Residential Range
Residenzial Range Rev. Date Changes
21/02/2024 First issue
1
MONOSPLIT
Tredis
* Operating limits - (1) Please refer to the table of indoor units for the piping section
Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. - out 7°C d.b. / 6°C w.b.
For the consumption of the system refer to the label of the outdoor
** The width measurement does not include attachments.
Auto restart Silver ion SILVER ION FILTER IONIZER SUPER DC Inverter DC INVERTER Deum A B C AC B A B C
GENERAL DATA TFL26R1 + UNIS26R TFL35R1 + UNIS35R TFL53R1 + UNIS53R TFL70R1 + UNIS70R Cooling capacity kW 2,64 3,52 5,28 6,27 BTU/h 9.000 12.000 18.000 24.000 Power input kW 0,74 1,08 1,55 1,94 Absorbed current A 4,95 5,10 6,7 10,9 S.E.E.R. 6,9 - A++ 7,0 - A++ 7,0 - A++ 6,5 - A++ Heating capacity kW 2,93 3,81 5,42 6,71 BTU/h 10.000 13.000 18.500 22.900 Power input kW 0,78 1,02 1,46 1,80 Absorbed current A 3,5 3,66 6,5 9,3 S.C.O.P. Average 4,0 - A+ 4,1 - A+ 4,0 - A+ 4,0 - A+ INDOOR UNIT TREDIS TFL26R1 TFL35R1 TFL53R1 TFL70R1 Power supply V~,Ph,Hz 230, 1, 50 Air flow m³/h 416/309/230 584/477/395 730/500/420 1020/830/640 Sound power dB(A) 56 55 57 63 Dimensions AxBxC mm 722x290x187 802x297x189 965x319x215 1.080x335x226 Kg kg 7,3 8,6 10,9 13,7 OUTDOOR UNIT TREDIS UNIS26R UNIS35R UNIS53R UNIS70R Compressor Rotary Inverter Power supply V~, Ph, Hz 230, 1, 50 Air flow m³/h 1750 1800 2100 3500 Sound power dB(A) 64 65 65 67 Outdoor temp. * °C (risc) -15 / +50 -15 / +50 -15 / +50 -15 / +50 °C (raff) -15 / +24 -15 / +24 -15 / +24 -15 / +24 Piping lenght m ≤ 25 ≤ 25 ≤ 30 ≤ 30 Diff. in level m ≤ 10 ≤ 10 ≤ 20 ≤ 20 Refrigerant q.ty R32/g 550 550 1100 1450 Gas pipe (1) mm / inch Ф9.53(3/8") Ф9.53(3/8") Ф12.7(1/2") Ф15,9(5/8") Liquid pipe mm / inch Ф6.35(1/4") Ф6.35(1/4") Ф6.35(1/4") Ф9.53(3/8") Dimensions AxBxC ** mm 720x495x270 720x495x270 805x554x330 890x673x324 Kg kg 23,2 23,2 33,5 43,9 Function Super Ioniser Sleep Mode SEER 7.0 Timer Function Variable Speed 3 speeds DC motor Automatic restart Wi-Fi as standard Dehumidification mode Cooling mode Heating mode Filters Silver Ion
3
Lys R3
* Operating limits - (1) Please refer to the table of indoor units for the piping section
Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. - out 7°C d.b. / 6°C w.b.
For the consumption of the system refer to the label of the outdoor
** The width measurement does not include attachments.
Silenziosità Auto restart Compatto Vel. regolabile DC Inverter DC INVERTER Timer Deum A B C AC B A B C
MONOSPLIT
GENERAL DATA LDL26R3 + LDL26R3 LDL35R3 + LDL35R3 LDL53R3 + LDL53R3 LDL70R3 + LDL70R3 Cooling capacity kW 2,64 3,22 5,27 5,86 BTU/h 9.000 11.000 18.000 24.000 Power input kW 0,80 0,99 1,55 1,80 Absorbed current A 3,48 4,3 6,7 7,86 S.E.E.R. 7,0 - A++ 7,1 - A++ 7,4 - A++ 6,1 - A++ Heating capacity kW 2,49 3,52 4,97 6,00 BTU/h 8.500 13.000 19.000 25.000 Power input kW 0,67 0,88 1,29 1,60 Absorbed current A 2,9 3,8 5,64 6,99 S.C.O.P. Average 4,1 - A+ 4,1 - A+ 4,0 - A+ 4,0 - A+ INDOOR UNIT LYS LDL26R3 LDL35R3 LDL53R3 LDL70R3 Power supply V~,Ph,Hz Rotary Inverter Air flow m³/h 230, 1, 50 Sound power dB(A) 50 55 56 59 Dimensions AxBxC mm 715x285x194 805x285x194 957x302x213 1.040x327x220 Kg kg 6,7 7,3 10 12,3 OUTDOOR UNIT LYS LDL26R3 LDL35R3 LDL53R3 LDL70R3 Compressor Rotary Inverter Power supply V~, Ph, Hz 230, 1, 50 Air flow m³/h 1.750 1.750 2.100 3.500 Sound power dB(A) 59 63 63 67 Outdoor temp. * °C (risc) -15 / +50 -15 / +50 -15 / +50 -15 / +50 °C (raff) -20 / +30 -20 / +30 -20 / +30 -20 / +30 Piping lenght m ≤ 25 ≤ 25 ≤ 30 ≤ 50 Diff. in level m ≤ 10 ≤ 10 ≤ 20 ≤ 25 Refrigerant q.ty R32/g 470 520 1080 1420 Gas pipe (1) mm / inch Ф9.53(3/8") Ф9.53(3/8") Ф12.7(1/2") Ф15,9(5/8") Liquid pipe mm / inch Ф6.35(1/4”) Ф6.35(1/4”) Ф6.35(1/4”) Ф9.53(3/8”) Dimensions AxBxC ** mm 720x495x270 720x495x270 805x554x330 890x673x324 Kg kg 21 21 32,7 42,9 Variable Speed Dehumidification mode Sleep Mode 21,5 db(A) Timer Function Cooling mode 3 speeds DC motor Automatic restart Wi-Fi as standard Heating mode Size 26 Compact dimensions 4
B C A B C A Auto restart DC Inverter DC INVERTER Deum Silenziosità Vel. regolabile * Operating limits ** Indoor ventilation side Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. INDOOR UNIT WINDOW AIR CONDITIONER Cooling capacity Absorbed current Power input E.E.R. Compressor Power supply Air flow ** Sound power ** Outdoor temp. * Refrigerant q.ty Dimensions AxBxC Kg MONOBLOCK 3 speeds DC motor Automatic restart Cooling mode Remote control supplied Plug and Play Dehumidification mode Dust-proof function Swing fins SEER 5,2 Silent operation only 46 dB Quick installation 3 ventilation speed
F26A06 kW 70 BTU/h 9.000 A 3,5 kW 0,78 3,45 Rotary Inverter V~, Ph, Hz 230, 1, 50 m³/h 400/360/320 dB(A) 59/57/55 °C +16 / +43 R32 / g 510 mm 560x375x708 kg 43 5
Window Air Conditioner
Complete equipment
The internal units multi Tredis are supplied complete with both infrared remote control for a convenient and direct management of the air conditioner and wireless dongle that allows remote management via App.
Design Aesthetics
The essential and minimalist aesthetics characterised chromatically by a perfect totalwhite, combined with soft lines, allow Tredis to be integrated into any environment.
A B C Auto restart Silver ion SILVER ION FILTER IONIZER SUPER DC Inverter DC INVERTER Deum * Operating limits Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. - out 7°C d.b. / 6°C w.b. Tredis MULTISPLIT INDOOR UNIT TREDIS TFL26R1 TFL35R1 TFL53R1 TFL70R1 Outdoor Multi Residential Outdoor EXT4M80HR Cooling capacity kW 2,64 3,52 5,28 6,27 BTU/h 9.000 12.000 18.000 24.000 Power input kW 0,74 1,08 1,55 1,94 Absorbed current A 4,95 5,10 6,7 10,9 Heating capacity kW 2,93 3,81 5,42 6,71 BTU/h 10.000 13.000 18.500 22.900 Power input kW 0,78 1,02 1,46 1,80 Absorbed current A 3,5 3,66 6,5 9,3 Power supply V~,Ph,Hz 230, 1, 50 Air flow m³/h 416/309/230 584/477/395 730/500/420 1020/830/640 Sound power dB(A) 56 55 57 63 Gas pipe (1) mm / inch Ф9.53(3/8") Ф9.53(3/8") Ф12.7(1/2") Ф15,9(5/8") Liquid pipe mm / inch Ф6.35(1/4") Ф6.35(1/4") Ф6.35(1/4") Ф9.53(3/8") Dimensions AxBxC mm 722x290x187 802x297x189 965x319x215 1.080x335x226 Kg kg 7,3 8,6 10,9 13,7 Sleep Mode Timer Function Variable speed Super Ioniser function SEER 7.0 3 speeds DC motor Automatic restart Wi-Fi as standard Filters Silver Ion Dehumidification mode Cooling mode Heating mode
6
MULTISPLIT
Cassette
Activation contact for renewal air
Renewed aesthetics
The R1 series cassettes are equipped with the new grid panel, which provides increased levels of comfort and aesthetics in line with the other cassette units in the Maxa line.
360° ventilation
The R1 series cassettes are characterised by the round 360° air supply, which increases temperature uniformity in the room.
* Specific only for the indoor unit
A B C F A B C F E D DC Inverter DC INVERTER Segn. Allarmi FRESH On o remoto auto mode
COMMERCIALE
27°C d.b.
19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. - out 7°C d.b. / 6°C w.b.
For the consumption of the system refer to the label of the outdoor Cooling test conditions: in
/
Alarm signalling contact Fan Motor DC
Remote on/off input Auto Mode - Automatic season change Condensate drain pump h max. 75 cm Predisposition WiFi Side air predisposition Predisposition fresh air intake
INDOOR UNIT CASSETTE CCST26R1 CCST35R1 CCST53R1 CCST71R CCST105R (1) CCST105R CCST130R CCST176R Outdoor Multi Residential Outdoor Mono Commercial Cooling capacity kW 2,64 3,51 5,27 7,03 10,55 10,01 14,07 15,24 BTU/h 9.000 12.000 18.000 21.000 33.950 34.160 44.110 53.000 Absorbed current * A 0,50 4,45 7,2 10,2 17,5 6,5 8,1 8,6 Heating capacity kW 2,93 3,80 5,57 7,62 11,14 11,14 16,12 18,17 BTU/h 10.000 13.000 17.870 26.000 38.000 38.000 52.670 62.000 Absorbed current * A 0,50 4,73 6,8 8,50 13,50 5,0 8,00 9,60 Power supply V~, Ph, Hz 230, 1, 50 230, 1, 50 230, 1, 50 230, 1, 50 230, 1, 50 380, 3, 50 380, 3, 50 380, 3, 50 Air flow m³/h 580/500/300 620/510/420 720/620/500 1300/1140/ 1000 1700/1550/ 1380 1700/1550/ 1380 1970/1780/ 1580 2000/1850/ 1650 Sound power dB(A) 59 60 63 67 70 70 73 73 Gas pipe mm / inch Ф9,53(3/8”) Ф9,53(3/8") Ф12,7(1/2") Ф15,9(5/8") Ф15,9(5/8") Ф15,9(5/8") Ф15,9(5/8") Ф15,9(5/8") Liquid pipe mm / inch Ф6,35(1/4”) Ф6,35(1/4") Ф6,35(1/4") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Frame dimensions DxExF mm 570x570x245 647x647x50 647x647x50 830x830x205 830x830x245 830x830x245 830x830x287 830x830x287 Panel dimensions AxBxC mm 647x647x50 570x570x260 570x570x260 950x950x55 950x950x55 950x950x55 950x950x55 950x950x55 Kg kg 14,5 16,3 16,3 21,6 27,2 27,2 29,3 29,3 7
COMMERCIALE MULTISPLIT
Duct
Perfect adaptability
Thanks to the DC technology applied to the fan motors, it is possible to adapt the useful static pressure required for each system using different control curves.
Global control
The ductable series units are equipped as standard with the AIRSET-C wired remote control, which allows global control over every function of the ductable unit and enables it to be connected via a WiFi network.
(*) Value referred to the sum of the absorptions external unit + internal unit (separate supplies) For the consumption of the system refer to the label of the outdoor Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. - out 7°C d.b. / 6°C w.b.
A B C A B C ess. inst. so tto pav m3/h Pa Segn. Allarmi On o remoto auto mode
INDOOR UNIT MULTI DUCT DUCT26R1 DUCT35R1 DUCT53R1 DUCT71R1 DUCT105R1 (1) DUCT105R1 DUCT130R1 DUCT176R1 Outdoor Multi Residential Outdoor Mono Commercial Cooling capacity kW 2,63 3,51 5,27 7,03 10,55 10,55 14,07 15,24 BTU/h 9.000 12.000 18.000 24.000 36.000 36.000 48.000 52.000 Absorbed current * A 1,10 4,75 7,1 10,20 17,50 6,50 8,40 9,60 Heating capacity kW 2,93 3,81 5,57 7,62 11,72 11,72 16,12 18,17 BTU/h 10.000 13.000 19.000 26.000 40.000 38.360 51.280 57.430 Absorbed current * A 1,10 4,52 6,8 9,2 14,5 5,3 8,0 9,5 Power supply V~, Ph, Hz 230, 1, 50 230, 1, 50 230, 1, 50 230, 1, 50 230, 1, 50 380, 3, 50 380, 3, 50 380, 3, 50 Air flow m³/h 500/340/230 600/480/300 911/706.3/515.2 1229/1035/825.1 2100/1800/1500 2100/1800/1500 2400/2040/1680 2600/2210/1820 Ext. Static pressure Pa 0 - 40 0 - 60 0 - 100 0-160 0-160 0-160 0-160 0-160 Sound pressure dB(A) 59 61 65 67 70 70 73 74 Gas pipe mm / inch Ф9.53(3/8") Ф9.53(3/8") Ф12,7(1/2") Ф15,9(5/8") Ф15,9(5/8”) Ф15,9(5/8”) Ф15,9(5/8”) Ф15,9(5/8”) Liquid pipe mm / inch Ф6.35(1/4") Ф6.35(1/4") Ф6.35(1/4") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Dimensions AxBxC mm 700x200x450 700x200x506 880x210x674 1.100x249x774 1.360x249x774 1.360x249x774 1.200x300x874 1.200x300x874 Kg kg 18 17,8 24,4 32,3 40,5 40,5 47,6 47,4
Alarm signalling contact ESP Settings
h max.
Remote on/off input Auto Mode - Automatic season change Condensate drain pump
75 cm
Predisposition renewal air intake
Airset-C wired remote control with WiFi as standard
Activation contact for renewal air
8
MULTISPLIT
COMMERCIALE
Console
Guaranteed efficiency
The console series units are equipped with automatic double opening so that heated or cooled air can be introduced from both the top and bottom, improving comfort.
For the consumption of the system refer to the label of the outdoor
Aesthetics and Design
The renewed intake grid and soft lines that characterise the console series units ensure perfect integration in any environment.
Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. - out 7°C d.b. / 6°C w.b.
Display on board machine Double outlet Air Predisposition WiFi
INDOOR UNIT MULTI CONSOLE CONS35R Outdoor Multi Residential Outdoor Mono Commercial Cooling capacity kW 3,52 BTU/h 12.000 Absorbed current A 4,52 Heating capacity kW 3,81 BTU/h 13.000 Absorbed current A 4,43 Power supply V~, Ph, Hz 230, 1, 50 Air flow m³/h 650/580/490 Sound power dB(A) 54 Gas pipe mm / inch Ф9,53(3/8”) Liquid pipe mm / inch Ф6,35(1/4”) Dimensions AxBxC mm 794x621x206 Kg kg 14,9 9
Floor Ceiling
Ideal for large spaces
The ceiling-floor series units are characterised by generous air flow rates and a large throw distance, these features make them ideal for large spaces.
Flexibility of Installation
The main feature of these units is the possibility of installing them both vertically and horizontally, always ensuring maximum output.
(*) Value referred to the sum of the absorptions external unit + internal unit (separate supplies)
(1) Combined with single-phase outdoor unit Cooling test conditions:
A B C ess. inst. so tto pav Segn. Allarmi On o remoto auto mode COMMERCIALE MULTISPLIT
27°C d.b.
19,5°C w.b. - out 35°C d.b. / 24°C w.b.
Heating
in 20°C d.b. - out 7°C d.b. / 6°C w.b.
in
/
-
test conditions:
MULTISPLIT Alarm signalling contact Flexibility of Installation Remote on/off input Auto Mode Automatic season change Predisposition WiFi
INDOOR UNIT FLOOR CEILING SPV53R SPV71R SPV105R (1) SPV105R SPV130R SPV176R Outdoor Multi Residential Outdoor Mono Commercial Cooling capacity kW 5,27 7,03 10,55 10,55 14,07 15,83 BTU/h 18.000 23.210 34.490 34.430 40.570 54.000 Absorbed current A 6,0 10,54 17,0 6,30 8,8 9,7 Heating capacity kW 5,57 7,62 11,72 11,72 16,12 18,17 BTU/h 19.000 26.000 40.000 39.960 46.100 62.000 Absorbed current A 6,6 9,50 15,00 5,40 8,90 10,50 Power supply V~, Ph, Hz 230, 1, 50 230, 1, 50 230, 1, 50 380, 3, 50 380, 3, 50 380, 3, 50 Air flow m³/h 958/839/723 1192/1023/853 1955/1728/1504 1955/1728/1504 2100/1850/1600 2200/1950/1650 Sound power dB(A) 57 55 64 64 67 67 Gas pipe mm / inch Ф12,7(1/2") Ф15,9(5/8") Ф15,9(5/8") Ф15,9(5/8") Ф15,9(5/8") Ф15,9(5/8") Liquid pipe mm / inch Ф6,35(1/4") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Dimensions AxBxC mm 1.068x675x235 1.068x675x235 1.650x675x235 1.650x675x235 1.650x675x235 1.650x675x235 Kg kg 28 28 41,5 41,5 41,7 42,3 10
MULTISPLIT
Total-One
A Φ504 B H AC B A B C
HEAT RECOVERY OUTDOOR UNIT EXT4M80HR Dimensions (LxPxH) mm 805x330x554 Power supply Ph-V-Hz 1Ph-230V-50Hz Cooling (standard conditions) Capacity Btu/h 27000 W 7912 Input W 2450 Current A 11 EER W/W 3,23 Heating (Standard conditions) Capacity Btu/h 28000 W 8.206 Input W 2210 Current A 10,5 COP W/W 3,71 Seasonal cooling Pdesign kW 7,9 SEER W/W 6,3 Energy efficiency class A++ Seasonal heating (on average) Pdesign kW 6.0 SCOP W/W 4,1 Energy efficiency class A+ Tbiv °C -7 Nominal power input W 5300 Nominal currrent A 24 External air flow m3/h 4000 External sound pressure level dB(A) 61 External sound power level dB(A) 69 Outdoor unit Dimensions (W*D*H) mm 946x410x810 Net kg 64.3 Refrigerant Type R32 GWP 675 Quantity charged kg 1.8 Operative Temperaure Cooling/heating °C -15~50 / -15~24 Refrigerant piping Liquid side/gas side (AC) mm 3x6.35mm / 2x9.52mm +1x12.7mm Max. length for all rooms (AC) m 80(20m for DHW) Max. length for one indoor unit (AC) m 35(20m for DHW) Max. height difference between indoor and outdoor unit (AC) m 15 Max. height difference between indoor units (AC) m 10 DHW CYLINDER INDOR UNITTNK190HR Dimensions AxBxH (mm) 504x574x1660 Operating range Da -15°C a + 43°C Refrigerant connections (mm/”) 6,35 + 9,52 1/4” + 3/8” DHW set point temperature (with heating element enabled) (°C) 38 ~ 55 (70) Tank corrosion protection Magnesium anode Material of construction Enamelled steel Net internal volume Litres 190 Power supply (Ph-V-Hz) 1ph/220~240V/50Hz DHW performance according to EN 16147:2017 Load profile L Nominal power dhwt (kW) 3,9 COP dhw 3,4 DHW test set point (°C) 52 Maximum drawdown with DHW = 40 °C 240 litri Energy class A+ Standby consumption (W) 50 Maximum tank pressure (bar) 10 Protection system Sacrificial magnesium anode Type of material Vitrified steel Integration mode 2kW electric heater COP in DHW production only Air 15°C and DHW from 15°C to 45°C 3,9 Dimensions Dimensions (mm) 1660*504*574 Net weight (kg) 70 Electrical data Electrical wiring 2+Ground Recommended minimum power supply cross-section (mm2) 1,5 Electrical resistance power (kW) 2 Electrical resistance current (A) 9,1 Wiring section to outdoor unit (mm2) 1.0 x 3 + Ground 11
Outdoor Unit
Ф9,53(3/8") Ф9,53(3/8") Ф9,53(3/8") Ф3x9,53+1x12,7 3x3/8"+1 x1/2" Ф3x9,53+1x12,7 3x3/8”+1 x1/2” Ф4x9,53+1x12,7 3x3/8”+1 x1/2”
* Operating limits (1) Please refer to the table of indoor units for the piping section For the consumption of the system refer to the label of the outdoor Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. -
AC B A B C
MULTISPLIT
w.b. Cooling capacity kW BTU/h Power input kW Absorbed current A S.E.E.R. Heating capacity kW BTU/h Power input kW Absorbed current A S.C.O.P. Average S.C.O.P. Warmer Max indoor units Compressor Power supply V~, Ph, Hz Air flow m³/h Sound power dB(A) Outdoor temp. * °C (hea) °C (coo) Refrigerant q.ty R32/g Additional charge g/m Max. length with standard load m Max length for all indoor units m Max length for each unit m Max difference between inside and outside m Diff. in level between indoor units m Gas pipe (1) mm / inch Liquid pipe mm / inch Dimensions AxBxC mm Kg kg EXT2M42R EXT2M53R EXT3M53R EXT3M62R EXT3M80R EXT4M82R EXT4M105R EXT5M120R 4,10 5,27 5,27 6,29 7,91 8,18 10,54 12,30 14.000 18.000 19.000 21.000 27.000 28.000 36.000 42.000 1,27 1,63 1,63 1,95 2,45 2,55 3,81 3,81 5,52 7,10 7,10 9,00 13,70 11,00 15,00 16,00 5,6 - A+ 6.1 - A++ 6.1 - A++ 6.1 - A++ 6,1 - A++ 6,1 - A++ 6,2 - A++ 6,1 - A++ 4,39 5,56 5,27 6,44 8,20 8,79 10,84 12,30 15.000 19.000 18.000 22.000 28.000 30.000 37.000 42.000 1,18 1,39 1,42 1,78 2,10 2,05 2,76 3,30 5,15 6,1 6,2 8,5 12,5 9,0 12,1 14,6 3,8 - A 3,8 - A+ 3,8 - A 4,0 - A+ 4,0 - A+ 3,8 - A 3,8 - A 3,5 - A 4,6 - A++ 5,1 - A+++ 4,6 - A++ 4,8 - A++ 5,1 - A+++ 4,6 - A++ 5,2 - A+++ 5,1 - A+++ 2 2 3 3 3 4 4 5 Rotary Inverter 230, 1, 50 2200 2100 2700 3000 3000 3800 4000 3850 64 65 66 65 67 67 67 69 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 1100 1250 1570 1400 1720 2100 2100 2900 12 12 12 12 12 12 12 12 15 15 15 22,5 22,5 30 30 37,5 40 40 60 60 60 80 80 80 25 25 30 30 30 35 35 35 15 15 15 15 15 15 15 15 10 10 10 10 10 10 10 10 Ф9,53(3/8")
Ф6,53(1/4")
800x554x333 800x554x333 805x554x333 845x702x363 845x702x363 946x810x410 946x810x410 946x810x410 31,8 35,5 36,2 46,8 51,1 62,1 68,8 74,1 12
out 7°C d.b. / 6°C
Ф9,53(3/8")
Ф6,35(1/4") Ф6,35(1/4") Ф6,35(1/4") Ф6,35(1/4") 4x Ф6,35 4x1/4" 4x Ф6,35 4x1/4" 4x Ф6,35 5x1/4"
Outdoor Unit
AC B A B C
COMMERCIAL OUTDOOR UNIT Cooling capacity Heating capacity Compressor Power supply Air flow Sound pressure (1) Outdoor temp. °C (hea) °C (coo) Piping lenght Diff. in level Refrigerant q.ty Gas pipe * Liquid pipe Dimensions AxBxC Kg
Please refer to the table of indoor units for the piping section (1) Operating limits Cooling test conditions: in 27°C d.b. / 19,5°C w.b. - out 35°C d.b. / 24°C w.b. - Heating test conditions: in 20°C d.b. - out 7°C d.b. / 6°C w.b. UECS35R UECS53R UECS71R UECS105R-1 UECS105R UECS130R UECS176R kW 3,51 5,27 7,03 10,55 10,54 14,07 16,11 BTU/h 12.000 18.000 24.000 36.000 36.000 48.000 55.000 kW 3,80 5,56 7,62 11,72 11,72 16,12 18,17 BTU/h 13.000 19.000 26.000 40.000 40.000 55.000 62.000 Rotary Inverter V~, Ph, Hz 230, 1, 50 230, 1, 50 230, 1, 50 230, 1, 50 380, 3, 50 380, 3, 50 380, 3, 50 m³/h 2.200 2.100 3.500 4.000 4000 7.500 7.500 dB(A) 53,6 59 60 63 63 63,5 64 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +50 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 -15 / +24 m 25 30 50 75 75 75 75 m 10 20 25 30 30 30 30 R32/g 720 1150 1500 2400 2400 2900 3000 mm / inch Ф9.53(3/8") Ф12.7(1/2") Ф15.9(5/8") Ф15.9(5/8") Ф15.9(5/8") Ф15.9(5/8") Ф15.9(5/8") mm / inch Ф6.35(1/4") Ф6.35(1/4") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") Ф9.53(3/8") mm 765x555x303 805x554x330 890x673x342 946x810x410 946x810x410 952x1.333x415 952x1.333x415 kg 26,6 32,5 43,9 80,5 66,9 103,7 107 13
*
Turns to water the air-to-air systems and saves space of external unit
A water-cooled unit can be installed in small spaces in the building as long as you have all of the hydraulic connections.
Advantages
The water-cooled unit is useful to solve some difficulties different installation and especially in cases where it is not possible to place the outdoor unit to excessive distance or aesthetic issues or regulatory constraints.
Water cooled units
The water-cooled unit is expected that the external original system drive, single or multi split, is amended as follows:
• Elimination of exchange coils in the air
• Elimination of the fan and the motor
• Inclusion of relevant material suitable to transfer heat or cold water
• Original casing replacement with a more compact and suitable for installations also tight places
Installation
The unit is provided with water connections (inlet and outlet water) refrigerant connections (original) and electrical connections (original).
14
New wire controller Airset R&C
New optional remote control, standard on DUCT models. Depending on the version, it can be connected to Tredis indoor units and to commercial series indoor units.
Versions
AIRSET-R connection to the indoor unit through the SPC accessory
AIRSET-C connection directly to the machine
Main Features
• Two-way communication
• Full control of all features,
• 4.3” LCD
• Backlight
• Weekly programming
• Autorestart
• Integrated Wi-Fi
• NetHome Plus app
15
Via San Giuseppe Lavoratore, 24 - 37040 Arcole - Verona - Italy Tel. (+39) 045 7636585 - P.IVA 01209000239 info@advantixspa.it - www.maxa.it All the information and scripts contained in this catalogue are exclusive property of ADVANTIX SPA. ADVANTIX SPA might have patterns, brands, copyrights or other rights of intellectual property in being or outstanding and covering certain subjects or belonging to some products shown in this catalogue. The possession of this catalogue does not imply the right to use these patterns, brands, copyright or other intellectual properties unless it is allowed by ADVANTIX SPA with a written agreement. ADVANTIX SPA does not assume responsibility for any errors or imprecision in the content of this catalog and reserves the right to make changes to its products any time without notice, according for technical or commercial market needs.