ICON®Arctic
The Quality Connection
Instrumentation Cable
www.leoni-industrial-projects.com
2
Product range ■■ ■■ ■■ ■■ ■■ ■■ ■■
Telecommunication cables Data- and Bus cables (copper and fiber optic) Mining cables Cables for special applications Instrumentation- and control cables Thermocouple extension and compensating cables Power cables (low and medium voltage)
ICON®Arctic The well-known range of ICON® instrumentation cables includes cables dedicated to arctic conditions, i.e. extremely low temperatures. Cables are according to EN 50288-7 and other standards. The extended requirements are related to installation and operation conditions. In arctic areas cable installations shall be done at low temperatures without pre-heating of the cables. Temperatures down to -30 °C are common. Today most PVC compounds are not suitable for installation at temperatures below -5 °C in order to avoid cracks. In case installation was performed at lower temperatures cables had to be pre-heated.The cable temperature had to be continuously observed during installation. To fulfil such arctic conditions a new PVC sheathing compound was developed, called FRILON. This compound enables design and construction of instrumentation cables suitable for installation and operation at extremely low temperatures.It combines in an outstanding way cold resistance with excellent fire protection behaviour. Other properties, like cold impact, cold bending and cold elongation were improved regarding extremely low temperatures as well. LEONI Kerpen cold resistant cables are suitable for installation at temperatures down to -30°C without necessity of pre-heating of cables. In addition to excellent cold flexible behaviour during installation LEONI
www.leoni-industrial-projects.com
3
Table of contents Cables for extremely low temperatures, FRILON sheath 2
ICON Brands / Introduction
4
GOST certificates 6
Unarmoured types Instrumentation control cables , Multi-Core 500 V Collective Screen, RE-Y(St)Y-fl
10
Instrumentation cables, Single & Multi-Pair 300 V Collective Screen, RE-Y(St)Y-fl Individual & Collective Screen, RE-Y(St)Y-fl PiMF
12 17
Armoured types Instrumentation control cables, Multi-Core 500 V Collective Screen, RE-Y(St)YSWAY-fl Instrumentation cables, Single & Multi-Pair, 300 V Collective Screen, RE-Y(St)YSWAY-fl Individual & Collective Screen, RE-Y(St)YSWAY-fl PiMF
22 26 29
our cables are guaranteed in service at temperatures down to -60 °C with the function of the measurement and control system remaining undisturbed. FRILON fulfils the requirements of ST2 according to IEC 60502-1 as well as of TM52 according to EN 50290-2-22. Typical characteristics in extension to the standards mentioned above are: Temperature ranges Installation: - 30 °C to + 50 °C Operation - 60 °C to + 70 °C The characteristic profile of the cables is established through extensive testing in accordance with the standards listed below: Cold bending test IEC 60811-1-4 at - 50 °C Cold impact test IEC 60811-1-4 at- 55 °C (cables with round steel wire armour) - 45°C (unarmoured cables) Cold elongation test IEC 60811-1-4 at - 50 °C.
LEONI Kerpen GmbH can not be held responsible in any form whatsover for any information provided by this publication. Printing errors excepted. Subject to alterations. Issue 20100329 (replaces Issue 20080703)
LEONI
4
www.leoni-industrial-projects.com
ICON® Five new brands possess the optimized cable solution for your plant:
LEONI
ICON®Base
... ensures reliable performance in all usual conditions.
ICON®Chem
... ensures the safety and functionality of your plant in aggressive environments.
ICON®Arctic
... offers excellent properties for applications in extremely cold environments.
ICON®Safe
... offers protection for saving lives and safeguarding investments.
ICON®Bus
... meets or exceeds the increased requirements of state-of-the-art automation technology.
www.leoni-industrial-projects.com
5
LEONI Industrial Projects – your expert for a market that requires maximum reliability
LEONI is one of the leading suppliers of standardised and customer-specific special cables and pre-assembled cable systems worldwide. The Business Unit Industrial Projects allows us to give our customers access to the entire competence of a worldwide corporation, focused to meet the needs of industrial applications. We supply our products and solutions wherever everything depends on maximum reliability, quality and durability, such as in oil and gas extraction and processing as well as in the petrochemical and energy production industries. LEONI products are to be found in many other applications such as the pulp and paper, cement and pharmaceutical industries and in waste management, in which processes have to run in a controlled way via sensors and actuators. For us reliability doesn’t just mean keeping the right product available for you as a standard product or developing a project solution for you – it also means supplying it at precisely the agreed time.
Please visit our website www.leoni-industrial-projects.com
Safety, availability and reliability are vital in industrial plant engineering and energy provision. This is because these are fields in which unexpected breakdowns are very expensive and have critical effects on the environment. Companies are asking for solutions which are perfectly tailored to meet the application in question as well as the plant itself. 70 % of the cables leaving our company are developed, manufactured and assembled according to customer specifications. We produce quantities depending on the requirements of the projects and supply according to cable drumming schedules. We are also equipped to provide project quantities in a considerable two-digit million euro range. We take company-specific standards as well as all important industrial and environmental standards on the national and international level into account.
LEONI
6
GOST Certificates
LEONI
www.leoni-industrial-projects.com
www.leoni-industrial-projects.com
7
GOST Certificates
LEONI
8
LEONI
ICON Arctic grade
www.leoni-industrial-projects.com
www.leoni-industrial-projects.com
ICON Arctic grade
9
Unarmoured types
LEONI
10
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Control Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl Application For control purposes, e.g. controlling of valves or engines; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation in case of extreme low-temperature, on racks, trays, in conduits, in dry and wet locations; not for direct burial.
Construction Conductor
plain annealed copper, stranded, sizes: 0.5 mm², 0.75 mm², 1.0 mm², 1.3 mm², 1.5 mm², 2.5 mm²
Insulation
polyvinyl chloride PVC
Colour code
black, continuously numbered
Wrapping
at least 1 layer of plastic tape
Collective screen
24 µm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm²
Outer sheath
special polyvinyl chloride PVC (FRILON), black; blue for intrinsically safe systems
Cable marking
LEONI KERPEN ICON INSTRUMENTATION CONTROL CABLE COLD RESISTANT 500V RP EN 50288-7 CE length marking
Technical data
Abbreviations
Flame propagation:
Temperature range:
RE-
Instrumentation Cable
Test on single cable:
IEC 60332-1-2
-60 °C up to +70 °C
Y
insulation of PVC
Test on bunched cables:
IEC 60332-3-24 (Cat. C)
(during operation)
(St)
collective screen
-30 °C up to +50 °C
Y
outer sheath of special PVC
(during installation)
-fl
with reduced flame propagation
Ø
diameter
Low-temperature behaviour: Cold impact:
IEC 60811 (-45 °C)
Cold elongation:
IEC 60811 (-50 °C)
Cold bending:
IEC 60811 (-50 °C)
Sunlight resistance:
UL 1581 section 1200
Min. bending radius
Oil resistance:
ICEA S-73-532
7.5 x cable-Ø
Electrical data at 20 °C Character
Unit
Conductor size
nom.
mm²
0.5 36.0
Conductor resistance
max.
Ω/km
Insulation resistance
min.
MΩ x km
Mutual capacitance
max.
nF/km
Inductance
max.
mH/km
L/R (ratio)
max.
µH/Ω
Values 0.75 24.5
1.0 18.1
1.5
2.5
13.9
12.1
7.4
100 170
170
170
25
25
25
170
170
170
40
40
60
1
Test voltage
LEONI
1.3
core : core
U(rms)
V
2000
core : screen
U(rms)
V
2000
Operating voltage
U(rms)
V
500
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Control Cable
11
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl Geometrical data No. of cores
RT of insulation
RT of outer sheath
Overall diameter
Weight
Part No.
nom.
nom.
(mm)
(mm)
approx.
approx.
Outer sheath:
(mm)
(kg/km)
black
0.5 mm²/7 2
0.55
0.9
6.2
50
7774S001
3
0.55
0.9
6.5
65
7774S004
4
0.55
0.9
7.0
70
7774S007
5
0.55
0.9
7.6
80
7774S010
7
0.55
0.9
8.2
100
7774S013
8
0.55
1.0
9.1
120
7774S016
10
0.55
1.0
10.4
140
7774S019
12
0.55
1.0
10.7
160
7774S022
14
0.55
1.0
11.3
185
7774S025
16
0.55
1.0
11.8
200
7774S028
20
0.55
1.1
13.3
250
7774S034
24
0.55
1.1
14.7
290
7774S037
27
0.55
1.1
15.0
320
7774S040
30
0.55
1.2
15.7
355
7774S043
37
0.55
1.2
16.9
420
7774S046
40
0.55
1.2
17.6
450
7774S049
2
0.55
0.9
6.5
55
7774S052
3
0.55
0.9
6.9
75
7774S055
4
0.55
0.9
7.4
80
7774S058
5
0.55
0.9
8.1
105
7774S061
7
0.55
0.9
8.7
120
7774S064
8
0.55
1.0
9.7
145
7774S067
10
0.55
1.0
11.1
170
7774S070
12
0.55
1.0
11.5
200
7774S073
14
0.55
1.1
12.2
225
7774S076
16
0.55
1.1
12.9
255
7774S079
20
0.55
1.1
14.3
305
7774S085
24
0.55
1.2
16.0
365
7774S088
27
0.55
1.2
16.3
400
7774S091
30
0.55
1.2
16.9
440
7774S094
37
0.55
1.2
18.2
525
7774S097
40
0.55
1.3
19.1
570
7774S100
0.75 mm²/7
LEONI
12
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Control Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl Geometrical data No. of cores
RT of insulation
RT of outer sheath
Overall diameter
Weight
Part No.
nom.
nom.
approx.
approx.
Outer sheath:
(mm)
(mm)
(mm)
(kg/km)
black
1.0 mm²/7 2
0.55
0.9
6.9
65
7774S103
3
0.55
0.9
7.3
90
7774S106
4
0.55
0.9
7.9
95
7774S109
5
0.55
0.9
8.6
120
7774S112
7
0.55
1.0
9.5
150
7774S115
8
0.55
1.0
10.3
170
7774S118
10
0.55
1.0
11.9
210
7774S121
12
0.55
1.0
12.2
240
7774S124
14
0.55
1.1
13.0
270
7774S127
16
0.55
1.1
13.7
315
7774S130
20
0.55
1.1
15.2
375
7774S136
24
0.55
1.2
17.0
450
7774S139
27
0.55
1.2
17.4
495
7774S142
30
0.55
1.2
18.0
540
7774S145
37
0.55
1.3
19.6
660
7774S148
40
0.55
1.3
20.4
705
7774S151
0.60
0.9
7.4
75
7774S154
1.3 mm²/7 2
LEONI
3
0.60
0.9
7.9
105
7774S157
4
0.60
0.9
8.5
115
7774S160
5
0.60
1.0
9.5
145
7774S163
7
0.60
1.0
10.3
180
7774S166
8
0.60
1.0
11.2
200
7774S169
10
0.60
1.1
13.2
250
7774S172
12
0.60
1.1
13.6
290
7774S175
14
0.60
1.1
14.3
330
7774S178
16
0.60
1.1
15.0
380
7774S181
20
0.60
1.2
16.9
460
7774S187
24
0.60
1.2
18.7
550
7774S190
27
0.60
1.3
19.3
605
7774S193
30
0.60
1.3
20.0
665
7774S196
37
0.60
1.3
21.6
810
7774S199
40
0.60
1.4
22.7
865
7774S202
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Control Cable
13
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl Geometrical data No. of cores
RT of insulation
RT of outer sheath
Overall diameter
Weight
Part No.
nom.
nom.
approx.
approx.
Outer sheath:
(mm)
(mm)
(mm)
(kg/km)
black
1.5 mm²/7 2
0.60
0.9
7.7
82
7774S205
3
0.60
0.9
8.1
105
7774S208
4
0.60
0.9
8.8
130
7774S211
5
0.60
1.0
9.8
155
7774S214
7
0.60
1.0
10.7
200
7774S217
8
0.60
1.0
11.6
225
7774S220
10
0.60
1.1
13.7
285
7774S223
12
0.60
1.1
14.1
325
7774S226
14
0.60
1.1
14.8
375
7774S229
16
0.60
1.1
15.6
415
7774S232
20
0.60
1.2
17.6
515
7774S238
24
0.60
1.3
19.6
610
7774S241
27
0.60
1.3
20.1
680
7774S244
30
0.60
1.3
20.8
740
7774S247
37
0.60
1.4
22.6
905
7774S250
40
0.60
1.4
23.6
970
7774S253
2
0.70
0.9
8.9
115
7774S256
3
0.70
1.0
9.7
165
7774S259
4
0.70
1.0
10.5
180
7774S262
5
0.70
1.0
11.5
215
7774S265
7
0.70
1.1
12.7
290
7774S268
2.5 mm²/7
8
0.70
1.1
13.9
340
7774S271
10
0.70
1.2
16.3
420
7774S274
12
0.70
1.2
16.9
480
7774S277
14
0.70
1.2
17.7
550
7774S280
16
0.70
1.3
18.9
625
7774S283
20
0.70
1.3
21.1
765
7774S289
24
0.70
1.4
23.6
925
7774S292
27
0.70
1.4
24.1
1020
7774S295
30
0.70
1.5
25.2
1130
7774S298
37
0.70
1.5
27.2
1375
7774S301
40
0.70
1.6
28.5
1480
7774S304
RT = Radial Thickness
LEONI
14
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl Application For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation in case of extreme low-temperature; on racks, trays, in conduits, in dry and wet locations; not for direct burial.
Construction Conductor
plain annealed copper, stranded, sizes: 0.5 mm², 0.75 mm², 1.0 mm², 1.3 mm², 1.5 mm², 2.5 mm²
Insulation
polyvinyl chloride PVC
Colour code
black / white, continuously numbered on white core (1, 2..) for multipairs
Wrapping
at least 1 layer of plastic tape
Collective screen
24 µm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm²
Outer sheath
special polyvinyl chloride PVC (FRILON), black; blue for intrinsically safe systems
Cable marking
LEONI KERPEN ICON INSTRUMENTATION CABLE COLD RESISTANT 300V RP EN 50288-7 CE length marking
Technical data
Abbreviations
Flame propagation:
Temperature range:
RE-
Instrumentation Cable
Test on single cable:
IEC 60332-1-2
-60 °C up to +70 °C
Y
insulation of PVC
Test on bunched cables:
IEC 60332-3-24 (Cat. C)
(during operation)
(St)
collective screen
-30 °C up to +50 °C
Y
outer sheath of special PVC
(during installation)
-fl
with reduced flame propagation
Ø
diameter
Low-temperature behaviour: Cold impact:
IEC 60811 (-45 °C)
Cold elongation:
IEC 60811 (-50 °C)
Cold bending:
IEC 60811 (-50 °C)
Sunlight resistance:
UL 1581 section 1200
Min. bending radius
Oil resistance:
ICEA S-73-532
7.5 x cable-Ø
Electrical data at 20 °C Character
Unit
Values
Conductor size
nom.
mm²
0.5
Conductor resistance
max.
Ω/km
36.7
Insulation resistance
min.
MΩ x km
Mutual capacitance
max.
nF/km
single pair
0.75 25.0
1.0
1.3
1.5
2.5
18.5
14.2
12.3
7.6
100 190
190
190
200
200
up to 4 pairs
180
180
180
192
192
192
above 4 pairs
150
150
150
160
160
160
40
40
60
Inductance
max.
mH/km
L/R (ratio)
max.
µH/Ω
1 25
25
25
Test voltage
LEONI
200
core : core
U(rms)
V
1500
core : screen
U(rms)
V
1500
Operating voltage
U(rms)
V
300
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
15
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl Geometrical data No. of pairs
RT of insulation
RT of outer sheath
Overall diameter
Weight
Part No.
nom.
nom.
approx.
approx.
Outer sheath:
(mm)
(mm)
(mm)
(kg/km)
black
0.5 mm²/7 1
0.35
0.8
5.2
40
7774R001
2
0.35
0.9
7.6
70
7774R004
4
0.35
0.9
8.8
100
7774R007
5
0.35
1.0
9.8
125
7774R151
6
0.35
1.0
10.6
145
7774R010
8
0.35
1.0
11.3
170
7774R013
10
0.35
1.1
12.9
210
7774R016
12
0.35
1.1
13.5
245
7774R019
16
0.35
1.1
15.2
310
7774R022
20
0.35
1.2
16.9
380
7774R025
24
0.35
1.2
18.3
445
7774R028
0.38
0.8
5.6
50
7774R031
0.75 mm²/7 1 2
0.38
0.9
8.5
85
7774R034
4
0.38
1.0
10.0
130
7774R037
5
0.38
1.0
10.9
155
7774R154
6
0.38
1.0
11.8
180
7774R040
8
0.38
1.1
12.8
220
7774R043
10
0.38
1.1
14.5
270
7774R046
12
0.38
1.1
15.1
310
7774R049
16
0.38
1.2
17.3
405
7774R052
20
0.38
1.3
19.2
500
7774R055
24
0.38
1.3
20.8
585
7774R058
1.0 mm²/7 1
0.40
0.9
6.3
60
7774R061
2
0.40
0.9
9.2
100
7774R064
4
0.40
1.0
10.9
160
7774R067
5
0.40
1.0
11.9
190
7774R157
6
0.40
1.0
13.0
230
7774R070
8
0.40
1.1
14.0
280
7774R073
10
0.40
1.1
15.9
340
7774R076
12
0.40
1.2
16.8
405
7774R079
16
0.40
1.2
19.0
520
7774R082
20
0.40
1.3
21.1
640
7774R085
24
0.40
1.4
23.1
765
7774R088
LEONI
16
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl Geometrical data No. of pairs
RT of insulation
RT of outer sheath
Overall diameter
Weight
Part No.
nom.
nom.
approx.
approx.
Outer sheath:
(mm)
(mm)
(mm)
(kg/km)
black
1.3 mm²/7 1
0.45
0.9
6.8
70
7774R091
2
0.45
1.0
10.4
130
7774R094
4
0.45
1.0
12.0
200
7774R097
5
0.45
1.1
13.4
250
7774R160
6
0.45
1.1
14.6
295
7774R100
8
0.45
1.2
15.7
360
7774R103
10
0.45
1.2
17.9
445
7774R106
12
0.45
1.3
18.9
525
7774R109
16
0.45
1.3
21.4
675
7774R112
20
0.45
1.4
23.8
835
7774R115
24
0.45
1.5
25.9
995
7774R118
0.45
0.9
7.1
75
7774R121
1.5 mm²/7 1 2
0.45
1.0
10.8
135
7774R124
4
0.45
1.1
12.7
215
7774R127
5
0.45
1.1
14.0
265
7774R163
6
0.45
1.1
15.2
315
7774R130
8
0.45
1.2
16.4
390
7774R133
10
0.45
1.3
18.8
485
7774R136
12
0.45
1.3
19.7
565
7774R139
16
0.45
1.4
22.5
740
7774R142
20
0.45
1.5
25.0
915
7774R145
24
0.45
1.5
27.1
1075
7774R148
2.5 mm²/7 1
0.55
0.9
8.3
110
7774R955
2
0.55
1.1
13.1
215
7774R956
4
0.55
1.1
15.3
325
7774R957
5
0.55
1.2
17.0
415
7774R958
6
0.55
1.2
18.6
485
7774R959
8
0.55
1.3
20.0
610
7774R960
10
0.55
1.4
23.0
780
7774R961
12
0.55
1.5
24.3
900
7774R962
16
0.55
1.5
27.6
1175
7774R963
20
0.55
1.7
30.8
1455
7774R964
24
0.55
1.8
33.6
1755
7774R965
RT = Radial Thickness LEONI
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
17
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Individual & Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl PiMF Application For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation in case of extreme low-temperature; on racks, trays, in conduits, in dry and wet locations; not for direct burial.
Construction Conductor
plain annealed copper, stranded, sizes: 0.5 mm², 0.75 mm², 1.0 mm², 1.3 mm², 1.5 mm², 2.5 mm²
Insulation
polyvinyl chloride PVC
Colour code
black / white, continuously numbered on white core (1, 2..) for multipairs
Individual shield
24 µm aluminium / PETP tape over solid tinned copper drain wire, 0.6 mm Ø, plastic tape under and above screen
Wrapping
at least 1 layer of plastic tape
Collective screen
24 µm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm²
Outer sheath
special polyvinyl chloride PVC (FRILON), black; blue for intrinsically safe systems
Cable marking
LEONI KERPEN ICON INSTRUMENTATION CABLE COLD RESISTANT 300V RP EN 50288-7 CE length marking
Technical data
Abbreviations
Flame propagation:
Temperature range:
RE-
Instrumentation cable
Test on single cable:
IEC 60332-1-2
-60 °C up to +70 °C
Y
insulation of PVC
Test on bunched cables:
IEC 60332-3-24 (Cat. C)
(during operation)
(St)
collective screen
-30 °C up to +50 °C
Y
outer sheath of special PVC
(during installation)
-fl
with reduced flame propagation
Low-temperature behaviour: Cold impact:
IEC 60811 (-45 °C)
Cold elongation:
IEC 60811 (-50 °C)
PiMF
pair in metal foil
Cold bending:
IEC 60811 (-50 °C)
Ø
diameter
Sunlight resistance:
UL 1581 section 1200
Min. bending radius
Oil resistance:
ICEA S-73-532
7.5 x cable-Ø
Electrical data at 20 °C Character
Unit
Conductor size
nom.
mm²
0.5
Conductor resistance
max.
Ω/km
36.7
Insulation resistance
min.
MΩ x km
Mutual capacitance
max.
nF/km
Inductance
max.
mH/km
L/R (ratio)
max.
µH/Ω
Values 0.75 25.0
1.0
1.3
1.5
2.5
18.5
14.2
12.3
7.6
100 190
190
190
200
200
200
40
40
60
1 25
25
25
Test voltage core : core
U(rms)
V
1500
core : screen
U(rms)
V
1500
Operating voltage
U(rms)
V
300
LEONI
18
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Individual & Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl PiMF Geometrical data No. of pairs
RT of insulation
RT of outer sheath
Overall diameter
Weight
Part No.
nom.
nom.
approx.
approx.
Outer sheath:
(mm)
(mm)
(mm)
(kg/km)
black
0.5 mm²/7 2
0.35
0.9
8.7
85
7774R166
4
0.35
1.0
10.2
130
7774R169
5
0.35
1.0
11.2
155
7774R172
6
0.35
1.0
12.2
180
7774R175
8
0.35
1.1
13.1
225
7774R178
10
0.35
1.2
15.1
280
7774R181
12
0.35
1.2
15.8
315
7774R184
16
0.35
1.2
17.8
400
7774R187
20
0.35
1.3
19.8
490
7779R190
24
0.35
1.4
21.6
590
7774R193
0.75 mm²/7 2
0.38
1.0
9.7
105
7774R196
4
0.38
1.0
11.2
150
7774R199
5
0.38
1.1
12.5
190
7774R202
6
0.38
1.1
13.6
225
7774R205
8
0.38
1.1
14.5
270
7774R208
10
0.38
1.2
16.6
340
7774R211
12
0.38
1.2
17.4
385
7774R214
16
0.38
1.3
19.8
505
7774R217
20
0.38
1.4
22.1
620
7774R220
24
0.38
1.5
24.1
740
7774R223
4
0.40
1.0
12.1
185
7774R229
5
0.40
1.1
13.5
230
7774R232
6
0.40
1.1
14.7
270
7774R235
8
0.40
1.2
15.9
340
7774R238
1.0 mm²/7
LEONI
10
0.40
1.2
18.0
415
7774R241
12
0.40
1.3
19.1
485
7774R244
16
0.40
1.3
21.6
620
7774R247
20
0.40
1.4
24.0
770
7774R250
24
0.40
1.5
26.2
915
7774R253
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
19
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Individual & Collective Screen, Special PVC Sheath (FRILON) RE-Y(St)Y-fl PiMF Geometrical data No. of pairs
RT of insulation
Overall diameter
Weight
Part No.
nom.
RT of outer sheath nom.
approx.
approx.
Outer sheath:
(mm)
(mm)
(mm)
(kg/km)
black
2
0.45
1.0
11.4
145
7774R256
4
0.45
1.1
13.5
230
7774R259
5
0.45
1.1
14.8
280
7774R262
6
0.45
1.2
16.3
340
7774R265
1.3 mm²/7
8
0.45
1.3
17.6
425
7774R268
10
0.45
1.3
20.0
525
7774R271
12
0.45
1.4
21.2
610
7774R274
16
0.45
1.5
24.1
800
7774R277
20
0.45
1.6
26.8
980
7774R280
24
0.45
1.7
29.2
1175
7774R283
2
0.45
1.0
11.8
155
7774R286
4
0.45
1.1
14.0
245
7774R289
5
0.45
1.2
15.5
310
7774R292
6
0.45
1.2
16.9
360
7774R295
1.5 mm²/7
8
0.45
1.3
18.3
455
7774R298
10
0.45
1.4
21.0
570
7774R301
12
0.45
1.4
22.0
650
7774R304
16
0.45
1.5
25.1
860
7774R307
20
0.45
1.6
27.9
1050
7774R310
24
0.45
1.7
30.4
1260
7774R313
2.5 mm²/7 2
0.55
1.1
14.1
235
7774R966
4
0.55
1.2
16.7
370
7774R967
5
0.55
1.3
18.6
465
7774R968
6
0.55
1.3
20.3
545
7774R969
8
0.55
1.4
21.9
705
7774R970
10
0.55
1.5
25.1
875
7774R971
12
0.55
1.6
26.6
1010
7774R972
16
0.55
1.7
30.3
1335
7774R973
20
0.55
1.8
33.7
1630
7774R974
24
0.55
1.9
36.7
1960
7774R975
RT = Radial Thickness
LEONI
20
LEONI
ICON Arctic grade
www.leoni-industrial-projects.com
www.leoni-industrial-projects.com
ICON Arctic grade
21
Armoured types
LEONI
22
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Control Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl Application For control purposes, e.g. controlling of valves or engines; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation in case of extreme low-temperature, on racks, trays, in conduits, in dry and wet locations; for direct burial.
Construction Conductor
plain annealed copper, stranded, sizes: 0.5 mm², 0.75 mm², 1.0 mm², 1.3 mm², 1.5 mm², 2.5 mm²
Insulation
polyvinyl chloride PVC
Colour code
black, continuously numbered
Wrapping
at least 1 layer of plastic tape
Collective screen
24 µm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm²
Inner sheath
special polyvinyl chloride PVC (FRILON), black
Armour
galvanized round steel wires
Outer sheath
special polyvinyl chloride PVC (FRILON), black; blue for intrinsically safe systems
Cable marking
LEONI KERPEN ICON INSTRUMENTATION CONTROL CABLE COLD RESISTANT 500V RP EN 50288-7 CE length marking
Technical data
Abbreviations
Flame propagation:
IEC 60332-1-2
Temperature range:
RE-
Instrumentation cable
Test on single cable:
IEC 60332-3-24 (Cat. C)
-60 °C up to +70 °C
Y
insulation of PVC
Test on bunched cables:
(during operation)
(St)
collective screen
Low-temperature behaviour:
-30 °C up to +50 °C
Y
inner sheath of special PVC
(during installation)
SWA
steel wire armour
Y
outer sheath of special PVC
-fl
with reduced flame propagation
Ø
diameter
Cold impact:
IEC 60811 (-55 °C)
Cold elongation:
IEC 60811 (-50 °C)
Cold bending:
IEC 60811 (-50 °C)
Sunlight resistance:
UL 1581 section 1200
Min. bending radius
Oil resistance:
ICEA S-73-532
10 x cable-Ø
Electrical data at 20 °C Character
Unit
Conductor size
nom.
mm²
0.5
Conductor resistance
max.
Ω/km
36.0
Insulation resistance
min.
MΩ x km
Mutual capacitance
max.
nF/km
Inductance
max.
mH/km
L/R (ratio)
max.
µH/Ω
Values 0.75 24.5
1.0 18.1
1.5
2.5
13.9
12.1
7.4
100 170
170
170
170
170
170
40
40
60
1 25
25
25
Test voltage
LEONI
1.3
core : core
U(rms)
V
2000
core : screen
U(rms)
V
2000
Operating voltage
U(rms)
V
500
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Control Cable
23
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl Geometrical data No. of cores
RT of
RT of inner
Ø over inner
Ø of armour
RT of outer
Overall
Weight
Part No.
insulation nom. (mm)
sheath nom. (mm)
sheath approx. (mm)
wire nom. (mm)
sheath nom. (mm)
diameter approx. (mm)
approx. (kg/km)
Outer sheath: black
0.9
1.3
215
7776S001
0.5 mm²/7 2
0.55
0.9
6.2
10.6
3
0.55
0.9
6.5
0.9
1.3
10.9
230
7776S004
4
0.55
0.9
7.0
0.9
1.3
11.4
250
7776S007
5
0.55
0.9
7.6
0.9
1.3
12.0
280
7776S010
7
0.55
0.9
8.2
0.9
1.4
12.8
305
7776S013
8
0.55
1.0
9.1
0.9
1.4
13.7
350
7776S016
10
0.55
1.0
10.4
0.9
1.4
15.0
400
7776S019
12
0.55
1.0
10.7
0.9
1.4
15.3
445
7776S022
14
0.55
1.0
11.3
0.9
1.4
15.9
475
7776S025
16
0.55
1.0
11.8
0.9
1.4
16.4
505
7776S028
20
0.55
1.1
13.3
0.9
1.5
18.1
580
7776S034
24
0.55
1.1
14.7
0.9
1.5
19.5
670
7776S037
27
0.55
1.1
15.0
0.9
1.5
19.8
815
7776S040
30
0.55
1.2
15.7
0.9
1.5
20.5
860
7776S043
37
0.55
1.2
16.9
0.9
1.6
21.9
980
7776S046
40
0.55
1.2
17.6
1.25
1.6
23.3
1035
7776S049
0.55
0.9
6.5
0.9
1.3
10.9
225
7776S052
0.75 mm²/7 2 3
0.55
0.9
6.9
0.9
1.3
11.3
250
7776S055
4
0.55
0.9
7.4
0.9
1.3
11.8
275
7776S058
5
0.55
0.9
8.1
0.9
1.4
12.7
320
7776S061
7
0.55
0.9
8.7
0.9
1.4
13.3
340
7776S064
8
0.55
1.0
9.7
0.9
1.4
14.3
390
7776S067
10
0.55
1.0
11.1
0.9
1.4
15.7
460
7776S070
12
0.55
1.0
11.5
0.9
1.4
16.1
495
7776S073
14
0.55
1.1
12.2
0.9
1.5
17.0
530
7776S076
16
0.55
1.1
12.9
0.9
1.5
17.7
570
7776S079
20
0.55
1.1
14.3
0.9
1.5
19.1
675
7776S085
24
0.55
1.2
16.0
0.9
1.5
20.8
880
7776S088
27
0.55
1.2
16.3
0.9
1.6
21.3
940
7776S091
30
0.55
1.2
16.9
0.9
1.6
21.9
1000
7776S094
37
0.55
1.2
18.2
1.25
1.6
23.9
1110
7776S097
40
0.55
1.3
19.1
1.25
1.6
24.8
1200
7776S100
LEONI
ICON Arctic grade
24
www.leoni-industrial-projects.com
Instrumentation Control Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl Geometrical data No. of cores
RT of
RT of inner
Ø over inner
Ø of armour
RT of outer
Overall
Weight
Part No.
insulation nom. (mm)
sheath nom. (mm)
sheath approx. (mm)
wire nom. (mm)
sheath nom. (mm)
diameter approx. (mm)
approx. (kg/km)
Outer sheath: black
1.0 mm²/7 2
0.55
0.9
6.9
0.9
1.3
11.3
240
7776S103
3
0.55
0.9
7.3
0.9
1.3
11.7
265
7776S106
4
0.55
0.9
7.9
0.9
1.4
12.5
295
7776S109
5
0.55
0.9
8.6
0.9
1.4
13.2
337
7776S112
7
0.55
1.0
9.5
0.9
1.4
14.1
385
7776S115
8
0.55
1.0
10.3
0.9
1.4
14.9
425
7776S118
10
0.55
1.0
11.9
0.9
1.4
16.5
515
7776S121
12
0.55
1.0
12.2
0.9
1.5
17.0
550
7776S124
14
0.55
1.1
13.0
0.9
1.5
17.8
595
7776S127
16
0.55
1.1
13.7
0.9
1.5
18.5
655
7776S130
20
0.55
1.1
15.2
0.9
1.5
20.0
870
7776S136
24
0.55
1.2
17.0
0.9
1.6
22.0
1010
7776S139
27
0.55
1.2
17.4
1.25
1.6
23.1
1070
7776S142
30
0.55
1.2
18.0
1.25
1.6
23.7
1130
7776S145
37
0.55
1.3
19.6
1.25
1.6
25.3
1295
7776S148
40
0.55
1.3
20.4
1.25
1.7
26.3
1375
7776S151
1.3 mm²/7
LEONI
2
0.60
0.9
7.4
0.9
1.3
11.8
270
7776S154
3
0.60
0.9
7.9
0.9
1.3
12.3
305
7776S157
4
0.60
0.9
8.5
0.9
1.4
13.1
335
7776S160
5
0.60
1.0
9.5
0.9
1.4
14.1
380
7776S163
7
0.60
1.0
10.3
0.9
1.4
14.9
430
7776S166
8
0.60
1.0
11.2
0.9
1.4
15.8
480
7776S169
10
0.60
1.1
13.2
0.9
1.5
18.0
575
7776S172
12
0.60
1.1
13.6
0.9
1.5
18.4
635
7776S175
14
0.60
1.1
14.3
0.9
1.5
19.1
700
7776S178
16
0.60
1.1
15.0
0.9
1.5
19.8
870
7776S181
20
0.60
1.2
16.9
0.9
1.6
21.9
1010
7776S187
24
0.60
1.2
18.7
1.25
1.6
24.4
1170
7776S190
27
0.60
1.3
19.3
1.25
1.6
25.0
1230
7776S193
30
0.60
1.3
20.0
1.25
1.6
25.7
1310
7776S196
37
0.60
1.3
21.6
1.25
1.7
27.5
1520
7776S199
40
0.60
1.4
22.7
1.25
1.7
28.6
1600
7776S202
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Control Cable
25
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 500 V
Multi-Core, PVC Insulation, Collective Screen, Armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl Geometrical data RT of
RT of inner
Ø over inner
Ø of armour
RT of outer
Overall
Weight
Part No.
insulation nom. (mm)
sheath nom. (mm)
sheath approx. (mm)
wire nom. (mm)
sheath nom. (mm)
diameter approx. (mm)
approx. (kg/km)
Outer sheath: black
No. of cores
1.5 mm²/7 2
0.60
0.9
7.7
0.9
1.3
12.1
285
7776S205
3
0.60
0.9
8.1
0.9
1.4
12.7
330
7776S208
4
0.60
0.9
8.8
0.9
1.4
13.4
345
7776S211
5
0.60
1.0
9.8
0.9
1.4
14.4
400
7776S214
7
0.60
1.0
10.7
0.9
1.4
15.3
460
7776S217
8
0.60
1.0
11.6
0.9
1.4
16.2
510
7776S220
10
0.60
1.1
13.7
0.9
1.5
18.5
630
7776S223
12
0.60
1.1
14.1
0.9
1.5
18.9
685
7776S226
14
0.60
1.1
14.8
0.9
1.5
19.6
745
7776S229
16
0.60
1.1
15.6
0.9
1.5
20.4
925
7776S232
20
0.60
1.2
17.6
1.25
1.6
23.3
1090
7776S238
24
0.60
1.3
19.6
1.25
1.6
25.3
1255
7776S241
27
0.60
1.3
20.1
1.25
1.6
25.8
1330
7776S244
30
0.60
1.3
20.8
1.25
1.7
26.7
1430
7776S247
37
0.60
1.4
22.6
1.25
1.7
28.5
1645
7776S250
40
0.60
1.4
23.6
1.25
1.7
29.5
1750
7776S253
2.5 mm²/7 2
0.70
0.9
8.9
0.9
1.4
13.5
370
7776S256
3
0.70
1.0
9.7
0.9
1.4
14.3
440
7776S259
4
0.70
1.0
10.5
0.9
1.4
15.1
440
7776S262
5
0.70
1.0
11.5
0.9
1.4
16.1
540
7776S265
7
0.70
1.1
12.7
0.9
1.5
17.5
605
7776S268
8
0.70
1.1
13.9
0.9
1.5
18.7
700
7776S271
10
0.70
1.2
16.3
0.9
1.6
21.3
950
7776S274
12
0.70
1.2
16.9
0.9
1.6
21.9
1040
7776S277
14
0.70
1.2
17.7
1.25
1.6
23.4
1130
7776S280
16
0.70
1.3
18.9
1.25
1.6
24.6
1255
7776S283
20
0.70
1.3
21.1
1.25
1.7
27.0
1470
7776S289
24
0.70
1.4
23.6
1.25
1.7
29.5
1690
7776S292
27
0.70
1.4
24.1
1.25
1.8
30.2
1830
7776S295
30
0.70
1.5
25.2
1.25
1.8
31.3
2140
7776S298
37
0.70
1.5
27.2
1.25
1.8
33.3
2470
7776S301
40
0.70
1.6
28.5
1.25
1.9
34.8
2610
7776S304
RT = Radial Thickness
LEONI
26
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Collective Screen, Armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl Application For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation in case of extreme low-temperature, on racks, trays, in conduits, in dry and wet locations; for direct burial.
Construction Conductor
plain annealed copper, stranded, sizes: 0.5 mm², 0.75 mm², 1.0 mm², 1.3 mm², 1.5 mm², 2.5 mm²
Insulation
polyvinyl chloride PVC
Colour code
black / white, continuously numbered on white core (1, 2..) for multipairs
Wrapping
at least 1 layer of plastic tape
Collective screen
24 µm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm²
inner sheath
special polyvinyl chloride PVC (FRILON), black
Armour
galvanized round steel wires
Outer sheath
special polyvinyl chloride PVC (FRILON), black; blue for intrinsically safe systems
Cable marking
LEONI KERPEN ICON INSTRUMENTATION CABLE COLD RESISTANT 300V RP EN 50288-7 CE length marking
Technical data
Abbreviations
Flame propagation:
Temperature range:
RE-
Instrumentation Cable
Test on single cable:
IEC 60332-1-2
-60 °C up to +70 °C
Y
insulation of PVC
Test on bunched cables:
IEC 60332-3-24 (Cat. C)
(during operation)
(St)
collective screen
-30 °C up to +50 °C
Y
inner sheath of special PVC
(during installation)
SWA
steel wire armour
Y
outer sheath of special PVC
-fl
with reduced flame propagation
Ø
diameter
Low-temperature behaviour: Cold impact:
IEC 60811 (-55 °C)
Cold elongation:
IEC 60811 (-50 °C)
Cold bending:
IEC 60811 (-50 °C)
Sunlight resistance:
UL 1581 section 1200
Min. bending radius
Oil resistance:
ICEA S-73-532
10 x cable-Ø
Electrical data at 20 °C Character
Unit
Conductor size
nom.
mm²
0.5
Values
Conductor resistance
max.
Ω/km
36.7
Insulation resistance
min.
MΩ x km
Mutual capacitance
max.
nF/km
0.75 25.0
1.0
1.3
1.5
2.5
18.5
14.2
12.3
7.6
100
single pair
190
190
190
200
200
200
up to 4 pairs
180
180
180
192
192
192
150
150
150
160
160
160
40
40
60
above 4 pairs Inductance
max.
mH/km
L/R (ratio)
max.
µH/Ω
1 25
25
25
Test voltage
LEONI
core : core
U(rms)
V
1500
core : screen
U(rms)
V
1500
Operating voltage
U(rms)
V
300
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
27
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Collective Screen, Armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl Geometrical data No. of pairs
RT of
RT of inner
Ø over inner
Ø of armour
RT of outer
Overall
insulation
sheath
sheath
wire
sheath
diameter
nom. (mm)
nom. (mm)
approx. (mm)
nom. (mm)
nom. (mm)
approx. (mm)
0.9
1.3
Weight
Part No.
approx. (kg/km)
Outer sheath: black
180
7776R001
0.5 mm²/7 1
0.35
0.8
5.2
9.6
2
0.35
0.9
7.6
0.9
1.3
12.0
260
7776R004
4
0.35
0.9
8.8
0.9
1.4
13.4
320
7776R007
5
0.35
1.0
9.8
0.9
1.4
14.4
370
7776R151
6
0.35
1.0
10.6
0.9
1.4
15.2
410
7776R010
8
0.35
1.0
11.3
0.9
1.4
15.9
450
7776R013
10
0.35
1.1
12.9
0.9
1.5
17.7
530
7776R016
12
0.35
1.1
13.5
0.9
1.5
18.3
575
7776R019
16
0.35
1.1
15.2
0.9
1.5
20.0
680
7776R022
20
0.35
1.2
16.9
0.9
1.6
21.9
800
7776R025
24
0.35
1.2
18.3
1.25
1.6
24.0
1020
7776R028
0.75 mm²/7 1
0.38
0.8
5.6
0.9
1.3
10.0
195
7776R031
2
0.38
0.9
8.5
0.9
1.4
13.1
300
7776R034
4
0.38
1.0
10.0
0.9
1.4
14.6
375
7776R037
5
0.38
1.0
10.9
0.9
1.4
15.5
425
7776R154
6
0.38
1.0
11.8
0.9
1.4
16.4
470
7776R040
8
0.38
1.1
12.8
0.9
1.5
17.6
540
7776R043
10
0.38
1.1
14.5
0.9
1.5
19.3
625
7776R046
12
0.38
1.1
15.1
0.9
1.5
19.9
680
7776R049
16
0.38
1.2
17.3
0.9
1.6
22.3
835
7776R052
20
0.38
1.3
19.2
1.25
1.6
24.9
1100
7776R055
24
0.38
1.3
20.8
1.25
1.7
26.7
1245
7776R058
1
0.40
0.9
6.3
0.9
1.3
10.7
220
7776R061
2
0.40
0.9
9.2
0.9
1.4
13.8
335
7776R064
4
0.40
1.0
10.9
0.9
1.4
15.5
430
7776R067
5
0.40
1.0
11.9
0.9
1.4
16.5
480
7776R157
6
0.40
1.0
13.0
0.9
1.4
17.6
545
7776R070
1.0 mm²/7
8
0.40
1.1
14.0
0.9
1.5
18.8
625
7776R073
10
0.40
1.1
15.9
0.9
1.5
20.7
725
7776R076
12
0.40
1.2
16.8
0.9
1.5
21.6
810
7776R079
16
0.40
1.2
19.0
1.25
1.6
24.7
1120
7776R082
20
0.40
1.3
21.1
1.25
1.7
27.0
1300
7776R085
24
0.40
1.4
23.1
1.25
1.7
29.0
1490
7776R088
LEONI
ICON Arctic grade
28
www.leoni-industrial-projects.com
Instrumentation Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Collective Screen, Armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl Geometrical data No. of pairs
RT of
RT of inner
Ø over inner
Ø of armour
RT of outer
Overall
insulation
sheath
sheath
wire
sheath
diameter
nom. (mm)
nom. (mm)
approx. (mm)
nom. (mm)
nom. (mm)
approx. (mm)
Weight
Part No.
approx. (kg/km)
Outer sheath: black
1.3 mm²/7 1
0.45
0.9
6.8
0.9
1.3
11.2
245
7776R091
2
0.45
1.0
10.4
0.9
1.4
15.0
390
7776R094
4
0.45
1.0
12.0
0.9
1.4
16.6
490
7776R097
5
0.45
1.1
13.4
0.9
1.5
18.2
580
7776R160
6
0.45
1.1
14.6
0.9
1.5
19.4
650
7776R100
8
0.45
1.2
15.7
0.9
1.5
20.5
740
7776R103
10
0.45
1.2
17.9
1.25
1.6
23.6
1010
7776R106
12
0.45
1.3
18.9
1.25
1.6
24.6
1120
7776R109
16
0.45
1.3
21.4
1.25
1.7
27.3
1360
7776R112
20
0.45
1.4
23.8
1.25
1.8
29.9
1600
7776R115
24
0.45
1.5
25.9
1.25
1.8
32.0
1820
7776R118
1.5 mm²/7 1
0.45
0.9
7.1
0.9
1.3
11.5
255
7776R121
2
0.45
1.0
10.8
0.9
1.4
15.4
400
7776R124
4
0.45
1.1
12.7
0.9
1.5
17.5
535
7776R127
5
0.45
1.1
14.0
0.9
1.5
18.8
610
7776R163
6
0.45
1.1
15.2
0.9
1.5
20.0
685
7776R130
8
0.45
1.2
16.4
0.9
1.6
21.4
800
7776R133
10
0.45
1.3
18.8
1.25
1.6
24.5
1070
7776R136
12
0.45
1.3
19.7
1.25
1.7
25.6
1200
7776R139
16
0.45
1.4
22.5
1.25
1.7
28.4
1450
7776R142
20
0.45
1.5
25.0
1.25
1.8
31.1
1710
7776R145
24
0.45
1.5
27.1
1.25
1.8
33.2
1930
7776R148
1
0.55
0.9
8.3
0.9
1.4
12.9
320
7776R955
2
0.55
1.1
13.1
0.9
1.5
17.9
540
7776R956
2.5 mm²/7
4
0.55
1.1
15.3
0.9
1.5
20.1
700
7776R957
5
0.55
1.2
17.0
0.9
1.6
22.0
830
7776R958
6
0.55
1.2
18.6
1.25
1.6
24.3
1075
7776R959
8
0.55
1.3
20.0
1.25
1.7
25.9
1250
7776R960
10
0.55
1.4
23.0
1.25
1.8
29.1
1520
7776R961
12
0.55
1.5
24.3
1.25
1.8
30.4
1670
7776R962
16
0.55
1.5
27.6
1.25
1.8
33.7
2040
7776R963
20
0.55
1.7
30.8
1.6
2.0
38.0
2660
7776R964
24
0.55
1.8
33.6
1.6
2.0
40.8
3060
7776R965
RT = Radial Thickness
LEONI
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
29
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Individual & Collective Screen, armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl PiMF Application For transmission of analogue and digital signals in instrument and control systems; allowed for use in zone 1 and zone 2 group II classified areas (IEC 60079-14); not allowed for direct connection to low impedance source, e.g. the public mains electricity supply. Recommended for indoor and outdoor installation in case of extreme low-temperature, on racks, trays, in conduits, in dry and wet locations; for direct burial.
Construction Conductor
plain annealed copper, stranded, sizes: 0.5 mm², 0.75 mm², 1.0 mm², 1.3 mm², 1.5 mm², 2.5 mm²
Insulation
polyvinyl chloride PVC
Colour code
black / white, continuously numbered on white core (1, 2..) for multipairs
Individual shield
24 µm aluminium / PETP tape over solid tinned copper drain wire, 0.6 mm Ø, plastic tape under and above screen
Wrapping
at least 1 layer of plastic tape
Collective screen
24 µm aluminium / PETP tape over 7-stranded tinned copper drain wire, 0.5 mm²
Inner sheath
special polyvinyl chloride PVC (FRILON), black
Armour
galvanized round steel wires
Outer sheath
special polyvinyl chloride PVC (FRILON), black; blue for intrinsically safe systems
Cable marking
LEONI KERPEN ICON INSTRUMENTATION CABLE COLD RESISTANT 300V RP EN 50288-7 CE length marking
Technical data
Abbreviations
Flame propagation:
Temperature range:
RE-
Instrumentation cable
Test on single cable:
IEC 60332-1-2
-60 °C up to +70 °C
Y
insulation of PVC
Test on bunched cables:
IEC 60332-3-24 (Cat. C)
(during operation)
(St)
Collective screen
-30 °C up to +50 °C
Y
Inner sheath of PVC
(during installation)
SWA
Steel wire armour
Y
outer sheath of special PVC
Low-temperature behaviour: Cold impact:
IEC 60811 (-55 °C)
Cold elongation:
IEC 60811 (-50 °C)
Cold bending:
IEC 60811 (-50 °C)
Min. bending radius
-fl
with reduced flame propagation
Sunlight resistance:
UL 1581 section 1200
10 x cable-Ø
PiMF
pair in metal foil
Oil resistance:
ICEA S-73-532
Ø
diameter
Electrical data at 20 °C Character
Unit
Conductor size
nom.
mm²
0.5
Values
Conductor resistance
max.
Ω/km
36.7
Insulation resistance
min.
MΩ x km
Mutual capacitance
max.
nF/km
Inductance
max.
mH/km
L/R (ratio)
max.
µH/Ω
0.75 25.0
1.0
1.3
1.5
2.5
18.5
14.2
12.3
7.6
100 190
190
190
25
25
25
200
200
200
40
40
60
1
Test voltage core : core
U(rms)
V
1500
core : screen
U(rms)
V
1500
Operating voltage
U(rms)
V
300
LEONI
ICON Arctic grade
30
www.leoni-industrial-projects.com
Instrumentation Cable
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Individual & Collective Screen, armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl PiMF Geometrical data No. of pairs
RT of
RT of inner
Ø over inner
Ø of armour
RT of outer
Overall
insulation
sheath
sheath
wire
sheath
diameter
nom. (mm)
nom. (mm)
approx. (mm)
nom. (mm)
nom. (mm)
approx. (mm)
0.9
1.4
Weight
Part No.
approx. (kg/km)
Outer sheath: black
305
7776R166
0.5 mm²/7 2
0.35
0.9
8.7
13.3
4
0.35
1.0
10.2
0.9
1.4
14.8
380
7776R169
5
0.35
1.0
11.2
0.9
1.4
15.8
430
7776R172
6
0.35
1.0
12.2
0.9
1.5
17.0
485
7776R175
8
0.35
1.1
13.1
0.9
1.5
17.9
550
7776R178
10
0.35
1.2
15.1
0.9
1.5
19.9
650
7776R181
12
0.35
1.2
15.8
0.9
1.5
20.6
700
7776R184
16
0.35
1.2
17.8
1.25
1.6
23.5
965
7776R187
20
0.35
1.3
19.8
1.25
1.7
25.7
1125
7776R190
24
0.35
1.4
21.6
1.25
1.7
27.5
1280
7776R193
0.38
1.0
9.7
0.9
1.4
14.3
345
7776R196
0.75 mm²/7 2 4
0.38
1.0
11.2
0.9
1.4
15.8
430
7776R199
5
0.38
1.1
12.5
0.9
1.5
17.3
505
7776R202
6
0.38
1.1
13.6
0.9
1.5
18.4
565
7776R205
8
0.38
1.1
14.5
0.9
1.5
19.3
625
7776R208
10
0.38
1.2
16.6
1.25
1.6
22.3
870
7776R211
12
0.38
1.2
17.4
1.25
1.6
23.1
935
7776R214
16
0.38
1.3
19.8
1.25
1.7
25.7
1140
7776R217
20
0.38
1.4
22.1
1.25
1.7
28.0
1315
7776R220
24
0.38
1.5
24.1
1.25
1.8
30.2
1510
7776R223
0.40
1.0
10.4
0.9
1.4
15.0
380
7776R226
1.0 mm²/7 2
LEONI
4
0.40
1.0
12.1
0.9
1.4
16.7
480
7776R229
5
0.40
1.1
13.5
0.9
1.5
18.3
565
7776R232
6
0.40
1.1
14.7
0.9
1.5
19.5
630
7776R235
8
0.40
1.2
15.9
0.9
1.5
20.7
725
7776R238
10
0.40
1.2
18.0
1.25
1.6
23.7
980
7776R241
12
0.40
1.3
19.1
1.25
1.6
24.8
1100
7776R244
16
0.40
1.3
21.6
1.25
1.7
27.5
1305
7776R247
20
0.40
1.4
24.0
1.25
1.7
29.9
1525
7776R250
24
0.40
1.5
26.2
1.25
1.8
32.3
1750
7776R253
ICON Arctic grade
www.leoni-industrial-projects.com
Instrumentation Cable
31
EN 50288-7
GOST-R approved
Flame Retardant, Cold Resistant
70 °C / 300 V
Single & Multi-Pair, PVC Insulation, Individual & Collective Screen, armour, Special PVC Sheath (FRILON) RE-Y(St)YSWAY-fl PiMF Geometrical data No. of pairs
RT of
RT of inner
insulation
sheath
nom. (mm)
nom. (mm)
Ø over inner
Ø of armour
RT of outer
Overall
sheath
wire
sheath
diameter
approx. (mm)
nom. (mm)
nom. (mm)
approx. (mm)
Weight
Part No.
approx. (kg/km)
Outer sheath: black
1.3 mm²/7 2
0.45
1.0
11.4
0.9
1.4
16.0
440
7776R256
4
0.45
1.1
13.5
0.9
1.5
18.3
560
7776R259
5
0.45
1.1
14.8
0.9
1.5
19.6
650
7776R262
6
0.45
1.2
16.3
0.9
1.6
21.3
745
7776R265
8
0.45
1.3
17.6
1.25
1.6
23.3
995
7776R268
10
0.45
1.3
20.0
1.25
1.7
25.9
1160
7776R271
12
0.45
1.4
21.2
1.25
1.7
27.1
1280
7776R274
16
0.45
1.5
24.1
1.25
1.8
30.2
1570
7776R277
20
0.45
1.6
26.8
1.25
1.9
33.1
1840
7776R280
24
0.45
1.7
29.2
1.6
2.0
36.4
2320
7776R283
1.5 mm²/7 2
0.45
1.0
11.8
0.9
1.5
16.6
465
7776R286
4
0.45
1.1
14.0
0.9
1.5
18.8
590
7776R289
5
0.45
1.2
15.5
0.9
1.5
20.3
690
7776R292
6
0.45
1.2
16.9
1.25
1.6
22.6
900
7776R295
8
0.45
1.3
18.3
1.25
1.7
24.2
1045
7776R298
10
0.45
1.4
21.0
1.25
1.7
26.9
1245
7776R301
12
0.45
1.4
22.0
1.25
1.7
27.9
1350
7776R304
16
0.45
1.5
25.1
1.25
1.8
31.2
1670
7776R307
20
0.45
1.6
27.9
1.6
1.9
34.9
2140
7776R310
24
0.45
1.7
30.4
1.6
2.0
37.6
2460
7776R313
2.5 mm²/7 2
0.55
1.1
14.1
0.9
1.5
18.9
570
7776R966
4
0.55
1.2
16.7
1.25
1.6
22.4
900
7776R967
5
0.55
1.3
18.6
1.25
1.6
24.3
1055
7776R968
6
0.55
1.3
20.3
1.25
1.7
26.2
1200
7776R969
8
0.55
1.4
21.9
1.25
1.8
28.0
1420
7776R970
10
0.55
1.5
25.1
1.25
1.8
31.2
1685
7776R971
12
0.55
1.6
26.6
1.25
1.9
32.9
1875
7776R972
16
0.55
1.7
30.3
1.6
2.0
37.5
2530
7776R973
20
0.55
1.8
33.7
1.6
2.1
41.1
2960
7776R974
24
0.55
1.9
36.7
2.0
2.2
45.1
3750
7776R975
RT = Radial Thickness