MENDOTA DXV-35 GAS DIRECT VENT FIREPLACE
SPECIFICATIONS & CLEARANCES FOR REAR VENT SYSTEM USE ONLY DURAVENT 5"X8" COAXIAL PIPES AND VENTING COMPONENTS. 31 1/2
44 7/8
11 1/16 2X4 WALL
10 7/8
4 1/8 FOR 2X4 WALLS 2 5/8 FOR 2X6 WALLS
22 1/4
19 5/8 16 1/8 15 3/8 1/2 to 2 1/2
6" LENGTH MINIMUM 9" LENGTH MAXIMUM
35 7/8 45° 10"
45 Deg L
USE A MINIMUM OF A 6" DURAVENT PIPE SECTION TO CONNECT THE REAR VENT STATER COLLAR TO THE HORIZONTAL CAP. SLIDE HORIZONTAL CAP OVER THE 6" PIPE AS FAR AS NEEDED.
44 7/8 4 1/8 FOR 2X4 WALLS 2 5/8 FOR 2X6 WALLS
MINIMUM FRAMING DIMENSIONS FOR THE DIRECT VENT Adjacent Walls: A wall, perpendicular to and in front of the appliance front facing must be at least 10" from the firebox opening. A wall at 45° to the front and starting at the appliance's outer edge is permitted. Projections behind this wall (shaded area) are permitted.
HEIGHT
WIDTH DEPTH
31-1/2 (800 mm)
37 1/8 (943 mm)
16-1/8 (410 mm)
COMBUSTIBLE MANTEL MUST REMAIN IN THIS TRIANGULAR AREA. FOR EVERY 1" INCREASE IN MANTEL DEPTH, INCREASE HEIGHT ABOVE GRILL IF DEPTH IS BY 2". MANTEL MAY BE LOWERED DECREASED IN THE SAME MANNER
1
64 1/8
CORNER INSTALLATION FOR 2x4 WALLS, USE THESE DIMENSIONS. FOR 2X6 WALLS, MOVE FIREPLACE CLOSER TO WALLS IN EACH DIRECTION 2". USE A 9" PIPE SECTION IF YOU DESIRE A WIDER DIAGONAL MEASUREMENT.
2
8" MANTEL DEPTH (WIDTH)
8" COMBUSTIBLE MANTEL
14" DISTANCE MINIMUM TO 8" MANTEL
1 5/32
8" THIMBLE & 5"X8" HORIZONTAL TERMINATION CAP
14 MIN. FROM TOP OF GRILL TO 8" MANTEL
49 1/2" MIN. CLEARANCE TO COMBUSTIBLE ABOVE UNIT & MINIMUM CEILING HEIGHT
32
43 1/8 31 1/2 31-1/2
29 22-5/8
4 5/8" GAS INLET
NON-COMBUSTIBLE HEARTH PROTECTOR REQUIRED
12" DEPTH
2 1/2" 16 1/8
36
NOTE: FOR EVERY 1" THE FIREPLACE IS RAISED OFF THE FLOOR, HEARTH PROTECTOR MAY BE REDUCED BY 2". IF FIREPLACE IS RAISED 6" OR MORE, NO HEARTH PROTECTION IS REQUIRED.
1 7/8
IF MANTEL IS MADE OF A NON-COMBUSTIBLE MATERIAL (BRICK, STONE, ETC..), OR HAS A STEEL PROTECTOR PLATE ON THE UNDERSIDE IT MAY BE PLACED ANYWHERE ABOVE GRILL
WARNING: Do not cover the 2” faceplate border of the unit with combustible materials. Figure 7: SPECIFICATIONS AND CLEARANCES FOR DXV35 REAR VENTED SYSTEM ONLY!!
NOTE:
MAXIMUM HORIZONTAL RUN ALLOWED IS 9” FOR STRAIGHT-OUT-THE-BACK AND CORNER INSTALLATIONS. ONLY THE VENT CONFIGURATIONS SHOW ABOVE ARE ALLOWED!! NOTE: WHEN INSTALLING THE DXV35 USING THE REAR VENT OPTION AT ALTITUDES ABOVE 4000 FEET, THE GAS INPUT RATE MUST BE REDUCED (DERATED) BY 4% FOR EVERY 1000 FEET
ABOVE SEA LEVEL. INSTRUCTIONS.
CONTACT YOUR GAS SUPPLIER FOR PROPER DERATING