The Meridian - 100% DD Set

Page 1

CRP AFFORDABLE HOUSING &

DEVELOPMENT 3941 STEVENS CREEK SANTA CLARA, CA

DEFERRED SUBMITTALS THE FOLLOWING ARE DESIGN-BUILD ITEMS TO BE PROVIDED BY THE CONTRACTOR, AND REQUIRE OUTSIDE ENGINEERING AND SEPARATE SUBMITTALS TO THE BUILDING DEPARTMENT FOR REVIEW AND PERMITTING. SUBMIT ITEMS TO THE CM FOR REVIEW AND APPROVAL PRIOR TO CITY REVIEW. INSTALLATION OF SPRINKLER AND FIRE ALARM SYSTEMS CANNOT START UNTIL A PERMIT HAS BEEN ISSUED BY THE CITY OF SANTA CLARA FIRE DISTRICT AND CITY OF SANTA CLARA. ROOF TRUSSES AND SUPPORT HANGERS FOR TRUSSES FIRE SPRINKLER AND FIRE ALARM SYSTEM • FOR APPLICABLE CODE DATA AND PROJECT DATA INFORMATION SEE SHEET G031 • FOR ADDITIONAL SUPPLEMENTARY INFORMATION SEE 8 1/2" x 11" STRUCTURAL CALCULATION • BY REVIEW OF THESE PLANS, THE GOVERNING AGENCIES CASp REVIEWER HAS DONE A THOROUGH REVIEW AND ANALYSIS AND APPROVAL INDICATES COMPLIANCE UNDER SB1608. FIRE PROTECTION NOTES FIRE SPRINKLER SYSTEM SHALL BE DESIGN BUILD. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL HEAD LOCATIONS WITHIN THE BUILDING, INCLUDING PERMITS AND REQUIRED DRAWINGS BY THE GOVERNING JURISDICTION TO COMPLY WITH ALL APPLICABLE CBC, NFPA, AND LOCAL CODES AND ORDINANCES. PROVIDE SEMI-RECESSED FIRE EXTINGUISHER CABINETS AND FIRE EXTINGUISHERS -75' RUNNING DISTANCE MINIMUM FROM ANY POINT WITHIN THE BUILDING. PAINT CABINET TO MATCH ADJACENT WALL SURFACE. PROVIDE UL LISTED CABINETS WHERE INSTALLED IN RATED WALLS. "JL INDUSTRIES" NO. 1015610 WITH SAF-T-LOK OR APPROVED EQUAL. SOLAR PANELS AND SYSTEM ALL CODE SECTIONS AND FIGURES ARE BASED ON THE 2019 CALIFORNIA BUILDING CODE (T-24) U.O.N. THE DETAILS AND DIAGRAMS ILLUSTRATE THE SPECIFIC REQUIREMENTS & GUIDELINES OF THE ACCESSIBILITY REGULATIONS AND ARE ONLY TO BE USED AS AN AID FOR BUILDING, DESIGN AND CONSTRUCTION. THEY DO NOT REFLECT THE ACTUAL CONDITIONS. REFER TO THE CIVIL AND LANDSCAPE DRAWINGS FOR FURTHER INFORMATION REGARDING SITE. REFER TO THE MECHANICAL, PLUMBING, ELECTRICAL, AND ARCHITECTURAL DRAWINGS FOR GENERAL BUILDING DESIGN REQUIREMENTS. FOR INFORMATION NOT PROVIDED IN DIAGRAMS SEE NOTES ON G3.1G3.4. ACCESSIBILITY NOTES CONTRACTOR NOTES GENERAL CONTRACTOR SHALL COMPLY WITH ALL REQUIREMENTS OF AUTHORITIES HAVING JURISDICTION RELATED TO THE INSTALLATION AND ASSOCIATED REQUIRED TESTS AND INSPECTIONS PRIOR TO COVERING OR CONCEALING THESE MATERIALS. JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 1 : 0 7 P M G001 1648.001 AD/AO Checker TITLE SHEET THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21
MERIDIAN
THE
OWNER APPLICANT CRP AFFORDABLE HOUSING & COMMUNITY DEVELOPMENT 4455 MORENA BLVD., SUITE 107 SAN DIEGO, CA 92117 (619) 993-7581 PHONE CONTACT: STEVEN BLANDEN EMAIL: sblanden@crpaffordable.com ARCHITECT DAHLIN GROUP, INC. ARCHITECT -PLANNERS 5865 OWENS DRIVE PLEASANTON, CA 94588 (925) 251-7200 PHONE (925) 251-7201 FAX CONTACT: LAURI MOFFET-FEHLBERG EMAIL: lfehlberg@dahlingroup.com CIVIL ENGINEER BKF ENGINEERS 4670 WILLOW ROAD, SUITE 250 PLEASANTON, CA 94588 (925) 396-7700 PHONE CONTACT: BROCK ROBY EMAIL: broby@bkf.com ELEMENT STRUCTURAL ENGINEERS, INC. 39675 CEDAR BLVD., SUITE 295C NEWARK, CA 94560 (510) 573-1557PHONE CONTACT: THUY FONTELERA EMAIL: tfontelera@elementse.com MECHANICAL PLUMBING ENGINEER EMERALD CITY ENGINEERS, INC. 21705 HIGHWAY 99 LYNNWOOD, WA 98036 (425) 741-1200 PHONE CONTACT: MASSAMAGHAN KONE EMAIL: mkone@emeraldcityeng.com ELECTRICAL ENGINEER EMERALD CITY ENGINEERS, INC. 21705 HIGHWAY 99 LYNNWOOD, WA 98036 (425) 741-1200 PHONE CONTACT: ADAM FRENCH EMAIL: afrench@emeraldcityeng.com LANDSCAPE ARCHITECT VANDERTOOLEN ASSOCIATES 855 BORDEAUX WAY, SUITE 240 NAPA, CA 94588 (707) 224-2299 PHONE CONTACT: PHIL VANDERTOOLEN EMAIL: phil@vandertoolen.com NO SCALE PROJECT ADDRESS 3941 STEVENS CREEK SANTA CLARA, CA APN#: 294-39-010 STRUCTURAL ENGINEER TRUE NORTH THE WORK OF THIS CONTRACT INCLUDES PROVIDING ALL LABOR, MATERIALS, EQUIPMENT AND SERVICES NECESSARY TO, AND CONSTRUCTION OF A SIX STORY, 59 UNIT APARTMENT BUILDING WITHIN THE 'SCOPE OF WORK' AREA, AND ASSOCIATED SITE WORK FOR UTILITIES AND ACCESSIBILITY IMPROVEMENTS. THE GENERAL CONTRACTOR SHALL THUROUGHLY REVIEW THE PLANS AND SPECIFICATIONS HIM/HERSELF AND WITH ALL TRADES AND ACCEPTS THE MATERIALS, SYSTEMS, DETAILS, AND ASSEMBLIES AS BEING CONSTRUCTIBLE AND CAN BE WARRANTED FOR A TIME PERIOD CONSISTENT WITH INDUSTRY STANDARDS UNLESS A SPECIFIC TIME PERIOD IS NOTED HEREIN. 2019 CALIFORNIA BUILDING CODE (CBC) [2018 INTERNATIONAL BUILDING CODE (IBC)] 2019 CALIFORNIA ELECTRICAL CODE (CEC) [2017 NATIONAL ELECTRICAL CODE (NEC)] 2019 CALIFORNIA MECHANICAL CODE (CMC) [2018 UNIFORM MECHANICAL CODE (UMC)] 2019 CALIFORNIA PLUMBING CODE (CPC) [2018 UNIFORM PLUMBING CODE (UPC)] 2019 CALIFORNIA ENERGY CODE [2019 BUILDING ENERGY EFFICIENCY STANDARDS] 2019 CALIFORNIA FIRE CODE (CFC) [2018 INTERNATIONAL FIRE CODE (IFC)] 2019 CALIFORNIA GREEN BUILDING STANDARDS CODE (CALGreen Code) CITY OF SANTA CLARA, CALIFORNIA MUNICIPAL CODE GENERAL NOTES VICINITY MAP PROJECT IMAGE CODE REFERENCES SCOPE OF WORK SUMMARY CODE ANALYSIS PROJECT DIRECTORY PROJECT DESCRIPTIONTHE MERIDIAN IS A 59-UNIT AFFORDABLE HOUSING DEVELOPMENT LOCATEDAT THE CORNER OF STEVENS CREEK BOULEVARD AND BUCKINGHAM DRIVE IN SANTA CLARA.THIS LARGE FAMILY HOUSING DEVELOPMENT HAS A MIX OF ONE, TWO, THREE, AND FOURBEDROOM UNITS WRAPPED AROUND A CENTRAL PODIUM COURTYARD.OTHER PROJECT AMENITIES INCLUDE A MULTI-PURPOSE COMMUNITY ROOM, INDOOR MAILBOXES, ON-SITE MANAGEMENT OFFICES, SECURED BIKE STORAGE, COMMUNAL LAUNDRY FACILITIES, A TEEN ROOM, AND MULTIPLE ADDITIONAL FLEX SPACES THROUGHOUT.THE MULTI-PURPOSE COMMUNITY ROOM SPILLS OUT ONTO THE PODIUM COURTYARD WHERE PLAY AREAS WILL BE PROVIDED FOR RESIDENTS CONSISTENT WITH CDLAC AND TCAC REQUIREMENTS. THE BUILDING IS SIX STORIES, WITH FIVE STORIES OF RESIDENTIAL UNITS LOCATED OVER GROUND FLOOR GARAGE PARKING AND RESIDENTIAL AMENITY SPACE.THE GROUND FLOOR IS DESIGNED TO HAVE A STRONG STOREFRONT PRESENCE ALONG STEVENS CREEK BOULEVARD.IT WILL BE ACTIVATED BY RESIDENTIAL LOBBY, MAIL, OFFICE AREAS, AND SECURED BIKE STORAGE. THE PROJECT UTILIZES A DENSITY BONUS AND SATISFIES THE TRANSIT ADJACENCY REQUIREMENT UNDER AB1763 WHICH ALLOWS FOR 4 CONCESSIONS, AND A HEIGHT INCREASE OF 33’OR 3 STORIES, AND NO LIMIT ON DENSITY AND DISCRETIONARY WAIVERS ALLOWED BY THE CITY.BASED ON THE CURRENT PROPOSAL, THE PROJECTCOMPLIES WITH THE TRANSIT NEIGHBORHOOD ZONING REGULATIONS AND SEEKS ONLY ONE CONCESSION TO REDUCE THE PARKING REQUIRED FOR THE COMMERCIAL COMPONENT OF THE PROJECT.THE APPLICANT RESERVES THE RIGHT TO APPLY THE REMAINING CONCESSIONS IN THE FUTURE IF DESIRED. REVISIONS
COMMUNITY
WM B F P WM B F P P V C V TRA TE TE LSCP LSCP LSCP LSCP D W Y D W Y COL 8"X8" TYP SIGN CONC S D E W A L K MCU WALL SIDEWALK C O N C 4-5", 1-5" ELECTRICAL JOINT TRENCH (SVP) 55 22 E L E C T R C A L D U C T B A N K ( S V P ) EX 12" C.I. W (CITY OF SANTA CLARA) E X 8 C I W ( C T Y O F S A N T A C L A R A ) E X 6 W EX 4 GAS PG&E) E X 2 G A S ( P G & E ) E X 2 G A S ( P G & E ) EX 4 GAS (PG&E E X 2 G A S ( P G & E ) 2 PVC EB EB EB 2 ARV EB EX SDDI RIM=128.30 X" INV N XX' EX SDDI RIM=128.24 X" INV N XX' SLB UNK 11" EB 3 EB SLB SLB EB EX SDDI RIM=129.71 12" INV IN 125.51' 12" INV OUT 125.31' EX SDDI RIM=130.82 X" INV N XX' EX 12" SD (CITY OF SANTA CLARA) EX SSMH RIM=130.28 X" INV N XX' EX SSMH RIM=130.91 X" INV N XX' EX SSMH RIM=130.95 INV 125.45 EX 8" SS (CITY OF SANTA CLARA) EX 8 SS (C TY OF SANTA C ARA E X 8 S S ( C T Y O F S A N T A C L A R A ) WV WV WV WV WV WV E SS E GV SS SS 1 1 A A 16 16 17 17 B B D D M L L 14 5 2 5' POLE LINE EASEMENT MONUMENT LINE CUT "X" 1.0' OFFSET ON PROPERTY LINE CUT "X" ON TOP OF BLOCK WALL CUT "X" IN SIDEWALK CUT "X" IN SIDEWALK 3/4" IRON PIPE TAGGED L.S. 5907 3/4" IRON PIPE TAGGED L.S. 5907 1. THIS SITE PLAN IS NOT A SURVEY. IT IS PROVIDED FOR BUILDING AND SITE WORK LAYOUT ONLY. THE CONTRACTOR SHALL VERIFY ON SITE ALL GRADES, EXISTING IMPROVEMENTS, PROPERTY LINES, EASEMENTS, SETBACKS, UTILITIES, AND SUBSTRUCTURES WHERE DISCREPANCIES OCCUR, CONTACT ARCHITECT. 2. FINISH GRADE SHALL PROVIDE POSITIVE DRAINAGE AWAY FROM BUILDING. SEE SOILS REPORT FOR ANY SPECIFIC REQUIREMENTS. 3. ALL ROOF DRAINAGE SHALL BE PIPED TO AN APPROVED DRAINAGE FACILITY, S.C.D. 4. IRRIGATION SYSTEM SHALL BE DESIGNED TO PREVENT THE SATURATION OF SOIL ADJACENT TO BUILDING. 5. WHERE DISCREPANCIES BETWEEN SOILS REPORT AND ARCHITECT'S DRAWINGS OCCUR, CONTACT ARCHITECT. 6. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL EXTERIOR CONCRETE SLABS. SPACING OF JOINTS SHALL BE PER INDUSTRY STANDARD, S.L.D. & S.C.D. 7. FOR INFORMATION & SCOPE NOT NOTED SEE CIVIL AND LANDSCAPE DRAWINGS. 8. FOR GENERAL SITE ACCESSIBILITY REQUIREMENT REF. G100 SERIES SHEETS SITE PLAN NOTES STEVENS CREEK BOULEVARD BUCKINGHAM DRIVE TRUE NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 2 : 1 3 P M G110 1648.001 AD/AO Checker CODE COMPLIANCE SITE PLAN THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND SCALE: 1'-0" = 10 20 10' 5 1" = 10'-0" 1 CODE COMPLIANCE SITE PLAN REVISIONS

FACILITIES CALCULATION (833 SF/200 = 4 OCCUPANTS)

ROOM

UP UP 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1. EXIT STAIRWAYS ACCESSED FROM A HORIZONTAL EXIT DO NOT NEED AN AREA OF REFUGE PER CBC SECTION 1009.3 AND PER EXCEPTION 2, DO NOT REQUIRE A CLEAR WIDTH OF 48 INCHES BETWEEN HANDRAILS IN BUILDING EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CBC SECTION 903.3.1.1. OR 903.3.1.2. 2. ELEVATOR IN BUILDING TO COMPLY WITH SECTION 1009.4 AS A PART OF THE ACCESSIBLE MEANS OF EGRESS. 3. ACCESSIBLE PATH OF EGRESS SHALL BE 44" MIN. CLEAR WIDTH THROUGHOUT BUILDING. (36" MIN. IN UNITS AND OTHER AREAS < 10 OCCUPANTS) CBC TABLE 1020.2. 4. STAIRWAYS SHALL BE MIN. 44" WIDE (36" MIN. SERVING AN OCCUPANT LOAD OF LESS THAN 50) PER SEC. 1011.2 AND (CBC 1011.7.1). 5. CARPET IN EXIT ENCLOSURES IS NOT ALLOWED. 6. EXIT DOOR SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND ONLY REQUIRE SINGLE ACTION (1010.1.9 CFC & CBC). EXIT ANALYSIS NOTES I.U. R-2 A.0. OCCUPANCY OCCUPANCY OCCUPANCY ACCESSORY OCCUPANCY TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED WITH NO SEPARATION REQUIRED BETWEEN THE ACCESSORY OCCUPANCY AND THE MAIN OCCUPANCY (CBC 508.2) INCIDENTAL USES TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED (CBC 509.3). REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 509). RESIDENTIAL OCCUPANCY, PER CBC 310.4 REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). M OCCUPANCY MERCANTILE OCCUPANCY PER CBC 309.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). S-2 OCCUPANCY LOW HAZARD STORAGE OCCUPANCY PER CBC 311.3. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). B OCCUPANCY BUSINESS GROUP OCCUPANCY PER CBC 304.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). OCCUPANCY LEGEND EXIT SIGNAGE COMPLYING WITH CBC 1013 & 1143A, SHALL BE PROVIDED WITH THE FOLLOWING TEXTS, SEE PLAN FOR LOCATIONS: A. EXIT B. EXIT STAIR DOWN C. NOT AN EXIT D. EXIT ROUTE E. TO EXIT F. STAIRWAY IDENTIFICATION SIGN, SEE DETAIL 1/-G. FLOOR LEVEL ID SIGN WITHIN STAIRWELL, SEE DETAIL 1/-TEXT BRAILLE 1" HT. # + 60" MAX TO FLOOR BRAILLE EXIT SIGN KEYNOTES EXIT SIGN, S.E.D. KB FE OL ### KNOX BOX UNIT SHALL BE LOCATED ON THE EXTERIOR, RIGHT SIDE OF THE DOOR, BETWEEN FIVE AND SIX FEET ABOVE GROUND. PROVIDE MASTER KEYS AND ACCESS CONTROL CARDS TO OBTAIN ACCESS TO ALL AREAS WITHIN THE BUILDING. IN ADDITION, PROVIDE KEYS NECESSARY TO OPERATE FIRE ALARM CONTROL PANELS, ANNUNCIATORS, RESET OF ALARM DEVICES LOCKS FOR SPRINKLER CONTROL VALVES, PIV, BACK FLOW, ETC. CONTACT THE FIRE DISTRICT FOR APPLICATION AND PURCHASE. ALLOWABLE SF PER OCCUPANT (PER CBC TABLE 1004.1.2) NUMBER OF EXITS REQUIRED (PER CBC 1006.2.1) PANIC INTERIOR ACCESSIBLE PATH OF EGRESS. 10 OR MORE OCCUPANTS 44" MIN. WIDTH; LESS THAN 10 OCCUPANTS 36" MIN. WIDTH (CBC 1119A.3). ACTUAL DISTANCE BETWEEN EXITS PROVIDED. ED EXIT DISCHARGE TO PUBLIC WAY PER CBC 1028 OCCUPANCY TYPE SEMI RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER (2A:10B:C) SEE EXTINGUISHERS SHALL BE MOUNTED ON THE WALL OR IN CABINETS, SUCH THAT THE TOP OF THE EXTINGUISHER IS NO MORE THAN FOUR(4) FEET ABOVE FLOOR LEVEL. EXTINGUISHER SHALL BE COMMERCIAL GRADE, CURRENTLY TAGGED, OR HAVE MANUFACTURER DATE CLEARLY MARKED ON THE EXTINGUISHER. OCCUPANCY EXITING LOAD (ARROW INDICATES DIRECTION OF TRAVEL). EX FR FA PROPERTY LINE 100 R-2 100-01 A FIRE SPRINKLER STANDPIPE VEHICLE STALL ENTRY LINE VEHICLE STALL EXIT LINE ELEVATOR SMOKE GUARD SIGN: "THIS ROOM'S MAXIMUM OCCUPANCY IS _________ PERSONS" PER CBC 1004.3, MOUNT AT 7'-0" (U.O.N) VERIFY LOCATION WITH ARCHITECT. # -NUMBER OF OCCUPANTS EXTERIOR BUILDING SIGNAGE, SEE ELEVATIONS FOR FURTHER INFORMATION DOOR TO BE EQUIPPED WITH PANIC HARDWARE -SEE PROJECT MANUAL AND HARDWARE SCHEDULE FOR MORE INFORMATION. ROOM NAME AND NUMBER SIGNAGE FIRE RATED WINDOW, PER CBC (716.2), SEE WINDOW SCHEDULE SHEETS A7.2 SERIES EMERGENCY EXITING DIAGRAM IN CLEAR PLASTIC HOLDER (8 1/2" x 11" FORMAT). FIRE RISER ROOM SIGNAGE PER CFC 509.1 FIRE ALARM CONTROL PANEL SIGNAGE PER CFC 509.1 DOOR TAG, SEE DOOR SCHEDULE, SHEETS A7.1 SERIES PROPOSED LOCATION OF ANNUNCIATOR PANEL ANNUNCIATOR PANEL IS PART A DEFERRED SUBMITTAL. FINAL PANEL LOCATION SHALL BE DETERMINED AT THE TIME OF SUBMITTAL BY CITY FIRE DEPARTMENT. B ROOM NAME OCCUPANCY TYPE (PER CBC CH. 3) SQUARE FOOTAGE OCCUPANT LOAD DOOR EXITING WIDTH 36" CLR. MAX EXIT CAPACITY 180 CLEAR WIDTH AT DOOR MAXIMUM CAPACITY OF THE EXIT = CLEAR WIDTH 0.2 FACTOR CODE ANALYSIS LEGEND 100 ROOM 1,000 SF EXIT(S) 10 10 ROOM NUMBER RM MD. 1/3 40' - 0" 120'-0" AP 1/3 DE 40'-0" 0" MAXIMUM DIAGONAL DIMENSION OF BUILDING AREA PER CBC SECTION 1007.1.1 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 11,640 SF 59 200 SF/OCC. 2 EXIT(S) S385 SF 2 300 SF/OCC. 1 EXIT(S) I.U. 319 SF 2 300 SF/OCC. 1 EXIT(S) A.0. 193 SF 100 SF/OCC. EXIT(S) B 162 SF 100 SF/OCC. EXIT(S) 57 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 349 SF 2 300 SF/OCC. 1 EXIT(S) A.0. 2,579 SF 43 60 SF/OCC. EXIT(S) M 368 SF 300 SF/OCC. EXIT(S) A.0. 124 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 38 SF 300 SF/OCC. EXIT(S) A.0. 209 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 46 SF 300 SF/OCC. EXIT(S) A.0. ELECTRICAL GARAGE STAIR 1 CORRIDOR ELEVATOR 2 ELEV. EQUIPM. R.R. OFFICE OFFICE BIKE ROOM FLEX SPACE STAIR 2 MECHANICAL MPOE ERRCS FIRE PUMP DUMPSTER ROOM 2 1 1 2 2 1 1 74 SF 300 SF/OCC. EXIT(S) A.0. ELEV. EQUIPM. ELEVATOR 1 G130 1 195-2" MD 1/3 65 -1 195-3 184'-1" 1/3 DE 65'-1" 188'-2" 97-91/2 55'-4" 1/3 DE 32'-7" 55'-5" MD 1/3 32 -7 97-9 G130 2 ED 154 154 ED REQ'D DOOR WIDTH (.2) = 30.8 REQ'D STAIR WIDTH (.3) = 46.2 STAIR 2 TOTAL OCCUPANT LOAD = 154 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" REQ'D DOOR WIDTH (.2) = 30.8 REQ'D STAIR WIDTH (.3) = 46.2 STAIR 1 TOTAL OCCUPANT LOAD = 154 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" 162 REQ'D DOOR WIDTH (.2) = 32.4 TOTAL OCCUPANT LOAD = 162 DOOR WIDTH PROVIDED = 6'-0" ED REQ'D DOOR WIDTH (.2) = 8.6 TOTAL OCCUPANT LOAD = 43 DOOR WIDTH PROVIDED = 6'-0" REQ'D DOOR WIDTH (.2) = 11.8 TOTAL OCCUPANT LOAD = 59 DOOR WIDTH PROVIDED = 3'-0" ED ED ED A524 2 A524 3 A524 1 30 43 30 PLUMBING
COMMUNITY
(GROUP B) PLUMBING FIXTURE REQUIRED PROVIDED MEN WOMEN TOTAL OCCUPANTS WATER CLOSETS URINALS LAVATORIES DRINKING FOUNTAINS 2 2 4 1 1 11 1 1 2 1 2 1 MEN WOMENTOTAL 111 1 1 22 1PLUMBING FACILITIES CALCULATION (356 SF/200 = 2 OCCUPANTS) MANAGER OFFICES/SOCIAL SERVICES ROOM(GROUP B) PLUMBING FIXTURE REQUIRED PROVIDED MEN WOMENTOTAL OCCUPANTS WATER CLOSETS URINALS LAVATORIES DRINKING FOUNTAINS 11 11 1 N/A 1 1 2 N/A MEN WOMENTOTAL 1* N/A 1* N/A* 1* N/A 1 1 2 1* N/A* PER CPC 422.2 EXCEPTION 2, IN OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 10 OR LESS, INCLUDING CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGN FOR USE BY NO MORE THAN ONE PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES. * PER CPC 422.1 THE TOTAL NUMBER OF REQUIRED WATER CLOSETS FOR FEMALES SHALL BE NOT LESS THAN THE TOTAL NUMBER OF REQUIRED WATER CLOSETS AND URINALS FOR MALES. 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 2 : 2 4 P M G121 1648.001 Author Checker CODE COMPLIANCE GROUND FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/8" = 1'-0" 1 GROUND FLOOR -OCCUPANCY PLAN ACCESSORY OCCUPANCY CALCULATIONS PER FLOOR LevelArea Total Floor Area % per Floor BUILDING A GROUND FLOOR1,583 SF18,785 SF 8% BUILDING B 2ND FLOOR T.O.C.201 SF8,158 SF 2% T.O.S.F. 3RD FLOOR296 SF8,111 SF 4% T.O.S.F. 4TH FLOOR92 SF8,111 SF 1% T.O.S.F. 5TH FLOOR296 SF8,111 SF 4% T.O.S.F. 6TH FLOOR296 SF8,111 SF 4% BUILDING C 2ND FLOOR T.O.C.327 SF6,068 SF 5% T.O.S.F. 3RD FLOOR327 SF5,975 SF 5% T.O.S.F. 4TH FLOOR327 SF5,975 SF 5% T.O.S.F. 5TH FLOOR327 SF5,975 SF 5% T.O.S.F. 6TH FLOOR327 SF5,975 SF 5% INCIDENTIAL USE CALCUATIONS PER FLOOR MVArea Total Floor Area % per Floor BUILDING A GROUND FLOOR385 SF18,785 SF 2% BUILDING B 2ND FLOOR T.O.C.400 SF8,158 SF 5% T.O.S.F. 3RD FLOOR195 SF8,111 SF 2% T.O.S.F. 4TH FLOOR400 SF8,111 SF 5% T.O.S.F. 5TH FLOOR195 SF8,111 SF 2% T.O.S.F. 6TH FLOOR195 SF8,111 SF 2% REVISIONS

PLUMBING FACILITIES CALCULATION (833 SF/200 = 4 OCCUPANTS) COMMUNITY ROOM (GROUP B)

REQUIRED PROVIDED

FACILITIES CALCULATION (356 SF/200

REF. REF. REF. REF. REF. REF. REF. REF. REF. DN REF. REF. UP DN UP 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1. EXIT STAIRWAYS ACCESSED FROM A HORIZONTAL EXIT DO NOT NEED AN AREA OF REFUGE PER CBC SECTION 1009.3 AND PER EXCEPTION 2, DO NOT REQUIRE A CLEAR WIDTH OF 48 INCHES BETWEEN HANDRAILS IN BUILDING EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CBC SECTION 903.3.1.1. OR 903.3.1.2. 2. ELEVATOR IN BUILDING TO COMPLY WITH SECTION 1009.4 AS A PART OF THE ACCESSIBLE MEANS OF EGRESS. 3. ACCESSIBLE PATH OF EGRESS SHALL BE 44" MIN. CLEAR WIDTH THROUGHOUT BUILDING. (36" MIN. IN UNITS AND OTHER AREAS < 10 OCCUPANTS) CBC TABLE 1020.2. 4. STAIRWAYS SHALL BE MIN. 44" WIDE (36" MIN. SERVING AN OCCUPANT LOAD OF LESS THAN 50) PER SEC. 1011.2 AND (CBC 1011.7.1). 5. CARPET IN EXIT ENCLOSURES IS NOT ALLOWED. 6. EXIT DOOR SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND ONLY REQUIRE SINGLE ACTION (1010.1.9 CFC & CBC). EXIT ANALYSIS NOTES I.U. R-2 A.0. OCCUPANCY OCCUPANCY OCCUPANCY ACCESSORY OCCUPANCY TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED WITH NO SEPARATION REQUIRED BETWEEN THE ACCESSORY OCCUPANCY AND THE MAIN OCCUPANCY (CBC 508.2) INCIDENTAL USES TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED (CBC 509.3). REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 509). RESIDENTIAL OCCUPANCY, PER CBC 310.4 REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). M OCCUPANCY MERCANTILE OCCUPANCY PER CBC 309.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). S-2 OCCUPANCY LOW HAZARD STORAGE OCCUPANCY PER CBC 311.3. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). B OCCUPANCY BUSINESS GROUP OCCUPANCY PER CBC 304.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). OCCUPANCY LEGEND EXIT SIGNAGE COMPLYING WITH CBC 1013 & 1143A, SHALL BE PROVIDED WITH THE FOLLOWING TEXTS, SEE PLAN FOR LOCATIONS: A. EXIT B. EXIT STAIR DOWN C. NOT AN EXIT D. EXIT ROUTE E. TO EXIT F. STAIRWAY IDENTIFICATION SIGN, SEE DETAIL 1/-G. FLOOR LEVEL ID SIGN WITHIN STAIRWELL, SEE DETAIL 1/-TEXT BRAILLE 1" HT. + 60" MAX TO FLOOR BRAILLE EXIT SIGN KEYNOTES EXIT SIGN, S.E.D. KB FE OL ### KNOX BOX UNIT SHALL BE LOCATED ON THE EXTERIOR, RIGHT SIDE OF THE DOOR, BETWEEN FIVE AND SIX FEET ABOVE GROUND. PROVIDE MASTER KEYS AND ACCESS CONTROL CARDS TO OBTAIN ACCESS TO ALL AREAS WITHIN THE BUILDING. IN ADDITION, PROVIDE KEYS NECESSARY TO OPERATE FIRE ALARM CONTROL PANELS, ANNUNCIATORS, RESET OF ALARM DEVICES LOCKS FOR SPRINKLER CONTROL VALVES, PIV, BACK FLOW, ETC. CONTACT THE FIRE DISTRICT FOR APPLICATION AND PURCHASE. ALLOWABLE SF PER OCCUPANT (PER CBC TABLE 1004.1.2) NUMBER OF EXITS REQUIRED (PER CBC 1006.2.1) PANIC INTERIOR ACCESSIBLE PATH OF EGRESS. 10 OR MORE OCCUPANTS 44" MIN. WIDTH; LESS THAN 10 OCCUPANTS 36" MIN. WIDTH (CBC 1119A.3). ACTUAL DISTANCE BETWEEN EXITS PROVIDED. ED EXIT DISCHARGE TO PUBLIC WAY PER CBC 1028 OCCUPANCY TYPE SEMI RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER (2A:10B:C) SEE EXTINGUISHERS SHALL BE MOUNTED ON THE WALL OR IN CABINETS, SUCH THAT THE TOP OF THE EXTINGUISHER IS NO MORE THAN FOUR(4) FEET ABOVE FLOOR LEVEL. EXTINGUISHER SHALL BE COMMERCIAL GRADE, CURRENTLY TAGGED, OR HAVE MANUFACTURER DATE CLEARLY MARKED ON THE EXTINGUISHER. OCCUPANCY EXITING LOAD (ARROW INDICATES DIRECTION OF TRAVEL). EX X FR FA PROPERTY LINE 100 R-2 100-01 A FIRE SPRINKLER STANDPIPE VEHICLE STALL ENTRY LINE VEHICLE STALL EXIT LINE ELEVATOR SMOKE GUARD SIGN: "THIS ROOM'S MAXIMUM OCCUPANCY IS _________ PERSONS" PER CBC 1004.3, MOUNT AT 7'-0" (U.O.N) VERIFY LOCATION WITH ARCHITECT. -NUMBER OF OCCUPANTS EXTERIOR BUILDING SIGNAGE, SEE ELEVATIONS FOR FURTHER INFORMATION DOOR TO BE EQUIPPED WITH PANIC HARDWARE -SEE PROJECT MANUAL AND HARDWARE SCHEDULE FOR MORE INFORMATION. ROOM NAME AND NUMBER SIGNAGE FIRE RATED WINDOW, PER CBC (716.2), SEE WINDOW SCHEDULE SHEETS A7.2 SERIES EMERGENCY EXITING DIAGRAM IN CLEAR PLASTIC HOLDER (8 1/2" x 11" FORMAT). FIRE RISER ROOM SIGNAGE PER CFC 509.1 FIRE ALARM CONTROL PANEL SIGNAGE PER CFC 509.1 DOOR TAG, SEE DOOR SCHEDULE, SHEETS A7.1 SERIES PROPOSED LOCATION OF ANNUNCIATOR PANEL ANNUNCIATOR PANEL IS PART A DEFERRED SUBMITTAL. FINAL PANEL LOCATION SHALL BE DETERMINED AT THE TIME OF SUBMITTAL BY CITY FIRE DEPARTMENT. B ROOM NAME OCCUPANCY TYPE (PER CBC CH. 3) SQUARE FOOTAGE OCCUPANT LOAD DOOR EXITING WIDTH 36" CLR. MAX EXIT CAPACITY 180 CLEAR WIDTH AT DOOR MAXIMUM CAPACITY OF THE EXIT = CLEAR WIDTH 0.2 FACTOR CODE ANALYSIS LEGEND 100 ROOM 1,000 SF 1 EXIT(S) 10 10 ROOM NUMBER RM MD. 1/3 40' - 0" 120'-0" AP 1/3 DE 40'-0" 0" MAXIMUM DIAGONAL DIMENSION OF BUILDING AREA PER CBC SECTION 1007.1.1 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND JANITOR TRASH UNIT 2B BIKE ROOM ELEVATOR 1 STORAGE COMMUNITY ROOM UNIT 1A UNIT 2A R.R. IDF MAINTENANCE UNIT 2B UNIT 3A UNIT 4A STAIR 2 UNIT 2A UNIT 3A UNIT 3A UNIT 1B UNIT 3A STAIR 1 ELEVATOR 2 92 SF 300 SF/OCC. EXIT(S) A.0. 195 SF 300 SF/OCC. EXIT(S) I.U. 1,106 SF 6 200 SF/OCC. 1 EXIT(S) R846 SF 200 SF/OCC. EXIT(S) R205 SF 300 SF/OCC. EXIT(S) I.U. 612 SF 4 200 SF/OCC. 1 EXIT(S) R1,080 SF 200 SF/OCC. EXIT(S) R1,057 SF 200 SF/OCC. EXIT(S) -2 833 SF 100 SF/OCC. EXIT(S) B 802 SF 5 200 SF/OCC. 1 EXIT(S) R546 SF 200 SF/OCC. EXIT(S) R-2 830 SF 5 200 SF/OCC. 1 EXIT(S) R846 SF 200 SF/OCC. EXIT(S) -2 1,111 SF 200 SF/OCC. 1 EXIT(S) R-2 1,318 SF 200 SF/OCC. EXIT(S) R-2 6 1 1 6 9 3 5 5 1 5 109 SF 300 SF/OCC. 1 EXIT(S) A.0. 62 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 169 SF 300 SF/OCC. EXIT(S) A.0. 61 SF 300 SF/OCC. EXIT(S) A.0. D E A D E N D C O R R D O R L E N G T H 49'-10" DEAD E ND CORRIDOR LENGTH 43'-10" R.R. 35 SF 300 SF/OCC. EXIT(S) A.0. 3,452 SF 231 15 SF/OCC. EXIT(S) 116 116 REQ'D DOOR WIDTH (.2) = 30.8 REQ'D STAIR WIDTH (.3) = 46.2 STAIR 2 TOTAL OCCUPANT LOAD = 154 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" 154 154 REQ'D DOOR WIDTH (.2) = 30.8 REQ'D STAIR WIDTH (.3) = 46.2 STAIR 1 TOTAL OCCUPANT LOAD = 154 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" REQ'D DOOR WIDTH (.2) = 14.8 TOTAL OCCUPANT LOAD = 74 DOOR WIDTH PROVIDED = 3'-0" REQ'D DOOR WIDTH (.2) = 16 TOTAL OCCUPANT LOAD = 80 DOOR WIDTH PROVIDED = 3'-0" G130 1 WEST CORRIDOR EAST CORRIDOR 48'-8"1/3 DE 40'-1" 48'-8" 98'-0 1/2" 1/3 DE 53'-5" 98'-0 1/2" 120-21/2 MD 1/3 401 " 120-3 " 1 160-3MD 1/3 53 -5 160-3 G130 2 REQUIRED REFUGE AREA PER CBC 1026.4 159 OCCUPANTS + 148 OCCUPANTS = 307 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 180 OCCUPANTS x 3 SQFT = 540 SQFT REQUIRED REQUIRED REFUGE AREA PER CBC 1026.4 159 OCCUPANTS + 148 OCCUPANTS = 307 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 180 OCCUPANTS x 3 SQFT = 540 SQFT REQUIRED REQ'D DOOR WIDTH (.2) = 23.2 TOTAL OCCUPANT LOAD = 116 DOOR WIDTH PROVIDED = 3'-0" REQ'D DOOR WIDTH (.2) = 23.2 TOTAL OCCUPANT LOAD = 116 DOOR WIDTH PROVIDED = 3'-0" A524 A524 1 A524 4
PLUMBING FIXTURE
MEN WOMENTOTAL OCCUPANTS WATER CLOSETS URINALS LAVATORIES DRINKING FOUNTAINS 224 11 11 1 1 2 1 2 1 MEN WOMENTOTAL 111 1 1 22 1 -
= 2 OCCUPANTS) MANAGER OFFICES/SOCIAL SERVICES ROOM(GROUP B) PLUMBING FIXTURE REQUIRED PROVIDED MEN WOMENTOTAL OCCUPANTS WATER CLOSETS URINALS LAVATORIES DRINKING FOUNTAINS 11 11 1 N/A 1 1 2 N/A MEN WOMENTOTAL 1* N/A 1* N/A* 1* N/A 1 1 2 1* N/A* * PER CPC 422.2 EXCEPTION 2, IN OCCUPANCIES WITH A TOTAL OCCUPANT LOAD OF 10 OR LESS, INCLUDING CUSTOMERS AND EMPLOYEES, ONE TOILET FACILITY, DESIGN FOR USE BY NO MORE THAN ONE PERSON AT A TIME, SHALL BE PERMITTED FOR USE BY BOTH SEXES. PER CPC 422.1 THE TOTAL NUMBER OF REQUIRED WATER CLOSETS FOR FEMALES SHALL BE NOT LESS THAN THE TOTAL NUMBER OF REQUIRED WATER CLOSETS AND URINALS FOR MALES. 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 2 : 3 6 P M G122 1648.001 AD/AO Checker CODE COMPLIANCE SECOND FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/8" = 1'-0" 1 2ND FLOOR -OCCUPANCY PLAN ACCESSORY OCCUPANCY CALCULATIONS PER FLOOR LevelArea Total Floor Area % per Floor BUILDING A GROUND FLOOR1,583 SF18,785 SF 8% BUILDING B 2ND FLOOR T.O.C.201 SF8,158 SF 2% T.O.S.F. 3RD FLOOR296 SF8,111 SF 4% T.O.S.F. 4TH FLOOR92 SF8,111 SF 1% T.O.S.F. 5TH FLOOR296 SF8,111 SF 4% T.O.S.F. 6TH FLOOR296 SF8,111 SF 4% BUILDING C 2ND FLOOR T.O.C.327 SF6,068 SF 5% T.O.S.F. 3RD FLOOR327 SF5,975 SF 5% T.O.S.F. 4TH FLOOR327 SF5,975 SF 5% T.O.S.F. 5TH FLOOR327 SF5,975 SF 5% T.O.S.F. 6TH FLOOR327 SF5,975 SF 5% INCIDENTIAL USE CALCUATIONS PER FLOOR MVArea Total Floor Area % per Floor BUILDING A GROUND FLOOR385 SF18,785 SF 2% BUILDING B 2ND FLOOR T.O.C.400 SF8,158 SF 5% T.O.S.F. 3RD FLOOR195 SF8,111 SF 2% T.O.S.F. 4TH FLOOR400 SF8,111 SF 5% T.O.S.F. 5TH FLOOR195 SF8,111 SF 2% T.O.S.F. 6TH FLOOR195 SF8,111 SF 2% REVISIONS
PLUMBING
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1. EXIT STAIRWAYS ACCESSED FROM A HORIZONTAL EXIT DO NOT NEED AN AREA OF REFUGE PER CBC SECTION 1009.3 AND PER EXCEPTION 2, DO NOT REQUIRE A CLEAR WIDTH OF 48 INCHES BETWEEN HANDRAILS IN BUILDING EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CBC SECTION 903.3.1.1. OR 903.3.1.2. 2. ELEVATOR IN BUILDING TO COMPLY WITH SECTION 1009.4 AS A PART OF THE ACCESSIBLE MEANS OF EGRESS. 3. ACCESSIBLE PATH OF EGRESS SHALL BE 44" MIN. CLEAR WIDTH THROUGHOUT BUILDING. (36" MIN. IN UNITS AND OTHER AREAS < 10 OCCUPANTS) CBC TABLE 1020.2. 4. STAIRWAYS SHALL BE MIN. 44" WIDE (36" MIN. SERVING AN OCCUPANT LOAD OF LESS THAN 50) PER SEC. 1011.2 AND (CBC 1011.7.1). 5. CARPET IN EXIT ENCLOSURES IS NOT ALLOWED. 6. EXIT DOOR SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND ONLY REQUIRE SINGLE ACTION (1010.1.9 CFC & CBC). EXIT ANALYSIS NOTES I.U. R-2 A.0. OCCUPANCY OCCUPANCY OCCUPANCY ACCESSORY OCCUPANCY TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED WITH NO SEPARATION REQUIRED BETWEEN THE ACCESSORY OCCUPANCY AND THE MAIN OCCUPANCY (CBC 508.2) INCIDENTAL USES TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED (CBC 509.3). REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 509). RESIDENTIAL OCCUPANCY, PER CBC 310.4 REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). M OCCUPANCY MERCANTILE OCCUPANCY PER CBC 309.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). S-2 OCCUPANCY LOW HAZARD STORAGE OCCUPANCY PER CBC 311.3. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). B OCCUPANCY BUSINESS GROUP OCCUPANCY PER CBC 304.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). OCCUPANCY LEGEND EXIT SIGNAGE COMPLYING WITH CBC 1013 & 1143A, SHALL BE PROVIDED WITH THE FOLLOWING TEXTS, SEE PLAN FOR LOCATIONS: A. EXIT B. EXIT STAIR DOWN C. NOT AN EXIT D. EXIT ROUTE E. TO EXIT F. STAIRWAY IDENTIFICATION SIGN, SEE DETAIL 1/-G. FLOOR LEVEL ID SIGN WITHIN STAIRWELL, SEE DETAIL 1/-TEXT BRAILLE 1" HT. + 60" MAX TO FLOOR BRAILLE EXIT SIGN KEYNOTES EXIT SIGN, S.E.D. KB FE OL ### KNOX BOX UNIT SHALL BE LOCATED ON THE EXTERIOR, RIGHT SIDE OF THE DOOR, BETWEEN FIVE AND SIX FEET ABOVE GROUND. PROVIDE MASTER KEYS AND ACCESS CONTROL CARDS TO OBTAIN ACCESS TO ALL AREAS WITHIN THE BUILDING. IN ADDITION, PROVIDE KEYS NECESSARY TO OPERATE FIRE ALARM CONTROL PANELS, ANNUNCIATORS, RESET OF ALARM DEVICES LOCKS FOR SPRINKLER CONTROL VALVES, PIV, BACK FLOW, ETC. CONTACT THE FIRE DISTRICT FOR APPLICATION AND PURCHASE. ALLOWABLE SF PER OCCUPANT (PER CBC TABLE 1004.1.2) NUMBER OF EXITS REQUIRED (PER CBC 1006.2.1) PANIC INTERIOR ACCESSIBLE PATH OF EGRESS. 10 OR MORE OCCUPANTS 44" MIN. WIDTH; LESS THAN 10 OCCUPANTS 36" MIN. WIDTH (CBC 1119A.3). ACTUAL DISTANCE BETWEEN EXITS PROVIDED. ED EXIT DISCHARGE TO PUBLIC WAY PER CBC 1028 OCCUPANCY TYPE SEMI RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER (2A:10B:C) SEE EXTINGUISHERS SHALL BE MOUNTED ON THE WALL OR IN CABINETS, SUCH THAT THE TOP OF THE EXTINGUISHER IS NO MORE THAN FOUR(4) FEET ABOVE FLOOR LEVEL. EXTINGUISHER SHALL BE COMMERCIAL GRADE, CURRENTLY TAGGED, OR HAVE MANUFACTURER DATE CLEARLY MARKED ON THE EXTINGUISHER. OCCUPANCY EXITING LOAD (ARROW INDICATES DIRECTION OF TRAVEL). EX X FR FA PROPERTY LINE 100 R-2 100-01 A FIRE SPRINKLER STANDPIPE VEHICLE STALL ENTRY LINE VEHICLE STALL EXIT LINE ELEVATOR SMOKE GUARD SIGN: "THIS ROOM'S MAXIMUM OCCUPANCY IS _________ PERSONS" PER CBC 1004.3, MOUNT AT 7'-0" (U.O.N) VERIFY LOCATION WITH ARCHITECT. -NUMBER OF OCCUPANTS EXTERIOR BUILDING SIGNAGE, SEE ELEVATIONS FOR FURTHER INFORMATION DOOR TO BE EQUIPPED WITH PANIC HARDWARE -SEE PROJECT MANUAL AND HARDWARE SCHEDULE FOR MORE INFORMATION. ROOM NAME AND NUMBER SIGNAGE FIRE RATED WINDOW, PER CBC (716.2), SEE WINDOW SCHEDULE SHEETS A7.2 SERIES EMERGENCY EXITING DIAGRAM IN CLEAR PLASTIC HOLDER (8 1/2" x 11" FORMAT). FIRE RISER ROOM SIGNAGE PER CFC 509.1 FIRE ALARM CONTROL PANEL SIGNAGE PER CFC 509.1 DOOR TAG, SEE DOOR SCHEDULE, SHEETS A7.1 SERIES PROPOSED LOCATION OF ANNUNCIATOR PANEL ANNUNCIATOR PANEL IS PART A DEFERRED SUBMITTAL. FINAL PANEL LOCATION SHALL BE DETERMINED AT THE TIME OF SUBMITTAL BY CITY FIRE DEPARTMENT. B ROOM NAME OCCUPANCY TYPE (PER CBC CH. 3) SQUARE FOOTAGE OCCUPANT LOAD DOOR EXITING WIDTH 36" CLR. MAX EXIT CAPACITY 180 CLEAR WIDTH AT DOOR MAXIMUM CAPACITY OF THE EXIT = CLEAR WIDTH 0.2 FACTOR CODE ANALYSIS LEGEND 100 ROOM 1,000 SF 1 EXIT(S) 10 10 ROOM NUMBER RM MD. 1/3 40' - 0" 120'-0" AP 1/3 DE 40'-0" 0" MAXIMUM DIAGONAL DIMENSION OF BUILDING AREA PER CBC SECTION 1007.1.1 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND JANITOR TRASH UNIT 2B UNIT 3A LAUNDRY ELEVATOR 1 UNIT 1B ELEVATOR 2 UNIT 3A UNIT 3A UNIT 3A UNIT 1A UNIT 2A UNIT 2A TEEN ROOM STAIR 2 UNIT 4A UNIT 2B UNIT 3A 92 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 195 SF 1 300 SF/OCC. EXIT(S) I.U. 1,083 SF 200 SF/OCC. EXIT(S) -2 846 SF 200 SF/OCC. EXIT(S) R-2 205 SF 300 SF/OCC. EXIT(S) A.0. 590 SF 200 SF/OCC. EXIT(S) R1,080 SF 200 SF/OCC. EXIT(S) R-2 1,057 SF 6 200 SF/OCC. 1 EXIT(S) R1,085 SF 200 SF/OCC. EXIT(S) R- 802 SF 5 200 SF/OCC. 1 EXIT(S) R545 SF 200 SF/OCC. EXIT(S) R-2 808 SF 5 200 SF/OCC. 1 EXIT(S) R291 SF 300 SF/OCC. EXIT(S) A.0. 846 SF 200 SF/OCC. EXIT(S) R-2 1,084 SF 6 200 SF/OCC. 1 EXIT(S) R1,304 SF 200 SF/OCC. EXIT(S) -2 5 5 5 DEAD E ND CORRIDOR LENGTH 49'-10" DEAD E ND CORRIDOR LENGTH 43'-10" REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 2 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" 34 REQ'D DOOR WIDTH (.2) = 3 TOTAL OCCUPANT LOAD = 15 DOOR WIDTH PROVIDED = 3'-0" 34 REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 1 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" STAIR 1 35 SF 300 SF/OCC. EXIT(S) A.0. IDF REQ'D DOOR WIDTH (.2) = 3.8 TOTAL OCCUPANT LOAD = 19 DOOR WIDTH PROVIDED = 3'-0" G130 1 WEST CORRIDOR EAST CORRIDOR 120-21/2 MD 1/3 401 120-3 160-3 48'-8" MD 1/3 53 -5" 160-3" 1/3 DE 40'-1" 48'-8" 98'-0 1/2" 1/3 DE 53'-5" 98'-0 1/2" G130 2 REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED A524 2 A524 3 A524 1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 2 : 4 8 P M G123 1648.001 AD/AO Checker CODE COMPLIANCE THIRD FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 3RD FLOOR -OCCUPANCY PLAN KEYNOTE LEGEND Key Value Keynote Text ACCESSORY OCCUPANCY CALCULATIONS PER FLOOR LevelArea Total Floor Area % per Floor BUILDING A GROUND FLOOR1,583 SF18,785 SF 8% BUILDING B 2ND FLOOR T.O.C.201 SF8,158 SF 2% T.O.S.F. 3RD FLOOR296 SF8,111 SF 4% T.O.S.F. 4TH FLOOR92 SF8,111 SF 1% T.O.S.F. 5TH FLOOR296 SF8,111 SF 4% T.O.S.F. 6TH FLOOR296 SF8,111 SF 4% BUILDING C 2ND FLOOR T.O.C.327 SF6,068 SF 5% T.O.S.F. 3RD FLOOR327 SF5,975 SF 5% T.O.S.F. 4TH FLOOR327 SF5,975 SF 5% T.O.S.F. 5TH FLOOR327 SF5,975 SF 5% T.O.S.F. 6TH FLOOR327 SF5,975 SF 5% INCIDENTIAL USE CALCUATIONS PER FLOOR MVArea Total Floor Area % per Floor BUILDING A GROUND FLOOR385 SF18,785 SF 2% BUILDING B 2ND FLOOR T.O.C.400 SF8,158 SF 5% T.O.S.F. 3RD FLOOR195 SF8,111 SF 2% T.O.S.F. 4TH FLOOR400 SF8,111 SF 5% T.O.S.F. 5TH FLOOR195 SF8,111 SF 2% T.O.S.F. 6TH FLOOR195 SF8,111 SF 2% REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1. EXIT STAIRWAYS ACCESSED FROM A HORIZONTAL EXIT DO NOT NEED AN AREA OF REFUGE PER CBC SECTION 1009.3 AND PER EXCEPTION 2, DO NOT REQUIRE A CLEAR WIDTH OF 48 INCHES BETWEEN HANDRAILS IN BUILDING EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CBC SECTION 903.3.1.1. OR 903.3.1.2. 2. ELEVATOR IN BUILDING TO COMPLY WITH SECTION 1009.4 AS A PART OF THE ACCESSIBLE MEANS OF EGRESS. 3. ACCESSIBLE PATH OF EGRESS SHALL BE 44" MIN. CLEAR WIDTH THROUGHOUT BUILDING. (36" MIN. IN UNITS AND OTHER AREAS < 10 OCCUPANTS) CBC TABLE 1020.2. 4. STAIRWAYS SHALL BE MIN. 44" WIDE (36" MIN. SERVING AN OCCUPANT LOAD OF LESS THAN 50) PER SEC. 1011.2 AND (CBC 1011.7.1). 5. CARPET IN EXIT ENCLOSURES IS NOT ALLOWED. 6. EXIT DOOR SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND ONLY REQUIRE SINGLE ACTION (1010.1.9 CFC & CBC). EXIT ANALYSIS NOTES I.U. R-2 A.0. OCCUPANCY OCCUPANCY OCCUPANCY ACCESSORY OCCUPANCY TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED WITH NO SEPARATION REQUIRED BETWEEN THE ACCESSORY OCCUPANCY AND THE MAIN OCCUPANCY (CBC 508.2) INCIDENTAL USES TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED (CBC 509.3). REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 509). RESIDENTIAL OCCUPANCY, PER CBC 310.4 REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). M OCCUPANCY MERCANTILE OCCUPANCY PER CBC 309.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). S-2 OCCUPANCY LOW HAZARD STORAGE OCCUPANCY PER CBC 311.3. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). B OCCUPANCY BUSINESS GROUP OCCUPANCY PER CBC 304.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). OCCUPANCY LEGEND EXIT SIGNAGE COMPLYING WITH CBC 1013 & 1143A, SHALL BE PROVIDED WITH THE FOLLOWING TEXTS, SEE PLAN FOR LOCATIONS: A. EXIT B. EXIT STAIR DOWN C. NOT AN EXIT D. EXIT ROUTE E. TO EXIT F. STAIRWAY IDENTIFICATION SIGN, SEE DETAIL 1/-G. FLOOR LEVEL ID SIGN WITHIN STAIRWELL, SEE DETAIL 1/-TEXT BRAILLE 1" HT. + 60" MAX TO FLOOR BRAILLE EXIT SIGN KEYNOTES EXIT SIGN, S.E.D. KB FE OL ### KNOX BOX UNIT SHALL BE LOCATED ON THE EXTERIOR, RIGHT SIDE OF THE DOOR, BETWEEN FIVE AND SIX FEET ABOVE GROUND. PROVIDE MASTER KEYS AND ACCESS CONTROL CARDS TO OBTAIN ACCESS TO ALL AREAS WITHIN THE BUILDING. IN ADDITION, PROVIDE KEYS NECESSARY TO OPERATE FIRE ALARM CONTROL PANELS, ANNUNCIATORS, RESET OF ALARM DEVICES LOCKS FOR SPRINKLER CONTROL VALVES, PIV, BACK FLOW, ETC. CONTACT THE FIRE DISTRICT FOR APPLICATION AND PURCHASE. ALLOWABLE SF PER OCCUPANT (PER CBC TABLE 1004.1.2) NUMBER OF EXITS REQUIRED (PER CBC 1006.2.1) PANIC INTERIOR ACCESSIBLE PATH OF EGRESS. 10 OR MORE OCCUPANTS 44" MIN. WIDTH; LESS THAN 10 OCCUPANTS 36" MIN. WIDTH (CBC 1119A.3). ACTUAL DISTANCE BETWEEN EXITS PROVIDED. ED EXIT DISCHARGE TO PUBLIC WAY PER CBC 1028 OCCUPANCY TYPE SEMI RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER (2A:10B:C) SEE EXTINGUISHERS SHALL BE MOUNTED ON THE WALL OR IN CABINETS, SUCH THAT THE TOP OF THE EXTINGUISHER IS NO MORE THAN FOUR(4) FEET ABOVE FLOOR LEVEL. EXTINGUISHER SHALL BE COMMERCIAL GRADE, CURRENTLY TAGGED, OR HAVE MANUFACTURER DATE CLEARLY MARKED ON THE EXTINGUISHER. OCCUPANCY EXITING LOAD (ARROW INDICATES DIRECTION OF TRAVEL). EX X FR FA PROPERTY LINE 100 R-2 100-01 A FIRE SPRINKLER STANDPIPE VEHICLE STALL ENTRY LINE VEHICLE STALL EXIT LINE ELEVATOR SMOKE GUARD SIGN: "THIS ROOM'S MAXIMUM OCCUPANCY IS _________ PERSONS" PER CBC 1004.3, MOUNT AT 7'-0" (U.O.N) VERIFY LOCATION WITH ARCHITECT. -NUMBER OF OCCUPANTS EXTERIOR BUILDING SIGNAGE, SEE ELEVATIONS FOR FURTHER INFORMATION DOOR TO BE EQUIPPED WITH PANIC HARDWARE -SEE PROJECT MANUAL AND HARDWARE SCHEDULE FOR MORE INFORMATION. ROOM NAME AND NUMBER SIGNAGE FIRE RATED WINDOW, PER CBC (716.2), SEE WINDOW SCHEDULE SHEETS A7.2 SERIES EMERGENCY EXITING DIAGRAM IN CLEAR PLASTIC HOLDER (8 1/2" x 11" FORMAT). FIRE RISER ROOM SIGNAGE PER CFC 509.1 FIRE ALARM CONTROL PANEL SIGNAGE PER CFC 509.1 DOOR TAG, SEE DOOR SCHEDULE, SHEETS A7.1 SERIES PROPOSED LOCATION OF ANNUNCIATOR PANEL ANNUNCIATOR PANEL IS PART A DEFERRED SUBMITTAL. FINAL PANEL LOCATION SHALL BE DETERMINED AT THE TIME OF SUBMITTAL BY CITY FIRE DEPARTMENT. B ROOM NAME OCCUPANCY TYPE (PER CBC CH. 3) SQUARE FOOTAGE OCCUPANT LOAD DOOR EXITING WIDTH 36" CLR. MAX EXIT CAPACITY 180 CLEAR WIDTH AT DOOR MAXIMUM CAPACITY OF THE EXIT = CLEAR WIDTH 0.2 FACTOR CODE ANALYSIS LEGEND 100 ROOM 1,000 SF 1 EXIT(S) 10 10 ROOM NUMBER RM MD. 1/3 40' - 0" 120'-0" AP 1/3 DE 40'-0" 0" MAXIMUM DIAGONAL DIMENSION OF BUILDING AREA PER CBC SECTION 1007.1.1 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 92 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 195 SF 300 SF/OCC. EXIT(S) I.U. 1,083 SF 200 SF/OCC. EXIT(S) R590 SF 3 200 SF/OCC. 1 EXIT(S) R1,080 SF 200 SF/OCC. EXIT(S) -2 1,057 SF 200 SF/OCC. EXIT(S) R-2 809 SF 5 200 SF/OCC. 1 EXIT(S) R1,304 SF 200 SF/OCC. EXIT(S) R1,084 SF 6 200 SF/OCC. 1 EXIT(S) R846 SF 200 SF/OCC. EXIT(S) R-2 291 SF 1 300 SF/OCC. EXIT(S) A.0. 784 SF 4 200 SF/OCC. 1 EXIT(S) R538 SF 3 200 SF/OCC. 1 EXIT(S) R1,080 SF 200 SF/OCC. EXIT(S) R-2 204 SF 1 300 SF/OCC. EXIT(S) I.U. 846 SF 200 SF/OCC. EXIT(S) RJANITOR TRASH UNIT 3A UNIT 2B FLEX ROOM ELEVATOR 1 UNIT 1B UNIT 3A UNIT 3A UNIT 3A UNIT 1A UNIT 2A UNIT 2A STAIR 2 UNIT 4A FLEX ROOM UNIT 2B UNIT 3A STAIR 1 5 3 6 5 7 6 ELEVATOR 2 34 34 IDF 35 SF 300 SF/OCC. EXIT(S) A.0. 1 REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 2 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" REQ'D DOOR WIDTH (.2) = 3 TOTAL OCCUPANT LOAD = 15 DOOR WIDTH PROVIDED = 3'-0" REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 1 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" REQ'D DOOR WIDTH (.2) = 3.8 TOTAL OCCUPANT LOAD = 19 DOOR WIDTH PROVIDED = 3'-0" G130 1 DEAD E ND CORRIDOR LENGTH 43'-10" DEAD E ND CORRIDOR LENGTH 49'-10" WEST CORRIDOR EAST CORRIDOR 48'-8" 1/3 DE 40'-1" 48'-8" 98'-0 1/2" 1/3 DE 53'-5" 98'-0 1/2" 120-21/2 " 160-3" MD 1/3 401 " 120-3 MD 1/3 53 -5 160-3 G130 2 REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED A524 2 A524 3 A524 1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 3 : 0 0 P M G124 1648.001 AD/AO Checker CODE COMPLIANCE FOURTH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 4TH FLOOR -OCCUPANCY PLAN KEYNOTE LEGEND Key Value Keynote Text ACCESSORY OCCUPANCY CALCULATIONS PER FLOOR LevelArea Total Floor Area % per Floor BUILDING A GROUND FLOOR1,583 SF18,785 SF 8% BUILDING B 2ND FLOOR T.O.C.201 SF8,158 SF 2% T.O.S.F. 3RD FLOOR296 SF8,111 SF 4% T.O.S.F. 4TH FLOOR92 SF8,111 SF 1% T.O.S.F. 5TH FLOOR296 SF8,111 SF 4% T.O.S.F. 6TH FLOOR296 SF8,111 SF 4% BUILDING C 2ND FLOOR T.O.C.327 SF6,068 SF 5% T.O.S.F. 3RD FLOOR327 SF5,975 SF 5% T.O.S.F. 4TH FLOOR327 SF5,975 SF 5% T.O.S.F. 5TH FLOOR327 SF5,975 SF 5% T.O.S.F. 6TH FLOOR327 SF5,975 SF 5% INCIDENTIAL USE CALCUATIONS PER FLOOR MVArea Total Floor Area % per Floor BUILDING A GROUND FLOOR385 SF18,785 SF 2% BUILDING B 2ND FLOOR T.O.C.400 SF8,158 SF 5% T.O.S.F. 3RD FLOOR195 SF8,111 SF 2% T.O.S.F. 4TH FLOOR400 SF8,111 SF 5% T.O.S.F. 5TH FLOOR195 SF8,111 SF 2% T.O.S.F. 6TH FLOOR195 SF8,111 SF 2% REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1. EXIT STAIRWAYS ACCESSED FROM A HORIZONTAL EXIT DO NOT NEED AN AREA OF REFUGE PER CBC SECTION 1009.3 AND PER EXCEPTION 2, DO NOT REQUIRE A CLEAR WIDTH OF 48 INCHES BETWEEN HANDRAILS IN BUILDING EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CBC SECTION 903.3.1.1. OR 903.3.1.2. 2. ELEVATOR IN BUILDING TO COMPLY WITH SECTION 1009.4 AS A PART OF THE ACCESSIBLE MEANS OF EGRESS. 3. ACCESSIBLE PATH OF EGRESS SHALL BE 44" MIN. CLEAR WIDTH THROUGHOUT BUILDING. (36" MIN. IN UNITS AND OTHER AREAS < 10 OCCUPANTS) CBC TABLE 1020.2. 4. STAIRWAYS SHALL BE MIN. 44" WIDE (36" MIN. SERVING AN OCCUPANT LOAD OF LESS THAN 50) PER SEC. 1011.2 AND (CBC 1011.7.1). 5. CARPET IN EXIT ENCLOSURES IS NOT ALLOWED. 6. EXIT DOOR SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND ONLY REQUIRE SINGLE ACTION (1010.1.9 CFC & CBC). EXIT ANALYSIS NOTES I.U. R-2 A.0. OCCUPANCY OCCUPANCY OCCUPANCY ACCESSORY OCCUPANCY TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED WITH NO SEPARATION REQUIRED BETWEEN THE ACCESSORY OCCUPANCY AND THE MAIN OCCUPANCY (CBC 508.2) INCIDENTAL USES TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED (CBC 509.3). REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 509). RESIDENTIAL OCCUPANCY, PER CBC 310.4 REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). M OCCUPANCY MERCANTILE OCCUPANCY PER CBC 309.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). S-2 OCCUPANCY LOW HAZARD STORAGE OCCUPANCY PER CBC 311.3. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). B OCCUPANCY BUSINESS GROUP OCCUPANCY PER CBC 304.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). OCCUPANCY LEGEND EXIT SIGNAGE COMPLYING WITH CBC 1013 & 1143A, SHALL BE PROVIDED WITH THE FOLLOWING TEXTS, SEE PLAN FOR LOCATIONS: A. EXIT B. EXIT STAIR DOWN C. NOT AN EXIT D. EXIT ROUTE E. TO EXIT F. STAIRWAY IDENTIFICATION SIGN, SEE DETAIL 1/-G. FLOOR LEVEL ID SIGN WITHIN STAIRWELL, SEE DETAIL 1/-TEXT BRAILLE 1" HT. + 60" MAX TO FLOOR BRAILLE EXIT SIGN KEYNOTES EXIT SIGN, S.E.D. KB FE OL ### KNOX BOX UNIT SHALL BE LOCATED ON THE EXTERIOR, RIGHT SIDE OF THE DOOR, BETWEEN FIVE AND SIX FEET ABOVE GROUND. PROVIDE MASTER KEYS AND ACCESS CONTROL CARDS TO OBTAIN ACCESS TO ALL AREAS WITHIN THE BUILDING. IN ADDITION, PROVIDE KEYS NECESSARY TO OPERATE FIRE ALARM CONTROL PANELS, ANNUNCIATORS, RESET OF ALARM DEVICES LOCKS FOR SPRINKLER CONTROL VALVES, PIV, BACK FLOW, ETC. CONTACT THE FIRE DISTRICT FOR APPLICATION AND PURCHASE. ALLOWABLE SF PER OCCUPANT (PER CBC TABLE 1004.1.2) NUMBER OF EXITS REQUIRED (PER CBC 1006.2.1) PANIC INTERIOR ACCESSIBLE PATH OF EGRESS. 10 OR MORE OCCUPANTS 44" MIN. WIDTH; LESS THAN 10 OCCUPANTS 36" MIN. WIDTH (CBC 1119A.3). ACTUAL DISTANCE BETWEEN EXITS PROVIDED. ED EXIT DISCHARGE TO PUBLIC WAY PER CBC 1028 OCCUPANCY TYPE SEMI RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER (2A:10B:C) SEE EXTINGUISHERS SHALL BE MOUNTED ON THE WALL OR IN CABINETS, SUCH THAT THE TOP OF THE EXTINGUISHER IS NO MORE THAN FOUR(4) FEET ABOVE FLOOR LEVEL. EXTINGUISHER SHALL BE COMMERCIAL GRADE, CURRENTLY TAGGED, OR HAVE MANUFACTURER DATE CLEARLY MARKED ON THE EXTINGUISHER. OCCUPANCY EXITING LOAD (ARROW INDICATES DIRECTION OF TRAVEL). EX X FR FA PROPERTY LINE 100 R-2 100-01 A FIRE SPRINKLER STANDPIPE VEHICLE STALL ENTRY LINE VEHICLE STALL EXIT LINE ELEVATOR SMOKE GUARD SIGN: "THIS ROOM'S MAXIMUM OCCUPANCY IS _________ PERSONS" PER CBC 1004.3, MOUNT AT 7'-0" (U.O.N) VERIFY LOCATION WITH ARCHITECT. -NUMBER OF OCCUPANTS EXTERIOR BUILDING SIGNAGE, SEE ELEVATIONS FOR FURTHER INFORMATION DOOR TO BE EQUIPPED WITH PANIC HARDWARE -SEE PROJECT MANUAL AND HARDWARE SCHEDULE FOR MORE INFORMATION. ROOM NAME AND NUMBER SIGNAGE FIRE RATED WINDOW, PER CBC (716.2), SEE WINDOW SCHEDULE SHEETS A7.2 SERIES EMERGENCY EXITING DIAGRAM IN CLEAR PLASTIC HOLDER (8 1/2" x 11" FORMAT). FIRE RISER ROOM SIGNAGE PER CFC 509.1 FIRE ALARM CONTROL PANEL SIGNAGE PER CFC 509.1 DOOR TAG, SEE DOOR SCHEDULE, SHEETS A7.1 SERIES PROPOSED LOCATION OF ANNUNCIATOR PANEL ANNUNCIATOR PANEL IS PART A DEFERRED SUBMITTAL. FINAL PANEL LOCATION SHALL BE DETERMINED AT THE TIME OF SUBMITTAL BY CITY FIRE DEPARTMENT. B ROOM NAME OCCUPANCY TYPE (PER CBC CH. 3) SQUARE FOOTAGE OCCUPANT LOAD DOOR EXITING WIDTH 36" CLR. MAX EXIT CAPACITY 180 CLEAR WIDTH AT DOOR MAXIMUM CAPACITY OF THE EXIT = CLEAR WIDTH 0.2 FACTOR CODE ANALYSIS LEGEND 100 ROOM 1,000 SF 1 EXIT(S) 10 10 ROOM NUMBER RM MD. 1/3 40' - 0" 120'-0" AP 1/3 DE 40'-0" 0" MAXIMUM DIAGONAL DIMENSION OF BUILDING AREA PER CBC SECTION 1007.1.1 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 545 SF 200 SF/OCC. EXIT(S) R-2 802 SF 200 SF/OCC. 1 EXIT(S) R-2 291 SF 300 SF/OCC. EXIT(S) A.0. 846 SF 200 SF/OCC. EXIT(S) R-2 1,084 SF 200 SF/OCC. EXIT(S) -2 1,304 SF 7 200 SF/OCC. 1 EXIT(S) R808 SF 200 SF/OCC. EXIT(S) -2 1,057 SF 6 200 SF/OCC. 1 EXIT(S) R1,081 SF 200 SF/OCC. EXIT(S) R590 SF 200 SF/OCC. EXIT(S) -2 1,082 SF 200 SF/OCC. EXIT(S) R-2 195 SF 300 SF/OCC. EXIT(S) I.U. 92 SF 300 SF/OCC. EXIT(S) A.0. 846 SF 200 SF/OCC. EXIT(S) R-2 205 SF 300 SF/OCC. EXIT(S) A.0. 1,085 SF 200 SF/OCC. EXIT(S) RUNIT 3A UNIT 1A UNIT 2A UNIT 2B UNIT 3A UNIT 4A UNIT 2A UNIT 3A UNIT 3A UNIT 1B UNIT 3A TRASH JANITOR UNIT 2B LAUNDRY ROOM ELEVATOR 1 FLEX ROOM 1 3 5 5 6 STAIR 1 ELEVATOR 2 STAIR 2 DEAD E ND CORRIDOR LENGTH 43'-10" REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 2 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" 34 34 REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 1 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" IDF 35 SF 1 300 SF/OCC. 1 EXIT(S) A.0. REQ'D DOOR WIDTH (.2) = 3 TOTAL OCCUPANT LOAD = 15 DOOR WIDTH PROVIDED = 3'-0" REQ'D DOOR WIDTH (.2) = 3.8 TOTAL OCCUPANT LOAD = 19 DOOR WIDTH PROVIDED = 3'-0" G130 1 DEAD END CORRIDOR LENGTH 49'-10" WEST CORRIDOR EAST CORRIDOR 48'-8" 1/3 DE 40'-1" 48'-8" 98'-0 1/2" 1/3 DE 53'-5" 98'-0 1/2" 120-21/2 " MD 1/3 401 120'-3 " 160-3" MD 1/3 53 -5 160-3 G130 2 REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED A524 2 A524 3 A524 1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 3 : 1 2 P M G125 1648.001 AD/AO Checker CODE COMPLIANCE FIFTH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 5TH FLOOR -OCCUPANCY PLAN KEYNOTE LEGEND Key Value Keynote Text ACCESSORY OCCUPANCY CALCULATIONS PER FLOOR LevelArea Total Floor Area % per Floor BUILDING A GROUND FLOOR1,583 SF18,785 SF 8% BUILDING B 2ND FLOOR T.O.C.201 SF8,158 SF 2% T.O.S.F. 3RD FLOOR296 SF8,111 SF 4% T.O.S.F. 4TH FLOOR92 SF8,111 SF 1% T.O.S.F. 5TH FLOOR296 SF8,111 SF 4% T.O.S.F. 6TH FLOOR296 SF8,111 SF 4% BUILDING C 2ND FLOOR T.O.C.327 SF6,068 SF 5% T.O.S.F. 3RD FLOOR327 SF5,975 SF 5% T.O.S.F. 4TH FLOOR327 SF5,975 SF 5% T.O.S.F. 5TH FLOOR327 SF5,975 SF 5% T.O.S.F. 6TH FLOOR327 SF5,975 SF 5% INCIDENTIAL USE CALCUATIONS PER FLOOR MVArea Total Floor Area % per Floor BUILDING A GROUND FLOOR385 SF18,785 SF 2% BUILDING B 2ND FLOOR T.O.C.400 SF8,158 SF 5% T.O.S.F. 3RD FLOOR195 SF8,111 SF 2% T.O.S.F. 4TH FLOOR400 SF8,111 SF 5% T.O.S.F. 5TH FLOOR195 SF8,111 SF 2% T.O.S.F. 6TH FLOOR195 SF8,111 SF 2% REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF.REF. REF. DN UP DN 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1. EXIT STAIRWAYS ACCESSED FROM A HORIZONTAL EXIT DO NOT NEED AN AREA OF REFUGE PER CBC SECTION 1009.3 AND PER EXCEPTION 2, DO NOT REQUIRE A CLEAR WIDTH OF 48 INCHES BETWEEN HANDRAILS IN BUILDING EQUIPPED WITH AN AUTOMATIC SPRINKLER SYSTEM INSTALLED IN ACCORDANCE WITH CBC SECTION 903.3.1.1. OR 903.3.1.2. 2. ELEVATOR IN BUILDING TO COMPLY WITH SECTION 1009.4 AS A PART OF THE ACCESSIBLE MEANS OF EGRESS. 3. ACCESSIBLE PATH OF EGRESS SHALL BE 44" MIN. CLEAR WIDTH THROUGHOUT BUILDING. (36" MIN. IN UNITS AND OTHER AREAS < 10 OCCUPANTS) CBC TABLE 1020.2. 4. STAIRWAYS SHALL BE MIN. 44" WIDE (36" MIN. SERVING AN OCCUPANT LOAD OF LESS THAN 50) PER SEC. 1011.2 AND (CBC 1011.7.1). 5. CARPET IN EXIT ENCLOSURES IS NOT ALLOWED. 6. EXIT DOOR SHALL BE OPERABLE FROM INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT AND ONLY REQUIRE SINGLE ACTION (1010.1.9 CFC & CBC). EXIT ANALYSIS NOTES I.U. R-2 A.0. OCCUPANCY OCCUPANCY OCCUPANCY ACCESSORY OCCUPANCY TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED WITH NO SEPARATION REQUIRED BETWEEN THE ACCESSORY OCCUPANCY AND THE MAIN OCCUPANCY (CBC 508.2) INCIDENTAL USES TO BE A MAXIMUM 10% OF THE BUILDING AREA OF THE STORY IN WHICH THEY ARE LOCATED (CBC 509.3). REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 509). RESIDENTIAL OCCUPANCY, PER CBC 310.4 REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). M OCCUPANCY MERCANTILE OCCUPANCY PER CBC 309.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). S-2 OCCUPANCY LOW HAZARD STORAGE OCCUPANCY PER CBC 311.3. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). B OCCUPANCY BUSINESS GROUP OCCUPANCY PER CBC 304.1. REQUIRES SEPARATION FROM OTHER OCCUPANCIES (CBC TABLE 508.4). OCCUPANCY LEGEND EXIT SIGNAGE COMPLYING WITH CBC 1013 & 1143A, SHALL BE PROVIDED WITH THE FOLLOWING TEXTS, SEE PLAN FOR LOCATIONS: A. EXIT B. EXIT STAIR DOWN C. NOT AN EXIT D. EXIT ROUTE E. TO EXIT F. STAIRWAY IDENTIFICATION SIGN, SEE DETAIL 1/-G. FLOOR LEVEL ID SIGN WITHIN STAIRWELL, SEE DETAIL 1/-TEXT BRAILLE 1" HT. + 60" MAX TO FLOOR BRAILLE EXIT SIGN KEYNOTES EXIT SIGN, S.E.D. KB FE OL ### KNOX BOX UNIT SHALL BE LOCATED ON THE EXTERIOR, RIGHT SIDE OF THE DOOR, BETWEEN FIVE AND SIX FEET ABOVE GROUND. PROVIDE MASTER KEYS AND ACCESS CONTROL CARDS TO OBTAIN ACCESS TO ALL AREAS WITHIN THE BUILDING. IN ADDITION, PROVIDE KEYS NECESSARY TO OPERATE FIRE ALARM CONTROL PANELS, ANNUNCIATORS, RESET OF ALARM DEVICES LOCKS FOR SPRINKLER CONTROL VALVES, PIV, BACK FLOW, ETC. CONTACT THE FIRE DISTRICT FOR APPLICATION AND PURCHASE. ALLOWABLE SF PER OCCUPANT (PER CBC TABLE 1004.1.2) NUMBER OF EXITS REQUIRED (PER CBC 1006.2.1) PANIC INTERIOR ACCESSIBLE PATH OF EGRESS. 10 OR MORE OCCUPANTS 44" MIN. WIDTH; LESS THAN 10 OCCUPANTS 36" MIN. WIDTH (CBC 1119A.3). ACTUAL DISTANCE BETWEEN EXITS PROVIDED. ED EXIT DISCHARGE TO PUBLIC WAY PER CBC 1028 OCCUPANCY TYPE SEMI RECESSED FIRE EXTINGUISHER CABINET AND EXTINGUISHER (2A:10B:C) SEE EXTINGUISHERS SHALL BE MOUNTED ON THE WALL OR IN CABINETS, SUCH THAT THE TOP OF THE EXTINGUISHER IS NO MORE THAN FOUR(4) FEET ABOVE FLOOR LEVEL. EXTINGUISHER SHALL BE COMMERCIAL GRADE, CURRENTLY TAGGED, OR HAVE MANUFACTURER DATE CLEARLY MARKED ON THE EXTINGUISHER. OCCUPANCY EXITING LOAD (ARROW INDICATES DIRECTION OF TRAVEL). EX X FR FA PROPERTY LINE 100 R-2 100-01 A FIRE SPRINKLER STANDPIPE VEHICLE STALL ENTRY LINE VEHICLE STALL EXIT LINE ELEVATOR SMOKE GUARD SIGN: "THIS ROOM'S MAXIMUM OCCUPANCY IS _________ PERSONS" PER CBC 1004.3, MOUNT AT 7'-0" (U.O.N) VERIFY LOCATION WITH ARCHITECT. -NUMBER OF OCCUPANTS EXTERIOR BUILDING SIGNAGE, SEE ELEVATIONS FOR FURTHER INFORMATION DOOR TO BE EQUIPPED WITH PANIC HARDWARE -SEE PROJECT MANUAL AND HARDWARE SCHEDULE FOR MORE INFORMATION. ROOM NAME AND NUMBER SIGNAGE FIRE RATED WINDOW, PER CBC (716.2), SEE WINDOW SCHEDULE SHEETS A7.2 SERIES EMERGENCY EXITING DIAGRAM IN CLEAR PLASTIC HOLDER (8 1/2" x 11" FORMAT). FIRE RISER ROOM SIGNAGE PER CFC 509.1 FIRE ALARM CONTROL PANEL SIGNAGE PER CFC 509.1 DOOR TAG, SEE DOOR SCHEDULE, SHEETS A7.1 SERIES PROPOSED LOCATION OF ANNUNCIATOR PANEL ANNUNCIATOR PANEL IS PART A DEFERRED SUBMITTAL. FINAL PANEL LOCATION SHALL BE DETERMINED AT THE TIME OF SUBMITTAL BY CITY FIRE DEPARTMENT. B ROOM NAME OCCUPANCY TYPE (PER CBC CH. 3) SQUARE FOOTAGE OCCUPANT LOAD DOOR EXITING WIDTH 36" CLR. MAX EXIT CAPACITY 180 CLEAR WIDTH AT DOOR MAXIMUM CAPACITY OF THE EXIT = CLEAR WIDTH 0.2 FACTOR CODE ANALYSIS LEGEND 100 ROOM 1,000 SF 1 EXIT(S) 10 10 ROOM NUMBER RM MD. 1/3 40' - 0" 120'-0" AP 1/3 DE 40'-0" 0" MAXIMUM DIAGONAL DIMENSION OF BUILDING AREA PER CBC SECTION 1007.1.1 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1/3 OF THE MAXIMUM DIAGONAL DIMENSION PER CBC SEC. 1007.1.1.2 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 802 SF 200 SF/OCC. EXIT(S) -2 JANITOR TRASH UNIT 3A UNIT 2B FLEX ROOM ELEVATOR 1 STAIR 1 UNIT 1B ELEVATOR 2 UNIT 3A UNIT 3A UNIT 2A STAIR 2 UNIT 4A UNIT 3A UNIT 2B FLEX ROOM UNIT 2A UNIT 1A UNIT 3A 291 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 846 SF 5 200 SF/OCC. 1 EXIT(S) R1,084 SF 6 200 SF/OCC. 1 EXIT(S) R1,304 SF 7 200 SF/OCC. 1 EXIT(S) R808 SF 5 200 SF/OCC. 1 EXIT(S) R-2 1,057 SF 200 SF/OCC. EXIT(S) R1,080 SF 200 SF/OCC. EXIT(S) R590 SF 3 200 SF/OCC. 1 EXIT(S) R1,083 SF 6 200 SF/OCC. 1 EXIT(S) R846 SF 200 SF/OCC. EXIT(S) R195 SF 300 SF/OCC. EXIT(S) I.U. 92 SF 1 300 SF/OCC. 1 EXIT(S) A.0. 205 SF 300 SF/OCC. EXIT(S) A.0. 545 SF 200 SF/OCC. EXIT(S) R1,085 SF 6 200 SF/OCC. 1 EXIT(S) R1 3 1 6 7 6 DEAD E ND CORRIDOR LENGTH 43'-10" WEST CORRIDOR EAST CORRIDOR REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 2 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" 34 REQ'D DOOR WIDTH (.2) = TOTAL OCCUPANT LOAD = 15 DOOR WIDTH PROVIDED = 3'-0" 34 REQ'D DOOR WIDTH (.2) = 6.8 REQ'D STAIR WIDTH (.3) = 10.2 STAIR 1 TOTAL OCCUPANT LOAD = 34 DOOR WIDTH PROVIDED = 3'-0" STAIR WIDTH PROVIDED = 4'-0" IDF 35 SF 300 SF/OCC. EXIT(S) A.0. REQ'D DOOR WIDTH (.2) = 3.8 TOTAL OCCUPANT LOAD = 19 DOOR WIDTH PROVIDED = 3'-0" G130 1 DEAD END CORRIDOR LENGTH 49'-10" 120-21/2 " MD 1/3 401 " 120-3 160-3 48'-8" MD 1/3 53 -5 160-3 1/3 DE 40'-1" 48'-8" 98'-0 1/2" 1/3 DE 53'-5" 98'-0 1/2" G130 2 REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED REQUIRED REFUGE AREA PER CBC 1026.4 38 OCCUPANTS + 30 OCCUPANTS = 68 OCCUPANTS 36" (DOOR WIDTH) .2" (REQ'D DOOR WITH FACTOR) = 180 OCCUPANTS 68 OCCUPANTS x 3 SQFT = 204 SQFT REQUIRED A524 2 A524 3 A524 1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 3 : 2 4 P M G126 1648.001 AD/AO Checker CODE COMPLIANCE SIXTH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 6TH FLOOR -OCCUPANCY PLAN KEYNOTE LEGEND Key Value Keynote Text ACCESSORY OCCUPANCY CALCULATIONS PER FLOOR LevelArea Total Floor Area % per Floor BUILDING A GROUND FLOOR1,583 SF18,785 SF 8% BUILDING B 2ND FLOOR T.O.C.201 SF8,158 SF 2% T.O.S.F. 3RD FLOOR296 SF8,111 SF 4% T.O.S.F. 4TH FLOOR92 SF8,111 SF 1% T.O.S.F. 5TH FLOOR296 SF8,111 SF 4% T.O.S.F. 6TH FLOOR296 SF8,111 SF 4% BUILDING C 2ND FLOOR T.O.C.327 SF6,068 SF 5% T.O.S.F. 3RD FLOOR327 SF5,975 SF 5% T.O.S.F. 4TH FLOOR327 SF5,975 SF 5% T.O.S.F. 5TH FLOOR327 SF5,975 SF 5% T.O.S.F. 6TH FLOOR327 SF5,975 SF 5% INCIDENTIAL USE CALCUATIONS PER FLOOR MVArea Total Floor Area % per Floor BUILDING A GROUND FLOOR385 SF18,785 SF 2% BUILDING B 2ND FLOOR T.O.C.400 SF8,158 SF 5% T.O.S.F. 3RD FLOOR195 SF8,111 SF 2% T.O.S.F. 4TH FLOOR400 SF8,111 SF 5% T.O.S.F. 5TH FLOOR195 SF8,111 SF 2% T.O.S.F. 6TH FLOOR195 SF8,111 SF 2% REVISIONS
UP UP REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ELECTRICAL GARAGE STAIR 1 CORRIDOR ELEVATOR 2 ELEV. EQUIPM. R.R. OFFICE OFFICE BIKE ROOM FLEX SPACE STAIR 2 MECHANICAL MPOE ERRCS FIRE PUMP DUMPSTER ROOM ELEV. EQUIPM. ELEVATOR 1 EXIT ACCESS TRAVEL PATH 1 EXIT ACCESS TRAVEL PATH 3 EXIT ACCESS TRAVEL PATH COMMON PATH OF TRAVEL PATH COMMON PATH OF TRAVEL PATH 2 JANITOR TRASH UNIT 2B BIKE ROOM ELEVATOR 1 STORAGE COMMUNITY ROOM UNIT 1A UNIT 2A R.R. IDF MAINTENANCE UNIT 2B UNIT 3A UNIT 4A STAIR 2 UNIT 2A UNIT 3A UNIT 3A UNIT 1B UNIT 3A STAIR 1 ELEVATOR 2 WEST CORRIDOR EAST CORRIDOR DEAD E ND CORRIDOR LENGTH 43'-10" R.R. DEAD E ND CORRIDOR LENGTH 49'-10" COMMON PATH OF TRAVEL PATH COMMON PATH OF TRAVEL PATH COMMON PATH OF TRAVEL PATH COMMON PATH OF TRAVEL PATH COMMON PATH OF TRAVEL PATH 5 EXIT ACCESS TRAVEL PATH 4 EXIT ACCESS TRAVEL PATH 3 EXIT ACCESS TRAVEL PATH EXIT ACCESS TRAVEL PATH 1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 3 : 4 3 P M G127 1648.001 AD/AO Checker CODE COMPLIANCE PATH OF TRAVEL THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 GROUND FLOOR -OCCUPANCY PLAN 1/8" = 1'-0" 2 2ND FLOOR -EGRESS PLAN COMMON PATH OF TRAVEL DISTANCE MAXIMUM = 125' (2ND FLOOR) MarkFrom RoomTo Room Length 1JANITOR 201WESTCORRIDOR 226 75'-0" UNIT 3A 215WESTCORRIDOR 226 43'-5" 3UNIT 2A 214EAST CORRIDOR 225 31'-3" 4UNIT 2A 217EAST CORRIDOR 225 32'-1" 5UNIT 3A 223EAST CORRIDOR 225 84'-3" EXIT ACCESS TRAVEL DISTANCE MAXIMUM - 250' (2ND FLOOR) MarkFrom RoomTo Room Length 1 JANITOR 201WESTCORRIDOR 226 75'-10" 2 UNIT 3A 215WESTCORRIDOR 226 134'-2" 3 UNIT 2A 217EAST CORRIDOR 225 55'-8" 4 UNIT 3A 223EAST CORRIDOR 225 87'-11" COMMON PATH OF TRAVEL DISTANCE MAXIMUM = 75' (GROUND FLOOR) MarkFrom RoomTo Room Length EXIT ACCESS TRAVEL DISTANCE MAXIMUM - 250' (GROUND FLOOR) Mark From RoomTo Room Length REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND JANITOR TRASH UNIT 2B UNIT 3A LAUNDRY ELEVATOR 1 WEST CORRIDOR UNIT 1B ELEVATOR 2 UNIT 3A UNIT 3A UNIT 3A UNIT 1A UNIT 2A UNIT 2A TEEN ROOM STAIR 2 UNIT 4A UNIT 2B UNIT 3A EAST CORRIDOR DEAD E ND CORRIDOR LENGTH 49'-10" DEAD E ND CORRIDOR LENGTH 43'-10" STAIR 1 IDF COMMON PATH OF TRAVEL PATH 4 COMMON PATH OF TRAVEL PATH 3 COMMON PATH OF TRAVEL PATH 2 COMMON PATH OF TRAVEL PATH 1 COMMON PATH OF TRAVEL PATH 5 EXIT ACCESS TRAVEL PATH 4 EXIT ACCESS TRAVEL PATH 3 EXIT ACCESS TRAVEL PATH 2 EXIT ACCESS TRAVEL PATH 1 JANITOR TRASH UNIT 3A UNIT 2B FLEX ROOM ELEVATOR 1 UNIT 1B UNIT 3A UNIT 3A UNIT 3A UNIT 1A UNIT 2A UNIT 2A STAIR 2 UNIT 4A FLEX ROOM UNIT 2B UNIT 3A STAIR 1 ELEVATOR 2 WEST CORRIDOR EAST CORRIDOR IDF COMMON PATH OF TRAVEL PATH 4 COMMON PATH OF TRAVEL PATH 3 COMMON PATH OF TRAVEL PATH 2 COMMON PATH OF TRAVEL PATH 1 COMMON PATH OF TRAVEL PATH EXIT ACCESS TRAVEL PATH 4 EXIT ACCESS TRAVEL PATH 3 EXIT ACCESS TRAVEL PATH 2 EXIT ACCESS TRAVEL PATH 1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 4 : 0 6 P M G128 1648.001 AD/AO Checker CODE COMPLIANCE PATH OF TRAVEL THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 3RD FLOOR -EGRESS PLAN 1/8" = 1'-0" 2 4TH FLOOR -EGRESS PLAN COMMON PATH OF TRAVEL DISTANCE MAXIMUM = 125' (4TH FLOOR) MarkFrom RoomTo Room Length 1JANITOR 401WESTCORRIDOR 426 75'-0" 2 UNIT 3A 415WESTCORRIDOR 426 43'-5" 3UNIT 2A 414EAST CORRIDOR 425 31'-3" 4UNIT 2A 417EAST CORRIDOR 425 32'-1" 5UNIT 3A 423EAST CORRIDOR 425 84'-3" EXIT ACCESS TRAVEL DISTANCE MAXIMUM - 250' (4TH FLOOR) MarkFrom RoomTo Room Length 1JANITOR 401WESTCORRIDOR 426 75'-10" 2 UNIT 3A 415WESTCORRIDOR 426 134'-2" 3UNIT 2A 417EAST CORRIDOR 425 55'-10" 4UNIT 3A 423EAST CORRIDOR 425 87'-11" COMMON PATH OF TRAVEL DISTANCE MAXIMUM = 125' (3RD FLOOR) MarkFrom RoomTo Room Length 1JANITOR 301WESTCORRIDOR 326 75'-0" 2 UNIT 3A 315WESTCORRIDOR 326 43'-5" 3UNIT 2A 314EAST CORRIDOR 325 31'-3" 4UNIT 2A 317EAST CORRIDOR 325 32'-1" 5UNIT 3A 323EAST CORRIDOR 325 83'-7" EXIT ACCESS TRAVEL DISTANCE MAXIMUM 250' (3RD FLOOR) MarkFrom RoomTo Room Length 1JANITOR 301WESTCORRIDOR 326 75'-10" 2 UNIT 3A 315WESTCORRIDOR 326 134'-2" 3UNIT 2A 317EAST CORRIDOR 325 55'-8" 4UNIT 3A 323EAST CORRIDOR 325 87'-11" REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF.REF. REF. DN UP DN 1. CODE ANALYSIS BASED ON CODE REFERENCES INDICATED ON SHEET G031 2. SEE SHEET G2.0 FOR FIRE DEPT. ACCESS INFORMATION. 3. SEE SHEET G2.0 FOR SITE ACCESSIBILITY INFORMATION. 4. BUILDING ELEMENTS SHALL BE FIRE RESISTANCE RATED PER CBC TABLE 601. THIS INCLUDES THE STRUCTURAL FRAME, BEARING WALLS, FLOOR CONSTRUCTION, AND ROOF CONSTRUCTION. REFERENCE THE CODE ANALYSIS TABLE ON SHEET G031 5. EXTERIOR NON-BEARING WALLS SHALL BE FIRE RESISTANCE RATED BASED ON FIRE SEPARATION DISTANCE PER CBC TABLE 602. REFERENCE CODE ANALYSIS BUILDING PLANS ON SHEETS G121-G126 6. FIRE RESISTANCE RATED CONSTRUCTION SEPARATION OF ADJACENT SPACES SHALL BE PROVIDED PER CBC 701.1. THIS INCLUDES FIRE PARTITIONS, FIRE BARRIERS, AND FIRE WALLS. REFERENCE THE FIRE RESISTIVE INTERIOR WALLS LEGEND AND ALL BUILDING PLANS FOR LOCATIONS. 7. EXTERIOR WALLS SHALL BE RATED IN ACCORDANCE WITH TABLES CBC 601 AND 602. SEE BUILDING CODE ANALYSIS ON G031 8. BUILDING SHALL BE FULLY SPRINKLERED PER NFPA 13, SYSTEMS SERVING MORE THAN 100 SPRINKLERS SHALL BE SUPERVISED BY A REMOTE ALARM SYSTEM AS REQUIRED BY CFC. MONITORING SHALL INCLUDE VALVES; PUMPS; TANKS; WATER LEVELS AND TEMPERATURES; CRITICAL AIR PRESSURES; AND WATERFLOW. MONITORING SHALL BE ELECTRICALLY SUPERVISED BY A LISTED FIRE ALARM CONTROL UNIT. CFC 903.4. 9. ELEVATOR SHALL COMPLY WITH CBC 607. MIN. 80"X54" INTERIOR CLEARANCE FOR 84"X24" GURNEY WITH MAX. 5" RADIUS CORNERS PER CBC SECTION 3002.4.3A, SEE A6.20. 10. PROVIDE FIRE-BLOCKING IN CONCEALED SPACES AS REQUIRED PER CBC SEC 718.2 11. PROVIDE SMOKE ALARMS OR SMOKE DETECTORS IN R-2 OCCUPANCY (CBC SEC. 907.2.11), S.E.D. 12. PROVIDE CARBON MONOXIDE ALARMS (CBC SEC. 915), S.E.D. 13. FOR DIRECTIONAL ILLUMINATED EXIT SIGNAGE, PER CBC 1008, S.E.D. 14. FOR MORE INFORMATION FOR FIRE RATED DOORS, AND FRAMES SEE DOOR SCHEDULES, A7 SERIES SHEETS. 15. GROSS UNIT FLOOR AREAS INCLUDE EXTERIOR FACE OF EXTERIOR WALLS, CORRIDOR SIDE OF CORRIDOR WALLS, CENTER OF AIR GAP BETWEEN UNITS AND POPOUTS (WHERE OCCURS). 16. ALL ENTRANCES EXITS AT BUILDING SHALL BE MADE ACCESSIBLE PER CBC CHAPTER 11B CODE ANALYSIS NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND UNIT 3A UNIT 1A UNIT 2A UNIT 2B UNIT 3A UNIT 4A UNIT 2A UNIT 3A UNIT 3A UNIT 1B UNIT 3A TRASH JANITOR UNIT 2B LAUNDRY ROOM ELEVATOR 1 FLEX ROOM STAIR 1 ELEVATOR 2 WEST CORRIDOR EAST CORRIDOR STAIR 2 DEAD E ND CORRIDOR LENGTH 43'-10" IDF DEAD E ND CORRIDOR LENGTH 49'-10" COMMON PATH OF TRAVEL PATH 4 COMMON PATH OF TRAVEL PATH 3 COMMON PATH OF TRAVEL PATH 2 COMMON PATH OF TRAVEL PATH 1 COMMON PATH OF TRAVEL PATH EXIT ACCESS TRAVEL PATH 4 EXIT ACCESS TRAVEL PATH 3 EXIT ACCESS TRAVEL PATH 2 EXIT ACCESS TRAVEL PATH 1 JANITOR TRASH UNIT 3A UNIT 2B FLEX ROOM ELEVATOR 1 STAIR 1 UNIT 1B ELEVATOR 2 UNIT 3A UNIT 3A UNIT 2A STAIR 2 UNIT 4A UNIT 3A UNIT 2B FLEX ROOM UNIT 2A UNIT 1A UNIT 3A DEAD E ND CORRIDOR LENGTH 43'-10" WEST CORRIDOR EAST CORRIDOR IDF COMMON PATH OF TRAVEL PATH 4 COMMON PATH OF TRAVEL PATH 3 COMMON PATH OF TRAVEL PATH 2 COMMON PATH OF TRAVEL PATH 1 COMMON PATH OF TRAVEL PATH EXIT ACCESS TRAVEL PATH 4 EXIT ACCESS TRAVEL PATH 3 EXIT ACCESS TRAVEL PATH 2 EXIT ACCESS TRAVEL PATH 1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 3 4 : 2 8 P M G129 1648.001 AD/AO Checker CODE COMPLIANCE PATH OF TRAVEL THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 5TH FLOOR -EGRESS PLAN 1/8" = 1'-0" 2 6TH FLOOR -EGRESS PLAN COMMON PATH OF TRAVEL DISTANCE MAXIMUM = 125' (5TH FLOOR) Mark From Room To Room Length 1JANITOR 501WESTCORRIDOR 526 75'-0" UNIT 3A 515WESTCORRIDOR 526 43'-5" 3UNIT 2A 514EAST CORRIDOR 525 31'-3" 4UNIT 2A 517EAST CORRIDOR 525 32'-1" 5UNIT 3A 523EAST CORRIDOR 525 84'-3" EXIT ACCESS TRAVEL DISTANCE MAXIMUM 250' (5TH FLOOR) MarkFrom RoomTo Room Length 1JANITOR 501WESTCORRIDOR 526 75'-10" UNIT 3A 515WESTCORRIDOR 526 134'-2" 3UNIT 2A 517EAST CORRIDOR 525 55'-8" 4UNIT 3A 523EAST CORRIDOR 525 87'-11" COMMON PATH OF TRAVEL DISTANCE MAXIMUM = 125' (6TH FLOOR) MarkFrom RoomTo Room Length JANITOR 601WESTCORRIDOR 626 75'-0" UNIT 3A 615WESTCORRIDOR 626 43'-5" UNIT 2A 614EAST CORRIDOR 625 31'-3" UNIT 2A 617EAST CORRIDOR 625 32'-1" UNIT 3A 623EAST CORRIDOR 625 84'-3" COMMON PATH OF TRAVEL DISTANCE MAXIMUM = 125' (6TH FLOOR) MarkFrom RoomTo Room Length JANITOR 601WESTCORRIDOR 626 75'-0" UNIT 3A 615WESTCORRIDOR 626 43'-5" UNIT 2A 614EAST CORRIDOR 625 31'-3" UNIT 2A 617EAST CORRIDOR 625 32'-1" UNIT 3A 623EAST CORRIDOR 625 84'-3" REVISIONS
UP UP 60" 60"x60" 60"x60" 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 A A 16 16 17 17 B B D D M L L 14 5 2 A511 1 A521 1 A511 A521 A512 1 A522 1 A512 2 A522 2 DUMPSTER ROOM 101 GARAGE 103 FLEX SPACE 117 MECHANICAL 125 MPOE 123 ERRCS 120 FIRE PUMP 121 ELECTRICAL 105 STAIR 1 107 CORRIDOR 109 ELEVATOR 2 111 R.R. 110 OFFICE 113 OFFICE 114 BIKE ROOM 115 ELEV. EQUIPM. 112 STAIR 2 119 119 121 123 103-C 105-A 125-A 101-A 103-B 103-A 101-B 107 125-B 120 115 112 105-B 117 110 104 109-B 114 113 ELEV. EQUIPM. 104 ELEVATOR 1 106 A221.3 1 A221.3 4 A221.1 A221.4 S3 S4 S2 S1 S5 S1 S7 117-A 117-B 109-A 109-C 2 A611 A611 A524 2 A524 3 A524 1 PA PA PB PB PC PC A811 1 2 3 4 A631 1 A632 1 A641 A641 1 7 A642 A642 1 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 2 : 3 3 P M A211.1 1648.001 AD/AO Checker ANNOTATION PLANGROUND FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 ANNOTATION PLAN -GROUND FLOOR KEYNOTE LEGEND Key Value Keynote Text REVISIONS
UP UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 A A 16 16 17 17 B B D D M L L 14 5 2 DUMPSTER ROOM 101 GARAGE 103 FLEX SPACE 117 MECHANICAL 125 MPOE 123 ERRCS 120 FIRE PUMP 121 ELECTRICAL 105 STAIR 1 107 CORRIDOR 109 ELEVATOR 2 111 R.R. 110 OFFICE 113 OFFICE 114 BIKE ROOM 115 ELEV. EQUIPM. 112 STAIR 2 119 ELEV. EQUIPM. 104 ELEVATOR 1 106 174'-0" 25'-0" 199'-0" 25'-0" 6'-0" 64'-9 1/2" 95'-9 1/2" 199'-0" 15'-10" 27'-3" 121'-3" 9'-8" 25'-0" 98'-9" 25'-0" 6'-0" 64'-9 1/2" 2'-11 1/2" PA PB PB PC PC 15'-0 1/4" P1 P1 P2 P2 P3 P3 P4 P4 P5 P6 14'-11 13/16" 9'-10" 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 2 : 4 1 P M A211.2 1648.001 AD/AO Checker DIMENSION PLANGROUND FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 DIMENSION PLAN -GROUND FLOOR REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. DN REF. REF. UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F 224 218 216 222 219 203 201 202 207 221 223 208 209 205 213 215 210-A 214 217 204 JANITOR 201 TRASH 203 UNIT 2B 202 UNIT 3A 205 BIKE ROOM 204 ELEVATOR 1 206 STAIR 1 207 WEST CORRIDOR 226 UNIT 1B 209 ELEVATOR 2 211 UNIT 3A 213 11B MOBILITY COMMUNITY ROOM 210 UNIT 1A 212 11B MOBILITY UNIT 2A 214 11B MOBILITY UNIT 3A 215 UNIT 2A 217 MAINTENANCE 222 STAIR 2 219 UNIT 4A 221 11B MOBILITY UNIT 3A 223 UNIT 2B 224 EAST CORRIDOR 225 R.R. 216 IDF 220 STORAGE 208 A511 1 A521 1 A511 A521 A512 1 A522 1 A512 2 A522 2 A513 3 A513 1 A513 2 R.R. 218 220 210-B C 213A 219-1 E 213-3 E 209E 215E 217-1 C 209B 213C 213-1 C 215-4 C 215-3 C 215-1 C 221-5 C 221C 221C 221B 223C 223E 221E 223P 224F 224-1 P 214-2 P 212- F 212F 214-1 F 202-3 E 205-3 C 205-1 C 205-2 Q 214C 217C 217-2 D 209C 223-1 P 224-2 P 202-1 P 202225 226 A221.6 1 A221.7 4 A221.7 1 E C 227 A 307-2 A 307C 2052 A611 A611 212 A524 2 A524 3 A524 1 A821 2 1 A821 3 4 5 6 A821 19 A821 21 20 24 22 23 A811 5 A811 9 6 7 8 10 11 12 A822 2 1 A822 3 4 5 6 A822 13 A822 9 10 11 12 14 15 16 A822 7 A823 1 2 A823 3 4 5 6 A823 7 8 10 A821 13 A821 15 14 16 17 18 A822 20 19 18 17 A822 21 22 A821 12 A821 7 10 11 A811 14 13 A631 2 A632 A641 7 A642 A641 2 A642 2 A524 4 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 2 : 5 3 P M A212.1 1648.001 AD/AO Checker ANNOTATION PLAN2ND FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 ANNOTATION PLAN -2ND FLOOR KEYNOTE LEGEND Key Value Keynote Text REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. DN REF. REF. UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F JANITOR 201 TRASH 203 UNIT 2B 202 UNIT 3A 205 BIKE ROOM 204 ELEVATOR 1 206 STAIR 1 207 WEST CORRIDOR 226 UNIT 1B 209 ELEVATOR 2 211 UNIT 3A 213 11B MOBILITY COMMUNITY ROOM 210 UNIT 1A 212 11B MOBILITY UNIT 2A 214 11B MOBILITY UNIT 3A 215 UNIT 2A 217 MAINTENANCE 222 STAIR 2 219 UNIT 4A 221 11B MOBILITY UNIT 3A 223 UNIT 2B 224 EAST CORRIDOR 225 R.R. 216 IDF 220 STORAGE 208 E C R.R. 218 199'-0" 25'-0" 6'-0" 18'-9" 6'-3" 37'-10" 22'-5 11/16" 26'-8 5/16" 6'-3" 18'-9" 6'-0" 25'-0" 95'-9 1/2" 25'-0" 1'-8" 4'-4" 5'-4" 12'-1" 8'-0 1/2" 23'-11 1/2" 3'-8" 7'-7 1/2" 4'-1" 199'-0" 15'-10" 9'-2" 6'-0" 12'-1" 44'-1" 43'-11 5/16" 33'-2 11/16" 3'-8" 6'-0" 25'-0" 98'-9" 25'-0" 6'-0" 17'-5" 6'-3 1/2" 1'-9" 27'-7 1/2" 11'-8 1/2" 2'-11 1/2" 7'-0" P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 3 : 0 2 P M A212.2 1648.001 AD/AO Checker DIMENSION PLAN2ND FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 DIMENSION PLAN -2ND FLOOR REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F 319 303 301 302 307 321 324 323 309 305 313 315 310 314 317 316 JANITOR 301 TRASH 303 UNIT 2B 302 UNIT 3A 305 LAUNDRY 304 ELEVATOR 1 306 STAIR 1 307 WEST CORRIDOR 326 UNIT 1B 309 ELEVATOR 2 311 UNIT 3A 313 11B MOBILITY UNIT 3A 310 UNIT 1A 312 11B MOBILITY UNIT 2A 314 11B MOBILITY UNIT 3A 315 UNIT 2A 317 TEEN ROOM 316 STAIR 2 319 UNIT 4A 321 11B MOBILITY UNIT 3A 323 UNIT 2B 324 EAST CORRIDOR 325 A511 1 A521 1 A511 2 A521 2 A512 1 A522 1 A512 2 A522 2 304 IDF 320 320 E 313E 315-2 E 321-3 E 324E 312E 314-1 E 302C 313-2 C 313-1 C 315-4 C 315C 315-1 C 317C 317C 321-5 C 321-4 C 321-2 C 323-2 C 323-1 C 324C 314C 312C 302C 305-1 C 305-2 C 305-4 D 309B 314C 309E 305-3 E 310E 323-3 C 321-1 E 317-1 B 310-1 C 310-3 C 310A 301B 323-4 B 313A 325-2 A 325A 326-1 A 326-2 C 324C 302E 309-2 A221.8 4 A221.8 1 A221.6 E C A523 3 A523 1 A523 2 327 A 307A 307-1 2 A611 1 A611 312 A524 2 A524 3 A524 1 7 A641 7 A642 A631 A642 3 A641 3 A632 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 3 : 1 4 P M A213.1 1648.001 AD/AO Checker ANNOTATION PLAN3RD FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 ANNOTATION PLAN -3RD FLOOR KEYNOTE LEGEND Key Value Keynote Text REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F JANITOR 301 TRASH 303 UNIT 2B 302 UNIT 3A 305 LAUNDRY 304 ELEVATOR 1 306 STAIR 1 307 WEST CORRIDOR 326 UNIT 1B 309 ELEVATOR 2 311 UNIT 3A 313 11B MOBILITY UNIT 3A 310 UNIT 1A 312 11B MOBILITY UNIT 2A 314 11B MOBILITY UNIT 3A 315 UNIT 2A 317 TEEN ROOM 316 STAIR 2 319 UNIT 4A 321 11B MOBILITY UNIT 3A 323 UNIT 2B 324 EAST CORRIDOR 325 E C 199'-0" 25'-0" 6'-0" 18'-9" 6'-3" 37'-10" 22'-5 11/16" 26'-8 5/16" 6'-3" 18'-9" 6'-0" 25'-0" 95'-9 1/2" 25'-0" 1'-8" 4'-4" 5'-4" 12'-1" 8'-0 1/2" 23'-11 1/2" 3'-8" 7'-7 1/2" 4'-1" 199'-0" 15'-10" 9'-2" 6'-0" 12'-1" 44'-1" 43'-11 5/16" 33'-2 11/16" 3'-8" 6'-0" 25'-0" 98'-9" 25'-0" 6'-0" 17'-5" 6'-3 1/2" 1'-9" 27'-7 1/2" 11'-8 1/2" 2'-11 1/2" IDF 320 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 3 : 2 4 P M A213.2 1648.001 AD/AO Checker DIMENSION PLAN3RD FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 DIMENSION PLAN -3RD FLOOR REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F JANITOR 401 TRASH 403 UNIT 2B 402 UNIT 3A 405 FLEX ROOM 404 ELEVATOR 1 406 STAIR 1 407 WEST CORRIDOR 426 UNIT 1B 409 ELEVATOR 2 411 UNIT 3A 413 11B MOBILITY UNIT 3A 410 UNIT 1A 412 11B MOBILITY UNIT 2A 414 11B MOBILITY UNIT 3A 415 UNIT 2A 417 FLEX ROOM 416 STAIR 2 419 UNIT 4A 421 11B MOBILITY UNIT 3A 423 UNIT 2B 424 419 403 401 402 407 421 424 423 409 405 413 415 410 414 417 416 EAST CORRIDOR 425 A511 1 A521 1 A511 A521 A512 1 A522 1 A512 2 A522 2 404 IDF 420 420 E 415E 421E 424E 412E 414-1 E 402C 413C 413-1 C 415-4 C 415-3 C 415C 417-3 C 417-2 C 421C 421C 421-2 C 423-2 C 424-3 C 414-2 C 412C 405-1 C 405-2 C 405-4 B 414C 409-1 E 405-3 E 410E 423-3 C 421E 417-1 B 410C 410C 410-4 B 423E 413-3 B 413A 425-2 A 425A 426-1 A 426D 409A 401-1 C 423-1 C 424-2 C 402-1 C 402E 409A221.6 A221.9 1 E C A523 3 A523 1 A523 2 427 2 A611 A611 412 A524 2 A524 3 A524 1 A641 7 A642 A631 4 A641 4 A642 A632 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 3 : 3 5 P M A214.1 1648.001 AD/AO Checker ANNOTATION PLAN4TH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 ANNOTATION PLAN -4TH FLOOR KEYNOTE LEGEND Key Value Keynote Text REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F JANITOR 401 TRASH 403 UNIT 2B 402 UNIT 3A 405 FLEX ROOM 404 ELEVATOR 1 406 STAIR 1 407 WEST CORRIDOR 426 UNIT 1B 409 ELEVATOR 2 411 UNIT 3A 413 11B MOBILITY UNIT 3A 410 UNIT 1A 412 11B MOBILITY UNIT 2A 414 11B MOBILITY UNIT 3A 415 UNIT 2A 417 FLEX ROOM 416 STAIR 2 419 UNIT 4A 421 11B MOBILITY UNIT 3A 423 UNIT 2B 424 EAST CORRIDOR 425 E C 199'-0" 25'-0" 6'-0" 18'-9" 6'-3" 37'-10" 22'-5 11/16" 26'-8 5/16" 6'-3" 18'-9" 6'-0" 25'-0" 95'-9 1/2" 25'-0" 1'-8" 4'-4" 5'-4" 12'-1" 8'-0 1/2" 23'-11 1/2" 3'-8" 7'-7 1/2" 4'-1" 199'-0" 15'-10" 9'-2" 6'-0" 12'-1" 44'-1" 43'-11 5/16" 33'-2 11/16" 3'-8" 6'-0" 25'-0" 98'-9" 25'-0" 6'-0" 17'-5" 6'-3 1/2" 1'-9" 27'-7 1/2" 11'-8 1/2" 2'-11 1/2" IDF 420 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 3 : 4 6 P M A214.2 1648.001 AD/AO Checker DIMENSION PLAN4TH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 DIMENSION PLAN -4TH FLOOR REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F 519 503 501 502 507 521 524 523 509 505 513 515 510 514 517 516 JANITOR 501 TRASH 503 UNIT 2B 502 UNIT 3A 505 LAUNDRY ROOM 504 ELEVATOR 1 506 STAIR 1 507 WEST CORRIDOR 526 UNIT 1B 509 ELEVATOR 2 511 UNIT 3A 513 11B MOBILITY UNIT 3A 510 UNIT 1A 512 11B MOBILITY UNIT 2A 514 11B MOBILITY UNIT 3A 515 UNIT 2A 517 FLEX ROOM 516 STAIR 2 519 UNIT 4A 521 11B MOBILITY UNIT 3A 523 UNIT 2B 524 EAST CORRIDOR 525 A511 1 A521 1 A511 A521 A512 1 A522 1 A512 2 A522 2 504 IDF 520 520 E 513-3 E 515E 521-3 E 524E 512E 514-1 E 502-3 C 513C 513-1 C 515-4 C 515-3 C 515-1 C 517-3 C 517-2 C 521C 521-4 C 521-2 C 523-2 C 524-3 C 514-2 C 512C 505C 505C 505B 514C 509-1 E 505E 510E 523-3 C 521-1 E 517-1 B 510- C 510C 510-4 B 523-4 B 513A 525A 525-1 A 526A 526D 509-3 A 501-1 C 523-1 C 524-2 C 502-1 C 502E 509A221.6 A221.9 1 E C A523 3 A523 1 A523 2 527 2 A611 A611 512 A524 2 A524 3 A524 1 A641 7 A642 A631 A642 A641 5 A632 5 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 3 : 5 8 P M A215.1 1648.001 AD/AO Checker ANNOTATION PLAN5TH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 ANNOTATION PLAN -5TH FLOOR KEYNOTE LEGEND Key Value Keynote Text REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. DN UP DN UP 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F JANITOR 501 TRASH 503 UNIT 2B 502 UNIT 3A 505 LAUNDRY ROOM 504 ELEVATOR 1 506 STAIR 1 507 WEST CORRIDOR 526 UNIT 1B 509 ELEVATOR 2 511 UNIT 3A 513 11B MOBILITY UNIT 3A 510 UNIT 1A 512 11B MOBILITY UNIT 2A 514 11B MOBILITY UNIT 3A 515 UNIT 2A 517 FLEX ROOM 516 STAIR 2 519 UNIT 4A 521 11B MOBILITY UNIT 3A 523 UNIT 2B 524 EAST CORRIDOR 525 E C 199'-0" 25'-0" 6'-0" 18'-9" 6'-3" 37'-10" 22'-5 11/16" 26'-8 5/16" 6'-3" 18'-9" 6'-0" 25'-0" 95'-9 1/2" 25'-0" 1'-8" 4'-4" 5'-4" 12'-1" 8'-0 1/2" 23'-11 1/2" 3'-8" 7'-7 1/2" 4'-1" 199'-0" 15'-10" 9'-2" 6'-0" 12'-1" 44'-1" 43'-11 5/16" 33'-2 11/16" 3'-8" 6'-0" 25'-0" 98'-9" 25'-0" 6'-0" 17'-5" 6'-3 1/2" 1'-9" 27'-7 1/2" 11'-8 1/2" 2'-11 1/2" IDF 520 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 4 : 0 9 P M A215.2 1648.001 AD/AO Checker DIMENSION PLAN5TH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 DIMENSION PLAN -5TH FLOOR REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF.REF. REF. DN UP DN 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F 609 621 619 603 601 602 607 624 623 605 613 615 610 614 617 616 JANITOR 601 TRASH 603 UNIT 2B 602 UNIT 3A 605 FLEX ROOM 604 ELEVATOR 1 606 STAIR 1 607 WEST CORRIDOR 626 UNIT 1B 609 ELEVATOR 2 611 UNIT 3A 613 11B MOBILITY UNIT 3A 610 UNIT 1A 612 11B MOBILITY UNIT 2A 614 11B MOBILITY UNIT 3A 615 UNIT 2A 617 FLEX ROOM 616 STAIR 2 619 UNIT 4A 621 11B MOBILITY UNIT 3A 623 UNIT 2B 624 EAST CORRIDOR 625 A511 1 A521 1 A511 A521 A512 1 A522 1 A512 2 A522 2 604 IDF 620 620 E 613-3 E 615E 621E 624E 612E 614-1 E 602-3 C 613C 613-1 C 615-4 C 615-3 C 615-1 C 617-3 C 617-2 C 621C 621-4 C 621-2 C 623-2 C 624-3 C 614-2 C 612C 605-1 C 605-2 C 605-4 B 614C 609-1 E 605-3 E 610E 623-3 C 621-1 E 617-1 B 610C 610C 610-4 A 625-2 B 623B 613A 625A 626-1 A 626D 609A 601-1 C 623-1 C 624-2 C 602-1 C 602E 609A221.6 2 A221.9 E C A523 3 A523 1 A523 2 627 2 A611 A611 612 A524 2 A524 3 A524 1 A641 7 A642 A631 6 A641 A642 6 A632 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 4 4 : 2 1 P M A216.1 1648.001 AD/AO Checker ANNOTATION PLAN6TH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 ANNOTATION PLAN -6TH FLOOR KEYNOTE LEGEND Key Value Keynote Text REVISIONS
REF. REF. REF. REF. REF. REF. REF. REF. REF. REF. REF.REF. REF. DN UP DN 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL STRUCTURAL COLUMNS, S.S.D. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER FE 101 FIRE SPRINKLER SYSTEM STAND PIPE, S.P.D. SPOT ELEVATION xx.x % SLOPE DIRECTION CONCRETE WALL, S.S.D. FLOOR/DECK DRAIN ROOF DRAIN S.P.D. SCUPPER DOWNSPOUT D.S. PTAC UNIT - ) 101 A xxx-xx 1W4C MOP SINK, S.P.D. UTILITY SINK, S.P.D. TRUNCATED DOMES BUILDING PLAN SYMBOLS 1 1 3 3 A A 4 4 7 12 15 15 16 16 17 17 B B D D H H J J K M L L 6 9 10 13 G 14 11 8 5 2 F F JANITOR 601 TRASH 603 UNIT 2B 602 UNIT 3A 605 FLEX ROOM 604 ELEVATOR 1 606 STAIR 1 607 WEST CORRIDOR 626 UNIT 1B 609 ELEVATOR 2 611 UNIT 3A 613 11B MOBILITY UNIT 3A 610 UNIT 1A 612 11B MOBILITY UNIT 2A 614 11B MOBILITY UNIT 3A 615 UNIT 2A 617 FLEX ROOM 616 STAIR 2 619 UNIT 4A 621 11B MOBILITY UNIT 3A 623 UNIT 2B 624 EAST CORRIDOR 625 E C 199'-0" 25'-0" 6'-0" 18'-9" 6'-3" 37'-10" 22'-5 11/16" 26'-8 5/16" 6'-3" 18'-9" 6'-0" 25'-0" 95'-9 1/2" 25'-0" 1'-8" 4'-4" 5'-4" 12'-1" 8'-0 1/2" 23'-11 1/2" 3'-8" 7'-7 1/2" 4'-1" 199'-0" 15'-10" 9'-2" 6'-0" 12'-1" 44'-1" 43'-11 5/16" 33'-2 11/16" 3'-8" 6'-0" 25'-0" 98'-9" 25'-0" 6'-0" 17'-5" 6'-3 1/2" 1'-9" 27'-7 1/2" 11'-8 1/2" 2'-11 1/2" IDF 620 P1 P2 P3 P4 P5 P6 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 2 : 2 1 P M A216.2 1648.001 AD/AO Checker DIMENSION PLAN6TH FLOOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 DIMENSION PLAN -6TH FLOOR REVISIONS

ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.)

4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS.

6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS.

PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL)

54" 44" 60" 54" 44" 60" 60"x60" 60"x60" 60" 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3.
BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1 1 A A B B D D 5 2 CORRIDOR ELEVATOR 2 R.R. OFFICE OFFICE BIKE ROOM 115 ELEV. EQUIPM. 1 A611 PA PA 7 A641 7 A642 P1 P2 7 A631 1 1 A A B B 5 2 CORRIDOR ELEVATOR 2 R.R. OFFICE OFFICE BIKE ROOM 115 ELEV. EQUIPM. STAIR 1 15'-4 1/2" 27'-7" 8'-8 61/128" 13'-8 3/128" 15'-5" 10'-2 1/2" 7'-2 7/8" 15'-0 1/8" 15'-5" 10'-3 1/2" 12'-0 1/2" 6'-0" 80'-9" 16'-2" 8'-10" 1'-4" 26'-4" 6'-7 3/8" 1'-11 163/256" 22'-4 93/256" 8" 25'-0" PA PA P1 P2 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 2 : 3 2 P M A221.1 1648.001 AD/AO Checker ENLARGED PLANSLOBBY THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 1 ANNOTATION PLAN -LOBBY, OFFICES, BIKE ROOM 1/4" = 1'-0" 2 DIMENSION PLAN -LOBBY, OFFICES, BIKE ROOM REVISIONS
7.

AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.)

4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS.

6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE

54" 44" 60" 54" 44" 60" REF. REF. 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS.
ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.)
DIMENSIONS
2.
3. ALL
SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND CORRIDOR ELEVATOR 2 ELEV. EQUIPM. OFFICE OFFICE R.R. STAIR 1 7 A641 7 A642 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 2 : 3 7 P M A221.2 1648.001 AD/AO Checker ENLARGED PLANSLOBBY THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 2 RCP -LOBBY, OFFICES, BIKE ROOM REVISIONS

WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.)

4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS.

6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE

54" 44" 60" 54" 44" 60" 60"x60" 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS.
ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.)
ALL DIMENSIONS AT
2.
3.
SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1 1 L L DUMPSTER ROOM PC 1 1 L L DUMPSTER ROOM 20'-8" 17'-8" PC DUMPSTER ROOM 1 1 ELECTRICAL A611 PB 1 1 ELECTRICAL 22'-2" 14'-9 1/2" PB ELECTRICAL 2 A611 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 2 : 5 0 P M A221.3 1648.001 AD/AO Checker ENLARGED PLANSELECTRICAL & DUMPSTER THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 1 ANNOTATION PLAN -DUMPSTER ROOM 1/4" = 1'-0" 2 DIMENSION PLAN -DUMPSTER ROOM 1/4" = 1'-0" 3 RCP -DUMPSTER ROOM 1/4" = 1'-0" 4 ANNOTATION PLAN -ELECTRICAL ROOM 1/4" = 1'-0" 5 DIMENSION PLAN -ELECTRICAL ROOM 1/4" = 1'-0" 6 RCP -ELECTRICAL ROOM REVISIONS

& DOORS ARE TO THE CENTERLINE (U.O.N.)

4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS

5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS.

6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE

54" 44" 60" 54" 44" 60" REF. 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS
SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND A A 16 16 17 17 D D MECHANICAL MPOE ERRCS FIRE PUMP PA PA P6 A A 16 16 17 17 D D MECHANICAL MPOE ERRCS FIRE PUMP 10'-8" 6'-1 5/8" 14'-2 3/8" 31'-0" 8 1/4" 24'-9" 25'-5 1/4" 20'-5 1/2" 4'-6 1/2" 25'-0" PA PA P6 MECHANICAL MPOE ERRCS FIRE PUMP 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 2 : 5 5 P M A221.4 1648.001 AD/AO Checker ENLARGED PLANSUTILITY THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 1 ANNOTATION PLAN -GROUND FLOOR 1/4" = 1'-0" 2 ANNOTATION PLAN -GROUND FLOOR 1/4" = 1'-0" 3 RCP -GROUND FLOOR REVISIONS
54" 44" 60" 54" 44" 60" 60"x60" 60"x60" REF. 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND D D 6 6 9 9 F F COMMUNITY ROOM STORAGE 2 A611 A524 4 P1 P2 D D H H 6 9 9 F F COMMUNITY ROOM STORAGE 15'-9 1/2" 9'-9 1/2" 25'-7" 44'-0 1/2" 1/2" 44'-1" 5'-5 1/2" 2'-0" 3'-5 1/2" 1/2" 43'-11" 1 1/2" 10'-11" 11'-3 1/2" 3'-0" 18'-8 1/2" 44'-1" P1 P2 COMMUNITY ROOM STORAGE 2 A611 7 A641 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 3 : 0 9 P M A221.5 1648.001 AD/AO Checker ENLARGED PLANSCOMMUNITY THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 1 ANNOTATION PLAN -COMMUNITY ROOM 1/4" = 1'-0" 2 DIMENSION PLAN -COMMUNITY ROOM 1/4" = 1'-0" 3 RCP -COMMUNITY ROOM REVISIONS

AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.)

4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS.

6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE

54" 44" 60" 54" 44" 60" 60"x60" 60" 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS
SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 1 1 3 3 K K I I JANITOR TRASH 1 1 3 3 K K I I 1/2" 11'-8 1/2" 11'-9" 7'-8" 3'-3 1/2" 4'-7" 3'-5 1/2" 6'-0" 25'-0" 1/2" 7'-0" 4'-3" 11'-3" TRASH JANITOR TRASH JANITOR 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 3 : 1 5 P M A221.6 1648.001 AD/AO Checker ENLARGED PLANSTRASH & JANITOR THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/4" = 1'-0" 1 ANNOTATION PLAN -TRASH & JANITOR ROOM -FLOORS 2 TO 6 1/4" = 1'-0" 2 DIMENSION PLAN -TRASH & JANITOR ROOM -FLOORS 2 TO 6 1/4" = 1'-0" 3 RCP -TRASH & JANITOR ROOM -FLOORS 2 TO 6 REVISIONS

3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.)

4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS

ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS.

6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS.

7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE

9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED

54" 44" 60" 54" 44" 60" 60"x60" 60"x60" 60"x60" 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.)
5.
SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 4 4 D D 6 6 F F BIKE ROOM ELEVATOR 1 E 2 A611 A611 7 A641 4 4 D D 6 6 F F 4'-7 1/2" 12'-9" 1/2" 17'-5" 18'-8 1/2" 1/2" 18'-9" 8'-1 1/2" 10'-7" 1/2" 18'-9" BIKE ROOM ELEVATOR 1 E BIKE ROOM ELEVATOR 1 A611 7 A641 15 15 D D 13 13 F F MAINTENANCE R.R. IDF R.R. 2 A611 A632 P5 15 15 D D 13 13 F F MAINTENANCE R.R. IDF 1/2" 8'-10" 8'-6 1/2" 17'-5" 1/2" 7'-1" 7'-2 1/2" 4'-5" 18'-9" R.R. P5 MAINTENANCE R.R. IDF R.R. 2 A611 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 3 : 3 7 P M A221.7 1648.001 AD/AO Checker ENLARGED PLANSBIKE & MAINTENANCE THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 4 ANNOTATION PLAN -BIKE ROOM -2ND FLOOR 1/4" = 1'-0" 5 DIMENSION PLAN -BIKE ROOM -2ND FLOOR 1/4" = 1'-0" 6 RCP -BIKE ROOM -2ND FLOOR 1/4" = 1'-0" 1 ANNOTATION PLAN -MAINTENANCE & RESTROOMS 1/4" = 1'-0" 2 DIMENSION PLAN -MAINTENANCE & RESTROOMS 1/4" = 1'-0" 3 RCP -MAINTENANCE & RESTROOMS REVISIONS

DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS

ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS.

PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE

SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL)

54" 44" 60" 54" 44" 60" 60"x60" 60"x60" 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL
BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 4 4 D D 6 6 F F LAUNDRY ELEVATOR 1 2 A611 1 A611 A641 7 A642 4 4 D D 6 6 F F LAUNDRY ELEVATOR 1 1/2" 12'-9" 4'-7 1/2" 17'-5" 8'-1 1/2" 10'-7" 1/2" 18'-9" 8'-3" 5'-6 1/2" 1'-7" 2'-0" 1/2" 17'-4 1/2" 17'-5" LAUNDRY ELEVATOR 1 2 A611 A641 15 15 D D 13 13 F F TEEN ROOM IDF 2 A611 P5 15 15 D D 13 13 F F TEEN ROOM 1/2" 17'-4 1/2" 17'-5" 18'-9" 1/2" 14'-3 1/2" 4'-5" 9'-1 1/2" 8'-3" IDF P5 TEEN ROOM IDF 2 A611 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 3 : 5 8 P M A221.8 1648.001 AD/AO Checker ENLARGED PLANSLAUNDRY & TEEN THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 4 ANNOTATION PLAN -LAUNDRY -3RD FLOOR 1/4" = 1'-0" 5 DIMENSION PLAN -LAUNDRY -3RD FLOOR 1/4" = 1'-0" 6 RCP -LAUNDRY -3RD FLOOR 1/4" = 1'-0" 1 ANNOTATION PLAN -TEEN ROOM 1/4" = 1'-0" 2 DIMENSION PLAN -TEEN ROOM 1/4" = 1'-0" 3 RCP -TEEN ROOM REVISIONS
5.
7.
9.

DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.) 4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS

ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS. 6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS.

PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE

SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL)

54" 44" 60" 54" 44" 60" 60"x60" 60"x60" 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS. 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL
BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 4 4 D D 6 6 F F FLEX ROOM ELEVATOR 1 2 A611 A611 7 A641 4 4 D D 6 6 F F FLEX ROOM ELEVATOR 1 10'-2" 3'-4" 1'-7" 2'-0" 3 1/2" 17'-5" 8'-1 1/2" 10'-7" 1/2" 18'-9" 4'-7 1/2" 12'-9" 1/2" 17'-5" FLEX ROOM ELEVATOR 1 2 A611 7 A641 15 15 D D 13 13 F F FLEX ROOM 17'-4 1/2" 1/2" 17'-5" 18'-9" 1/2" 14'-3 1/2" 4'-5" 8'-6 1/2" 8'-10" IDF P5 15 15 D D 13 13 F F FLEX ROOM IDF 2 A611 P5 FLEX ROOM IDF 2 A611 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 4 : 2 0 P M A221.9 1648.001 AD/AO Checker ENLARGED PLANSFLEX & MAINTENANCE THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 4 ANNOTATION PLAN -FLEX ROOM -WEST -FLOORS 4 & 6 1/4" = 1'-0" 5 DIMENSION PLAN -FLEX ROOM -WEST -FLOORS 4 & 6 1/4" = 1'-0" 6 RCP -FLEX ROOM -WEST -FLOORS 4 & 6 1/4" = 1'-0" 2 DIMENSION PLAN -FLEX ROOM -EAST -FLOORS 4 TO 6 1/4" = 1'-0" 1 ANNOTATION PLAN -FLEX ROOM -EAST -FLOORS 4 TO 6 1/4" = 1'-0" 3 RCP -FLEX ROOM -EAST -FLOORS 4 TO 6 REVISIONS
5.
7.
9.

WINDOWS & DOORS ARE TO THE CENTERLINE (U.O.N.)

4. FOR STUD SIZES AND MATERIAL SEE ALL A2 SERIES PLANS FOR WALL TAGS 5. ALL SHEATHING SURFACE PLANES TO BE CONTINUOUS. ALL GYPSUM BOARD PARTITIONS SHALL BE TAPED AND SANDED SMOOTH WITH NO VISIBLE JOINTS.

6. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" MINIMUM AND ALL EXTERIOR DOOR JAMBS ON HINGE

54" 44" 60" 54" 44" 60" 60"x60" 1. ALL INTERIOR CLEAR DIMENSIONS TO FACE OF FINISH (U.O.N.) 2. SEE GENERAL ACCESSIBILITY SHEETS FOR EQUIPMENT MOUNTING 3. FOR FINISH INFORMATION SEE INTERIOR ELEVATIONS 4. S.E.D. AND S.P.D. FOR ADDITIONAL INFORMATION RELATED TO KITCHEN EQUIPMENT ENLARGED PLAN NOTES KITCHEN SINK W/ GARBAGE DISPOSAL AND FAUCET, S.P.D. LAVATORY FAUCET PER CBC 402.12. PROVIDE SOLID BACKING & INSULATE EXPOSED PIPES. LOW FLOW TOILET W/ 17" MAX HT. ELONGATED BOWL, PER CBC 402.2, S.P.D. LOW FLOW URINAL, S.P.D. TOILET PAPER DISPENSER SEAT COVER DISPENSER SANITARY NAPKIN DISPOSAL 42" SIDE AND 36" REAR GRAB BARS WALL MOUNTED SOAP DISPENSER PAPER TOWEL DISPENSER DISPOSAL WASHER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE HOT AND COLD WATER SUPPLY AND WASTE LINE S.P.D. DRYER -FRONT LOADING W/ CONTROLS AT MIN. 15" AND MAX. 48" HEIGHT. PROVIDE SMOOTH METAL VENT TO EXTERIOR. S.M.D. ELECTRICAL PANEL, S.E.D. WALL TYPE -SEE SHEET G301 FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR A WINDOW TAG DOOR TAG W 6 A 5'-0" DIAMETER WHEELCHAIR CLEARANCE CLEAR SPACE SEE PLAN FOR DIMENSION T-SHAPED TURNING WHEELCHAIR CLEARANCE BUILDING PLAN SYMBOLS 101 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD & FACE OF FOUNDATION (U.O.N.). GRIDLINES ARE TO THE FACE OF STUD AT OUTSIDE EXTERIOR WALLS AND CENTERED BETWEEN UNITS AS DIMENSIONED ON PLANS.
ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.)
ALL DIMENSIONS AT
2.
3.
SIDE SHALL BE 6" MINIMUM U.O.N. FOR NOTES AND ADDITIONAL INFORMATION SEE INDIVIDUAL UNIT FLOOR PLANS. 7. PROTECT ALL PARTY WALL GYP. BOARD FROM RAIN AND MOISTURE DURING CONSTRUCTION. 8. BEFORE SEALING AIR SPACE BETWEEN PARTY WALLS-GYP. BOARD SHALL BE WITHOUT ANY MOISTURE 9. SEE FIRE ANNUNCIATOR DRAWINGS FOR ALARM LOCATION AND HOOKUP (DEFERRED SUBMITTAL) BLDG. PLAN GENERAL NOTES 10. FOR CODE ANALYSIS AND FIRE RATED WALL ASSEMBLIES REFER TO G SERIES SHEETS AND ENLARGED FLOOR PLAN A2 SERIES SHEETS. 11. STANDPIPE PROVIDED AT EACH STAIRWAY (DEFERRED SUBMITTAL). 12. SEE G2 SERIES SHEETS FOR ACCESSIBILITY REQUIREMENTS. 13. SEE ENLARGED PLANS ON A2 SERIES SHEETS FOR ADDITIONAL INFORMATION, TYP. 14. SEE A2.9 SERIES SHEETS FOR UNIT INFORMATION. 15. FOR EXTERIOR FINISH INFORMATION SEE A5 SERIES SHEETS 16. FOR UNIT PLAN REFLECTED CEILING PLAN INFORMATION SEE A2.9 SERIES SHEETS. 17. FOR BUILDING PLAN REFLECTED CEILING PLAN INFORMATION SEE A3 SERIES SHEETS. 18. SEE A7 SERIES SHEETS FOR DOOR AND WINDOW INFORMATION. 19. FOR LOCATIONS OF INDIVIDUALLY ENCASED POSTS AND BEAMS, SEE G2.1 SHEET SERIES. 1. PROTECTION OF JOINTS AND PENETRATIONS IN FIRE-RESISTIVE ASSEMBLIES SHALL NOT BE CONCEALED FROM VIEW UNTIL INSPECTED AND APPROVED. CBC SECTION 110.3.6. 2. FOR FIRE RATED WALL TYPE LOCATIONS, SEE CODE ANALYSIS AND G1 SHEETS. FOR DETAILS SEE BUILDING PLANS, A2 SERIES. 3. FIRE WALLS, FIRE BARRIERS, ETC.. SHALL BE LABELED IN AN ACCESSIBLE AREA AT 30'-0" O.C. STATING "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" FIRE PROTECTION NOTES 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND 4 4 D D 6 6 F F LAUNDRY ROOM ELEVATOR 1 2 A611 A611 7 A641 A642 4 4 D D 6 6 F F LAUNDRY ROOM ELEVATOR 1 17'-5" 4'-7 1/2" 12'-9" 1/2" 8'-1 1/2" 10'-7" 1/2" 18'-9" 7'-9 1/2" 2'-4 1/2" 3'-4" 1'-7" 2'-3 1/2" 1/2" 17'-5" 15'-7 1/2" 3'-1" 1/2" 18'-9" LAUNDRY ROOM ELEVATOR 1 A611 7 A641 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 4 : 3 6 P M A221.10 1648.001 AD/AO Checker ENLARGED PLANSLAUNDRY THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 1 ANNOTATION PLAN -LAUNDRY -5TH FLOOR 1/4" = 1'-0" 2 DIMENSION PLAN -LAUNDRY -5TH FLOOR 1/4" = 1'-0" 3 RCP -LAUNDRY -5TH FLOOR REVISIONS
60" 30"x48" 30"x60" REF. 30"x48" 30"x48" 30"x48"30"x48" 30"x48" 30"x48" 30"x60" 60" 60"x54" 60"x54" REF. REF. 1. CEILING HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF CEILING GYP. 2. EXTERIOR SOFFIT HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF EXTERIOR SOFFIT MATERIAL. 3. ALL EXTERIOR SOFFITS SHALL BE CP-1, U.O.N. 4. ALL DIMENSIONS TO F.O. STUD, (U.O.N.) 5. FOR CEILING DIFFUSERS, REGISTERS, AND VENTS TYPES, S.M.D. 6. FOR FURTHER INFORMATION REGARDING CEILING FIXTURES TYPES, S.E.D. 7. LOCATE LIGHTING FIXTURE @ CENTER OF CEILING U.O.N. 8. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS AND LOCATIONS SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE CENTER OF CEILING TILES, & SOFFITS TYP. U.O.N. INSTALLER SHALL COORDINATE INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS. 9. COORDINATE ALL FRAMING AT RECESSED FIXTURE LOCATIONS TO ACCOMMODATE FIXTURE LAYOUT PRIOR TO FRAMING. 10. SOFFIT WIDTH DIMENSIONS ARE FROM FACE OF STUD TO OUTER FINISH EDGE OF SOFFIT GYP. BOARD. 11. SOFFIT LOCATIONS VARY PER UNIT. S.M.D. AND SEE BUILDING PLANS FOR LOCATIONS. 12. STENCIL THE FOLLOWING TEXT: "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" IN CONCEALED SPACE ABOVE CEILINGS ON BOTH SIDES OF 1-HR RATED WALLS CEILING PLAN NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD, FACE OF FOUNDATION, (U.O.N.) 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE. (U.O.N.) 4. ALL ANGLED WALLS SHALL BE 45 DEGREES, U.O.N. 5. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" U.O.N. ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" U.O.N. 6. DIMENSIONS FOR TYPICAL UNIT FLOOR PLAN APPLY TO OTHER UNIT TYPES EXCEPT WHERE INDICATED ON VARIATION UNIT PLANS, VARIATION UNIT PLANS INDICATE MODIFICATIONS TO/FROM TYPICAL UNIT PLAN. 7. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2X6 STUDS, U.O.N., S.S.D. 8. ALL INTERIOR WALLS SHALL BE CONSTRUCTED OF 2X4 STUDS, U.O.N., S.S.D. 9. WINDOW HEAD HEIGHTS: 8'-2", U.O.N. 10. ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL PER CBC 2406.3. 11. ALL COUNTERS, TUB DECKS, & WALLS AT TUBS & SHOWERS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACES. FOR SHOWERS TO A HEIGHT OF +70" MIN. ABOVE DRAIN INLET PER CBC 1210.3. 12. VERIFY APPLIANCE DIMENSIONS PRIOR TO CABINET FABRICATION 13. FOR TYP. FIRE RATED ASSEMBLY DETAILS SEE G2 SHEETS 14. FOR TYP. FIRE RATED PENETRATION DETAILS SEE G2 SHEETS 15. FOR ACCESSIBILITY DETAILS AND NOTES SEE G3 SHEETS 16. FOR DIMENSIONS TO WINDOW AND DOOR OPENINGS REFER TO BUILDING PLAN SHEETS, A2 SERIES 17. SEE A7.3.1 FOR UNIT FINISH SCHEDULE 18. FOR INTERIOR UNIT DOORS, REFERENCE DOOR SCHEDULE -UNITS, A7.1 SERIES SHEETS. 19. FOR ENTRY DOORS SEE FLOOR PLANS ON A2.1 SERIES SHEETS AND DOOR SCHEDULE -BUILDING, A7.1 SERIES SHEETS. 20. ALL INTERIOR WALLS AT PODIUM ARE TO BE 2X4 MTL. STUD. ALL INTERIOR WALLS ABOVE PODIUM TO BE 2X4 WD. STUD U.N.O. SEE G3.1.1. 21. SEE BUILDING PLANS FOR INTERIOR WALL, PARTY WALL, OR CORRIDOR WALL INFORMATION AND DIMENSIONS. A2.1 SERIES SHEETS 22. 11B MOBILITY AND COMMUNICATION UNITS TO COMPLY WITH CBC 11B-809. SEE G4.2 SERIES CODE COMPLIANCE SHEETS FOR DETAILS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL COMMUNICATION FEATURES UNIT PLAN NOTES 0 W C WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL X/XX STRUCTURAL COLUMNS, S.S.D. 5'-0" DIA. TURNING SPACE PER CBC 11B-304.3.1 30" X 48" CLEAR FLOOR SPACE PER CBC 11B-305.3. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER 1 SHELF & POLE, SEE DETAIL 30"x60" TUB/SHOWER W/ SURROUND ON 3 WALLS TO +6'-8". SHOWER HEAD AT +78" & PER CPC 402.1.1 SEE INTERIOR ELEVATIONS AND S.P.D. FOR FINISH LAVATORY W/ FAUCET S.P.D. KITCHEN SINK W/ GARBAGE DISPOSAL & FAUCET, S.P.D. WATER CLOSET S.P.D. DISHWASHER W/ DRAIN TO GARBAGE DISPOSAL DRYER PROVIDE SMOOTH METAL VENT TO EXTERIOR FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR STACKED WASHER & DRYER-PROVIDE HOT & COLD WATER SUPPLY& WASTE SUPPLY & WASTE LINE FOR WASHER. PROVIDE SMOOTH METAL VENT TO EXTERIOR FOR DRYER. PROVIDE GSM W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D., S.M.D. 24" TOWEL BAR AT +40" HT. MAXIMUM TOILET PAPER HOLDER AT +24" HT. WASHER-PROVIDE HOT & COLD WATER SUPPLY & WASTE LINE. W/PAN W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D. FLOOR TYPE TRANSITION, SEE A7.3 FE 101 30" X 60" CLEAR FLOOR SPACE PER CBC 11B-607.2. RECESSED MEDICINE CABINET W/ BTM USABLE SHELF AT +44" HT. MAXIMUM PER CBC 11B-603.4. SLIDE-IN LINEN CABINET ELECTRICAL PANEL, S.E.D. 42" SIDE AND 36" REAR GRAB BARS RANGE HOOD UNIT PLAN SYMBOLS 101 A xxx-xx 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ALIGN INTERIOR FINISH MATERIAL, SEE A7.3 SERIES LIGHT FIXTURES (S.E.D.) MECH. REGISTERS (S.M.D.) GYP BOARD, PAINTED TRANSFER GRILLES RANGE HOOD REFLECTED CEILING SYMBOLS MTL-01 GRID GRID KITCHEN BATH 1 BED 1 LIVING PANTRY CLOSET COAT ENTRY W 6 W 6 W 4 1 0 W W 6 1A-01 1A-04 1A-05 1A-07 1A-08 GRID GRID 11'-5 1/2" 1'-5" 11'-5" 8'-3" 2'-3 1/2" 11'-2" 22'-3 1/2" 1/2" 2'-1" 5'-7" 5'-6 1/2" 8'-7 1/2" 2'-3 1/2" 11'-3 1/2" 7'-8" 14'-2" 13'-5 1/2" 18" MIN. 3'-9" 30" MIN. ( 2 5 M N ) 29 5 8 3 0 C L R 30" CLR. M N C L R 29 KITCHEN BATH 1 BED 1 LIVING PANTRY CLOSET COAT ENTRY 97 33 1 2 32 1 2 22'-4" 5 1/2" 21'-10" 1/2" GRID GRID KITCHEN BATH 1 BED 1 LIVING PANTRY CLOSET COAT ENTRY 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 4 : 4 9 P M A271.A 1648.001 AD/AO Checker UNIT PLANS - 1A THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/4" = 1'-0" 1 UNIT 1A -11B ANNOTATION 1/4" = 1'-0" 2 UNIT 1A -11B DIMENSION 1/4" = 1'-0" 3 UNIT 1A -11B RCP KEYNOTE LEGEND Key Value Keynote Text REVISIONS
60" 30"x48" 30"x60" REF. 30"x48" 30"x48" 30"x48" 30"x48" 30"x48" 54" 44" REF. REF. 1. CEILING HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF CEILING GYP. 2. EXTERIOR SOFFIT HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF EXTERIOR SOFFIT MATERIAL. 3. ALL EXTERIOR SOFFITS SHALL BE CP-1, U.O.N. 4. ALL DIMENSIONS TO F.O. STUD, (U.O.N.) 5. FOR CEILING DIFFUSERS, REGISTERS, AND VENTS TYPES, S.M.D. 6. FOR FURTHER INFORMATION REGARDING CEILING FIXTURES TYPES, S.E.D. 7. LOCATE LIGHTING FIXTURE @ CENTER OF CEILING U.O.N. 8. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS AND LOCATIONS SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE CENTER OF CEILING TILES, & SOFFITS TYP. U.O.N. INSTALLER SHALL COORDINATE INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS. 9. COORDINATE ALL FRAMING AT RECESSED FIXTURE LOCATIONS TO ACCOMMODATE FIXTURE LAYOUT PRIOR TO FRAMING. 10. SOFFIT WIDTH DIMENSIONS ARE FROM FACE OF STUD TO OUTER FINISH EDGE OF SOFFIT GYP. BOARD. 11. SOFFIT LOCATIONS VARY PER UNIT. S.M.D. AND SEE BUILDING PLANS FOR LOCATIONS. 12. STENCIL THE FOLLOWING TEXT: "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" IN CONCEALED SPACE ABOVE CEILINGS ON BOTH SIDES OF 1-HR RATED WALLS CEILING PLAN NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD, FACE OF FOUNDATION, (U.O.N.) 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE. (U.O.N.) 4. ALL ANGLED WALLS SHALL BE 45 DEGREES, U.O.N. 5. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" U.O.N. ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" U.O.N. 6. DIMENSIONS FOR TYPICAL UNIT FLOOR PLAN APPLY TO OTHER UNIT TYPES EXCEPT WHERE INDICATED ON VARIATION UNIT PLANS, VARIATION UNIT PLANS INDICATE MODIFICATIONS TO/FROM TYPICAL UNIT PLAN. 7. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2X6 STUDS, U.O.N., S.S.D. 8. ALL INTERIOR WALLS SHALL BE CONSTRUCTED OF 2X4 STUDS, U.O.N., S.S.D. 9. WINDOW HEAD HEIGHTS: 8'-2", U.O.N. 10. ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL PER CBC 2406.3. 11. ALL COUNTERS, TUB DECKS, & WALLS AT TUBS & SHOWERS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACES. FOR SHOWERS TO A HEIGHT OF +70" MIN. ABOVE DRAIN INLET PER CBC 1210.3. 12. VERIFY APPLIANCE DIMENSIONS PRIOR TO CABINET FABRICATION 13. FOR TYP. FIRE RATED ASSEMBLY DETAILS SEE G2 SHEETS 14. FOR TYP. FIRE RATED PENETRATION DETAILS SEE G2 SHEETS 15. FOR ACCESSIBILITY DETAILS AND NOTES SEE G3 SHEETS 16. FOR DIMENSIONS TO WINDOW AND DOOR OPENINGS REFER TO BUILDING PLAN SHEETS, A2 SERIES 17. SEE A7.3.1 FOR UNIT FINISH SCHEDULE 18. FOR INTERIOR UNIT DOORS, REFERENCE DOOR SCHEDULE -UNITS, A7.1 SERIES SHEETS. 19. FOR ENTRY DOORS SEE FLOOR PLANS ON A2.1 SERIES SHEETS AND DOOR SCHEDULE -BUILDING, A7.1 SERIES SHEETS. 20. ALL INTERIOR WALLS AT PODIUM ARE TO BE 2X4 MTL. STUD. ALL INTERIOR WALLS ABOVE PODIUM TO BE 2X4 WD. STUD U.N.O. SEE G3.1.1. 21. SEE BUILDING PLANS FOR INTERIOR WALL, PARTY WALL, OR CORRIDOR WALL INFORMATION AND DIMENSIONS. A2.1 SERIES SHEETS 22. 11B MOBILITY AND COMMUNICATION UNITS TO COMPLY WITH CBC 11B-809. SEE G4.2 SERIES CODE COMPLIANCE SHEETS FOR DETAILS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL COMMUNICATION FEATURES UNIT PLAN NOTES 0 W C WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL X/XX STRUCTURAL COLUMNS, S.S.D. 5'-0" DIA. TURNING SPACE PER CBC 11B-304.3.1 30" X 48" CLEAR FLOOR SPACE PER CBC 11B-305.3. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER 1 SHELF & POLE, SEE DETAIL 30"x60" TUB/SHOWER W/ SURROUND ON 3 WALLS TO +6'-8". SHOWER HEAD AT +78" & PER CPC 402.1.1 SEE INTERIOR ELEVATIONS AND S.P.D. FOR FINISH LAVATORY W/ FAUCET S.P.D. KITCHEN SINK W/ GARBAGE DISPOSAL & FAUCET, S.P.D. WATER CLOSET S.P.D. DISHWASHER W/ DRAIN TO GARBAGE DISPOSAL DRYER PROVIDE SMOOTH METAL VENT TO EXTERIOR FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR STACKED WASHER & DRYER-PROVIDE HOT & COLD WATER SUPPLY& WASTE SUPPLY & WASTE LINE FOR WASHER. PROVIDE SMOOTH METAL VENT TO EXTERIOR FOR DRYER. PROVIDE GSM W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D., S.M.D. 24" TOWEL BAR AT +40" HT. MAXIMUM TOILET PAPER HOLDER AT +24" HT. WASHER-PROVIDE HOT & COLD WATER SUPPLY & WASTE LINE. W/PAN W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D. FLOOR TYPE TRANSITION, SEE A7.3 FE 101 30" X 60" CLEAR FLOOR SPACE PER CBC 11B-607.2. RECESSED MEDICINE CABINET W/ BTM USABLE SHELF AT +44" HT. MAXIMUM PER CBC 11B-603.4. SLIDE-IN LINEN CABINET ELECTRICAL PANEL, S.E.D. 42" SIDE AND 36" REAR GRAB BARS RANGE HOOD UNIT PLAN SYMBOLS 101 A xxx-xx 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ALIGN INTERIOR FINISH MATERIAL, SEE A7.3 SERIES LIGHT FIXTURES (S.E.D.) MECH. REGISTERS (S.M.D.) GYP BOARD, PAINTED TRANSFER GRILLES RANGE HOOD REFLECTED CEILING SYMBOLS MTL-01 GRID GRID ENTRY KITCHEN LIVING BATH 1 PANTRY CLOSET BED 1 ELEVATOR 2 1B-01 1B-02 1B-04 1B-03 W 4 1 W 6 0 W W 6 GRID GRID F O R A L T E R N A T E S E E B U L D N G P L A N S 27 84 15'-7 1/2" 10'-10" 61 0 85 1 2 81 1 2 31 1 2 2 66 1 2 1 8 M N 39 2 5 M N 25 7 8 3 0 M N 30" CLR. 3 0 C L R 1 13 1 53 1 / 2 3'-1 1/2" 5'-1 1/2" 20 46 1 2 48 1 / 2 3'-0 1/2" ENTRY KITCHEN LIVING BATH 1 PANTRY CLOSET BED 1 ELEVATOR 2 27'-3" 2 50 MIN. CLR. 2'-9" 17'-0" 10'-8" 1/2" 27'-8 1/2" 8'-3" 8'-1 1/2" 10'-10" 1/2" 4'-6" GRID GRID ENTRY KITCHEN LIVING BATH 1 PANTRY CLOSET BED 1 ELEVATOR 2 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 4 : 5 7 P M A271.B 1648.001 AD/AO Checker UNIT PLANS - 1B THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/4" = 1'-0" 1 UNIT 1B -11A ANNOTATION 1/4" = 1'-0" 2 UNIT 1B -11A DIMENSION 1/4" = 1'-0" 3 UNIT 1B -RCP KEYNOTE LEGEND Key Value Keynote Text REVISIONS
60" 30"x48" 30"x60" REF. 30"x48" 30"x48" 30"x48"30"x48" 30"x48" 30"x48"30"x48" 30"x48" 54" 44" REF. REF. REF. REF. 30"x48" 30"x48" 30"x48"30"x48" 30"x48" 60"x54" 60"x54" 30"x48" 30"x60" 30"x48" 60"x60" 60"x54" 60" 60"x54" 1. CEILING HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF CEILING GYP. 2. EXTERIOR SOFFIT HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF EXTERIOR SOFFIT MATERIAL. 3. ALL EXTERIOR SOFFITS SHALL BE CP-1, U.O.N. 4. ALL DIMENSIONS TO F.O. STUD, (U.O.N.) 5. FOR CEILING DIFFUSERS, REGISTERS, AND VENTS TYPES, S.M.D. 6. FOR FURTHER INFORMATION REGARDING CEILING FIXTURES TYPES, S.E.D. 7. LOCATE LIGHTING FIXTURE @ CENTER OF CEILING U.O.N. 8. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS AND LOCATIONS SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE CENTER OF CEILING TILES, & SOFFITS TYP. U.O.N. INSTALLER SHALL COORDINATE INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS. 9. COORDINATE ALL FRAMING AT RECESSED FIXTURE LOCATIONS TO ACCOMMODATE FIXTURE LAYOUT PRIOR TO FRAMING. 10. SOFFIT WIDTH DIMENSIONS ARE FROM FACE OF STUD TO OUTER FINISH EDGE OF SOFFIT GYP. BOARD. 11. SOFFIT LOCATIONS VARY PER UNIT. S.M.D. AND SEE BUILDING PLANS FOR LOCATIONS. 12. STENCIL THE FOLLOWING TEXT: "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" IN CONCEALED SPACE ABOVE CEILINGS ON BOTH SIDES OF 1-HR RATED WALLS CEILING PLAN NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD, FACE OF FOUNDATION, (U.O.N.) 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE. (U.O.N.) 4. ALL ANGLED WALLS SHALL BE 45 DEGREES, U.O.N. 5. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" U.O.N. ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" U.O.N. 6. DIMENSIONS FOR TYPICAL UNIT FLOOR PLAN APPLY TO OTHER UNIT TYPES EXCEPT WHERE INDICATED ON VARIATION UNIT PLANS, VARIATION UNIT PLANS INDICATE MODIFICATIONS TO/FROM TYPICAL UNIT PLAN. 7. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2X6 STUDS, U.O.N., S.S.D. 8. ALL INTERIOR WALLS SHALL BE CONSTRUCTED OF 2X4 STUDS, U.O.N., S.S.D. 9. WINDOW HEAD HEIGHTS: 8'-2", U.O.N. 10. ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL PER CBC 2406.3. 11. ALL COUNTERS, TUB DECKS, & WALLS AT TUBS & SHOWERS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACES. FOR SHOWERS TO A HEIGHT OF +70" MIN. ABOVE DRAIN INLET PER CBC 1210.3. 12. VERIFY APPLIANCE DIMENSIONS PRIOR TO CABINET FABRICATION 13. FOR TYP. FIRE RATED ASSEMBLY DETAILS SEE G2 SHEETS 14. FOR TYP. FIRE RATED PENETRATION DETAILS SEE G2 SHEETS 15. FOR ACCESSIBILITY DETAILS AND NOTES SEE G3 SHEETS 16. FOR DIMENSIONS TO WINDOW AND DOOR OPENINGS REFER TO BUILDING PLAN SHEETS, A2 SERIES 17. SEE A7.3.1 FOR UNIT FINISH SCHEDULE 18. FOR INTERIOR UNIT DOORS, REFERENCE DOOR SCHEDULE -UNITS, A7.1 SERIES SHEETS. 19. FOR ENTRY DOORS SEE FLOOR PLANS ON A2.1 SERIES SHEETS AND DOOR SCHEDULE -BUILDING, A7.1 SERIES SHEETS. 20. ALL INTERIOR WALLS AT PODIUM ARE TO BE 2X4 MTL. STUD. ALL INTERIOR WALLS ABOVE PODIUM TO BE 2X4 WD. STUD U.N.O. SEE G3.1.1. 21. SEE BUILDING PLANS FOR INTERIOR WALL, PARTY WALL, OR CORRIDOR WALL INFORMATION AND DIMENSIONS. A2.1 SERIES SHEETS 22. 11B MOBILITY AND COMMUNICATION UNITS TO COMPLY WITH CBC 11B-809. SEE G4.2 SERIES CODE COMPLIANCE SHEETS FOR DETAILS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL COMMUNICATION FEATURES UNIT PLAN NOTES 0 W C WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL X/XX STRUCTURAL COLUMNS, S.S.D. 5'-0" DIA. TURNING SPACE PER CBC 11B-304.3.1 30" X 48" CLEAR FLOOR SPACE PER CBC 11B-305.3. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER 1 SHELF & POLE, SEE DETAIL 30"x60" TUB/SHOWER W/ SURROUND ON 3 WALLS TO +6'-8". SHOWER HEAD AT +78" & PER CPC 402.1.1 SEE INTERIOR ELEVATIONS AND S.P.D. FOR FINISH LAVATORY W/ FAUCET S.P.D. KITCHEN SINK W/ GARBAGE DISPOSAL & FAUCET, S.P.D. WATER CLOSET S.P.D. DISHWASHER W/ DRAIN TO GARBAGE DISPOSAL DRYER PROVIDE SMOOTH METAL VENT TO EXTERIOR FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR STACKED WASHER & DRYER-PROVIDE HOT & COLD WATER SUPPLY& WASTE SUPPLY & WASTE LINE FOR WASHER. PROVIDE SMOOTH METAL VENT TO EXTERIOR FOR DRYER. PROVIDE GSM W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D., S.M.D. 24" TOWEL BAR AT +40" HT. MAXIMUM TOILET PAPER HOLDER AT +24" HT. WASHER-PROVIDE HOT & COLD WATER SUPPLY & WASTE LINE. W/PAN W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D. FLOOR TYPE TRANSITION, SEE A7.3 FE 101 30" X 60" CLEAR FLOOR SPACE PER CBC 11B-607.2. RECESSED MEDICINE CABINET W/ BTM USABLE SHELF AT +44" HT. MAXIMUM PER CBC 11B-603.4. SLIDE-IN LINEN CABINET ELECTRICAL PANEL, S.E.D. 42" SIDE AND 36" REAR GRAB BARS RANGE HOOD UNIT PLAN SYMBOLS 101 A xxx-xx 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ALIGN INTERIOR FINISH MATERIAL, SEE A7.3 SERIES LIGHT FIXTURES (S.E.D.) MECH. REGISTERS (S.M.D.) GYP BOARD, PAINTED TRANSFER GRILLES RANGE HOOD REFLECTED CEILING SYMBOLS MTL-01 GRID GRID 2A-06 2A-04 2A-02 2A-03 2A-05 2A-01 KITCHEN LIVING BED 1 BED 2 BATH 1 W.I.C. COAT CLOSET ? ? ? ? ? ? W 6 0 W 0 W PANTRY GRID GRID 2 30 11'-4" 10'-9" 10'-11 1/2" 1/2" 33'-1" 1 14 1 / 2 60 1 2 55 22 1 75 77 2 50 3'-2" 7'-8" 2'-5 1/2" 19'-3 1/2" 10'-10" 21'-9" 1/2" 32'-7" 5 1/2" 5'-7" 5'-1 1/2" 5'-5" 5'-2" 27 1 04 KITCHEN LIVING BED 1 BED 2 BATH 1 W.I.C. COAT CLOSET 18" MIN. 3'-9" (25" MIN.) 2'-6 3/8" 30" MIN. M I N C L R 39 PANTRY 33'-1" GRID GRID KITCHEN LIVING BED 1 BED 2 BATH 1 W.I.C. COAT CLOSET 26 1 2 57 81 1 2 55 1 2 C L R 4 7 M N PANTRY 18'-7 5/8" 2'-3 1/2" 7'-8" 3'-0 1/2" 20'-11 1/8" 10'-8 1/2" 18" MIN. 3'-9" (25" MIN.) 2'-6 1/8" 30" CLR. 31'-7 5/8" KITCHEN LIVING BED 1 BED 2 W.I.C. BATH 1 COAT CLOSET 13'-1 1/8" 5'-6 1/2" PANTRY 2A-04 2A-02 2A-03 2A-07 2A-06 KITCHEN LIVING BED 1 BED 2 W.I.C. BATH 1 COAT CLOSET 2A-05 0 W 6 W W W 6 W 6 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 5 : 1 7 P M A272.A 1648.001 AD/AO Checker UNIT PLANS - 2A THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/4" = 1'-0" 1 UNIT 2A -ANNOTATION 1/4" = 1'-0" 2 UNIT 2A -DIMENSION 1/4" = 1'-0" 3 UNIT 2A -RCP KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 4 11B KITCHEN & BATHROOM -DIMENSION 1/4" = 1'-0" 5 11B KITCHEN & BATHROOM -ANNOTATION REVISIONS
60" 30"x48" 30"x60" REF. 30"x48" 30"x48"30"x48" 30"x48" 30"x48" 30"x48" 30"x48" 54" 44" REF. REF. 1. CEILING HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF CEILING GYP. 2. EXTERIOR SOFFIT HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF EXTERIOR SOFFIT MATERIAL. 3. ALL EXTERIOR SOFFITS SHALL BE CP-1, U.O.N. 4. ALL DIMENSIONS TO F.O. STUD, (U.O.N.) 5. FOR CEILING DIFFUSERS, REGISTERS, AND VENTS TYPES, S.M.D. 6. FOR FURTHER INFORMATION REGARDING CEILING FIXTURES TYPES, S.E.D. 7. LOCATE LIGHTING FIXTURE @ CENTER OF CEILING U.O.N. 8. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS AND LOCATIONS SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE CENTER OF CEILING TILES, & SOFFITS TYP. U.O.N. INSTALLER SHALL COORDINATE INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS. 9. COORDINATE ALL FRAMING AT RECESSED FIXTURE LOCATIONS TO ACCOMMODATE FIXTURE LAYOUT PRIOR TO FRAMING. 10. SOFFIT WIDTH DIMENSIONS ARE FROM FACE OF STUD TO OUTER FINISH EDGE OF SOFFIT GYP. BOARD. 11. SOFFIT LOCATIONS VARY PER UNIT. S.M.D. AND SEE BUILDING PLANS FOR LOCATIONS. 12. STENCIL THE FOLLOWING TEXT: "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" IN CONCEALED SPACE ABOVE CEILINGS ON BOTH SIDES OF 1-HR RATED WALLS CEILING PLAN NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD, FACE OF FOUNDATION, (U.O.N.) 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE. (U.O.N.) 4. ALL ANGLED WALLS SHALL BE 45 DEGREES, U.O.N. 5. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" U.O.N. ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" U.O.N. 6. DIMENSIONS FOR TYPICAL UNIT FLOOR PLAN APPLY TO OTHER UNIT TYPES EXCEPT WHERE INDICATED ON VARIATION UNIT PLANS, VARIATION UNIT PLANS INDICATE MODIFICATIONS TO/FROM TYPICAL UNIT PLAN. 7. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2X6 STUDS, U.O.N., S.S.D. 8. ALL INTERIOR WALLS SHALL BE CONSTRUCTED OF 2X4 STUDS, U.O.N., S.S.D. 9. WINDOW HEAD HEIGHTS: 8'-2", U.O.N. 10. ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL PER CBC 2406.3. 11. ALL COUNTERS, TUB DECKS, & WALLS AT TUBS & SHOWERS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACES. FOR SHOWERS TO A HEIGHT OF +70" MIN. ABOVE DRAIN INLET PER CBC 1210.3. 12. VERIFY APPLIANCE DIMENSIONS PRIOR TO CABINET FABRICATION 13. FOR TYP. FIRE RATED ASSEMBLY DETAILS SEE G2 SHEETS 14. FOR TYP. FIRE RATED PENETRATION DETAILS SEE G2 SHEETS 15. FOR ACCESSIBILITY DETAILS AND NOTES SEE G3 SHEETS 16. FOR DIMENSIONS TO WINDOW AND DOOR OPENINGS REFER TO BUILDING PLAN SHEETS, A2 SERIES 17. SEE A7.3.1 FOR UNIT FINISH SCHEDULE 18. FOR INTERIOR UNIT DOORS, REFERENCE DOOR SCHEDULE -UNITS, A7.1 SERIES SHEETS. 19. FOR ENTRY DOORS SEE FLOOR PLANS ON A2.1 SERIES SHEETS AND DOOR SCHEDULE -BUILDING, A7.1 SERIES SHEETS. 20. ALL INTERIOR WALLS AT PODIUM ARE TO BE 2X4 MTL. STUD. ALL INTERIOR WALLS ABOVE PODIUM TO BE 2X4 WD. STUD U.N.O. SEE G3.1.1. 21. SEE BUILDING PLANS FOR INTERIOR WALL, PARTY WALL, OR CORRIDOR WALL INFORMATION AND DIMENSIONS. A2.1 SERIES SHEETS 22. 11B MOBILITY AND COMMUNICATION UNITS TO COMPLY WITH CBC 11B-809. SEE G4.2 SERIES CODE COMPLIANCE SHEETS FOR DETAILS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL COMMUNICATION FEATURES UNIT PLAN NOTES 0 W C WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL X/XX STRUCTURAL COLUMNS, S.S.D. 5'-0" DIA. TURNING SPACE PER CBC 11B-304.3.1 30" X 48" CLEAR FLOOR SPACE PER CBC 11B-305.3. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER 1 SHELF & POLE, SEE DETAIL 30"x60" TUB/SHOWER W/ SURROUND ON 3 WALLS TO +6'-8". SHOWER HEAD AT +78" & PER CPC 402.1.1 SEE INTERIOR ELEVATIONS AND S.P.D. FOR FINISH LAVATORY W/ FAUCET S.P.D. KITCHEN SINK W/ GARBAGE DISPOSAL & FAUCET, S.P.D. WATER CLOSET S.P.D. DISHWASHER W/ DRAIN TO GARBAGE DISPOSAL DRYER PROVIDE SMOOTH METAL VENT TO EXTERIOR FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR STACKED WASHER & DRYER-PROVIDE HOT & COLD WATER SUPPLY& WASTE SUPPLY & WASTE LINE FOR WASHER. PROVIDE SMOOTH METAL VENT TO EXTERIOR FOR DRYER. PROVIDE GSM W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D., S.M.D. 24" TOWEL BAR AT +40" HT. MAXIMUM TOILET PAPER HOLDER AT +24" HT. WASHER-PROVIDE HOT & COLD WATER SUPPLY & WASTE LINE. W/PAN W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D. FLOOR TYPE TRANSITION, SEE A7.3 FE 101 30" X 60" CLEAR FLOOR SPACE PER CBC 11B-607.2. RECESSED MEDICINE CABINET W/ BTM USABLE SHELF AT +44" HT. MAXIMUM PER CBC 11B-603.4. SLIDE-IN LINEN CABINET ELECTRICAL PANEL, S.E.D. 42" SIDE AND 36" REAR GRAB BARS RANGE HOOD UNIT PLAN SYMBOLS 101 A xxx-xx 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ALIGN INTERIOR FINISH MATERIAL, SEE A7.3 SERIES LIGHT FIXTURES (S.E.D.) MECH. REGISTERS (S.M.D.) GYP BOARD, PAINTED TRANSFER GRILLES RANGE HOOD REFLECTED CEILING SYMBOLS MTL-01 GRID GRID 2B-01 2B-03 2B-02 2B-06 2B-04 ENTRY COAT BATH 1 KITCHEN LIVING CLOSET BED 1 CLOSET BED 2 2B-05 W 6 W 6 W 6 0 W PANTRY GRID GRID GRID 11'-8 1/2" 2'-3 1/2" 14'-0" 14'-0 1/2" 6" 7'-7" 36'-1 1/2" 1/2" 7'-7 1/2" 1 09 1 4 23 1 / 2 1 11 1 1 4 2 50 11'-3" 16'-6 1/2" 5'-6 1/2" 2'-3 1/2" 1/2" 27'-9 1/2" 7'-10" 35'-7 1/2" 30" CLR. 30" CLR. M N C L R 29 18" MIN. 1 8 M N 39 2 5 M N 21 0 7 / 8 3 0 C L R 1 2 85 21 0 1 / 2 63 1 14 75 2 50 86 85 61 0 1 / 2 6'-9" 3'-9" ENTRY COAT BATH 1 KITCHEN LIVING CLOSET BED 1 CLOSET BED 2 PANTRY GRID GRID GRID ENTRY COAT BATH 1 KITCHEN LIVING CLOSET BED 1 CLOSET BED 2 BED 2 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 5 : 3 0 P M A272.B 1648.001 AD/AO Checker UNIT PLANS - 2B THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/4" = 1'-0" 1 UNIT 2B -ANNOTATION 1/4" = 1'-0" 2 UNIT 2B -DIMENSION 1/4" = 1'-0" 3 UNIT 2B -RCP KEYNOTE LEGEND Key Value Keynote Text REVISIONS
60" 30"x48" 30"x60" REF. 60" 30"x48" 3 x 8 0 8 3 0 4 60" REF. REF. REF. 54" 44" 30"x48" 30"x48" 30"x48" 60"x60" 30"x48" 30"x48" 60" 60" 60"x60" REF. 1. CEILING HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF CEILING GYP. 2. EXTERIOR SOFFIT HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF EXTERIOR SOFFIT MATERIAL. 3. ALL EXTERIOR SOFFITS SHALL BE CP-1, U.O.N. 4. ALL DIMENSIONS TO F.O. STUD, (U.O.N.) 5. FOR CEILING DIFFUSERS, REGISTERS, AND VENTS TYPES, S.M.D. 6. FOR FURTHER INFORMATION REGARDING CEILING FIXTURES TYPES, S.E.D. 7. LOCATE LIGHTING FIXTURE @ CENTER OF CEILING U.O.N. 8. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS AND LOCATIONS SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE CENTER OF CEILING TILES, & SOFFITS TYP. U.O.N. INSTALLER SHALL COORDINATE INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS. 9. COORDINATE ALL FRAMING AT RECESSED FIXTURE LOCATIONS TO ACCOMMODATE FIXTURE LAYOUT PRIOR TO FRAMING. 10. SOFFIT WIDTH DIMENSIONS ARE FROM FACE OF STUD TO OUTER FINISH EDGE OF SOFFIT GYP. BOARD. 11. SOFFIT LOCATIONS VARY PER UNIT. S.M.D. AND SEE BUILDING PLANS FOR LOCATIONS. 12. STENCIL THE FOLLOWING TEXT: "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" IN CONCEALED SPACE ABOVE CEILINGS ON BOTH SIDES OF 1-HR RATED WALLS CEILING PLAN NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD, FACE OF FOUNDATION, (U.O.N.) 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE. (U.O.N.) 4. ALL ANGLED WALLS SHALL BE 45 DEGREES, U.O.N. 5. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" U.O.N. ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" U.O.N. 6. DIMENSIONS FOR TYPICAL UNIT FLOOR PLAN APPLY TO OTHER UNIT TYPES EXCEPT WHERE INDICATED ON VARIATION UNIT PLANS, VARIATION UNIT PLANS INDICATE MODIFICATIONS TO/FROM TYPICAL UNIT PLAN. 7. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2X6 STUDS, U.O.N., S.S.D. 8. ALL INTERIOR WALLS SHALL BE CONSTRUCTED OF 2X4 STUDS, U.O.N., S.S.D. 9. WINDOW HEAD HEIGHTS: 8'-2", U.O.N. 10. ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL PER CBC 2406.3. 11. ALL COUNTERS, TUB DECKS, & WALLS AT TUBS & SHOWERS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACES. FOR SHOWERS TO A HEIGHT OF +70" MIN. ABOVE DRAIN INLET PER CBC 1210.3. 12. VERIFY APPLIANCE DIMENSIONS PRIOR TO CABINET FABRICATION 13. FOR TYP. FIRE RATED ASSEMBLY DETAILS SEE G2 SHEETS 14. FOR TYP. FIRE RATED PENETRATION DETAILS SEE G2 SHEETS 15. FOR ACCESSIBILITY DETAILS AND NOTES SEE G3 SHEETS 16. FOR DIMENSIONS TO WINDOW AND DOOR OPENINGS REFER TO BUILDING PLAN SHEETS, A2 SERIES 17. SEE A7.3.1 FOR UNIT FINISH SCHEDULE 18. FOR INTERIOR UNIT DOORS, REFERENCE DOOR SCHEDULE -UNITS, A7.1 SERIES SHEETS. 19. FOR ENTRY DOORS SEE FLOOR PLANS ON A2.1 SERIES SHEETS AND DOOR SCHEDULE -BUILDING, A7.1 SERIES SHEETS. 20. ALL INTERIOR WALLS AT PODIUM ARE TO BE 2X4 MTL. STUD. ALL INTERIOR WALLS ABOVE PODIUM TO BE 2X4 WD. STUD U.N.O. SEE G3.1.1. 21. SEE BUILDING PLANS FOR INTERIOR WALL, PARTY WALL, OR CORRIDOR WALL INFORMATION AND DIMENSIONS. A2.1 SERIES SHEETS 22. 11B MOBILITY AND COMMUNICATION UNITS TO COMPLY WITH CBC 11B-809. SEE G4.2 SERIES CODE COMPLIANCE SHEETS FOR DETAILS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL COMMUNICATION FEATURES UNIT PLAN NOTES 0 W C WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL X/XX STRUCTURAL COLUMNS, S.S.D. 5'-0" DIA. TURNING SPACE PER CBC 11B-304.3.1 30" X 48" CLEAR FLOOR SPACE PER CBC 11B-305.3. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER 1 SHELF & POLE, SEE DETAIL 30"x60" TUB/SHOWER W/ SURROUND ON 3 WALLS TO +6'-8". SHOWER HEAD AT +78" & PER CPC 402.1.1 SEE INTERIOR ELEVATIONS AND S.P.D. FOR FINISH LAVATORY W/ FAUCET S.P.D. KITCHEN SINK W/ GARBAGE DISPOSAL & FAUCET, S.P.D. WATER CLOSET S.P.D. DISHWASHER W/ DRAIN TO GARBAGE DISPOSAL DRYER PROVIDE SMOOTH METAL VENT TO EXTERIOR FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR STACKED WASHER & DRYER-PROVIDE HOT & COLD WATER SUPPLY& WASTE SUPPLY & WASTE LINE FOR WASHER. PROVIDE SMOOTH METAL VENT TO EXTERIOR FOR DRYER. PROVIDE GSM W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D., S.M.D. 24" TOWEL BAR AT +40" HT. MAXIMUM TOILET PAPER HOLDER AT +24" HT. WASHER-PROVIDE HOT & COLD WATER SUPPLY & WASTE LINE. W/PAN W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D. FLOOR TYPE TRANSITION, SEE A7.3 FE 101 30" X 60" CLEAR FLOOR SPACE PER CBC 11B-607.2. RECESSED MEDICINE CABINET W/ BTM USABLE SHELF AT +44" HT. MAXIMUM PER CBC 11B-603.4. SLIDE-IN LINEN CABINET ELECTRICAL PANEL, S.E.D. 42" SIDE AND 36" REAR GRAB BARS RANGE HOOD UNIT PLAN SYMBOLS 101 A xxx-xx 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ALIGN INTERIOR FINISH MATERIAL, SEE A7.3 SERIES LIGHT FIXTURES (S.E.D.) MECH. REGISTERS (S.M.D.) GYP BOARD, PAINTED TRANSFER GRILLES RANGE HOOD REFLECTED CEILING SYMBOLS MTL-01 3A-06 3A-05 3A-02 3A-03 3A-07 3A-01 3A-04 ENTRY CLOSET BATH 1 BATH 2 WIC BED 1 BED 2 CLOSET LIVING BED 3 CLOSET KITCHEN 3A-08 3A-09 W 6 W 0 W W W 1 0 W GRID GRID GRID GRID ENTRY CLOSET BATH 1 BATH 2 WIC BED 1 BED 2 CLOSET LIVING BED 3 CLOSET KITCHEN GRID GRID GRID GRID 44'-1" 1/2" 43'-7" 1/2" 3'-2 1/2" 7'-6" 7'-9 1/2" 2'-10" 10'-8 1/2" 10'-7 1/2" 2'-3 1/2" 5'-6 1/2" 14'-5" (25" MIN.) 2'-4 3/8" 18" MIN. 3'-9" (25" MIN.) 2'-2 5/8" 18" MIN. 3'-9" 1 21 1 1 2 23 1 2 99 2 50 10'-8 1/2" 10'-7 1/2" 11'-9" 10'-11" 1/2" 44'-0" 1/2" 1 13 1 / 2 58 57 25 1 2 2 50 PANTRY 44'-1" MIN. CLR. 2'-9" 30" CLR. 3 0 C L R 4 7 C L R F O R A L T E R N A T E S E E B U L D N G P L A N S GRID GRID GRID GRID 3A-05 3A-02 3A-03 3A-07 3A-01 3A-08 3A-09 3A-04 LIVING BED 3 UNIT 3A KITCHEN ENTRY BED 2 CLOSET BED 1 WIC BATH 2 BATH 1 CLOSET PANTRY W W 6 W 6 0 W 6 0 M 4 LIVING BED 3 UNIT 3A KITCHEN ENTRY CLOSET BED 1 WIC BATH 2 BATH 1 CLOSET PANTRY 2'-10" 7'-9 1/2" 7'-9 1/2" 2'-11" 19'-11 1/2" 2'-3 1/2" 10'-7 1/2" 10'-8 1/2" 18" MIN. 43'-7" 3'-9" (25" MIN.) 2'-4 3/8" 18" MIN. 3'-9" (25" MIN.) 2'-1 5/8" 26 81 55 C L R 4 7 M N 5'-3" 5'-2" 14'-5" 5'-6 1/2" 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 5 : 4 7 P M A273.A1 1648.001 AD/AO Checker UNIT PLANS - 3A THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/4" = 1'-0" 1 UNIT 3A -ANNOTATION 1/4" = 1'-0" 2 UNIT 3A -DIMENSION 1/4" = 1'-0" 3 UNIT 3A -RCP KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 4 11B KITCHEN & BATHROOM -ANNOTATION 1/4" = 1'-0" 5 11B KITCHEN & BATHROOM -DIMENSION REVISIONS
60" 30"x48" 30"x60" REF. 60" 60" 30"x48" 3 4 8 0 4 8 30"x48" 54" 44" REF. REF.REF. REF. 1. CEILING HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF CEILING GYP. 2. EXTERIOR SOFFIT HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF EXTERIOR SOFFIT MATERIAL. 3. ALL EXTERIOR SOFFITS SHALL BE CP-1, U.O.N. 4. ALL DIMENSIONS TO F.O. STUD, (U.O.N.) 5. FOR CEILING DIFFUSERS, REGISTERS, AND VENTS TYPES, S.M.D. 6. FOR FURTHER INFORMATION REGARDING CEILING FIXTURES TYPES, S.E.D. 7. LOCATE LIGHTING FIXTURE @ CENTER OF CEILING U.O.N. 8. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS AND LOCATIONS SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE CENTER OF CEILING TILES, & SOFFITS TYP. U.O.N. INSTALLER SHALL COORDINATE INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS. 9. COORDINATE ALL FRAMING AT RECESSED FIXTURE LOCATIONS TO ACCOMMODATE FIXTURE LAYOUT PRIOR TO FRAMING. 10. SOFFIT WIDTH DIMENSIONS ARE FROM FACE OF STUD TO OUTER FINISH EDGE OF SOFFIT GYP. BOARD. 11. SOFFIT LOCATIONS VARY PER UNIT. S.M.D. AND SEE BUILDING PLANS FOR LOCATIONS. 12. STENCIL THE FOLLOWING TEXT: "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" IN CONCEALED SPACE ABOVE CEILINGS ON BOTH SIDES OF 1-HR RATED WALLS CEILING PLAN NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD, FACE OF FOUNDATION, (U.O.N.) 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE. (U.O.N.) 4. ALL ANGLED WALLS SHALL BE 45 DEGREES, U.O.N. 5. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" U.O.N. ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" U.O.N. 6. DIMENSIONS FOR TYPICAL UNIT FLOOR PLAN APPLY TO OTHER UNIT TYPES EXCEPT WHERE INDICATED ON VARIATION UNIT PLANS, VARIATION UNIT PLANS INDICATE MODIFICATIONS TO/FROM TYPICAL UNIT PLAN. 7. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2X6 STUDS, U.O.N., S.S.D. 8. ALL INTERIOR WALLS SHALL BE CONSTRUCTED OF 2X4 STUDS, U.O.N., S.S.D. 9. WINDOW HEAD HEIGHTS: 8'-2", U.O.N. 10. ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL PER CBC 2406.3. 11. ALL COUNTERS, TUB DECKS, & WALLS AT TUBS & SHOWERS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACES. FOR SHOWERS TO A HEIGHT OF +70" MIN. ABOVE DRAIN INLET PER CBC 1210.3. 12. VERIFY APPLIANCE DIMENSIONS PRIOR TO CABINET FABRICATION 13. FOR TYP. FIRE RATED ASSEMBLY DETAILS SEE G2 SHEETS 14. FOR TYP. FIRE RATED PENETRATION DETAILS SEE G2 SHEETS 15. FOR ACCESSIBILITY DETAILS AND NOTES SEE G3 SHEETS 16. FOR DIMENSIONS TO WINDOW AND DOOR OPENINGS REFER TO BUILDING PLAN SHEETS, A2 SERIES 17. SEE A7.3.1 FOR UNIT FINISH SCHEDULE 18. FOR INTERIOR UNIT DOORS, REFERENCE DOOR SCHEDULE -UNITS, A7.1 SERIES SHEETS. 19. FOR ENTRY DOORS SEE FLOOR PLANS ON A2.1 SERIES SHEETS AND DOOR SCHEDULE -BUILDING, A7.1 SERIES SHEETS. 20. ALL INTERIOR WALLS AT PODIUM ARE TO BE 2X4 MTL. STUD. ALL INTERIOR WALLS ABOVE PODIUM TO BE 2X4 WD. STUD U.N.O. SEE G3.1.1. 21. SEE BUILDING PLANS FOR INTERIOR WALL, PARTY WALL, OR CORRIDOR WALL INFORMATION AND DIMENSIONS. A2.1 SERIES SHEETS 22. 11B MOBILITY AND COMMUNICATION UNITS TO COMPLY WITH CBC 11B-809. SEE G4.2 SERIES CODE COMPLIANCE SHEETS FOR DETAILS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL COMMUNICATION FEATURES UNIT PLAN NOTES 0 W C WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL X/XX STRUCTURAL COLUMNS, S.S.D. 5'-0" DIA. TURNING SPACE PER CBC 11B-304.3.1 30" X 48" CLEAR FLOOR SPACE PER CBC 11B-305.3. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER 1 SHELF & POLE, SEE DETAIL 30"x60" TUB/SHOWER W/ SURROUND ON 3 WALLS TO +6'-8". SHOWER HEAD AT +78" & PER CPC 402.1.1 SEE INTERIOR ELEVATIONS AND S.P.D. FOR FINISH LAVATORY W/ FAUCET S.P.D. KITCHEN SINK W/ GARBAGE DISPOSAL & FAUCET, S.P.D. WATER CLOSET S.P.D. DISHWASHER W/ DRAIN TO GARBAGE DISPOSAL DRYER PROVIDE SMOOTH METAL VENT TO EXTERIOR FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR STACKED WASHER & DRYER-PROVIDE HOT & COLD WATER SUPPLY& WASTE SUPPLY & WASTE LINE FOR WASHER. PROVIDE SMOOTH METAL VENT TO EXTERIOR FOR DRYER. PROVIDE GSM W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D., S.M.D. 24" TOWEL BAR AT +40" HT. MAXIMUM TOILET PAPER HOLDER AT +24" HT. WASHER-PROVIDE HOT & COLD WATER SUPPLY & WASTE LINE. W/PAN W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D. FLOOR TYPE TRANSITION, SEE A7.3 FE 101 30" X 60" CLEAR FLOOR SPACE PER CBC 11B-607.2. RECESSED MEDICINE CABINET W/ BTM USABLE SHELF AT +44" HT. MAXIMUM PER CBC 11B-603.4. SLIDE-IN LINEN CABINET ELECTRICAL PANEL, S.E.D. 42" SIDE AND 36" REAR GRAB BARS RANGE HOOD UNIT PLAN SYMBOLS 101 A xxx-xx 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ALIGN INTERIOR FINISH MATERIAL, SEE A7.3 SERIES LIGHT FIXTURES (S.E.D.) MECH. REGISTERS (S.M.D.) GYP BOARD, PAINTED TRANSFER GRILLES RANGE HOOD REFLECTED CEILING SYMBOLS MTL-01 GRID GRID PANTRY 3A-06 3A-05 3A-02 3A-03 3A-07 3A-01 3A-04 ENTRY CLOSET BATH 1 BATH 2 WIC BED 1 BED 2 CLOSET LIVING BED 3 3A-10 3A-11 KITCHEN CLOSET W 6 0 W W 6 0 W 6 0 W W 4 1 GRID GRID 1/2" 11'-0" 10'-9 1/2" 11'-3 1/2" 10'-7 5/8" 7/8" 44'-1" 1 31 1 5 8 1 10 3 / 8 2 50 3'-2 1/2" 7'-11 1/2" 7'-4" 3'-1 1/2" 11'-2" 10'-5 1/2" 2'-3 1/2" 19'-3 5/8" 19'-3 5/8" PANTRY (25" MIN.) 2'-2 5/8" 18" MIN. 3'-9" (25" MIN.) 2'-4 3/8" 3'-9" 18" MIN. 1/2" 43'-2 5/8" 7/8" 44'-1" 55 18 1 2 1 17 51 0 71 1 2 2 46 1 2 4'-0 1/2" 6'-3 1/2" C L R 4 5 M N 6'-6" 3'-11" F O R A L T E R N A T E S E E B U L D I N G P L A N GRID GRID UNIT 3A 223 GRID GRID GRID GRID 5 1/2" 44'-0 1/2" 1 46 1 06 2 50 F O R A L T E R N A T E S E E B U L D I N G P L A N 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 6 : 0 7 P M A273.A2 1648.001 AD/AO Checker UNIT PLANS - 3A FIREWALL THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 1 UNIT 3A FIREWALL -ANNOTATION 1/4" = 1'-0" 2 UNIT 3A FIREWALL -DIMENSION 1/4" = 1'-0" 3 UNIT 3A FIREWALL -RCP REVISIONS 1/4" = 1'-0" 4 UNIT 3A EXTERIOR WALL -DIMENSION
60" 30"x48" 30"x60" REF. 30"x48" 30"x48" 30"x48" 60"x54" 60"x60" 30"x48" 30"x48" 60" 60"x54" 60"x54" 60" 60"x54" 60"x54" 60"x54" REF. REF. 1. CEILING HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF CEILING GYP. 2. EXTERIOR SOFFIT HEIGHTS FROM T.O. FINISH FLOOR TO FACE OF EXTERIOR SOFFIT MATERIAL. 3. ALL EXTERIOR SOFFITS SHALL BE CP-1, U.O.N. 4. ALL DIMENSIONS TO F.O. STUD, (U.O.N.) 5. FOR CEILING DIFFUSERS, REGISTERS, AND VENTS TYPES, S.M.D. 6. FOR FURTHER INFORMATION REGARDING CEILING FIXTURES TYPES, S.E.D. 7. LOCATE LIGHTING FIXTURE @ CENTER OF CEILING U.O.N. 8. FOR FURTHER INFORMATION REGARDING FIRE SPRINKLERS AND LOCATIONS SEE DESIGN-BUILD SPRINKLER DRAWINGS. ALL SPRINKLER HEADS SHALL BE LOCATED AT THE CENTER OF CEILING TILES, & SOFFITS TYP. U.O.N. INSTALLER SHALL COORDINATE INSTALLATION WITH OTHER TRADES TO AVOID CONFLICTS. 9. COORDINATE ALL FRAMING AT RECESSED FIXTURE LOCATIONS TO ACCOMMODATE FIXTURE LAYOUT PRIOR TO FRAMING. 10. SOFFIT WIDTH DIMENSIONS ARE FROM FACE OF STUD TO OUTER FINISH EDGE OF SOFFIT GYP. BOARD. 11. SOFFIT LOCATIONS VARY PER UNIT. S.M.D. AND SEE BUILDING PLANS FOR LOCATIONS. 12. STENCIL THE FOLLOWING TEXT: "FIRE AND/OR SMOKE BARRIER -PROTECT ALL OPENINGS" IN CONCEALED SPACE ABOVE CEILINGS ON BOTH SIDES OF 1-HR RATED WALLS CEILING PLAN NOTES 1. ALL EXTERIOR DIMENSIONS TO FACE OF STUD, FACE OF FOUNDATION, (U.O.N.) 2. ALL INTERIOR DIMENSIONS TO FACE OF STUD (U.O.N.) 3. ALL DIMENSIONS AT WINDOWS & DOORS ARE TO THE CENTERLINE. (U.O.N.) 4. ALL ANGLED WALLS SHALL BE 45 DEGREES, U.O.N. 5. ALL INTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 4" U.O.N. ALL EXTERIOR DOOR JAMBS ON HINGE SIDE SHALL BE 6" U.O.N. 6. DIMENSIONS FOR TYPICAL UNIT FLOOR PLAN APPLY TO OTHER UNIT TYPES EXCEPT WHERE INDICATED ON VARIATION UNIT PLANS, VARIATION UNIT PLANS INDICATE MODIFICATIONS TO/FROM TYPICAL UNIT PLAN. 7. ALL EXTERIOR WALLS SHALL BE CONSTRUCTED OF 2X6 STUDS, U.O.N., S.S.D. 8. ALL INTERIOR WALLS SHALL BE CONSTRUCTED OF 2X4 STUDS, U.O.N., S.S.D. 9. WINDOW HEAD HEIGHTS: 8'-2", U.O.N. 10. ALL TEMPERED GLASS SHALL BE AFFIXED WITH A PERMANENT LABEL PER CBC 2406.3. 11. ALL COUNTERS, TUB DECKS, & WALLS AT TUBS & SHOWERS SHALL HAVE SMOOTH, HARD, NONABSORBENT SURFACES. FOR SHOWERS TO A HEIGHT OF +70" MIN. ABOVE DRAIN INLET PER CBC 1210.3. 12. VERIFY APPLIANCE DIMENSIONS PRIOR TO CABINET FABRICATION 13. FOR TYP. FIRE RATED ASSEMBLY DETAILS SEE G2 SHEETS 14. FOR TYP. FIRE RATED PENETRATION DETAILS SEE G2 SHEETS 15. FOR ACCESSIBILITY DETAILS AND NOTES SEE G3 SHEETS 16. FOR DIMENSIONS TO WINDOW AND DOOR OPENINGS REFER TO BUILDING PLAN SHEETS, A2 SERIES 17. SEE A7.3.1 FOR UNIT FINISH SCHEDULE 18. FOR INTERIOR UNIT DOORS, REFERENCE DOOR SCHEDULE -UNITS, A7.1 SERIES SHEETS. 19. FOR ENTRY DOORS SEE FLOOR PLANS ON A2.1 SERIES SHEETS AND DOOR SCHEDULE -BUILDING, A7.1 SERIES SHEETS. 20. ALL INTERIOR WALLS AT PODIUM ARE TO BE 2X4 MTL. STUD. ALL INTERIOR WALLS ABOVE PODIUM TO BE 2X4 WD. STUD U.N.O. SEE G3.1.1. 21. SEE BUILDING PLANS FOR INTERIOR WALL, PARTY WALL, OR CORRIDOR WALL INFORMATION AND DIMENSIONS. A2.1 SERIES SHEETS 22. 11B MOBILITY AND COMMUNICATION UNITS TO COMPLY WITH CBC 11B-809. SEE G4.2 SERIES CODE COMPLIANCE SHEETS FOR DETAILS. SEE ELECTRICAL DRAWINGS FOR ADDITIONAL COMMUNICATION FEATURES UNIT PLAN NOTES 0 W C WALL FRAMING, SEE PARTITION SCHEDULE SHEET G3.1.1 SEMI RECESSED FIRE EXTINGUISHER CABINET WITH FIRE EXTINGUISHER. SEE DETAIL X/XX STRUCTURAL COLUMNS, S.S.D. 5'-0" DIA. TURNING SPACE PER CBC 11B-304.3.1 30" X 48" CLEAR FLOOR SPACE PER CBC 11B-305.3. WALL TYPE -SEE G3.1.1 WINDOW TYPE -SEE WINDOW SCHEDULE A7.2 SERIES SHEETS DOOR TYPE -SEE DOOR SCHEDULE A7.1 SERIES SHEETS ROOM NUMBER 1 SHELF & POLE, SEE DETAIL 30"x60" TUB/SHOWER W/ SURROUND ON 3 WALLS TO +6'-8". SHOWER HEAD AT +78" & PER CPC 402.1.1 SEE INTERIOR ELEVATIONS AND S.P.D. FOR FINISH LAVATORY W/ FAUCET S.P.D. KITCHEN SINK W/ GARBAGE DISPOSAL & FAUCET, S.P.D. WATER CLOSET S.P.D. DISHWASHER W/ DRAIN TO GARBAGE DISPOSAL DRYER PROVIDE SMOOTH METAL VENT TO EXTERIOR FREE STANDING IN RANGE/OVEN COMBINATION W/HOOD, LIGHT & FAN ABOVE. REFRIGERATOR STACKED WASHER & DRYER-PROVIDE HOT & COLD WATER SUPPLY& WASTE SUPPLY & WASTE LINE FOR WASHER. PROVIDE SMOOTH METAL VENT TO EXTERIOR FOR DRYER. PROVIDE GSM W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D., S.M.D. 24" TOWEL BAR AT +40" HT. MAXIMUM TOILET PAPER HOLDER AT +24" HT. WASHER-PROVIDE HOT & COLD WATER SUPPLY & WASTE LINE. W/PAN W/DRAIN TO OUTSIDE AT ALL UPPER FLOOR LOCATIONS, S.P.D. FLOOR TYPE TRANSITION, SEE A7.3 FE 101 30" X 60" CLEAR FLOOR SPACE PER CBC 11B-607.2. RECESSED MEDICINE CABINET W/ BTM USABLE SHELF AT +44" HT. MAXIMUM PER CBC 11B-603.4. SLIDE-IN LINEN CABINET ELECTRICAL PANEL, S.E.D. 42" SIDE AND 36" REAR GRAB BARS RANGE HOOD UNIT PLAN SYMBOLS 101 A xxx-xx 1-HR. FIRE RATED CORRIDOR WALL (FIRE PARTITION), PER CBC 1020 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED OCCUPANCY SEPARATION WALL (FIRE BARRIER), PER CBC 508.4.4. SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 1-HR. FIRE RATED DWELLING UNIT SEPARATION WALL (FIRE PARTITION), PER CBC 420 AND 780.3 SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 2-HR. FIRE BARRIER @ SHAFTS, STAIRS, AND ELEVATORS, PER CBC 707.3, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. 3-HR. FIRE WALL PER CBC 706.4, SEE BUILDING PLANS, SHEET SERIES A2 FOR WALL TAGS. INTERIOR WALL LEGEND ALIGN INTERIOR FINISH MATERIAL, SEE A7.3 SERIES LIGHT FIXTURES (S.E.D.) MECH. REGISTERS (S.M.D.) GYP BOARD, PAINTED TRANSFER GRILLES RANGE HOOD REFLECTED CEILING SYMBOLS MTL-01 GRID 4A-02 4A-04 4A-05 4A-08 4A-09 4A-11 4A-12 4A-10 4A-01 4A-07 4A-03 WIC BATH 2 STORAGE BATH 1 LIVING BED 3 BED 4 KITCHEN ENTRY HALL BED 1 BED 2 CLOSET CLOSET COAT CLOSET 0 W 0 W 6 0 W 6 0 W 0 W 0 W 6 0 W 4 0 W 6 PANTRY W GRID C L R 4 7 M N 42"CLR. 30 55 85 23 1 2 S E E B U L D I N G P L A N S F O R A L T E R N A T E WIC BATH 2 STORAGE BATH 1 LIVING BED 3 BED 4 KITCHEN ENTRY HALL BED 1 BED 2 CLOSET CLOSET COAT CLOSET 9'-10" 11'-6" 12'-3 1/2" 10'-9" 10'-3 1/2" 1/2" 86 1 11 1 46 1 2 2 41 1 1 / 2 1/2" 10'-5 1/2" 22'-10 1/2" 4'-0 1/2" 10'-6 1/2" 6'-9" 2'-8" 7'-9 1/2" 2'-3 1/2" 5'-6 1/2" 15'-0 1/2" 7'-8 1/2" 2'-10" (25" MIN.) 2'-5 1/4" 18" MIN. 3'-9" MIN. CLR. 2'-9" 30" CLR. 3 0 C L R (25" MIN.) 2'-1 3/8" 18" MIN. 3'-9" PANTRY 29 1 2 4'-1" 6'-1" 28 1 15 1 2 5'-1 1/2" 5'-2" C L R 4 7 M N 54'-8 1/2" 2 26 1 2 54'-8 1/2" GRID 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 2 5 6 : 1 9 P M A274.A 1648.001 AD/AO Checker UNIT PLANS - 4A THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/4" = 1'-0" 1 UNIT 4A -11B ANNOTATION 1/4" = 1'-0" 2 UNIT 4A -11B DIMENSION 1/4" = 1'-0" 3 UNIT 4A -RCP KEYNOTE LEGEND Key Value Keynote Text REVISIONS
1. SEE FINISH INFORMATION ON SHEET A731 FOR MATERIAL DESCRIPTIONS, KEYNOTED WITH SYMBOL 2. PAINT ALL EXPOSED MATERIAL SURFACES U.O.N. 3. FOR COLOR APPLICATION REF. SHEETS A5.2 SERIES SHEETS. 4. ALL HIGH SLOPED ROOFS TO BEU.O.N. 5. ALL LOW SLOPED ROOFS TO BE U.O.N. 6. ALL EXTERIOR SOFFITS TO BE U.O.N. 7. FOR ALL EXTERIOR WINDOW AND DOORS, REF. WINDOW AND DOOR SCHEDULES, A700 SERIES SHEETS. 8. ALL GUTTER AND DOWNSPOUTS TO BE U.O.N. PAINT GUTTER TO MATCH FASCIA, PAINT DOWNSPOUT TO MATCH ADJ. WALL. 9. FOR FINISHES RELATED TO HARDSCAPE AND SITE ACCESSORIES S.L.D. AND S.C.D. 10. FOR FINISHES RELATED TO FIXTURES S.M.D., S.P.D. AND S.E.D. 11. FOR ALL PARAPET AND ROOF HEIGHTS SEE ROOF PLANS, A400 SERIES SHEETS 12. FOR TYPICAL PLASTER CONTROL JOINTS, ALIGN WITH SIDE OF OPENING. RF-1 RF-2 DS-1 ELEVATION GENERAL NOTES CP-1 GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" 1 3 4 7 12 15 16 17 9 10 T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" 10'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 1/2" 13'-6" 11'-1 5/8" 10'-1 5/8" 10'-1 5/8" 10'-1 5/8" 10'-1 1/2" 3'-0" 1'-6" UNIT 3A (NO. 223) O/ PODIUM UNIT 3A (NO. 623) O/ UNIT 3A (NO. 523) O/ UNIT 3A (NO. 423) O/ UNIT 3A (NO. 323) CORRIDOR UNIT 2B (NO. 224) O/ PODIUM UNIT 2B (NO. 624) O/ UNIT 2B (NO. 524) O/ UNIT 2B (NO. 424) O/ UNIT 2B (NO. 324) UNIT 2A (NO. 214) O/ PODIUM UNIT 2A (NO. 614) O/ UNIT 2A (NO. 514) O/ UNIT 2A (NO. 414) O/ UNIT 2A (NO. 314) UNIT 1A (NO. 212) O/ PODIUM UNIT 1A (NO. 612) O/ UNIT 1A (NO. 512) O/ UNIT 1A (NO. 412) O/ UNIT 1A (NO. 312) O/ COMMUNITY ROOM (NO. 210) O/ PODIUM UNIT 3A (NO. 610) O/ UNIT 3A (NO. 510) O/ UNIT 3A (NO. 410) O/ UNIT 3A (NO. 310) O/ UNIT 2B (NO. 302) O/ UNIT 2B (NO. 202) UNIT 2B (NO.602) O/ UNIT 2B (NO. 502) O/ UNIT 2B (NO. 402) CORRIDOR JANITOR & TRASH ROOMS 3'-0" 5'-0" CP-01 MTL-1 CP-04 CP-03 MTL-1 CP-04 CP-04 CP-01 MTL-1 CP-04 MTL-1 CP-04 CP-04 7 A642 P1 P2 P3 P4 P5 P6 GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" A M G T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" 1'-0 1/2" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 10'-1" 1'-6" 3'-0" 10'-1 1/2" 10'-1 5/8" 10'-1 5/8" 10'-1 5/8" 11'-1 5/8" 13'-6" O/ UNIT 4A (NO. 221) O/ PODIUM UNIT 4A (NO. 621) O/ UNIT 4A (NO. 521) O/ UNIT 4A (NO. 421) O/ UNIT 4A (NO. 321) O/ UNIT 3A (NO. 223) O/ PODIUM UNIT 3A (NO. 623) O/ UNIT 3A (NO. 523) O/ UNIT 3A (NO. 423) O/ UNIT 3A (NO. 323) CP-04 MTL-1 7 A641 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 0 1 0 P M A511 1648.001 AD/AO Checker EXTERIOR ELEVATIONS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND EXTERIOR FINISH LEGEND MATERIAL MARK ITEM CP-01 PNT-01 CP-02 PNT-02 CP-03 PNT-03 CP-04 PNT-04 CP-06 PNT-06 1/8" = 1'-0" 1 NORTH ELEVATION 1/8" = 1'-0" 2 EAST ELEVATION 2 1 REVISIONS
1. SEE FINISH INFORMATION ON SHEET A731 FOR MATERIAL DESCRIPTIONS, KEYNOTED WITH SYMBOL 2. PAINT ALL EXPOSED MATERIAL SURFACES U.O.N. 3. FOR COLOR APPLICATION REF. SHEETS A5.2 SERIES SHEETS. 4. ALL HIGH SLOPED ROOFS TO BEU.O.N. 5. ALL LOW SLOPED ROOFS TO BE U.O.N. 6. ALL EXTERIOR SOFFITS TO BE U.O.N. 7. FOR ALL EXTERIOR WINDOW AND DOORS, REF. WINDOW AND DOOR SCHEDULES, A700 SERIES SHEETS. 8. ALL GUTTER AND DOWNSPOUTS TO BE U.O.N. PAINT GUTTER TO MATCH FASCIA, PAINT DOWNSPOUT TO MATCH ADJ. WALL. 9. FOR FINISHES RELATED TO HARDSCAPE AND SITE ACCESSORIES S.L.D. AND S.C.D. 10. FOR FINISHES RELATED TO FIXTURES S.M.D., S.P.D. AND S.E.D. 11. FOR ALL PARAPET AND ROOF HEIGHTS SEE ROOF PLANS, A400 SERIES SHEETS 12. FOR TYPICAL PLASTER CONTROL JOINTS, ALIGN WITH SIDE OF OPENING. RF-1 RF-2 DS-1 ELEVATION GENERAL NOTES CP-1 GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" 1 3 4 7 12 15 16 17 6 9 10 13 14 11 8 5 2 T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" 25'-0" 6'-0" 3'-8" 15'-1" 6'-3" 11'-10 11/16" 14'-9 5/8" 22'-5 11/16" 6'-8" 31'-2" 6'-3" 6'-8" 12'-1" 6'-0" 9'-2" 15'-10" 1'-0 1/2" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 10'-1" 1'-6" 3'-0" 10'-1 1/2" 10'-1 5/8" 10'-1 5/8" 10'-1 5/8" 11'-1 5/8" 7 A642 P1 P2 P3 P4 P5 P6 GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" A K I T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" 1'-0 1/2" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 9'-1" 1'-0 5/8" 10'-1" 1'-6" 3'-0" 10'-1 1/2" 10'-1 5/8" 10'-1 5/8" 10'-1 5/8" 11'-1 5/8" 13'-6" E C JANITOR & TRASH ROOMS 44'-1" 9'-8" 26'-8" A641 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 0 2 6 P M A512 1648.001 AD/AO Checker EXTERIOR ELEVATIONS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 SOUTH ELEVATION 1/8" = 1'-0" 2 WEST ELEVATION KEYNOTE LEGEND Key Value Keynote Text EXTERIOR FINISH LEGEND MATERIAL MARK ITEM CP-01 PNT-01 CP-02 PNT-02 CP-03 PNT-03 CP-04 PNT-04 CP-06 PNT-06 2 1 REVISIONS
1. SEE FINISH INFORMATION ON SHEET A731 FOR MATERIAL DESCRIPTIONS, KEYNOTED WITH SYMBOL 2. PAINT ALL EXPOSED MATERIAL SURFACES U.O.N. 3. FOR COLOR APPLICATION REF. SHEETS A5.2 SERIES SHEETS. 4. ALL HIGH SLOPED ROOFS TO BEU.O.N. 5. ALL LOW SLOPED ROOFS TO BE U.O.N. 6. ALL EXTERIOR SOFFITS TO BE U.O.N. 7. FOR ALL EXTERIOR WINDOW AND DOORS, REF. WINDOW AND DOOR SCHEDULES, A700 SERIES SHEETS. 8. ALL GUTTER AND DOWNSPOUTS TO BE U.O.N. PAINT GUTTER TO MATCH FASCIA, PAINT DOWNSPOUT TO MATCH ADJ. WALL. 9. FOR FINISHES RELATED TO HARDSCAPE AND SITE ACCESSORIES S.L.D. AND S.C.D. 10. FOR FINISHES RELATED TO FIXTURES S.M.D., S.P.D. AND S.E.D. 11. FOR ALL PARAPET AND ROOF HEIGHTS SEE ROOF PLANS, A400 SERIES SHEETS 12. FOR TYPICAL PLASTER CONTROL JOINTS, ALIGN WITH SIDE OF OPENING. RF-1 RF-2 DS-1 ELEVATION GENERAL NOTES CP-1 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" 9 10 11 8 T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" P2 P3 P4 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" J K M L I T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" H J K G I T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 0 4 1 P M A513 1648.001 AD/AO Checker EXTERIOR ELEVATIONS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 2 NORTH COURTYARD ELEVATION 1/8" = 1'-0" 1 EAST COURTYARD ELEVATION KEYNOTE LEGEND Key Value Keynote Text EXTERIOR FINISH LEGEND MATERIAL MARK ITEM CP-01 PNT-01 CP-02 PNT-02 CP-03 PNT-03 CP-04 PNT-04 CP-06 PNT-06 1/8" = 1'-0" 3 WEST COURTYARD ELEVATION 3 1 2 REVISIONS
GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" 1 3 4 7 12 15 16 17 6 9 10 13 14 11 8 5 2 T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" PNT-04 PNT-04 PNT-03 PNT-01 PNT-05 PNT-03 PNT-04 PNT-05 PNT-01 PNT-01 PNT-04 PNT-04 CP-01 MTL-1 PNT-01 PNT-01 P1 P2 P3 P4 P5 P6 GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" A B D H J K M L G I F T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" E C PA PB PC PNT-04 PNT-01 PNT-04 MTL-1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 0 5 4 P M A521 1648.001 AD/AO Checker EXTERIOR COLOR ELEVATIONS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 NORTH ELEVATION -COLOR 1/8" = 1'-0" 2 EAST ELEVATION -COLOR 2 1 FINISH SCHEDULE MTL-1 WALLWALLSLATE GRAY AEP SPAN WWW.AEPSPAN.COM PNT-01 WALLWALLSALTY DOG SW 9177 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-02 WALLWALLWESTCHESTER GRAY SW 2849SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-03 WALLWALLGRAY CLOUDS SW 7658 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-04 WALLWALLEXTRA WHITE SW 7006 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-05 WALLWALLICY SW 6534 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-06 WALLWALLEMBERGLOW SW 6627 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM REVISIONS KEYNOTE LEGEND Key Value Keynote Text
GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" 1 3 4 7 12 15 16 17 6 9 10 13 14 11 8 5 2 T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" PNT-04 PNT-04 MTL-1 MTL-1 PNT-03 MTL-1 PNT-04 PNT-04 MTL-1 MTL-1 PNT-01 P1 P2 P3 P4 P5 P6 GROUND FLOOR 0" 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" A B D H J K M L G I F T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" E C PA PB PC PNT-04 PNT-02 PNT-01 MTL-1 MTL-1 MTL-1 PNT-04 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 1 0 8 P M A522 1648.001 AD/AO Checker EXTERIOR COLOR ELEVATIONS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 1 SOUTH ELEVATION -COLOR 1/8" = 1'-0" 2 WEST ELEVATION -COLOR 2 1 FINISH SCHEDULE MTL-1 WALLWALLSLATE GRAY AEP SPAN WWW.AEPSPAN.COM PNT-01 WALLWALLSALTY DOG SW 9177 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-02 WALLWALLWESTCHESTER GRAY SW 2849SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-03 WALLWALLGRAY CLOUDS SW 7658 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-04 WALLWALLEXTRA WHITE SW 7006 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-05 WALLWALLICY SW 6534 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-06 WALLWALLEMBERGLOW SW 6627 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM REVISIONS KEYNOTE LEGEND Key Value Keynote Text
2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" 9 10 11 8 T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" PNT-04 MTL-1 PNT-03 MTL-1 MTL-1 PNT-04 PNT-01 PNT-05 PNT-01 PNT-05 P2 P3 P4 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" H J K M L I T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" PNT-04 MTL-1 MTL-1 PNT-01 2ND FLOOR T.O.C. 13'-6" ROOF 65'-2" 4TH FLOOR 34'-10 1/2" 5TH FLOOR 45'-0 1/8" 6TH FLOOR 55'-1 3/4" 3RD FLOOR 24'-8 7/8" T.O.P. 2ND FLOOR 23'-7" T.O.S.F. 3RD FLOOR 24'-7 5/8" T.O.P. 3RD FLOOR 33'-8 5/8" T.O.S.F. 4TH FLOOR 34'-9 1/4" T.O.P. 4TH FLOOR 43'-10 1/4" T.O.S.F. 5TH FLOOR 44'-10 7/8" T.O.P 5TH FLOOR 53'-11 7/8" T.O.S.F. 6TH FLOOR 55'-0 1/2" H J K G T.O.P. 6TH FLOOR 64'-1 1/2" PARAPET 1 68'-2" PARAPET 2 69'-8" PNT-04 MTL-1 148 16 SCALE: 1/8" = 1'-0" PROJECT NORTH JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 1 2 1 P M A523 1648.001 AD/AO Checker EXTERIOR COLOR ELEVATIONS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 1/8" = 1'-0" 2 NORTH COURTYARD ELEVATION -COLOR 1/8" = 1'-0" 1 EAST COURTYARD ELEVATION -COLOR 1/8" = 1'-0" 3 WEST COURTYARD ELEVATION -COLOR 3 1 2 FINISH SCHEDULE MTL-1 WALLWALLSLATE GRAY AEP SPAN WWW.AEPSPAN.COM PNT-01 WALLWALLSALTY DOG SW 9177 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-02 WALLWALLWESTCHESTER GRAY SW 2849SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-03 WALLWALLGRAY CLOUDS SW 7658 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-04 WALLWALLEXTRA WHITE SW 7006 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-05 WALLWALLICY SW 6534 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM PNT-06 WALLWALLEMBERGLOW SW 6627 SHERWIN WILLIAMSWWW.SHERWINWILLIAMS.COM REVISIONS KEYNOTE LEGEND Key Value Keynote Text
1. FOR ADDITIONAL INFORMATION, SEE PLANS. 2. FOR INDICATED EQUIPMENT1 SEE A211 3. FOR MATERIAL INFORMATION, SEE A731 4. FOR TYP. MOUNTING HEIGHTS OF TOILET ROOM ACCESSORIES, SEE G100 SERIES SHEETS 5. FOR ALL SOFFIT HEIGHTS AND LOCATIONS, REF. A200 AND A300 SERIES SHEETS INTERIOR ELEVATION NOTES JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 4 3 3 P M A811 1648.001 Author Checker INTERIOR ELEVATIONSCOMMON THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 KEYNOTE LEGEND BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS REVISIONS 1/4" = 1'-0" 1 RESTROOM -ELEVATION A 1/4" = 1'-0" 2 RESTROOM -ELEVATION B 1/4" = 1'-0" 3 RESTROOM -ELEVATION C 1/4" = 1'-0" 4 RESTROOM -ELEVATION D 1/4" = 1'-0" 5 RESTROOM 1 -ELEVATION A 1/4" = 1'-0" 6 RESTROOM 1 -ELEVATION B 1/4" = 1'-0" 7 RESTROOM 1 -ELEVATION C 1/4" = 1'-0" 8 RESTROOM 1 -ELEVATION D 1/4" = 1'-0" 9 RESTROOM 2 -ELEVATION A 1/4" = 1'-0" 10 RESTROOM 2 -ELEVATION B 1/4" = 1'-0" 11 RESTROOM 2 -ELEVATION C 1/4" = 1'-0" 12 RESTROOM 2 -ELEVATION D 1/4" = 1'-0" 13 KITCHEN -ELEVATION A 1/4" = 1'-0" 14 KITCHEN ELEVATION B 1ST FLOOR 2ND FLOOR 2ND FLOOR COMMUNITY ROOM
1. FOR ADDITIONAL INFORMATION, SEE PLANS. 2. FOR INDICATED EQUIPMENT1 SEE A211 3. FOR MATERIAL INFORMATION, SEE A731 4. FOR TYP. MOUNTING HEIGHTS OF TOILET ROOM ACCESSORIES, SEE G100 SERIES SHEETS 5. FOR ALL SOFFIT HEIGHTS AND LOCATIONS, REF. A200 AND A300 SERIES SHEETS INTERIOR ELEVATION NOTES 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 6 4 7 P M A821 1648.001 Author Checker INTERIOR ELEVATIONS - UNITS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS KEYNOTE LEGEND Key Value Keynote Text 1/4" = 1'-0" 1 KITCHEN -ELEVATION A 1/4" = 1'-0" 2 KITCHEN -ELEVATION B 1/4" = 1'-0" 3 BATH -ELEVATION A 1/4" = 1'-0" 4 BATH -ELEVATION B 1/4" = 1'-0" 5 BATH -ELEVATION C 1/4" = 1'-0" 6 BATH -ELEVATION D 1/4" = 1'-0" 7 KITCHEN -ELEVATION A 1/4" = 1'-0" 8 KITCHEN -ELEVATION B 1/4" = 1'-0" 9 BATH -ELEVATION A 1/4" = 1'-0" 10 BATH -ELEVATION B 1/4" = 1'-0" 11 BATH -ELEVATION C 1/4" = 1'-0" 12 BATH -ELEVATION D 1/4" = 1'-0" 13 KITCHEN -ELEVATION A 1/4" = 1'-0" 14 KITCHEN -ELEVATION A 1/4" = 1'-0" 15 BATH -ELEVATION A 1/4" = 1'-0" 16 BATH -ELEVATION B 1/4" = 1'-0" 17 BATH -ELEVATION C 1/4" = 1'-0" 18 BATH -ELEVATION D 1/4" = 1'-0" 24 BATH -ELEVATION D 1/4" = 1'-0" 23 BATH -ELEVATION C 1/4" = 1'-0" 22 BATH -ELEVATION B 1/4" = 1'-0" 21 BATH -ELEVATION A 1/4" = 1'-0" 20 KITCHEN -ELEVATION B 1/4" = 1'-0" 19 KITCHEN -ELEVATION A UNIT 1A -11B UNIT 1B -11A UNIT 2A -11A UNIT 2A -11B REVISIONS
1. FOR ADDITIONAL INFORMATION, SEE PLANS. 2. FOR INDICATED EQUIPMENT1 SEE A211 3. FOR MATERIAL INFORMATION, SEE A731 4. FOR TYP. MOUNTING HEIGHTS OF TOILET ROOM ACCESSORIES, SEE G100 SERIES SHEETS 5. FOR ALL SOFFIT HEIGHTS AND LOCATIONS, REF. A200 AND A300 SERIES SHEETS INTERIOR ELEVATION NOTES 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 / 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 91 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 6 5 7 P M A822 1648.001 Author Checker INTERIOR ELEVATIONS - UNITS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS 1/4" = 1'-0" 2 KITCHEN -ELEVATION B 1/4" = 1'-0" 1 KITCHEN -ELEVATION A 1/4" = 1'-0" 3 BATH -ELEVATION A 1/4" = 1'-0" 4 BATH -ELEVATION B 1/4" = 1'-0" 5 BATH -ELEVATION C 1/4" = 1'-0" 6 BATH -ELEVATION D 1/4" = 1'-0" 7 KITCHEN -ELEVATION A 1/4" = 1'-0" 8 KITCHEN -ELEVATION B 1/4" = 1'-0" 9 BATH 1 -ELEVATION A 1/4" = 1'-0" 10 BATH 1 -ELEVATION B 1/4" = 1'-0" 11 BATH 1 -ELEVATION C 1/4" = 1'-0" 12 BATH 1 -ELEVATION D 1/4" = 1'-0" 13 BATH 2 -ELEVATION A 1/4" = 1'-0" 14 BATH 2 -ELEVATION B 1/4" = 1'-0" 15 BATH 2 -ELEVATION C 1/4" = 1'-0" 16 BATH 2 -ELEVATION D 1/4" = 1'-0" 17 BATH -ELEVATION D 1/4" = 1'-0" 18 BATH -ELEVATION C 1/4" = 1'-0" 19 BATH -ELEVATION B 1/4" = 1'-0" 20 BATH -ELEVATION A 1/4" = 1'-0" 21 KITCHEN -ELEVATION B 1/4" = 1'-0" 22 KITCHEN -ELEVATION A KEYNOTE LEGEND Key Value Keynote Text UNIT 2B -11A UNIT 3A -11A UNIT 3A -11A UNIT 3A -11B REVISIONS
1. FOR ADDITIONAL INFORMATION, SEE PLANS. 2. FOR INDICATED EQUIPMENT1 SEE A211 3. FOR MATERIAL INFORMATION, SEE A731 4. FOR TYP. MOUNTING HEIGHTS OF TOILET ROOM ACCESSORIES, SEE G100 SERIES SHEETS 5. FOR ALL SOFFIT HEIGHTS AND LOCATIONS, REF. A200 AND A300 SERIES SHEETS INTERIOR ELEVATION NOTES 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 81 1 3 4 124 SCALE: 1/4" = 1'-0" JOB NO. DRAWN CHECK SHEET SEAL SIGNATURE 5865 Owens Drive Pleasanton, CA 94588 925-251-7200 8 / 2 7 / 2 0 2 1 3 0 8 0 9 P M A823 1648.001 Author Checker INTERIOR ELEVATIONS - UNITS THE MERIDIAN 3941 STEVENS CREEK SANTA CLARA, CA 50% DD SET 08.06.21 BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS BOT. OF ELEVATIONS DIM. ELEVATION TITLE DIM. DIM. ALIGN RIGHT SIDE OF ELEVATIONS 1/4" = 1'-0" 1 KITCHEN -ELEVATION A 1/4" = 1'-0" 2 KITCHEN -ELEVATION B 1/4" = 1'-0" 3 BATH 1 -ELEVATION A 1/4" = 1'-0" 4 BATH 1 -ELEVATION B 1/4" = 1'-0" 5 BATH 1 -ELEVATION C 1/4" = 1'-0" 6 BATH 1 -ELEVATION D 1/4" = 1'-0" 7 BATH 2 -ELEVATION A 1/4" = 1'-0" 8 BATH 2 -ELEVATION B 1/4" = 1'-0" 9 BATH 2 -ELEVATION C 1/4" = 1'-0" 10 BATH 2 -ELEVATION D KEYNOTE LEGEND Key Value Keynote Text UNIT 4A -11B UNIT 4A -11B REVISIONS