InRow SelfContained Systems Rack integrated cooling system for environmentally controlled spaces.
The IT Closet in a Box…
APC by Schneider Electric – Name – Date
InRow SC Systems Applications Up to 7kW
Wiring Closet/ Server Room • Easily deployable plug and play design • Supplemental cooling for overloaded comfort system
Data Center Hot Spots • Eliminates need
for overcooling • Isolate heat load
APC by Schneider Electric – Name – Date
Converted Spaces • Not designed for IT
equipment • Provides dedicated air conditioning for spaces without cooling
Environmentally Controlled Manufacturing Facilities
• Manufacturing floor
Product/System Overview Rack Air Containment
Configuration 1: Single SC plus NetShelter with Front and Rear Containment (RACSC112/RACSC112E)
InRow SC Configuration 2: Two SC units plus NetShelter with Rear Containment (RACSC201/RACSC201E)
Configuration 3: Single SC plus NetShelter with Rear Containment NetShelter SX
Reference APC AN-114 APC by Schneider Electric – Name – Date
(RACSC101/RACSC101E)
Product / Airflow Heat rejected from condenser coil to plenum space
Air from plenum space pulled into unit via condenser fans
Condenser air absorbs heat from coil Heat transferred to condenser coil
Cool air is supplied to row or room
Reference APC AN-109 APC by Schneider Electric – Name – Date
Hot exhaust air from IT equipment pulled into unit via evaporator fans
Evaporator coil absorbs heat from air
Present the Solution Predictive failure notification Maximizes system availability by providing early warning of required fan or filter replacement
Active Response Controls Monitors and actively adjust cooling capacity to ensure server inlet temperatures
Network manageable View the user interface with a browser. Gives quick access from anywhere on the network
Row-based Architecture Provides increased predictability of cooling performance
Front/Rear Containment Options Ensures cold supply air and server exhaust air does not mix with room air.
Redundant Configuration Available [RACSC201(E)] Systems can be configured to include an additional InRow cooling unit to provide N+1 or 2N redundancy
Noise Dampening [RACSC112(E)] Containment of both front and rear provides reduction of noise caused by Installed equipment
Variable speed fans
Real time capacity monitoring
Variable speed fans reduce energy consumption during off-peak cooling periods.
Measures how much IT load is being cooled by the unit in real time
APC by Schneider Electric – Name – Date
InRow SC Systems User Interface Design Benefits System On Status Light Illuminates green when system is on
Check Log Status Light Illuminates yellow to notify user at least one new alarm condition exists.
Common Interface • Controls common across APC products for intuitive operation
Available Data • Air conditions, alarm set-points, alarm conditions, current mode of operation, system log
Control Functions Warning Status Light Illuminates yellow to notify user of a minor Critical Status alarm condition
Light
Illuminates red when major alarm exists
APC by Schneider Electric – Name – Date
4-Line Alphanumeric Display Provides easy-to-read system status
• Cool set-points, alarm set-points, custom input / output contact definitions
InRow SC Systems Management Design Benefits Real RealTime TimeCapacity CapacityMonitoring Monitoring–– Measure Measurehow howmuch muchIT ITload loadisis being beingcooled cooledby bythe theunit unitin inreal real time. time.
Predictive PredictiveFailure FailureNotification Notification–– Maximizes Maximizessystem systemavailability availabilityby by providing providingearly earlywarning warningof of required requiredfan fanor orfilter filter replacement. replacement.
APC by Schneider Electric – Name – Date
Active ActiveResponse ResponseControls Controls–– Monitors Monitorsand andactively activelyadjust adjust cooling coolingcapacity capacityto toensure ensure server inlet temperatures. server inlet temperatures.
InRow SC Systems Available Services Warranty: One year parts only . If Assembly is purchased, warranty changes to one year parts and labor.
Start Up Services Scheduled assembly and start up service for InRow SC unit and Rack Air Containment.
Preventive Maintenance Services Regular checkups and services can be provided on a monthly, quarterly, or semiannual basis.
On Site Services An APC factory trained technician will arrive on site to diagnose or repair your APC equipment. Includes two scheduled semiannual preventative maintenance visits.
APC by Schneider Electric – Name – Date
InRow SC Systems Options and Related Products Cable Management
InfraStruXure Central
Accessories designed to organize power or data cables within a rack.
Centralized management of your APC network-critical physical infrastructure
Rack Power Distribution Rack-mounted power distribution for networking equipment to high density blade servers.
APC by Schneider Electric – Name – Date
Smart UPS Power protection with scalable runtime for IT equipment .
Reference APC AN-115
InRow SC Systems Summary Rack integrated cooling system for environmentally controlled spaces. ● No need for refrigerant lines or remote heat exchangers. Selfcontained, plug-and-play, design maximize system Agility ● Active Response Controls, network management card, and hotswappable fans dramatically increase system Availability ● Row-based architecture allows close coupling of IT loads with air conditioning units which increases cooling Predictability
The IT Closet in a Box…
APC by Schneider Electric – Name – Date
Security and Environmental Appliances Protects against environmental or human physical threats that cause disruption or downtime to IT assets
NetBotz 200
Environmental Monitoring for Network Closets to Data Centers Rack-mount monitoring for up to 78 external sensors
NetBotz 300
Cost-effective Security and Environmental Monitoring for Network Closets to Data Centers Wall-mount monitoring for up to 4 external sensors and 1 camera
NetBotz 400
Best Value Security and Environmental Monitoring for Network Closets to Data Centers Wall-mount and rack-mount monitoring for up to 18 external sensors and 2 cameras
APC by Schneider Electric – Name – Date
APC NetBotz® Rack Access PX - HID Network appliance enabling remote and local authentication for your NetShelter SX enclosures
Protecting IT Assets From Physical Threats APC by Schneider Electric – Name – Date
Smart-UPS® On-Line High density, double-conversion on-line power protection with scalable runtime
A versatile UPS developed for the harshest power conditions in the world
Smart-UPS On-Line APC by Schneider Electric – Name – Date
Smart-UPS® VT Compact 3-Phase Power Protection with scalable runtime for small data centers and other business critical applications
Over 10 million currently installed – now available in three phase APC by Schneider Electric – Name – Date
Symmetra PX® Right-sized, modular, scalable 3-phase power protection for any size data center or high density power zone.
Ranges:
10-80 kW 25-500 kW
The right-sized UPS for demanding business critical applications Symmetra PX APC by Schneider Electric – Name – Date
Switched Rack PDU Horizontal Mounting Capabilities
Vertical Mounting Capabilities
Mount in any 19” rack or enclosure.
Occupies zero U of valuable rack space; optimized to fit in a NetShelter VX enclosures.
Toolless Mounting Capabilities Quickly and easily mount units in the rear of the enclosure.
Single Input Power Source Single branch models bring up to 3.7 kW to rack. In North America and Japan, multi-branch models bring 12.5 kW to rack via one strip.
Switched Rack PDU APC by Schneider Electric – Name – Date
Remote Individual Outlet Control Turn outlets off that are not in use or recycle power to locked-up equipment.
User Interface Load indicator LED, current monitor, network management
InfraStruXureTM Central End to end data center infrastructure management software for monitoring and control of power, cooling, security and energy usage from the building through IT systems Available in three appliance platforms: Up to 525 devices, up to 2,025 devices, up to 4,025 devices ●Availability •InfraStruXure Central enables an efficient way for organizations to monitor their company-wide multi-vendor physical infrastructure: power, cooling, security, and environment. Real-time monitoring, user-defined reports and graphs, and instant fault notification and escalation enable quick assessment and resolution of critical infrastructure events that can adversely affect IT system availability. ●Agility •Provides a comprehensive look at how the physical and IT environments operate independently and influence each other, providing critical operating information on power and cooling capacity •Total Cost of Ownership •The platforms can grow with changing business needs through additional device licenses and add-on Complete lifecycle, physical location, and surveillance, capacity management and change connectivity of all data center assets management modules. APC by Schneider Electric – Name – Date