Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
CASTLEC CONSUMER UNIT AND CIRCUIT PROTECTION CATALOGUE The Castlec range of consumer units and circuit protection includes a wide range of electrical products that offer flexible, versatile solutions for a broad range of installations.
OUR CONSUMER UNIT RANGE INCLUDES: • T2 Surge Protection Main Switch Boards • T2 Surge Protection Flexible Dual RCD Boards • Main Switch Boards • RCD Boards
DESIGN FEATURES: • Attractive Curved Lid Design • Tails Clamp • Earth Tag • Spirit Level Fitted
2
DESIGN FEATURES: • Multiple knockouts (top & bottom 25mm, 32mm) Sides 40mm • Glossy White Finish to RAL9001 • Removable & Raised Din Rail • Earth and neutral terminal bars at the top • BS EN61439-3
CIRCUIT PROTECTION DEVICES
AFDDs
RCBOs
TYPE A RCD & TYPE B RCCBs
• Arc Fault Detection Device (AFDD) with RCBO • Range of TYPE A Mini RCBOs • T2 Surge Protection Devices • B & C Curve MCBs
Surge Protection Devices
Main Switch
Bell Transformer
MCBs
Installation Contactors
• TYPE A RCDs 2 Pole & 4 Pole - TYPE B RCCBs 63A 2 pole & 4 pole • 100a Main Switches • Din Rail Bell Transformers • Installation Contactors • Accessories
3
Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
SURGE PROTECTION CONSUMER UNITS PART NO
DESCRIPTION
BOX QTY W
H
D
MCUSPD6
6 Usable Ways Main Switch SPD T2
6
233
252
110
MCUSPD8
8 Usable Ways Main Switch SPD T2
4
280
252
110
MCUSPD10
10 Usable Ways Main Switch SPD T2 4
305
252
110
MCUSPD12
12 Usable Ways Main Switch SPD T2 4
341
252
110
MCUSPD14
14 Usable Ways Main Switch SPD T2 4
377
252
110
MCUSPD16
16 Usable Ways Main Switch SPD T2 4
451
252
110
MCUSPD18
18 Usable Ways Main Switch SPD T2 4
451
252
110
100A MAIN SWITCH SPD BOARD • Fitted with 2 module T2 SPD - suitable for TN, TNC-S, TT systems • BS EN61439-3
PART NO
DESCRIPTION
BOX QTY W
MCUSPD55A 10 Usable Ways Main Switch SPD T2 6
233
DUAL RCD SPD BOARD • 10 Way SPD T2 Fitted with 2 X 100A 30mA RCD’s Type A, 2 Module T2 SPD & Main Switch • BS EN61439-3 • Flexible connection allows for various configurations
4
H
D
252
110
CONSUMER UNITS PART NO
DESCRIPTION
BOX QTY W
H
D
MCUM4
4 Usable Ways Main Switch
8
161
252
110
MCUM6
6 Usable Ways Main Switch
6
197
252
110
MCUM8
8 Usable Ways Main Switch
6
233
252
110
MCUM10
10 Usable Ways Main Switch
6
280
252
110
MCUM12
12 Usable Ways Main Switch
4
305
252
110
MCUM14
14 Usable Ways Main Switch
4
341
252
110
MCUM16
16 Usable Ways Main Switch
4
377
252
110
100A MAIN SWITCH BOARD • Fitted with 100A Main Switch • B S EN61439-3
PART NO
DESCRIPTION
BOX QTY W
H
D
MCUDR44A
8 Usable Ways 2 X 100A RCD & Main Switch
4
305
252
110
MCUDR66A
12 Usable Ways 2 X 100A RCD & Main Switch
4
377
252
110
MCUDR88A
16 Usable Ways 2 X 100A RCD & Main Switch
4
449
252
110
DUAL RCD BOARD • Fitted with 2 x 100A TYPE A RCDs & 100A Main Switch • BS EN61439-3 • Flexible connection allows for various configurations
PART NO
DESCRIPTION
BOX QTY W
H
D
MCUR4
4 Usable Ways 1 X TYPE A 80A RCD
8
161
252
110
MCUR6
6 Usable Ways 1 X TYPE A 80A RCD
4
197
252
110
MCUR8
8 Usable Ways 1 X TYPE A 80A RCD
4
233
252
110
TYPE A RCD BOARDS • Fitted with 80A TYPE A RCD • BS EN61439-3
5
Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
EV AND GARAGE DISTRIBUTION PART NO
DESCRIPTION
BOX QTY W
H
D
ADEVSR32
EV CHARGER UNIT 32A RCBO SPD
6
252
110
161
EV CHARGER DISTRIBUTION Fitted with: • T2 SPD & 32A MCB • 32A RCBO Type A 1P+N Switched • 100A Main Switch
PART NO
DESCRIPTION
BOX QTY W
H
D
MGUO540/16A
40A TYPE A RCD, 1 X 6A & 1 X 16A MCB
12
125
252
110
MGUO563/32A
63A TYPE A RCD, 1 X 6A & 1 X 32A MCB
12
125
252
110
MGUO4/M616
100A MAIN SWITCH , 1 X 6A & 1 X 16A MCB
12
125
252
110
MGUO4/M632
100A MAIN SWITCH , 1 X 6A & 1 X 32A MCB
12
125
252
110
GARAGE UNITS • IP40 Metal Garage Units • TYPE A RCDs • BS EN61439-3
6
MAIN FUSED SWITCHES PART NO
DESCRIPTION
BOX QTY W
H
D
ADMFB100
AC21 100A METAL FUSED MAIN SWITCH (fuse not inc)
6
120
252
110
MAD100FMIS AC22 100A METAL MAIN SWITCH FUSE (c/w 100A Fuse)
6
178
303
108
METAL FUSED MAIN SWITCH • AC Rating : AC21 • Max 100A (Fuses not included) • Tails Clamp • Spirit Level • BS EN61439-3 • Max cable 35mm
METAL FUSED MAIN SWITCH • AC Rating : AC22 • Max 100A c/w 100A fuse • Fuse holder to BSEN60947-3 • Max cable 35mm
PART NO
DESCRIPTION
BOX QTY W
H
D
AD100MS
100A SWITCHFUSE c/w 80A & 100A Fuse
30
78
64
122
FUSED MAIN SWITCH • 100A AC21 • Supplied with 80A & 100A Fuses • Supplied with cable shoud • Max Cable Capacity 35mm
7
Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
ARC FAULT DETECTION DEVICE The latest Edition to the Wiring Regulations BS7671:2018+A2@2022 mandates AFDDs for a select amount of installation types: Higher Risk Residential Buildings (HRRB) Houses in Multiple Occupation (HMO) Purpose-Built Student Accommodation (PBSA) Care homes For all other premises, the use of AFDDs is recommended for single-phase AC final circuits supplying socket-outlets not exceeding 32A.
PART NO
DESCRIPTION
BOX QTY
AFDR6
6A Single Module AFDD with RCBO
30
AFDR10
10A Single Module AFDD with RCBO
30
AFDR16
16A Single Module AFDD with RCBO
30
AFDR20
20A Single Module AFDD with RCBO
30
AFDR32
32A Single Module AFDD with RCBO
30
AFDR40
40A Single Module AFDD with RCBO
30
AFDD WITH RCBO • LED Fault Indication • Type A • Short Circuit Rating 6ka • 1P+N Switched • BS EN62606 & IEC 61009
8
RCBO Current
B Curve
C Curve
6 Amp
RCBO6AMININ
RCBOTCA6MINI
10 Amp
RCBO10AMININ
RCBOTCA10MINI
16 Amp
RCBO16AMININ
RCBOTCA16MINI
20 Amp
RCBO20AMININ
RCBOTCA20MINI
32 Amp
RCBO32AMININ
RCBOTCA32MINI
40 Amp
RCBO40AMININ
RCBOTCA40MINI
RCBO MINI 6KA • Breaking Capacity 6kA • Type A • Single Module Mini Compact Design • BS EN61009-1
Current
B Curve
6 Amp
RCBO1PN6
10 Amp
RCBO1PN10
16 Amp
RCBO1PN16
20 Amp
RCBO1PN20
32 Amp
RCBO1PN32
40 Amp
RCBO1PN40
RCBO MINI 6KA 1P+N SWITCHED • Breaking Capacity 6kA • Type A • Single Module Mini Compact Design • BS EN61009-1 RCBOs that switch both line and neutral, either in the event of a fault or to facilitate maintenance, totally isolate the circuit in question. This provides the occupier with a safe environment while they await the emergency electrician, any fault is completely isolated and all other healthy circuits remain in working order.
9
Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
TYPE A & TYPE B RCDs Current
2 POLE 30mA - TYPE A
25 Amp
RCDA252P30
RCDA254P30
40 amp
RCDA402P30
RCDA404P30
63 Amp
RCDA632P30
RCDA632P100
RCDA634P30
RCDA634P100
80 Amp
RCDA802P30
RCDA802P100
RCDA804P30
RCDA804P100
100 Amp
RCDA1002P30
RCDA1002P100
RCDA1004P30
RCDA1004P100
TIME DELAY 80 Amp
2 POLE 100mA - TYPE A
4 POLE 30mA - TYPE A
RCDA802P100TD
4 POLE 100mA - TYPE A
RCDA804P100TD
TYPE A RCDs • Breaking Capacity 6kA • Type A used to detect AC & DC Pulsating Components • Fastening Torque : 2.0N • BS EN61009-1 • 2 Pole & 4 Pole
Current
2 POLE 30mA TYPE B
4 POLE 30mA TYPE B
63 Amp
RCCB632P30
RCCB634P30
TYPE B RCCBs • Breaking Capacity 6kA • Type B • Fastening Torque : 2.0N • BS EN61009-1 • 2 Pole & 4 Pole Type B residual current circuit breakers (RCCBs) provide total protection for all known residual current faults.They are particularly suited to applications such as: • Electric vehicle charging, where smooth DC fault current >6mA exists • Small scale electricity generating systems such as solar PV and wind generators • Inverters for variable speed control • Uninterruptible power supplies (UPS), and battery chargers • Three phase rectified supplies 10
SURGE PROTECTION AND MCBs PART NO
DESCRIPTION
SPD240N
SPD T2 2 Module c/w cables
SPDMCB32
SPD T2 Single Module , plus 32A MCB & cables
ADSPDCU
Retrofit Surge Protection Unit T2 2 module SPD & Main Switch
T 2 SURGE PROTECTION DEVICES • Suitable for TN, TNC-S, TNC and TT Systems • 20KA - 40KA 18th Edition BS6761 stipulates that Surge Protection Devices are required unless a risk assessment is performed and determines otherwise.
SPD240N
Current
B Curve
C Curve
Box Qty
6 Amp
CAS6MCB
CAS6CMCB
12
10 Amp
CAS10MCB
CAS10CMCB
12
16 Amp
CAS16MCB
CAS16CMCB
12
20 Amp
CAS20MCB
CAS20CMCB
12
32 Amp
CAS32MCB
CAS32CMCB
12
40 Amp
CAS40MCB
CAS40CMCB
12
50 Amp
CAS50MCB
CAS50CMCB
12
63 Amp
CAS63MCB
CAS63CMCB
12
SPDMCB32
ADSPDCU
SINGLE MODULE MCBs • Breaking Capacity 6kA • B Curve & C Curve • Fastening Torque : 2.0N • BS EN60898-1
11
Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
PLASTIC GARAGE UNITS PART NO
DESCRIPTION
BOX QTY W
H
D
GUO540/16A 40A TYPE A RCD, 1 X 6A & 1 X 16A MCB
12
136
183
106
GUO563/32A 63A TYPE A RCD, 1 X 6A & 1 X 32A MCB
12
136
183
106
GUO4/M616
100A Main Switch , 1 X 6A & 1 X 16A MCB
12
136
183
106
GUO4/M632
100A Main Switch , 1 X 6A & 1 X 32A MCB
12
136
183
106
PLASTIC GARAGE UNITS • IP65 Garage Units • TYPE A RCDs • Flame Retardent ABS • BS EN64039-3
PART NO
DESCRIPTION
BOX QTY W
H
D
ADGCUMINI
40A TYPE A RCD, 1 X 6A & 1 X 16A MCB
20
183
106
MINI GARAGE UNITS • IP65 Metal Garage Units • TYPE A RCDs • Flame Retardent ABS • BS EN64039-3 • Ideal for Campervans
12
100
CONTACTORS & AUXILLIARY ITEMS Part No
Description
Modules
MA220PC
20A AC Contactor 2P N/0
1
MA425PC
25A AC Contactor 4P N/0
2
MA240PC
40A AC Contactor 2P N/0
2
MA440PC
40A AC Contactor 4P N/0
3
MA263PC
63A AC Contactor 2P N/0
2
MA463PC
63A AC Contactor 4P N/0
3
MODULAR AC CONTACTORS • BS EN 60948-4-1
Part No
Description
Modules
DTR8
230V 8V Bell Transformer
2
BELL TRANSFORMER • BSEN61558-2
Part No
Description
Modules
CASMS100
100A 2 Pole Main Switch
2
100A MAIN SWITCH • BSEN60947-3
Part No
Description
ADMCBPAD
MCB Padlock
ADCUBL
Plastic Blank (Strip of 5)
ADCUBLM
Metal Blank (Individual)
ACCESSORIES • MCB PADLOCK • PLASTIC AND METAL BLANKS
13
Phone - 01291 431777 Email - sales@castlec.co.uk Website - www.castlec.co.uk
METAL MODULAR ENCLOSURES PART NO DESCRIPTION
BOX QTY W
H
D
MGU3G
3 Module Metal Enclosure
12
125
183
110
MGU4G
4 Module Metal Enclosure
12
125
183
110
TMGU4G 4 Module Metal Enclosure (Tall) 6
125
252
110
MGU6G
6 Module Metal Enclosure
6
161
252
110
MGU8G
8 Module Metal Enclosure
6
197
252
110
MGU12G 12 Module Metal Enclosure
6
269
252
110
IP40 METAL MODULAR ENCLOSURES • Supplied complete with Neutral Cable, Busbar, Neutral & Earth Terminal Bar • Din Rail
PART NO DESCRIPTION
BOX QTY W
H
D
EM220
36
80
145
62
EM220L 2 Module IP20 Enclosure Large 24
80
225
62
EM320
3 Module IP20 Enclosure
24
115
175
62
EM420
4 Module IP20 Enclosure
24
115
175
62
EM420L 4 Module IP20 Enclosure Large 18
115
225
62
2 Module IP20 Enclosure
IP20 METAL DIN RAIL ENCLOSURES
14
PASTIC MODULAR ENCLOSURES PART NO
DESCRIPTION
BOX QTY W
H
D
CT3GN
3 Module IP55 Enclosure
40
180
106
83
IP55 DIN RAIL ENCLOSURES • Earth & Neutral bars fitted • 25mm Top & Bottom Knockouts
PART NO
DESCRIPTION
BOX QTY W
H
D
ADC2-5G
5 Module IP65 Enclosure
30
158
170
105
ADC2-8G
8 Module IP65 Enclosure
20
210
170
105
ADC2-12G
12 Module IP65 Enclosure
15
280
170
105
IP65 DIN RAIL ENCLOSURES • Earth & Neutral bars fitted • Knockouts top, bottom and sides
PART NO
DESCRIPTION
BOX QTY W
H
D
CT2
2 Module IP20 Enclosure
250
50
130
63
CT4
4 Module IP20 Enclosure
100
85
130
63
CT6
6 Module IP20 Enclosure
50
120
130
63
IP20 DIN RAIL ENCLOSURES