Comflor 60 product guide june 2014

Page 17

ComFlor 60/80 Construction details Side Cantilever with Stub Bracket

Typical Edge with Plate

T Edge Trim

T

CF 60/80 Floor Decking

Steel stud

Beam centres

Edge trim

Restraint strap

CF 60/80 Floor Decking 50 mm min

Steel stub as designed by the engineer

Universal Beam

Typical Wall End Detail

100mm wall shown here

Universal Beam

Typical Wall Side Detail Wall outer dimension

Edge trim to align with edge of wall

Closure plate in 2mm flat steel strip to make up ‘out of module’ floor width. Available in 150 and 240mm widths.

Wall outer dimension

CF 60/80 Floor Decking requires 50mm minimum side bearing onto masonry.

CF 60/80 Floor Decking requires 70mm minimum end bearing onto masonry.

Edge trim to align with edge of wall 100mm wall shown here