AR
PORTFOLIO AAKANGSHA ROY
|
VIVEKANANDA GLOBAL UNIVERSITY,
|
JAIPUR 1
ACADEMIC WORK SEM 01:
VIVEKANANDA MEMORIAL
SEM 02:
CONTAINER OFFICE
SEM 03:
BUNGALOW
SEM 04:
SPORTS COMPLEX
SEM 05:
MULTI FAMILY HOUSING
SEM 06:
SCIENTIST MUSEUM AND MEMORIAL
SEM 07:
MEDICAL CAMPUS
SEM 07:
HOTEL INTERIOR DESIGN
SEM 09:
MIXED USE PROJECT
3
CONTENTS
01.
03.
MIXED USE PROJECT
05.
MEDICAL CAMPUS
02.
UJJAIN MUSEUM
MULTI FAMILY HOUSING
04.
HOTEL INTERIOR
07.
09.
TECHNICAL DRAWINGS
SOLAR DECATHLON
06.
INDOOR SPORTS COMPLEX
08.
INTERNSHIP WORKS
10.
MISCELLENEOUS
5
01
MIXED USE PROJECT
CONCEPT
PROJECT DATA
The dynamic mixed-use project, harmonizing commerce and tranquility, features a commercial block with small terraces, gracefully curved to enhance street appeal. This lively space invites vibrant business activities. Meanwhile, the residential block, nestled in a serene silent zone, boasts double-height alternate balconies, providing residents with a peaceful retreat.
Type Built Up Area Plot Area
Academic 23364 Sqm 10407 Sqm
Location
Kuber Complex, at Village Reed, Khatipura, Gandhi Path, Vaishali Nagar, Jaipur
Semester
9th sem
This project aims to address the shortage of residential and commercial spaces in Jaipur by developing a sustainable, mixeduse tall building. The proposal emphasizes maximizing land use efficiency by incorporating both residential and commercial functions vertically. This eco-friendly development will enhance community amenities and contribute to the overall urban landscape. With a focus on integration, the project aligns with mixed-use zoning principles, providing a holistic solution to the city’s spatial and functional needs, creating an ideal opportunity for real estate investors. Permisible height for the project is 60m with a BAR of 2.25. Maximum ground coverage alloted is 40% of the site area i.e 4162 sqm. The ground coverage achieved is 2998sqm. ECU : 273
7
SITE PLAN
SECTION AA’ GROUND FLOOR PLAN
9 EAST SIDE ELEVATION
02
UJJAIN MUSEUM
CONCEPT This project will bring many children as well as many more visitors who will learn about the struggles our brave scientists faced prior to independence. The museum represents a foetus on the site. The design is fluid and with clear path ,will help visitors explore more without any confusion . The project consists of all the site water collected at a particular area as an ecological pond through channels throughout the periphery of the proposed site.
PROJECT DATA Type Built Area Plot Area Team Mates Location Competition SITE LOCATION AND TOPOGRAPHY
Semester
Competition 8392 Sqm 24500 Sqm Siddharth Sharma Kamna Mishra Ujjain, Madhya Pradesh Azadi ka Amrit Mahotsav Architecture competition, Indore 6th sem
The project is in an important location within the planetarium complex. Madhya Pradesh Science and Technology Minister Omprakash Sakhlecha launched a national level architectural creation competition on the theme “Contribution of Indian Scientists in India’s Freedom Movement”. It is a national level competition not only to honor and recognize the incomparable contribution of Indian scientists in India’s freedom struggle by presenting it in the form of a memorial and museum, but also to present it to the present generations of Indians. The Museum had requirements of atleast six galleries, three seminar halls, exhibition space, play area, a landscape memorial, auditorium(s) having capacity of 1000.
11 SITE PLAN
Gyan mudra, otherwise known as chin mudra, is a sacred hand gesture or ‘seal’ used to direct energy and maintain focus. This symbolises knowledge and expansion. Goddess Saraswati is known for wisdom, education, intellect and speech.This Yantra enhances the knowledge, improves concentration and memory power.
The project itself is a knowledge centre so the landmark memorial should symbolise the same. Yantras are Cosmic instruments or tools which are believed to draw positive frequencies from the Planets and other Cosmic bodies and transmit it in the place it is installed.
13
03
MEDICAL CAMPUS
CONCEPT
PROJECT DATA
Focused on a unified “Campus Plan,” the design prioritizes a seamless circulation system to enhance walkability, ensuring universal access and barrier-free design. The creation of multifunctional buildings, including the Hospital Block, Academic Block, Hostel, and Dining Block, embodies the campus identity, fostering a collective spirit. Emphasizing sustainability, passive energy methods will be employed, and green spaces integrated across the site. The Academic Block, a vibrant hub, aims for a contemporary and inspiring atmosphere,
Type Built Up Area Plot Area
Academic 232290 Sqm 116144 Sqm
Location
Near Azad Cricket Ground, Opposite VGU, Karolan Ka Bagh, Jaipur.
Semester
7th sem
The project involves designing a comprehensive medical campus in Jagatpura, Jaipur, spanning approximately 30 acres. Emphasizing sustainable and barrier-free design, the campus will house a 300-bedded medical hospital, academic block, hostel, dining block, animal hold room, indoor sports block, residence, playground, shops, and a sports complex. With an entry from Ashok Marg, the design aims to create a unified campus plan, establish a distinctive identity, enhance circulation and walkability, fostering social interaction in informal spaces. The proposed development aligns with the institutional land use outlined in the Master Plan of Jaipur 2025, anticipating future healthcare and educational needs.
featuring abundant natural light, shaded courtyards, and tiered lecture halls. This visionary project anticipates future needs while promoting a holistic, inviting, and sustainable medical campus.
BAR 2
15 SITE PLAN
17
04
HOTEL INTERIOR DESIGN
PROJECT DATA Type
Academic
Location
Sirsi Road, Panchyawala, Jaipur.
Semester
7th sem
The project aims to enhance the interior spaces of the reception area, waiting hall, corridor, and offices within the premises. The goal is to create a welcoming, functional, and aesthetically pleasing environment that aligns with the company’s brand identity and promotes a positive and productive atmosphere for both employees and visitors. Ideation process, theme, mood is shown in the concept.
19
21
05
PARADISE PALMS
MULTI FAMILY HOUSING
CONCEPT
The concept is simple segregation of cuboidal zones of 3bhk, 4bhk nd 5bhk flats and easy access to all of them. Diffused light in inner spaces to be assured and site circulation to be throughout accessible. Shading tchniques and play with forms tried out considering the cardinal directions to allow wind as well as light inside most of the possible rooms.
PROJECT DATA Type Built Area Plot Area Team Mates Location Semester
Academic 6190 Sqm 3100 Sqm Pratiksha Roy Tisha Garg Opposite Royal Treasure, Airport Enclave, Ravindra Nagar, Jagatpura, Jaipur 5th sem
The project located in Jagatpura, demands a luxury multi family housing with all basic amenities and some common activities. The site is near airport, so there is height restriction for the particular zone. Permisible height for the project is 24m with a BAR of 2. Maximum ground coverage alloted is 40% of the site area i.e 1240 sqm. Site circulation of 35% and landscape area of 20% is permitted. The ground coverage achieved is 1142 sqm.
• Segregation of spaces for good accessibility, • Use of low transmittance glazing
ECU : 50
windows, • Utilization of renewable energy: solar pv panels, • Use of low flow water fixtures, • Use of AAC blocks for reducing dead load and thermal insulation, • Installation of green walls and terrace garden, • Ceramic tiles on terrace for insulation, • Albedo paint on roof for solar reflectance, • High pressure laminates for elementation of facades.
23 GROUND AND SITE PLAN
FOURTH FLOOR PLAN FIRST, SECOND, THIRD FLOOR PLAN
GREEN WALL SECTION
25 UNIT PLANS RENDERED
06
SWAMI INDOOR SPORTS COMPLEX
CONCEPT
The concept is creacting the form out of a simple cube for increasing the usable space. Spaces to be easily accesible for all. Use of minimum corridors and maximumuse of space for the requirements, including free space and service at each floor. Use of false walls and louvers as shading devices as well as design elements.
PROJECT DATA Type Built Area Plot Area Location Semester
Academic 11280 Sqm 7200 Sqm Behind Gargi Girls Hostel, Vivekananda Global University, Jaipur 4th sem
The aim of the project was to create an indoor sports complex for the use of college students as well as sportspersons across Jaipur. It is not to be a complex only for the university. The task was to design the project to accomodate all the provided list of sports and games within the limited BAR, with comfortable and appropriate circulation. 35% of ground coverage for built up area is allowed and minimum circulation of 30% required on ground. The requirements for the sports complex included basketball court, skating rink, shooting range, kabaddi court, 2 lawn tennis courts, 4 badminton courts, 2 squash courts, meditation and yoga room, taekwondo, judo, karate, boxing room, TT room, chess and carrom room, cafe, swimming pool, guest houses and some other amenities.
27
FLOOR PLANS
The double height badminton courts and basketball courts are planned one above other to save space. Heavy columns are used however to support such structure. All the common toilets are kept vertically stacked. Some sport rooms are merged on based on size and capacity of use. Easy access to every room assured.
MATERIALS Adjustable louvers used on south facade for convenient allowance of light with changing sun position as required. Fixed louvers on east facade majorly to shade terrace seating and aesthetics. The polygons and facade of south and west are false facades of GRC i.e. Glass Fibre Reinforced Concrete. Lawn tennis hardcourt is of decoturf. The sittings for the same are shaded with membrane structures. The pool cover is a hyperbolic steel structure. The stage shade of OAT is a shell structure.
29
07
MR. CHINTAMANI’S RESIDENCE SOLAR DECATHLON PROJECT
8
CONCEPT In 50% of the site, we designed a net-zero single family housing prototype. Our net zero housing concept takes into account the economy, climate, and local regulations, that aims at achieving sustainable and net zero residence in Jaipur which provides comfort, consume less energy and do not compromise with the privacy user. The team decided to create a void and plan courtyard. This not only aided in tree conservation but also helped in increasing the daylight and maintaining the ambient temperature of space.
Living room /dinning area
Kitchen/kitchen garden
Servant room
1
7
2
Courtyard
6
3
Master bedroom
CLIENT REQUIREMENTS
4
Powder toilet
SITE
MASS CREATED , PRESERVING THE TREE
ZONED OUT AT LEVELS
5
Landscaping Element
Terrace garden
GOALS 1. Reducing load through passive design strategies. 2. Reducing mechanical cooling hours and achieving adaptive thermal comfort range. 3. Use of renewable energy sources. 4. Limit water consumption and returning it to the same watershed. 5. Reduction in transportation cost. 6. Make construction and operation functionally efficient. 7. Conserving and replanting existing trees on site.
8. Improve the ambient quality of indoor space. DETAILS AND PASSIVE DESIGN APLLIED
SITE PLAN
PROJECT DATA Type Built Area Plot Area Team Mates
Competition 367 Sqm 306 Sqm Team AMIGOS (9members) Location Akshat Kanota Estate, Jaipur Competition Solar Decathlon India 2021-22 Project type Single Family House Semester 5th and 6th sem Project name Chintamani’s House Project Partner Arvind Chintamani Industry Partner Design 2 Occupancy
The client is currently a resident at Pratap Nagar, Jaipur. The site objective of the client was to purchase a plot of either east or south facing and to conserve the existing vegetation. Their vision is to build home that are ventilated all at the same time. comfortable, with proper daylighting and connected with nature . The biggest challenge was to design a house for a client who is very old (~50+). The second challenge was to preserve the khejri tree which is existing on site . Material Selection because of the hot and dry climate of Jaipur, Rajasthan was a challenge as well. The intent was to move towards net-zero.
31
FLOOR PLANS
DESIGN AND INNOVATION Challenge 1
Barrier free design consideration.
Challenge 2
GROUND FLOOR ISOMETRIC
Created courtyard near dinning area to preserve the existing tree (Khejri).
VENTILATION
FIRST FLOOR ISOMETRIC ( EXPLODED)
Adequate fresh air provided because of centralized courtyard. Cross ventilation increase indoor air quality. Courtyard is connecting indoor environment with nature. Being around plants has a calming and comfortable effect on people.
XPS Insulation 12mm) AAC Block (200mm) Gypsum Plaster Board (6mm) Reflective coating (1mm) SRI Paint (1mm)
Challenge 3
Challenge 4
Material selection on the basis Of their U – Value.
Used passive strategy to provide maximum Thermal comfort in inner spaces. CHALLENGES OF PROJECT
ISOMETRIC VIEW OF THE RESIDENCE
33 VENTILATION
TRUNCATED PUNCTURES Hot air flow in the building through the punctures.
Hot air cools down due to venturi effect.
Air expansion due to the pressure created by the constricted space. POT IRRIGATION Pot irrigation is a self-watering irrigation system. Due to the porous nature of the surface of the pitcher the water inside the pitcher or mud pot will automatically transfer towards the nearest soil and plants takes up water only according to its need. Here we have used pitcher having a capacity of 4 liters which will last for 3-4 days.
GRADED PATHWAY Sequence of graded pathway throughout pavement and track off before entrance used. This promotes indoor environment quality by protecting the house from the dirt and moisture that can be carried by occupant footwear inside.
CHANNELS AIR FILTRATION AND TEMPERATURE In kitchen, courtyard and north-west rooms the wind from west are helping in cross ventilation. The south façade allows winter sun rays in the house which provides proper heat and ventilation during winter. Through courtyard the temperature near it cools down and the circulation of fresh air inside the house is maintained. Channels are created in the periphery of the site which will collect the rain water and further store in the rain water harvesting tank.
Exhaust fan are fitted on the top as the warm and light air rises up from the space and escapes through the fan and cool and fresh air comes inside the space through the openings
ENERGY PERFORMANCE
WATER PERFORMANCE
A series of iterations were performed with cost and U-value as parameters to obtain a building envelope with the desired U-value. Building envelopes were designed based on their use:
100
1.5
80
1
DRINKING - 4L
COOKING - 6L
BATHING - 55L
WASHING OF CLOTHES - 20L
WASHING OF UTENSILS - 20L
FLUSHING - 30L
22%
40 20 WALL
ROOF
U - VALUE
WINDOW
0
Building Envelope (Using AAC)
XPS Insulation 12mm) AAC Block (200mm) Gypsum Plaster Board (6mm) Reflective coating (1mm) Plaster (12mm) SRI Paint (1mm)
WALL DETAIL
We are using 16 No. modules of 320 watt each plate which generates 7000 units per year and 19 unit per day. For effective efficiency as we analysed from climate consultant’ solar radiation guides us solar radiation hour each month overall year so we got average 9.6 hr of efficiency Generally, 1 kw solar grid generates electricity 4x of its capacity and it achieved with 10 hr of effective day lighting, so we quite near to 10 hr but our electricity consumption is 15 unit/ day and we are generating 4 unit/day more than our consumption.
*LPF- litres per flush LPM-*LPFlitreslitres per minute per flush LPM- litres per minute
70L PER CAPITA PER DAY 41%
DRINKING - 4L
COOKING - 4L
BATHING - 25L
WASHING OF CLOTHES - 10L
WASHING OF UTENSILS - 5L
FLUSHING - 22L (USAGE 5 TIMES A DAY
15% 6%
ENVELOPE SELECTION
ROOF DETAIL
REDUCED WATER CONSUMPTION (USE OF EFFICIENT FIXTURES)
3% 4%
15%
Building Envelope
Kitchen Faucet– –6lpf* 8.3 Lpm* WC (Toilet) Showerhead – 9.5 Lpm Kitchen Faucet – 8.3 Lpm* Showerhead – 9.5 Lpm
135L PER CAPITA PER DAY
60
0.5 0
ENERGY CONSUMPTION
BASELINE CONSUMPTION OF FIXTURES BASELINE WATER CONSUMPTION AS PER BASELINE CONSUMPTION OF FIXTURES BASELINE WATER CONSUMPTION AS PER STANDARD WC (Toilet) – 6lpf* STANDARD
MONTHLY WATER HARVESTING POTENTIAL CALCULATION
6%
31%
WATER CATCHMENT AREA FROM ROOF=7% 151m2 RUN-OFF COEFFICIENT OF CONCRETE= 0.95
36%
14%
WATER HARVESTING POTENTIAL = Area Of Catchment x Amount Of Rainfall x Runoff Coefficient In January = 151m2 x 0.95 x 0.0055m = 0.788 m3 = 788 litres In February = 151m2 x 0.95 x 0.0049m = 0.702 m3 = 702 litres (Similar calculation will be followed for each month with varying avg. water rainfall)
STORAGE TANK PROPOSED = 25 m3 = (2.5m x 2.5m x 4m) 4m depth has been provided to settle down the silt and other particles by sedimentation and get fresh water above.
WATER EFFICIENT FIXTURES
SOLAR PANELS
Dual flush WC
Ultra low flow WC
Low flow aerators – SAVES up to 50%
35
08
INTERNSHIP WORK
37
TENDER DRAWINGS, DOOR WINDOW SCHEDULES
DETAIL DRAWINGS
39
STAIRCASE DETAILS, TILING OPTIONS AND COUNT
WARDROBE AND VANITY DETAIL DRAWINGS
41
15 MM DIA
15 MM DIA
PLUMBING DRAWINGS
MALE
CHANGING ROOM FOR SWIMMING POOL
GENTS TOILET
SHAFT
ASSIGNMENT 2.3
N
20 MM DIA 15 MM DIA
IC
IC
IC
GT
GT
IC
LADIES IC TOILET
GT
M
GT
DISABLED
UP
UP
FEMALE MALE
LIFTS AND STAIRCASE IC GT
DISABLED
LADIES TOILET
GT
LIFTS AND STAIRCASE
SHAFT
FEMALE ASSIGNMENT 2.3
MALE DISABLED
20 MM DIA
MALE
LIFTS AND STAIRCASE IC
GT
SHAFT
IC
20 MM DIA 15 MM DIA
LEGEND
TAP INSPECTION CHAMBER
CWP ( COLD WATER PIPE)
GULLY TRAP WASTE WATER PIPE ( 75MM DIA)
FLOW DIRECTION
SHAFT
M
GT
SUBJECT : ARCHITECTURAL DRAWING AND COMPUTER APPLICATIONSCOURSE:
MALE
SOLID WASTE WATER PIPE ( 100MM DIA)
DOWN
MAN HOLE
ANGLE VALVE
SWIMMING POOL 25X 12
FEMALE
GT
FEMALE
CAFE 10 X10 STORE
B.ARCH
DOWN
FEMALE WATER INLET LAYOUT (SPORTS COMPLEX)
CAFE 10 X10
IC
15 MM DIA
STORE
LEGEND
GT
IC
SUBJECT CODE: A BAR 405
GT
M
TISSUE ROLL @ 600mm HT.
INSPECTION CHAMBER
CAFE 10 X10
GULLY TRAP
TOWEL RAIL @ 1320mm HT.
450
D
TO MAIN SEWER
STACK PIPE
15 MM DIA
400
GROUND DRAINAGE FLOOR PLANDRAINAGE LAYOUT (SPORTS COMPLEX)
EMALE
GT
FLOOR TRAP 120
A
430
GT
700 900
75 mm r.w.p (c.p.v.c) pipe
IC
GEYSER
SEM: V
WASH BASIN AT THE HEIGHT OF 800mm
TAP AT 600mm , DIVERTER AT 1100mm SHOWER AT 2000mm HT.
F 500
Diverter
2400 430/B
1050 850
Angle Valve (Health Faucet)
300
900/B
Angle Valve
550
1500/B
Concealed Stop Cock
1650
200/D
C
SANITARY LAYOUT
G.T
GULLY TRAP
300MM X 300MM
I.C
INSPECTION CHAMBER
600MM X 600MM
I.C.R
INSPECTION CHAMBER (RAINWATER)
600MM X 600MM
W.W.P
WASTE WATER PIPE
75 MM DIAMETER
S.W.P
SOIL WATER PIPE
100 MM DIAMETER
R.W.P
RAIN WATER PIPE
75 MM DIAMETER
AR. KRISHN MATHUR
TAP CONCEALED AT THE HEIGHT OF 600mm
MIRROR AT THE HT. OF 1100mm
SANITARY LAYOUT (RESIDENCE) M
SUBMITTED TO:
200
B
C
1200/D
Shower
500
G
180
IC
B
1650
200mmx 200mm TILES IN FLOORING
450
GT
500/D
Angle Valve (2)
ALL PIPELINES ARE OF CHLORINATED POLYVINYL CHLORIDE
10 mmTHICK WALL FINISH
75 mm w.w.p (p.v.c) pipe
ICR
A
F
D
TILE DROP
COURSE: B.ARCH
CENTRE
1050
10mm THICK TILE
BATHING AREA
B
HEIGHT
Basin Diverter (Center hole mixer)
Hand Shower Faucet
250
FLOOR TRAP
IC
POINTS & FITTINGS
C
350
450
S.NO
INSTITUTE: D CENTRE FOR DESIGN EXCELLENCE, E VIVEKANANDA GLOBAL UNIVERSITY
19mm TILE DROP
20 MM DIA
1900
FLOOR TRAP
STORE
E
NAME: AAKANGSHA ROY
100 mm s.w.p (c.p.v.c) pipe
SOLID WASTE WATER PIPE ( 100MM DIA)
MAN HOLE
ALL MEASUREMENTS ARE IN MILLIMETERES PILLAR COCK
CASCADE W.C
FEMALE
FLOW DIRECTION
M
SEM: V
TAP CONCEALED AT THE HEIGHT OF 600mm
80
WASTE WATER PIPE ( 75MM DIA)
TAEKWONDO/JUDO 15 X 15
ANGLE VALVE
HEALTH FAUCET @ 450mm HT.
900
IC
SHOWER AND TAP
20 MM DIA
IC
WONDO/JUDO 5
TAP CWP ( COLD WATER PIPE)
IC
GT
LEGEND
PILLAR COCK
STACK PIPE
IC
SHOWER AND TAP
20 MM DIA
15 MM DIA
FLOOR TRAP
GT
NAME: AAKANGSHA ROY
DOWN GT
MALE
SUBJECT CODE: BAR 405 LEGEND
15 MM DIA
IC
UP
M
TECHNICAL SWIMMING P 25X 12 DRAWINGS
SUBJECT : ARCHITECTURAL DRAWING AND COMPUTER APPLICATIONS
SWIMMING POOL 25X 12
FEMALE
LADIES TOILET
ASKETBALL 0 X 24
MALE
CHANGING ROOM FOR SWIMMING POOL
GENTS TOILET
SHAFT
20 MM DIA 15 MM DIA
CHANGING ROOM FOR SWIMMING20 MM DIA 15 MM DIA POOL
GENTS TOILET
SHAFT
09
SWIMMING POOL 25X 12
SUBMITTED TO: AR. GAURAV AGRAWAL SUBMITTED BY: AAKANGSHA ROY B.ARCH III SEM CODE VGU
ELECTRICAL DRAWINGS SB4 D
1820
BL : BLANK
PL : PICTURE LIGHT SWITCH
EX : EXHAUST SWITH
1600
1860
1100
540
560
1950
1650
PL3
L25
WL7
WARDR0BE L13
L34
1
GEYSER BOARD
WL11 TL 3
SB3 F
WL13
WL12
L28
L27 700
700
L37
L36
SB1 C
2400
4
SB1 D
1350
5
SB1 E
1350
6
SB1 F
1350
7
SB1 G
1350
8
SB1 H
2400
9
SB2 A
1350
SB2 B
1350
11
SB2 C
600
12
SB2 D
600
13
SB2 E
2400
14
SB2 F
1350
15
SB2 G
1350
2400
SB3 C
600
F3
20
SB3 D
600
WL11
SWITCH
21
SB3 E
1350
CALL BELL SWITCH
22
SB3 F
1350
23
SB3 G
24
SB3 H
2400
25
SB4 A
1350
26
SB4 B
1350
27
SB4 C
1350
28
SB4 D
1350
29
SB4 E
1350
30
SB5 A
1350 1350 1500
33
SB5 D
1350
34
SB5 E
1350
1700
1000
5 6 7
(6) SB 4
SS,1CL,1CL,CAL
(8) SB 5
SS,TV,FE,SS
(2) SB 6
CABLE
(2) SB 7
TV SOCKET
450
HW AC 1
HW AC 1 @ 2100 MM
1050 MM
SS,PL
525 MM
(8) SB 10
G,CL,BL,F,R
1050 MM
(6) SB 11
SS,PL,CL,EX
1050 MM
CL : CEILING LIGHT SWITCH
CAL : CABINET LIGHT SWITCH
FL : FOOT LIGHT SWITCH
G : GEYSER SWITCH
WR : WARDROBE LIGHT SWITCH
BL : BLANK
PL : PICTURE LIGHT SWITCH
EX : EXHAUST SWITH
F4
PL4-PL5
L19-L20-L25
L30-L31
WL15
2
F
L32-L33
L34-L35
F5
L36-L37
CONCEALED AC
ODU
OUT DOOR UNIT CONNECTION / SUPPLY LINE RETURN LINE
(18 MM DIA / 15 MM DIA)
DRAIN LINE
HW AC 2
C. AC @ 2470 MM
FALSE CEILING
SUBMITTED TO: AR. GAURAV AGRAWAL
GEYSER
ASSIGNMENT 1
AC
ODU 3
2W
BUILDING SERVICES III CN. AC 1
SUBMITTED BY: AAKANGSHA ROY
2 WAY CONNECTION
ODU 3 @ 1050 MM
940
ODU 4 ODU 5
WARDR0BE
HW AC 2 @ 2100 MM
F : FAN SWITCH
C. AC @ 2470 MM
ASSIGNMENT 2
TV
(18 MM DIA / 15 MM DIA)
CO : COVE LIGHT SWITCH
SUBMITTED TO: AR. GAURAV AGRAWAL.
L16-L17-L18
(15 MM DIA / 18 MM DIA)
FE : FEATURE LIGHT SWITCH
1
L15
L14 WL9
ELECTRIC WIRE
NOTE R : FAN REGULATOR
L29
G
CN. AC
1530
PICTURE LIGHT
SS : SOCKET AND SWITCH
L27-L28 WL14
HIGH WALL AC
C. AC 2
AS PER TV CABINET
SS, CL , WF, AC
TV
WL12 WL13
HW AC
FOOT LIGHT
(8) SB 8
L24-L25-L26
CASSETTE AC
CEILING LIGHTS
1050 MM
(4) SB 9
L22- L23
WL10
PL3
350
800
FAN
525 MM
C. AC 1
660
4
SS,3CL,1CL,F,R
2150
525 MM
AC
C. AC
1200
1050
1220
(8) SB 3
SS,1CL,PL,CO
1050 MM
400
(6) SB 2
F,3CL,2CL,1CL,FL,WR
G
L22-L23
1350
1000
(6) SB 1
L11
1000
LEGENDS
HEIGHT
L12-L13
WL6 WL7
WL8
SB3 B
SB5 C
PL2
WL4 WL5
F2
AC
19
350
DETAILS
L9-L10
18
SB5 B
L3-L4
TV
5A SWITCH AND SOCKET
B.ARCH SEM VI 19FAP2AR001 CODE, VGU
3280
MODULES
G
L9-L10
LEGEND
ELECTRIC PLAN
N
L8
WL3
2400
32
L1-L2
TV
L6-L7
1350
31
L5
AC
SB3 A
400
ODU 1 ODU 2
3
L6-L7
WL1
WL2
C. AC @ 2470 MM
B.ARCH SEM V 19FAP2AR001 CODE, VGU
ASSIGNMENT 2
F1
SB2 H
ARCHITECTURAL DRAWING AND COMPUTER APPLICATIONS
280
AAKANGSHA ROY
ODU 1 @ 1050 MM BUILDING ODU 2 @ 1800 MM SERVICES II
PL1
600
17
ASSIGNMENT 1
ELECTRICAL LAYOUT ELECTRICAL LAYOUT
SUBMITTED BY:
600
SB1 B
16
SUBMITTED BY: AAKANGSHA ROY
SUBMITTED TO: AR. GAURAV AGRAWAL.
SB1 A
2
SWITCH BOARD LEGEND
SUBMITTED TO: AR. KRISHN MATHUR
1980
1000
L26
DESCRIPTION
1
10
TV CABLE
F : FAN SWITCH
2
TELEPHONE POINT WITH INTERNET CABLE
920
580
700
FE : FEATURE LIGHT SWITCH
700
300
SB3 G
1220 MM FAN POINT
5/15A SWITCH AND SOCKET
L35
SB3 D
500
F TL
1800
F5
800
WL14
2 WAY CONNECTION
L12
WARDROBE LIGHT POINT
340
G
1600
720
F3
SB2 G
SB2 F
700
L
855
700
WL10
L24
WL6
CEILING LIGHT POINT
1300
G : GEYSER SWITCH
WR : WARDROBE LIGHT SWITCH
L
CALL BELL
SB3 C
SB3 H
2W
WL
WALL LIGHT POINT
850
WL8
131
FL : FOOT LIGHT SWITCH
L33
L32
660
930
CAL : CABINET LIGHT SWITCH
850
SB5 E
L23
1970
SB3 E
320
R : FAN REGULATOR
1720
160
L29
G
840
300
CL : CEILING LIGHT SWITCH
1200 590
730
SB4B WL9
318
600
SS : SOCKET AND SWITCH
240
1080 1900
AC
SB2 D
PL2
840
SB3 B
L22
PICTURE LIGHT SB2 C TL 2
720
720 1140
GEYSER 990 L11
SB2 H
WL5
CO : COVE LIGHT SWITCH
2W
1300 790
1050 MM
PICTURE LIGHT POINT
DISTRIBUTION BOARD
SB5 D
PL5
2
400
358
160
250
2W
NOTE
SS,PL,CL,EX
L21
5
FALSE CEILING
G
PL
SWITCH BOARD DETAILED LEGEND SL NO. SWITCH HEIGHT BOARD NO. FROM FFL (MM)
EXHAUST FAN POINT
470
5 6 7
1050 MM
720
SB3 A
SB2 E
1440
G,CL,BL,F,R
WL4 800
BEDROOM
F2
310
ELECTRIC WIRE
1000
770
560L4
525 MM
350
380
(6) SB 11
SS,PL
SB4 E PL4
L15
L10
450
(8) SB 10
1050 MM
SWITCH BOARD
850
980
(4) SB 9
SS, CL , WF, AC
550
580
4
L9
TV SOCKET
1700
(8) SB 8
3
410
SB1 E
SB2 A 540
450
450
775 560 L3
FOOT LIGHT 1720
SB
SB5 A
1000
560
560
775
CABLESB2 B
(2) SB 7
9
8
190
(2) SB 6
10
AS PER TV CABINET
L31
1870
1870
1850
SB1 D
410
(8) SB 5
L20
L19
L30
250
SB4 A
580
SS,TV,FE,SS SB1 C 1000
CEILING LIGHTS L7
WL15
2100
580
1050 MM
480
800
G
440
SS,1CL,1CL,CAL L6
L2
(6) SB 4
SB1 H
F4
610
525 MM
560
770
SS,3CL,1CL,F,R
L18
L14
WI FI
(8) SB 3
L17
SB5 C SB5 B
560
L8
FAN
1460
830
1870
1880
HARD DRIVE
525F1MM
910
840
STORE
SS,1CL,PL,CO
SB1 G
SB1 F
200
1050 MM
(6) SB 2
TL 4
SB4 C
L16
193
F,3CL,2CL,1CL,FL,WR
LEGENDS
L5
570
(6) SB 1
680
HEIGHT
480
1130
DETAILS
WL3
250
11
L1
WL2
440
420
775
MODULES
1120
SB1 B1000
1710
TOILET
N
PL1
SB1 A WL1 TL 1
ELECTRICAL LEGEND
190
870
320
SUBMITTED BY: AAKANGSHA ROY BUILDING SERVICES II B.ARCH SEM V 19FAP2AR001 CODE, VGU
HVAC LAYOUT HVAC LAYOUT
ODU 4 @ 1050 MM ODU 5 @ 1800 MM
B.ARCH SEM VI 19FAP2AR001 CODE, VGU
43
SITTING
WORKSPACE CUBICLES CABIN SITTING
CABIN
RECEPTION AND WAITING
CONTROL:RECEPTION
SERVER ROOM
BIOMETRIC
LPG SENSOR
FEMALE WASHROOM
HEAD CABIN
ENTRY
SERVICE PLAN 1 CONFERENCE ROOM
SITTING
MALE CUBICLE WASHROOM MALE WASHROOM
RECEPTION AND WAITING
RECEPTION AND RECEPTION WAITING AND CABIN WAITING
LEGEND
HEAD CABIN
FEMALE WASHROOM FEMALE WASHROOM
E.P.A.B.X
RECEPTION AND WAITING
SERVER ROOM
RECEPTION AND WAITING
CABIN
CONTROL:RECEPTION
HEAD CABIN
CUBICLE
CABIN
RECEPTION AND WAITING
SITTING
FEMALE SITTING WASHROOM
E.P.A.B.X CUBICLE
CABIN RECEPTION AND WAITING
SERVER ROOM
CABIN
LPG SENSOR
FEMALE WASHROOM
65 MM BALL VALVE
RECEPTION AND WAITING
WORKSPACE CUBICLES
HOSE REEL SLEEVE
CABIN
PANTRY
CABIN MEETING/
RECEPTION AND
CUBICLE
SERVICE PLAN 3
MEETING/ CONFERENCE ROOM
CONTROL:HEAD CABIN
FEMALE WASHROOM
WORKSPACE CUBICLES SITTING
CABIN
LEGEND
CABIN
PANTRY
RECEPTION AND WAITING
CABIN
smoke sensor SENSOR- AC OCCUPATION
BUILDING AUTOMAT OCCUPATION SENSOR - LIGHT
VDP
FEMALE WASHROOM
AC
LEGEND building services ii AC
GLASS BREAK SENSOR
CUBICLE
FIRE - ALARM SITTING
WORKSPACE CUBICLES
MALE WASHROOMSITTING
smoke sensor
SITTING PANTRY
CABIN
CABIN
VDP
GLASS BREAK SENSOR
VDP
CABIN
CABIN
PANTRY
WORKSPACE CUBICLES
WORKSPACE CUBICLES
SITTING
CABIN
MALE WASHROOM FEMALE WASHROOM
SERVICE PLAN 5
HEAD CABIN
ENTRY
CABIN SITTING
CUBICLE
assignment 3
WORKSPACE CUBICLES
CABIN
FEMALE WASHROOM
RECEPTION AND WAITING
HEAD CABIN
LEGEND
MALE WASHROOM
ELECTRIC DOOR LOCK
RECEPTION AND WAITING
MEETING/ CONFERENCE ROOM
WORKSPACE CUBICLES
CUBICLE
ENTRY
VDP
OCCUPATION FIRE - ALARMSENSOR - LIGHT
SITTING
SERVICE PLAN 5
ROOM
LEGEND
MALE WASHROOM
ENTRY
MEETING/ CONFERENCE
ROOM RECEPTION CABIN AND MEETING/ WAITING CONFERENCE
MALE WASHROOM
HEAD CABIN
OCCUPATION SENSOR- AC
CUBICLE SERVICE PLAN 3
HEAD CABIN
FEMALE WASHROOM
PANTRY
SERVICE PLAN 5
SERVICE PLAN 3
SERVICE PLAN 3
FEMALE WASHROOM
PANTRY
CABIN
PANTRY
PANTRY
WORKSPACE CUBICLES
25 MM DIA DRAIN PIPE
CABIN
smoke sensor
SITTING
HEAD ENTRY CABIN ELECTRIC DOOR LOCK
FEMALE WASHROOM
FIRE FIGHTING SYSTEM LAYOUT (RESIDENCE)
MALE WASHROOM
SERVICE PLAN 5
RECEPTION AND WAITING
FIRST FLOOR FIRE FIGHTING SYSTEM LAYOUT
PANTRY
CUBICLE
RECEPTION AND WAITING
CONTROL:HEAD CABIN
HEAD CABIN
FIRE - ALARM
SITTING
WORKSPACE CUBICLES
CABIN
LEGEND
ENTRY
MEETING/ CONFERENCE ROOM
B.ARCH SEM VI LEGEND 19FAP2AR001 CODE, VGU CCTV - DSPLAY
ENTRY
CUBICLE
FEMALE WASHROOM
WORKSPACE CABIN CUBICLES
SUBMITTED BY: MEETING/ CONFERENCE AAKANGSHA ROY CABIN ROOM
MALE WASHROOM
FEMALE WASHROOM
65 MM BALL VALVE
WASHROOM
smoke sensor
smoke sensor
CABIN
ENTRY
RECEPTION AND WAITING
PANTRY
SERVICE PLAN 2
CABIN
CCTV - DSPLAY
FEMALE PLAN 3 SERVICE
HEAD CABIN
HEAD SUBMITTED TO: CABIN AR. GAURAV AGRAWAL
CUBICLE
MALE WASHROOM
FIRE - ALARM
FIRE - ALARM
MALE WASHROOM
RECEPTION AND WAITING
RECEPTION AND WAITING
HEAD CABIN
CONTROL:HEAD CABIN
PANTRY
MALE WASHROOM
CUBICLE
LEGEND CCTV - DSPLAY
LEGEND
ENTRY
CUBICLE
CABIN
SERVICE PLAN 1
LEGEND
PANTRY
ROOM
WAITING CABIN
BUILDING SERVICES
LEGEND
SITTING
WORKSPACE CUBICLES
ENTRYCONFERENCE
ESCAPE ROUTE
ASSIGNMENT 3
FEMALE WASHROOM
SITTING
CABIN
65 MM BALL VALVE
PANTRY
FEMALE WASHROOM
WORKSPACE CUBICLES
ENTRY CABIN
MEETING/ CONFERENCE ROOM
CABIN
MALE WASHROOM
SPEAKERS
SITTING
HEAD CABIN
MEETING/ CONFERENCE ROOM
CUBICLE
SERVICE PLAN 2SERVICE PLAN 3
HEAD CABIN
CABIN
WORKSPACE CUBICLES
PANTRYMALE WASHROOM
RECEPTION AND WAITING
CABIN
BIOMETRIC
SITTING
25 MM DIA DRAIN PIPE
CONTROL:HEAD CABIN
CUBICLE
ENTRY
CABIN
25 MM BALL VALVE
CCTV - DSPLAY LEGEND
SITTING
MEETING/ CONFERENCE ROOM
CONTROL:RECEPTION
BIOMETRIC
HEAD CABIN
65 MM BALL VALVE
ENTRY
CABIN
MALE WASHROOM
LEGEND
WORKSPACE CUBICLES MEETING/ CONFERENCE ROOM
25 MM DIA DRAIN PIPE HEAD
ENTRY
CONTROL:HEAD CABIN
FEMALE WASHROOM
WORKSPACE
LEGEND
25 MM DIA DRAIN PIPE
CCTV - DSPLAY SERVICE PLAN 3
MALE WASHROOM
CONTROL:HEAD CABIN
CUBICLES HEAD CABIN
65 MM DIA PIPE CABIN
CABIN
MALE WASHROOM
RECEPTION AND WAITING
CUBICLE
50 MM DIA PIPE
WORKSPACE CUBICLES
LEGEND
CCTV - DSPLAY
PANTRY
CUBICLE
ENTRY
LEGEND
FEMALE WASHROOM
ENTRY
HEAD 40 MM DIA PIPE CABIN
HEAD CABIN
SITTING
CABIN MEETING/ CONFERENCE ROOM
MEETING/ CONFERENCE ROOM
SERVICE PLAN 1
MALE WASHROOM
SERVICE PLAN 1 RECEPTION AND SERVICE PLAN 3 WAITING
FIRE EXTINGUISHER 25 MM DIA PIPE
MEETING/ CONFERENCE ROOM
LEGEND SPEAKERS
WORKSPACE CUBICLES
LPG SENSOR
PANTRY
SERVICE PLAN 1PANTRY
ENTRY
CONFERENCE ROOM
CONTROL:HEAD CABIN
MALE WASHROOM
PANTRY
80 MM RISER PIPE CABIN MEETING/
BIOMETRIC
65 MM BALL VALVE
CCTV - DSPLAY
CUBICLE
SITTING
CABIN
BIOMETRIC
FEMALE WASHROOM
PANTRY
SITTING
CABIN
DOWN PIPE
MALE WASHROOM
LEGEND ENTRY
ROOM
FEMALE WASHROOM
ENTRY
CUBICLE
LPG SENSOR
LPG SENSOR
SITTING CABIN WORKSPACE CUBICLES WORKSPACE MEETING/ CUBICLES CONFERENCE
CABIN
25 MM DIA DRAIN PIPE
PANTRY
FEMALE WASHROOM
WORKSPACE CUBICLES
HOOTER/ CALL POINT
LEGEND
CONTROL:RECEPTION
CONTROL:HEAD CABIN
BIOMETRIC BIOMETRIC
SERVICE PLAN 1
BIOMETRIC
HEAD CABIN
SMOKE/ FIRE SENSOR
SPRINKLER
CONTROL:RECEPTION
E.P.A.B.X
CCTV - DSPLAY
MALE WASHROOM
SERVER ROOM
SERVER ROOM
BIOMETRIC
HEAD CABIN
E.P.A.B.X
ENTRY
CUBICLE
CABIN
CUBICLE
25 MM DIA DRAIN PIPE
LEGEND LEGEND LEGEND
WORKSPACE CUBICLES
ENTRYMEETING/
ROOM
MEETING/ CONFERENCE ROOM
MALE WASHROOM
BIOMETRIC
MEETING/ CONFERENCE MEETING/ ROOM CONFERENCE
65 MM BALL VALVE
CUBICLE
PANTRY SERVICE PLAN 1
CABIN
MEETING/ CONFERENCE ROOM
E.P.A.B.X
PANTRY
AUTOMATION AND SECURITY
CABIN
FIRE FIGHTING SYSTEM
LEGEND
ENTRY
MEETING/ CONFERENCE ROOM
PANTRY
BUILDING AUTOM BUILDING AUTOMATI
SERVICE PLAN 4
HEAD CABIN
3 assignment 3 assignmentSERVICE PLAN 4 WORKSPACE CUBICLES
building servicesiiii building services LEGEND
N
WORKING AND CONSTRUCTION DRAWINGS 120000
8750
LEVEL +75
C'
69000
1041
1259
2368
MALE 691
691
691
691
691
691
3824 691
FEMALE
1567 1013
D6
3400
D6
1023
691
1023
1033
691
691
691
691
691
691
691
1353
9750
1490
1013
1762
D6
D6
D6
D6
228 416
1075
378
1075
D6
D6
1425
8465
1407
D6
D6
361
730
474
477
325
1072
595
2652 3963
6
5550
1240
492
5534
9100
MALE D2
467
D6
1525
2680
D2
1750 2500
D2
2616
2813
535
D6
D6
D6 D6
D2
D2
1
691
691
691
3 2
691
691
1110
1110
2086
1110
691
1040
691 780
D6
DISABLED
1567 2200
691
691
620
1149
D6 1490
D2
2200 16800
V1
691
1490
300
4580
237
V1281 V1
691
564
3294
2704
1
7
4 3
2
6 5
11
12
587
21 22
16
19
18
17
8
20
13 14 15 10 9
LIFTS AND STAIRCASE
5300
SHAFT
691
691
456
D4CHANGING ROOM WITH LOCKERS
3750
3250
V1253 V1
691
6875 1490
UP
2000
W2 4987
560
V1303 V1
814
809
317
1362
1462
1625
D6
LADIES TOILET
D4
677
1212
D6 464
D6188 660
2569
1224
D6 464
D6
1272
1514
1277
D6 657
665
2750
BASKETBALL
2166
1000
1075
1062
V1
239 404
1413
D2
1103
6775
1100
1776
1013
D5
1567
1000
D6 1625
1023
432
CHANGING ROOM FOR D2 SWIMMING POOL D2
D6
484
325
D6
1023
177
404
D6
863
D6
677
203
D6
D2
4500
4850
GENTS TOILET
414
5100
5100
5161
SHAFT
9550
1110
5586
1200
2766
1964
D6
24000
254
211
2400
1470
2791
2313
2550
W1 4061
1653
2900
W1
2129
498
W1 1821
809
W1 1736
445
442
484
D6
D6
D6
D6
1100
1100
1100
353
342
D6
D6
D6
7527
1250
1100
4859
CAFE
3311
1
8
300
60000
4 3
2
1411 3139 791 600
12
D6
V2
D6
D6
D6
D6
V2
D6
D6
D6
D6
W9
2 1
3292
1438
V3
762
3194
V3
4400
LEVEL +135
5000
391
7 6 5 4 3
LEVEL -345
D6
11 10 9
NO.S : 22
V2
D6
686
14
D6
13
RISER : 150MM
W6
V2
D6
5791
15
NO.S : 21
370
D6
19 18 17 16
709
2550
V2
D6 D6
679
7802
1
7
11
2
13 12
4 3
6 5
8
10 9
14
15
19
18 17 16
21
20
17525
D6
21 20
TREAD : 300MM
TAEKWONDO/JUDO
6075
9400
7750
W5
RISER : 150MM
D2 FEMALE
D6
D2
3730 4425
4500
3615
4875
1464
THREAD : 300MM
5
D2
2905
3459
LEVEL +135
NO.S : 21
D2
2007
NO.S : 22
D1
1538
D1
7952
1250
RISER : 150MM
1694
2678
1
2
7
4 3
5083
1250
21 22
16
19
18
17
20
TREAD : 300MM
5013
LEVEL -215
C
1100
9550
2670
5264
8550
6 5
160
571
8750
13 14 15
12
D3
11
3387 138
10 9
W4
329
DOWN
NO.S : 21
8
W3
4425
NO.S : 22
1100
39000
1985
233 1050 9550 5300
16150
W8
73
IN C V
1500
769
W7
104
OPEN AMPHETHEATRE
678
110
19250
20000
LEVEL +45
WORKING DRAWING (SPORTS COMPLEX)
N
GROUND FLOOR PLAN
SUBMITTED TO: AR. GAURAV AGRAWAL
ASSIGNMENT 2
3.
C2 C3
WIDTH
450
600
F3
600
450 300
750 600
C2 540
C3
C2
PB2
LVL -2500
1.
5100
PB13
C2
PB2
PB3
9000 C2
PB4
9550
3400
6620 C2
PB12
C3
F2
2. 3.
2000
8325 C1
SEM: V
PB11
8550
PB11
PB11
8550
5250
PB2
PB3
9550
C3
PB15
C3
8550
PB2
2.
WIDTH 3600
F2
3450
3750
F3
3300
3600
PB12
C3
PB6
PB11
6620
C3
17400
PB7
3.
REGULAR FOOTING
SUBJ ARCH COM
SUBJ BAR
C3
PB6
PB12 C3
PB5
PB13
9550 C3
PB6
3400
PB13
9100
9100
9100
PB9
PB6
PB11
PB11
C1
1.
LENGTH 3450
F1
3400 C3
9400
PB10
PB10
600
5001
LVL -3000 C2
PB12
PB6
PB15 C3
9550
9000 C3
C3
PB4
9550 C3
NAM AAK
DEPTH 3000
2070
C1
F1
SUBMITTED TO:
4. 5.
PB1
PB15
SEM
PB3
HEIGHT 600
NO. BEAMS
3000
C2
F2 1980
C3
F3
HEIGHT
8.
PB8
5100
450
600
450
600
9.
PB9
16800
450
600
PB3
5250
450
600
10.
6620
450
600
PB5
9000
450
450
6.
PB6
9550
450
450
7.
PB7
17400
450
450
AR. KRISHN MATHUR
WIDTH
8550
2070
3000
LENGTH
PB2
PB4
COU B.AR
PB6
C3
5256
PB11
C3
PB6
PB5
PLINTH BEAM LAYOUT COMPLEX) PLINTH(SPORTS BEAM PLAN
NO. FOOTING
C3
9550 C3
9400
9400
COURSE: B.ARCH
INSTITUTE: CENTRE FOR DESIGN EXCELLENCE, WIDTH NO. BEAMS LENGTH VIVEKANANDA GLOBAL UNIVERSITY 8325 450
810
810
C2
5250
8550
8550
C2
10000
G
4800
C3
600
C1
9550
PB6 PB12
PB6
16800
NAME: 8325 AAKANGSHA ROY PB1
5000
600
600
600
5350
600
600
600
3600
LENGTH
C3
PB6 PB12
C3
600
F3
5100
4000
16800
9700
600 600
F
5200 C3
600
C3
PB5
8800
400
8800
600
5200 600
600
4800
600
4000
4900 600
600
600
600
5200 600
600
1401
600
5350
C2
PB14
9550
9550
4500 600
4860 600 600
4800
600
5001
F3 10214
F3
600
2250
2.
C1
C3
F3
C3
600
F3
2160
1.
7061
600
4875
C2
PB9
EXCAVATIONEXCAVATION PLAN (SPORTS PLAN COMPLEX)
SUBMITTED BY: AAKANGSHA ROY B.ARCH SEM VI 19FAP2AR001 CODE, VGU
NO. COLUMN
F3
5350 600
4500 600
C2
C3
PB1
C3
F3
C2
PB14
9550
PB10
9400
450
600
11.
PB11
9400
300
450
12.
PB12
3400
300
450
13.
PB13
9100
300
450
14.
PB14
5100
300
450
15.
PB15
4400
300
450
INSTIT CENT VIVEK
450
300 450
4200
4500 600
C3
F3
C3
5350 600
C2
PB6
600
OVERHEAD
1500
F3
PB14
450
450
PIT
900
BUILDING SERVICES III
F3
1200
CLEAR OPENING
600
1401
1100
600
1675
600
C3
2414
600
C3
1080
1600
4807
600
F3
C3
4500
3761
5714
9801
F3
1350
408
F2
600
C3
1080
KGS
6
10127
600
600
600
600
CAR INSIDE WIDTH DEPTH
F2
11561
4425
600
4800
F1
600
600
PERSON
LIFT SHAFT WIDTH DEPTH
F2
C3
5126
600
4118
600
2000
C1
4802
F1
4802
600
600
600
4350
600
F3 400
600
C2
4800
3611
C2
5100
5700
600
600
4900
600
600
600
F3
600
600
2264
C2
4500
600
600
C1
4950
F2
600
600
5126
PLAN
5000
4350
600
3146
600
3500
10000
A'
600
300 850 100
3500
2100 230
LIFT DETAIL
E
600
C3
600
F2
C2
600
4118
600
1500 230
SECTION
600
600
4950
4950
C2
ENTRY
F2
GLOAD
600
600
600
LIFT
C2
F
600
600
600
230
17425
PB8 9000
C2
C3
PB6
D
600
C3
8800
350
4650
5126
BASEMENT
COUNTER WEIGHT
600
4500 600
600
C3
400
900
600
600
600
1570
350
4650
4650
PLINTH
4500 600
600
C3
MACHINE ROOM
GROUND FLOOR
F3
600
1200 230
E
4650 600
C4
4000
3000
D 1ST, 2ND, 3RD, 4TH FLOOR
800
1675
350
1100
C3
PB5
3400
4500
PB8
9550
C3
C1
PB4
ASSIG
9850
9550
9000
C1
PB3
SUBJECT CODE: BAR 405
C3
5223
F3
600
4900
12750
12750
C2
12750
230
12750
A
1600
460
C1
12750
9700
5TH AND TERRACE / LAST FLOOR
LIFT CAR
2023
C3
5350
F3
6620
C1
PB2
9800
F3
600
C3
C1
9400
9
400
F3
400
600
600
C3
400
F3
14500
2023
C3
7000
5250
8550
8550
PB2
ARCHITECTURAL DRAWING AND C COMPUTER APPLICATIONS
F3
14500
2023
4807
600
600
600
600
600
C3
F2
600
F3
14500
2023
10574
2023
2411
F2
600
600
600
600
600
600
600
10574
2023
600
F2
C2
B SUBJECT :
C3
5800
9000
C1
PB1
600
600
C3
F3
8325 C1
4500 600
600
C3
F1
C2
600
600
4350
F2
600
C
F1
A
9850 4500
600
600
C1
2264
C2
4350
9800 4500
600
600
C1
F1
C2
F2
600
4000
F2
C2
4118
600
C1
F1
2023
2023
10574
5700
2100 1200
4200 3000
C2
9400 4650
600
C1
F1
7000
10363 600
600
C1
F1
B
600
600
600
600
600
2100
600
600
C1
10574
450
600
600
A
900
4650
4650
4650
5800
9000
9000
10574
8700
230
9000
5100
8700
8
3400
ASSIGNMENT 1.2
7
6
5100
9
5
4
3400
8
3
9400
6
2
9400
4
1
4400
3
7
4400
2
5
4400
1
45 SUBM
AR. K
10
MISCELLANEOUS
PHOTOSHOP RENDERS
47
SMALL SCALE MODELS
49
Email: aakangsharoy2001@gmail.com Phone: 7896689868 Social: @parchfect_hunt