July 10, 2019 Board Packet

Page 1

Board Workshop and Regular Meeting of the Capitol Region Watershed District (CRWD) Board of Managers, for Wednesday, July 10, 2019 5:00 p.m. (Workshop) and 6:00 p.m. (Regular Meeting) at the office of the CRWD, 595 Aldine Street, St. Paul, Minnesota. WORKSHOP AGENDA (5:00 PM) I. II. III.

I.

Materials enclosed

Call to Order of Board Workshop Ford Site Redevelopment Adjourn Board Workshop REGULAR MEETING AGENDA (6:00 PM) Call to Order of Regular Meeting (President Joe Collins) A) Attendance B) Review, Amendments, and Approval of the Agenda

II.

Public Comment – For Items not on the Agenda (Please observe a limit of three minutes per person.)

III.

Permit Applications and Program Updates (Permit Process: 1) Staff Review/Recommendation, 2) Applicant Response, 3) Public Comment, and 4) Board Discussion and Action.)

A) B) C)

08-016 Payne Ave – Closure (Hosch) 19-015 Waterford Bay (Hosch) 19-017 Urban Academy (Hosch)

IV.

Special Reports – No Special Reports

V.

Action Items A) AR: Approve Minutes of the June 19, 2019 Regular Meeting (Sylvander) B) AR: Approve Contract for Como Lake Alum Plans and Specifications (Belden) C) AR: Approve Stewardship Grant Calculator Update (Novak) D) AR: Approve Springboard for the Arts Special Grant (Zwonitzer

VI.

Unfinished Business A) 2020 Budget Update (Doneux) B) Building Update (Doneux)

VII.

General Information A) Administrator’s Report B) Board of Manager’s Updates

VIII. Next Meetings A) Wednesday, July 17, 2019 CAC Tour B) Wednesday, July 24, 2019 Board Meeting

Our mission is to protect, manage and improve the water resources of Capitol Region Watershed District


IX.

Adjournment

Our mission is to protect, manage and improve the water resources of Capitol Region Watershed District


July 10, 2019 III. Permit Applications A. Permit Close Out (Hosch) DATE: TO: FROM: RE:

July 1, 2019 CRWD Board of Managers Elizabeth Hosch Permit Closeout

Background Construction activity is complete for permit #08-016, Payne Avenue. Issues Payne Avenue #08-016 This permit was issued for the reconstruction of Payne Avenue between Beaumont and Bush in St. Paul. One underground infiltration trench and one surface raingarden treat stormwater on site. The site is stable and the stormwater treatment practices has been confirmed functional. One maintenance need has been shared with City sewer maintenance staff. No surety was collected for this public project. Action Requested Approve Certificate of Completion for permit #08-016, Payne Avenue.

W:\07 Programs\Permitting\Board Memos\2019-07-10 Permit Closeout Board Memo.docx

Our Mission is to protect, manage and improve the water resources of Capitol Region Watershed District.


Capitol Region Watershed District Applicant:

Permit 19-015 Waterford Bay

Josh Wohlreich, Stoneleigh Companies 760 W. Main St. Barrington, IL 60010

Consultant: Dan Elenbaas, Kimley-Horn 767 Eustis Street, Suite 100 Saint Paul, MN 55114

Description: Construction of a 258-unit apartment building with associated surface parking lot, sidewalks, utilities and stormwater BMPs. Stormwater Management: One iron enhanced biofiltration basin and one underground filtration system. District Rule: - C, D, F Disturbed Area: 8.34 Acres Impervious Area: 4.41 Acres STAFF RECOMMENDATION: Approve with 8 Conditions:

1. Receipt of $22,100 surety. 2. Receipt of documentation of maintenance agreement recorded with Ramsey County. 3. Provide plans signed and dated by a professional engineer per the Minnesota Board of AELSLAGID. Additionally, the Minnesota license number shall be given. 4. Provide a copy of the NPDES permit. 5. Revise site-specific maintenance plan to address items a.-c. in the 6-26-19 permit report. 6. Revise plans to address items a.-d. in the 6-26-19 permit report. 7. Revise HydroCAD or Plans to correspond for items a.-b. in the 6-26-19 permit report. 8. Revise pervious curve numbers for the existing HydroCAD model. Review of recent aerial photos shows good vegetation coverage over the existing site. CRWD recommends a combination of CN 74 for areas of HSG C with good (>75%) grass cover and CN 65 for areas of HSG C with brush and grass combination.

Permit Location

Permit Report 19-015

Aerial Photo Board Meeting Date: 07-10-2019


Capitol Region Watershed District Permit Report CRWD Permit #: Review date: Project Name: Applicant: Purpose:

19‐015 June 26, 2019 Waterford Bay Dan Elenbaas Kimley‐Horn 767 Eustis Street St. Paul, MN 55114 612‐294‐7279 dan.elenbaas@kimley‐horn.com The proposed project consists of the construction of a 258‐unit apartment building with associated surface parking lot, sidewalks, and utilities. Permanent stormwater management consists of a biofiltration basin with underdrain and an underground CMP filtration system.

Location: 380 Randolph Ave, St. Paul Applicable Rules: C, D, and F Recommendation: Approve with 8 Conditions EXHIBITS: 1. Civil Plans (Sheets C000, C100, C200, C300, C301, C302, C303, C400, C401, C402, C500, C501, C502, C600, C601), by Kimley‐Horn, dated 4/26/19, recv. 6/20/19. 2. Stormwater Management Plan, by Kimley‐Horn, dated 6/19/19, recv. 6/20/19. 3. Geotechnical Evaluation, by Braun Intertec, dated 3/20/19, recv. 6/20/19. 4. Signed Draft City of Saint Paul Floodplain Application, by Kimley‐Horn, dated 4/26/19, recv. 4/29/19. 5. Floodplain Study and No‐Rise Analysis (75 Pages), by Kimley‐Horn, dated 4/19, recv. 4/29/19. 6. Operation and Maintenance Plan, by Kimley‐Horn, not dated, recv. 6/20/19. 7. SWPPP, by Kimley‐Horn, dated 6/19/19, recv. 6/20/19. 8. Declaration for Maintenance of Stormwater Facilities, by Stoneleigh Companies, dated 6/17/19, recv. 6/20/19. 9. Storm Sewer Sizing, by Kimley‐Horn, dated 6/3/19, recv. 6/20/19. HISTORY & CONSIDERATIONS: Former Island Station property demolished in 2013 under CRWD Permit #13‐029. RULE C: STORMWATER MANAGEMENT W:\07 Programs\Permitting\2019\19-015 Waterford Bay\19-015 Permit Report_R2.doc Page 1 of 6


Standards  Proposed discharge rates for the 2‐, 10‐, and 100‐year events shall not exceed existing rates.  Developments and redevelopments must reduce runoff volumes in the amount equivalent to an inch of runoff from the impervious areas of the site.  Stormwater must be pretreated before discharging to infiltration areas to maintain the long‐term viability of the infiltration area.  Developments and redevelopments must incorporate effective non‐point source pollution reduction BMPs to achieve 90% total suspended solid removal. Findings 1. A hydrograph method based on sound hydrologic theory is used to analyze runoff for the design or analysis of flows and water levels. 2. It is unknown if runoff rates for the proposed activity exceed existing runoff rates for the 2‐, 10‐, and 100‐year critical storm events. Stormwater leaving the project area is discharged into a well‐defined receiving channel or pipe and routed to a public drainage system. 3. Stormwater runoff volume retention is not achieved onsite in the amount equivalent to the runoff generated from 1.1‐inch of rainfall over the impervious surfaces of the development. a. The amount of proposed impervious is 192,270 square feet. b. Volume retention required: 192,270 ft2 x 1.1 inches x 1 ft/12 inches = 17,625 ft3 Table 1. Proposed volume retention through abstraction (i.e. infiltration, reuse). Volume Volume Retention 1.1‐inch 2‐inch Retention BMP Provided below Runoff Runoff Required outlet (cu. ft.) (cu. ft.) (cu. ft.) (cu. ft.) 17,625 None, filtration is proposed. 4. Alternative compliance has been requested due to poor soils. Fill extends down below the seasonally high groundwater level. a. The applicant did not partially comply with the volume retention standard. b. Filtration using iron‐enhanced sand media (80% credit) is proposed; filtration required: 17,625 ft3 x 1.25 credit factor = 22,031 ft3 Table 2. Proposed volume retention through iron‐enhanced filtration. Filtration Filtration 1.1‐inch 2‐inch Volume Volume BMP Runoff Runoff Required Provided below (cu. ft.) (cu. ft.) (cu. ft.) outlet (cu. ft.) Iron Enhanced Biofiltration 14,637 4,178 7,597 22,031 Total 7,597 cf

c. Filtration using sand media (55% credit) is proposed; filtration required:

W:\07 Programs\Permitting\2019\19-015 Waterford Bay\19-015 Permit Report_R2.doc Page 2 of 6


22,031 – 7,597 ft3 / 1.25 iron enhanced credit factor x 1.82 sand filter credit factor = 21,016 ft3 Table 3. Proposed volume retention through filtration (i.e. sand, enhanced). Filtration Filtration 1.1‐inch 2‐inch Volume Volume BMP Runoff Runoff Required Provided below (cu. ft.) (cu. ft.) (cu. ft.) outlet (cu. ft.) Underground CMP Filtration 22,155 12,412 22,568 21,016 Total 22,155 cf

i. Filtration volume and facility sizes have been calculated using the appropriate hydrologic soil group classification and design filtration rate. ii. The filtration areas are capable of filtering the required volume within 48 hours. iii. Stormwater runoff is pretreated to remove solids before discharging to filtration areas. d. The applicant did not partially comply with the volume retention standard at an offsite location or through the use of qualified banking credits. e. The applicant has not submitted money to be contributed to the Stormwater Impact Fund. f. The project is not linear. 5. Best management practices achieve 90% total suspended solids removal from the runoff generated on an annual basis. 6. A maintenance agreement recorded with Ramsey County has not been submitted. 7. Adequate maintenance access is provided for both the surface and underground systems. A site‐specific plan, schedule, and narrative for maintenance of the proposed stormwater management practices has been submitted. RULE D: FLOOD CONTROL Standards  Compensatory storage shall be provided for fill placed within the 100‐year floodplain.  All habitable buildings, roads, and parking structures on or adjacent to a project site shall comply with District freeboard requirements. Findings 1. There is floodplain on the property according to FEMA. 2. The total floodplain impact is 241,515 cubic feet. 3. Compensatory storage of 245,349 cubic feet is provided. 4. All habitable buildings, roads, and parking structures on or adjacent to the project site comply with CRWD freeboard requirements. RULE E: WETLAND MANAGEMENT Standard

W:\07 Programs\Permitting\2019\19-015 Waterford Bay\19-015 Permit Report_R2.doc Page 3 of 6


 Wetlands shall not be drained, filled (wholly or in part), excavated, or have sustaining hydrology impacted such that there will be a decrease in the inherent (existing) functions and values of the wetland.  A minimum buffer of 25 feet of permanent nonimpacted vegetative ground cover abutting and surrounding a wetland is required. Findings 1. There are wetlands located on or near the property boundaries to the SE and SW. 2. It is not known if CRWD staff has reviewed and approved the delineated wetland boundaries. 3. Approximately 0 square feet of wetland impact are proposed. 4. It is not known if WCA sequencing has been adequately addressed. 5. It is not known if mitigation of wetland impact is proposed. 6. A minimum buffer of 25 feet has not been provided. RULE F: EROSION AND SEDIMENT CONTROL Standards  A plan shall demonstrate that appropriate erosion and sediment control measures protect downstream water bodies from the effects of a land‐disturbing activity.  Erosion Control Plans must adhere to the MPCA Protecting Water Quality in Urban Areas Manual. Findings 1. Erosion and sediment control measures are consistent with best management practices, as demonstrated in the MPCA manual Protecting Water Quality in Urban Areas. 2. Adjacent properties are protected from sediment transport/deposition. 3. Wetlands, waterbodies and water conveyance systems are protected from erosion/sediment transport/deposition. 4. Total disturbed area is 8.34 acres; an NPDES permit is required. A SWPPP has been submitted. RULE G: ILLICIT DISCHARGE AND CONNECTION Standard  Stormwater management and utility plans shall indicate all existing and proposed connections from developed and undeveloped lands for all water that drains to the District MS4. Findings 1. New direct connections or replacement of existing connections are not proposed. 2. Prohibited discharges are not proposed. Recommendation: Approve with 8 Conditions Conditions: 1. Receipt of $22,100 surety. 2. Receipt of documentation of maintenance agreement recorded with Ramsey County. 3. Provide plans signed and dated by a professional engineer per the Minnesota Board of AELSLAGID. Additionally, the Minnesota license number shall be given. W:\07 Programs\Permitting\2019\19-015 Waterford Bay\19-015 Permit Report_R2.doc Page 4 of 6


4. Provide a copy of the NPDES permit. 5. Revise site‐specific maintenance plan to address the following: a. Remove the footer that references “UST 2nd Year Housing”. b. Include rain guardian device location on exhibit sheet and provide inspection and maintenance details for the pretreatment device. c. Include additional inspection and maintenance activities to address functionality of iron enhanced sand. 6. Revise plans to address the following: a. Revise underdrain design for the biofiltration basin and CMP filtration system to accommodate the following, as recommended by the Minnesota Stormwater Manual: i. Perforations should be 3/8 inches. Note on Underdrain Detail on Sheet C501 references 3‐inch perforations. ii. Underdrain pipes should have a minimum of three inches of washed #57 stone above and on each side of the pipe (stone is not required below the pipe). Above the stone, two inches of choking stone is needed to protect the underdrain from blockage. Current design shows three inches of Course Filter Aggregate surrounding the underdrain, which is an acceptable alternative to the washed #57 stone; however, two inches of choking stone is not provided. Choking stone is recommended to prevent sand from migrating into the course filter aggregate and the underdrain. iii. Remove porous filter fabric from around draintile. Raingarden detail on Sheet C501 references that the draintile will be wrapped with three inches of rock and a porous filter fabric. Two inches of chocking stone shall take the place of the filter fabric as specified in Condition 6.a.ii. iv. Increase filtration media depth to at least 18", as recommended by the Minnesota Stormwater Manual. Depth of filter media is calculated from the top of the filter media to the top of the choking stone around the drain tile. Raingarden Detail on Sheet C501 shows 2.5’ depth of sand measurement, but top of sand elevation (707.5’) – bottom of sand (705.25’) = 2.25’ depth of sand. Revise bottom of sand elevation to 705.0’. b. Provide a site‐specific cross‐section detail for the Underground CMP Filtration system that includes inverts of sand, draintile, rock, and CMP. c. Show location of permanently reinforced EOF for the biofiltration basin. EOF shall be at least 0.5’ below top of berm and permanent energy dissipation/stabilization of EOF shall extend to the toe of the slope to prevent erosion. Response to CRWD comments dated 4/25/19 indicate that EOF is at an elevation of 710.5’ and top of berm is at an elevation of 711.0’; however, the 711’ contour does not continue around the entire raingarden, indicating that the top of berm is less than 711.0’ d. Revise Raingarden Detail on Sheet C501 to specify the filtration media shall include 5% iron filings by weight as indicated in the Stormwater Management Plan. The submitted narrative and calculations note iron‐enhanced sand, but this was not indicated in the plans. If iron‐enhanced media is intended to be used, plants are not recommended in the bottom of the basin. 7. Revise HydroCAD or Plans to correspond for the following: W:\07 Programs\Permitting\2019\19-015 Waterford Bay\19-015 Permit Report_R2.doc Page 5 of 6


a. Pond 30P (Underground Filtration): i. Invert of 24” pipe storage is 704.0’ in HydroCAD and 704.46’ on Sheet C600 in the plans. Additionally, each upstream pipe storage with a different slope shall be modeled as a different pipe storage with the correct invert elevation (i.e. slope in HydroCAD is 0.50% and slopes for those pipes in the plans are 0.93%, 0.46% and 0.40%). ii. 6” orifices in weir wall of OCS 101 are shown with vertical orientation on Sheet C502 in the plans but are modeled with horizontal orientation in HydroCAD. b. Pond 28P (Filtration Basin South): i. Diameter of the horizontal grate is 27” in HydroCAD and 48” in the raingarden detail on Sheet C501 in the plans. 8. Revise pervious curve numbers for the existing HydroCAD model. Review of recent aerial photos shows good vegetation coverage over the existing site. CRWD recommends a combination of CN 74 for areas of HSG C with good (>75%) grass cover and CN 65 for areas of HSG C with brush and grass combination.

W:\07 Programs\Permitting\2019\19-015 Waterford Bay\19-015 Permit Report_R2.doc Page 6 of 6


H RT NO

LEGEND PROPOSED REDUCER PROPOSED TEE PROPOSED GATE VALVE PROPOSED HYDRANT PROPOSED SANITARY SEWER MANHOLE Q:\2251-01 Stoneleigh-Riverwalk St Paul\01-Disciplines & Consultants\03-Civil\TO\2205-01_ArtArchBldgDev_AI_2018-BKV_Services_Vert_Outlines-18460487.jpg

CO

PROPOSED SANITARY CLEANOUT PROPOSED WATERMAIN PROPOSED SANITARY SEWER PROPOSED DRAIN TILE PROPOSED STORM SEWER PROPOSED UNDERGROUND ELECTRIC PROPOSED TELEPHONE PROPOSED GAS MAIN

UTILITY PLAN NOTES 1.

ALL FILL MATERIAL IS TO BE IN PLACE, AND COMPACTED BEFORE INSTALLATION OF PROPOSED UTILITIES.

2.

SANITARY SEWER PIPE SHALL BE AS FOLLOWS: 8" PVC SDR35 PER ASTM D-3034, FOR PIPES LESS THAN 12' DEEP 8" PVC SDR26 PER ASTM D-3034, FOR PIPES MORE THAN 12' DEEP 6" PVC SCHEDULE 40 PER ASTM D-3034 DUCTILE IRON PIPE PER AWWA C150

3.

WATER LINES SHALL BE AS FOLLOWS: 6" AND LARGER, PVC C-900 PER ASTM D 2241 CLASS 200 UNDER COUNTY ROADS, OTHERWISE CLASS 150 4" AND LARGER DUCTILE IRON PIPE PER AWWA C150 SMALLER THAN 3" PIPING SHALL BE COPPER TUBE TYPE "K" PER ANSI 816.22 OR PVC, 200 P.S.I., PER ASTM D1784 AND D2241.

4.

MINIMUM TRENCH WIDTH SHALL BE 2 FEET.

5.

ALL WATER JOINTS ARE TO BE MECHANICAL JOINTS WITH RESTRAINTS SUCH AS THRUST BLOCKING, WITH STAINLESS STEEL OR COBALT BLUE BOLTS, OR AS INDICATED IN THE CITY SPECIFICATIONS AND PROJECT DOCUMENTS.

6.

ALL UTILITIES SHOULD BE KEPT TEN (10') APART (PARALLEL) OR WHEN CROSSING 18" VERTICAL CLEARANCE (OUTSIDE EDGE OF PIPE TO OUTSIDE EDGE OF PIPE OR STRUCTURE).

7.

CONTRACTOR SHALL MAINTAIN A MINIMUM OF 7'-5" COVER ON ALL WATERLINES.



N THE EVENT OF A VERTICAL CONFLICT BETWEEN WATER LINES, SANITARY LINES, STORM LINES AND GAS LINES, OR ANY OBSTRUCTION (EXISTING AND PROPOSED), THE SANITARY LINE SHALL BE SCH. 40 OR C900 WITH MECHANICAL JOINTS AT LEAST 10 FEET ON EITHER SIDE OF THE CENTER LINE OF THE CROSSING. THE WATER LINE SHALL HAVE MECHANICAL JOINTS WITH APPROPRIATE FASTENERS AS REQUIRED TO PROVIDE A MINIMUM OF 18" VERTICAL SEPARATION. MEETING REQUIREMENTS OF ANSI A21.10 OR ANSI 21.11 (AWWA C-151) (CLASS 50).

9.

LINES UNDERGROUND SHALL BE INSTALLED, INSPECTED AND APPROVED BEFORE BACKFILLING.

10. TOPS OF MANHOLES SHALL BE RAISED AS NECESSARY TO BE FLUSH WITH PROPOSED PAVEMENT ELEVATIONS, AND TO BE ONE FOOT ABOVE FINISHED GROUND ELEVATIONS, IN GREEN AREAS, WITH WATERTIGHT LIDS.

222 North Second Street Long & Kees Bldg, Suite 101 Minneapolis, MN 55401 Telephone: 612.339.3752 www.bkvgroup.com EOE CONSULTANTS

SITE PLAN SUBMITTAL 04/26/19 PROJECT TITLE

STONELEIGH WATERFORD BAY

11. ALL CONCRETE FOR ENCASEMENTS SHALL HAVE A MINIMUM 28 DAY COMPRESSION STRENGTH AT 3000 P.S.I. 12. EXISTING UTILITIES SHALL BE VERIFIED IN FIELD PRIOR TO INSTALLATION OF ANY NEW LINES. 13. REFER TO INTERIOR PLUMBING DRAWINGS FOR TIE-IN OF ALL UTILITIES. 14. CONTRACTOR IS RESPONSIBLE FOR COMPLYING TO THE SPECIFICATIONS OF THE CITY OF ST. PAUL AND/OR STATE OF MN WITH REGARDS TO MATERIALS AND INSTALLATION OF THE WATER AND SEWER LINES. 15. THE CONTRACTOR IS SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF EXISTING UTILITIES AS SHOWN ON THESE PLANS IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES, AND WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED ON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE APPROPRIATE UTILITY COMPANIES AT LEAST 72 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATION OF UTILITIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES WHICH CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THE PLANS. 16. CONTRACTOR IS RESPONSIBLE FOR ALL NECESSARY INSPECTIONS AND/OR CERTIFICATIONS REQUIRED BY CODES AND/OR UTILITY SERVICE COMPANIES. 17. CONTRACTOR SHALL COORDINATE WITH ALL UTILITY COMPANIES FOR INSTALLATION REQUIREMENTS AND SPECIFICATIONS. 18. CONTRACTOR SHALL REFERENCE ARCH / MEP PLANS FOR SITE LIGHTING AND ELECTRICAL PLAN. 19. BACKFLOW DEVICES (DDCV AND PRZ ASSEMBLIES) AND METERS ARE LOCATED IN THE INTERIOR OF THE BUILDING. REF. ARCH / MEP PLANS. 20. ALL ONSITE WATERMAINS AND SANITARY SEWERS SHALL BE PRIVATELY OWNED AND MAINTAINED. 21. ALL WATERMAIN STUBOUTS SHALL BE MECHANICALLY RESTRAINED WITH REACTION BLOCKING.

CITY OF SAINT PAUL NOTES 1.

WATER SERVICES TO BE INSTALLED ACCORDING TO SPRWS “STANDARDS FOR THE INSTALLATION OF WATER MAINS.

2.

A FOUR-SIDED TRENCH BOX IS REQUIRED ON ALL EXCAVATIONS DEEPER THAN 5 FEET WHERE UNDERGROUND WORK OR INSPECTION IS TO BE PERFORMED BY SPRWS. FOR ALL WET TAPS TO BE PERFORMED BY SPRWS, A MINIMUM TRENCH BOX SIZE OF 8 FEET HIGH X 8 FEET WIDE X 10 FEET LONG IS REQUIRED. LADDERS ARE REQUIRED AND MUST EXTEND 3 FEET ABOVE THE SURFACE OF THE TRENCH. SIDEWALKS, PAVEMENTS, DUCTS AND APPURTENANT STRUCTURES SHALL NOT BE UNDERMINED UNLESS A SUPPORT SYSTEM OR ANOTHER METHOD OF PROTECTION IS PROVIDED. TRENCHES IN EXCESS OF 20 FEET IN DEPTH MUST BE SIGNED OFF BY A REGISTERED PROFESSIONAL ENGINEER. EXCAVATED MATERIAL MUST BE KEPT A MINIMUM OF 2 FEET FROM THE EDGE OF THE TRENCH.

3.

MAINTAIN 8 FEET OF COVER OVER ALL WATER MAINS AND SERVICES.

4.

PIPE MATERIAL FOR 8” DUCTILE IRON PIPE MUST BE CLASS 52, PIPE MATERIAL FOR 6” AND 4” DUCTILE IRON PIPE MUST BE CLASS 53. THE EXTERIOR OF DUCTILE IRON PIPE SHALL BE COATED WITH A LAYER OF ARC-SPRAYEDZINC PER ISO 8179. THE INTERIOR CEMENT MORTAR LINING SHALL BE APPLIED WITHOUT ASPHALT SEAL COAT.

5.

PIPE MUST BE WRAPPED IN V-BIO POLYWRAP ENCASEMENT.

6.

MAINTAIN 3 FEET VERTICAL SEPARATION BETWEEN WATER AND SEWER PIPES OR A 12 INCH SEPARATION WITH 4 INCH HIGH DENSITY INSULATION PER SPRWS STANDARD PLATE D-10 FOR TYPICAL WATER MAIN OFFSETS.

7.

REFER TO SPRWS “STANDARDS FOR THE INSTALLATION OF WATER MAINS” STANDARD PLATE D-11 FOR RESTRAINED PIPE REQUIREMENT.

8.

ALL WATER SERVICE VALVE BOXES WITHIN CONSTRUCTION AREA MUST BE EXPOSED AND BROUGHT TO GRADE UPON COMPLETION OF CONSTRUCTION.

9.

ALL PIPE WORK INSIDE OF PROPERTY TO BE PERFORMED BY A PLUMBER LICENSED BY THE STATE OF MINNESOTA AND CERTIFIED BY THE CITY OF SAINT PAUL. SPRWS REQUIRES SEPARATE OUTSIDE AND INSIDE PLUMBING PERMITS FOR EACH NEW WATER SERVICE.

10. WATER FACILITY PIPEWORK WITHIN RIGHT OF WAY TO BE INSTALLED BY SPRWS. EXCAVATION AND RESTORATION BY OWNER'S CONTRACTOR. 11. THE CONTRACTOR PROVIDING EXCAVATION IS RESPONSIBLE FOR OBTAINING ALL EXCAVATION AND OBSTRUCTION PERMITS REQUIRED BY ANY GOVERNING AUTHORITY. 12. ALL PRIMARY ROOF DRAINS SHALL BE CONNECTED TO THE STORM SEWER OR TO SOME OTHER PLACE OF DISPOSAL SATISFACTORY TO THE AUTHORITY HAVING JURISDICTION. MPC 4714.1101.1. 13. SECONDARY ROOF DRAINAGE SHALL DRAIN TO AN APPROVED PLACE OF DISPOSAL IN THE FORM OF SCUPPERS (IF THE ROOF IS LESS THAN 25 FEET) OR SECONDARY ROOF DRAINS (IF THE ROOF IS OVER 25 FEET) AND INSTALLED PER MPC 4714.1101 & 1102, AND MINNESOTA STATE BUILDING CODE 1503.4 1-5. SECONDARY ROOF DRAINAGE MUST DISCHARGE ONTO PERMEABLE SOILS AND CANNOT DRAIN ONTO THE SIDEWALK. MPC 4714.1101.1 BOTH PRIMARY AND SECONDARY ROOF DRAINAGE SYSTEMS MUST MEET THIS REQUIREMENT. MINNESOTA HAS SPECIFIC REQUIREMENTS TO ADDRESS SEASONAL CONDITIONS OF FREEZE AND THAW WHEN THE DISCHARGE FROM ROOF DRAINS COULD CREATE UNSAFE, ICY CONDITIONS ON SIDEWALKS. IT IS SUGGESTED THAT A PROPER POINT OF DISCHARGE THAT CAN BE APPROVED BY THE AUTHORITY HAVING JURISDICTION FOR SECONDARY ROOF DRAINAGE IS IN THE FORM OF SECONDARY ROOF DRAINS PIPED INTERNALLY, DOWN TO WITHIN 18 INCHES OF GRADE, THROUGH THE OUTSIDE WALL, ONTO A SPLASH BLOCK INSTALLED PER MPC 1101.5.3, AND LAID OVER PERMEABLE SOILS OF AN ADEQUATE AMOUNT WHERE SATURATION OF THE SOIL WILL NOT OCCUR.

2018 KIMLEY-HORN AND ASSOCIATES, INC. 767 EUSTIS STREET, SUITE 100, ST. PAUL, MN 55114 PHONE: 651-645-4197 WWW.KIMLEY-HORN.COM

CERTIFICATION

DRAWN BY CHECKED BY COMMISSION NUMBER

2251.03

SHEET TITLE

UTILITY PLAN SHEET NUMBER

C600 © 2018 BKV Group


Capitol Region Watershed District Applicant:

Permit 19-017 Urban Academy Addition

Ryan Rehkamp Lumen Christi Catholic Community 2055 Bohland Ave St. Paul, MN 55116

Consultant: Eric Meyer Larson Engineering, Inc. 3524 Labore Road White Bear Lake, MN 55110

Description: New gym addition on the southwest side of the existing building, new paved parking, and associated grading/utilities. Stormwater Management: One surface filtration basin. District Rule: - C, D, F Disturbed Area: 2.0 Acres Impervious Area: 1.263 Acres

STAFF RECOMMENDATION: Approve with 8 Conditions:

1. 2. 3. 4. 5.

Receipt of $6,300 surety. Receipt of documentation of maintenance agreement recorded with Ramsey County. Provide a copy of the NPDES permit. Provide a SWPPP that satisfies NPDES permit requirements. Increase filtration media depth to at least 18", as recommended by the Minnesota Stormwater Manual. The full 18” depth of filter media does not need to be provided directly above the draintile but shall be throughout the rest of the basin. 6. Revise the volume below the low outlet labeled on Sheet C300 to reflect the volume between the low outlet and the surface of the rain garden. CRWD does not grant filtration volume credit for voids within the filter media. 7. Include a site-specific maintenance plan that includes items a.-h. in the 6-24-19 permit report. 8. Revise rain garden design so that the EOF is not used for the 100-yr event. Update 100-yr HWL labeled on the plans. The 100-yr HWL shall be below the EOF and the EOF shall be at least 0.5’ below top of berm.

Montreal

Davern

Permit Location

Permit Report 19-017

Aerial Photo Board Meeting Date: 07-10-2019


Capitol Region Watershed District Permit Report CRWD Permit #: Review date: Project Name: Applicant: Purpose:

19‐017 June 24, 2019 Urban Academy Addition Ryan Rehkamp Lumen Christi Catholic Community 2055 Bohland Ave St. Paul, MN 55116 651‐698‐5581 rrehkamp@lumenchristic.org Construction of a new gym addition on the southwest side of the existing building and new paved parking. Stormwater management consists of one filtration basin.

Location: 1688 Montreal Avenue, St. Paul 55116 Applicable Rules: C, D, and F Recommendation: Approve with 8 Conditions EXHIBITS: 1. Civil Plans (C100, C200, C201, C300, C400, C500, C501), by Larson Engineering, dated 6/17/19, rcvd. 6/19/19. 2. Stormwater Calculations, by Larson Engineering, dated 6/17/19, rcvd. 6/19/19. 3. Declaration for Maintenance of Stormwater Facilities, by Lumen Christi Catholic Community, dated 6/14/19, rcvd. 6/19/19. HISTORY & CONSIDERATIONS: None. RULE C: STORMWATER MANAGEMENT Standards  Proposed discharge rates for the 2‐, 10‐, and 100‐year events shall not exceed existing rates.  Developments and redevelopments must reduce runoff volumes in the amount equivalent to an inch of runoff from the impervious areas of the site.  Stormwater must be pretreated before discharging to infiltration areas to maintain the long‐term viability of the infiltration area. W:\07 Programs\Permitting\2019\19-017 Urban Academy Addition\19-017 Permit Report_R2b.doc Page 1 of 4


 Developments and redevelopments must incorporate effective non‐point source pollution reduction BMPs to achieve 90% total suspended solid removal. Findings 1. A hydrograph method based on sound hydrologic theory is used to analyze runoff for the design or analysis of flows and water levels. 2. Runoff rates for the proposed activity do not exceed existing runoff rates for the 2‐, 10‐, and 100‐year critical storm events. Stormwater leaving the project area is discharged into a well‐defined receiving channel or pipe and routed to a public drainage system. 3. Stormwater runoff volume retention is not achieved onsite in the amount equivalent to the runoff generated from 1.1‐inch of rainfall over the impervious surfaces of the development. a. The amount of proposed impervious is 55,021 square feet. b. Volume retention required: 55,021 ft2 x 1.1 inches x 1 ft/12 inches = 5,044 ft3 Table 1. Proposed volume retention through abstraction (i.e. infiltration, reuse). Volume Volume Retention 1.1‐inch 2‐inch Retention BMP Provided below Runoff Runoff Required outlet (cu. ft.) (cu. ft.) (cu. ft.) (cu. ft.) None, filtration is proposed. 5,044 Total 0 cf 4. Alternative compliance has been requested due to poorly infiltrating soils. a. The applicant did comply with the volume retention standard. b. Filtration using sand media (55% credit) is proposed; filtration required: 5,044 ft3 x 1.82 credit factor = 9,180 ft3 Table 2. Proposed volume retention through filtration (i.e. sand, enhanced). Filtration Filtration Volume 1.1‐inch 2‐inch Volume BMP Provided below Runoff Runoff Required outlet (cu. ft.) (cu. ft.) (cu. ft.) (cu. ft.) Rain Garden 14,538 5,403 9,825 9,180 Total 9,825 cf i. Filtration volume and facility size has been calculated using the appropriate hydrologic soil group classification and design filtration rate. ii. The filtration area is capable of filtering the required volume within 48 hours. iii. Stormwater runoff is pretreated to remove solids before discharging to filtration areas. c. Banking of excess volume retention is not proposed.

W:\07 Programs\Permitting\2019\19-017 Urban Academy Addition\19-017 Permit Report_R2b.doc Page 2 of 4


d. The applicant has not submitted money to be contributed to the Stormwater Impact Fund. e. The project is not linear. 5. Best management practices achieve 90% total suspended solids removal from the runoff generated on an annual basis. 6. A maintenance agreement recorded with Ramsey County has not been submitted. 7. Adequate maintenance access is provided for surface systems. A site‐specific plan, schedule, and narrative for maintenance of the proposed stormwater management practices has not been submitted. RULE D: FLOOD CONTROL Standards  Compensatory storage shall be provided for fill placed within the 100‐year floodplain.  All habitable buildings, roads, and parking structures on or adjacent to a project site shall comply with District freeboard requirements. Findings 1. There is no floodplain on the property according to FEMA. 2. Compensatory storage is not needed. 3. All habitable buildings, roads, and parking structures on or adjacent to the project site comply with CRWD freeboard requirements. RULE E: WETLAND MANAGEMENT Standard  Wetlands shall not be drained, filled (wholly or in part), excavated, or have sustaining hydrology impacted such that there will be a decrease in the inherent (existing) functions and values of the wetland.  A minimum buffer of 25 feet of permanent nonimpacted vegetative ground cover abutting and surrounding a wetland is required. Findings 1. There are no known wetlands located on the property. RULE F: EROSION AND SEDIMENT CONTROL Standards  A plan shall demonstrate that appropriate erosion and sediment control measures protect downstream water bodies from the effects of a land‐disturbing activity.  Erosion Control Plans must adhere to the MPCA Protecting Water Quality in Urban Areas Manual. Findings 1. Erosion and sediment control measures are consistent with best management practices, as demonstrated in the MPCA manual Protecting Water Quality in Urban Areas. 2. Adjacent properties are protected from sediment transport/deposition. 3. Wetlands, waterbodies and water conveyance systems are protected from erosion/sediment transport/deposition. W:\07 Programs\Permitting\2019\19-017 Urban Academy Addition\19-017 Permit Report_R2b.doc Page 3 of 4


4. Total disturbed area is 2.0 acres; an NPDES permit is required. A SWPPP has not been submitted. RULE G: ILLICIT DISCHARGE AND CONNECTION Standard  Stormwater management and utility plans shall indicate all existing and proposed connections from developed and undeveloped lands for all water that drains to the District MS4. Findings 1. New direct connections or replacement of existing connections are not proposed. 2. Prohibited discharges are not proposed. Recommendation: Approve with 8 Conditions Conditions: 1. Receipt of $6,300 surety. 2. Receipt of documentation of maintenance agreement recorded with Ramsey County. 3. Provide a copy of the NPDES permit. 4. Provide a SWPPP that satisfies NPDES permit requirements. 5. Increase filtration media depth to at least 18", as recommended by the Minnesota Stormwater Manual. The full 18” depth of filter media does not need to be provided directly above the draintile but shall be throughout the rest of the basin. 6. Revise the volume below the low outlet labeled on Sheet C300 to reflect the volume between the low outlet and the surface of the rain garden. CRWD does not grant filtration volume credit for voids within the filter media. 7. Include a site‐specific maintenance plan that includes the following: a. List of all stormwater management practices. b. Person(s) responsible for maintenance of stormwater devices. c. Frequency of inspection/ indicator that maintenance is needed. d. Description of inspection activities. e. Description of maintenance activities. f. Inspect in winter months to ensure plowed snow is not being stored on filtration practices. g. Establish a watering plan that extends a minimum of one year after planting. h. Annual maintenance to include trimming vegetation, replacing vegetation where needed, mulch replacement, and removal of accumulated sediment and debris. 8. Revise rain garden design so that the EOF is not used for the 100‐yr event. Update 100‐ yr HWL labeled on the plans. The 100‐yr HWL shall be below the EOF and the EOF shall be at least 0.5’ below top of berm.

W:\07 Programs\Permitting\2019\19-017 Urban Academy Addition\19-017 Permit Report_R2b.doc Page 4 of 4


15" RCP

RIM = 250.0 INV N = 238.4 INV S = 237.9

T

T

D

RIM = INV = 239.18

4 C500

RIM = 252.0* INV = 240.0

30' PARKING SETBACK

256

4 C501

RIP-RAP AT OUTLET

5 C501

RAINGARDEN BTM = 262.00 100-YR HWL = 264.46 17,688 C.F. BELOW OUTLET

254

D

5 C500

260

WV

252

258

WV

262

RIM = INV = 240.42

256

265 264

4 C500

263 RELOCATED PLAYGROUND

264.50 EO

4 C501

5 C500

RIP-RAP AT OUTLET

15" VIT. PIPE

264

258

6 26

4 C501

RIP-RAP AT OUTLET

10267.00 TC C501 266.67 GL

268.26 TC 267.75 GL

3.0 %

266.40 TC 265.90 GL

266.50 TC 266.00 GL

%

4 C501

3.0

265.92 TC 265.42 RIM/GL

266.59 RIM

4 C500

RIP-RAP AT OUTLET

4 C500

260

26 7

254 262

266 26 8

10' SIDE SETBACK

RIM = 252.1 INV E = 241.7 INV W = 238.4

268

269.03 FFE

269.03 FE

269.13 TC 268.63 GL

POSSIBLE STOCKPILE LOCATION

268.66 TC 268.16 GL

267.50 TC 267.00 GL

269.33 TC 268.83 GL

269.74 TC 268.24 GL

268.25 TC 267.75 GL

269.12 B

269.12 B

269.12 B

269.12 B

269.12 B

269.12 B

269.12 B

268.80 TC 268.30 GL

266

270.20 TC 269.70 GL

269.90 TC 269.40 GL

269.03 FFE

269.40 B

269.40 B

269.40 B

269.40 B

269.40 B

269.40 B

269.33 TC 269.00 GL

270.70 FFE

270.32 C

269.82 GL

269.82 GL

270.20 TC 269.70 GL

270.20 TC 269.70 GL

7 C500

270

SEE ARCH FFE = 270.70 (ARCH 100')

FP

270.32 C

270.20 TC 269.70 GL

270.90* G

270.90* G

270.76* FFE

270.67* C

271.23 TC 270.90 GL*

271.02* G

270.96* G

270.70* FFE

270.34* FFE

270.39* C

270.26* C

ROCK CONSTRUCTION ENTRANCE

268

269.50 TC 269.00 GL

9 26

268.60 TC 268.10 GL

1.5 %

266

PROPOSED ADDITION FFE = 269.03 (ARCH 98'-4")

264

268

D.I.P.

48" RCP

48" RCP

262

265

270

AVENUE 272

EXISTING TRASH AND RECYCLING

2 27

DAVERN STREET

E

G AC

274

SHED

4 27

21" RCP

265 266

270

0 26 26 9

4 26

EXISTING 2-STORY BRICK BUILDING 1668 MONTREAL AVENUE

8 26 270

0 27

WOOD RAMP WOOD RAMP

MONTREAL

27 4

276

6 27

2 27

7 26

0 25

265

264

263

252

E

EX F

Boulevards shall be restored with a minimum of 4" of topsoil. All construction shall be performed in accordance with state and local standard specifications for construction. Notify Capital Region Watershed District at least 24 hours before construction of stormwater BMP's.

7. 8. 9.

All grading operations shall be conducted in a manner to minimize the potential for site erosion. Sediment control practices must be established on all down gradient perimeters before any up gradient land disturbing activities begin. All exposed soil areas must be stabilized as soon as possible to limit soil erosion but in no case later than 14 days after the construction activity in that portion of the site has temporarily or permanently ceased. Temporary stockpiles without significant silt, clay or organic components (e.g., clean aggregate stockpiles, demolition concrete stockpiles, sand stockpiles) and the constructed base components of roads, parking lots and similar surfaces are exempt from this requirement. The normal wetted perimeter of any temporary or permanent drainage ditch or swale that drains water from any portion of the construction site, or diverts water around the site, must be stabilized within 200 lineal feet from the property edge, or from the point of discharge into any surface water. Stabilization of the last 200 lineal feet must be completed within 24 hours after connecting to a surface water. Stabilization of the remaining portions of any temporary or permanent ditches or swales must be complete within 14 days after connecting to a surface water and construction in that portion of the ditch has temporarily or permanently ceased. Pipe outlets must be provided with energy dissipation within 24 hours of connection to surface water.

6.

7.

8.

9.

28. Engineered soil shall remain uncontaminated (not mixed with other soil) before and during installation.

0

27. The bottom excavation surface of infiltration areas shall be level without dips or swales.

10

20

NORTH

26. Contractor shall submit Notice of Termination for MPCA-NPDES permit within 30 days after Final Stabilization.

25. All permanent sedimentation basins must be restored to their design condition immediately following stabilization of the site.

24. Upon completion of the project and stabilization of all graded areas, all temporary erosion control facilities (silt fences, hay bales, etc.) shall be removed from the site.

23. All liquid and solid wastes generated by concrete washout operations must be contained in a leak-proof containment facility or impermeable liner. A compacted clay liner that does not allow washout liquids to enter ground water is considered an impermeable liner. The liquid and solid wastes must not contact the ground, and there must not be runoff from the concrete washout operations or areas. Liquid and solid wastes must be disposed of properly and in compliance with MPCA regulations. A sign must be installed adjacent to each washout facility to inform concrete equipment operators to utilize the proper facilities.

22. External washing of trucks and other construction vehicles must be limited to a defined area of the site. Runoff must be contained and waste properly disposed of. No engine degreasing is allowed onsite.

21. Oil, gasoline, paint and any hazardous substances must be properly stored, including secondary containment, to prevent spills, leaks or other discharge. Restricted access to storage areas must be provided to prevent vandalism. Storage and disposal of hazardous waste must be in compliance with MPCA regulations.

20. Collected sediment, asphalt and concrete millings, floating debris, paper, plastic, fabric, construction and demolition debris and other wastes must be disposed of properly and must comply with MPCA disposal requirements.

19. Temporary soil stockpiles must have silt fence or other effective sediment controls, and cannot be placed in surface waters, including stormwater conveyances such as curb and gutter systems, or conduits and ditches unless there is a bypass in place for the stormwater.

18. All infiltration areas must be inspected to ensure that no sediment from ongoing construction activity is reaching the infiltration area and these areas are protected from compaction due to construction equipment driving across the infiltration area.

17. All soils tracked onto pavement shall be removed daily.

16. If sediment escapes the construction site, off-site accumulations of sediment must be removed in a manner and at a frequency sufficient to minimize off-site impacts.

15. All silt fences must be repaired, replaced, or supplemented when they become nonfunctional or the sediment reaches 1/3 of the height of the fence. These repairs must be made within 24 hours of discovery, or as soon as field conditions allow access. All repairs shall be recorded in the SWPPP.

14. Inspect the construction site once every seven days during active construction and within 24 hours after a rainfall event greater than 0.25 inches in 24 hours. All inspections shall be recorded in the SWPPP.

13. In areas where concentrated flows occur (such as swales and areas in front of storm catch basins and intakes) the erosion control facilities shall be backed by stabilization structure to protect those facilities from the concentrated flows.

12. All storm sewer catch basins not needed for site drainage during construction shall be covered to prevent runoff from entering the storm sewer system. Catch basins necessary for site drainage during construction shall be provided with inlet protection.

11. All storm sewers discharging into wetlands or water bodies shall outlet at or below the normal water level of the respective wetland or water body at an elevation where the downstream slope is 1 percent or flatter. The normal water level shall be the invert elevation of the outlet of the wetland or water body.

10. All riprap shall be installed with a filter material or soil separation fabric and comply with the Minnesota Department of Transportation Standard Specifications.

All construction site entrances shall be surfaced with crushed rock across the entire width of the entrance and from the entrance to a point 50' into the construction zone. The toe of the silt fence shall be trenched in a minimum of 6�. The trench backfill shall be compacted with a vibratory plate compactor.

3.

5.

Erosion control measures shown on the erosion control plan are the absolute minimum. The contractor shall install temporary earth dikes, sediment traps or basins, additional siltation fencing, and/or disk the soil parallel to the contours as deemed necessary to further control erosion. All changes shall be recorded in the SWPPP.

2.

4.

Owner and Contractor shall obtain MPCA-NPDES permit. Contractor shall be responsible for all fees pertaining to this permit. The SWPPP shall be kept onsite at all times. Install temporary erosion control measures (inlet protection, silt fence, and rock construction entrances) prior to beginning any excavation or demolition work at the site.

1.

EROSION CONTROL NOTES

Where driveways, sidewalks or other surface paving are removed all concrete, asphalt and base materials shall be removed. Boulevard soils are to be protected during construction. Soil compaction due to construction activities shall be mitigated and soils loosened prior to final grading.

6.

Restore all disturbed areas with 4� of good quality topsoil and seed.

4. 5.

All elevations with an asterisk (*) shall be field verified. If elevations vary significantly, notify the Engineer for further instructions. Grades shown in paved areas represent finish elevation.

2. 3.

Tree protection consisting of snow fence or safety fence installed at the drip line shall be in place prior to beginning any grading or demolition work at the site.

GRADING NOTES

SPOT ABBREVIATIONS: TC - TOP OF CURB GL - GUTTER LINE B - BITUMUNOUS C - CONCRETE G - GRADE FFE - FINISHED FLOOR ELEV. EO - EMERGENCY OVERFLOW (*) - EXISTING TO BE VERIFIED

CONCRETE WASHOUT STATION

INLET PROTECTION

EROSION CONTROL BLANKET

RIP-RAP / ROCK CONST. ENTRANCE

SILT FENCE SEDIMENT LOG

EXISTING CONTOURS PROPOSED CONTOURS - MAJOR INTERVAL PROPOSED CONTOURS - MINOR INTERVAL GRADE BREAK LINE GRADE SLOPE

1.

950.00 TC 949.50 GL

2.0%

950 950 949

LEGEND

40

POPE ARCHITECTS

5/31/19 6/17/19

SITE PLAN REVIEW SUBMITTAL PERMIT SET

44592

EGM

KBK

12196044

Lic. No.:

C300

SHEET

Date: 5/31/2019

Eric Meyer, P.E.

I hereby certify that this plan, specifications or report was prepared by me or under my direct supervision and that I am a duly Licensed Professional Engineer under the laws of the state of Minnesota.

3/29/19

SITE PLAN REVIEW SUBMITTAL

GRADING AND EROSION CONTROL PLAN

C 2019 Larson Engineering, Inc. All rights reserved.

3524 Labore Road White Bear Lake, MN 55110 651.481.9120 (f) 651.481.9201 www.larsonengr.com

Engineering, Inc.

Larson

URBAN ACADEMY ADDITION & RENOVATION 1688 MONTREAL AVE SAINT PAUL, MN 55116

1295 BANDANA BLVD N, SUITE 200 ST. PAUL, MN 55108-2735 (651) 642-9200 www.popearch.com


June 19, 2019 Board Meeting V. Action Item A) Approve Minutes of June 5, 2019 Regular Board Meeting (Sylvander)

Regular Meeting of the Capitol Region Watershed District (CRWD) Board of Managers, for Wednesday, June 19, 2019, 5:00 p.m. at the office of CRWD, 595 Aldine Street, St. Paul, Minnesota.

REGULAR MEETING MINUTES I.

A)

Call to Order of Regular Meeting (Vice President Mary Texer)

Managers Joe Collins, absent w/notice Seitu Jones Shirley Reider Rick Sanders Mary Texer

B)

Staff Present Public Attendees Mark Doneux, CRWD Jessica Bromelkamp, CRWD Forrest Kelley, CRWD Lindsay Schwantes, CRWD Michelle Sylvander, CRWD Bob Fossum, CRWD James Mogen, Ramsey County Attorney

Review, Amendments and Approval of the Agenda.

Motion 19-108: Approve the Agenda of June 19, 2019. Reider/Jones Unanimously Approved II.

Public Comment – For Items not on the Agenda

Manager Reider, shared that she read an article in the Roseville Review regarding Twin Lake located in Little Canada and managed by the Ramsey-Washington Watershed District. Manager Reider was glad to see that the Watershed was being noticed but at the same time receiving negative publicity for the raising lake level and flooding of homes. Manager Reider shared concerns about looking to the future and CRWD being prepared for a negative press release. CRWD has been very proactive with communications. III.

Permit Applications and Program Updates A) Permit #09-011 Magnolia Earl – Closure (Hosch)


Ms. Hosch stated that this permit was issued for the reconstruction of residential streets and associated utilities in the neighborhood of Magnolia and Earl on the east side of St. Paul. The project split the boundary with the Ramsey Washington Metro Watershed District. CRWD stormwater requirements were met with one infiltration swale and deferral of volume reduction credits. An additional 344 cf of treatment was constructed which would reduce the overall credit debit to 18,012 cf (originally 18,356 cf). The site is stable, and the stormwater treatment practice has been confirmed functional. No surety was collected for this project. Manager Texer asked if there were any enforcements in place for maintenance. Manager Jones asked for clarification that this was a 2009 project. Ms. Hosch replied that yes, the project permit was issued in 2009 and the site is being maintained. Motion 19-109: Approve volume bank withdrawal of 18,012 cubic feet and Certificate of Completion for permit #09-011, Magnolia-Earl. Reider/Jones Unanimously Approved B) Permit #15-013 Jamestown Homes – Closure (Hosch) Ms. Hosch reviewed permit #15-013 Jamestown Homes. This permit was issued for the renovation of an existing apartment complex at Central and Kent in St. Paul. Stormwater requirements were met with one underground filtration system. The site is stable, and the stormwater treatment practice has been confirmed functional. $6,800 surety is available to return. Motion 19-110: Approve $6,800 surety return and Certificate of Completion for permit #15-013, Jamestown Homes. Reider/Jones Unanimously approved C) Permit #15-039 Sunrise Banks Office Building - Closure (Hosch) Ms. Hosch reviewed permit #15-039 Sunrise Banks Office Building. This permit was issued for the redevelopment at Wabash and Curfew in St. Paul. Stormwater requirements were met with five surface iron-enhanced filtration basins. The site is stable, and the stormwater treatment practices have been confirmed functional. $15,900 surety is available to return. Motion 19-111: Approve $15,900 surety return and Certificate of Completion for permit #15-039, Sunrise Banks Office Building. Reider/Jones Unanimously approved


IV.

Special Reports No Special Report

V.

Action Items A) AR: (Sylvander).

Approve Minutes of the June 5, 2019 Board Workshop & Regular Meeting

Motion 19-112: Approve the Minutes of the June 5, 2019 Board Workshop and Regular Meeting. Reider/Jones Unanimously approved B)

AR:

Approve May Accounts Payable/Receivable (Sylvander)

Motion 19-113: Approve May 2019 Accounts Payable/Receivable and Budget Report and direct Board Treasurer and President to endorse and disperse checks for these payments. Reider/Jones Unanimously approved C) AR: Approve Consultant Services Agreement for Communications & Engagement Plan with Tunheim Partners, Inc. (Bromelkamp) Ms. Bromelkamp reviewed that CRWD’s communications and engagement efforts have expanded significantly since the Education and Outreach Plan was developed in 2009. Steps have been taken to prioritize work through subsequent studies and plans, a unifying document is needed to improve coordination across divisions, identify and prioritize key audiences and programs, and to establish tools for measuring success. A Request for Qualifications to develop a Communications & Engagement Plan was distributed. A review committee was formed, and three firms were interviewed. The committee selected Tunheim for the project. The Review Committee included CAC member Ms. Pat Cavanaugh, Manager Shirely Reider, Manager Rick Sanders and staff member Jessica Bromelkamp. Motion 19-114: Authorize the administrator to execute a consultant services agreement not to exceed $70,000 with Tunheim to develop a Communications & Engagement Plan for CRWD. Reider/Jones Unanimously approved D)

AR:

Authorize Full-Time Temporary Outreach Assistant Position (Bromelkamp)

Ms. Bromelkamp shared that funding has been budgeted for a new Communications Associate position. Mary Van Sant was hired and began working in this role on April 29, 2019. The Communications & Engagement Division also consists of the Community Outreach Coordinator, Lindsay Schwantes and GreenCorps member Megan Frisvold. Ms. Frisvold’s term with CRWD ends in late August and Ms.


Schwantes will be on maternity leave from July through late September. Ms. Bromelkamp proposed to use the remaining Communications Associate budget to hire Ms. Frisvold as a Grade 6, Full-Time Temporary Outreach Assistant through December 31, 2019. Manager Jones inquired about Ms. Frisvold’s current responsibilities; Ms. Bromelkamp shared that Ms. Frisvold’s assignments are expected to be complete in August. Motion 19-115: Authorize staff to hire Megan Frisvold as a Grade 6, Full Time Temporary staff member from September through December 2019. Reider/Jones Unanimously approved E)

AR:

Approve Promotion of Sarah Wein to Technical Specialist II (Fossum)

Mr. Fossum reviewed that the Monitoring, Research and Maintenance Division over the last several years has evolved with several roles and responsibilities. With these changes there is a need and opportunity to re-establish the Monitoring Coordinator Position in this Division. The Personnel Committee is recommending Sarah Wein be promoted to the Technical Specialist II (Monitoring Coordinator) position. The Monitoring Coordinator will lead the planning, implementation, quality control and reporting of the District’s monitoring program. Motion 19-116:

Approve Promotion of Sarah Wein to Technical Specialist II position.

Reider/Jones Unanimously approved F)

AR:

Approve City of St. Paul Local Surface Water Management Plan (Kelley)

Mr. Kelley provided a review of the requirement of citiesto complete a surface water management plan (SWMP) to identify how water resources will be protected and improved. Local Surface Water Management plans must identify local controls consistent with the plans and regulations of watershed districts. The City has been working through a process to update the stormwater requirements. St. Paul’s new proposed ordinance adopts a Stormwater Management Design Standards document that directly references CRWD and RWMWD’s Rule C Stormwater Rules. Mr. Kelley provided an update on CRWD’s review & comment, and highlighted the proposed ordinance changes and the associated Stormwater Management Design Standards Document. One item not included in the updated ordinance is water quality and volume reduction requirements for small sites, but the intent would be to address this within the 2020 WMP process. Manager Sanders asked about other cities’ standards. Mr. Kelley replied that other cities have small sites standards consistent with CRWD rules. Motion 19-117:

Approve City of St. Paul’s Local Surface Water Management Plan.

Reider/Jones Unanimously approved


G)

AR:

Approve 2019-2020 Professional Service Providers (Zwonitzer)

Administrator Doneux reviewed in place of Mr. Zwonitzer and shared that CRWD adopted a policy for soliciting professional services in 2010 and solicits statements of qualifications from interested consultants on a bi-annual basis. The last time CRWD staff solicited qualifications from consultants was in early 2017 for the 2017-2018 consultant pool. Staff have reviewed Statements of Qualifications (SOQs) from 28 firms and determined their qualifications for specific service areas. Twenty-eight Statements of Qualifications (SOQs) have been reviewed. Fifteen of the submittals were from the 20172018 pool, thirteen are new firms from 2019-2020. Of the new firms, six are disadvantage business enterprises (DBE) bringing the total DBE firms in the pool to seven. 20:30 Kevin from City of St. Paul– diversity plan Motion 19-118:

Approve 2019-2020 Professional Services Consulting Pool.

Reider/Sanders Unanimously approved H)

AR:

Approve CRWD 2018 MS4 Annual Report

Administrator Doneux reviewed in place of Ms. Eleria and provided the Board of Managers with an update on the MS4 Annual Report. CRWD is required to prepare and submit an annual report of activities and accomplishments associated with its stormwater pollution prevention program (SWPPP) by June 30th to MN Pollution control Agency (MPCA). CRWD staff propose that the public comment period on CRWD’s 2018 SWPPP work commence on June 6th and end on June 27th. Announcements of the public comment period and public meeting have been published in the Saint Paul Pioneer Press and CRWD’s website. The 2018 annual report will be available on CRWD’s website. No public in attendance, no comments were made. Motion 19-119: Authorize Administrator to submit CRWD’s MS4 Annual Report for 2018 and to reasonably incorporate comments received during the public comment period. Reider/Jones Unanimously approved I)

AR:

Adopt 2019 CRWD Strategic Plan (Fossum)

Mr. Fossum reviewed that in 2008 CRWD completed a strategic planning process with Barbara Deming with MN Management and Budget. In 2018, the district began to develop its next watershed management plan renewing the ten-year-old strategic plan. Mr. Fossum reviewed the comments in the final draft Strategic Plan and the next steps include putting a format to of how the plan will be put into place.


Motion 19-120:

Adopt 2019 CRWD Strategic Plan.

Reider/Sanders Unanimously approved VI.

Unfinished Business A) 2020 Budget Update (Doneux)

Administrator Doneux provided a review of the Operations budget with tax levy actuals from 2017, 18, estimated 2019 and proposed 2020. The proposed 2020 would leave the ending balance of the fund balance less than 50% and using fund balance for the 2020 budget. Additional adjustments will be made. The first preliminary budget meeting is planned in September to take action on the budget. Manager Texer recommended that staff meet with Partners regarding project budgets. Administrator Donuex added that projects may change and there is still additional work to do on the budget. Manager Reider inquired about annual costs continuing to go up. Administrator Doneux replied that CRWD is being invited to participate in more projects. The costs of projects are going up and CRWD is involved in larger sized projects. Administrator Doneux felt that once the June expenses are in, he would have a better handle on predictions for the remaining 2019 expenses. A budget workshop will be planned for July 10th. B) Partner Grant Update (Schwantes) Ms. Bromelkamp provided an update on the Partner Grants for Ms. Schwantes. The review committee has new ideas regarding the application process of reviewing grants for applicants with a long-standing relationship vs. new applicants. At this time the review committee will not be making any major changes. General Information A)

Board of Manager’s Updates

Manager Sanders shared a shout out to staff, regarding Lake McCarron’s. Manager Sanders explained how a Neighbor has underground stream. CRWD staff came out and answered questions for neighbors. Manager Reider shared that she attended the Frogtown Farm festival and found it to be very interesting. VII.

Next Meetings A) Wednesday, July 10, 2019 5:00 PM - Board Workshop - Budget B) Wednesday, July 10, 2019 6:00 PM – Board Meeting C) Wednesday, July 17, 2019 CAC Tour

On Thursday June 27th a monument will be revealed at the Allianz Field. Manager Jones will speak on behalf of CRWD. Manager Texer and Manager Reider will be attending the MAWD summer tour. VIII. Adjournment


Motion 19-121: Adjournment of the June 17, 2019 Regular Board Meeting at 7:15 PM Reider/Jones Unanimously Approved Respectfully submitted, Michelle Sylvander


July 10, 2019 Board Meeting

DATE: TO: FROM: RE:

July 3, 2019 CRWD Board of Managers Britta Belden, Water Resource Project Manager Approve contract for Como Lake Alum Plans and Specifications

V. B. Action Items—Approve Contract for Como Lake Alum Plans and Specifications (Belden)

Background The Como Lake Management Plan (CLMP) was adopted by the Board of Managers on May 15, 2019. The CLMP presents an adaptive management plan framework for achieving water quality goals for Como Lake through in-lake, watershed, and community actions over the next 20 years. As part of the CLMP, an alum treatment was recommended (Action L2) to inactivate sediment phosphorus, which is the most significant source of internal phosphorus loading in the lakw. An alum treatment is a nontoxic method that involves the application of aluminum sulfate to the lake surface by boat. Following application, the alum moves through the water column to the lake bottom where it chemically reacts with the lake bottom sediments to “lock up” phosphorus so it is not available for algae to consume. To determine the amount of alum that needs to be applied to the lake so internal phosphorus loading is most effectively addressed, an alum dosing plan needs to be developed that is based on monitored water column phosphorus concentrations and phosphorus fractions from sediment cores. To develop an alum dosing plan and specification for bidding, CRWD sought a proposal from LimnoTech. LimnoTech was selected because of their significant involvement in calculating internal phosphorus loading in Como Lake in the Como Lake Water Quality Drivers Analysis Study (2017) combined with their extensive experience in developing alum dosing plans, providing bidding assistance, and carrying out alum treatments. Issues Staff have worked with LimnoTech to develop a scope of work, budget, and schedule for the development of alum plans and specifications for Como Lake. Staff recommend approval and will review the proposal with the Managers. Fiscal Note: 2019 CRWD Budget Fund 405-19703: Como In-Lake Management-- $224,600. Requested Action Approve scope of work and budget for development of Como Lake Alum Plans and Specifications; and authorize the Administrator to execute a professional services agreement with LimnoTech for an amount not to exceed $33,710.00. enc:

Proposal to Develop Alum Plans and Specifications for Como Lake from Limnotech, dated 6/27/2019

W:\06 Projects\Como Lake Projects\Alum Treatment - Como Lake\Board & CAC\Brd Memo_LTAlum_SOW-Budget-Sched_7-10-19.docx

Our Mission is to protect, manage and improve the water resources of Capitol Region Watershed District


June 27, 2019

Britta Belden Bob Fossum Capitol Region Watershed District 595 Aldine Street Saint Paul, MN 55104 RE: Proposal to Develop Alum Plans and Specifications for Como Lake Dear Bob and Britta: As requested, this letter proposal includes scope and fees to calculate an alum (aluminum sulfate) dose for Como Lake, develop the specifications and bid documents, provide bidding assistance, public information meeting support and permitting support, and oversight and field support during the alum application. Thank you for the opportunity to submit a proposal to conduct this work for the Capitol Region Watershed District (CRWD). LimnoTech began supporting CRWD's efforts to improve Como Lake in 2016 with the Water Quality Drivers Analysis Study. Through that project, we established a fundamental understanding of the major drivers of water quality in Como Lake, which include continued external loading of phosphorus, high rates of diffusive sediment flux of phosphorus driven by low oxygen conditions, phosphorus release from decaying aquatic plants (primarily curly-leaf pondweed), and an imbalanced aquatic biological community. That understanding created a solid foundation for LimnoTech to continue supporting CRWD with development of the Como Lake Management Plan beginning in 2018. LimnoTech worked closely with CRWD to develop the Como Lake Management Plan, which takes an adaptive approach to the short-term and long-term management of Como Lake. A key component of the planning process involved meeting with agency partners and engaging with the community to identify the major issues facing Como Lake and community goals for the future of the lake, and to develop in-lake, watershed, and community-based actions that will meet those goals. In order to reduce diffusive flux of phosphorus from the sediments, LimnoTech recommended that alum treatment be implemented in the first three years following plan adoption. Alum is a coagulant that is applied to lakes to bind with phosphorus thereby making it unavailable for algae growth and has been shown to reduce sediment phosphorus flux by 85-90%. Combined with our experience with developing alum dose strategies elsewhere, our foundational understanding of the Como Lake Water Quality Drivers Study and the Como Lake Management Plan make us uniquely qualified to calculate the appropriate alum dose for Como Lake, efficiently develop associated documentation and provide related support with the application. Since 1975, LimnoTech has conducted inland lake work all across the country, which includes diagnostics, modeling, regulatory support, restoration and management. Our first experience with alum treatments to inland lakes began in the early 1980s in Michigan, which was led by Dr. Joseph Depinto. Since that time, the science behind alum treatment and design has evolved


Alum Application Plans and Specifications for Como Lake

June 27, 2019

leading to a better understanding of the basis for design. Currently, our alum related work is led by Dr. Dendy Lofton, who is the practice lead for LimnoTech’s Lake & Reservoir Restoration & Management service area. As a Certified Lake Manager through the North American Lake Management Society (NALMS), Dendy has participated in training workshops on alum applications and has a deep, technical understanding of the latest state of the science with regard to alum treatment design and implementation. Dr. Lofton has applied her technical understanding to our most recent alum project in Lake San Marcos (California). Lake San Marcos is a highly valued recreational reservoir in San Marcos, CA with extensive internal and external phosphorus loading. Hypolimnetic total phosphorus concentration has approached 600 µg/L in summer, which is a function of anoxia-driven internal phosphorus loads. LimnoTech and the client group have taken an adaptive management approach to the alum applications given the high in-lake phosphorus and continued watershed loads. Three alum treatments have been applied to the lake to-date, which have significantly lowered the in-lake phosphorus concentration following treatment. In 2018, LimnoTech designed and implemented a pilot study to treat the lake inflows with an alum-based compound (aluminum chlorohydrate, ACH) to intercept the phosphorus prior to entering the lake. The pilot test successfully reduced the external phosphorus load to the lake indicating that a scaled-up permanent system would be an effective management action for Lake San Marcos. Dendy is also currently designing an alum dose strategy for 11 small lakes in the Ibis Lakes Preserve near West Palm Beach, Florida, which will be implemented later this year. Drs. Dilks and Lofton have collected sediment cores for determination of the phosphorus fractionation species that will serve as the basis for the alum application to the sediments. This project is also taking an adaptive management approach. The response of the lakes to the alum treatments will be monitored and assessed over time with the feasibility of an inflow treatment system being a future recommended action for management of the system as a whole. A detailed description of the scope and fees to complete this work is provided below.

Scope of Work The scope of work described in this proposal includes the following tasks: 

Task 1: Develop alum dose and application strategy

Task 2: Develop alum application specifications

Task 3: Bidding Assistance

Task 4: Public Information Meetings

Task 5: Permitting

Task 6: Alum application oversight and monitoring

Activities that will be completed under each task are described below. Task 1: Develop alum dose and application strategy LimnoTech will develop an appropriate alum (aluminum sulfate) dose for Como Lake, which will be informed by existing sediment phosphorus data that was measured in intact sediment cores in Page | 2


Alum Application Plans and Specifications for Como Lake

June 27, 2019

2016. The existing sediment phosphorus data includes labile organic phosphorus, iron-bound phosphorus, aluminum-bound phosphorus, and loosely-bound phosphorus. Recent total phosphorus water column data will also be incorporated into the dose determination. LimnoTech will evaluate whether a buffer will be needed based on pH measurements and alkalinity measurements, which we assume will be collected in summer 2019. LimnoTech will develop a technical memo that summarizes the alum dose analysis and application strategy which will be reviewed and discussed with CRWD prior to developing the technical specifications and bid documents. The information in this technical memo will serve as the basis for the technical specifications and bid documents, which will be developed in Tasks 2 and 3. The technical memo will include recommendations and considerations for the timing of the alum application (e.g. seasonal, suitable pH ranges, etc.) as well as considerations for timing of anticipated herbicide treatments to manage curly-leaf pondweed. LimnoTech has included time and budget under this task for close coordination with CRWD to discuss the plans and finalize the technical memorandum as well as time for participation in one CRWD Board meeting to discuss the alum application plan. Deliverable(s): Draft and final technical memo documenting the alum application plan. Task 2: Develop alum application specifications Based on the final approved alum application plan developed in Task 1, LimnoTech will prepare technical specifications for the alum application, which will include, but not limited to the following critical information:  Background project information  Specified volume of alum based on the dose developed in Task 1, including whether a buffer will be needed.  Locations within the lake (e.g. all or portions of the lake or how the dose may vary with depth as a function of sediment phosphorus)  Timing (i.e. time of the year the alum will be applied)  Equipment requirements (e.g. GPS-linked capabilities for the barge system to ensure high degree of dose specificity and boom structures on the barge that are capable of discharging alum 1-2 inches below the water surface)  Alum delivery and staging (e.g., shoreline location where tanks can be stored with accessibility from the lake for barge to reload and landside accessibility for delivery trucks and staging).  Chemical hazards and steps for risk reduction.  Other necessary details to complete the work by an approved alum applicator, which will be determined as part of this task. Deliverable(s): Alum application project specifications. Task 3: Bidding Assistance Using the information in the alum specifications (Task 2), LimnoTech will develop bid documents to be used for contracting with an alum applicator. LimnoTech will assist CRWD with distribution of the bid documents, answering questions from bidders, reviewing responses, and providing a recommendation for contractor selection. LimnoTech will participate in pre-bid meetings with

Page | 3


Alum Application Plans and Specifications for Como Lake

June 27, 2019

CRWD as needed to make the final determination for a contractor. Bid documents will be signed by a Professional Engineer licensed in Minnesota. Deliverable(s): Bid documents and bidding assistance. Task 4: Public Information Meetings As part of this task, LimnoTech will participate in up to two public information meetings to describe the forthcoming alum treatment and to answer questions. LimnoTech will assist CRWD in preparing presentation materials for the meetings and general coordination for meetings as well as meeting participation. Deliverable(s): Presentation materials Task 5: Permitting Currently, permits are not required to apply alum to lakes in Minnesota. However, the Minnesota Pollution Control Agency (MPCA) does request a letter that explains the overall dose and how many applications are expected. This information will largely be a summary from the technical memo developed in Task 1 and the technical specifications developed in Task 2. As part of Task 3, LimnoTech will develop a letter to summarize the requested information and coordinate with the MPCA to answer any questions regarding the alum application. This task also includes time and budget for close coordination with MPCA and CRWD to fulfill MPCA’s request for a letter. Deliverable(s): Letter to MPCA. Task 6: Alum application oversight and monitoring It is expected that the alum application can be completed within two days, which includes initial set-up and application. LimnoTech will be on location during the initial set-up and during the application to provide oversight and answer contractor questions to ensure progress, record field notes and photos, and monitor pH throughout the process. If more detailed water quality monitoring is warranted before, during or after the alum application, LimnoTech will provide guidance to CRWD on water quality sampling needs. In that case, LimnoTech assumes that CRWD staff will be able to assist with water quality sampling beyond pH monitoring. LimnoTech also assumes that CRWD will lead coordination and scheduling with the alum contractor. Deliverable(s): Contractor oversight, field notes, and photo documentation.

Page | 4


Alum Application Plans and Specifications for Como Lake

June 27, 2019

Schedule Work will be completed under the estimated schedule presented in Table 1. Table 1. Project Schedule Task

Estimated Schedule

Task 1. Alum dose plan and application strategy

Summer 2019

Task 2. Develop alum application specifications.

Summer 2019

Task 3. Bidding assistance. Task 4. Public information meetings. Task 5. Permitting Task 6. Alum application oversight and monitoring

Fall 2019 Winter 2020 Fall 2019 Spring 2020

Budget The total cost to complete the above tasks is estimated to be $33,710, which includes anticipated labor and direct expenses (Table 2). Direct expenses include field supplies and equipment expenses.

Page | 5


Alum Application Plans and Specifications for Como Lake

June 27, 2019

Table 2. Proposed Budget

Task

Task Description

Dilks Holmberg Lofton Crary Grewe $210

Task 1 Task 2 Task 3 Task 4 Task 5 Task 6

Alum dose determination Develop alum application specifications Bidding assistance Public information meetings Permitting Alum application oversight and monitoring Total

4 4

8

$195

4 4

8

$150

$120

40 24 16 8 6 24 118

8 32 32 4 5 81

Labor Fees

$100

8 8

12 28

$7,800 $9,860 $7,820 $1,680 $1,500 $4,800 $33,460

Direct Expenses (e.g., field supplies, field equipment)

$250 $250

Total Cost

$7,800 $9,860 $7,820 $1,680 $1,500 $5,050 $33,710

Page | 6


Alum Application Plans and Specifications for Como Lake

June 27, 2019

Please let us know if you have any questions regarding this proposed scope of work. We appreciate the opportunity to continue supporting CRWD’s efforts to improve Como Lake. Sincerely, LimnoTech

Hans Holmberg, P.E. Associate Vice President Senior Engineer

Dendy Lofton, PhD, CLM Project Manager/Limnologist Certified Lake Manager

Page | 7


July 10, 2019 Board Meeting V. C) Action Item – Approve Stewardship Grant Calculator – Equity Bonus (Eleria / Novak)

DATE: TO: FROM: RE:

July 2, 2019 CRWD Board of Managers Andrew Novak, Urban BMP Specialist Approve Stewardship Grant Calculator – Equity Bonus

Background Capitol Region Watershed District’s MN GreenCorps Member presented the Stewardship Grant Project Assessment in July of 2018. The report presented calculated pollution reductions of the program, locations of program participants, and analysis of the program’s success. With the information compiled in the report, staff have been able to ascertain the geographic reach of the program, locate gaps in service, and begin the process of developing strategies for implementing projects in areas of need. Issues Through analysis of the Stewardship Grant program, staff have observed striking disparity in project participation within several areas of CRWD. These disparities overlap with several key demographics including concentrations of poverty and large percentage of people of color. Our Stewardship Grant program has been very successful in areas with high numbers of affluent, highly educated white residents but has clear gaps of service in historically underrepresented neighborhoods with higher numbers of people of color. As a first step to increase diversity of project participants and to promote services provided through the CRWD Stewardship Grant program, staff recommend applying a Stewardship Grant Equity Bonus in the following Saint Paul District Councils: North End Neighborhood Organization, Payne-Phalen Planning Council, Frogtown Neighborhood Association and Dayton’s Bluff Community Council. The suggested Equity Bonus is a 50% grant award bonus as part of our existing Stewardship Grant Calculator and reduction in match requirements. Enclosed is a technical memo summarizing the program analysis conducted to determine the grant calculator bonus and target areas for applying the bonus. Staff will be coordinating a focused promotional effort with target District Councils and attend area community events this summer and fall to build relationships with residents and community leaders. Action Requested Approve the Stewardship Grant Calculator – Equity Bonus enc:

CRWD Technical Memo – Stewardship Grant Calculator Equity Bonus dated July 2, 2019

\\crwd01-dc01\company\07 Programs\Planning Projects Grants Division\Andrew\Equity, Environmental Justice and Sustainability\Tech Memo\BM-CRWD Equity Bonus AE AN-REV.docx

Our Mission is to protect, manage and improve the water resources of Capitol Region Watershed District.


DATE: TO: FROM: RE:

July 2, 2019 CRWD Board of Managers and Staff Andrew Novak, Urban BMP Specialist Stewardship Grant Calculator – Equity Bonus Technical Memo

Background Capitol Region Watershed District’s (CRWD) Stewardship Grant Program provides homeowners, institutional organizations, and businesses with financial and technical assistance to build water quality improvement best management practices (BMPs) that protect and improve water resources in the District. Between 2005-2018 the District has provided technical assistance for 312 participants. Of that number, 185 have received funding to implement a project. To date, Stewardship Grant projects capture an estimated 17 million gallons of runoff and prevent 52 pounds of phosphorous and 15,000 pounds of sediment from polluting local water resources. Issues In July 2018, CRWD’s MN GreenCorps Member presented the Stewardship Grant Program Assessment Report. The purpose of the report was to present the calculated pollution reduction of the program, locations of the program participants, and share analysis of the program’s success. With the information compiled for this report, staff are better able to ascertain the geographic reach of the program throughout CRWD, locate gaps in service, and begin the process of developing strategies for implementing projects in areas of need. The number of projects per square mile (PSM) was calculated for each subwatershed and can be used to identify areas throughout CRWD that may benefit from targeted promotion of the Stewardship Grant Program to increase participation. Sub-watersheds that fall below the median 4.03 PSM are shown on Figure A – Subwatersheds with Low Projects per Square Mile. Figure A – Subwatersheds with Low Projects per Square Mile


The results show the eight sub-watersheds with the lowest number of participants. The top two lowest sub-watersheds have very few opportunities because of landcover type, ownership and/or size will not allow for projects. Also, of note is the Downtown subwatershed, coming in as the fourth lowest PSM and has very few opportunities because of the high- density of development. For reasons we will discuss further, the subwatersheds of most interest are Trout Brook and Phalen Creek which have many opportunities, but very few project participants. On February 2, 2018, a Stewardship Grant survey was mailed to all program participants with rain gardens. The survey was designed to gain a better understanding of our project participants regarding their experience with the Stewardship Grant program and their behaviors regarding the required maintenance commitment. Four optional demographic questions at the end of the survey were used to collect data regarding age, education, race/ethnicity, and annual household income. 222 surveys were mailed, and 82 participants responded (37% response rate). Of the respondents that answered all four demographic questions, most were older, white, wealthy and highly educated (Table 1). Table 1. Stewardship Grantee Demographics

Q12: What is your age? Q13: Highest level of education completed or current.

Answer

Count

%

55-64 years

24

30.00%

48

61.54%

Advanced education beyond Bachelor's

Q14: Race and/or Ethnicity

White

64

90.14%

Q15: Annual household income, before taxes

$125,000 or more

17

26.15%

In response to this apparent lack of diversity amongst participating survey respondents, CRWD staff compared demographic data provided by the Metropolitan Council with the District’s areas of low PSM. The Met Council datasets of interest are the Areas of Concentrated Poverty and Percent People of Color. A commonly used aggregate of these two datasets is referred to as the Areas of Racially Concentrated Poverty With 50% or Greater Residents of Color (ACP 50). Staff observed a striking overlap between areas of low PSM and the ACP50, particularly within the Trout Brook and Phalen Creek sub-watersheds (Figure B – Map of ACP 50 with CRWD Subwatersheds and District Councils). This observation is further supported by our survey results showing most of our program participants are older, white, wealthy and highly educated. Because CRWD’s mission is to protect, manage and improve water resources throughout the District it is imperative that efforts are made to both increase program participation in areas with few Stewardship Grant projects and attract participants who have been historically Our mission is to protect, manage and improve the water resources of Capitol Region Watershed District.


underrepresented in the program. This directive is further supported by the implementation of the CRWD 2018-2020 Diversity Strategic Plan which calls for actionable steps to expand the reach of our programming and deepen relationships with underserved communities throughout CRWD. Recommendations To increase diversity of project participants and promote equitable access to services provided through the CRWD Stewardship Grant program, staff recommend implementing a Stewardship Grant Equity Bonus. The bonus is a 50% grant award bonus as part of our existing Stewardship Grant Calculator. This Equity Bonus would function like the current Education and Visibility Bonus. These bonuses are based on a percentage of the base award generated by the Grant Calculator which calculates award amounts based on the water quality benefit of the proposed project. Staff also proposes adjustments to the minimum match requirements as follows: 0% for residential (currently 5%), 5% for nonprofit (no change), 10% for businesses (currently 25%). See Table 2 for proposed match requirements. The proposed total grant award with an equity bonus and revised minimum match requirements cannot exceed the CRWD cost estimate for the project. To illustrate the effects of the Equity Bonus, an example of grant award adjustments has been produced by applying the bonus to 2018 Stewardship Grant projects as seen in Table 3 – Equity Bonus Sample Adjustments. Please note that not all projects listed in the table fall within the bonus area. Staff is working to develop a course of action for promoting the Stewardship Grant Program in underserved areas. We have concluded that the District Councils located in the areas of concern could provide a great deal of social capital towards promotion of our Stewardship Grant program. Therefore, it is proposed that promotion be focused within these four targeted St. Paul District Councils – Frogtown, North End Neighborhood Organization, Payne-Phalen, and Figure B. CRWD Subwatersheds with Low PSM, Dayton’s Bluff. These four District District Councils and ACP50 Councils overlap with CRWD subwatersheds of low PSM as well as the geographic boundary of the ACP 50 (Figure B).


Developing an engagement strategy for these promotional initiatives is a partnership between the Planning, Projects, and Grants Division and the Communications and Engagement Division of CRWD. Upon approval of the Equity Bonus as outlined within this Technical Memo, staff will coordinate District Council meetings with the District Council Executive Directors to share our grant programs and our interest in improving our promotional efforts within their communities. We will attend District Council meetings when possible and ask for input from District Council members regarding best practices for better reaching their constituencies We will discuss the issues presented within this Tech Memo and our desire to better reach areas of CRWD currently underserved by our services. Staff is also planning to incorporate promotion of our Stewardship Grant program for residents at scheduled community events within these four District Councils. Table 2. Proposed Minimum Match Requirements Property Owner Type Residential Non-Profit Business

Current Match Requirements 5% 5% 25%

Proposed Match Requirements 0% 5% 10%

Table 3. Equity Bonus Sample Adjustments

Grant Project Rondo Commemorative Plaza Common Bond Communities First Lutheran Church 1410 Energy Park Dr Bang Brewing Frogtown Farm Gloria Dei Lutheran Church 'A' Gloria Dei Lutheran Church 'B' Western Sculpture Park

Cost Estimate

Current Award

Proposed Equity Bonus

Proposed Total Grant Award w/Equity Bonus and New Match Reqs.

$ 37,684 $ 34,809 $ 14,760 $ 62,300 $ 16,537 $ 83,430

$ 31,722 $ 18,006 $ 7,204 $ 46,725 $ 5,725 $ 26,194

$ 15,861 $ 9,003 $ 3,602 $ 23,363 $ 2,863 $ 13,097

$ 35,800 $ 25,659 $ 10,266 $ 56,070 $ 7,729 $ 37,326

$ 59,300

$ 6,009

$ 3,005

$ 8,563

$ 75,500 $ 7,820

$ 71,725 $ 5,030

$ 35,863 $ 2,515

$ 71,725 $ 7,168


July 10, 2019 VI. A. 2020 Work Plan and Budget Update (Doneux)

DATE: TO: FROM: RE:

July 2, 2019 CRWD Board of Managers Mark Doneux, Administrator 2020 Work Plan and Budget Update

Background The Board of Managers reviewed the preliminary 2020 Work Plan along with the Budget at a Board workshop on June 5th, 2019. Issues The Board of Managers must establish a plan of work for the upcoming year, establish a budget based upon the work plan, and establish a levy for the budget. Staff will review the draft budget (project list) with the Board of Managers. We will also review the revenue and levy summary and also review the “Road Map to a Balanced Budget.�

Request Action For information only. enc:

Project List (also referred to as budget or work plan) Revenue and Levy Summary Road Map to a Balanced Budget

W:\02 Budget and Finance\Budget - 2020\BD Memo 2020 Work Plan and Budget Update.docx

Our Mission is to protect, manage and improve the water resources of Capitol Region Watershed District.


2019 Capitol Region Watershed Budget

Preliminary 2020 Budget

Final 2019 Budget

July 2, 2019

Fund # Fund Name

Project #

Project Name

101-19970 101-19975 101-19976 101-19978

General Administration 595 Aldine Operations 1736 Thomas Operations MAWD Administrative Allocation

Priority / Comment

2019 Project Budget

Project Description

2020 Project Budget

2019 Fund Total

2020 Fund Total

Change

%

ADMINISTRATION

101

Administration

Critical Critical Critical Beneficial Ongoing

General Admin. of Operations for CRWD General Operations for 595 Aldine General Operations for 1736 Thomas Provide support to MAWD Annual Cost Allocation to Project and Programs

$

660,840 61,200 5,000 (289,200)

$ $ $ $ $ $

437,840

$

6,480

972,200 64,000 51,000 10,000 (450,000)

$ 209,360

$

647,200

$

7,000

$

$

10,000

$

(12,300)

$

400,000

$

1,410

$

610,000

$ (209,880)

$

648,000

$

48%

PROGRAMS 201

Groundwater

207

Rulemaking/Rule Revisions

201-19130

Permitting

Beneficial

Provide grant reimbursements for well sealing Conduct TAC process to update Rules

$

6,480

207-19120

Evaluate Rules Hold TAC Meetings

Critical

208-19000

Critical Critical

Continue Implementing District Permit Program Track and Manage Database for Permit Program

208-19102 208-19103

District Permit Program Permit Tracking and Database Management Construction Inspection Closure & Post Construction Inspection

Critical Critical

Inspect active permits sites for compliance Inspect completed permit projects for compliance and maintenance

210-19143 210-19144 210-18145 210-18146 210-16147 210-19148

Stewardship Grants Partner Grants Inspiring Communities Program SPS Rain Garden Projects TWP - Blvd Rain Gardens MN Greencorps Member

Important Important Important Important Critical Important

Administer, promote, and outreach on Stewardship Grants Provide Grants to Partners for Ed/Outreach Programming Provide design & projects funds for City ICP Program Assist Blvd raingardens as part of City's Street Reconstruction Program Assist with Boulevard Rain Gardens in Como and McCarron's Subw. Support MN Greencorps member

$

427,650 126,340 20,490 24,090 213,310 8,000

Stewardship Grants

211-19200 211-19205 211-19210 211-19215 211-19220 211-19225 211-19230 211-15231 211-17232

Baseline Monitoring & Data Collection Lake Monitoring & Data Collection Villa Park Monitoring & Data Collection Wetland Bio-Monitoring WISKI Database & Website Remote Data Access & Set Up BMP Monitoring Upper Villa Exfiltration Monitoring Midway Office Warehouse Monitorng

Critical Critical Critical Important Critical Important Important Beneficial Important

Monitoring of stormwater baseline, water level and rain gauge sites Monitor 5 lakes for chemical, biological and qualitative parameters 2 FWQ sites in Villa Park, 2 level loggers, Lake McCarrons flow only Monitor wetlands, IBI assessments, wq & data analysis Long term monitoring database for effective data management Implement Remote Data Access Program Monitor BMP sites-Como 7, CCLRT, Upper Villa Exfiltration Monitoring of an Underground Infiltration BMP Monitoring at Midway Office Warehouse

$

331,880 102,610 28,470 17,670 46,720 12,510 49,540 18,560 29,810

Monitoring and Data Collection

10,000

202,640

$

200,000

14,150 147,250 34,550

$ $ $

15,000 150,000 35,000

$ $ $ $ $ $

425,000 130,000 20,000 20,000 15,000 -

$ $ $ $ $ $ $ $ $

330,000 105,000 30,000 18,000 50,000 15,000 50,000 20,000 30,000

$

Page 1

$

$

$

211

7,000

22,300

$

210

$

$

$ 208-19101

208

Groundwater Protection - Well Sealing

22,300

398,590

819,880

637,770

520

10,230

8%

-55%

0%

-26%

2%


2019 Capitol Region Watershed Budget

Preliminary 2020 Budget

Final 2019 Budget

July 2, 2019

Fund # Fund Name

220

Education and Outreach

225

Technical Resources and Information Sharing

Project #

Project Name

220-19250 220-19255 220-19260 220-19270 220-19271 220-19265 220-19275 220-19285 220-19262 220-19263 220-19268 220-17274 220-16277 220-16278 220-19279 220-19280

General Outreach and Communication Leaf & Litter Clean Ups Municipal Training Website Master Water Stewards Sponsorships and Partnerships Events Awards Program Youth Outreach Communication Training Adopt a Drain TWP Communiations TWP - Adopt a Drain TWP - Leaf & Litter Clean Ups Social Media 595 Aldine Education and Outreach

225-19300 225-19303

Plan Review & Tech Committee BMP Database

228-19330 228-19333 228-18334 228-19335

District Research Program Public Art Program 595 Aldine Art Diversity & Inclusion Climate Change Impacts-Research and Action

Priority / Comment Critical Critical Important Important Important Beneficial Beneficial Important Important Important Beneficial Important Critical Critical Important Important

2019 Project Budget

Project Description Provide general Outreach and Communication for the District Implement a Leaf and Litter Clean Up Program Provide training for municipal staff Maintain and provide content for CRWD website Implement Master Water Stewards Program Sponsor and support partner organizations Community and CRWD-sponsored events and activities Support CRWD Recognition Program Develop and Implement Outreach Prgramming to District Youth Provide communication training for staff, board and partners Promote and implement Adopt A Drain Program Implement communications to support TWP Promote/implement Adopt a Drain in Como and McCarrons subwatersheds Leaf and Litter Clean Ups in Como & McCarrons Subw for TWP Maintain and update District Social Media accounts Provide for Education and Outreach at 595 Aldine

$

270,690 10,370 14,740 37,730 30,410 28,040 35,720 14,950 10,640 10,990 21,360 6,980 5,370 6,370 7,260 100,000

Review plans and serve on committees as appropriate Update and maintain BMP Database

$

17,000 15,680

Important Important Beneficial Important

Develop and Implement Comprehensive Research Program Work with watershed artist on District public art projects Create and install art in CRWD's new office Implement CRWD Diversity & Inclusion Plan

$

50,200 29,120 25,960 20,000

Important

Research Climate Change impacts on design Standards (Atlas--14)

$

228

Future Trends: Research and Positioning

Critical Critical

$

228-19336

240

Geographic Information Systems Safety Program

230-19370

GIS Program Development

240-19390 240-19395 240-19396

Safety Training Safety Program Updates Safety Equipment

Important

Manage GIS needs for CRWD

$

50,390

Provide Safety training for staff Update safety program, protocols, procedures, and equipment Purchase, maintain and repair Safety Equipment

$

13,540 12,400 12,520

Administrative Allocation

$

-

$ Critical Critical Critical

PROGRAMS TOTAL

Page 2

$ $ $ $ $ $ $ $ $ $ $ $ $ $ $ $

244,000 10,500 14,200 25,000 30,410 29,040 15,000 14,950 10,640 10,990 18,360 6,980 5,370 6,370 14,210 85,000

$ $

15,000 50,000

$ $ $ $

50,000 30,000 10,000 10,000

$

20,000

$

50,000

$ $ $

15,000 13,000 13,000

$

297,000

611,620

32,680

19,800 $

230

2020 Project Budget

2019 Fund Total

145,080 50,390

$ $

38,460 190,872

$

2,954,122

2020 Fund Total

Change

%

$

541,020

$

(70,600)

-12%

$

65,000

$

32,320

99%

$

120,000

$

(25,080)

-17%

$

50,000

$

(390)

-1%

$ $

41,000 297,000

$ $

$

2,789,020

2,540 106,128

$ (165,102)

7% 56%

-6%


2019 Capitol Region Watershed Budget

Preliminary 2020 Budget

Final 2019 Budget

July 2, 2019

Fund # Fund Name

Project #

Project Name

301-19405

St. Paul Natural Resources Intern Program

Priority / Comment

2019 Project Budget

Project Description

2020 Project Budget

2019 Fund Total

2020 Fund Total

Change

%

PROJECTS 301

Shoreline & Streambank Maintenance

Como Lake Subwatershed

Sponser intern with St. Paul for BMP maintenance or other activities

8,000

$

8,000

26,070 9,500

$ $

26,000 10,000

23,920 42,920 -

$ $ $ $ $

40,000 20,000 15,000

$ $ $ $ $

15,000 10,000 30,000 10,000 5,000

$

50,000

100,500

$

180,000

216,000 7,910 20,000 -

$ $ $ $

150,000 10,000 20,000 50,000

$

30,000

$ 305-19421 305-19425

305

Important

Como BMP Maintenance Curtiss Pond Opti RTC O&M

Critical Important

Conduct inspection and maintenance of Como subwatershed BMPs Operate, Maintain and Inspect Opti RTC System

305-16430

TWP - Como Lake Project Development

Critical

305-18427 305-19428 305-19429 305-20xxx

Como Lake Management Plan Como Lake Aquatic Plant Management Como Lake Shoreline Management Como Golf BMP O & M

Important

Develop Como Lake Management Plan

Develop Projects for the Como Lake TWP

310-19470 310-19477 310-18476 310-20xxx 310-20xxx

AIS Mgt Lake McCarrons Management Plan Upper Villa Maintenance Parkview O & M Williams Street Pond O & M

Beneficial Important Critical Critical

Manage Aquatic Invasive Plants Develop a Lake McCarrons Mgt Plan Upper Villa Maintenance 0

$

313-20xxx

Willow Reserve Management

Critical

Planning for the protection and restoration of Willow Reserve in St. Paul

$

315-19550

Critical

Manage, operate, inspect, maintain, and repair TBI

$

315-19570 315-18575 315-20xxx

TBI Inspection and Maintenance TBI Easement Verification & Documentation NPDES MS4 Stormwater Program Illicit Discharge Detection & Elimination Subwatershed Study

317-19631

Highland Ravine BMP Maintenance

$

310

Lake McCarron's Subwatershed

Trout Brook Subwatershed

Critical Critical Important Completed

Conduct TBI easement verification, acquisition and documentation work Implement MS4 SWPP Implement IDDE program Conduct Subwatershed Study on TBI East Branch

$

325

$

8,000

$

-

0%

$

111,000

$

8,590

8%

$

70,000

$

50,000

$

410,000

$

65,590

19%

$

30,000

$

1,290

4%

$

380,000

$

123,880

48%

$

150,000

$

(92,180)

-38%

$ $

100,000 153,000

$ $

12,680 54,672

15% 56%

$

1,462,000

$

92,822

7%

$ (131,700)

-65%

Loeb Lake Subwatershed

315-14552

317

201,700

$

315

102,410

39,300 132,400 30,000 $

313

8,000

Crosby Lake Subwatershed Wetland, Stream, and Ecosystem

Mississippi River Subwatershed

370

Watershed Management Planning

390

Special Projects and Grants

Maintain Gully Stabilization BMPs

330-19621 330-18622 330-19624 330-18623 XXX-XXXXX

Green Infrastructure for Innovation Districts Snelling Midway Redevelopment Ford Site Planning Green Line BMP Maintenance Ford Site - Area C Snelling Midway Redevelopment O & M

Critical Critical Important Critical Important

Planning for green infrastructure in innovation districts

2020 Watershed Management Plan

390-19660

Special Grants - Project Development

Critical

Prepare and adopt 2020 WMP

$

242,180

Support feasibility studies by special grant partners

$

87,320

$ Important

28,710 -

60,800 29,750 119,200 36,370 10,000 -

Develop maintenance agreement and conduct maintenance of BMPs Provide Design and Planning Assistance for Former Ford Site Inspect and maintain the Green Line BMPs Plan Review and Comment on Area C

$ 370-18650

344,410

28,710 $ $

330-19620

330

Critical

-

75,000 45,000 150,000 35,000 25,000 50,000

$

150,000

$

100,000

$

153,000

256,120 242,180

Administrative Allocation

$ $

87,320 98,328

PROJECTS TOTAL

$

1,369,178

Page 3

$ $ $ $ $ $


2019 Capitol Region Watershed Budget

Preliminary 2020 Budget

Final 2019 Budget

July 2, 2019

Fund # Fund Name 401

Shoreline and Streambank Restoration

405

Como Lake BMP's

410

Lake McCarron's BMP's

2019 Project Budget

Priority / Comment

Project #

Project Name

Project Description CAPITAL IMPROVEMENT PROJECTS

405-19703 405-16705 405-20xxx

Como Lake In-Lake Management TWP - Como BMPs Future Como BMP Engineering

Critical Critical

Plan & Implement In-Lake Project(s) Design and construct stormwater BMPs in Como subwatershed

224,600 947,600 -

410-16752

TWP-McCarrons BMP - Parkview

Critical

Design/Construction of Parkview Elementary BMP

742,320

413-19790 413-16720

Loeb Lake Shoreline Restoration Willow Reserve Restoration Project

415-19820

TBI Repair - Station TBD

$

$

413

Loeb Lake BMP's

415

Trout Brook BMP's

417

Crosby Lake BMP's

425

Wetland, Stream, and Ecosystem Restoration

$ Beneficial Critical

Restore shoreline of Loeb Lake Conduct Restoration work at Willow Reserve

$

430

Mississippi River Subwatersheds BMP's

Engineering Design for next segment of TBI Repairs

425-19850

Land Conservation Funding

Important

Provide resources for Land Protection Initiatives

430-16881 430--15883 430-19890

Important Important Beneficial

Construction of Snelling Midway SSGI practices Design and Implement Stormwater Retrofits as part of CWF Project Support for Green Infrastructure at Midway Peace Park

Important

Complete design and conduct bidding for Seminary Pond improvements

430-20xxx 430-20xxx

Snelling Midway Redevelopment East Kittsondale Stormwater Retrofits Midway Peace Park Lauderdale Stormwater Improvement Project Ford Site Science Museum

440-19910 440-16920 440-19913 440-20xxx

Special Grants TWP - Grant Administration CRWD Opportunity Fund CRWD Long Term Fund (103B.241)

Critical Critical Important Critical

Implement Special Grant Program Administer TWP Grant Program Support CRWD Watershed Management Plan projects Support Long Term CIP Implementation or Debt Reduction

$

366,900 2,880 350,000 -

450-16950

New Office Facility

Critical

Complete buildout of 595 Aldine Office

$

175,000

490-14960

Debt & Loan Service

Critical

Annual Payments for Bonds and Loan (Debt Service)

$

1,059,503

$

430-16886

Special Projects and Grants

450

Future Trends: Implementation

490

Debt Service

BUDGET SUMMARY

13,000 -

$

50,000

82,980 110,000 $

30,000

30,000

$

20,000

51,000 -

$ $ $

500,000 750,000 75,000

$ $ $ $

400,000 5,000 350,000 920,000

$

50,000

834,090

719,780 175,000

Change

%

$

750,000

$ (422,200)

$

700,000

$

(42,320)

-6%

$

13,000

$

(69,980)

-84%

$

50,000

$

(60,000)

-55%

$

30,000

$

-

$

1,345,000

$

510,910

61%

$

1,675,000

$

955,220

133%

$

50,000

$ (125,000)

-36%

0%

-71%

$ 1,060,000 $

1,059,503

$

1,060,000

$

4,925,873

$

5,673,000

2019 Fund Total

ADMINISTRATION PROGRAMS PROJECTS

$ $

-

$

Fund

700,000

$

$

CAPITOL IMPROVEMENT PROGRAM TOTAL

$

603,090 180,000

$

440

350,000 250,000 150,000

742,320

30,000 $

$ $ $ 1,172,200

110,000 $ $

2020 Fund Total

-

12,620 70,360 $

Critical

2020 Project Budget

2019 Fund Total

$

497

0%

$ 747,127

15%

2020 Fund Total

Change

%

$ 437,840 $ 2,954,122 $ 1,369,178

$

647,200

$

2,789,020

$ (165,102)

$

1,462,000

$

92,822

7%

$ 4,761,140

$

4,898,220

$

137,080

3%

CAPITOL IMPROVEMENT PROGRAM

$ 4,925,873

$

5,673,000

$

747,127

15%

TOTAL 2019 BUDGET

$ 9,687,013

$

10,571,220

$

884,207

9%

OPERATIONS TOTAL

Page 4

$

209,360

48% -6%


2020 CRWD Expenditure, Revenue and Levy Summary 7/2/2019 Operations and Capital

OPERATIONS 2017 Actual

OPERATIONS

Revenue

Expenditures

Fund Balance

2018 Actual

2019 Estimated

Tax Levy (1) Intergovernmental (MVHC) Fees Interest Income Other Total

$ $ $ $ $ $

3,112,860 62,581 41,700 17,827 15,407 3,250,375

$ $ $ $ $ $

3,504,968 26,605 27,400 55,756 29,159 3,643,888

$

Administration Programs Projects Total

$

$

$

625,386 1,787,083 679,364 3,091,833

$ $

Beginning Balance Ending Balance

(2)

2020 Proposed $

$

3,530,000 45,000 20,000 1,000 3,596,000

$

3,530,000 125,000 20,000 1,000 3,676,000

$

0.00%

$

(1,222,220)

$

658,516 2,247,976 596,878 3,503,370

$ $ $ $

638,595 2,006,318 783,326 3,428,239

$ $ $ $

647,200 2,789,020 1,462,000 4,898,220

50% of Budget $2,449,110

1,912,725

$

2,071,267

$

2,211,785

$

2,379,546

not ok

2,071,267 ok

$

2,211,785 ok

$

2,379,546 ok

$

1,157,326 not ok

CAPITAL 2017 Actual Revenue

Property Tax Levy (1) Intergovernmental (MVHC) Other Bond Proceeds

$

1,742,958

$

57,533

2018 Actual $ $

2019 Estimated

2,978,321 431,612

$3,525,479 $

0.00%

$9,997,239

Villa Park Wetland Partner Funding (3) Thomas Property Sale Deed Grant Met Council/MNDOT (TBI) MPCA Loan - Villa Park Wetland (4) McCarrons Subw - Upper Villa Grants (5) CAPITAL

2020 Proposed

$3,525,479

$200,000

McCarrons Subw - Upper Villa Partner Funding (6) CWL - Highland Ravine (7) Como Subwater 7 Partner Funding (8) Clean Water Grant - East Kittsondale Met Council Stormwater Improvement Grant Clean Water Grant - Central High School Other - Clean Water Grant (9) Targeted Watershed Program Grant Stormwater Impact Fund Interest Income Fund Balance Total $

1,899,253

Capital Improvement Program

4,132,370

$500,000 $100,000 $87,500 $700,000 $11,262

$128,915 $

13,536,087

$100,000 $

3,925,479

$

$50,000 $0 4,775,479 $

(897,521)

Expenditures 9,706,602

3,965,834

5,673,000

Total

$

4,132,370

$

9,706,602

$

3,965,834

$

5,673,000

Beginning Balance

$

3,458,551

$

1,225,434

$

5,054,919

$

5,014,564

Ending Balance

$

1,225,434

$

5,054,919

$

5,014,564

$

4,117,043

Fund Balance (unencumbered)

7/2/20194:43 PM


2020 CRWD Expenditure, Revenue and Levy Summary 07/02/19 Combined Operations and CIP

Combined Operations and CIP Budget 2017 Actual 2018 Actual Revenues

Expenditures

Fund Balance

Property Tax Levy (1) $ Bond Proceeds Partner Funding Met Council Intergovernmental Fees Other Other - Clean Water G Interest Income Fund Balance Total $

4,855,818 -

Administration $ Programs Projects Capital Improvement Total $ Beginning Balance Ending Balance (2)

Historical Adopted Levy Increase Debt Levy General Levy Total Levy

6,483,289 9,997,239

2019 Estimated $

458,217 27,400 29,159 184,671 $

17,179,975

$

625,386 1,787,083 679,364 4,132,370 7,224,203

$

$

$

658,516 2,247,976 596,878 9,706,602 13,209,972

$

5,371,276

$

$

3,296,701

$

TAX LEVY Operations Capital Improvement Total Difference from previous year % Change

62,581 41,700 72,940 87,500 29,089 5,149,628

$

2017 Actual $ $

3,112,860 $ 1,742,958 $ $4,855,818 $588,047 13.78% 15.18%

7,055,479 97,000 200,000 45,000 20,000 100,000 101,000 7,618,479

2020 Budget $

$

7,055,479 500,000 125,000 20,000 700,000 51,000 8,451,479

$

8,451,479

$

10,571,220

$

(2,119,741)

$

$

638,595 2,006,318 783,326 3,965,834 7,394,073

$

647,200 2,789,020 1,462,000 5,673,000 10,571,220

3,296,701

$

7,266,704

$

7,394,110

7,266,704

$

7,394,110

$

5,274,369

2018 Actual

2019 Estimated

3,504,968 $ 2,978,321 $6,483,289 $ $2,215,518 $ 51.91% 15.18%

2020 Budget

3,530,000 $ 3,525,479 7,055,479 $ 572,190 $ 8.83% 8.83%

$ $ $

1,059,503 5,995,976 7,055,479

3,530,000 3,525,479 7,055,479 0.00% 0.00%

$ $ $

1,060,000 5,995,479 7,055,479

Note (1) The Property Tax Levy is based on actual or projected property tax collections. The Tax Levy section Note (2) Not Used Note (3) Partner Funding - Villa Park Wetland from Projects Partners, $321,364 (2014) Note (4) MPCA Loan for Villa Park Project Note (5) McCarron's Subw - Upper Villa -CWP -MPCA-total grant $275,000. $110,000 received in 2012. Note (5) ( ) McCarron's Subw g - yUpper Villa -Clean g Water Legacy Grant from BWSR-total grant $360,000. substantially complete in 2015, $15,000 when complete and certified. Note (8) Final Partner Funding Curtis FieldLegacy (Pond)Grant Improvements, estimated to be $200,000 in 2014. Note (9) Payment offor Clean Water from BWSR for Central Corridor BMPs to be received in 2013 Note (10) Fund Transfer of BWSR CCLRT Grant of $598,500 from Operations to Capitol The CIP Fund Balance includes the Boulevard Restoration Fund with a $10,000 balance. Current year Fund Balance based on mid year revenue and expenditure estimates

Aug

7/2/20194:43 PM


Capitol Region Watershed District Road Map to a Balanced Budget for 2020 Budget 7/2/2019

Operations

CIP

Total

Revenue

$

3,676,000

$

4,775,479 $

8,451,479

Expenditures

$

4,898,220

$

5,673,000 $

10,571,220

Net

$

(1,222,220) $

(897,521) $

(2,119,741)

OPTIONS Reduce Expenditures Use Fund Balance Raise Levy % Increase

$ $ $

350,000 $ $ 872,220 $ 24%

50,000 $ 847,521 $ $ 0%

400,000 847,521 872,220 12%

Net

$

Fund Balance January 1, 2020

1,222,220

Operations

$

897,521

CIP

$

-

Total

$

2,379,546

$

5,014,564 $

7,394,110

Policy

$

2,449,110 not ok

$

2,000,000 $ ok

4,449,110

2020 Fund Balance Usage

$

$

(847,521) $

Expenditure cuts + Levy

$

1,222,220

$

50,000

$

1,272,220

December 31, 2020

$

2,379,546 ok

$

4,217,043 $ ok

6,596,589

-

(847,521)


DATE: TO: FROM: RE:

July 2, 2019 CRWD Board of Managers and Staff Mark Doneux, Administrator June 2019 Administrator’s Report

1) Administrator Approved or Executed Agreements a) Stewardship Grant Agreement with Joab Meyer for BMP project for an amount not to exceed $1,530. b) Stewardship grant Agreement with Cari Ness Nesje for BMP project for an amount not to exceed $1,060. c) Stewardship Grant Agreement with Ioana Stoian for BMP project for an amount not to exceed $2,245. d) Consultant Services Agreement with Lindsey Diversity Consulting Services for an amount not to exceed $2,250. e) Consultant Services Agreement with Houston Engineering for 2019 BMP database for an amount not to exceed $18,368. f) Consultant Services Agreement with Barr Engineering for Como Sr. High Signage for an amount not to exceed $6,500. g) Consultant Services Agreement with Adopt a Drain for an amount not to exceed $11,019.88. h) Consultant Services Agreement with Wenck Associates for Gortner Ave Feasibility Study for an amount not to exceed $17,450. i) Consultant Services Agreement with StoryTeller for an amount not to exceed $5,665. j) Construction Services Agreement with Witzel Electric, LLC for Bruce Vento Nature Sanctuary Tench Project for an amount not to exceed $3,570. k) Construction Services Agreement with Rachel Contracting for Parkview ESC Maintenance for an amount not to exceed $8,000. 2) Board Approved Agreements a) Water Quality Capital Improvement Project Grant Agreement for North West University and Dale Redevelopment for an amount not to exceed $135,000 b) Consultant Services Agreement Amendment with SRF Consulting for Parkview Center School for an amount not to exceed $67,560. c) Construction Services Agreement with CRWD Pocket Park Interactive Exhibit for an amount not to exceed $39,120. d) Consultant Services Agreement Amendment with AES for Willow Reserve for an amount not to exceed $12,350. 3) General Updates

4) Upcoming CRWD events and meetings a) Tuesday, July 16, 2019 Metro MAWD b) Wednesday, July 17, 2019 CAC Tour, 5:30 PM c) Wednesday, July 24, 2019 Board Meeting, 6:00 PM

Our Mission is to protect, manage and improve the water resources of Capitol Region Watershed District.


5) Staff issued Erosion and Sediment Control (ESC) Does not include staff issued ESC permits in advance of a full Board approved permit when grading work is scheduled to begin before stormwater details have been settled. 15-007, Ramsey County Demo: staff amended for erosion/sediment control changes, demo material to be hauled off site later this summer.

W:\04 Board of Managers\Correspondence\Administrator's Report 2019\Administrator's Report 5-29-19.docx

Our Mission is to protect, manage and improve the water resources of Capitol Region Watershed District.


Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.