putting the roof
Your Dwelling unit is complete
Page|53
ASSEMBLING THE DWELLING UNIT DETAILS
DISMANTELLING THE UNITS
Page|54
SITE PLANNING AND CONSIDERATION
Page|55
Page|56
05. MISCELLANEOUS PHOTOGRAPHY
Page|57
Page|58 CALLIGRAPHY PAINTING SKETCHS DRAWING
Page|59 120 HOUR(2022)
Page|60 Renders
Model Making
aisha.tahir.273@gmail.com +91 9643187786 www.linkedin.com/in/aisha-tahir-872627256