Straumann USA Product Catalog 2014

Page 46

Standard Plus Implants Ø 4.8 mm Regular Neck Ø 4.8 mm

Art. No.

Article

Dimensions

Material

Price $ SLActive / SLA

SLActive ®

SLA®

033.250S*

043.939S*

Standard Plus implant

SLActive/SLA   6.0 mm

titanium

425 / 355

033.251S

043.940S

Standard Plus implant

SLActive/SLA   8.0 mm

titanium

425 / 355

033.252S

043.941S

Standard Plus implant

SLActive/SLA 10.0 mm

titanium

425 / 355

033.253S

043.942S

Standard Plus implant

SLActive/SLA 12.0 mm

titanium

425 / 355

033.254S

043.943S

Standard Plus implant

SLActive/SLA 14.0 mm

titanium

425 / 355

SURGERY

Straumann Standard Plus Implants - Guided 033.251G

Standard Plus guided implant

SLActive 8.0 mm

titanium

450

033.252G

Standard Plus guided implant

SLActive 10.0 mm

titanium

450

033.253G

Standard Plus guided implant

SLActive 12.0 mm

titanium

450

048.371S

RN Closure cap, small

height 0 mm

titanium

60

048.371V4†

RN Closure caps, small (pack of 4)

height 0 mm

titanium

160

048.373S

RN Closure cap, large,

height 1.5 mm

titanium

60

048.373V4†

RN Closure caps, large, (pack of 4)

height 1.5 mm

titanium

160

048.028S

RN Healing cap, labial

height 2.0 mm

titanium

60

048.029S

RN Healing cap, labial

height 3.5 mm

titanium

60

048.033S

RN Healing cap

height 2.0 mm

titanium

60

048.034S

RN Healing cap

height 3.0 mm

titanium

60

048.037S

RN Healing cap

height 4.5 mm

titanium

60

Closure caps and healing caps

S = Sterile † = Sterile

Note Straumann guided implants can be inserted fully guided through the Straumann sleeves with an internal diameter of Ø 5.0 mm. Please refer to the brochure “Basic Information on Straumann Guided Surgery” (NAMLIT 1006). 4.8 mm 1.8 mm

SLActive®/SLA®

Standard Plus implants Ø 4.8 mm RN have the same applications as Standard implants Ø 4.8 mm RN (see page 21). 4.8 mm 4.2 mm

30

Applications The smooth neck section of Standard Plus titanium implants is 1.0 mm shorter than with Standard implants. Standard Plus implants are particularly suitable for use in the esthetic region. The implant shoulder should be positioned about 1.0 mm apical to the cemento-enamel junction (CEJ) of the contralateral tooth or 2.0 mm subgingival of the prospective gingival margin.

*Application of SLActive ®/SLA® 6.0 mm Due to the reduced surface area for anchorage in the bone, these implants are to be used solely for the following situations: – A s an additional implant together with longer implants to support implant-borne reconstructions. – A s an auxiliary implant for implant-borne bar constructions supporting full dentures in a seriously atrophied mandible.


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.