Standard Plus Implants Ø 4.8 mm Regular Neck Ø 4.8 mm
Art. No.
Article
Dimensions
Material
Price $ SLActive / SLA
SLActive ®
SLA®
033.250S*
043.939S*
Standard Plus implant
SLActive/SLA 6.0 mm
titanium
425 / 355
033.251S
043.940S
Standard Plus implant
SLActive/SLA 8.0 mm
titanium
425 / 355
033.252S
043.941S
Standard Plus implant
SLActive/SLA 10.0 mm
titanium
425 / 355
033.253S
043.942S
Standard Plus implant
SLActive/SLA 12.0 mm
titanium
425 / 355
033.254S
043.943S
Standard Plus implant
SLActive/SLA 14.0 mm
titanium
425 / 355
SURGERY
Straumann Standard Plus Implants - Guided 033.251G
Standard Plus guided implant
SLActive 8.0 mm
titanium
450
033.252G
Standard Plus guided implant
SLActive 10.0 mm
titanium
450
033.253G
Standard Plus guided implant
SLActive 12.0 mm
titanium
450
048.371S
RN Closure cap, small
height 0 mm
titanium
60
048.371V4†
RN Closure caps, small (pack of 4)
height 0 mm
titanium
160
048.373S
RN Closure cap, large,
height 1.5 mm
titanium
60
048.373V4†
RN Closure caps, large, (pack of 4)
height 1.5 mm
titanium
160
048.028S
RN Healing cap, labial
height 2.0 mm
titanium
60
048.029S
RN Healing cap, labial
height 3.5 mm
titanium
60
048.033S
RN Healing cap
height 2.0 mm
titanium
60
048.034S
RN Healing cap
height 3.0 mm
titanium
60
048.037S
RN Healing cap
height 4.5 mm
titanium
60
Closure caps and healing caps
S = Sterile † = Sterile
Note Straumann guided implants can be inserted fully guided through the Straumann sleeves with an internal diameter of Ø 5.0 mm. Please refer to the brochure “Basic Information on Straumann Guided Surgery” (NAMLIT 1006). 4.8 mm 1.8 mm
SLActive®/SLA®
Standard Plus implants Ø 4.8 mm RN have the same applications as Standard implants Ø 4.8 mm RN (see page 21). 4.8 mm 4.2 mm
30
Applications The smooth neck section of Standard Plus titanium implants is 1.0 mm shorter than with Standard implants. Standard Plus implants are particularly suitable for use in the esthetic region. The implant shoulder should be positioned about 1.0 mm apical to the cemento-enamel junction (CEJ) of the contralateral tooth or 2.0 mm subgingival of the prospective gingival margin.
*Application of SLActive ®/SLA® 6.0 mm Due to the reduced surface area for anchorage in the bone, these implants are to be used solely for the following situations: – A s an additional implant together with longer implants to support implant-borne reconstructions. – A s an auxiliary implant for implant-borne bar constructions supporting full dentures in a seriously atrophied mandible.