May 2016 Advertiser.

Page 12

M ACdverti$er

Th e

omponent

anufacturing

Don’t Forget! You Saw it in the

Adverti$er

May 1st, 2016 #09202 Page #12 SAWS

Simultaneous Loading on Hurricane Ties By Kelly Sias, P.E, Simpson Strong-Tie

“Structures are connections held together by members” (Hardy Cross) Take a quick look at a truss design drawing, and you will see a reaction summary that specifies the downward reaction, uplift and a horizontal reaction (if applicable) at each bearing location. Some people are tempted to look only at the uplift reaction, go to a catalog or web app, and find the lowest-cost hurricane tie with a capacity that meets or barely exceeds the uplift reaction. However, if uplift was the only loading that needed to be resisted by a hurricane tie, why would we publish all those F1 and F2 allowable loads in our catalog? Of course, many of you know that those F1 and F2 allowable loads are used to resist the lateral loads acting on the end and side walls of the building, which are in addition to the uplift forces. Therefore, it is not adequate to select a hurricane tie based on uplift reactions alone. Where does one get the lateral loads parallel and perpendicular to the plate which must be resisted by the truss-to-wall connection? Definitely not from the truss design drawing! Unless otherwise noted, the horizontal reaction on a truss design should not be confused with a lateral reaction due to the wind acting on the walls – it is simply a horizontal reaction due to the wind load (or a drag load) being applied to the truss profile. It is also important to note that any truss-to-wall connection specified on a truss design drawing was most likely selected based on the uplift reaction alone. There may even be a note that says the connection is for “uplift only” and does not consider lateral loads. In this case, unless additional consideration is made for the lateral loads, the use of that connector alone would be inadequate. Say, for example, that the uplift and lateral/shear load requirements for a truss-to-wall connection are as follows: Uplift = 795 lb.; Shear (parallel-to-wall) = 185 lb. (F1); Lateral (perp-to-wall) = 135 lb. (F2). Based on those demand loads, will an H10A work?

2000 Alpine AutoMill RS Component Saw Alpine AutoMill RS model 344, five-blade, computerized component saw. From the OEM literature: sets up in 2 to 19 seconds, using a touch screen for ease of operation. Five-head automated component saw works in semi-automated control via touchscreen input. It has 19 axes of automated movement, diagnostics, auto management reporting. The RS cuts from 13" to 20' long material in size range from 2x3 through 2x12, and includes [3] 18", [1] 20" and [1] 32" blades with air brakes, pc with swingarm cabinet and scrap conveyor under saw. 480v/60Hz/3Ph power. $31,249 FOB QC Wood Truss Systems 765-751-9990 www.woodtrusssystems.com

1997 Timbermill 620 Pro SSD Timbermill 620 Pro single-sided digital, model 6-20 Pro SSD. Six heads cuts lumber from 2x3 through 2x12, 4x2 lengths from 13” to 20’ including four-angle floor truss webs from 19". "Pro" model features faster angulation movements and faster carriage speeds with soft-start technology and powered movements with single-side setup and digital readouts. Includes set of spare blades, drag-chain waste conveyor with incline, and all available spare parts. 480V 3ph. $25,990 NOW $19,900 FOB IA Wood Truss Systems 765-751-9990 www.woodtrusssystems.com

An initial look at the H10A’s allowable loads suggests it might be adequate. However, when these loads are entered into the Connector-Selector, no H10A solution is found. Why? Because Connector-Selector is evaluating the connector for simultaneous loading in more than one direction using a traditional linear interaction equation approach as specified in our catalog. If the shear and lateral forces were to be resisted by another means, such that the H10A only had to resist the 795 lb. of uplift, then it would be an adequate connector for the job. For example, the F1 load might be resisted with blocking and RBC clips, and the F2 loads might be resisted with toe-nails that are used to attach the truss to the wall prior to the installation of the H10A connectors. However, if all three loads need to be resisted by the same connector, then the H10A is not adequate according to the linear interaction equation. Simultaneous Loading on Hurricane Ties continued on page 18

PHONE: 800-289-5627

Read/Subscribe online at www.componentadvertiser.com

MiTek Combi Set Web Saw Four Blades Cut Lengths from 2' to 16'. Waste & Incline Conveyor. Extra Set of Blades. 220/440 Volt - 3 Phase. $13,000 FOB MO. Wasserman & Associates 800-382-0329 www.wasserman-associates.com FAX: 800-524-4982


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.