CIVILENGINEER

RLG,Inc. 12001N.CentralExpressway,Suite300 Dallas,TX75243

ProjectManager:EdgarCecena

Email:ececena@rlginc.com Phone:972.322.5072

1.ExistingConditions:

A.Informationcontainedonthesedrawingswithregardtoexistingconditionsfor constructioninnowayreleasestheContractorfromtheresponsibilityforverifying completelyallfieldconditionsrelatingtoandaffectingtheexecutionofthework, asdescribedintheseContractDocuments.Ceasework,notifyArchitect,and awaitinstructionsifmaterialsorconditionsencounteredatthesitearenotas indicatedbytheContractDocuments.

B.Fieldverificationofexistingconditionsrelatingtospecificportionsofthework shallbeundertakeninadvancetoallowforthetimelyidentificationofexisting conditionsthatmayeffectthescheduledinstallationofnewworkasdesignedand detailed,andtoavoidundueandunreasonabledelaystotheprojectshouldsuch conditionsbediscovered.Timelyidentificationsofsuchconditionsshallprovide forareasonableperiodoftimeduringwhichtheArchitectwillevaluatethe conditionsandmakerecommendationsforaccommodatingnewwork.

C.AssisttheArchitectinmakingtheirevaluationsandrecommendationsby providinginatimelymanner,atnoadditionalcosttotheOwner,accurateand completedrawings,sketches,andphotographssufficienttoclearlydescribe discrepancies,conflicts,andconcealedorotherwiseunanticipatedexisting conditionsaffectingnewconstruction.AssisttheArchitectbyprovidinginatimely mannerpreparedsolutionstounanticipatedexistingconditions.

D.TheArchitecthasendeavoredtoidentifyascompletelyaspossibleinthe drawingsandspecificationsexistingitemsthatarerequiredtoberemovedor otherwisedemolishedsoastoallowtheexecutionofnewwork.Thisinformation isprovidedfortheconvenienceoftheContractor,andisinnowayintendedto meanthatdemolitionislimitedonlytothoseitemsspecificallyidentified.Execute demolitionworkasrequiredtoallowtheexecutionofnewwork.

E.Areasanditemsindicatinglimitsofworkandlinesofdemarcationareshownfor theconvenienceoftheContractor,andarenottobetakenliterally.Actual contractlimitsaretobedeterminedpriortobidopeningsbyfieldverification.

F.Originalelementsremovedaretobere-installedintheiroriginallocation,unless notedotherwise.

2.BlockingandFraming

A.Somegeneralassumptionshavebeenmadeonexistingblocking,framing,and existingmasonryprofileswhereconditionshavenotbeenuncovered.Re-secure existingblockingasnecessaryandprovidenewblockingasneededatdoor frames,doorcasings,windows,windowcasing,baseboards,chairrail,andother millworkareas.

3.Dimensionoforiginalmaterials:

A.DimensionsindicatedinConstructionDocumentsfororiginalmaterialsare approximateandaretobefieldverifiedpriortosubmittalofshopdrawings. Matchexactsizesandprofilesoforiginalelements,unlessnotedotherwise.

4.Sealants A.Removeexistingsealantsandreplacewithspecifiedsealants,typical.

5.Masonryinfill: A.Masonryinfillistomatchadjacentmaterialtype,size,coursing,color,mortar,etc.

6.Exterior: F.Existingconstructionshowntoremainshallnotbedamagedduringthedemolition process.Providetemporaryprotectionasnecessary.Ifsurfacesofwallare damaged,damagedareasshallberepairedwithmasonrytomatchexistingand restorethefullstructuralcapacityofthewalls. G.ShoringdrawingsandassociatedstructuralcalculationssealedbyaProfessional EngineerlicensedintheStateofTexasshallbesubmittedtotheArchitect'sfile andshallnotbereturnedapprovedtotheContractor.TheContractorissolely responsibleforthedesignandinstallationofallshoringnecessarytoaccomplish thework.

H.Allshoringshalltransferloadingdirectlytoexistingmasonrystructure.Shoring shallbedesignedtosupportthefullanticipatedloadingwithnobenefitfromthe existingstructuralframing. I.Themaximumallowableloadingontheexistingfloorstructuresshallbe100psf. Allareasofthebuildingwhichmayhavegreaterloadingimposedonitbythe Contractor'sdemolitionprocedureshallbeshored.

GENERALMEP&AUDIOVISUALNOTES

1.Concealmentofconduit,piping,anddevices,general:

A.Conduit,piping,anddevicesarenottobeexposedinanylocationunless approvedbyArchitect.

B.Electricalboxesandassociatedelementsmustberecessedintowalls,floors,or baseboardssothatcoverplatesareflushwiththefinishsurface.

2.Concealmentofconduit,piping,anddevicesatwalls: A.Conduit,wiring,andpipingaretobeconcealedbehindfinishfaceofplasterwalls unlessnotedotherwise.

B.Routeconduitintotheplasterandmasonrysothatafullapplicationoflathand plastersystemisinstalledoverthematerialandconduitandpipingisconcealed inwallsbehindtheplaster.

maximum2-inchesforhorizontalrunsand4-inchesforverticalruns.

3.Concealmentofconduit,piping,anddevicesatconcretefloors: A.Conduitcannotbeembeddedintheexistingconcreteslab.Installconduit, piping,anddevicesinclearspacebetweentheconcreteandsuspendedor finishedceiling.Contractortoverifyfloor/ceilingassemblyandthedirectionof thejoists/beamspriortothestartofthework.

4.Concealmentofconduit,piping,anddevicesatconcretecolumnsandbeams: A.RoutingisnotpermittedunlessapprovedbyStructuralEngineer.

B.Conduitandpipingistobeconcealedbehindfurr-outsatcolumnfaceand aroundbeamsasdetailed.

5.Exposedconduit,piping,anddevicesatceilings: A.Whereverpossiblemakeeveryefforttorunconduitandpipingconcealedwithin scheduledfurr-downsorbetweenexistingfloor/ceilingjoists.Wherenot possiblerunconduitandpipinginthemostdirectandshortestrouteandreturn toclosestfurr-downfollowingthecriterialistedunderitem9andrelated architecturaldetails.

6.Exposedconduit,piping,anddevices: A.Runparalleltowallsandbeams. B.Gangpipingandconduitinparallelgroupswherepossibleandequidistantto eachother.Whengangedpipingisbent,itmustremainequidistanttoeach other.

7.Newfasteners: A.Attachmenttostone,brick,(i.e.conduit,metalframing,woodfurring,etc…) mustbeattachedintomasonryjointsunlessnotedotherwise.Donotdrill through,penetrateoralterinanywaytheoriginalmaterialsorstructureunless notedotherwise.

B.RefertostructuralforattachmentrequirementsofMEPequipmenttostructure.

8.Penetrationatmasonrywalls: A.Cut/coreplasterandmasonrywallsasnecessarytoaccommodatenew materials,components,andsystemsincludingconduit,wiring,piping,ducts,and allotheritemsrequiredforinstallationandoperationofelectrical,mechanical, andplumbingsystems.Seestructuraldrawingsforpenetrationdetailsat masonryloadbearingwalls.

9.MEPShopDrawings: A.Mechanicalductworkandpipingshopdrawingsaretoincludespot elevationstothebottomofthesesystemsabovefinishfloortoverifyclearances atsuspendedceilingsandfurr-downs.

Note

BASEBID:THESCOPEOFWORKINCLUDEDINTHEBASEBID INCLUDESRESTORATION/REHABILITATIONOFTHEEXTERIOR, INTERIORCORRIDORS,AUDITORIUM,RESTROOMS,ANDBREAK ROOM.

ALTERNATENO.1:THESCOPEOFWORKINCLUDEDIN ALTERNATENO.1INCLUDESRESTORATION/REHABILITATION OFTHEINTERIORCLASSROOMSOFTHEORIGINALBUILDING ANDTHE1950S/1960SADDITION,UNISEXRESTROOM,AND BREAKROOM.REF.FLOORPLANFORBASEBIDVS.ALT.NO. DIAGRAM. ALTERNATENO.2:PROVIDEREPLACEMENTEXTERIORDOORS ATTHEADDITIONINCLUDINGHARDWARE,PAINT.MATCH HISTORICCONFIGURATION.

ATLANTA-MILLERGRADESCHOOL RESTORATIONANDREHABILITATION PLUS/MINUS DIAMETER AIRCONDITIONER ASBESTOSCONTAINING MATERIAL AIRHANDLINGUNIT CABINETS CEILING CONCRETE DOWN ELEVATOR EQUAL EQUIPMENT EXISTING FIXTURES FLOOR FIRERATED GYPSUM HISTORIC MECHANICAL MISCELLANEOUS METAL ONCENTER ORIGINAL QUARTER REFERENCE REQUIRED STRUCTURAL TOBEDETERMINED TYPICAL UNLESSOTHERWISENOTED VERIFYINFIELD WITH WOOD ± Ø A/C ACM AHU CABS. CLG. CONC. DN. ELEV. EQ. EQUIP. EXIST. FIXT. FLR. F.R. GYP. HIST. MECH. MISC. MTL. OC ORIG. QTR. REF. REQ'D STRUCT. T.B.D. TYP. U.O.N VIF W/ WD. NOTE:CONTRACTORSHALLVERIFY WITHARCHITECTFORANY ABBREVIATIONNOTLISTED. ARCHITECT OWNER INDEXOFDRAWINGS Architexas Architecture,Planning,andHistoricPreservation,Inc. 1023SpringdaleRoad Bldg.11,SuiteE Austin,TX78721 PrincipalInCharge:AlexisMcKinney,AIA Email:amckinney@architexas.com Phone:512.444.4220 AtlantaGradeSchoolFriends P.O.Box851 Atlanta,Texas75551 Phone:903.824.4471 OwnerRepresentative:DannyStanley Email:tdstanley111@gmail.com ABBREVIATIONS PROJECT LOCATION SITE LOCATION ARCHITECTURAL A-0.01 COVERSHEET A-0.02 PROJECTINFO.&ADADIAGRAMS A-0.03 LIFESAFETYDIAGRAMS D-1.01 DEMOLITIONSITEPLAN D-1.02 DEMOLITIONFLOORPLAN A-1.01 SITEPLAN A-1.02 SITEPLANDETAILS A-2.01 FLOORPLAN A-2.02 REFLECTEDCEILINGPLAN A-2.11 ROOFPLAN A-2.21 ENLARGEDBREAKRM.PLAN&INT.ELEV. A-2.22 ENLARGEDR.R.PLANS&INT.ELEV. A-3.01 SOUTHANDWESTEXTERIORELEVATIONS A-3.02 NORTHANDEASTEXTERIORELEVATIONS A-4.01 BUILDINGSECTION A-5.01 DOORSCHEDULE&DETAILS A-5.10 WINDOWSCHEDULE&TYPES A-5.20 INTERIORELEVATIONS A-6.01 FINISHSCHEDULE&WALLTYPES Atlanta,Texas MAPCOURTESYOFGOOGLE.COM AREAMAP LOCATORMAP MAPCOURTESYOFGOOGLE.COM STRUCTURALENGINEER LostArtStructures 11782JollyvilleRoad Austin,TX78759 Owner:ZachWebb,PE Email:zach@lostartstructures.com Phone:512.219.4000 MEPENGINEER BrownConsultingEngineers,Inc. 3505Olsen,Suite110 Amarillo,TX79109 Owner:TravisP.Brown,PE Email:Travis.brown@brownconsultingengineers.com Phone:806.354.0141 GENERALNOTES SYMBOLSLEGEND RoomNameandNumber WallType WindowType CenterLine ColumnCenterLines DoorType X/A.X.00 X/A.X.00 DetailSection ElevationKey DetailKey DetailKey WallSection BrokenSection SheetMetal Aluminum Steel Glass SplitFaceCMU Existing,WhereNoted HollowClayTile MetalLathandPlaster GypsumBoard CeramicTile SprayedFireInsulation SprayedInsulation MATERIALSLEGEND Masonry Concrete GravelFill Earth/CompactFill AcousticBattInsulation ThermalBattInsulation RigidInsulation FinishWood RoughWood Plywood Blocking C.Atbrickwallsrouteminimumdepthrequiredforinstallationofconduitto
ROOM NAME 222 SQFT
A-0.01 CoverSheet 1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com ATLANTA-MILLER GRADESCHOOL 1061/2W.MillerSt. Atlanta,Texas75551 COPYRIGHT TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden. REVISIONHISTORY 1.100%DD 15February2024 ArchitexasNo. Date 15February2024 2246 SheetName SheetNumber NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24
A-0.02 PROJECTINFORMATION&ADA DIAGRAMS 1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com ATLANTA-MILLER GRADESCHOOL 1061/2W.MillerSt. Atlanta,Texas75551 COPYRIGHT TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden. REVISIONHISTORY 1.100%DD 15February2024 ArchitexasNo. Date 15February2024 2246 SheetName SheetNumber NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24 3 ADAStall SideWallElevation 2 ADAStall RearWallElevation 1Typ.ADAStallPlan 5 ADAGrab BarClearances 7Typ.ADAMountingHeights REFUGE AREAOF 4 ADASingle UserToiletStallPlan 8 ADASink (SideElev.andPlan) 6 ADASink,Mirror, andSoapDispenser 9 ADAHi/Low DrinkingFountainElevation 10 Min.Clearance @DoorsinaSeries 17 Min.Clearance@Doors FrontApproach,PullSide 14 Min.Clearance@Doors FrontApproach,PushSide 13 Min.Clearance@Doors HingeApproach,PullSide 11 Min.Clearance@Doors HingeApproach,PullSide 12 Min.Clearance@Doors LatchApproach,PullSide 19 Min.Clearance@Doors HingeApproach,PushSide 16 Min.Clearance@Doors LatchApproach,PushSide 18 ADAControlReachLimitations (Forward/SideReachPossible) MEN L C 10max 48 max 34 max 34 max 46 max >10-24max 20ADAProjectionLimitations 15ADASignage

SUMMARYSHEET–BUILDINGCODE

Completelysuppressed: Yes* Corridorrating:0-hour

Compartmentation: Yes* Requireddoorclosers:Yes

FireResistanceratingofverticalopeningenclosures:N/A

TypeofproposedHVACsystem:VRFsystemwithair&/orwatersourceheatpump&fancoil.

Automaticfiredetection: Yes Type&location:Smokedetectorsthroughout.

Firealarmsystem: Yes* Type:Firealarmsystemcomplyingw/Sect.907plus EmergencyVoice/alarm&firecommandstation*

Smokecontrol: No Type:N/A

Adequateexitroutes: Yes Deadends:N

Maximumexitaccesstraveldistance:200'-0" Elevatorcontrols:N/A

Meansofegressemergencylighting: Y Mixedoccupancies:No

ALLOWABLEHEIGHTANDBUILDINGAREA(Table503):

notapplicable ThisindicatesthatafiresprinklersystemisnotrequiredthroughoutthefloorareacontainingtheGroupA-3 occupancy.Theownerhasdecidedtoinstallafiresprinklerthroughoutthebuilding.

1061/2W.MillerSt.

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION

ArchitexasNo. Date 15February2024

SheetName

A-0.03 LifeSafety 1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com ATLANTA-MILLER GRADESCHOOL
Atlanta,Texas75551
2246
SheetNumber
ALEXISMCKINNEY,2/15/24 PLANNORTH N 1LifeSafetyFloorPlan Scale:1/8"=1'-0" DuringConstruction ApplicableCode(s): 1. InternationalBuildingCode(IBC)–2021Edition 2. UniformPlumbingCode(UPC)–2021Edition 3. InternationalMechanicalCode(IMC)–2021Edition 4. InternationalExistingBuildingCode(IEBC) 2021Edition OCCUPANTLOAD(Table1004.5) TheOccupantloadbelowisbasedupontheproposedfloorplanlayout(Seeattached). Area OccupantLoad TotalAllowed 1stFloor Business(8,114Grosssq.ft.) 1person/150sq.ft. 55persons A-3(1,039Netsq.ft.) (basedoffseating) 96persons (1person/7sqft) 148persons Stage(196sqft) 1person/15sqft. 13persons TotalBuildingOccupancy 164occ. EITINGREUIREMENTS(Sect.1005.3) MinimumRequirements Provided 1stFloor 164personsx0.15”=24.6” 55.2” 4Exits@60”
Existing/Formeroccupancyload:E/A-3 Proposedoccupancy:B/A-3(Business/Assembly) Yearbuildingwasconstructed:1936 NumberofStories: Heightinfeet:27'-6"
V-B Areaperfloor:10,850sq.ft. Percentageofopenperimeter: 100% Percentageofheightreduction:0%
Typeofconstruction:
Occupancy: GroupB/A-3 ConstructionType: V-B(S) Max.numberofstories: 2 Max.allowableareaperstory: 24,000(S-1) Max.height: 60feet TYPEOFCONSTRUCTION(Section602.5) TypeV-Bconstructiondescribestheconstructiontypeofthe1936AtlantaMillerGradeSchool.TypeVconstructionis thattypeofconstructioninwhichthestructuralelements,exteriorwallsandinteriorwallsareofanymaterials permittedbycode. REUIREDFIRERESISTANCERATINGSBASEDONCONSTRUCTIONTYPE(Table601) TypeV-BbuildingshavingspecificfireresistancerequirementsforStructuralComponentsasfollows: Structuralframe 0 Exteriorbearingwalls 0 Interiorbearingwalls 0 Non-bearingwalls 0 Floorconstruction 0 Roofconstruction 0 REUIREDPLUMBINGFITURES(Table2902.1) WaterClosets Male Female A-3Occupancy 55personsat1/125=0.44(1) 55personsat1/65=0.85(1) BOccupancy 28personsat1/25forst50=1.12(2) 28personsat1/25forst50=1.12(2) TOTAL 3 3 Lavatories Male Female A-3Occupancy 55personsat1/200=0.275(1) 55personsat1/200=0.275(1) BOccupancy 28personsat1/40forst80=.7(1) 28personsat1/40forst80=.7(1) TOTAL 2 2 Drinkingfountains bi-leveldrinkingfountain Other servicesink Theproposedplanswillallowfor3waterclosets,and2lavatoriesformen;5waterclosetsand3lavatoriesfor women;and2UnisexRestrooms.AllrestroomsareproposedtobeADAcompliant.
AUTOMATICFIRESPRINKLERSYSTEMS(Section903) Thefollowinginformationindicatesminimumrequirementsforinstallationofafiresprinklersysteminbuildingswith groupAoccupancies: Per903.2.3,Anautomaticfiresprinklersystemshallbeprovidedthroughoutbuildingsandportionsthereofusedas GroupAoccupancies.ForGroupA-3occupancies,theautomaticsprinklersystemshallbeprovidedthroughoutthe floorareawheretheAssemblyoccupancyislocated,andonallfloorsfromtheGroupAoccupancyto,andincluding, thenearestlevelofexitdischargeservingtheGroupA Per903.2.1.3forGroupA-3Anautomaticfiresprinklersystemshallbeprovidedthroughoutafireareacontaininga GroupA-3occupancywhereoneofthefollowingconditionsexist: 1. Theareaexceeds12,000sq.ft.notapplicable 2. Thefireareahasanoccupantloadof300ormorenotapplicable,totalbuildingoccupant loadis164 3. Thefireareaislocatedonafloorotherthanthelevelofexitdischarge
5. InternationalFireCode(IFC)-2021Edition 6. 2021NFPA 7. 2021NFPA101 CONCRETE WALKWAY BREAKROOM 107 ADA/UNISEX114 117A 117B 124 125 116 115 118 117 113A 113 114 111A 111B 110B 110A 110 118A 123 125A 124A 123A 100 102A 102B 103 102 103A 103B 105 106 101 109 120 121 122 108A 108 FOYER 100 WEST HALL 101 CLASS ROOM 102 CLS. 102A CLASS ROOM2 103 CLS. 103A WESTPLUMB.CLS. 106 CLS. 104 WOMEN 105 AUDITORIUM 108 STAGE 108A EAST HALL 109 CLASS ROOM3 110 CLS. 110A CLASS ROOM4 111 ELECTRICALROOM 112 ADMINISTRATION 113 MEN 115 EAST PLUMB. CLS. 116 CLASS ROOM5 117 CLS. 117A CLASS ROOM6 118 HALL 119 TEACHER'S LOUNGE 123 NORTH HALL 120 CLASS ROOM7 124 LUNCH ROOM 125 BREAKRM 121 143SF RR 122 95SF PARKINGANDPASSENGERLOADINGFACILITIES (CityofAtlanta,Section28,off-streetparkingrequirements) TotalParkingSpacesRequiredRequiredMinimumNumberofAccessible Spaces *Assembly3 109occupants/3sq.ft.=37Spaces Or 1,235sq.ft./75sq.ft.=17Spaces (Whicheverisgreater) Business 8,114sq.ft./300sq.ft.=28Spaces Total=65Spaces 1/25=3AccessibleSpaces (59SpacesProvided) *Persection28.04assemblyhall(publicorprivate,includingchurches, auditoriums,ormeetingrooms):One(1)spaceperthree(3)seatsorper seventy-five(75)squarefeetofgrossfloorarea,whicheverisgreater.Office: One(1)spaceforeachthreehundred(300)squarefeetoffloorarea (minimumfive(5)spaces 83' 58' 107 108 SECTION1607LIVELOADS(TABLE1607.1) AssemblyOccupancy Assemblyareas=100lb/ft BusinessOccupancy Lobbies&1stFloorCorridor=100lb/ft Offices=50lb/ft 74' 55 100SF 5459SF B A.M.E.ACCESSIBLEMEANSOFEGRESS EXITACCESSTRAVELDISTANCE(MAX.250') FIREEXTINGUISHERBRACKET(MAX=75FEET) FIREEXTINGUISHERCABINETFULLYRECESSED (MAX.75FEET) FX FE MAX.FLR.AREAALLOWANCEPER OCCUPANT OCCUPANTTOTALPERAREA AREA OCCUPANCYUSE EXIT HRWALL LEGEND 1HRWALL A.M.E.TOADAPARKING A.M.E. TO ADA PARKING
BUILDINGCODEANALYSIS

EXIST.MANUFACTUREDBUILDING

EXIST.MANUFACTUREDBUILDING

GENERALNOTES-SITEDEMO

1.GENERALSITEWORK

A.UTILITYLOCATIONSAREAPPROXIMATE,V.I.F.LOCATEGAS,WATER, ELECTRICAL,ANDOTHERMISC.UTILITYLINESPRIORTOTRENCHING. B.REFERENCECIVIL&MEPDRAWINGSFORSCOPEOFSITEUTILITY WORK.

2.STRUCTURALREMAINS A.PROVIDETEMPORARYPROTECTIONFOREXISTINGSTRUCTURAL REMAINS(BRICKARCH)DURINGCONSTRUCTIONACTIVITIESONSITE.

3.TREEPROTECTION: A.PROTECTEXIST.TREES&ROOTSYSTEMSDURINGEXCAVATING& BACKFILLINGOPERATIONS.IFTREESAREDAMAGEDBY CONSTRUCTIONOPERATIONS,CONTRACTORSHALLOBTAINTHE SERVICESOFACERTIFIEDARBORISTTOPERFORMREPAIRSATNO ADDITIONALCOSTTOTHEOWNER.

4.SITERESTORATION: A.RESTOREDAMAGETOEXIST.LANDSCAPINGSCHEDULEDTOREMAIN ADJACENTTOAREAOFWORKINCLUDINGBUTNOTLIMITEDTO SIDEWALKS,PLANTINGBEDS,CURBS,LAWN,ETC...RESULTINGFROM REMOVALOFABOVEGRADEUTILITIES&INSTALLATIONOF SUBSURFACEUTILITYLINES,MODIFICATIONSTOEXISTING&NEW BUILDINGENTRIES,ETC....

LEGEND-SITEDEMO W

CONCRETEPAVING,ASPHALT, LANDSCAPEAREAS,&MISC. ELEMENTSTOBEREMOVED

ELEMENTSTOBEREMOVED

EXIST.WATER,REF.CIVIL

SAN PROPERTYLINE

EXIST.SANITARYSEWER,REF.CIVIL

AustinDallas

1023SpringdaleRd

ALLTHATCERTAIN1.629ACRETRACTOFLANDINJANERICHEESURVEY,A-877,IN CASSCOUNTY,TEXAS,BEINGALLOFTHECALLED1.629ACRETRACTCONVEYED FROMJOHNW.BARNHILLJR.ANDWIFE,JANEC.BARNHILLTOATLANTAGRADE SCHOOLFRIENDSBYWARRANTYDEEDDATEDAUGUST26,2003,AND RECORDEDINVOLUME1206,PAGE64,INTHEREALPROPERTYRECORDSOF CASSCOUNTY,TEXAS.

ALLTHATCERTAIN0.397ACRETRACTOFLANDINJANERICHEESURVEY,A-877, INCASSCOUNTY,TEXAS,BEINGALLOFTHECALLED0.397ACRETRACT CONVEYEDFROMTRAVISW.DEELANDWIFE,JESSICAA.DEELTOATLANTA GRADESCHOOLFRIENDSBYWARRANTYDEEDDATEDAUGUST20,2022,AND RECORDEDINCLERK'SFILENO.2022001234INTHEREALPROPERTYRECORDS OFCASSCOUNTY,TEXAS.

ATLANTA-MILLER GRADESCHOOL

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

BUCKNERSTREET

NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24

ArchitexasNo. Date 15February2024 2246

SheetName SheetNumber

DEMOLITIONSITEPLAN

Bldg11,SuiteE Austin,Texas78721
p512.444.4220
SanAntonio www.architexas.com
D-1.01
EXIST.ASPHALT EXIST.CONCRETE EXIST. CURB
C.O. GM WM EM EM EXISTTELEPHONE WM WM EXIST.AWNING EXIST.ELECTRICAL TRANSFORMER EM EXIST.CONCRETEBENCHTOREMAIN EXIST.BRICKARCHTOREMAIN EM ACAC ACAC EXIST.NOPARKINGSIGN EXIST.STREETSIGN EXIST.MANHOLE EXIST.FIRE HYDRANT CONC. N TRUENORTH PINE 3'-4"DIA. HACKBERRY 3'-0"DIA. OAK 1'-6"DIA. ATLANTA-MILLER GRADESCHOOL PLANNORTH N
W. MILLER STREET (40' R.O.W.) CONCRETEDRIVEWAY GARAGEFOOTER 3'-6"DIA. OAK OAK 3'-4"DIA. EXIST.GRAVEL CONC. CONCRETE CONCRETE EXIST. CONC. TRACT1 CALLED1.629AC ATLANTAGRADESCHOOLFRIENDS VOL.1206,PG.64 TRACT2 CALLED0.397AC ATLANTAGRADESCHOOLFRIENDS CFN2022001234 DEMO.EXIST.WOODRAMP DEMO.EXIST.AWNING DEMO.EXIST.CONCRETE SIDEWALK EXIST. 1
Scale:1/16"=1'-0" 265 264 264 264 263 262 262 263 264 265 265 265 264 264 261 262 263 264 262 264 265 264 264 265 265 265 266 265 266 265 266 266 266 267 266 266 269 268 268 268 267 268 266 264 263 265 4" PVC 4" PVC 4" PVC 4" PVC 4" PVC 4" PVC 4"PVC 4"PVC 4"PVC 4"PVC
DemolitionSitePlan
WM EM LIGHTPOLE TELEPHONE/POWERPOLE ELECTRICMETER GASMETER GM WATERMETER TREE EXIST.GRAVEL EXIST.CONCRETE
TRACT1 TRACT2

AustinDallas

1023SpringdaleRd

p512.444.4220

ATLANTA-MILLER GRADESCHOOL

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24

ArchitexasNo. Date 15February2024 2246

SheetName

DemolitionFloorPlan

SheetNumber

Bldg11,SuiteE Austin,Texas78721
SanAntonio www.architexas.com
D-1.02
9" WEST HALL 101 CLASS ROOM1 102 CLS. 102A CLASS ROOM2 103 WOMEN 105 OFFICE 107 STOR. 107A STOR. 107B AUDITORIUM 108 STAGE 108A EAST HALL 109 CLASS ROOM3 110 CLS. 110A CLASS ROOM4 111 ELECTRICALROOM 112 ADMINISTRATION 113 JANITOR 114 CLASS ROOM5 117 CLASS ROOM6 118 HALL 119 TEACHER'S LOUNGE 123 NORTH HALL 120 OFFICE2 121 OFFICE3 122 CLASS ROOM7 124 LUNCH ROOM 125 CONCRETE WALKWAY PLANNORTH N 1DemolitionFloorPlan Scale:1/8"=1'-0" MEN 115 117A 117B 124 125 116 115 118 117 113A 113 114 111A 111B 110B 110A 110 118A 123 125A 124A 123A 100 102A 102B 103 102 103A 103B 105 106 101 109 120 121 122 108A 108
EXISTINGWALLS DEMOLISHEDWALLS WESTPLUMB.CLS. 106 1950s/1960s ADDITION BASEBID:THESCOPEOFWORKINCLUDEDINTHEBASEBIDINCLUDES RESTORATION/REHABILITATIONOFTHEEXTERIOR,INTERIORCORRIDORS, AUDITORIUM,RESTROOMS,ANDBREAKROOM(NON-POCHE'DAREASONTHE PLAN). ALTERNATENO.1:THESCOPEOFWORKINCLUDEDINALTERNATENO.1 INCLUDESRESTORATION/REHABILITATIONOFTHEINTERIORCLASSROOMS OFTHEORIGINALBUILDINGANDTHE1950S/1960SADDITION,UNISEX RESTROOM,ANDBREAKROOM.(POCHE'DAREASONTHEPLAN). Note 1950s/1960s ADDITION ORIGINAL CONSTRUCTION 1950S/1960SADDITION ALTERNATENO. BASEBID
LEGEND

EXIST.ASPHALT EXIST.CONCRETE EXIST. CURB

EXIST.MANUFACTUREDBUILDING

W. MILLER STREET (40' R.O.W.) CONCRETEDRIVEWAY GARAGEFOOTER NOPARKING NOPARKING 3'-6"DIA. OAK OAK 3'-4"DIA. 25'-0" 25'-0" CURBRAMP 9'-0"(TYP.) 18'-0" (TYP.) 25'-0" 25'-0" 25'0" MIN. 5'-0" (TYP.) 5'-0"(TYP.) 25'-0" 59PARKINGSPACESTOTAL (65PARKINGSPACESREUIRED) 4HCPARKINGSPACES 2VANACCESSIBLE 11'-0" UP 265 264 264 264 263 262 262 263 264 265 265 265 264 264 261 262 263 264 262 264 265 264 264 265 265 265 266 265 266 265 266 266 266 267 266 266 269 268 268 268 267 268 266 264 263 265 4" PVC 4" PVC 4" PVC 4" PVC 4" PVC 4" PVC 4"PVC 4"PVC 4"PVC 4"PVC

GENERALNOTES-SITEPLAN

1.GENERALSITEWORK A.UTILITYLOCATIONSAREAPPROXIMATE,V.I.F.LOCATEGAS,WATER, ELECTRICAL,ANDOTHERMISC.UTILITYLINESPRIORTOTRENCHING. B.REFERENCECIVIL&MEPDRAWINGSFORSCOPEOFSITEUTILITY WORK.

C.O. GM WM EM EM EXISTTELEPHONE WM WM EXIST.AWNING EXIST.ELECTRICAL TRANSFORMER EM EXIST.CONCRETEBENCHTOREMAIN EXIST.BRICKARCHTOREMAIN EM ACAC ACAC EXIST.NOPARKINGSIGN EXIST.STREETSIGN EXIST.MANHOLE 1ProposedSitePlan Scale:1/16"=1'-0" EXIST.FIRE HYDRANT CONC. N TRUENORTH PINE 3'-4"DIA. HACKBERRY 3'-0"DIA. OAK 1'-6"DIA. ATLANTA-MILLER GRADESCHOOL PLANNORTH N

SanAntonio www.architexas.com

1023SpringdaleRd

2.STRUCTURALREMAINS A.PROVIDETEMPORARYPROTECTIONFOREXISTINGSTRUCTURAL REMAINS(BRICKARCH)DURINGCONSTRUCTIONACTIVITIESONSITE.

3.TREEPROTECTION: A.PROTECTEXIST.TREES&ROOTSYSTEMSDURINGEXCAVATING& BACKFILLINGOPERATIONS.IFTREESAREDAMAGEDBY CONSTRUCTIONOPERATIONS,CONTRACTORSHALLOBTAINTHE SERVICESOFACERTIFIEDARBORISTTOPERFORMREPAIRSATNO ADDITIONALCOSTTOTHEOWNER.

4.SITERESTORATION:

A.RESTOREDAMAGETOEXIST.LANDSCAPINGSCHEDULEDTOREMAIN ADJACENTTOAREAOFWORKINCLUDINGBUTNOTLIMITEDTO SIDEWALKS,PLANTINGBEDS,CURBS,LAWN,ETC...RESULTINGFROM REMOVALOFABOVEGRADEUTILITIES&INSTALLATIONOF SUBSURFACEUTILITYLINES,MODIFICATIONSTOEXISTING&NEW BUILDINGENTRIES,ETC....

LEGEND-SITE

W

EXIST.WATER,REF.CIVIL

SAN PROPERTYLINE

WM EM LIGHTPOLE TELEPHONE/POWERPOLE ELECTRICMETER GASMETER GM WATERMETER TREE

ATLANTA-MILLER GRADESCHOOL

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

ArchitexasNo. Date 15February2024 2246

SheetName SheetNumber

A-1.01
SitePlan Bldg11,SuiteE Austin,Texas78721 p512.444.4220
AustinDallas
NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24
BUCKNERSTREET
EXIST.MANUFACTUREDBUILDING
PROVIDECONCRETEPAVING,CURBS, &GUTTERS
EXIST.SANITARYSEWER,REF.CIVIL
PROVIDEGRASS,MATCHEXIST.

Note

INCLUDESRESTORATION/REHABILITATIONOFTHEINTERIORCLASSROOMS OFTHEORIGINALBUILDINGANDTHE1950S/1960SADDITION,UNISEX RESTROOM,ANDBREAKROOM.(POCHE'DAREASONTHEPLAN). 1950S/1960SADDITION ALTERNATENO. BASEBID

GENERALNOTES-PLANS

2.MASONRYINFILL: A.FILLOPENINGSATABANDONEDMEPPENETRATIONSTOMATCHEXISTING CONSTRUCTION.FINISHWALLS&CEILINGSASSCHEDULEDTOPROVIDEA SEAMLESSTRANSITIONBETWEENEXISTING&NEWCONSTRUCTION.

3.PARTITIONS: A.REFERTOSHT.A-6.01FORPARTITIONTYPES. B.ALLWALLPARTITIONSSHALLBETYPE"1"UNLESSOTHERWISENOTED. C.REPAIRHOLESINEXIST.PARTITIONSSCHEDULEDTOREMAIN.MATCH CONSTRUCTION&FINISHOFEXISTINGWALLASSEMBLYASREQUIREDTO PROVIDEASEAMLESSTRANSITIONBETWEENREPAIREDAREAS&ADJACENT SURFACES.

4.MILLWORK: A.WOODBASE:REFERTOROOMFINISHSCHED.,SHT.A6.01FORSCOPEOFWORK.

5.DOORS:REFERTODOORSCHEDULEONSHT.A-5.01&DETAILEDDOORINVENTORY INTHEAPPENDIXOFTHEPROJECTMANUALFORSCOPEOFWORK.NEWDOORS, NON-HISTORICOPENING,LOCATEHINGESIDE4FROMWALLU.O.N.

6.WINDOWS:REFERTOWINDOWSCHEDULEONSHT.A-5.10FORSCOPEOFWORK.

7.FINISHES:REFERTOROOMFINISHSCHEDULE&GENERALFINISHNOTESONSHT. A-6.01FORSCOPEOFWORK.

8.TOILETACCESSORIES:REFERTOTOILETACCESSORIESSCHEDULEONSHT.A-6.10.

9.FIREEXTINGUISHERS: A.PROVIDERECESSEDCABINETS&WALLMOUNTEDFIREEXTINGUISHERSWHERE SHOWN. B.PROVIDEFIRE-RATEDCABINETSWHERERECESSEDINTOFIRERATEDWALLS.

10.SIGNAGE:PROVIDEROOMSIGNAGETOCOMPLYWITHTAS,REF.SPEC.SECT.10425 -SIGNAGE.

11.INSULATION: A.REFERTOWALLTYPESSHT.A-6.01FORINSULATIONINNEWWALLS. B.ROOF:PROVIDERIGIDINSULATIONATALLROOFSSCHEDULEFORREPLACEMENT, REFERTOROOFPLANSHT.A-2.10.

12.APPLIANCES:APPLIANCESINDICATEDONTHEDRAWINGSSHALLBEPROVIDEDBY THEOWNER.CONTRACTORTOCOORDINATETHEPROPERINFRASTRUCTUREFOR THESELECTEDAPPLIANCES,INCLUDINGCOORDINATIONWITHBUILT-INCABINETRY.

FLOORPLANLEGEND

EXIST.WALLSTOREMAIN

NEWWALLELEMENT FX WALLMOUNTEDFIREEXTINGUISHER DRINKINGFOUNTAIN NEWCONCRETEFLOORASSEMBLY,REF.STRUCT. FE RECESSEDFIREEXTINGUISHERCABINET REPAIRHOLEINWALLATREMOVEDMEP.MATCHEXIST. WALLCONSTRUCTION&FINISH REPLACEMISSING,POORLYPATCHEDORDAMAGED PLASTERFINISH SUPPLYGRILLE RETURNGRILLE 1.DIMENSIONINGATWALLS:

ATLANTA-MILLER GRADESCHOOL

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

ArchitexasNo. Date 15February2024 2246

SheetName

A-2.01
1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com
FloorPlan
SheetNumber
9" CONCRETE WALKWAY 2/A-3.01 1/A-3.01 1/A-3.02 2/A-3.02 1ProposedFloorPlan Scale:1/8"=1'-0" PLANNORTH N EQ. EQ. BREAKROOM 107 ADA/UNISEX 114 REF N.I.C. 96CHAIRS HCSEATING 13STAGESEATS 109TOTAL 1.19 D 1.18 D ADA ACCESSIBLE ENTRANCE 109 1.01 A 1.02 C 1.03 A 1.04 E 1.05 E 1.06 A 1.07 C 1.08 A 1.09 C 1.10 C 1.12 B 1.13 B1 1.14 A 1.15 C 1.16 A 1.17 B2 1.20 A 1.21 C 1.22 A 1.23 E 1.24 C 1.25 C 1.26 C 1.28 A 1.27 A 1.29 A 1.30 B1 1.31 C 1.32 C 1.33 E 1.11 E 1.43 F 1.44 F 117A 117B 124 125 116 115 118 117 113A 113 114 111A 111B 1.42 G 110B 110A 1.40 G 1.41 G 110 118A 123 125A 124A 123A 100 102A 102B 103 102 1.34 G 1.35 G 103A 103B 105 106 101 120 121 122 108A 108 1.36 G 1.37 G 1.38 G 1.39 G N.I.C. FRIDGE N.I.C. WARM N.I.C. DISH N.I.C. FOYER 100 WEST HALL 101 CLASS ROOM1 102 CLS. 102A CLASS ROOM2 103 CLS. 103A CLS. 104 WOMEN 105 AUDITORIUM 108 STAGE 108A EAST HALL 109 CLASS ROOM3 110 CLS. 110A CLASS ROOM4 111 ELECTRICALROOM 112 ADMINISTRATION 113 MEN 115 EAST PLUMB. CLS. 116 CLASS ROOM5 117 CLS. 117A CLASS ROOM6 118 HALL 119 TEACHER'S LOUNGE 123 CLASS ROOM7 124 LUNCH ROOM 125 1950s/1960s ADDITION BREAKRM 121 143SF RR 122 95SF ICE N.I.C. WARM N.I.C. BASEBID:THESCOPEOFWORKINCLUDEDINTHEBASEBIDINCLUDES RESTORATION/REHABILITATIONOFTHEEXTERIOR,INTERIORCORRIDORS, AUDITORIUM,RESTROOMS,ANDBREAKROOM(NON-POCHE'DAREASONTHE PLAN). ALTERNATENO.1:THESCOPEOFWORKINCLUDEDINALTERNATENO.
NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24 1950s/1960s ADDITION ORIGINAL CONSTRUCTION
WALLDIMENSIONSAREFINISHEDFACEOFWALLTO FINISHEDFACEOFWALLU.O.N.

Note 1950S/1960SADDITION ALTERNATENO. BASEBID

BASEBID:THESCOPEOFWORKINCLUDEDINTHEBASEBIDINCLUDES RESTORATION/REHABILITATIONOFTHEEXTERIOR,INTERIORCORRIDORS, AUDITORIUM,RESTROOMS,ANDBREAKROOM(NON-POCHE'DAREASONTHE PLAN).

NOTES

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24

ArchitexasNo. Date 15February2024 2246

SheetName

REFLECTEDCEILINGPLAN

SheetNumber

A-2.02
Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com
1023SpringdaleRd
ATLANTA-MILLER GRADESCHOOL
9" FOYER 100 CLS. 103A WESTPLUMB.CLS. 106 CLS. 104 EAST PLUMB. CLS. 116 CLS. 117A ELECTRICAL PANELS PLANNORTH N 1ProposedRCP Scale:1/8"=1'-0" A B B B H2 H2 H2 H2 H2 H2 B B B B B B 6'-0" 6'-0" H1 H2 H2 H2 H2 H2 H2 H2 H2 H2 6'-0" 6'-0" 6'-0" 6'-0" B B B B B B B B B B B B 6'-0" 6'-0" H2 H2 H2 5'-0" 5'-0" 5'-0" 5'-0" H1 H1 H1 H1 H1 8'-0" 10'-0" H1 10'-0" 10'-0" C C C 2'-0" 2'-0" C C2'-0" C 2'-0" H1 H1 10'-0" 10'-0" B H2 H2 B H2 H2 B B B B B B B H2 H2 6'-0" 6'-0" 5'-0" 5'-0" 5'-0" 5'-0" B H2 H2 B B B B B B B B H2 H2 H2 H2 6'-0" 6'-0" 5'-0" 5'-0" 5'-0" 5'-0" C C 2'-0" C 2'-0" EQ. EQ. B H2 H2 B B B B B B B B H2 H2 H2 H2 6'-0" 6'-0" 5'-0" 5'-0" 5'-0" 5'-0" C C C 2'-0" 2'-0" EQ. EQ. H1 H1 H1 H1 8'-0" 8'-0" 10'-0" 10'-0" H1 H1 7'-0" H1 6'-0" B B B B B B 6'-6" D B B 5'-0" B B B B B BE EQ.EQ. EQ. EQ. EQ. EQ. H2 H2 H2 H2 B B 5'-4" 5'-4" 6'-0" EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ.EQ. EQ. EQ. EQ.EQ. EQ. EQ. EQ. EQ. EQ. EQ. EQ. 6'-6" EQ. B B B B B B B B EQ.4'-3"EQ. 6'-0" 6'-0" 6'-0" EQ. EQ. 4'-3" 4'-3" 4'-3" B B 4'-3" EQ. EQ. EQ. EQ. EQ.5'-0" 5'-0"EQ. A A A 6'-0" EQ. EQ. 5'-0" EQ. EQ. D EQ. EQ. EQ. EQ. ALLCEILINGFINISHHEIGHTS ARE11'-8"ABOVEFINISHFLOOR UNLESSNOTEDOTHERWISE
H1 3'-5" B H2 H2 B B B B B B B B H2 H2 H2 H2 5'-0" 5'-0" 5'-0" 5'-0" EQ. EQ. 6'-0" 6'-0" EQ. EQ. C C C 2'-0" 2'-0" EQ. EQ. C C 4'-0" EQ. EQ. B H2 H2 B B B B B B B B H2 H2 H2 H2 6'-0" 6'-0" 5'-0" 5'-0" 5'-0" 5'-0" EQ. EQ. EQ. EQ. B H2 H2 B B B B B B B B H2 H2 H2 H2 6'-0" 6'-0" 5'-0" 5'-0" 5'-0" 5'-0" EQ. EQ. EQ. EQ. B H2 H2 B B B B B B B B H2 H2 H2 H2 6'-0" 6'-0" EQ. EQ. 5'-0" 5'-0" 5'-0" 5'-0" EQ. EQ. REF N.I.C. OFFICE 123 282SF OPEN OFFICE 124 624SF OPEN OFFICE 125 624SF 1.19 D 1.18 D 1.01 A 1.02 C 1.03 A 1.04 E 1.05 E 1.06 A 1.07 C 1.08 A 1.09 C 1.10 C 1.12 B 1.13 B1 1.14 A 1.15 C 1.16 A 1.17 B2 1.20 A 1.21 C 1.22 A 1.23 E 1.24 C 1.25 C 1.26 C 1.28 A 1.27 A 1.29 A 1.30 B1 1.31 C 1.32 C 1.33 E 1.11 E 1.43 F 1.44 F 117A 117B 124 125 116 115 118 117 113A 113 114 111A 111B 1.42 G 110B 110A 1.40 G 1.41 G 110 118A 123 125A 124A 123A 100 102A 102B 103 102 1.34 G 1.35 G 103A 103B 105 104 106 101 109 120 121 122 108A 108 1.36 G 1.37 G 1.38 G 1.39 G LEGEND EXISTINGWALLS NEWWALLS FREEZERN.I.C. FRIDGE N.I.C. WARM N.I.C. DISH N.I.C. CLASS ROOM2 103 NORTH HALL 120 CLASS ROOM5 117 CLASS ROOM6 118 HALL 119 MEN 115 CLASS ROOM4 111 ELECTRICALROOM 112 ADMINISTRATION 113 AUDITORIUM 108 STAGE 108A EAST HALL 109 CLASS ROOM3 110 CLS. 102A CLS. 110A CLASS ROOM 102 WOMEN 105 1950s/1960s ADDITION WEST HALL 101 confirmlightbarisrequired???? threependantlightfixtures,fillinwithcanlights firesprinklerarea 24"12"panelscenterlightsinpanels. findfixtureforcorridor. closets4'linear MAKELIGHTFIXTURESCHEDULE usethebarnstylefixture.sconceatlavs...NEEDCANSTOO sink,cabinets,dishwasher fridge 2'10counter JANITOR 114 ICE N.I.C. WARM N.I.C. DISHN.I.C.
ALTERNATENO.1:THESCOPEOFWORKINCLUDEDINALTERNATENO.1 INCLUDESRESTORATION/REHABILITATIONOFTHEINTERIORCLASSROOMS OFTHEORIGINALBUILDINGANDTHE1950S/1960SADDITION,UNISEX RESTROOM,ANDBREAKROOM.(POCHE'DAREASONTHEPLAN). 1950s/1960s ADDITION ORIGINAL CONSTRUCTION

1023SpringdaleRd

LOWROOFBELOW

GUTTERDOWNSPOUTS

CONTINUOUSGUTTER

EXTERIORFACEOF BRICKWALLBELOW

ATLANTA-MILLER GRADESCHOOL

BRICKCHIMNEY, 6PLACES

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24

ArchitexasNo. Date 15February2024 2246

SheetName

RoofPlan

SheetNumber

A-2.11
Bldg11,SuiteE Austin,Texas78721 p512.444.4220
SanAntonio www.architexas.com
AustinDallas
6:12 6:12 6:12 5:12 5:12 5:12 6:12 6:12 6:12 6:12 6:12 6:12 6:12 6:12 6:12
HIP RIDGE HIP HIP HIP
HIP VALLEY HIP VALLEY VALLEY RIDGE RIDGE HIP HIP VALLEY VALLEY VALLEY
RIDGE GABLE RIDGEVENTS SOFFITVENTGRILLSAT EAVES,NOTSHOWN GABLE GABLE HIGHPARAPETWALL 2'-0"TYPICAL OVERHANG 2'-0" TYPICALOVERHANG ROOFBEAM RIDGE RIDGE 1RoofPlan Scale:1/8"=1'-0"
HIP HIP

1061/2W.MillerSt.

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL,

ArchitexasNo. Date 15February2024

SheetName

EnlargedBreakRoomFloorPlan&

A-2.21
InteriorElevations 1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com ATLANTA-MILLER GRADESCHOOL
Atlanta,Texas75551
2246
SheetNumber
PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24 2BreakRoom1-North Scale:3/8"=1'-0" 3BreakRoom1-East Scale:3/8"=1'-0" 5BreakRoom1-West Scale:3/8"=1'-0" 4BreakRoom1-South Scale:3/8"=1'-0" VENEERPLASTER GYP.BD.CEILING SCHED.DR&TRIM SCHED.FLOORING WOODBASE,TYP. 2'-10" SCHEDULED WNDW.TRIM SCHED. WINDOWTRIM SCHED.FLOORING WOODBASE,TYP. VENEERPLASTER GYP.BD.CEILING 3'-6" 2'-10" 1'-6" 27"30"CLR. CLR WOODBASE CABINETS WOODUPPER CABINETS 4"BACKSPLASH 4"BACKSPLASH 1'-6" 3'-6" 3'-6" 2'-10" 1'-6" FREEZERN.I.C. FRIDGE N.I.C. WARM N.I.C. DISH N.I.C. ICE N.I.C. WARM N.I.C. 2 5 3 4 1Room107-EnlargedPlan Scale:3/8"=1'-0" REF N.I.C. DISHN.I.C. 6 EnlargedBreak Room2FloorPlan Scale:3/8"=1'-0" 8BreakRoom2-North Scale:3/8"=1'-0" 7BreakRoom2-East Scale:3/8"=1'-0" 11UnisexRR-South Scale:3/8"=1'-0" 10UnisexRR-West Scale:3/8"=1'-0" 9UnisexRR-North Scale:3/8"=1'-0" GYP.BD.CEILING SCHED.FLOORING EXIST.BRICK FLOOR-MOUNT TOILET TOILETPAPER DISPENSER SEMI-RECESSED PAPERTOWEL DISPENSER/ TRASH ADACOMPLIANT MIRROR ADACOMPLIANT LAVATORY TILEWAINSCOT GRABBARS VENEERPLASTER GYP.BD.CEILING SCHED.FLOORING SCHED.BASE SCHED.FLOORING SCHEDBASE,TYP. GYP.BD.,PAINT GYP.BD.CEILING 3'-6" 2'-10" 1'-6" BASE CABINETS UPPER CABINETS 4"BACKSPLASH REFR. N.I.C. 8 7 9 10 11 18"CLR. 18"CLR. 12" CLR. 36" CLR. FREEZER N.I.C. REFR. N.I.C. WARMER N.I.C. FREEZER N.I.C. WARMER N.I.C. WARMER N.I.C. DW N.I.C. ICE N.I.C. FLOORDRAIN 27"30"CLR. CLR DW N.I.C. 24"CLR. 1x4WD.TRIM, PAINT 1x4WD.TRIM, PAINT

GYP.BD.CEILING

SURFACEMOUNTED

WD.WATERCLOSETS SIMILARTOWOMEN'S R.R.,PAINT

CLEAN.EXIST.MOSAICTILE

ADA-COMPLIANT

SEMI-RECESSED

SURFACEMOUNTTOWEL

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24

ArchitexasNo. Date 15February2024 2246

SheetName

SheetNumber

1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com ATLANTA-MILLER GRADESCHOOL
A-2.22 EnlargedRestroomPlana& InteriorElevations 2 5 3 4 60"x52" 1 EnlargedBreak RoomFloorPlan Scale:3/8"=1'-0" 2Women'sR.R.-West Scale:3/8"=1'-0" 3Women'sR.R.-South Scale:3/8"=1'-0" 4Women'sR.R.-East Scale:3/8"=1'-0" 5Women'sR.R.-North Scale:3/8"=1'-0" 8UnisexR.R.-South Scale:3/8"=1'-0" 7UnisexR.R.-East Scale:3/8"=1'-0" 9Men'sR.R-South Scale:3/8"=1'-0" 10Men'sR.R.-East Scale:3/8"=1'-0" 11Men'sR.R.-West Scale:3/8"=1'-0" 6 EnlargedMen's& UnisexR.R.FloorPlan Scale:3/8"=1'-0" 2 5 3 4 3 4 RESTOREEXISTING PLASTER GYP.BD.CEILING ADACOMPLIANTMIRROR CLEANEXIST. MOSAICTILE ADA-COMPLIANT LAVATORY CLEANEXIST. TILEWAINSCOT SCHED.WATER CLOSET RESTOREEXIST. PLASTER GYP.BD.CEILING,PAINT. CLEANEXIST. MOSAICTILE CLEANEXIST. TILEWAINSCOT ACCESSIBLE WATERCLOSET SCHED.WATER CLOSET ADACOMPLIANT LAVATORY ADACOMPLIANT MIRROR RESTOREDWATER CLOSETS SCHED.ADA COMPLIANT LAVATORY GYP.BD.,PAINT GYP.BD.CEILING SCHED.FLOORING TILEWAINSCOT FLOOR-MOUNT TOILET TOILETPAPER DISPENSER PAPERTOWEL DISPENSER ADACOMPLIANT MIRROR ADACOMPLIANT LAVATORY ADACOMPLIANT MIRROR RESTOREEXIST. PLASTER GYP.BD.CEILING CLEANEXIST. MOSAICTILE CLEANEXIST TILEWAINSCOT RESTOREEXIST. PLASTER
CLEANEXIST. TILEWAINSCOT
FULLHEIGHT MIRROR
LAVATORIES
DISPENSER EXIST.WATER CLOSET,PAINT.
MIRROR&FRAME CLEANEXISTING SOAPHOLDER SURFACEMOUNTED TOWELDISPENSER SOAP RESTOREEXIST.STALLS ACCESSIBLESTALLW/ WOODPARTITION
INSTALLSALVAGED
TOWELDISPENSER TOILETPARITION INFILLTILE@AREA OFMISSINGTILE
TOWELDISPENSER WALLMOUNT SOAP

GENERALNOTES-EXT.ELEV.

1.MASONRYCLEANING A.PRIORTOCLEANINGOFEXTERIORMASONRY,CLEAN&REMOVEDEBRIS (DIRT,BIRDDROPPING,ETC...)FROMEXTERIORSURFACESINCLUDING, BUTNOTLIMITEDTO,BRICK&STONEMASONRY. B.CHEMICALLYCLEANCASTSTONEANDBRICKMASONRY100%.

2.MASONRYRESTORATION: A.SELECTIVELYREPAIRDAMAGEDBRICKMASONRYWHERENOTEDON THEDRAWINGS,WHEREMEPCONDUIT&MISCELLANEOUSDEVICES HAVEBEENREMOVED,ANDWHERELOUVERS&VENTSHAVEBEEN REMOVED.

3.MASONRYMORTARJOINTS:REPOINTBRICK&STONEMORTARJOINTS 100%

4.NORTHENTRY,ADDITION: A.REPLACEENTRYCANOPY,MATCHHISTORICCONFIGURATION.PROVIDE REQUIREDFLASHINGS,SEALANTS,ETC.

5.WINDOWS: A.RESTOREWOODWINDOWASSEMBLIESTHROUGHOUT,REF.WINDOW SCHED.,SHT.A-5.10.

6.DOORS:REF.DOORSCHED.,SHT.A-5.01.

7.SEALANT:REPLACESEALANTATPERIMETEROFDOOR&WINDOW OPENINGS,BETWEENDISSIMILARMATERIALS,&ATMOVEMENTJOINTS.

8.PAINTING: A.WOODWINDOWASSEMBLIES B.WOODDOORASSEMBLIESINCLUDINGEXPOSEDSURFACESOFSTEEL LINTELS.

C.WOODFASCIAANDSOFFIT

9.ROOF:REFERTOSHT.A2.10FOREXTENTOFROOFINGWORK.

ALTERNATES

ALTERNATENO.2:EXTERIORDOORSATADDITION PROVIDEREPLACEMENTWOODDOORSATTHEADDITIONINCLUDING HARDWARE,PAINT.MATCHHISTORICCONFIGURATION.

1061/2W.MillerSt.

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL,

ArchitexasNo. Date 15February2024 2246

SheetName SheetNumber

SouthandWestElevations

A-3.01
Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com
1023SpringdaleRd
ATLANTA-MILLER GRADESCHOOL
Atlanta,Texas75551
F.FLOOR 0'-0" 11'-8" T.O.WALL 11'-8" REMOVE WOOD BRIDGE W/HANDRAIL REMOVEANDREPLACE CANOPY,MATCHHISTORIC CONFIGURATION 6 12 6 12 6 12 5 12 REPLACEMISSINGDOWNSPOUT PROVIDEGRILLE,MATCHHISTORIC EXIST.ASPHALTSHINGLEROOFING REPAIRFASCIAANDSOFFITASREQUIRED,REPAINT REPLACEMETALGUTTERSANDDOWNSPOUTS,TYP. CLEANANDREPOINTBRICK100% EXIST.CRAWLSPACEVENT,TYP. EXIST.GRADE 1WestElevation Scale:1/8"=1'-0" CLEANANDREPOINTBRICKCHIMNEYS,TYP. F.FLOOR 0'-0" 11'-8" T.O.WALL 11'-8"
REPAIRFASCIAANDSOFFITASREQUIRED,REPAINT REPLACEMETALGUTTERSANDDOWNSPOUTS,TYP. REMOVEATTICVENT,RECONSTRUCT WINDOW,MATCHHISTORICCONFIGURATION CLEANANDREPOINTBRICK100% EXIST.CRAWLSPACEVENT,TYP. GRADE 6 12 6 12 6 12 6 12
Scale:1/8"=1'-0" REMOVEVENT,PROVIDEBRICKINFILL RESTOREWOODWINDOWS,TYP. ALTERNATENO.2:PROVIDE REPLACEMENTDOORSAT ADDITION,MATCHHISTORIC CONFIGURATION. RESTOREWOODWINDOWS,TYP. REMOVEVENT,PROVIDEBRICKINFILL REPOINTANDCLEANCASTSTONE 100%,TYP. REPAINTEXTERIORDOORS,TYP.
PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24
EXIST.ASPHALTSHINGLEROOFING
2SouthElevation

CLEANANDREPOINTBRICKCHIMNEYS,TYP. EXIST.ASPHALTSHINGLEROOFING

6 12 6 12 6 12 6 12 5 12 REMOVEWOOD BRIDGE W/HANDRAIL EXIST.ASPHALTSHINGLEROOFING 6 12 6 12 6 12 5 12 CLEANANDREPOINT BRICK100% EXIST.CRAWL SPACEVENT,TYP. EXIST.GRADE F.FLOOR 0'-0" 11'-8" T.O.WALL 11'-8" F.FLOOR 0'-0" 11'-8" T.O.WALL 11'-8" EXIST.TELEPHONEEQUIP. EXIST.ELECTRICALEQUIP. REMOVEANDREPLACECANOPY, MATCHHISTORICCONFIGURATION

1.MASONRYCLEANING A.PRIORTOCLEANINGOFEXTERIORMASONRY,CLEAN&REMOVEDEBRIS (DIRT,BIRDDROPPING,ETC...)FROMEXTERIORSURFACESINCLUDING, BUTNOTLIMITEDTO,BRICK&STONEMASONRY.

B.CHEMICALLYCLEANCASTSTONEANDBRICKMASONRY100%.

2.MASONRYRESTORATION: A.SELECTIVELYREPAIRDAMAGEDBRICKMASONRYWHERENOTEDON THEDRAWINGS,WHEREMEPCONDUIT&MISCELLANEOUSDEVICES HAVEBEENREMOVED,ANDWHERELOUVERS&VENTSHAVEBEEN REMOVED.

3.MASONRYMORTARJOINTS:REPOINTBRICK&STONEMORTARJOINTS 100%

4.NORTHENTRY,ADDITION: A.REPLACEENTRYCANOPY,MATCHHISTORICCONFIGURATION.PROVIDE REQUIREDFLASHINGS,SEALANTS,ETC.

5.WINDOWS: A.RESTOREWOODWINDOWASSEMBLIESTHROUGHOUT,REF.WINDOW SCHED.,SHT.A-5.10.

6.DOORS:REF.DOORSCHED.,SHT.A-5.01.

7.SEALANT:REPLACESEALANTATPERIMETEROFDOOR&WINDOW OPENINGS,BETWEENDISSIMILARMATERIALS,&ATMOVEMENTJOINTS.

8.PAINTING: A.WOODWINDOWASSEMBLIES B.WOODDOORASSEMBLIESINCLUDINGEXPOSEDSURFACESOFSTEEL LINTELS.

C.WOODFASCIAANDSOFFIT

9.ROOF:REFERTOSHT.A2.10FOREXTENTOFROOFINGWORK.

ALTERNATES

ALTERNATENO.2:EXTERIORDOORSATADDITION PROVIDEREPLACEMENTWOODDOORSATTHEADDITIONINCLUDING HARDWARE,PAINT.MATCHHISTORICCONFIGURATION.

AustinDallas

1023SpringdaleRd

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

ArchitexasNo. Date 15February2024 2246

SheetName

SheetNumber

A-3.02
Bldg11,SuiteE Austin,Texas78721 p512.444.4220
NorthandEastElevations SanAntonio www.architexas.com
ATLANTA-MILLER GRADESCHOOL
REPLACEMETALGUTTERSANDDOWNSPOUTS,TYP. EXIST.CRAWLSPACEVENT,TYP. EXIST.GRADE REPAIRFASCIAANDSOFFITASREQUIRED, REPAINT,TYP. REMOVEANDRECONSTRUCT CANOPY,MATCHHISTORIC CONFIGURATION 2NorthElevation Scale:1/8"=1'-0" 1EastElevation Scale:1/8"=1'-0" REPAIRFASCIAANDSOFFITAS REQUIRED,REPAINT REPLACEMETALGUTTERSANDDOWNSPOUTS,TYP. RESTOREWOODWINDOWS,TYP. REMOVEVENT,PROVIDEBRICKINFILL CLEANANDREPOINTBRICK100% RESTOREWOODWINDOWS,TYP. PROVIDEFACEBRICKATEXIST.MASONRYWALL ALTERNATENO.2:PROVIDE REPLACEMENTDOORSAT ADDITION,MATCHHISTORIC CONFIGURATION. REMOVEVENT,PROVIDEBRICKINFILL,TYP.
NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24
GENERALNOTES-EXT.ELEV.

GENERALNOTES-DOORS

1.SCHEDULE: A.HISTORICDOORASSEMBLIESINCLUDINGDOORS,TRANSOMS,FRAMES, CASINGS,TRIM,&HARDWARESHALLBERESTOREDAND/OR REPLICATEDATHISTORICDOORLOCATIONS.THESELOCATIONSARE DENOTEDBY"BOLDFACETYPE"ONTHEDOORSCHEDULE. NON-HISTORICDOORASSEMBLIESSHALLBEPROVIDEDATNEW OPENINGSINHISTORICWALLS&ATNEWWALLSINNON-HISTORIC LOCATIONS.THESELOCATIONSAREDENOTEDBY"PLAINTEXT"ONTHE DOORSCHEDULE.

B.REFERTOGENERALFINISHNOTESONSHT.A6.01FORFINISHING REQUIREMENTS.

2.SURVEY:ASURVEYOFTHEEXISTINGDOORASSEMBLIESSCHEDULEDTO REMAINORSALVAGEDFORRELOCATIONHASBEENCOMPLETED INDICATINGTHESCOPEOFWORKTOTHESEELEMENTS.COMPLETEALL WORKINDICATEDINTHEDETAILEDDOORINVENTORYCONTAINEDINTHE PROJECTMANUAL.

3.HISTORICHARDWARE:

A.EXISTINGHISTORICHARDWARESCHEDULEDTOBEREUSEDSHALL HAVEPAINTORNONHISTORICCOATINGSAND/ORFINISHESREMOVED, BERECONDITIONED&RESTOREDTOWORKINGORDER&HAVEFINISH RESTOREDTOMATCHHISTORIC. B.REPLACEMISSINGORDAMAGEDHARDWAREBEYONDREPAIR, REPLICATEHISTORICHARDWAREATORIGINALDOOROPENING

LOCATIONS.

C.PROVIDEBRASSSCREWSTOMATCHEXISTINGWHEREMISSING& REPLACENON-ORIGINALSCREWSWITHNEWTOMATCHORIGINAL. D.REMOVE&DISPOSENON-HISTORICHARDWAREU.O.N.

4.SOUNDSEAL:PROVIDEPERIMETERSOUNDSEALSATALLMECHANICAL ROOMDOORS.

5.WEATHERSTRIPPING:PROVIDEPERIMETERWEATHERSTRIPPINGATALL EXTERIORDOORS.

6.FIRE-RATEDDOORS:PROVIDEPERIMETERSMOKESEALSATALL FIRE-RATEDDOORS.

7.ADJUSTMENT&FITTING:RE-SECURELOOSEORMISALIGNEDWOODTRIM &CASINGS.RE-SECUREEXISTINGBLOCKING&PROVIDENEWBLOCKING WHERENECESSARYFORTIGHTFITAGAINSTWALLFINISH.

8.DOORBOTTOM:UNDERCUTDOORSIFREQUIREDTOALLOWFORPROPER SWING.EXTENDDOORBOTTOMSMODIFIEDDURINGPRIORALTERATIONS; GAPBETWEENDOORANDTHRESHOLDORFINISHFLOORSHALLNOTBE MORETHAN".

9.SALVAGEDDOORASSEMBLIES: SALVAGED&STOREDDOORASSEMBLIESCURRENTLYLOCATEDINTHE BUILDING.

1061/2W.MillerSt.

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

ArchitexasNo. Date

DOORSCHEDULE&DETAILS

A-5.01
1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com ATLANTA-MILLER GRADESCHOOL
Atlanta,Texas75551
2246
15February2024
PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24 1DoorTypes Scale:3/8"=1'-0" HISTORICWOODDOORW/ WOODPANEL,6LITES,&6-LITE TRANSOM 1950s-1960sADDITIONEXTERIOR HISTORICWOODPAIREDDOORSW/ WOODPANEL AUDITORIUM HISTORICWOODDOORW/3-LITE TRANSOM MAINCORRIDORS/CLASSROOMS HISTORICWOODDOORW/WOOD PANEL MAINCORRIDORS&RESTROOMS B C D E F G H I J K HISTORICWOODPAIREDDOORS W/WOODPANEL,6LITES,& 12-LITETRANSOM 1950s-1960sADDITIONEXTERIOR HISTORICWOODDOORW/ WOODPANEL STORAGECLOSETS RECONSTRUCTREDWOOD DOORW/WOODPANEL ADMIN/ELEC.ROOM RECONSTRUCTEDWOOD DOORW/WOODPANEL 1950s-1960sADDITION HISTORICWOODDOORW/ WOODPANEL 1950s-1960sADDITION ± 7'-0" ± 2'-8" ±3'-6" ± 7'-0" ± 2'-8" ±5'-6" ± 7'-0" ± 7'-0" ± 7'-0" ± 7'-0" ± 7'-0" ± 7'-0" ± 7'-0" ± 6'-8" ±5'-0" ±3'-0" ±3'-0" ±2'-8" ±2'-0" ±2'-7" ±3'-0" ±2'-8" HISTORICWOODPAIREDDOORSW/ WOODPANEL,6LITES,&5-LITE TRANSOM FRONTENTRY A ± 7'-0" ± 2'-10 1/2" ±5'-4" HISTORICWOODDOORW/ WOODPANEL PLUMBINGCLOSETS INTERIOR CASINGTYP. INTERIOR CASINGTYP. INTERIOR CASINGTYP. INTERIOR CASINGTYP. INTERIOR CASINGTYP. INTERIOR CASINGTYP. INTERIOR CASINGTYP. INTERIOR CASINGTYP. L HOLLOWMETALDOOR FIRERATED HALL/OFFICE ± 7'-0" ±2'-8" INTERIOR CASINGTYP. G1 HISTORICWOODDOORW/ WOODPANEL AUDITORIUM ± 7'-0" ±2'-8" INTERIOR CASINGTYP. M.O. M.O. M.O. ± 2" ± 3" ± 3" 116 112 117B 114 111B 108B MATERIAL DOOR 102B 102 DOOR# 100 101 102A 104 TYPE DOORCASING DOORS NEWEXST. HEAD DETAILS HARDWARE THRESHJAMB SETNO. FRAME RATED REMARKS 109 TRANSOM 110A105 106 108 110 NEW 115 103A 103B 117-------103118A--60MIN.123 121 124A 122 120 123A 124 125AA A E G G E F H G1 A G G E F E G G C K B G H H Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood HM Wood Wood Wood WoodGlass WoodGlass Wood 107 F Metal PAIR3'-0"7'-0"1-03/4" 117A G 118 E125 K Wood - B Wood 113 - E Wood 110B - G DOORSIZE (V.I.F.)G 111 - Wood E 111A - Wood G - D Wood 108A - F - E Wood -
SheetName SheetNumber NOTFORREGULATORYAPPROVAL,
DOORSCHEDULE FIRST FLOOR LEVEL CASING EXST. WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass HM Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood Wood WoodINSTALLSALVAGEDDOORASSEMBLYXXX PAIR3'-0"7'-0"1-03/4" PAIR3'-0"7'-0"1-03/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" PAIR2'-6"7'-0"x1-03/4" PAIR2'-6"7'-0"x1-03/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 3'-0"7'-0"x1-3/4" 2'-8"7'-0"x1-3/4" 2'-0"7'-0"x1-3/4" 2'-0"7'-0"x1-3/4" 2'-0"7'-0"x1-3/4" 2'-7"7'-0"x1-3/4"

GENERALNOTES

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

1.100%DD

A-5.10 WINDOWSCHEDULE&DETAILS 1023SpringdaleRd Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com ATLANTA-MILLER GRADESCHOOL
Atlanta,Texas75551
1061/2W.MillerSt.
COPYRIGHT
REVISIONHISTORY
15February2024
Date 15February2024 2246 SheetName SheetNumber
PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24 WINDOWSCHEDULE WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 F I R S T F L O O R L E V E L MATERIAL NO. TYPE WINDOW OPENINGSIZE SILL JAMBHEAD DETAILS NEW REMARKS EXIST. CONDITIONS
ArchitexasNo.
NOTFORREGULATORYAPPROVAL,
1. WOODWINDOWS:RESTOREEXTERIORANDINTERIORWOODWINDOW ASSEMBLIES100%. 2. SEALANTS: A.REMOVE&REPLACEPERIMETERSEALANT100%. 3. WINDOWTREATMENTPROVIDEWOODBLINDSATALLWINDOWS. 4. WINDOWFINISH:REFERTOGENERALNOTES,SHEETA6.01. WoodGlass WoodGlass 3'-91/4"x8'-01/2" A A C A A E E B B1 A B2 A C C E D D A C A C C WoodGlass 123 E 124 125 126 144 143 142 141 140 139 138 137 136 135 134 133 132 131 130 129 128 127 C A C C A A C B1 C E G G G G G G G G G F F WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass WoodGlass 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 3'-91/4"x8'-01/2" 7'-103/4"x8'-01/2" 7'-103/4"x5'-61/2" 7'-103/4"x5'-61/2" 6'-10"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 12'-01/4"x8'-01/2" 17'-61/4"x8'-01/2" 17'-61/4"x8'-01/2" 2'-4"x5'-01/2" 2'-4"x5'-01/2" 2'-4"x5'-01/2" 2'-4"x5'-01/2" 2'-4"x5'-01/2" 2'-0"x2'-0" 2'-0"x2'-0" 3'-4"x2'-10" 3'-4"x2'-10" 3'-4"x2'-10" 3'-4"x2'-10" 3'-4"x2'-10" 3'-4"x2'-10" 3'-4"x2'-10" 3'-4"x2'-10" 3'-4"x2'-10" FIRSTFLOOR xxx 1WindowTypes Scale:1/4"=1'-0" A B B1 B2 C D E F G ± 8'-0 1/2" ± 4'-4 7/8" ±3'-91/4" ± 8'-0 1/2" ± 4'-4 7/8" ±7'-103/4" ±3'-51/4" ±3'-51/4" ±2" ±2" ±81/4" ± 5'-6 1/2" ± 6'-10 7/8" ±7'-103/4" ±3'-51/4" ±3'-51/4" ±2" ±2" ±81/4" ± 8'-0 1/2" ± 4'-4 7/8" ±6'-10" ±2'-103/4" ±2'-103/4" ±21/4" ±21/4" ±8" ± 8'-0 1/2" ± 4'-4 7/8" ±12'-01/4" ±3'-51/4" ±21/4" ±2" ±8" ±3'-51/4" ±8" ±3'-51/4"
8'-0 1/2"
4'-4 7/8" ±17'-61/4" ±21/4" ±21/4" ±8" ±2'-103/4" ±8" ±2'-103/4" ±8" ±2'-103/4" ±8" ±2'-103/4" ±2'-103/4" ± 5'-0 1/2" ± 7'-4 13/16" ±2'-4" ±2" ±2" ±2'-0" ± 2'-0" ± 14'-8 15/16" ±2'-0" ±11/2" ±11/2" ±1'-9" ± 2'-10" ± 7'-1 15/16" ±3'-4" ±2" ±2" ±3'-0" ±3'-51/4" ±2" ±2"
±
±

EXIST.WOOD

EXIST.WOOD

EXIST.WOOD

EXIST.WOOD

EXIST.WOOD

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

ADHEREDACOUSTIC TILE

ADHEREDACOUSTIC TILE

ADHEREDACOUSTIC TILE

GENERALFINISHNOTES

EXIST.WOOD

EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER PLASTER

EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

GYP.BOARD

GYP.BOARD

EXIST.PLASTER/ PLASTER

ADHEREDACOUSTIC TILE

GYP.BOARD

ADHEREDACOUSTIC TILE

GYP.BOARD GYP.BOARD

GYP.BOARD

GYP.BOARD

ADHEREDACOUSTIC TILE

GYP.BOARD

ADHEREDACOUSTIC TILE

ADHEREDACOUSTIC TILE

GYP.BOARD

ADHEREDACOUSTIC TILE

GYP.BOARD

GYP.BOARD

GYP.BOARD

GYP.BOARD

ADHEREDACOUSTIC TILE

1.SURFACES: A.FINISHEXPOSEDSURFACESU.O.N.THECONTRACTORSHALLASSUME FULLRESPONSIBILITYFORTHECOORDINATIONOFTHECOMPLETE FINISH-OUTOFTHEPROJECT.ANYSURFACESWHICHDONOTHAVEA SPECIFICFINISHNOTEDORARENOTEDTOREMAINUNFINISHEDSHALL BEBROUGHTTOTHEATTENTIONOFTHEARCHITECT&FINISHEDPER THEARCHITECT'SINSTRUCTIONS. B.SECURINGOFEXIST.MILLWORK&TRIM:RE-SECUREEXIST.MATERIALS &PLACEINORIGINALPOSITIONORALIGNMENTWHEREMOVEMENTHAS OCCURRED.SECURELOOSEBLOCKING&PROVIDESUPPLEMENTAL BLOCKINGASNECESSARYFORATTACHMENTOFEXIST.&NEW MATERIALS.

C.REFERTOSPEC.SECT.09910A&BPAINTING&FINISHINGFORINTERIOR &EXTERIORFINISH(PAINT)SCHEDULE.

3.RESTOREEXIST.FLOORFINISH: A.WOODFLOORING: (1)REPLACEMISSING,DAMAGED,ORPRIORPOORREPAIRS (2)CLEAN,POLISH,&APPLYSEALER

5.WALLS: A.EXIST.PLASTER:REMOVEDAMAGED&/OR DETERIORATED/DELAMINATINGPLASTERFINISHTOSOUND SUBSTRATE,RE-POINT/RESETMASONRYASNECESSARYTOPROVIDE ASOUNDSUBSTRATE&PROPERKEYFORNEWPLASTER.REPLACE MISSINGORDAMAGEDMETALLATH,REPLACEDAMAGED, DETERIORATED/DELAMINATING,POORLYPATCHED,MISSINGOR NON-MATCHINGPLASTERFINISH.REPAIRCRACKS,HOLES,DEEP GOUGES&INDENTATIONS.PROVIDEASEAMLESSTRANSITION BETWEENNEW&EXIST.PLASTER,FINISHASREQUIREDTOMATCH TEXTUREOFORIGINALSURFACE.

6.CEILING: A.PROVIDEACOUSTICCEILINGTILEORGYP.BOARDCEILING THROUGHOUT.

1023SpringdaleRd

ADHEREDACOUSTIC TILE

GYP.BOARD

ADHEREDACOUSTIC TILE

GYP.BOARD

GYP.BOARD EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER

GYP.BOARD GYP.BOARD GYP.BOARD

GYP.BOARD GYP.BOARD GYP.BOARD

EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER

EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER

GYP.BOARD

GYP.BOARD

GYP.BOARD

ADHEREDACOUSTIC TILE ADHEREDACOUSTIC TILE

ATLANTA-MILLER GRADESCHOOL

1061/2W.MillerSt. Atlanta,Texas75551

COPYRIGHT

TheContractorshallverifyandberesponsible foralldimensions.DONOTscalethedrawing. Anyerrorsoromissionsshallbereportedto Architexaswithoutdelay.TheCopyrightstoall designsanddrawingsarethepropertyof Architexas.Reproductionoruseforanypurpose otherthanthatauthorizedbyArchitexasis forbidden.

REVISIONHISTORY

1.100%DD 15February2024

NOTFORREGULATORYAPPROVAL, PERMITTING,ORCONSTRUCTION ALEXISMCKINNEY,2/15/24

ArchitexasNo. Date 15February2024 2246

SheetName

FINISHSCHEDULE&WALL

SheetNumber

A-6.01
TYPES
Bldg11,SuiteE Austin,Texas78721 p512.444.4220 AustinDallas SanAntonio www.architexas.com
F I R S T F L O O R L E V E L WESTPLUMB.CLS. AUDITORIUM STAGE 108 108A 107 106 WOMEN'SR.R. CLOSET CLASSROOM2103 100 102A 105 104 CLOSET WESTHALL 101 CLASSROOM1 102 EASTHALL 109 CLOSET110A CLASSROOM4 111 ELECTRICALROOM 112 113 114 117 117A BREAKROOM SOUTH WAINSCOT FLOOR BASE NORTH REMARKS WALLS EAST WEST CEILING ROOMNAME RM# 116 CLASSROOM6 118 CLOSET HALL 119 120 BREAKROOM 121 ADA/UNISEXR.R. CLASSROOM5 EASTPLUMB.CLS. NORTHHALL 122 OFFICE 123 OPENOFFICE 125 ADMINISTRATION RESTROOM 110 CLASSROOM3 EXIST.PLASTER/ PLASTER EXIST.PLASTER PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER EXIST.PLASTER/ PLASTER-- EXIST.PLASTER/ PLASTER------CERAMICTILEEXIST.CONCRETE GYP.BOARD FOYER EXIST.WOOD 103ACLOSET115 MEN'SR.R. EXIST.MOSAICTILE OPENOFFICE 124 EXIST.WOODCERAMICTILEEXIST.CONCRETE EXIST.CONCRETE EXIST.CONCRETE EXIST.CONCRETE EXIST.CONCRETE EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD- EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD WOOD EXIST.WOOD EXIST.WOOD
CERAMICTILE CERAMICTILE
EXIST.WOOD
EXIST.WOOD CERAMICTILE MOSAICTILEEXIST.WOODCERAMICTILE
CERAMICTILEEXIST.WOOD
EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD
EXIST.WOOD WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD
EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD EXIST.WOOD
- - - -
- - - -

Turn static files into dynamic content formats.

Create a flipbook