Alpha Wire

Page 359

TECHNICAL DATA

XTRA•GUARD® 2

ENGINEERING SPECIFICATION 4.0 TEST DATA (Continued) 4.6

Aging Characteristics ASTM Method

ORIGINAL PROPERTIES Heat Stability (Air-oven 1 wk) @ 121°C @ 140°C UV Stability (Fade-o-meter) after 20 hrs. 60 hrs. 100 hrs. 200 hrs. Hydrolytic Stability Immersion @ 75°C after 2 wks. 4 wks. 6 wks. 8 wks. Immersion @ 85°C after 2 wks. 4 wks. 6 wks. 8 wks. Original Properties SERVICE FLUID IMMERSION D-471 ASTM Fuel A @ R.T. after 70 hrs. 2 wks. 4 wks. ASTM Fuel B @ R.T. after 70 hrs. 2 wks. 4 wks. ASTM Oil #1 @ 100°C after 70 hrs. 2 wks. 4 wks.

Web Site: www.alphawire.com Email: info@alphawire.com

D-412 D-573

Tensile Strength PSI

Ultimate Elongation %

100% Modulus PSI

300% Modulus PSI

Weight Change %

Volume Change %

4150

620

900

1100

3400 2000

720 790

700 600

1200 900

3850 3700 3500 3200

630 630 650 620

900 900 800 800

1200 1150 1100 1100

3600 3350 3150 2950

680 630 650 640

750 750 725 725

1100 1200 1125 1100

3000 2500 2400 1950 4150

690 640 700 620 620

650 700 650 625 900

1050 1050 1000 975 1100

3900 4100 4000

590 600 590

700 750 700

1100 1100 1100

+ 3.18 + 2.53 + 1.89

+ 6.28 + 6.04 + 5.51

2750 2750 2600

590 610 600

550 600 600

900 900 900

+ 16.27 + 14.78 + 15.60

+ 28.24 + 26.84 + 28.43

3800 3150 2825

690 710 620

700 750 725

1200 1200 1250

– 4.50 + 4.84 + 4.19

+ 1.57 + 1.94 + 0.13

349

D-1499

D-3137

Toll Free: 1-800-52 ALPHA • Telephone: 908-925-8000 • Fax: 908-925-6923 Europe/UK Telephone: +44 (0) 1932 772422 • Europe/UK Fax: +44 (0) 1932 772433